Attachment_9_Amendment_No_0004_0004.pdf

PDF 631 KB Posted

Attached to
FKC Middle Reach Capacity Correction Project Phase Federal contract opportunity
Solicitation number
140R2020R0009
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document provides specifications for reinforcement steel for a federal construction project. The specifications outline requirements for spacing of bars, splicing of reinforcement, and bending or straightening of reinforcement. Bars must be spaced at least 1.5 times their diameter or maximum aggregate size, and at least 1.5 inches apart. When placed in multiple layers, bars must have at least one inch or one diameter of clear spacing between layers. Splices are only permitted at indicated locations, and splice lengths must meet minimum ACI 318 Class B requirements or, for structures supporting public roadways, AASHTO LRFD specifications. Welded wire reinforcement laps must also meet ACI 318, with adjoining sheets securely tied with tie wire. Bends in reinforcement should not damage the material. The related federal contract opportunity is for the FKC Middle Reach Capacity Correction Project Phase 1, solicited by the Department of the Interior Bureau of Reclamation.

View the file

Other files for this federal contract opportunity

Other files attached to FKC Middle Reach Capacity Correction Project Phase, newest first.
File Type Posted
Attachment_1_Amendment_0007_0007.pdf PDF
Attachment_9_Amendment_0006_0006.pdf PDF
Attachment_4_Amendment_0006_0006.pdf PDF
Amendment_0006_for_Solicitation_140R2020R0009_0006.pdf PDF
Amendment_0005_for_Solicitation_140R2020R0009_0005.pdf PDF
Attachment_39_Amendment_No_0005_0005.pdf PDF
Attachment_38_Amendment_No__0005_0005.pdf PDF
Attachment_31_Amendment_No__0005_0005.pdf PDF
Attachment_25_Amendment_No__0005_0005.pdf PDF
Attachment_24_Amendment_No__0005_0005.pdf PDF
Attachment_22_Amendment_No__0005_0005.pdf PDF
Attachment_21_Amendment_No__0005_0005.pdf PDF
Attachment_20_Amendment_No__0005_0005.pdf PDF
Attachment_18_Amendment_No__0005_0005.pdf PDF
Attachment_16_Amendment_No__0005_0005.pdf PDF
Attachment_13_Amendment_No__0005_0005.pdf PDF
Attachment_6_Amendment_No_0005_0005.pdf PDF
Attachment_3_Amendment_No_0005_0005.pdf PDF
Sol_140R2020R0009_Amd_0005.pdf PDF
Attachment_26_Amendment_No__0004_0004.pdf PDF
Attachment_18_Amendment_No__0004_0004.pdf PDF
Attachment_17_Amendment_No__0004_0004.pdf PDF
Attachment_11_Amendment_No_0004_0004.pdf PDF
Attachment_4_Amendment_No_0004_0004.pdf PDF
Attachment_1_Amendment_No_0004_0004.pdf PDF
Sol_140R2020R0009_Amd_0004.pdf PDF
Drawing_C-302_Attachment_13_Amendment_No__0003_0003.pdf PDF
Drawing_C-208_Attachment_10_Amendment_No__0003_0003.pdf PDF
Drawing_C-207_Attachment_9_Amendment_No__0003_0003.pdf PDF
Drawing_C-206_Attachment_8_Amendment_No__0003_0003.pdf PDF
Sol_140R2020R0009_Amd_0003.pdf PDF
GC-09-REV-1_Att_4_Amendment_No__0002_0002.pdf PDF
Attachment_No__1_-_FKC_Pre-Proposal_Presentation_Slides_0002.pdf PDF
Attachment_5_-_PPI_Data_Revised_0002.xlsx XLSX spreadsheet
Attachment_B_1_Amendment_No_0002_0002.xlsx XLSX spreadsheet
General_Decision_Number_CA20210020_0002.pdf PDF
Attachment_No__3_-_FKC_Site_Visit_Agenda_and_Sign_in_Sheet_0002.pdf PDF
Solicitation No.140R2020R0009 Amendment No 0001_0001.pdf PDF
Sol_140R2020R0009_Amd_0001.pdf PDF
Attachment 1 - General Decision Number CA CA2021000.pdf PDF
Attachment B.1 Schedule of Prices.xlsx XLSX spreadsheet
Attachment 13 - Drawing Part 5 of 5.pdf PDF
Attachment 10 Electronic Proposal Submission.pdf PDF
Attachment 6 - RAC 15-13 Invoicing Documents.pdf PDF
Attachment 13 - Drawing Part 4 of 5.pdf PDF
Attachment 13 - Drawing Part 2 of 5.pdf PDF
Attachment 11 - Geotechnical Data Report Friant-Kern Canal Middle Reach Capacity Correction Project.pdf PDF
Attachment 8 - Key Personnel.pdf PDF
Attachment 7- Release of Claims.pdf PDF
Sol_140R2020R0009.pdf PDF
Show all 50

FKC Middle Reach Capacity Correction Project Phase has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation No: 140R2020R0009 Specifications No. 20-C0907

3.4 SPACING OF BARS

A. The clear distance between parallel bars (except between multiple layers of bars in beams or girders) shall be not less than 1-1/2 times the nominal diameter of the bars, nor less than 1- 1/2 times the maximum size of the coarse aggregate, nor less than 1- 1/2 inch.

B. Where reinforcement in beams or girders is placed in 2 or more layers, the clear distance between layers shall be not less than one inch or the nominal diameter of the bars, whichever is greater.

C. The clear distance between bars shall also apply to the distance between a contact splice and adjacent splices or bars.

3.5 SPLICING

A. General

1. Reinforcement bar splices shall only be used at indicated locations.

2. When it is necessary to splice reinforcement at points other than where indicated, the character of the splice shall be as reviewed and accepted by the CONTRACTING

OFFICERS REPRESENTATIVE.

When is it necessary or preferred for constructability to splice reinforcement at points other than where indicated, the character of the splice shall be as shown on the Structural Standard Notes and Details (GS Drawings). All proposed splice locations shall be shown and detailed on the reinforcement shop drawings.

3. Unless otherwise indicated, dowels shall match the size and spacing of the spliced bar.

B. Splices of Reinforcement

1. The length of lap for reinforcement bars, unless otherwise indicated, shall be in accordance with ACI 318 for a Class B splice.

2. Length of lap for reinforcement bars for structures supporting loads from public roadways shall be in accordance with the more strict requirements of ACI 318 and AASHTO LRFD Bridge Design Specifications for a Class B Splice.

3. Welded Wire Reinforcement

a. Laps of welded wire reinforcement shall be in accordance with ACI 318.

b. Adjoining sheets shall be securely tied together with No. 14 tie wire, one tie for each 2 running feet.

c. Wires shall be staggered and tied in such a manner that they cannot slip.

4. Splices in column spiral reinforcement, when necessary, shall be made by welding or by a lap of 1-1/2 turns.

C. Bending or Straightening

1. Reinforcement shall not be straightened or re-bent in a manner which will injure the material.

STANTEC/184031016 REINFORCEMENT STEEL

FKC MIDDLE REACH CAPACITY CORRECTION PROJECT PHASE 1 PAGE 03 21 00 - 8