ATT_6_Asbestos_Test_Report_PORE_Rohmann_140P8424Q0053_0001.pdf

PDF 2 MB Posted

Attached to
Rehabilitate Rohmann Residence, Point Reyes NS
Solicitation number
140P8424Q0053
Issued by

About this file

This document is an Asbestos Test Report for a federal contract opportunity. The report details the results of an asbestos inspection conducted at the Rohmann Residence located at 80 Silver Hills Rd, Point Reyes Station, CA 94956. The inspection found asbestos in the kitchen ceiling texture, mechanical room floor sheet vinyl, exterior window glazing, and office wall sheet vinyl. The identified asbestos-containing building materials (ACBMs) will need to be properly handled during the rehabilitation work.

The related federal contract opportunity is for the Rehabilitation of the Rohmann Residence at Point Reyes National Seashore. The work includes replacing the roof, updating the electrical system, and treating the structure for wood-destroying insects. This is a total small business set-aside with an estimated project value between $100,000 and $250,000. Quotations are due by the date and time specified in the solicitation, and a site visit is scheduled for May 13, 2024.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLM¹ Suspect Asbestos Bulk Sample Results

From: Air Environmental LLC P.O. Box 294 Santa Rosa, Ca 95402

To: Attn: Jesse Macklin Point Reyes National Seashore 1 Bear Valley Road Point Reyes Station, CA 94956

Date: 3-8-24

Address: 80 Silver Hills Rd, Point Reyes Station, CA 94956

Date of testing: 3-7-24

Per your request, Air Environmental performed suspect asbestos bulk sampling at the above referenced location. The purpose of this sample collection was to ascertain the presence or absence of asbestos in the suspect, Presumed Asbestos-Containing Material (PACM) / Asbestos Containing Building Material (ACBM), that will be disturbed during work activities.

This sample collection does not include any other areas and/or materials other than the areas and materials listed in this report. (see attached chain of custody forms and sampling area plan for listed sample locations)

During the course of this asbestos inspection (26) bulk samples were collected with the subsequent analysis of (46) discrete samples. The samples collected were cataloged on site and then delivered, Via FedEx, to Environmental Testing Laboratories for analysis by Polarized Light Microscopy (PLM¹). The analysis of the samples showed asbestos present in sample numbers listed on page 2. (also see attached laboratory report)

Sample Analysis Sample # Location Description Asbestos %

B4 Layer 3 Kitchen Ceiling Texture 1.75% Chrysotile

B9 Layer 1 Mechanical Room Floor Sheet Vinyl 35% Chrysotile

B13 Layer 1 Exterior Window Glazing Trace Chrysotile

B18 Layer 1 Office Wall Sheet Vinyl 20% Chrysotile

The ACBMs identified and collected in this report does not identify any other suspect materials that may be present in the area hidden in walls, above ceilings or floors covered with multiple layers of flooring materials. In the event that any other suspect materials are discovered during the work activities, all work must stop until the suspect materials, ACBMs, are collected and analyzed.

Asbestos Information

The Code of Federal Regulations (CFR), 40 CFR 61, Subpart M, National Emissions Standards for Hazardous Air Pollutants (NESHAP) and Federal Occupational Safety and Health Administration (FED OSHA) classify asbestos-containing material (ACM) as any material or product that contains greater than 1% asbestos. Non-friable ACM is classified by NESHAP as either Category I or Category II material defined as follows:

Category I – asbestos-containing packings, gaskets, resilient floor coverings, and asphalt roofing products.

Category II – all remaining types of non-friable asbestos-containing material not included in Category I that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Regulated asbestos-containing material (RACM), a hazardous waste, is classified as any manufactured material that contains greater than 1% asbestos by dry weight and is:

Friable (can be crumbled, pulverized, or reduced to powder by hand pressure); or

Category I material that has become friable; or

Category I material that has been subjected to sanding grinding, cutting or abrading; or

Category II non-friable material that has a high probability of becoming crumbled, pulverized, or reduced to a powder during demolition or renovation activities.

A homogeneous area shall be determined to contain asbestos based on a finding that the results of at least one sample collected from that area shows that asbestos is present. “Asbestos-containing construction material” (ACCM) means any manufactured construction material which contains more than one tenth of 1 percent asbestos by weight.

More than 50 countries, including the United Kingdom, Australia and all 28 countries of the European Union have banned the use of asbestos. However the U.S. continues to import and use asbestos with no plan for stricter regulations in place. We now know for certain that all forms of asbestos can cause mesothelioma, lung cancer and other chronic respiratory conditions. Although it is highly regulated in the U.S. asbestos continues to be used in hundreds of consumer products as long as it accounts for less than one percent <1% of the product by dry weight.

Activities that disturb materials containing asbestos are subject to certain requirements of the Cal/OSHA asbestos standard contained in Title 8, CCR Section 1529. Typically, removal or disturbance of more than 100 square feet of material containing more than 0.1% asbestos must be performed by a DOSH registered asbestos abatement contractor. Materials containing more than 1% asbestos are also subject to NESHAP regulations (40 CFR Part 61, Subpart M). RACM (friable ACM and non-friable ACM that will become friable during demolition operations) must be removed from structures prior to demolition.

Certain non-friable ACM and materials containing 1% or less asbestos may remain in structures during demolition; however, there are waste handling/disposal issues and Cal/OSHA work requirements that may make it cost ineffective to do so. Contractors are responsible for segregating and characterizing waste streams prior to disposal. With respect to potential worker exposure, notification, and registration requirements, Cal/OSHA defines asbestos-containing construction material as material that contains more than 0.1% asbestos (Title 8, CCR 341.6).

The Department of Toxic Substances Control (DTSC) classifies asbestos-containing material as a hazardous waste if it is “friable” and contains one percent (1.0%) or more asbestos as hazardous waste. A friable waste is one that can be reduced to a powder or dust under hand pressure when dry. This classification standard is given in California Code of Regulations, section 66261.24. Because the United States Environmental Protection Agency (U.S.EPA) does not regulate asbestos as hazardous waste under the Resource Conservation and Recovery Act (RCRA), it is considered to be a “non-RCRA, or “California-only” hazardous waste.

Joshua Leard, Nate Cowan & Pierce Tibbals Certified Asbestos Consultant

CA DOSH #21-6967

Office: 707-408-2080 Cell: 707-322-3183 CaEnvironmental@Gmail.com

¹ (PLM) Polarized Light Microscopy EPA Method 600/R-93-116 ² (NESHAP) National Emission Standards for Hazardous Air Pollutants

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Air Environmental

PO Box 294

Santa Rosa, California 95402

Project Location: 80 Silver Hills Rd., Point Reyes Station, CA 94956

Client Project: N/A

267310ETL Job:

Josh Leard

Lab Sample Number Client Sample Number Sample Type Completed

1643259 AsbestosB1 03/08/2024

1643260 AsbestosB2 03/08/2024

1643261 AsbestosB3 03/08/2024

1643262 AsbestosB4 03/08/2024

1643263 AsbestosB5 03/08/2024

1643264 AsbestosB6 03/08/2024

1643265 AsbestosB7 03/08/2024

1643266 AsbestosB8 03/08/2024

1643267 AsbestosB9 03/08/2024

1643268 AsbestosB10 03/08/2024

1643269 AsbestosB11 03/08/2024

1643270 AsbestosB12 03/08/2024

1643271 AsbestosB13 03/08/2024

1643272 AsbestosB14 03/08/2024

1643273 AsbestosB15 03/08/2024

1643274 AsbestosB16 03/08/2024

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type Completed

1643275 AsbestosB17 03/08/2024

1643276 AsbestosB18 03/08/2024

1643277 AsbestosB19 03/08/2024

1643278 AsbestosB20 03/08/2024

1643279 AsbestosB21 03/08/2024

1643280 AsbestosB22 03/08/2024

1643281 AsbestosB23 03/08/2024

1643282 AsbestosB24 03/08/2024

1643283 AsbestosB25 03/08/2024

1643284 AsbestosB26 03/08/2024

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 27 15

Point Count 1

Jessica Dilworth

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643259

B1 PLM 98% OtherPLM 2% CelluloseGrayDrywall

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643259

B1 PLM 99% OtherPLM 1% CelluloseWhiteTexture

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643260

B2 PLM 98% OtherPLM 2% CelluloseGrayDrywall

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643260

B2 PLM 98% OtherPLM 2% CelluloseWhiteTexture

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643261

B3 PLM 98% OtherPLM 2% CelluloseGrayDrywall

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643261

B3 PLM 99% OtherPLM 1% CelluloseWhiteTexture

Non-Fibrous

HomogenousLiving Room Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643262

B4 PLM 95% OtherPLM 5% CelluloseBrownDrywall

Non-Fibrous

HomogenousKitchen Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643262

B4 PLM 1% OtherPLM 99% CelluloseBrownPaper

Fibrous

HomogenousKitchen Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM 4% Chrysotile

PC 1.75% Chrysotile

1643262

B4 PLM 94% Other

PC 96.75% Other

PLM 2% Cellulose

PC 1.5% Cellulose

WhiteTexture

Non-Fibrous

HomogenousKitchen Ceiling

Layer-3 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643263

B5 PLM 97% OtherPLM 3% CelluloseBrownDrywall

Non-Fibrous

HomogenousKitchen Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643263

B5 PLM 1% OtherPLM 99% CelluloseBrownPaper

Fibrous

HomogenousKitchen Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

1643263

B5

Positive Stop

Kitchen Ceiling

Layer-3 Analyst: James Farinas

Date Analyzed : 03/08/2024

Layer Not Analyzed

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643264

B6 PLM 97% OtherPLM 3% CelluloseBrownDrywall

Non-Fibrous

HomogenousKitchen Ceiling

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643264

B6 PLM 1% OtherPLM 99% CelluloseBeigePaper

Fibrous

HomogenousKitchen Ceiling

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

1643264

B6

Positive Stop

Kitchen Ceiling

Layer-3 Analyst: James Farinas

Date Analyzed : 03/08/2024

Layer Not Analyzed

PLM None Detected 1643265

B7 PLM 20% OtherPLM 80% CelluloseWhite / GraySheet Vinyl with Fiber Backing

Fibrous

Non-HomogenousKitchen Floor

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643265

B7 PLM 90% OtherPLM 10% CelluloseTanMastic

Non-Fibrous

HomogenousKitchen Floor

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643266

B8 PLM 20% OtherPLM 80% CelluloseWhite / GraySheet Vinyl with Fiber Backing

Fibrous

Non-HomogenousKitchen Floor

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643266

B8 PLM 95% OtherPLM 5% CelluloseTanMastic

Non-Fibrous

HomogenousKitchen Floor

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM 35% Chrysotile1643267

B9 PLM 15% OtherPLM 50% CelluloseWhite / GraySheet Vinyl with Fiber Backing

Fibrous

Non-HomogenousMechanical Room Floor

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643267

B9 PLM 50% OtherPLM 50% CelluloseBlackMastic

Fibrous

HomogenousMechanical Room Floor

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

1643268

B10

Positive Stop

Mechanical Room Wall

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

Layer Not Analyzed

PLM None Detected 1643268

B10 PLM 55% OtherPLM 45% CelluloseBlackMastic

Fibrous

HomogenousMechanical Room Wall

Layer-2 Analyst: James Farinas

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643269

B11 PLM 95% OtherPLM 5% CelluloseBeigePanel Mastic

Non-Fibrous

HomogenousKitchen Wall Panel

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM None Detected 1643270

B12 PLM 98% OtherPLM 2% CelluloseBeigePanel Mastic

Non-Fibrous

HomogenousKitchen Wall Panel

Layer-1 Analyst: James Farinas

Date Analyzed : 03/08/2024

PLM Trace Chrysotile1643271

B13 PLM 100% OtherBlue / GreyWindow Glazing

Non-Fibrous

HomogenousKitchen Exterior

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM Trace Chrysotile1643272

B14 PLM 100% OtherBlue / GreyWindow Glazing

Non-Fibrous

HomogenousDining Room Exterior

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643273

B15 PLM 93% OtherPLM 7% CelluloseGrayDrywall

Non-Fibrous

HomogenousBedroom Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643273

B15 PLM 98% OtherPLM 2% CelluloseWhiteTexture

Non-Fibrous

HomogenousBedroom Wall

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643274

B16 PLM 90% OtherPLM 10% CelluloseGrayDrywall

Non-Fibrous

HomogenousBedroom Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643274

B16 PLM 98% OtherPLM 2% CelluloseWhiteTexture

Non-Fibrous

HomogenousBedroom Wall

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643275

B17 PLM 90% OtherPLM 10% CelluloseGrayDrywall

Non-Fibrous

HomogenousBedroom Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643275

B17 PLM 98% OtherPLM 2% CelluloseWhiteTexture

Non-Fibrous

HomogenousBedroom Wall

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM 20% Chrysotile1643276

B18 PLM 72% OtherPLM 8% CelluloseGold / GreySheet Vinyl

Non-Fibrous

HomogenousOffice Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643276

B18 PLM 96% OtherPLM 4% CelluloseTanMastic

Non-Fibrous

HomogenousOffice Wall

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

1643277

B19

Positive Stop

Bathroom Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

Layer Not Analyzed

PLM None Detected 1643277

B19 PLM 97% OtherPLM 3% CelluloseTanMastic

Non-Fibrous

HomogenousBathroom Wall

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643278

B20 PLM 96% OtherPLM 4% CelluloseBrown / GreyStucco

Non-Fibrous

Non-HomogenousExterior Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643279

B21 PLM 98% OtherPLM 2% CelluloseGrayStucco

Non-Fibrous

HomogenousExterior Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643280

B22 PLM 97% OtherPLM 3% CelluloseGrayStucco

Non-Fibrous

HomogenousExterior Wall

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643281

B23 PLM 90% OtherPLM 10% CelluloseGray / GreenConcrete

Non-Fibrous

HomogenousPlanter Box

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643282

B24 PLM 98% OtherPLM 2% CelluloseGray / GreenConcrete

Non-Fibrous

HomogenousPlanter Box

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643283

B25 PLM 85% OtherPLM 15% FiberglassBlackRoof Cap Sheet

Fibrous

HomogenousRoof Cap

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643283

B25 PLM 97% OtherPLM 3% CelluloseBlackAsphalt

Non-Fibrous

HomogenousRoof Cap

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Santa Rosa,California 95402

Air Environmental

PO Box 294

80 Silver Hills Rd., Point Reyes Station, CA 94956

ETL Job :

Client Project :

267310

N/A

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/07/2024

03/08/2024

Date Collected :

Date Received :

PLM None Detected 1643284

B26 PLM 77% OtherPLM 23% FiberglassBlackRoof Cap Sheet

Fibrous

HomogenousRoof Cap

Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

PLM None Detected 1643284

B26 PLM 96% OtherPLM 4% CelluloseBlackAsphalt

Non-Fibrous

HomogenousRoof Cap

Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/08/2024

Lab Supervisor/Other Signatory

James Farinas

OJ Ivey

Analyst:

400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")

Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples

Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples

EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials

EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples

A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Asbestos PLM - 80 Silver Hills Rd, Point Reyes Station, CA 94956
267310_Report
267310_COC
silver sketch

File details come from the government source that posted it. Updated .