This document is a construction design and specification package for the preservation and restoration of the historic Peaceful Valley Ranch House located in Theodore Roosevelt National Park in the South Unit near Medora, North Dakota (Billings County, zip code 80128).
The project scope involves comprehensive surface treatment and preservation of the ranch house's character-defining features. Key work requirements include: prepping and painting all previously painted exterior surfaces with removal of deteriorated or non-adhering paint while retaining sound historic paint layers; removing and replacing deteriorated sealant materials with new sealants compatible with environmental conditions; removing and replacing only existing window glazing putty that is visibly deteriorated while preserving intact glazing; removing all exterior existing daub in log walls and installing new daub per specifications; applying wood treatment to exterior surfaces of all wood logs; repairing split or damaged siding, trim, and windows to like-new condition prior to painting; removing exterior existing daub in log walls and installing new daub; providing bronze weatherstripping at jambs of existing operable windows and along all sides of existing operable doors; and ensuring factory-finished items are not painted. General staging and demolition notes specify that the ranch house will be closed to the public throughout construction with staging areas confined to established areas, all construction laydown shall remain within established areas without impeding vehicular traffic, and wild bison and horses may roam through the site requiring contractor precautions. The document includes detailed elevation photographs, construction staging plans, and architectural detail drawings showing specific treatment locations and methods for windows, doors, weatherstripping, and log wall restoration.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PEACEFUL VALLEY RANCH
Preserve Character Defining Features of Historic Peaceful Valley Ranch House
THEODORE ROOSEVELT NATIONAL PARK
PROJECT LOCATION MAP
NOT TO SCALE
80128
PARK LOCATION MAP
NOT TO SCALE
DESCRIPTION OF WORK
BACKGROUND: PEACEFUL VALLEY RANCH IS A HISTORIC, VISITOR-CENTERED CULTURAL LANDSCAPE THAT PLAYS A KEY ROLE IN EDUCATIONAL OUTREACH, PARTICULARLY FOR YOUTH, THROUGH PROGRAMS FOCUSED ON WILDLIFE AND NATURAL RESOURCE STEWARDSHIP. THE RANCH HOUSE IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES AND IS THE ONLY ORIGINAL RANCH HOUSE REMAINING IN THE SOUTH UNIT OF THEODORE ROOSEVELT NATIONAL PARK. THE RANCH HOUSE UNDERWENT SIGNIFICANT PRESERVATION WORK IN 2018, WHICH INCLUDED STABILIZATION OF THE BUILDING ENVELOPE, STRUCTURAL REPAIRS, COSMETIC REHABILITATION, AND MECHANICAL SYSTEM UPGRADES. AS PART OF THAT PROJECT, ALL PAINTED SURFACES WERE PREPPED, PRIMED, AND REPAINTED. SINCE THAT TIME, THE EXTERIOR COATINGS HAVE BEGUN TO DETERIORATE. PAINT IS NOW FLAKING AND PEELING, EXPOSING RAW WOOD TO THE ELEMENTS. OLDER LAYERS OF PAINT ARE LIFTING AND SEPARATING FROM THE SUBSTRATE, CREATING PATHWAYS FOR MOISTURE INFILTRATION AND POTENTIAL WOOD ROT. THE 2018 PROJECT INCLUDED SIGNIFICANT SITE CLEANUP INCLUDING SOIL REPLACEMENT AROUND THE RANCH HOUSE TO REMOVE LEAD CONTAMINATION. FULL EXTERIOR LEAD ABATEMENT WAS NOT COMPLETED, SO THERE CONTINUES TO BE LEAD-BASED PAINT WITHIN THE HISTORIC
LAYERS OF PAINT
SCOPE: : A COMPREHENSIVE SURFACE TREATMENT FOR THE PRESERVATION, MAINTENANCE, AND REHABILITATION OF THE HISTORIC PEACEFUL VALLEY RANCH HOUSE, LOCATED WITHIN THEODORE ROOSEVELT NATIONAL PARK. THE FOCUS IS ON RESTORING DETERIORATED EXTERIOR COATINGS AND MATERIALS TO GOOD CONDITION WHILE PRESERVING THE STRUCTURE'S HISTORIC CHARACTER. EXTERIOR SURFACES WILL BE PREPPED, PRIMED, AND PAINTED TO MAINTAIN WEATHERPROOFING AND ENCAPSULATE LEAD HAZARDS. THE RANCH HOUSE CONTAINS HISTORIC PAINT LAYERS THAT INCLUDE LEAD-BASED MATERIALS. LOOSE AND FLAKING LEAD-BASED PAINT WILL BE REMEDIATED, AND INTACT LAYERS WILL BE ENCAPSULATED. MEASURES WILL BE TAKEN DURING CONSTRUCTION TO PREVENT CONTAMINATION OF THE SURROUNDING SOIL. THE PROJECT ALSO INCLUDES FULL EXTERIOR AND SELECTIVE INTERIOR MORTAR DAUBING REPLACEMENT AND REPAIR TO ADDRESS DETERIORATION IN THE LOG CONSTRUCTION. THESE TREATMENTS AIM TO RESTORE THE PROTECTIVE INTEGRITY OF THE BUILDING ENVELOPE WHILE MAINTAINING ITS HISTORIC APPEARANCE. ADDITIONALLY, BRONZE WEATHER STRIPPING WILL BE INSTALLED ON ALL EXISTING OPERABLE WINDOWS AND DOORS.
REPAIRS AND TREATMENTS SHALL ALSO FOLLOW THE GUIDANCE PROVIDED IN THE 2014 PEACEFUL VALLEY RANCH HISTORIC STRUCTURES REPORT AND THE 2019 PEACEFUL VALLEY RANCH CULTURAL LANDSCAPE REPORT. ALL WORK MUST COMPLY WITH THE SECRETARY OF THE INTERIOR’S STANDARDS FOR THE TREATMENT OF HISTORIC PROPERTIES, SPECIFICALLY THE STANDARDS FOR REHABILITATION. THESE STANDARDS ARE
AVAILABLE AT:
https://www.nps.gov/tps/standards/rehabilitation.htm.
REGION MAP
NOT TO SCALE
AutoCAD SHX Text
DRAWING SHEET INDEX
AutoCAD SHX Text SHEET SUB SHEET TITLE OF SHEET SUB SHEET TITLE OF SHEET TITLE OF SHEET GENERAL 1 G0.0 COVER SHEET AND INDEX G0.0 COVER SHEET AND INDEX COVER SHEET AND INDEX 2 G0.1 CONSTRUCTION STAGING G0.1 CONSTRUCTION STAGING CONSTRUCTION STAGING ARCHITECTURAL 3 A2.1 PHOTO ELEVATIONS A2.1 PHOTO ELEVATIONS PHOTO ELEVATIONS 4 A5.1 ARCHITECTURAL DETAILS A5.1 ARCHITECTURAL DETAILS ARCHITECTURAL DETAILS
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M:\Groups\Maint\Active\THRO_337777_Peaceful Valley Ranch\50_CAD\THRO 337777_G0.0 COVER.dwg 12/16/2025 11:40 AM BY Tannehill, Daryl Lyn 12/16/2025 11:40 AM BY Tannehill, Daryl Lyn12/16/2025 11:40 AM BY Tannehill, Daryl Lyn BY Tannehill, Daryl LynTannehill, Daryl Lyn
AutoCAD SHX Text Date
AutoCAD SHX Text Mark
AutoCAD SHX Text Sheet
AutoCAD SHX Text
REVISION
AutoCAD SHX Text Initial
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text 337777A
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text Peaceful Valley Ranch Theodore Roosevelt National Park
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text G0.0
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
GENERAL INFORMATION
AutoCAD SHX Text
SHEET INDEX
AutoCAD SHX Text
AutoCAD SHX Text
MICHIGAN
AutoCAD SHX Text
INDIANAPOLIS
AutoCAD SHX Text
INDIANA
AutoCAD SHX Text
LITTLE ROCK
AutoCAD SHX Text
ARKANSAS
AutoCAD SHX Text
NEBRASKA
AutoCAD SHX Text
DES MOINES
AutoCAD SHX Text
KANSAS CITY
AutoCAD SHX Text
KANSAS
AutoCAD SHX Text
OMAHA
AutoCAD SHX Text
ST. LOUIS
AutoCAD SHX Text
MISSOURI
AutoCAD SHX Text
ILLINOIS
AutoCAD SHX Text
MINNEAPOLIS
AutoCAD SHX Text
PIERRE
AutoCAD SHX Text
SOUTH DAKOTA
AutoCAD SHX Text
MADISON
AutoCAD SHX Text
IOWA
AutoCAD SHX Text
CHICAGO
AutoCAD SHX Text
WISCONSIN
AutoCAD SHX Text
NORTH DAKOTA
AutoCAD SHX Text
MINNESOTA
AutoCAD SHX Text
FARGO
AutoCAD SHX Text
COLUMBUS
AutoCAD SHX Text
OHIO
AutoCAD SHX Text
DETROIT
AutoCAD SHX Text
PROJECT LOCATION: THRO SOUTH UNIT, NORTH DAKOTA
AutoCAD SHX Text 12/12/2025
AutoCAD SHX Text
80128
CONSTRUCTION STAGING PLAN
NOT TO SCALE
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M:\Groups\Maint\Active\THRO_337777_Peaceful Valley Ranch\50_CAD\THRO 337777_G0.1 STAGING.dwg 12/16/2025 11:41 AM BY Tannehill, Daryl Lyn 12/16/2025 11:41 AM BY Tannehill, Daryl Lyn12/16/2025 11:41 AM BY Tannehill, Daryl Lyn BY Tannehill, Daryl LynTannehill, Daryl Lyn
AutoCAD SHX Text Date
AutoCAD SHX Text Mark
AutoCAD SHX Text Sheet
AutoCAD SHX Text
REVISION
AutoCAD SHX Text Initial
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text 337777A
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text Peaceful Valley Ranch Theodore Roosevelt National Park
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text G0.1
AutoCAD SHX Text
CONSTRUCTION STAGING
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL STAGING NOTES
AutoCAD SHX Text
1. RANCH HOUSE WILL BE CLOSED TO THE PUBLIC THROUGHOUT CONSTRUCTION BUT OTHER AREAS OF SITE WILL BE OPEN TO PARK AND VISITOR USE AS NOTED. 2. ALL CONSTRUCTION LAYDOWN SHALL BE WITHIN ALL CONSTRUCTION LAYDOWN SHALL BE WITHIN ESTABLISHED AREAS AND SHALL NOT IMPEDE VEHICULAR SITE ACCESS. 3. WILD BISON AND HORSES ROAM THROUGH THE SITE AT WILD BISON AND HORSES ROAM THROUGH THE SITE AT ANY TIME OF THE YEAR. DO NOT APPROACH THEM. 4. CONSTRUCTION FENCING SHALL BE SUPPORTED BY CONSTRUCTION FENCING SHALL BE SUPPORTED BY CONCRETE BASES. NO GROUND PENETRATING STAKING IS ALLOWED. 5. PARK WILL BE RESPONSIBLE FOR SNOW REMOVAL TO THE PARK WILL BE RESPONSIBLE FOR SNOW REMOVAL TO THE SITE AND DRIVE LANE THRU SITE. ALL OTHER DETAILED SNOW REMOVAL AROUND WORK AREAS SHALL BE CONTRACTOR'S RESPONSIBILITY. 6. NON-POTABLE WATER WILL NOT BE AVAILABLE TO THE NON-POTABLE WATER WILL NOT BE AVAILABLE TO THE CONTRACTOR OCTOBER-APRIL
AutoCAD SHX Text A. SCOPE OF WORK: RANCH HOUSE SCOPE OF WORK: RANCH HOUSE B. PROVIDE UNOBSTRUCTED ACCESS. PARK VISITORS AND PROVIDE UNOBSTRUCTED ACCESS. PARK VISITORS AND STAFF SHALL BE ALLOWED TRAILHEAD PARKING AND ACCESS IN THIS AREA THROUGHOUT THE CONSTRUCTION DURATION. C. THIS AREA IS DESIGNATED FOR CONTRACTOR USE, THIS AREA IS DESIGNATED FOR CONTRACTOR USE, INCLUDING LAYDOWN SPACE, JOB TRAILER, STORAGE, TEMPORARY FENCING, PORTA-JOHNS FOR THE CONSTRUCTION CREW, AND A DUMPSTER. CONTRACTOR SHALL ENSURE THAT ALL ITEMS PLACED IN THIS AREA REMAIN ON NON-VEGETATED AREAS. D. CONTRACTOR TO PROVIDE ROAD ACCESS FOR PUBLIC AND CONTRACTOR TO PROVIDE ROAD ACCESS FOR PUBLIC AND NPS THROUGHOUT CONSTRUCTION. NPS WILL USE A MINIMUM 2X DAILY FROM MAY TO NOVEMBER AND PUBLIC USE WILL BE SPORADIC. E. EXISTING VAULT TOILET IS FOR NPS AND VISITOR USE EXISTING VAULT TOILET IS FOR NPS AND VISITOR USE ONLY. CONTRACTOR SHALL PROVIDE UNOBSTRUCTED ACCESS FOR NPS USE AND SERVICING THROUGHOUT CONSTRUCTION. F. LOCATION OF NON-POTABLE WATER LOCATION OF NON-POTABLE WATER G. APPROXIMATE LOCATION OF EXISTING SEPTIC LEACH FIELD APPROXIMATE LOCATION OF EXISTING SEPTIC LEACH FIELD SYSTEM.
AutoCAD SHX Text
STAGING KEY NOTES
AutoCAD SHX Text
1. REFER TO DIVISION 1 PROJECT SPECIFICATIONS AND ALL REFER TO DIVISION 1 PROJECT SPECIFICATIONS AND ALL SPECIFICATIONS RELATED TO THE PROPOSED SCOPE OF WORK OUTLINED IN THESE CONSTRUCTION DOCUMENTS 2. IN THE EVENT OF DISCREPANCIES WITHIN THE DRAWINGS IN THE EVENT OF DISCREPANCIES WITHIN THE DRAWINGS OR SPECIFICATIONS, THE GREATER QUALITY AND QUANTITY OF THE ITEMS IN QUESTION SHALL BE UTILIZED AT ALL LOCATIONS WHERE SUCH DISCREPANCIES OCCUR. 3. CONTRACTOR SHALL FIELD-VERIFY ALL CONDITIONS AND CONTRACTOR SHALL FIELD-VERIFY ALL CONDITIONS AND DIMENSIONS BEFORE BIDDING AND CONSTRUCTION. DO NOT SCALE DRAWINGS. DIMENSIONS ARE TO FACE OF FINISHED WALL UNLESS NOTED. 4. VISIT THE SITE BEFORE BIDDING. NO ADDITIONAL SCOPE VISIT THE SITE BEFORE BIDDING. NO ADDITIONAL SCOPE WILL BE APPROVED FOR OBSERVABLE CONDITIONS. 5. PURSUANT TO THE FEDERAL OSHA EMPLOYEE PURSUANT TO THE FEDERAL OSHA EMPLOYEE RIGHT-TO-KNOW ACT, THE CONTRACTOR IS HEREBY ADVISED THAT A LEAD HAZARD EXISTS. LEAD PAINT MAY BE PRESENT ON OLDER PAINTED SURFACES. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH THE FEDERAL STANDARDS FOR LEAD PAINT IN THE CONSTRUCTION INDUSTRY, AS ADOPTED BY OSHA IN JUNE 1993 (CFR 29 PART 1926.62). THESE REGULATIONS REQUIRE THE CONTRACTOR TO DEVELOP SAFE WORK STRATEGIES FOR WORKING WITH LEAD IN ORDER TO MINIMIZE EXPOSURE AND PROTECT WORKERS FROM LEAD HAZARDS. ALL MATERIALS MUST BE DISPOSED OF PROPERLY, AS REQUIRED BY LAW. 6. THE CONTRACTOR IS RESPONSIBLE FOR ALL THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEANS AND METHODS, LABOR, MATERIALS, COORDINATION, SCHEDULING, MATERIAL VERIFICATION, AND PROCUREMENT, IN FULL COMPLIANCE WITH THE CONTRACT DOCUMENTS. BEFORE BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL THOROUGHLY REVIEW ALL DRAWINGS AND SPECIFICATIONS, VERIFY EXISTING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM THAT THE WORK CAN BE EXECUTED AS SHOWN. THE CONTRACTOR MUST BE FULLY FAMILIAR WITH THE PROJECT SCOPE, SCHEDULE, AND DEADLINES, AND IS SOLELY RESPONSIBLE FOR MANAGING THE CONSTRUCTION PROCESS, INCLUDING MATERIAL ORDERING AND SCHEDULE ADHERENCE. UPON RECEIPT OF THE NOTICE TO PROCEED, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE CONTRACTING OFFICER (CO) OF ANY LONG-LEAD ITEMS THAT MAY AFFECT THE PROJECT TIMELINE. WHEN REQUESTED, THE CONTRACTOR SHALL PROVIDE ORDER CONFIRMATIONS AND DELIVERY DATES 7. IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS AFFECTED BY CONSTRUCTION RESULT IN A FINISHED AND COMPLETE PROJECT. THE CONTRACTOR SHALL PATCH, REPAIR, AND ADJUST EXISTING CONSTRUCTION AS REQUIRED--DUE TO DEMOLITION OR NEW WORK--TO ACHIEVE THIS OUTCOME. ALL REPAIRS OR REPLACEMENTS MUST BE MADE IN KIND, MATCHING THE EXISTING MATERIALS IN PROPERTIES, TEXTURE, PROFILE, DIMENSION, FINISH, AND, WHERE APPLICABLE, SPECIES. FOR AREAS NOT SPECIFICALLY DETAILED, THE QUALITY AND DESIGN SHALL ALIGN WITH THE INTENT SHOWN IN OTHER AREAS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) PRIOR TO PROCEEDING WITH ANY AREAS REQUIRING CLARIFICATION OR DIRECTION. 8. THE CONTRACTOR SHALL CONSTRUCT IN CONFORMANCE THE CONTRACTOR SHALL CONSTRUCT IN CONFORMANCE WITH ALL GOVERNING STATE AND LOCAL CODES, ORDINANCES, AND PROCEDURES. 9. CONTRACTOR AND SUBCONTRACTORS MUST BE LICENSED CONTRACTOR AND SUBCONTRACTORS MUST BE LICENSED AND INSURED PER FEDERAL REQUIREMENTS. 10. THE CONTRACTOR IS RESPONSIBLE FOR THE THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL SHOP DRAWINGS AND SUBMITTALS WITH ALL TRADES. 11. PROVIDE ALL NECESSARY ACCESS, EQUIPMENT, PROVIDE ALL NECESSARY ACCESS, EQUIPMENT, SHORING, AND BRACING. EXTERIOR WORK SHOULD BE ACCESSED FROM OUTSIDE; LIMITED INTERIOR ACCESS MUST BE COORDINATED WITH THE COR. 12. NOTIFY THE COR OF ANY CONFLICTS, QUESTIONS, OR NOTIFY THE COR OF ANY CONFLICTS, QUESTIONS, OR UNFORESEEN CONDITIONS. CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE COR PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. 13. COORDINATE PHASING, ACCESS, AND UTILITY COORDINATE PHASING, ACCESS, AND UTILITY INTERRUPTIONS WITH THE COR. WORK THAT REQUIRES THE USE OF LOUD EQUIPMENT THAT MAY DISTURB BUILDING OCCUPANTS OR INTERFERE WITH TOURS MUST BE APPROVED BY THE COR. 14. CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF PERSONS AND PROPERTY. THE CONTRACTOR IS RESPONSIBLE FOR SECURING THE CONSTRUCTION AREA AND SHALL BE LIABLE FOR ANY DAMAGE OR THEFT RESULTING FROM NEGLECT OR UNAUTHORIZED ACCESS. COORDINATE SECURITY MEASURES WITH THE COR AND PARK STAFF. 15. PROTECT ALL SITE LOCATIONS AND EXISTING PROTECT ALL SITE LOCATIONS AND EXISTING CONDITIONS NOT DESIGNATED FOR REMOVAL. ANY DAMAGE CAUSED BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. THIS INCLUDES, BUT IS NOT LIMITED TO, CURBS, PAVING, TURF, EQUIPMENT, VEGETATION, ADJACENT WALLS, ROOFING, WINDOWS, ETC., AS REQUIRED TO MATCH EXISTING CONDITIONS. 16. THE LOCATIONS OF UNDERGROUND UTILITIES ARE THE LOCATIONS OF UNDERGROUND UTILITIES ARE UNKNOWN. NO EXCAVATION IS PERMITTED. THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES AND MECHANICAL, LIGHTNING PROTECTION AND ELECTRICAL SYSTEMS ACCORDINGLY. 17. PROTECT ROOFS AND BUILDING SURFACES. DO NOT PROTECT ROOFS AND BUILDING SURFACES. DO NOT ALLOW ANY CHEMICAL STRIPPERS OR CLEANING FLUIDS TO CONTACT ROOF SURFACES OR BUILDING WALLS. 18. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING WATER THE CONTRACTOR IS RESPONSIBLE FOR KEEPING WATER OUT OF THE BUILDING AND BUILDING SYSTEMS AT ALL TIMES. DO NOT ALLOW WATER FROM PAINT REMOVAL AND CLEANING OPERATIONS TO ENTER THE BUILDING. COLLECT ALL RUNOFF FROM PAINT REMOVAL AND DISPOSE OF IT PROPERLY IN ACCORDANCE WITH ENVIRONMENTAL LAWS AND HAZARDOUS ABATEMENT DRAWINGS. 19. SEAL ALL EXTERIOR PENETRATIONS WEATHER-TIGHT SEAL ALL EXTERIOR PENETRATIONS WEATHER-TIGHT AND INSULATE BEFORE PAINTING. PROVIDE SEALANT AT ALL VERTICAL AND HORIZONTAL JOINTS BETWEEN DISSIMILAR MATERIALS AT AREAS OF REPAIR. SEALANT COLOR SHALL MATCH ADJACENT SURFACES OR BE PAINTABLE. 20. CLEAN SURFACES AS REQUIRED FOR NEW PAINT CLEAN SURFACES AS REQUIRED FOR NEW PAINT SYSTEMS. 21. NO SUBSTITUTIONS OF SPECIFIED ITEMS WITHOUT NO SUBSTITUTIONS OF SPECIFIED ITEMS WITHOUT WRITTEN COR APPROVAL.
AutoCAD SHX Text
1. PRIOR TO DEMOLITION, THE CONTRACTOR SHALL PRIOR TO DEMOLITION, THE CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS OF ALL COMPONENTS WITHIN AND ADJACENT TO THE SCOPE OF WORK WITH PHOTOS, AND SUBMIT TO THE PROJECT TEAM FOR RECORD. 2. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING EXISTING CONDITIONS TO REMAIN AND SHALL REPAIR ANY DAMAGE CAUSED DURING DEMOLITION TO ORIGINAL CONDITION. 3. REMOVE ALL DEMOLITION DEBRIS FROM THE SITE AND REMOVE ALL DEMOLITION DEBRIS FROM THE SITE AND DISPOSE OF IT AT A LICENSED LANDFILL. PROVIDE WRITTEN PROOF TO THE COR. DUMPSTER PLACEMENT MUST BE APPROVED BY THE COR PER THE SPECIFICATIONS. 4. ITEMS NOT IDENTIFIED FOR REMOVAL SHALL REMAIN ITEMS NOT IDENTIFIED FOR REMOVAL SHALL REMAIN UNDISTURBED. CUT AND PATCH EXISTING AND NEW WORK AS REQUIRED. 5. MAINTAIN A SECURE, WEATHER-TIGHT BUILDING DAILY. MAINTAIN A SECURE, WEATHER-TIGHT BUILDING DAILY. THE CONTRACTOR IS LIABLE FOR DAMAGES RESULTING FROM NEGLIGENCE, AN UNSECURED SITE, OR IMPROPER WEATHER-TIGHT MEASURES.
AutoCAD SHX Text
GENERAL DEMOLITION NOTES
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text G0.1
AutoCAD SHX Text 12/12/2025
ELEVATION - WEST
ELEVATION - SOUTH
SCALE: NOT TO SCALE
ELEVATION - NORTH
ELEVATION - EAST
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
INTERIOR PORCH - LOOKING WEST
SCALE: NOT TO SCALE
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M:\Groups\Maint\Active\THRO_337777_Peaceful Valley Ranch\50_CAD\THRO 337777_A2.1_A5.1_Photo Elevations and Details.dwg 12/16/2025 11:53 AM BY Tannehill, Daryl Lyn 12/16/2025 11:53 AM BY Tannehill, Daryl Lyn12/16/2025 11:53 AM BY Tannehill, Daryl Lyn BY Tannehill, Daryl LynTannehill, Daryl Lyn
AutoCAD SHX Text Date
AutoCAD SHX Text Mark
AutoCAD SHX Text Sheet
AutoCAD SHX Text
REVISION
AutoCAD SHX Text Initial
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text 337777A
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text Peaceful Valley Ranch Theodore Roosevelt National Park
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text A2.1
AutoCAD SHX Text
PHOTO ELEVATIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLAG NOTE
AutoCAD SHX Text
FLAG NOTE DESIGNATION
AutoCAD SHX Text
AutoCAD SHX Text
REFERENCE LEGEND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION DETAIL CALL OUT
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text X
AutoCAD SHX Text X.X
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text A5.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text A5.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text 12/12/2025
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text PREP, PRIME, AND PAINT ALL PREVIOUSLY PAINTED EXTERIOR SURFACES PER SPECIFICATIONS. REMOVE ONLY DETERIORATED OR NON-ADHERING PAINT; RETAIN SOUND, EXISTING HISTORIC PAINT LAYERS. PREPARE SURFACES FOR PAINTING IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. LEAD-BASED PAINT IS PRESENT. IMPLEMENT ALL REQUIRED PROTECTION AND COLLECTION MEASURES TO COMPLY WITH APPLICABLE CODES. REMOVE AND REPLACE ALL EXISTING DETERIORATED SEALANT MATERIALS WITH NEW SEALANTS COMPATIBLE WITH ADJACENT SUBSTRATES AND ENVIRONMENTAL CONDITIONS. SEAL ALL OPEN JOINTS, UNLESS EXPLICITLY NOTED TO REMAIN UNSEALED. PROVIDE AND INSTALL ALL SEALANTS PER THE SPECIFICATIONS. REMOVE AND REPLACE ONLY EXISTING WINDOW GLAZING PUTTY THAT IS VISIBLY DETERIORATED, LOOSE, CRACKED, OR OTHERWISE COMPROMISED. GLAZING PUTTY THAT IS INTACT, WELL-ADHERED, AND IN SOUND CONDITION SHALL REMAIN IN PLACE AND BE PROTECTED DURING THE WORK. APPLY GLAZING PUTTY PER THE SPECIFICATIONS. REMOVE ALL EXTERIOR EXISTING DAUBING IN LOG WALLS. INSTALL NEW DAUBING PER THE SPECIFICATIONS. APPLY WOOD TREATMENT TO EXTERIOR SURFACE OF ALL WOOD LOGS PER THE SPECIFICATIONS. REPAIR SPLIT OR DAMAGED SIDING, TRIM, OR WINDOWS TO LIKE-NEW CONDITION PRIOR TO PAINTING, IN ACCORDANCE WITH THE SPECIFICATIONS. REPLACE ANY WOOD THAT IS DETERIORATED BEYOND REPAIR OR OTHERWISE COMPROMISED, AS NECESSARY, TO MAINTAIN MATERIAL INTEGRITY AND ENSURE PROPER PERFORMANCE PRIOR TO PAINTING. EXISTING NON-OPERABLE WINDOWS SHALL REMAIN SEALED AND INOPERABLE. ENSURE ALL WINDOWS ARE PROPERLY SEALED AND WEATHERTIGHT. EXISTING SEALANT SHALL BE PAINTED TO MATCH THE WINDOW FRAME COLOR. PROVIDE BRONZE WEATHERSTRIPPING AT THE JAMBS OF EXISTING OPERABLE WINDOWS. REFER TO DETAIL 7/A5.1 ENSURE ALL WINDOWS THAT WERE OPERABLE PRIOR TO PAINTING REMAIN OPERABLE AND HAVE NOT BEEN INADVERTENTLY SEALED OR PAINTED SHUT DURING THE COURSE OF THE WORK. PROVIDE BRONZE WEATHERSTRIPPING ALONG ALL SIDES OF EXISTING OPERABLE DOORS, INCLUDING THE JAMBS AND HEAD. REFER TO DETAIL 8/A5.1. FACTORY-FINISHED ITEMS; DO NOT PAINT. ON BOTH SIDES OF THE DOOR FRAME, REMOVE THE LOOSE AND SEPARATED DAUBING BETWEEN THE WOOD LOG WALL AND THE BACK OF THE DOOR FRAME. REPLACE WITH SCRIBED WOOD TRIM, FITTED SNUGLY AGAINST THE LOG WALL. REFER TO DETAIL 6/A5.1.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WEST ELEVATION - DETAIL VIEW
SCALE: NOT TO SCALE
WEST ELEVATION - DETAIL VIEW
SCALE: NOT TO SCALE
NORTH ELEVATION - DETAIL VIEW
SCALE: NOT TO SCALE
NORTH ELEVATION - DOOR FRAME VIEW
SCALE: NOT TO SCALE
NORTH ELEVATION - DOOR FRAME DETAIL
SCALE: 1" = 1'-0"
OPERABLE WINDOW - DETAIL VIEW OF BRONZE WEATHERSTRIP
SCALE: 1" = 1"
OPERABLE DOOR - DETAIL VIEW OF BRONZE WEATHERSTRIP
SCALE: 1" = 1"
WEST ELEVATION - DETAIL VIEW
SCALE: NOT TO SCALE
AutoCAD SHX Text
FACE OF DOOR FRAME
AutoCAD SHX Text ON BOTH SIDES OF THE DOOR FRAME, AFTER NEW EXTERIOR DAUBING IS IN PLACE, SCRIBE WOOD TRIM TO FIT SNUGLY AGAINST THE LOG WALL, ENSURING THE GAP BETWEEN THE BACK OF THE DOOR FRAME AND THE LOG WALL IS FULLY CLOSED. PAINT TRIM TO MATCH THE DOOR FRAME.
AutoCAD SHX Text
WOOD LOG WALL
AutoCAD SHX Text ADD SEALANT TO EDGES OF WOOD TRIM TO ENSURE A WEATHER-TIGHT AND FINISHED APPEARANCE.
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text INSTALL NEW BRONZE CUSHION / SPRING WEATHERSTRIP (1-1/8") BASIS OF DESIGN PRODUCT: PEMKO_70C OR APPROVED EQUAL. PRIOR TO ORDERING, FIELD-VERIFY DIMENSIONS OF EXISTING WINDOWS AND FRAMES TO ENSURE PROPER COORDINATION AND COMPATIBILITY OF WEATHERSTRIPPING SIZE
AutoCAD SHX Text
EXISTING OPERABLE WINDOW
AutoCAD SHX Text FASTEN WEATHERSTRIPPING TO FRAME, CENTERED ON EXISTING WINDOW SASH, TYPICAL. SECURE WITH SOLID BRONZE NAILS SPACED NO MORE THAN 3 INCHES ON CENTER, OR AS REQUIRED BY THE MANUFACTURER.
AutoCAD SHX Text NOTES: DOUBLE-HUNG OR SINGLE-HUNG WINDOWS: PROVIDE WEATHERSTRIPPING AT THE JAMBS ONLY. JAMB WEATHERSTRIPPING SHALL EXTEND A MINIMUM OF 1 INCH BEYONG THE OPERABLE SASH WHEN THE WINDOW IS CLOSED. ORIENT THE SPRING SIDE OF THE WEATHERSTRIPPING IN THE DIRECTION TOWARD THE EXTERIOR, AND THE FLAT SIDE TOWARD THE INTERIOR. CASEMENT, AWNING, OR SIMILAR WINDOWS: INSTALL WEATHERSTRIPPING ON THE WINDOW FRAME, ALONG SIDES AND TOP OF WINDOW. TERMINATE SEGMENTS AS REQUIRED TO AVOID INTERFERENCE WITH HINGES AND LATCH HARDWARE. ENSURE A SECURE FIT AND UNOBSTRUCTED OPERATION. ORIENT THE SPRING SIDE OF THE WEATHERSTRIP OPPOSITE THE DIRECTION OF WINDOW SWING.
AutoCAD SHX Text ENSURE THE SPRING SIDE OF THE WEATHERSTRIP IS ORIENTED IN THE OPPOSITE DIRECTION FROM THE DOOR SWING.
AutoCAD SHX Text
SWING DIRECTION
AutoCAD SHX Text
EXISTING DOOR
AutoCAD SHX Text
EXISTING DOOR JAMB
AutoCAD SHX Text INSTALL NEW 1-1/8" BRONZE CUSHION/SPRING-TYPE WEATHERSTRIP ON THE DOOR FRAME, ALONG SIDES AND TOP OF THE DOOR, CENTERED ON DOOR. TERMINATE WEATHERSTRIP SEGMENTS AS REQUIRED TO PREVENT INTERFERENCE WITH HINGES AND LATCH HARDWARE, ENSURING A SECURE FIT AND UNOBSTRUCTED DOOR OPERATION. BASIS OF DESIGN PRODUCT: PEMKO 70C, OR APPROVED EQUAL. PRIOR TO ORDERING, FIELD-VERIFY DIMENSIONS OF EXISTING DOORS, AND FRAMES TO ENSURE PROPER COORDINATION AND COMPATIBILITY OF WEATHERSTRIPPING SIZE.
AutoCAD SHX Text FASTEN WEATHERSTRIPPING TO FRAME, CENTERED ON EXISTING DOOR, TYPICAL. SECURE WITH SOLID BRONZE NAILS SPACED NO MORE THAN 3 INCHES ON CENTER, OR AS REQUIRED BY THE MANUFACTURER.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M:\Groups\Maint\Active\THRO_337777_Peaceful Valley Ranch\50_CAD\THRO 337777_A2.1_A5.1_Photo Elevations and Details.dwg 12/16/2025 11:53 AM BY Tannehill, Daryl Lyn 12/16/2025 11:53 AM BY Tannehill, Daryl Lyn12/16/2025 11:53 AM BY Tannehill, Daryl Lyn BY Tannehill, Daryl LynTannehill, Daryl Lyn
AutoCAD SHX Text Date
AutoCAD SHX Text Mark
AutoCAD SHX Text Sheet
AutoCAD SHX Text
REVISION
AutoCAD SHX Text Initial
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text 337777A
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text Peaceful Valley Ranch Theodore Roosevelt National Park
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text A5.1
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
FLAG NOTE
AutoCAD SHX Text
FLAG NOTE DESIGNATION
AutoCAD SHX Text
AutoCAD SHX Text
REFERENCE LEGEND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION DETAIL CALL OUT
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text X
AutoCAD SHX Text X.X
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text A5.1
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text 12/12/2025
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text PREP, PRIME, AND PAINT ALL PREVIOUSLY PAINTED EXTERIOR SURFACES PER SPECIFICATIONS. REMOVE ONLY DETERIORATED OR NON-ADHERING PAINT; RETAIN SOUND, EXISTING HISTORIC PAINT LAYERS. PREPARE SURFACES FOR PAINTING IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. LEAD-BASED PAINT IS PRESENT. IMPLEMENT ALL REQUIRED PROTECTION AND COLLECTION MEASURES TO COMPLY WITH APPLICABLE CODES. REMOVE AND REPLACE ALL EXISTING DETERIORATED SEALANT MATERIALS WITH NEW SEALANTS COMPATIBLE WITH ADJACENT SUBSTRATES AND ENVIRONMENTAL CONDITIONS. SEAL ALL OPEN JOINTS, UNLESS EXPLICITLY NOTED TO REMAIN UNSEALED. PROVIDE AND INSTALL ALL SEALANTS PER THE SPECIFICATIONS. REMOVE AND REPLACE ONLY EXISTING WINDOW GLAZING PUTTY THAT IS VISIBLY DETERIORATED, LOOSE, CRACKED, OR OTHERWISE COMPROMISED. GLAZING PUTTY THAT IS INTACT, WELL-ADHERED, AND IN SOUND CONDITION SHALL REMAIN IN PLACE AND BE PROTECTED DURING THE WORK. APPLY GLAZING PUTTY PER THE SPECIFICATIONS. REMOVE ALL EXTERIOR EXISTING DAUBING IN LOG WALLS. INSTALL NEW DAUBING PER THE SPECIFICATIONS. APPLY WOOD TREATMENT TO EXTERIOR SURFACE OF ALL WOOD LOGS PER THE SPECIFICATIONS. REPAIR SPLIT OR DAMAGED SIDING, TRIM, OR WINDOWS TO LIKE-NEW CONDITION PRIOR TO PAINTING, IN ACCORDANCE WITH THE SPECIFICATIONS. REPLACE ANY WOOD THAT IS DETERIORATED BEYOND REPAIR OR OTHERWISE COMPROMISED, AS NECESSARY, TO MAINTAIN MATERIAL INTEGRITY AND ENSURE PROPER PERFORMANCE PRIOR TO PAINTING. EXISTING NON-OPERABLE WINDOWS SHALL REMAIN SEALED AND INOPERABLE. ENSURE ALL WINDOWS ARE PROPERLY SEALED AND WEATHERTIGHT. EXISTING SEALANT SHALL BE PAINTED TO MATCH THE WINDOW FRAME COLOR. PROVIDE BRONZE WEATHERSTRIPPING AT THE JAMBS OF EXISTING OPERABLE WINDOWS. REFER TO DETAIL 7/A5.1 ENSURE ALL WINDOWS THAT WERE OPERABLE PRIOR TO PAINTING REMAIN OPERABLE AND HAVE NOT BEEN INADVERTENTLY SEALED OR PAINTED SHUT DURING THE COURSE OF THE WORK. PROVIDE BRONZE WEATHERSTRIPPING ALONG ALL SIDES OF EXISTING OPERABLE DOORS, INCLUDING THE JAMBS AND HEAD. REFER TO DETAIL 8/A5.1. FACTORY-FINISHED ITEMS; DO NOT PAINT. ON BOTH SIDES OF THE DOOR FRAME, REMOVE THE LOOSE AND SEPARATED DAUBING BETWEEN THE WOOD LOG WALL AND THE BACK OF THE DOOR FRAME. REPLACE WITH SCRIBED WOOD TRIM, FITTED SNUGLY AGAINST THE LOG WALL. REFER TO DETAIL 6/A5.1.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| COVER |
File details come from the government source that posted it. Updated .