This is a set of architectural design drawings for the Caesar Rodney Statue Relocation project at Freedom Plaza in the National Mall and Memorial Parks. The drawings, dated 02/23/2026, were designed by the National Park Service (NPS) in-house design team with technical review by the NPS/NCR/FDC.

The project involves relocating the bronze Caesar Rodney statue to a new pedestal base at Freedom Plaza on Pennsylvania Avenue N.W. The base design includes a reinforced concrete foundation with a solid cast concrete base, followed by a concrete masonry unit (CMU) structural base with a tinted glass-fiber reinforced concrete (GFRC) veneer. The pedestal features horizontal coursing with 1-inch wide and 3/8-inch deep joints, with color coordinated to the plaza canal paving. The cap assembly includes an anti-scale cast concrete cornice with a 1-inch drip edge, sealed joints between the GFRC and concrete components, and the statue name mounted in bronze with other lettering incised into the GFRC. The overall base dimensions are 15'-9½" by 7'-6½". All exposed masonry surfaces must be treated with Graffiti Solutions Shield Max anti-graffiti coating. The statue connection and final attachment of the cap to the structural base will be designed and executed by the contractor. Site-specific design elements include sloped surfaces to discourage climbing, and elevation details showing a height of approximately 17.23 feet at the plaza level.

View the file

Other files for this federal contract opportunity

Other files attached to HPTC NCR CEASAR RODNEY STATUE, newest first.
File Type Posted
Sol_140P2126Q0070_Amd_0003.pdf PDF
Rodney_New_Location_0003.png PNG image
Aerial_view-Freedom_Plaza-Statue_location-annotated_0002.jpg JPG image
Sol_140P2126Q0070_Amd_0002.pdf PDF
Caesar_Rodney_0001.jpeg JPEG file
Questions_and_Answers_0001.pdf PDF
Sol_140P2126Q0070_Amd_0001.pdf PDF
Caesar_Rodney_1_0001.jpeg JPEG file
Attachment_2__SCA_Wage_Determination_2015-4215_(DE).pdf PDF
Attachment_1_NAMA_Caesar_Rodney__Crane_SOW.pdf PDF
Sol_140P2126Q0070.pdf PDF
Attachment_3__SCA_Wage_Determination_2015-4281_(DC).pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T-oj••

1'"

JOINT PROFILE

SCALE 1 11 = 1 1-011

EQ.

S CORNICE SECTION

SCALE 1 /211 = 1 1-011

CAESAR RODNEY

GENERAL NOTE: ALL EXPOSED SURFACES OF

MASONRY BASE TO BE TREATED WITH GRAFFITI

SOLUTIONS SHIELD MAX ANTI GRAFFITI COATING.

BRONZE RODNEY STATUE

SLOPED TO DISCOURAGE CLIMBING

ANTI-SCALE CAST CONCRETE CORNICE

SIGNER OF THE DECLARATION OF INDEPENDENCE~-~=--- NAME MOUNTED IN BRONZE, OTHER LETTERING INCISED

INTO GFRC

EQ.

EQ.

---=,=±= )==='"===c==;====='=====:

I

EQ.

TRANSVERSE ELEVATION

SCALE 1 /411 = 1 1-011

1!1'-9:J:"'

1:z•-2:J:"'

TOP SLAB 12'-2 ;" X 3'-11 ;"

SECOND STEP OF CAP 12'-5 ;" X 4'-2 ;"

r"'I~

OUTSIDE EDGE OF CORNICE 12'-11 ;" X 7'-6 ;"

t----._ PRECAST BASE 15'-9 ~" x 7'-6 ~"

I 12'-5t

I

® CAP DIAGRAM

2 SCALE 1 /411 = 1 1-011

LONGITUDINAL ELEVATION

SCALE 1 /411 = 1 1-011

I

J'-11t'

I

I

0BASEAPLAN

i SCALE 1 /411 = 1 1-011

HORIZONTAL COURSING 111 WIDE, ; 11 DEEP

TINTED GFRC, COORDINATE COLOR WITH PLAZA CANAL

PAVING

LOWEST COURSE IN CAST CONCRETE

EDGE OF CORNICE

CONCRETE MASONRY STRUCTURAL BASE

GFRC VENEER BASE

NPS IN-HOUSE DESIGN DESIGNED, SUB SHEET NO. TITLE OF SHEET DRAWING NO.

EAM CAESAR RODNEY RELOCATION

X

PRl ~E/ARCH:

NPS/NCR/FDC CADD, X

EAM PMIS/PKG NO.

TECH. REVIEW,

A 2 FREEDOM PLAZA X

RS SHEET

DATE: rev.

2 3 02/23/2026 NATIONAL MALL AND MEMORIAL PARKS OF - -