233050-Industrial_Hygiene_Monitoring-final_0001.pdf
PDF 635 KB Posted
- Solicitation number
- 140P4224Q0115
About this file
This document is an industrial hygiene monitoring report prepared by Criterion Laboratories, Inc. for the Valley Forge National Historical Park. The purpose was to evaluate airborne concentrations of cresols adjacent to stored items coated with creosote. Air monitoring was conducted on December 14, 2023, and the results indicated cresol concentrations below the detection limit and well below OSHA and NIOSH exposure limits. The report concludes that the air quality within the barn has not been significantly impacted by the stored creosote-coated materials.
The related federal contract opportunity is for the conservation of wooden artifacts at the Valley Forge National Historical Park in King of Prussia, Pennsylvania. The solicitation number is 140P4224Q0115 and the procuring agency is the Department of the Interior National Park Service Northeast Region. No additional details about the scope, pricing, or timeline of this contract opportunity are provided in the information given.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P4224Q0115_Amd_0001.pdf | ||
| VAFO_upper_forge_contractor_Q_A_0001.docx | DOCX document | |
| Wage_Determination_WD_15-5791_Rev_26.pdf | ||
| Statement_of_Work.docx | DOCX document | |
| Price_Schedule.docx | DOCX document | |
| Sol_140P4224Q0115.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
400 Street Road, Bensalem, PA 19020 / 215-244-1300 / Fax 215-244-4349 www.criterionlabs.com
At:
1060 Knox Tindle Lane
Tredyffrin Township, PA 19087
For:
Hannah Sanner
Vally Forge National Historical Park
1400 North Outer Line Drive
King of Prussia, PA 19406
Prepared By:
Mr. Eric Wysocki
Project Manager
Report Date:
December 21, 2023
Project Number:
233050
Date of Project:
December 14, 2023
INDUSTRIAL
HYGIENE
MONITORING
Field
Services
Lab
Training
Industrial Hygiene Monitoring
Valley Forge National Historical Park Criterion Laboratories, Inc.
TABLE OF CONTENTS
Section Number
1.0 Executive Summary
1.1 Purpose
1.2 Personnel
1.3 Conclusions
2.0 Project Overview
2.1 Procedures
2.2 Measurement Results
2.3 Discussion
3.0 Analytical Results
1.0 EXECUTIVE SUMMARY
1.0 EXECUTIVE SUMMARY
1.1 Purpose
Criterion Laboratories, Inc. (Criterion) was requested by Hannah Sanner of Valley Forge
National Historical Park to perform air monitoring for cresols at 1060 Knox Tindle Lane in Tredyffrin Township, PA.
The purpose of the monitoring was to evaluate airborne concentrations of cresols adjacent to stored items coated with creosote. Air monitoring was conducted on December 14, 2023.
1.2 Personnel
The monitoring was performed by Ms. Julie Mui, Certified Industrial Hygienist (CIH) of
Criterion. The report was written by Mr. Eric Wysocki, Project Manager and reviewed by Mr. Michael Panepresso, VP of Operations, both of Criterion.
1.3 Conclusions
Area samples collected in the barn, adjacent to creosote coated materials, indicated cresols concentrations below the detection limit of the analytical method. Concentrations were well below the Occupational Safety and Health Administration (OSHA) Permissible exposure Limit (PEL of 5 parts per million (ppm) and the National Institute for
Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) of 2.3 ppm.
The results indicate air quality within the barn has not been significantly impacted by the stored creosote coated materials.
Written By: Reviewed By:
Eric Wysocki Michael Panepresso
Project Manager VP of Operations
2.0 PROJECT OVERVIEW
2.0 PROJECT OVERVIEW
2.1 Procedures
Area sampling for creosote was conducted using battery powered pumps calibrated at approximately 0.2 lpm connected with a section of tygon tubing to an
XAD 7 sorbent tube. The samples were analyzed for cresols by EMSL Analytical in Cinnaminson, NJ in accordance with the NIOSH 2546 method.
2.2 Measurement Results
Results of the monitoring are found in the Analytical Results section of this report, and are summarized as follows:
Area monitoring conducted in the barn indicated cresols concentrations of < 0.18 parts per million (ppm).
2.3 Discussion
Airborne concentrations of creosote in the barn were below the detection limit of the analytical method as well as the OSHA PEL and NIOSH REL. The results indicate air quality within the barn has not been significantly impacted by the stored creosote coated materials.
Creosote coated materials should not be burned, otherwise the compound may become an inhalation hazard. Special disposal requirements might be required for creosote coated materials.
3.0 ANALYTICAL RESULTS
EMSL Analytical, Inc. 200 Route 130 North Cinnaminson, NJ 08077
Order ID: 282304743
Attn: Eric Wysocki
Criterion Laboratories, Inc.
400 Street Road
Bensalem, PA 19020
Customer ID:
Customer PO:
Date Received:
CRIT52
12/14/23
Project: 233050 – Valley Forge National Park EMSL Project ID:
Report Date: 12/19/23 Date Analyzed: 12/18/23
Test Report – Cresol Analysis by GC/FID of Solid Sorbent tubes via NIOSH
Method 2546, Issue 1, 8/15/94
Notes:
1. Samples were received in acceptable condition unless otherwise noted.
2. These results relate only to the samples tested.
3. Sample results are not blank corrected unless otherwise noted.
4. Discernable field blank(s) submitted with samples if listed.
BJ
Analyst
Sample ID Identification Component Volume
(L)
Sample
Weight
(mg)
Sample
Conc.
(mg/m3)
Sample
Conc.
(PPM)
Reporting
Limit
(mg/m3)
282304743-0001 233050-01; Barn – By
Shelving Units o-Cresol 12.40
<0.010 <0.81 <0.18 0.81 m,p-Cresol <0.010 <0.81 <0.18 0.81
282304743-0002 233050-02; Barn – By
Creosote Samples on Floor o-Cresol 12.60
<0.010 <0.79 <0.18 0.79 m,p-Cresol <0.010 <0.79 <0.18 0.79
Desorption
Blank o-Cresol
<0.010 N/A N/A N/A m,p-Cresol <0.010 N/A N/A N/A
* EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL.
EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
OrderID: 282304743