This document appears to be a set of demolition drawings and general notes for the rehabilitation of the Sugarlands Headquarters building, a historic property located within the Great Smoky Mountains National Park. The drawings provide details on the existing building conditions and the scope of demolition work required, including the removal of select interior finishes, equipment, and hazardous materials. Key points include:

The building is of historical significance, and all existing materials and finishes are to be treated as irreplaceable. Contractors must visit the site prior to bidding to familiarize themselves with the existing conditions. Demolition is to be carefully coordinated with the requirements for new construction. Hazardous materials abatement must follow the recommendations of the provided hazardous materials report. The contractor is responsible for the legal disposal of all demolished materials.

The related federal contract opportunity appears to be a solicitation for commercial moving services for the Great Smoky Mountains National Park. This is a combined synopsis/solicitation, and quotes are being requested rather than a full written solicitation document.

View the file

Other files

File Type Posted
Headquarters_Basement_Layout_0002.pdf PDF
Sol_140P5124Q0047_Amd_0002.pdf PDF
Headquarters_-_2nd_Floor_0002.pdf PDF
Headquarters_-_1st_Floor_0002.pdf PDF
Sol_140P5124Q0047_Amd_0001.pdf PDF
Sol_140P5124Q0047.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAIN LEVEL

1463' - 9"±

UPPER LEVEL

1474' - 1 1/2"±

LOWER LEVEL

1452' - 10 1/4"±

UPPER LEVEL (CENTER)

1474' - 9"±

LOWER LEVEL (EAST)

1453' - 3"±

ROOF @ EAST/WEST

WINGS

1485' - 6"±

ROOF @ CENTER WING

1491' - 9"±

ROOF @ CONNECTOR

WINGS

1483' - 11 1/4"±

02-40

02-40

02-40

02-4802-48

TYP.

TYP.

TYP.

02-48

TYP.

02-5302-54

02-5402-54 02-4502-45

02-69 TYP @ SOUTH

ELEVATION

1. THE GRSM SUGARLAND HEADQUARTERS IS A BUILDING OF HISTORICAL

SIGNIFICANCE. TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS

AS IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY INDICATED

HEREIN OR DIRECTED BY THE CONTRACTING OFFICER. PROTECT HISTORIC

FINISHES SLATED TO REMAIN FROM DAMAGE.

2. BIDDERS SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO BECOME

FAMILIAR WITH EXISTING CONDITIONS AND THE EXTENT OF MATERIAL AND

EQUIPMENT REMOVAL AT EACH FLOOR.

3. PROTECT EXISTING CONSTRUCTION TO REMAIN, INCLUDING HISTORIC FINISHES

SLATED TO REMAIN, FROM DAMAGE. PROVIDE TEMPORARY ENCLOSURES,

PROTECTION AND BARRICADES AS NECESSARY TO PROTECT AND SECURE THE

BUILDING.

4. FOR ALL EXISTING INTERIOR WALLS TO REMAIN, CONTRACTOR SHALL REMOVE

FINISHES AS WELL AS ALL ATTACHMENTS AND ACCESSORIES IN PREPERATION FOR

A NEW WALL FINISH, INCLUDING BUT NOT LIMITED TO WOOD PANELING AND BASE,

ANCHORS, CLIPS, BRACKETS, SIGNAGE, CORNER GUARDS, ADHESIVE STRIPS,

PLYWOOD BACKING, DOOR STOPS, REMNANTS OF CEILING GRID, FACE PLATES,

AND WALL CONDUIT, UNLESS OTHERWISE NOTED TO REMAIN. ALL SIGNAGE TO BE

SALVAGED AND HANDED OVER TO THE PARK .

5. WHERE EXISTING SHAFT WALLS AND CHASES ARE TO REMAIN, CONTRACTOR

SHALL REMOVE ADJACENT WALL CONSTRUCTION AS REQUIRED TO ACCESS PIPING

AND DUCTWORK BEYOND. MINIMIZE DAMAGE TO EXISTING WALL CONSTRUCTION

SLATED TO REMAIN TO THE EXTENT POSSIBLE.

6. VERIFY EXISTING FIELD CONDITIONS AND NOTIFY THE CONTRACTING OFFICER

OF INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS

BEFORE PROCEEDING WITH CONSTRUCTION OR DEMOLITION.

7. CONTRACTOR SHALL REMOVE ALL LOOSE AND DETERIORATED PLASTER FROM

ALL EXISTING WALLS AND CEILINGS TO REMAIN.

8. VERIFY EXISTING CONDITIONS AND SCOPE OF DEMOLITION WORK WITH

REQUIREMENTS FOR NEW CONSTRUCTION. COORDINATE SCOPE OF DEMOLITION

WITH REQUIREMENTS FOR NEW CONSTRUCTION SHOWN ON OTHER DRAWINGS.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXTENT OF

DEMOLITION THAT IS REQUIRED TO EXECUTE NEW WORK.

9. PERFORM SURVEY AND ANALYSIS OF EXISTING BUILDING PRIOR TO

COMMENCING WITH DEMOLITION OPERATIONS. DO NOT REMOVE CONSTRUCTION IF

THE STRUCTURAL INTEGRITY OF THE BUILDING MAY BE COMPROMISED UNTIL

APPROPRIATE TEMPORARY SUPPORTS ARE IN PLACE. GENERAL CONTRACTOR IS

FULLY RESPONSIBLE FOR DESIGN AND INSTALLATION OF ALL NECESSARY

SHORING AND BRACING OF EXISTING STRUCTURE REQUIRED FOR

IMPLEMENTATION OF DESIGN.

10. REMOVAL OF HAZARDOUS MATERIALS SHALL BE TREATED PER THE

RECOMMENDATIONS IN THE "SUGARLANDS HEADQUARTERS - HAZMAT REPORT -

E2187166" ." SEE ALSO SHEETS G04 - G06 ASBESTOS REMEDIATION PLANS

11. CONTRACTOR IS RESPONSIBLE FOR THE LEGAL DISPOSAL OF ALL DEMOLISHED

MATERIALS.

12. GENERAL CONTRACTOR SHALL COORDINATE ALL DISCONNECTS AND SHUT

OFFS THAT MAY BE REQUIRED FOR DEMOLITION.

13. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHTING IN

ALL AREAS.

14. LEAVE FLOOR IN BROOM CLEAN CONDITION AND READY FOR CONSTRUCTION;

TYPICAL FOR ALL AREAS OF WORK. CONTRACTOR SHALL REMOVE ALL EXISTING

LOOSE MATERIALS, DEBRIS, AND WASTE FROM EACH FLOOR, INCLUDING DEBRIS

AND LITTER LOCATED IN PLUMBING CHASES AND SHAFTS.

15. REMOVE ELECTRICAL COMPONENTS TO EQUIPMENT SLATED FOR DEMOLITION.

PANELS, FIXTURES, CONDUIT, WIRING, ETC. BACK TO SERVICE ENTRY

POINT/METER. COORDINATE EXTENT WITH ELECTRICAL DEMOLITION DRAWINGS.

16. REMOVE MECHANICAL/PLUMBING EQUIPMENT SLATED FOR DEMOLITION

INCLUDING ALL ASSOCIATED PIPING BACK TO SERVICE ENTRY POINT/METER.

COORDINATE EXTENT WITH MECHNICAL/PLUMBING DEMOLITION DRAWINGS.

17. REMOVE MECHANICAL/HVAC EQUIPMENT SLATED FOR DEMOLITION INCLUDING

ALL ASSOCIATED PIPING, RADIATORS, AND DUCTWORK. REMOVE PIPING BACK TO

SERVICE ENTRY POINT/METER. COORDINATE EXTENT WITH

MECHANICAL/PLUMBING DEMOLITION DRAWINGS.

18. SAWCUT EXISTING STRUCTURE AS NOTED. COORDINATE WITH STRUCTURAL

DRAWINGS.

19. EXPOSED STRUCTURE TO BE INSPECTED AND REPAIRED AS REQ.

20. REFER TO GENERAL NOTES S-001 FOR ADDITIONAL STRUC. INFO.

MAIN LEVEL

1463' - 9"±

UPPER LEVEL

1474' - 1 1/2"±

LOWER LEVEL

1452' - 10 1/4"±

ROOF @ EAST/WEST

WINGS

1485' - 6"±

02-48

TYP.

TYP.

02-48

02-40

02-5802-58 EXIST. SLATE ROOF,

SEE ROOF PLANS

EXIST. MASONRY TO

REMAIN

REMOVE EXISTING

ASBESTOS CONTAINING

SEALANT.

FERROUS ELEMENT

TO REMAIN

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO. TITLE OF SHEET

LEGEND

GENERAL NOTESKEY NOTESGENERAL NOTES

A/E FIRM:

OF

PKG.

NO.

SHEET

DRAWING NO.

146799

KEY NOTES

LH/KB

LH/KB

D20PMR

03/05/2021

DEMOLITION

EXTERIOR

ELEVATIONS

REHABILITATE SUGARLANDS HEADQUARTERS

GREAT SMOKY MOUNTAINS NATIONAL PARK

ARCHITECT:

ANN ARBOR, MI

DETROIT, MI

REFERRED FROM:1/8" = 1'-0"D20 D01

2 SOUTH EXTERIOR ELEVATION DEMOLITION

02-40 IN AREAS NOT INDICATED TO BE RE-ROOFED REMOVE ANY DAMAGED AND/OR BROKEN SLATE SHINGLES, REMOVE WOOD NAILERS AT EDGES OF SLOPED AND

GABLED ROOFS (APPROXIMATELY 12 INCHES FROM EDGE).

02-45 EXISTING LIGHT FIXTURE TO REMAIN. PROTECT DURING CONSTRUCTION.

02-48 REMOVE EXISTING ASBESTOS CONTAINING SEALANT AT SEAMS. REFER TO HAZMAT DRAWINGS.

02-53 EXISTING LOUVER TO BE REMOVED. PREP OPENING FOR NEW WINDOW

02-54 EXISTING WINDOW (BEYOND) TO REMAIN

02-58 ELEC. EQUIPMENT TO BE REMOVED. COORDINATE WITH ELEC. DRAWINGS.

02-69 EXISTING SHUTTERS TO REMAIN, PROTECT DURING CONSTRUCTION.

REFERRED FROM:1/8" = 1'-0"D20 D01

1 WEST EXTERIOR ELEVATION DEMOLITION

MAIN LEVEL

1463' - 9"±

UPPER LEVEL

1474' - 1 1/2"±

LOWER LEVEL

1452' - 10 1/4"±

LOWER LEVEL (EAST)

1453' - 3"±

ROOF @ EAST/WEST

WINGS

1485' - 6"±

ROOF @ CENTER WING

1491' - 9"±

ROOF @ CONNECTOR

WINGS

1483' - 11 1/4"±

02-40

02-40

02-40

TYP.

TYP.

TYP.

EXIST DOOR

BEYOND

02-48

02-48

02-25

02-48

TYP.

02-55

02-56

02-5602-56

02-42

02-42 02-42

MAIN LEVEL

1463' - 9"±

UPPER LEVEL

1474' - 1 1/2"±

LOWER LEVEL (EAST)

1453' - 3"±

ROOF @ EAST/WEST

WINGS

1485' - 6"±

02-4802-40

TYP. TYP.

EXIST. SLATE ROOF,

SEE ROOF PLANS

EXIST. MASONRY TO

REMAIN

REMOVE EXISTING

ASBESTOS CONTAINING

SEALANT.

FERROUS ELEMENT

TO REMAIN

1. THE GRSM SUGARLAND HEADQUARTERS IS A BUILDING OF HISTORICAL

SIGNIFICANCE. TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS

AS IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY INDICATED

HEREIN OR DIRECTED BY THE CONTRACTING OFFICER. PROTECT HISTORIC

FINISHES SLATED TO REMAIN FROM DAMAGE.

2. BIDDERS SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO BECOME

FAMILIAR WITH EXISTING CONDITIONS AND THE EXTENT OF MATERIAL AND

EQUIPMENT REMOVAL AT EACH FLOOR.

3. PROTECT EXISTING CONSTRUCTION TO REMAIN, INCLUDING HISTORIC FINISHES

SLATED TO REMAIN, FROM DAMAGE. PROVIDE TEMPORARY ENCLOSURES,

PROTECTION AND BARRICADES AS NECESSARY TO PROTECT AND SECURE THE

BUILDING.

4. FOR ALL EXISTING INTERIOR WALLS TO REMAIN, CONTRACTOR SHALL REMOVE

FINISHES AS WELL AS ALL ATTACHMENTS AND ACCESSORIES IN PREPERATION FOR

A NEW WALL FINISH, INCLUDING BUT NOT LIMITED TO WOOD PANELING AND BASE,

ANCHORS, CLIPS, BRACKETS, SIGNAGE, CORNER GUARDS, ADHESIVE STRIPS,

PLYWOOD BACKING, DOOR STOPS, REMNANTS OF CEILING GRID, FACE PLATES,

AND WALL CONDUIT, UNLESS OTHERWISE NOTED TO REMAIN. ALL SIGNAGE TO BE

SALVAGED AND HANDED OVER TO THE PARK .

5. WHERE EXISTING SHAFT WALLS AND CHASES ARE TO REMAIN, CONTRACTOR

SHALL REMOVE ADJACENT WALL CONSTRUCTION AS REQUIRED TO ACCESS PIPING

AND DUCTWORK BEYOND. MINIMIZE DAMAGE TO EXISTING WALL CONSTRUCTION

SLATED TO REMAIN TO THE EXTENT POSSIBLE.

6. VERIFY EXISTING FIELD CONDITIONS AND NOTIFY THE CONTRACTING OFFICER

OF INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS

BEFORE PROCEEDING WITH CONSTRUCTION OR DEMOLITION.

7. CONTRACTOR SHALL REMOVE ALL LOOSE AND DETERIORATED PLASTER FROM

ALL EXISTING WALLS AND CEILINGS TO REMAIN.

8. VERIFY EXISTING CONDITIONS AND SCOPE OF DEMOLITION WORK WITH

REQUIREMENTS FOR NEW CONSTRUCTION. COORDINATE SCOPE OF DEMOLITION

WITH REQUIREMENTS FOR NEW CONSTRUCTION SHOWN ON OTHER DRAWINGS.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXTENT OF

DEMOLITION THAT IS REQUIRED TO EXECUTE NEW WORK.

9. PERFORM SURVEY AND ANALYSIS OF EXISTING BUILDING PRIOR TO

COMMENCING WITH DEMOLITION OPERATIONS. DO NOT REMOVE CONSTRUCTION IF

THE STRUCTURAL INTEGRITY OF THE BUILDING MAY BE COMPROMISED UNTIL

APPROPRIATE TEMPORARY SUPPORTS ARE IN PLACE. GENERAL CONTRACTOR IS

FULLY RESPONSIBLE FOR DESIGN AND INSTALLATION OF ALL NECESSARY

SHORING AND BRACING OF EXISTING STRUCTURE REQUIRED FOR

IMPLEMENTATION OF DESIGN.

10. REMOVAL OF HAZARDOUS MATERIALS SHALL BE TREATED PER THE

RECOMMENDATIONS IN THE "SUGARLANDS HEADQUARTERS - HAZMAT REPORT -

E2187166" ." SEE ALSO SHEETS G04 - G06 ASBESTOS REMEDIATION PLANS

11. CONTRACTOR IS RESPONSIBLE FOR THE LEGAL DISPOSAL OF ALL DEMOLISHED

MATERIALS.

12. GENERAL CONTRACTOR SHALL COORDINATE ALL DISCONNECTS AND SHUT

OFFS THAT MAY BE REQUIRED FOR DEMOLITION.

13. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHTING IN

ALL AREAS.

14. LEAVE FLOOR IN BROOM CLEAN CONDITION AND READY FOR CONSTRUCTION;

TYPICAL FOR ALL AREAS OF WORK. CONTRACTOR SHALL REMOVE ALL EXISTING

LOOSE MATERIALS, DEBRIS, AND WASTE FROM EACH FLOOR, INCLUDING DEBRIS

AND LITTER LOCATED IN PLUMBING CHASES AND SHAFTS.

15. REMOVE ELECTRICAL COMPONENTS TO EQUIPMENT SLATED FOR DEMOLITION.

PANELS, FIXTURES, CONDUIT, WIRING, ETC. BACK TO SERVICE ENTRY

POINT/METER. COORDINATE EXTENT WITH ELECTRICAL DEMOLITION DRAWINGS.

16. REMOVE MECHANICAL/PLUMBING EQUIPMENT SLATED FOR DEMOLITION

INCLUDING ALL ASSOCIATED PIPING BACK TO SERVICE ENTRY POINT/METER.

COORDINATE EXTENT WITH MECHNICAL/PLUMBING DEMOLITION DRAWINGS.

17. REMOVE MECHANICAL/HVAC EQUIPMENT SLATED FOR DEMOLITION INCLUDING

ALL ASSOCIATED PIPING, RADIATORS, AND DUCTWORK. REMOVE PIPING BACK TO

SERVICE ENTRY POINT/METER. COORDINATE EXTENT WITH

MECHANICAL/PLUMBING DEMOLITION DRAWINGS.

18. SAWCUT EXISTING STRUCTURE AS NOTED. COORDINATE WITH STRUCTURAL

DRAWINGS.

19. EXPOSED STRUCTURE TO BE INSPECTED AND REPAIRED AS REQ.

20. REFER TO GENERAL NOTES S-001 FOR ADDITIONAL STRUC. INFO.

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO. TITLE OF SHEET

LEGEND

GENERAL NOTESKEY NOTESGENERAL NOTES

A/E FIRM:

OF

PKG.

NO.

SHEET

DRAWING NO.

146799

KEY NOTES

LH/KB

LH/KB

D21PMR

03/05/2021

DEMOLITION

EXTERIOR

ELEVATIONS

REHABILITATE SUGARLANDS HEADQUARTERS

GREAT SMOKY MOUNTAINS NATIONAL PARK

ARCHITECT:

ANN ARBOR, MI

DETROIT, MI

REFERRED FROM:1/8" = 1'-0"D21 D01

2 NORTH EXTERIOR ELEVATION DEMOLITION

REFERRED FROM:1/8" = 1'-0"D21 D01

1 EAST EXTERIOR ELEVATION DEMOLITION

02-25 REMOVE EXIST. ESCAPE PLATFORM, LADDER, AND ALL ASSOCIATED CONNECTIONS.

02-40 IN AREAS NOT INDICATED TO BE RE-ROOFED REMOVE ANY DAMAGED AND/OR BROKEN SLATE SHINGLES, REMOVE WOOD NAILERS AT EDGES OF SLOPED AND

GABLED ROOFS (APPROXIMATELY 12 INCHES FROM EDGE).

02-42 REMOVE LIGHT FIXTURE, COORDINATE WITH ELEC.

02-48 REMOVE EXISTING ASBESTOS CONTAINING SEALANT AT SEAMS. REFER TO HAZMAT DRAWINGS.

02-55 EXISTING LOUVER TO REMAIN

02-56 EXISTING ANTENNA TO REMAIN