This document is an amendment to Solicitation 140P2124R0060 for the MORU - AV System Upgrade project. The purpose of this amendment is to incorporate answers and photos to Requests for Information (RFIs) that were submitted. The solicitation is seeking upgrades to the audio-visual system at the Mount Rushmore National Memorial amphitheater and indoor theaters. Key details include:

The amphitheater can be accessed by vehicle, and a small manlift can be used for the installation. The expectation is for a permanent LED video wall that fits within the 16:9 ratio of the amphitheater opening. Detailed dimensions of the amphitheater and existing speaker tower locations are provided. The existing audio system uses multiple language transmitters, but the future system only requires single language capabilities. Tower worker certifications are required. The indoor theaters are identical, and there is limited space behind the screen wall to add a center channel speaker. The outdoor amphitheater system is designed for 5.1 surround sound. Offerors are expected to propose solutions for screen positioning and projector mounting. All other terms and conditions of the original solicitation remain unchanged.

View the file

Other files for this federal contract opportunity

Other files attached to HAFC_MORU_323426_AV SYSTEM UPGRADE, newest first.
File Type Posted
Attachment_C_-_Amphitheater_Drawings.pdf PDF
Attachment_A_-_Standard_Specs_for_AV_March_2024.docx DOCX document
Sol_140P2124R0060.pdf PDF
Attachment_E_-_PricingSheet.xlsx XLSX spreadsheet
Attachment_B_-_Theater_Drawings.pdf PDF
Attachment_D_-_Photos.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(x)

140P2124R0060 x x

1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR

OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

x

PHF

Harpers Ferry WV 25425 IDC Building 67 Mather Place DOI, NPS, HFC - Acquisition Managem

PWA

Denver CO 80225 P.O.Box 25287 MS WCP NPS, WASO - WCP Contracting

07/18/20240001

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

FACILITY CODE CODE

10B. DATED (SEE ITEM 13)

10A. MODIFICATION OF CONTRACT/ORDER NO.

9B. DATED (SEE ITEM 11)

9A. AMENDMENT OF SOLICITATION NO.

CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY

PAGE OF PAGES

4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)

1. CONTRACT ID CODE

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

07/03/2024

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.

ORDER NO. IN ITEM 10A.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

The purpose of this amendment is to incorporate answers/photos to Requests for Information

(RFIs) that were due on 07/16/2024.

All other terms and conditions of this solicitation remain the same.

//END OF AMENDMENT//

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED

(Signature of person authorized to sign) (Signature of Contracting Officer)

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

Previous edition unusable

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .

Requests for Information (RFI) for Solicitation 140P2124R0060: MORU – AV System Upgrade

1. Can the amphitheater be reached by vehicle?

Answer: Yes.

2. Can a lift be used for the installation at the amphitheater?

Answer: Yes. A small manlift with a max working height of 20-25 ft can be maneuvered on to the stage and used inside the building.

3. Is the amphitheater projector to be mounted on the back wall, ceiling, truss, floor mounted?

Answer: Floor.

4. The RFQ is requesting an optional video wall for the amphitheater. A video wall cannot be “rolled up”, like a screen. If this option were selected, what are the expectations on covering the entire opening?

Answer: Expectation is the LED wall would remain assembled and be the maximum size that would utilize the 16:9 ratio and fit inside the doors of the amphitheater. The LED Wall would be protected from weather.

The support structure for the LED wall would be permanent, not movable. Components of the wall should be easily maintained and accessible from the front and back. The wall should include a high output processor/controller.

5. Please provide dimensions of the amphitheater. (Length, width at front, width at rear and rise from front seats to rear seats.) These dimensions are needed to provide an accurate computer generated coverage map.

Answer: All measurements are within +/- 5'. Length = 167' from the screen to the back row. Width at front of stage = 90'. Width at last row = 164'. Rise from front to rear is approximately 30-35 degrees.

6. Can you please provide the height and location of the existing towers?

Answer: There are four towers, two front and two rear. The two front towers are aligned with the front row and are 122' apart. The two rear towers are aligned with the start of the rear seating section and are 171' apart. Distance between the front and rear towers is 114'.

Tower heights of the Washington side front tower is 23'7", Washington side back tower is 16'10". Lincoln side front tower is 40' and Lincoln side back tower is 26'. All measurements approximate. Disparate heights are due to uneven ground.

The top of the front towers are approximately 6-8 feet above the front row. Front row and stage are level with one another.

The top of the rear towers is about even with rear seating.

7. Can you please provide the existing speaker manufacturer and model numbers for the amphitheater system?

Answer: Unknown.

8. Are the subwoofers the speakers located on the front left and right of the building?

Answer: No. The subwoofer is mounted above the center speaker.

9. Can you provide pictures of the base of each of the towers?

Answer: Towers are mounted the exact same way. They are secured in concrete.

10. How far are the towers from the concrete skirt of the stage area?

Answer: Approximately 15'.

11. Can you provide pictures from below the speakers to see how the lighting par cares are mounted in relationship to the speakers on the towers?

Answer: See attached photos.

12. Are there multiple languages being transmitted in each system? (There are five Listen transmitters in each existing system.) If so, will we need to continue to transmit in multiple languages?

Answer: Yes to multiple languages currently transmitted. No to multiple languages in the future.

13. Please provide more information regarding “tower certification” as indicated on Pg 7.

Answer: Tower certifications for tower workers are available through multiple associations and organizations. Standard cortication nomenclatures include Authorized Climber/Rescuer and Competent Climber/Rescuer. Authorized Climbers must be under supervision by a Competent Climber. Expectation is certification costs are included in the offerors bid.

14. Is there conduit for pulling new cable to the existing towers?

Answer: Yes.

15. Please provide more information regarding “third-party” mixing. Is the customer wanting just inputs into the system, or is the customer wanting a mixing console to connect to the speaker system? If a console is desired, please provide specifications.

Answer: Inputs. Guest will provide their own mixer.

16. Are both indoor theaters the exactly the same? (Only pictures of one theater was provided)

Answer: Yes.

17. Can you provide the dimensions of the current indoor theater speaker enclosures. (height, width and depth)

Answer: Each enclosure is approximately 2' square and 1' deep.

18. Is there room behind the current screen (indoor theaters) wall to add the center channel behind the screen? What are the dimensions behind the wall? Can pictures be provided?

Answer: The screen wall is a free-standing wood frame structure. Distance from the rear of the screen wall to the rear wall is approximately 4'. No pictures available currently.

19. Is there conduit from the booths (indoor theaters) to the existing speaker locations?

Answer: Yes.

20. Can you please confirm that the outdoor amphitheater system is designed to reproduce a surround encoded file and that the rear speaker towers are not just delay fill speakers.

Answer: Current movie shown is 5.1 surround.

21. Please provide the distance between each tower and the concrete walkway.

Answer: Tower to walkway is approximately 15'.

22. Can you drive to each sound tower?

Answer: No.

23. With the potential damage of affixing the electric screen surface to the ground in some way, would a permanent snap screen be an option? The screen could be winched out of position (controlled by iPad control system) to the ceiling or on wheels to roll out of the way.

Answer: Offeror to propose a design.

24. Please provide door opening size for the outdoor amphitheater (To determine correct extra screen drop if needed).

Answer: Approximately 25' wide by 20' high.

25. Does the mount for the projector need to be a ceiling mount? I don’t see in the pictures where the projector is located.

Answer: Projectors in theaters and amphitheater sit on crates off the floor.