Atch_1_to_Amd_1_QandAs_0001.pdf

PDF 83 KB Posted

Attached to
Routine Boat Maintenance (Mocama)-CUIS Federal contract opportunity
Solicitation number
140P5424Q0030
Issued by
Department of the Interior National Park Service Southeast Region

About this file

This document is a Questions and Answers (Q&A) attachment to Amendment 1 of Solicitation 140P5424Q0030 issued by the National Park Service Southeast Region for routine boat maintenance services. The solicitation is a total small business set-aside for NAICS code 336611, Ship Building and Repairing.

The Q&A provides responses to 16 questions from offerors about the required work, including details on the fire suppression system, propellers, engine room, lettering, hull anodes, impellers, transmissions, heat exchangers, and other vessel specifications. It also clarifies terms like "fleethe vessel" and addresses availability of a previous paint report, name change requirements, and approval of non-slip aggregate. The solicitation has an anticipated award date in late July 2024 for a firm-fixed-price purchase order with a performance period of up to 30 days.

View the file

Other files for this federal contract opportunity

Other files attached to Routine Boat Maintenance (Mocama)-CUIS, newest first.
File Type Posted
Sol_140P5424Q0030_Amd_0001.pdf PDF
Atch_2_Required_Form.pdf PDF
Sol_140P5424Q0030.pdf PDF
Atch_1_SOW.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

140P5424Q0030 Amendment 1 Attachment 1

Question #1: Is the fire system FM200?

Answer: Fire System: Model: H 120 WO: 184657 Tare Weight: 104 lbs.

Agent Weight: 102 lbs.

Gross Weight: 208 lbs.

CYL SERIAL NO. 162.161/4/0

Question #2: What is the size of the propellers?

Answer: 28x34

Question #3: What is the size of the engine room?

Answer: 13x20x7

Question #4: How big are the letters on the legend Answer: 10” bold black letters; 12’ in length

Question #5: Regarding Item 12 (Hull Anodes), how many and size Bolt on or weld on?

Answer: Bolt on type, like in kind, Stern: ZSS-12 Weld-On Zinc (4), Rudder 2: R-5 Camp (1 on each), Hull (Unknown), Shafts 2: X-11 Shaft Zinc Anode (1 on each), Keel Cooler 1: 1274A Zinc Anode for Fernstrum Keel Coolers

Question #6: What size impellers are needed and the model number? Item 18 Answer: Unknown

Question #7: What twin disc model numbers are the transmissions? Item 19 Answer: MG 5062 V

Question #8: Do the MDE’s have racor filters if so, what model Number are the racors? Item 20 Answer: Yes; 1000MA (x2), 500MA (x1)

Question #9: What type of heat exchanger does it have? Item 21 Answer: Not Known

Question #10: Please provide the serial numbers off of mde and gears to get the right parts priced .

Answer: MDES: Port- 84Z03684/Stbd- 84Z03685; MG 5062 V

Question #11: We need the size of the propellers for the bid additive Answer: 28x34

Question #12: Is a docking (haul blocking) available?

Answer: No

Question #13: What does the term “FLEET the vessel” refer too?

Answer: Refers to the repositioning of the blocks/stand while blast/painting the hull to ensure 100% coverage and application of the product being used.

140P5424Q0030 Amendment 1 Attachment 1

Question #14: Is a copy of a previous paint report available?

Answer: No

Question #15: Will the name be a vinyl overlay or is old name removed?

Answer: Remove old “NATIONAL PARK SERVICE” legend on both port and starboard side, replace with new (park will provide)

Question #16: Who will choose / approve non-slip aggregate coarseness?

Answer: The contracting officer’s representative (COR) after award.

Note: Any answers or clarifications that add to or change any information currently in the statement of work (SOW) will be incorporated before award. Acknowledgement of these answers demonstrates offeror’s receipt of updated info.

File details come from the government source that posted it. Updated .