This is a Hazardous/Regulated Materials Survey & Inspection Report prepared by Environmental Testing & Consulting, Inc. for the City of Detroit Demolition Department regarding a residential property at 14593 Burgess Street, Detroit, Michigan (Parcel #22112398). The inspection was conducted on July 31, 2026, with the report issued on August 14, 2026, in support of a planned residential demolition project (Group 9.3.26). The single-story, 851 square-foot house was built in 1963 with a cinderblock foundation. The survey identified multiple asbestos-containing materials (ACM) throughout the property, including ceiling/wall drywall composite (5,860 SF), transite siding (1,250 SF), asphalt sealant (30 LF), and exterior caulk (410 LF). The engineering survey documented structural damage including water damage affecting multiple functional spaces and holes in the roof, with several areas marked as partially or completely inaccessible. Sample collection occurred on July 31, 2026, with comprehensive laboratory analysis completed by August 5, 2026. The report includes detailed polarized light microscopy (PLM) and point count analysis results for 78 bulk samples across 26 material categories, identifying specific asbestos concentrations and locations throughout interior and exterior areas.
The laboratory analysis results confirmed the presence of asbestos-containing materials at various concentrations. Multiple samples tested positive for chrysotile asbestos, including transite siding at 5% chrysotile, exterior caulk/sealant materials ranging from trace amounts to 8% chrysotile, and certain adhesive and powdery materials. Several samples received "Positive Stop" designations, indicating confirmed asbestos presence that halted further analysis per EPA protocols. Materials with less than 1% asbestos content were classified as trace asbestos. No other hazardous materials or tires were observed at the property. The contractor is responsible for verifying all quantities of identified asbestos during the bid process. The report was prepared by licensed Michigan Asbestos Inspectors Andre Richardson (License #A45125) and reviewed by Mark Smith (License #A55707), with support from Environmental Testing Laboratories, Inc., located in Romulus, Michigan. The detailed material list and sample documentation provide contractors with comprehensive information necessary for developing safe demolition procedures and waste disposal protocols compliant with OSHA and EPA regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous/Regulated Materials Survey & Inspection Report
14593 Burgess Street, Detroit, MI 48223 Parcel #: 22112398.
Date of Inspection: 07/31/2026 Date of Report: 08/14/2026
Prepared For:
City of Detroit Demolition Department
1301 3rd Avenue, 6th Floor
Detroit, MI 48226
Project #: 2026 BPO 7.20.2026
Fieldwork conducted by: Report Reviewed and Approved by:
Andre Richardson Mark Smith Michigan Asbestos Inspector License #: A45125 Michigan Asbestos Inspector License #: A55707 Inspector’s E-Mail: Andre.Richardson@2etc.com E-Mail: Mark.Smith@2etc.com
38900 West Huron River Drive Romulus, MI 48174
734-955-6600 www.2etc.com
Hazardous/Regulated Materials Survey & Inspection Report ETC Job #: 293121
14593 Burgess Street, Detroit, MI 48223 Parcel #: 22112398.
Asbestos Containing Materials
TABLE 1: ASBESTOS CONTAINING MATERIALS
Category Material Description Location Quantity
M Ceiling/Wall Drywall Composite, White FS 1-7 5860 SF
M Transite Siding, Beige EA 1-4 1250 SF
M Asphalt Sealant, Black EA 1 30 LF
M Exterior Caulk, Beige EA 1-4 410 LF TSI = Thermal System Insulation; S = Surfacing; M = Miscellaneous; SF= Square Feet; LF = Linear Feet;
CY = Cubic Yards; CF = Cubic Feet
Quantities that are listed are estimates only. It is the contractor’s responsibility to verify all amounts of asbestos identified during the bid process.
Hazardous Materials & Tires
TABLE 2: HAZARDOUS MATERIALS
Material Description Location Quantity
None Observed
Engineering Survey
14593 Burgess Street
Reviewed 08/2025
Pre-Demolition Engineering Survey Report
Detroit, MI 48223
Prepared for City of Detroit Demolition Department
1301 Third Street, 6th Floor Detroit, Michigan 48226
Prepared by Environmental Testing & Consulting, Inc.
38900 West Huron River Drive Romulus, MI 48174
Report Date July 30, 2026
Reviewed 08/2025
Survey Details and Site Information Date(s) of Engineering Survey: July 30, 2026
Engineering Survey Inspector name: Jeremy Westcott
Engineering Survey Inspector #: INSP01045
Engineering Survey Inspector email: Jeremy.Westcott@2etc.com
Engineering Survey Inspector phone #: 734-955-6600
Engineering Survey Inspector signature:
Reviewing PE/Architect name:
Reviewing PE/Architect license state/#:
Reviewing PE/Architect email:
Reviewing PE/Architect phone #:
Reviewing PE/Architect signature:
Property Address: 14593 Burgess Street, Detroit, MI 48223
# and types of structure(s): 1 House
Foundation type Cinderblock
Year built: 1963
# of floors: 1
Total square footage: 851 ft2
William Earle, P.E. (WI)
WI 35407-6
William.Earle@oneatlas.com
847-971-0979
Reviewed 08/2025
Engineering Survey Findings – Exterior Areas Designation Inaccessible Reason Description/Notes
EA-1
EA-2
EA-3
EA-4
EA-5
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
C S Holes in roof
Reviewed 08/2025
Engineering Survey Findings – Functional Spaces Designation Inaccessible Reason Description/Notes
FS-1
FS-2
FS-3
FS-4 P W Floor is soft on EA2 side
FS-5
FS-6
FS-7 P W Floor is soft on EA2 side
FS-8 P W Floor is soft on EA2 side; exposed ceiling
FS-9
FS-10
FS-11 P W Floor is soft on EA2 side
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Site Drawings
Reviewed 08/2025
Site Photographs
EA1 EA2
EA3 EA4
Reviewed 08/2025
EA5 FS1
FS2 FS3
Reviewed 08/2025
FS4 FS5
FS6 FS7
Reviewed 08/2025
FS8 FS9
FS10 FS11
Electronic Chain of Custody
Submitting Client:
Detroit, MI - 48226
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Environmental Testing Laboratories, Inc.
City of Detroit - Demolition Department
1301 Third Street - Suite 606
Asbestos-Bulk
72 Hours
No
Yes, 400.00 Points
ETC STND
Sample Type:
Turn Around:
Positive Stop:
Point Counting:
P.C. Criteria:
Sample ID Client Sample ID
ETL Project :Project Location: 29312114593 Burgess, Detroit, MI 48223
Collection DateSample Location Sample Description
1914518 2026-07-311A FS4 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914519 2026-07-311B FS5 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914520 2026-07-311C FS6 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914521 2026-07-312A FS11 Insulation / Rolled-In - Yellow - HA(2)
1914522 2026-07-312B FS11 Insulation / Rolled-In - Yellow - HA(2)
1914523 2026-07-312C FS11 Insulation / Rolled-In - Yellow - HA(2)
1914524 2026-07-313A FS1 Concrete / Floor - Grey - HA(3)
1914525 2026-07-313B FS2 Concrete / Floor - Grey - HA(3)
1914526 2026-07-313C FS1 Concrete / Floor - Grey - HA(3)
1914527 2026-07-314A FS1 Wall (Ext.) / Window (Glazing) - White - HA(4)
1914528 2026-07-314B FS2 Wall (Ext.) / Window (Glazing) - White - HA(4)
1914529 2026-07-314C FS1 Wall (Ext.) / Window (Glazing) - White - HA(4)
1914530 2026-07-315A FS7 Floor / Tile - Brown & Grey - HA(5)
1914531 2026-07-315B FS7 Floor / Tile - Brown & Grey - HA(5)
1914532 2026-07-315C FS7 Floor / Tile - Brown & Grey - HA(5)
1914533 2026-07-316A FS7 Floor / Tile Mastic - Clear - HA(6)
1914534 2026-07-316B FS7 Floor / Tile Mastic - Clear - HA(6)
1914535 2026-07-316C FS7 Floor / Tile Mastic - Clear - HA(6)
1914536 2026-07-317A FS7 Ceramic Tile / Tile - White - HA(7)
Sample ID Client Sample ID
ETL Project :Project Location: 29312114593 Burgess, Detroit, MI 48223
Collection DateSample Location Sample Description
1914537 2026-07-317B FS7 Ceramic Tile / Tile - White - HA(7)
1914538 2026-07-317C FS7 Ceramic Tile / Tile - White - HA(7)
1914539 2026-07-318A FS7 Ceramic Tile / Adhesive - Brown - HA(8)
1914540 2026-07-318B FS7 Ceramic Tile / Adhesive - Brown - HA(8)
1914541 2026-07-318C FS7 Ceramic Tile / Adhesive - Brown - HA(8)
1914542 2026-07-319A FS10 Ceiling / Tile - White - HA(9)
1914543 2026-07-319B FS10 Ceiling / Tile - White - HA(9)
1914544 2026-07-319C FS10 Ceiling / Tile - White - HA(9)
1914545 2026-07-3110A FS10 Ceiling / Glue Pod - Brown - HA(10)
1914546 2026-07-3110B FS10 Ceiling / Glue Pod - Brown - HA(10)
1914547 2026-07-3110C FS10 Ceiling / Glue Pod - Brown - HA(10)
1914548 2026-07-3111A EA1 Concrete / Porch - Grey - HA(11)
1914549 2026-07-3111B EA1 Concrete / Porch - Grey - HA(11)
1914550 2026-07-3111C EA1 Concrete / Porch - Grey - HA(11)
1914551 2026-07-3112A EA1 Concrete / Walkway - Grey - HA(12)
1914552 2026-07-3112B EA2 Concrete / Walkway - Grey - HA(12)
1914553 2026-07-3112C EA3 Concrete / Walkway - Grey - HA(12)
1914554 2026-07-3113A EA2 Concrete / Driveway - Grey - HA(13)
1914555 2026-07-3113B EA2 Concrete / Driveway - Grey - HA(13)
1914556 2026-07-3113C EA2 Concrete / Driveway - Grey - HA(13)
1914557 2026-07-3114A EA1 Transite / Siding - Beige - HA(14)
1914558 2026-07-3114B EA2 Transite / Siding - Beige - HA(14)
1914559 2026-07-3114C EA3 Transite / Siding - Beige - HA(14)
1914560 2026-07-3115A EA1 Transite Seam-Tape - Black - HA(15)
1914561 2026-07-3115B EA2 Transite Seam-Tape - Black - HA(15)
1914562 2026-07-3115C EA3 Transite Seam-Tape - Black - HA(15)
1914563 2026-07-3116A EA1 Wall (Ext.) / Vapor Barrier - Black - HA(16)
1914564 2026-07-3116B EA2 Wall (Ext.) / Vapor Barrier - Black - HA(16)
Collection DateSample Location Sample Description
1914565 2026-07-3116C EA3 Wall (Ext.) / Vapor Barrier - Black - HA(16)
1914566 2026-07-3117A EA1 Concrete / Wall - Grey - HA(17)
1914567 2026-07-3117B EA2 Concrete / Wall - Grey - HA(17)
1914568 2026-07-3117C EA3 Concrete / Wall - Grey - HA(17)
1914569 2026-07-3118A EA1 Wall (Ext.) / Brick - Grey - HA(18)
1914570 2026-07-3118B EA1 Wall (Ext.) / Brick - Grey - HA(18)
1914571 2026-07-3118C EA1 Wall (Ext.) / Brick - Grey - HA(18)
1914572 2026-07-3119A EA1 Caulk / Exterior - Brown - HA(19)
1914573 2026-07-3119B EA2 Caulk / Exterior - Brown - HA(19)
1914574 2026-07-3119C EA3 Caulk / Exterior - Brown - HA(19)
1914575 2026-07-3120A EA1 Caulk / Exterior - Black - HA(20)
1914576 2026-07-3120B EA2 Caulk / Exterior - Black - HA(20)
1914577 2026-07-3120C EA3 Caulk / Exterior - Black - HA(20)
1914578 2026-07-3121A EA1 Asphalt Sealant - Black - HA(21)
1914579 2026-07-3121B EA1 Asphalt Sealant - Black - HA(21)
1914580 2026-07-3121C EA1 Asphalt Sealant - Black - HA(21)
1914581 2026-07-3122A EA1 Cinderblock - Grey - HA(22)
1914582 2026-07-3122B EA1 Cinderblock - Grey - HA(22)
1914583 2026-07-3122C EA1 Cinderblock - Grey - HA(22)
1914584 2026-07-3123A EA1 Mortar / Cinderblock - Grey - HA(23)
1914585 2026-07-3123B EA1 Mortar / Cinderblock - Grey - HA(23)
1914586 2026-07-3123C EA1 Mortar / Cinderblock - Grey - HA(23)
1914587 2026-07-3124A EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914588 2026-07-3124B EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914589 2026-07-3124C EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914590 2026-07-3125A EA5 Roofing / Tar Paper - Black - HA(25)
1914591 2026-07-3125B EA5 Roofing / Tar Paper - Black - HA(25)
1914592 2026-07-3125C EA5 Roofing / Tar Paper - Black - HA(25)
Collection DateSample Location Sample Description
1914593 2026-07-3126A EA1 Caulk / Exterior - Beige - HA(26)
1914594 2026-07-3126B EA2 Caulk / Exterior - Beige - HA(26)
1914595 2026-07-3126C EA3 Caulk / Exterior - Beige - HA(26)
Seal Intact:
Preservative (if required):
Containers Labled :
Yes
Yes
Analyst
Yes
Collection DateSample Location Sample Description
Received By:
Received Date:
Relinquished By:
Relinquished Date:
James Farinas
2026-07-31 09:49 AM
Andre Richardson
Jul 31 2026 12:00AM Asha Davidson
Ben Jones
Chris Canilao
OJ Ivey
Teagan Murphy
Tia Ray
Material List
Client : City of Detroit - Demolition Department 1301 Third Street - Suite 606 Detroit, MI - 48226
Project Location: 14593 Burgess st. Detroit Mi. Job #:293121
Material Id Material Description Material Sub Classification Size Quantity Locations
1 Ceiling / Wall/D rywall Composite-White Drywall Composite M 5860 S F F S-01,F S-02,F S-03,F S-04,F S-05,F S-06,F S-07
2 Insulation/Rolled-In-Yellow Rolled-In T 798 S F F S-11
3 Concrete/F loor-Grey F loor M 790 S F F S-01,F S-02
4 Wall (Ext.)/Window (Glazing)-White Window (Glazing) M 7 Unit E A-01,E A-02,E A-03,E A-04
5 F loor/Ti le-B rown & Grey Tile M 68 S F F S-07
6 F loor/Ti le Mastic-C lear Ti le Mastic M 68 S F F S-07
7 Ceramic Ti le/Ti le-White Ti le M 97 S F F S-07
8 Ceramic Ti le/Adhesive-Brown Adhesive M 97 S F F S-07
9 Ceiling/Ti le-White Ti le M 185 S F F S-10
10 Ceiling/Glue Pod-Brown Glue Pod M 185 S F F S-10
11 Concrete/Porch-Grey Porch M 25 S F E A-01
12 Concrete/Walkway-Grey Walkway M 185 S F E A-01,E A-02,E A-03,E A-04
13 Concrete/D riveway-Grey Driveway M 650 S F E A-02
14 Transite/S iding-Beige S iding M 1250 S F E A-02,E A-03,E A-01,E A-04
15 Transite Seam-Tape-B lack M 1250
16 Wall (Ext.)/Vapor Barrier-B lack Vapor Barrier M 1250 S F E A-01,E A-02,E A-03,E A-04
17 Concrete/Wall-Grey Wall M 980 S F E A-01,E A-02,E A-03,E A-04
18 Wall (Ext.)/B rick-Grey Brick M 89 S F E A-01
19 Caulk/Exterior-B rown Exterior M 285 LF E A-01,E A-02,E A-03,E A-04
20 Caulk/Exterior-B lack Exterior M 290 LF E A-01,E A-02,E A-03,E A-04
21 Asphalt Sealant-B lack M 30 LF E A-01
22 C inderblock-Grey M 50 S F E A-09,E A-01
23 Mortar/C inderblock-Grey C inderblock M 50 S F E A-01
24 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 990 S F E A-05
25 Roofing/Tar Paper-B lack Tar Paper M 990 S F E A-05
26 Caulk/Exterior-Beige Exterior M 410 LF E A-01,E A-02,E A-03,E A-04
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Environmental Testing And Consulting Inc.
38900 Huron River Drive
Romulus, MI 48174
Project Location: 14593 Burgess, Detroit, MI 48223
Client Project: 293121
293121ETL Job:
Al Dyer
Report Issued: 08/05/2026
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1914518 Asbestos1A 08/05/2026 Asha Davidson07/31/2026
1914519 Asbestos1B 08/05/2026 Asha Davidson07/31/2026
1914520 Asbestos1C 08/05/2026 Asha Davidson07/31/2026
1914521 Asbestos2A 08/05/2026 Asha Davidson07/31/2026
1914522 Asbestos2B 08/05/2026 Asha Davidson07/31/2026
1914523 Asbestos2C 08/05/2026 Asha Davidson07/31/2026
1914524 Asbestos3A 08/05/2026 Asha Davidson07/31/2026
1914525 Asbestos3B 08/05/2026 Asha Davidson07/31/2026
1914526 Asbestos3C 08/05/2026 Asha Davidson07/31/2026
1914527 Asbestos4A 08/05/2026 Teagan Murphy07/31/2026
1914528 Asbestos4B 08/05/2026 Teagan Murphy07/31/2026
1914529 Asbestos4C 08/05/2026 Teagan Murphy07/31/2026
1914530 Asbestos5A 08/05/2026 Teagan Murphy07/31/2026
1914531 Asbestos5B 08/05/2026 Teagan Murphy07/31/2026
1914532 Asbestos5C 08/05/2026 Teagan Murphy07/31/2026
1914533 Asbestos6A 08/05/2026 Teagan Murphy07/31/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1914534 Asbestos6B 08/05/2026 Teagan Murphy07/31/2026
1914535 Asbestos6C 08/05/2026 Teagan Murphy07/31/2026
1914536 Asbestos7A 08/05/2026 Teagan Murphy07/31/2026
1914537 Asbestos7B 08/05/2026 Teagan Murphy07/31/2026
1914538 Asbestos7C 08/05/2026 Teagan Murphy07/31/2026
1914539 Asbestos8A 08/05/2026 Teagan Murphy07/31/2026
1914540 Asbestos8B 08/05/2026 Teagan Murphy07/31/2026
1914541 Asbestos8C 08/05/2026 Teagan Murphy07/31/2026
1914542 Asbestos9A 08/05/2026 Teagan Murphy07/31/2026
1914543 Asbestos9B 08/05/2026 Teagan Murphy07/31/2026
1914544 Asbestos9C 08/05/2026 Teagan Murphy07/31/2026
1914545 Asbestos10A 08/05/2026 Teagan Murphy07/31/2026
1914546 Asbestos10B 08/05/2026 Teagan Murphy07/31/2026
1914547 Asbestos10C 08/05/2026 Teagan Murphy07/31/2026
1914548 Asbestos11A 08/05/2026 Chris Canilao07/31/2026
1914549 Asbestos11B 08/05/2026 Chris Canilao07/31/2026
1914550 Asbestos11C 08/05/2026 Chris Canilao07/31/2026
1914551 Asbestos12A 08/05/2026 Chris Canilao07/31/2026
1914552 Asbestos12B 08/05/2026 Chris Canilao07/31/2026
1914553 Asbestos12C 08/05/2026 Chris Canilao07/31/2026
1914554 Asbestos13A 08/05/2026 Chris Canilao07/31/2026
1914555 Asbestos13B 08/05/2026 Chris Canilao07/31/2026
1914556 Asbestos13C 08/05/2026 Chris Canilao07/31/2026
1914557 Asbestos14A 08/05/2026 Ben Jones07/31/2026
1914558 Asbestos14B 08/05/2026 Ben Jones07/31/2026
1914559 Asbestos14C 08/05/2026 Ben Jones07/31/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1914560 Asbestos15A 08/05/2026 Ben Jones07/31/2026
1914561 Asbestos15B 08/05/2026 Ben Jones07/31/2026
1914562 Asbestos15C 08/05/2026 Ben Jones07/31/2026
1914563 Asbestos16A 08/05/2026 Ben Jones07/31/2026
1914564 Asbestos16B 08/05/2026 Ben Jones07/31/2026
1914565 Asbestos16C 08/05/2026 Ben Jones07/31/2026
1914566 Asbestos17A 08/05/2026 Tia Ray07/31/2026
1914567 Asbestos17B 08/05/2026 Tia Ray07/31/2026
1914568 Asbestos17C 08/05/2026 Tia Ray07/31/2026
1914569 Asbestos18A 08/05/2026 Tia Ray07/31/2026
1914570 Asbestos18B 08/05/2026 Tia Ray07/31/2026
1914571 Asbestos18C 08/05/2026 Tia Ray07/31/2026
1914572 Asbestos19A 08/05/2026 Tia Ray07/31/2026
1914573 Asbestos19B 08/05/2026 Tia Ray07/31/2026
1914574 Asbestos19C 08/05/2026 Tia Ray07/31/2026
1914575 Asbestos20A 08/05/2026 Asha Davidson07/31/2026
1914576 Asbestos20B 08/05/2026 Asha Davidson07/31/2026
1914577 Asbestos20C 08/05/2026 Asha Davidson07/31/2026
1914578 Asbestos21A 08/05/2026 Asha Davidson07/31/2026
1914579 Asbestos21B 08/05/2026 Asha Davidson07/31/2026
1914580 Asbestos21C 08/05/2026 Asha Davidson07/31/2026
1914581 Asbestos22A 08/05/2026 Asha Davidson07/31/2026
1914582 Asbestos22B 08/05/2026 Asha Davidson07/31/2026
1914583 Asbestos22C 08/05/2026 Asha Davidson07/31/2026
1914584 Asbestos23A 08/05/2026 Asha Davidson07/31/2026
1914585 Asbestos23B 08/05/2026 Asha Davidson07/31/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1914586 Asbestos23C 08/05/2026 Asha Davidson07/31/2026
1914587 Asbestos24A 08/05/2026 OJ Ivey07/31/2026
1914588 Asbestos24B 08/05/2026 OJ Ivey07/31/2026
1914589 Asbestos24C 08/05/2026 OJ Ivey07/31/2026
1914590 Asbestos25A 08/05/2026 OJ Ivey07/31/2026
1914591 Asbestos25B 08/05/2026 OJ Ivey07/31/2026
1914592 Asbestos25C 08/05/2026 OJ Ivey07/31/2026
1914593 Asbestos26A 08/05/2026 OJ Ivey07/31/2026
1914594 Asbestos26B 08/05/2026 OJ Ivey07/31/2026
1914595 Asbestos26C 08/05/2026 OJ Ivey07/31/2026
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 78 8
Point Count 5
Dawson Bradley
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914518
1A PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM 2% Chrysotile1914518
1A PLM 98% OtherPLM Trace CelluloseWhiteMud
Non-Fibrous
HomogenousFS4
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914518
1A PLM 5% OtherPLM 95% CelluloseRedPaper Backing
Fibrous
HomogenousFS4
Layer-3 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914519
1B PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS5
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
1914519
1B
Positive Stop
FS5
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
Layer Not Analyzed
PLM None Detected 1914519
1B PLM 5% OtherPLM 95% CelluloseRedPaper Backing
Fibrous
HomogenousFS5
Layer-3 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914520
1C PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
1914520
1C
Positive Stop
FS6
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
Layer Not Analyzed
PLM None Detected 1914520
1C PLM 5% OtherPLM 95% CelluloseRedPaper Backing
Fibrous
HomogenousFS6
Layer-3 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914521
2A PLM 5% OtherPLM 95% CelluloseYellow/WhiteInsulation / Rolled-In - Yellow -
HA(2) Fibrous
Non-HomogenousFS11
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
With Fibrous Material
PLM None Detected 1914521
2A PLM 5% OtherPLM 95% CelluloseBlackFibrous Backing
Fibrous
HomogenousFS11
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914522
2B PLM 5% OtherPLM 95% CelluloseYellowInsulation / Rolled-In - Yellow -
HA(2) Fibrous
HomogenousFS11
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914522
2B PLM 5% OtherPLM 95% CelluloseBlackFibrous Backing
Fibrous
HomogenousFS11
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914523
2C PLM 5% OtherPLM 95% CelluloseYellowInsulation / Rolled-In - Yellow -
HA(2) Fibrous
HomogenousFS11
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914523
2C PLM 5% OtherPLM 95% CelluloseBlackFibrous Backing
Fibrous
HomogenousFS11
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914524
3A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(3)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PLM None Detected 1914525
3B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(3)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914526
3C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(3)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/05/2026
PC 0.25% Chrysotile1914527
4A PC 99.75% OtherWhiteWall (Ext.) / Window (Glazing) -
White - HA(4) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PC Trace Chrysotile1914528
4B PC 100% OtherWhiteWall (Ext.) / Window (Glazing) -
White - HA(4) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PC Trace Chrysotile1914529
4C PC 100% OtherWhiteWall (Ext.) / Window (Glazing) -
White - HA(4) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914530
5A PLM 100% OtherBrown/GreyFloor / Tile - Brown & Grey -
HA(5) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914531
5B PLM 100% OtherBrown/GreyFloor / Tile - Brown & Grey -
HA(5) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914532
5C PLM 100% OtherBrown/GreyFloor / Tile - Brown & Grey -
HA(5) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914533
6A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(6) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914534
6B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(6) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914535
6C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(6) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914535
6C PLM 98% OtherPLM 2% CelluloseWhitePowdery Material
Non-Fibrous
HomogenousFS7
Layer-2 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914536
7A PLM 99% Ceramic
PLM 1% Other
WhiteCeramic Tile / Tile - White -
HA(7) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914536
7A PLM 99% OtherPLM 1% CelluloseWhiteGrout
Non-Fibrous
HomogenousFS7
Layer-2 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914537
7B PLM 99% Ceramic
PLM 1% Other
WhiteCeramic Tile / Tile - White -
HA(7) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914538
7C PLM 99% Ceramic
PLM 1% Other
WhiteCeramic Tile / Tile - White -
HA(7) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914539
8A PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile / Adhesive - Brown
- HA(8) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914540
8B PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile / Adhesive - Brown
- HA(8) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PC Trace Chrysotile1914540
8B PC 100% OtherBeigePowdery Material
Non-Fibrous
HomogenousFS7
Layer-2 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914541
8C PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile / Adhesive - Brown
- HA(8) Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PC 0.25% Chrysotile1914541
8C PC 99.75% OtherBeigePowdery Material
Non-Fibrous
HomogenousFS7
Layer-2 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914541
8C PLM 2% OtherPLM 98% CelluloseBeigeFibrous Material
Fibrous
HomogenousFS7
Layer-3 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914542
9A PLM 8% OtherPLM 92% Mineral woolWhiteCeiling / Tile - White - HA(9)
Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914543
9B PLM 8% OtherPLM 92% Mineral woolWhiteCeiling / Tile - White - HA(9)
Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914544
9C PLM 8% OtherPLM 92% Mineral woolWhiteCeiling / Tile - White - HA(9)
Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914545
10A PLM 99% OtherPLM 1% CelluloseBrownCeiling / Glue Pod - Brown -
HA(10) Non-Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914546
10B PLM 99% OtherPLM 1% CelluloseBrownCeiling / Glue Pod - Brown -
HA(10) Non-Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914547
10C PLM 99% OtherPLM 1% CelluloseBrownCeiling / Glue Pod - Brown -
HA(10) Non-Fibrous
HomogenousFS10
Layer-1 Analyst: Teagan Murphy
Date Analyzed : 08/05/2026
PLM None Detected 1914548
11A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(11)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914549
11B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(11)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914550
11C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(11)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914551
12A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(12) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914552
12B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(12) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914553
12C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(12) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914554
13A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(13) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914555
13B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(13) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM None Detected 1914556
13C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(13) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/05/2026
PLM 5% Chrysotile1914557
14A PLM 95% OtherPLM Trace CelluloseBeigeTransite / Siding - Beige -
HA(14) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
1914558
14B
Positive Stop
EA2
Analyst: Ben Jones
Date Analyzed : 08/05/2026
Sample Not Analyzed
1914559
14C
Positive Stop
EA3
Analyst: Ben Jones
Date Analyzed : 08/05/2026
Sample Not Analyzed
PLM None Detected 1914560
15A PLM 8% OtherPLM 92% CelluloseBlackTransite Seam-Tape - Black -
HA(15) Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914561
15B PLM 8% OtherPLM 92% CelluloseBlackTransite Seam-Tape - Black -
HA(15) Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914562
15C PLM 8% OtherPLM 92% CelluloseBlackTransite Seam-Tape - Black -
HA(15) Fibrous
HomogenousEA3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914563
16A PLM 9% OtherPLM 91% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(16) Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914564
16B PLM 9% OtherPLM 91% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(16) Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914565
16C PLM 9% OtherPLM 91% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(16) Fibrous
HomogenousEA3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914566
17A PLM 100% OtherGreyConcrete / Wall - Grey - HA(17)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Tia Ray
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/31/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914567
17B PLM 100% OtherGreyConcrete / Wall - Grey - HA(17)
Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Tia Ray
Date Analyzed : 08/05/2026
PLM None Detected 1914568
17C PLM 100% OtherGreyConcrete / Wall - Grey - HA(17)
Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Tia Ray
Date Analyzed : 08/05/2026
PLM None Detected 1914569
18A PLM 100% OtherGreyWall (Ext.) / Brick - Grey -
HA(18) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Tia Ray
Date Analyzed : 08/05/2026
PLM None Detected 1914569
18A PLM 97% OtherPLM 3% CelluloseTanAdhesive
Non-Fibrous
HomogenousEA1
Layer-2 Analyst: Tia Ray
Date Analyzed : 08/05/2026
PLM None Detected 1914570
18B PLM 100% OtherGreyWall (Ext.) / Brick - Grey -
HA(18) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Tia Ray
Date Analyzed : 08/05/2026
PLM None Detected 1914570
18B PLM 98% OtherPLM 2% CelluloseTanAdhesive
Non-Fibrous
HomogenousEA1
Layer-2 Analyst: Tia Ray
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14593 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293121
293121