Prior_Report_-_East_Tank_-_Redacted_0001.pdf
PDF 2 MB Posted
- Solicitation number
- 140P9724Q0013
About this file
This document contains a report on the inspection of a water storage tank for the National Park Service. The inspection assessed the condition of coatings and structure on a 110,000 gallon drinking water tank.
The report details observations from interior and exterior inspections, including the roof, shell, foundation, manholes, ladders, overflow pipes and vents. The interior was inspected using a remotely operated vehicle. The report notes minor issues such as staining, missing nut caps and damage to an interior ladder. Recommendations include installing a safety climb system and locking ladder guard for security. The tank is recommended for reinspection in 2024.
The related federal contract opportunity is a solicitation from the Department of the Interior National Park Service Alaska Region to clean and inspect water storage tanks. No further details are provided on products, services, pricing or response dates.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Map_0001.pdf | ||
| Picture_1_0001.pdf | ||
| Q_A_Amend_01_0001.pdf | ||
| Sol_140P9724Q0013_Amd_0001.pdf | ||
| Picture_2_0001.pdf | ||
| Prior_Report_-_West_Tank_-_Redacted_0001.pdf | ||
| Sol_140P9724Q0013.pdf | ||
| A04_SOW.pdf | ||
| DOL_WD_2015-5685_Rev_21.pdf | ||
| B08_RFQ_Content.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
East Tank
Report No. 14077-FOR-01-1
Prepared For:
National Park Service 1849 C Street NW
Washington, DC 20240
9/25/2019
STATEMENT OF LIMITATION
The conclusions presented in this document are based on the services described and not on tasks or procedures beyond the scope of the described procedures or the time and budgetary constraints imposed by the contract limitations.
. has performed this assessment in a professional manner using that degree of skill and care exercised for similar projects under similar conditions by reputable and competent consultants, and in accordance with the procedures established within quality assurance, quality control protocol.
. shall not be responsible for conditions or consequences arising from relevant facts that were concealed, withheld or not fully disclosed at the time the evaluation was performed.
Report Prepared by:
Report Reviewed by: Technical Director NACE CIP Level 3 #050
TABLE OF CONTENTS
INTRODUCTION
APPLICABLE STANDARDS
EXECUTIVE SUMMARY
OBSERVATIONS
RECOMMENDATIONS
APPENDIX I
Photographs
GLOSSARY OF TERMS
National Park Service East Tank 14077-FOR-01-1 1
INTRODUCTION
On September 25, 2019 representatives, performed a corrosion and structural assessment of the exterior and interior of a drinking water storage tank for National Park Service. The inspection was conducted to establish the current condition of the tank's coatings and steel/concrete substrate. The tank inspected included:
110,000 Gallon East Aquastore Tank
For applicable standards used in this inspection, please see below.
The interior of the reservoir was inspected with the TankRover remotely operated vehicle, while full. The TankRover is the only piece of equipment like it in the United States and was developed by . By using the TankRover the interior of the tank was inspected with no special preparation, confined space entry, no additional disinfection and no downtime.
The TankRover is equipped with a surface-cleaning tool used to remove loose rust or debris in order to view the potential metal loss under the coating. The unit has high-powered thrusters, which are used to maneuver throughout the tank and are used to wash away bottom sediment for observations. Video is recorded with audio narration on site with digital stills captured for the report.
The TankRover and all tether were prepared for the inspection by disinfecting equipment with a 200 ppm chlorine spray in accordance with AWWA C652-11.
The exterior portions of the tank were inspected by walking the roof and shell portions that were accessible from the ground.
The objectives of the assessment were to:
1. Perform field inspections and tests to assess the structural integrity of the tank.
2. Assess condition of any protective coatings present
3. Review the safety compliance of tank ladders and access.
4. Review sanitary protection equipment
5. Provide recommendations for rehabilitation.
APPLICABLE STANDARDS
AWWA C652, AWWA Standard for Disinfection of Water-Storage Facilities AWWA D103, AWWA Standard for Bolted Fused Glass Steel Tanks for Water Storage AWWA D101, AWWA Standard for Inspection of Finished Water Storage Tanks AWWA M42, AWWA Tank Guidance Manual, Steel Water Storage Tanks
National Park Service East Tank 14077-FOR-01-1 2
EXECUTIVE SUMMARY
The condition and recommendations for the tank are briefly summarized in this section. For detailed information regarding detailed tank conditions and the specific recommendations please refer to the designated section for the tank.
A safety climb system should be installed on any ladder that is 20-ft long or more. For new fixed ladders erected on or after November 19, 2018, the employer must equip the ladder with a ladder safety or personal fall arrest system (1910.28(b)(9)(i)(B)).
Based on water industry vulnerability assessments tank ladders should be no closer than 16-ft above grade and should be fitted with a locking guard. Roof hatch should be secured with a lock.
When tank is emptied for interior work the interior ladder should be removed.
Ice stress on the ladder has broken it and may stress the tank shell and cause leaks.
Tank was cleaned as part of the inspection to remove soft floor sediment.
Tank should be re-inspected in 2024.
National Park Service East Tank 14077-FOR-01-1 3
TANK DATA FOR East Tank
Site Information Fencing In Place:
Yes Locks on Gates: Yes
Address: Park Rd, Gustavus AK Vault Lock in Place: N/A
Tank Information Tank Name: East Tank Tank Diameter: 25-ft
Tank Height: 29-ft Tank Capacity:
108,000 Gallons
Previous Cleaning Date: 2014
Previous Inspect. Date: 2014 Previous Coating Application: N/A
Foundation Height: 0-in to 6-in Adequate Drainage:
no Chime Plate Size: UNK
# of Anchors: 15 Anchor Bolt Diameter: 1.25-in Chair Thickness .75-in
Anchor Chair Dimensions: 7-in x 4-in
Shell Manhole # of Manholes 1 Diameter: 24-in
Ladder Height from Ground: 6-ft Safety Cage: YES
Anti Climb Lock : N/A Climbing Safety System Style: N/A
Rung to Rung Dim: 14-in Distance from Shell: 7-in Width: 14-in
Overflow Diameter: 4.5-in Air Gap 6-in Overflow Protection Yes
Screen Condition: Intact Screen Type:
Fine Mesh Splash Pad NO
Roof Hatch Dimensions: 25-in Diameter Sanitary Neck 2-in
# of Hatches: 1 Hatch Cover Overlap
1-in Lock No
Roof Vent Style: Mushroom Diameter: 24-in
Cap to Roof Distance:
7-in Screen Condition:
Intact Type:
Fine Mesh and Coarse Screen
Roof Handrail Hts Top Rail: 42 Mid Rail: 22 Toe Kick Plate:
Interior Sediment Depth: 1/8th-in Sediment Coverage: Evenly dispersed
Inlet/Outlet Pipe: Separate Sediment Ring:
Yes
Interior Ladder Climbing Safety System: Yes, broken Style: N/A
Columns: NO Column Number: N/A Interior Column Style
N/A
National Park Service East Tank 14077-FOR-01-1 4
OBSERVATIONS
Photos provided in the report were created from a digital camera and interior pictures were captured in digital format from the interior video. The interior images are as clear as our printed technology will allow. The copies in the report provide a reference for our comments. Keep in mind that for underwater video snaps, the video provides the greatest detail and should be viewed as part of the report.
Narration on the video is done in the field and some of the comments may be different than the written report.
INTERIOR
Roof Structure
The roof is a rafter supported bolted roof. Galvanized rafters are on the interior of the roof and show no deterioration of the galvanized coating.
Roof Coating
No noticeable corrosion was seen on the roof panels or the interior structures. The caulking appears to be in good condition.
Shell Coating
The tank is coated with fused glass. No corrosion was noted on the plates themselves. Several bolt heads had minor corrosion. Sediment staining was mild.
Columns
No interior columns are installed on the tank.
Floor Structure
No bowing or settlement was noted on the floor of the tank. Nut caps were missing on several bolts.
Sediment
A fine sediment was noted on the floor of the tank and was estimated to be about 1/8th of an inch. After the inspection, the sediment was robotically cleaned off the floor.
Floor Coating
The glass fused floor is in good condition.
National Park Service East Tank 14077-FOR-01-1 5
Piping
An interior overflow pipe runs from above the fluctuation zone through the floor of the tank.
Damage was noted on the brackets holding it to the shell. The tank has a raised inlet pipe extending approximately halfway up the shell. The outlet pipe has a sediment ring installed and there is also a drain located on the floor.
Ladder
Interior ladder is damaged in two locations. Damage appears to be from ice impact or stress.
EXTERIOR
Foundation
No major cracking or spalls were noted on the foundation of the tank. The chime is inset into the foundation allowing water to pool. The anchor bolts are not fully engaged with nuts flush.
Manholes
The manhole does not show any signs of leaking. No corrosion was noted on the manhole
Ladder
Ladder is in good condition. No anti-climb or safety climb is installed on the tank.
Overflow
The overflow is internal; the pipe exits the ground next to the access road and has a fine mesh screen installed.
Shell Structure
Shell is in good condition. None of the nut caps are left on the shell of the tank or the roof.
Caulking is weathering leaving some exposed edges on the plate
Shell Coating
Minor bio-staining was noted on the shell of the tank. The tank is glass fused, no mechanical damage was noted.
Roof Hatch
The roof hatch is in good condition and has a positive pressure seal against a gasket. The hatch is not locked.
Roof Vent
Vent is in good condition and has coarse and fine mesh screen installed.
National Park Service East Tank 14077-FOR-01-1 6
Hand Rails
The roof is fully enclosed by a railing system. No damage was noted in the railings.
Roof Structure
Roof structure is in good condition.
Roof Coating
Roof coating is in good condition. Minor bio-staining was noted and debris from nearby trees.
Caulking on the roof seams is weathering exposing edges of the plates in some areas.
RECOMMENDATIONS
Ladder Safety Climb A safety climb system should be installed on any ladder that is 20-ft long or more. For new fixed ladders erected on or after November 19, 2018, the employer must equip the ladder with a ladder safety or personal fall arrest system (1910.28(b)(9)(i)(B)). Installing a cable type safety climb system will keep your tank current with OSHA standards and the device is less tiring to use than a notch railed type device. It is not recommended to use these devices on internal underwater ladders. Underwater galvanic corrosion is caused between the cable and tank making the safety device unsafe after a few years.
Locking Ladder Guard Based on water industry vulnerability assessments tank ladders should be no closer than 16-ft above grade and should be fitted with a locking guard. Installing an 8-ft ladder guard is advised for security to the tank. The most vulnerable location on the tank for vandalism is the roof.
Unwanted access to the roof can be prevented by installing a ladder guard.
Roof hatch should be secured with a lock.
When tank is emptied for interior work the interior ladder should be removed.
Ice stress on the ladder has broken it and may stress the tank shell and cause leaks.
Tank should be re-inspected in 2024.
Appendix I: Photographs
01 Overview of the tank
02 Overview of the tank
03 Shell ladder with safety cage
04 Overflow pipe with fine mesh screen
05 Lower shell manhole
06 Foundation and grade level
07 Lower shell and foundation with bio-growth in the trench
08 Tank anchors and chair systems
09 Visual level indicator
10 No bolt head caps
11 Anchor bolts are not tight
12 Opened roof access hatch
13 View of the tank roof
14 View of the roof, no nut caps installed
15 Central roof vent
16 Central roof vent screen with coarse and fine mesh screen intact
17 Roof railing system intact
18 Roof port for visual level indicator
19 Shell ladder to roof transition with small balcony
20 Interior roof and rafter system
21 Interior roof structures installed in the tank
22 Interior roof rafter to shell transition
1:34 - Interior roof structures and floating level indicator
1:46 - Interior overflow pipe
2:02 - Opened roof access hatch and interior ladder
2:25 - Central roof support system and central roof vent opening
2:53 - Roof plates and bolted seams
5:52 - Bent interior ladder brackets
7:06 - Raised inlet pipe
9:09 - Caulk repaired area on the interior shell
10:06 - Broken interior shell ladder and corrosion on brackets
11:00 - Lower shell manhole
12:33 - Sacrificial rod anode installed in the tank
13:11 - Corrosion on the bolts near the floor to shell seam
14:10 - Overflow pipe penetrating through the floor
14:14 - Inlet pipe, drain, and overflow pipe penetrating through the floor
14:57 - Outlet pipe with sediment ring installed
16:09 - Sediment at the center of the floor
Cleaning the sediment off the floor
Sediment cleaned off the floor
GLOSSARY OF TERMS FOR STEEL/CONCRETE TANKS
Adhesion- State in which two surfaces are held together by interfacial forces which may consist off valence forces or interlocking action or both
Aggregate- Granular material, such as sand, gravel, crushed stone, crushed hydraulic-cement concrete, or iron blast-furnace slag used with a hydraulic cementing medium to produce either concrete or mortar.
Bugholes- Small regular or irregular cavities, usually not exceeding 15 mm in diameter, resulting from entrapment of air bubbles in the surface of formed concrete during placement and compaction.
Cathodic Protection - The use of a sacrificial metal or energized substance to polarize the structures surfaces and prevents corrosion.
Chalking - The degradation of a paint binders when exposed to ultra-violet light which creates a loose residue on the surface.
Chemical Attack- Decomposition of a coating or concrete due to the action of a chemical.
Chime- Portion of tank floor plate that extends outside the tank shell and rests on top of the foundation.
Contraction Joint- Formed, sawed, or tooled groove in a concrete structure to create a weakened plane and regulate the location of cracking resulting
Corrosion Cell - A concentrated localized site of accelerated corrosion that creates pitting.
Disbondment- The loss of adhesion between a coating and the substrate.
Dry Film Thickness - Total thickness of a paint film when completely cured.
Efflorescence- A white crystalline or powdery deposit on the surface of concrete. Efflorescence results from leaching of lime or calcium hydroxide out of a permeable concrete mass over time by water, followed by reaction with carbon dioxide and acidic pollutants.
Finish- The texture of a concrete surface after compaction and finishing operations have been performed.
Finial Vent - The central roof vent on top of a water tank.
Grout- A plastic mixture of cementitious materials and water used as a filler for cracks, or other void spaces, in concrete surfaces to be coated.
Holiday - A hole or void in a protective coating that may be invisible to the unaided eye that extends to the substrate.
Honey Comb- Voids left in concrete due to failure of the mortar to effectively fill the spaces among coarse aggregate particles.
Hydraulic, Hydrostatic Pressure- A force exerted on the concrete/coating interface due to the level of the ground water.
Isolation Joint- A separation between adjoining parts of a concrete structure
Joint Sealant- Compressible material used to exclude water and solid foreign materials from joints.
Lap Joint Seam- Overlapping seam between roof plates that is open and un-welded on the interior.
Laitance- A thin, weak brittle layer of cement and aggregate fines on a concrete surface. The amount of laitance is influenced by the degree of working or the amount of water in the concrete.
Lead Abatement - The removal of a lead bearing paint system.
Lead Encapsulation - The covering over of a lead based paint by applying a compatible topcoat.
Osmotic Blister - Raised coating area created by build up of fluid under the coating. Fluid moves through coating in response to water/solvent concentrations between coating and tank water.
Osmotic Pressure- A force exerted on the concrete /coating interface through the capillaries in the concrete due to a moisture differential across the coating.
Overflow Weir Box- internal or external box that captures water above the operating height of the tank and directs it to an overflow pipe.
Pack Rust/Crevice Corrosion- Advanced form of steel corrosion that forms visible layers of oxidized steel swollen larger than the original steel plate thickness, usually found between steel plates or surfaces.
Pinholes- Film defect characterized by small pore-like flaws in a coating which extend entirely through the applied film and have the general appearance of pinpricks, fine holes, or voids when viewed by reflected light.
Plastic Cracking or Shrinkage- Cracking that occurs in the surface of fresh concrete soon after it is placed and while it is still plastic, Porosity- The ratio usually expressed as a percentage, of the volume of voids in a material to the total volume of the material, including the voids.
Reflective Cracking-Cracking that develops in a coating directly over a dynamic crack in concrete.
Rigging plug- Thread steel nipple welded to a tank roof for the purposes of rigging painting cables. Usually sealed with a threaded plug when no in use.
ROV - Remotely operated vehicle, underwater inspection device "TankRover" by CorrTech
Screen Mesh- Number of openings per linear inch of screen.
Silt - Material that accumulates in the bottom of a water tank originating from treatment by products, raw water particles and distribution system debris.
Silt Stop- Solid cylinder installed on a floor inlet or outlet pipe to extend the pipe above the floor. Pipe prevents floor sediment from being stirred up or sucked out of the tank during flow.
Static Cracks- A crack in the concrete surface whose width does not change.
GLOSSARY OF TERMS FOR STEEL/CONCRETE TANKS
Stich or Skip Weld- Method of welding two pieces of steel together with intermittent short sections of weld bead.
Leaves open lap joints along the unwelded sections.
Tubercle - Domed shaped buildup of corrosion products over an active corrosion site. Promotes metal loss through pitting due to differential oxygen concentrations.
Ultrasonic Measurement - The use of high frequency sound waves passed through a material to measure the time required to return. The time required to pass through the material is correlated to the speed of sound in the substrate to yield an actual thickness at a specific location.
Vapor Barrier- Waterproof membrane placed under concrete floor slabs that are placed on grade.
File details come from the government source that posted it. Updated .