This is a Lowest Price Technically Acceptable (LPTA) submission template for construction work under a Request for Quotation (RFQ). The template is designed for quoters to demonstrate technical acceptability and submit pricing for directional drilling and underground conduit installation projects. To receive a "PASS" rating and remain eligible for award, quoters must complete all required entries; any omission results in a "FAIL" rating and disqualification. Award will be made on an LPTA basis with no tradeoffs, evaluated according to criteria established in the solicitation.
The template requires quoters to provide: (1) company information including legal name, UEI, CAGE code, and primary point of contact; (2) evidence of relevant experience through two completed projects within the last five years involving directional drilling (HDD) and/or underground conduit installation, including customer name, location, project scope, timing, contract number, and reference contact; (3) identification of key subcontractors and their trades if specialized work will be subcontracted; (4) a SOW/Specs compliance checklist confirming compliance with five specific requirements: installing approximately 210 linear feet of 2.5-inch HDPE electrical conduit via directional drilling, installing four 4/0 AWG and one 4 AWG copper conductors, installing a 2-inch HDPE telecommunications conduit with pull tape and tracer wire, using only water-based drilling fluids with proper containment and offsite disposal, and using existing basement building penetrations with Contracting Officer approval for any modifications; and (5) signature and certification by an authorized representative. Each compliance item requires a binary Comply/Does Not Comply checkbox with optional notes explaining any inability to meet requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Template 3 — Construction (Under-SAT / LPTA)
ATTACHMENT X — LPTA TECHNICAL ACCEPTABILITY & PRICE SUBMISSION
TEMPLATE (CONSTRUCTION)
Project Name: Click or tap here to enter text.
Park Location:Click or tap here to enter text.
RFQ No.: Click or tap here to enter text.
INSTRUCTIONS (READ FIRST):
Quoter shall complete and submit this template with its quotation. To be rated Technically Acceptable (PASS), the quotation must include all required entries below. Omission of any required entry will result in Technically Unacceptable (FAIL) and ineligibility for award. The Government will make award on a Lowest Price Technically Acceptable (LPTA) basis; no tradeoffs. Evaluation will be on the basis established in the solicitation.
1) Quoter Information (Required)
• Legal name:Click or tap here to enter text.
• UEI (if applicable):Click or tap here to enter text.
• CAGE (if applicable):Click or tap here to enter text.
• Primary POC (name/title):Click or tap here to enter text.
• Email / Phone:Click or tap here to enter text.
2) Relevant Experience (PASS/FAIL) — Two (2) completed projects within last five (5) years
Each project must be relevant to the work Relevant to this requirement means: directional drilling (HDD) and/or underground conduit installation to a structure. Complete all fields:
Project 1
• Customer/Owner:Click or tap here to enter text.
• Location (city/state):Click or tap here to enter text.
• Relevance (check): ☐ HDD ☐ Underground conduit to a structure ☐ Both ☐
Other (explain) Click or tap here to enter text.
• Brief scope (1–3 sentences):
Click or tap here to enter text.
• Timing evidence (required): ☐Month/Year–Month/Year ☐ Year completed; Enter:Click or tap here to enter text.
• Contract/PO No. (if applicable):Click or tap here to enter text.
• POC name/title + email/phone:Click or tap here to enter text.
Project 2
• Customer/Owner:Click or tap here to enter text.
• Location (city/state):Click or tap here to enter text.
• Relevance (check): ☐HDD ☐ Underground conduit to a structure ☐ Both ☐ Other (explain) Click or tap here to enter text.
• Brief scope (1–3 sentences):
• Timing evidence (required): ☐Month/Year–Month/Year ☐ Year completed; Enter:Click or tap here to enter text.
• Contract/PO No. (if applicable):Click or tap here to enter text.
• POC name/title + email/phone:Click or tap here to enter text.
3) Key Subcontractor Identification (PASS/FAIL) — As applicable
• Will specialized work be subcontracted? ☐Yes ☐ No If yes, identify subcontractor(s) and role(s):
• Subcontractor name:Click or tap here to enter text.
• Trade/role (e.g., HDD):Click or tap here to enter text.
• City/state + phone/email:Click or tap here to enter text.
4) SOW/Specs Compliance Checklist (PASS/FAIL)
Mark one box per row (no blanks). Notes optional.
Minimum requirement SOW/specs
Comply
Does Not Comply
Notes (Why compliance can’t be achieved)
Requirement 1 (Electrical conduit)
Install approximately 210 LF of 2.5” HDPE SDR 11 electrical conduit using directional drilling; use sweeps/HDPE elbows at terminations; run must be one continuous pipe from transformer to building (no fused segments); install tracer wire; install at least 2 feet below grade or minimum depth required by NEC/Greeneville Energy Authority/local codes, whichever is greatest.
Click or tap here to enter text.
Requirement 2 (Electrical conductors)
Install four (4) 4/0 AWG conductors and one (1) 4 AWG ground; THWN-2 copper; 600V rating; 90°C wet/dry;
conductors must be one continuous run from electrical box to main disconnect (no splices).
Requirement 3 (Telecommunications conduit)
Install an additional 2” SDR 11 HDPE telecom conduit suitable for fiber optic cable using directional drilling; run must be one continuous pipe from location adjacent to transformer to building (no fused segments); install with 1500 lb pull tape and a tracer wire; install a new pull box adjacent to the transformer at the starting point of the telecom conduit run to the basement; use HDPE sweeps at terminations.
Requirement 4 (Directional drilling fluids / containment / disposal)
Only water-based drilling fluids may be used; prohibited components include diesel fuel, oil-based additives, petroleum-based lubricants, and any fluid/additive classified as hazardous; contractor must contain all drilling fluids/spoils, prevent discharge (including inadvertent returns), clean up daily and at completion, restore disturbed areas, and dispose of all drilling fluids/spoils at an approved offsite facility (no onsite burial/discharge).
Requirement 5 (Basement penetration / historic fabric protection)
Contractor shall use the existing building penetration in the basement for electricity (existing penetration is under the basement slab); if reuse is not feasible, contractor must submit to the CO the proposed new penetration location and the reasons existing cannot be reused, and obtain CO approval before performing any work; contractor must also provide a submittal detailing the proposed location of the telecom penetration.
5) Quoter Certification (Required)
• Authorized representative name/title:Click or tap here to enter text.
• Signature:
• Date:Click or tap here to enter text.