B09_140P2119Q0013_QUESTIONS_&_ANSWERS_AM_0001.pdf
PDF 131 KB Posted
- Solicitation number
- 140P2119Q0013
About this file
Questions & Answers - Amendment 0001
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B09_140P2119Q0013_QUESTIONS_&_ANSWERS_AM_0002.pdf | ||
| B09_140P2119Q0013_SF_30_AM_0002.pdf | ||
| B09_ATT_5_PROPOSAL_SUBMISSION_PACKAGE.rtf | RTF text file | |
| B09_140P2119Q0013_SF_30_AM_0001.pdf | ||
| B08_ATT_3_Picture_attachment.zip | ZIP file | |
| B08_ATT_2_Past_Performance_Questionnaire_Vol_I.docx | DOCX document | |
| B08_ATT_1_SOW_Elastomeric_Roof.pdf | ||
| B08_ATT_4_WAGE_DETERMINATIONS_1_4_19.pdf | ||
| B08_-_140P2119Q0013.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation 140P2119Q0013/Amendment 0001 Elastomeric Roof on Nelson Hall NCTTP
Questions & Answers
1. There is no mention of which roof coating item you want to use with this SureCoat system- need to know for pricing? Is it the Cross-Linked Elastomeric Roof Coating that you wanted use? Please specify
Answer: When the SureCoat system or equal was specified, this referred to the base system, cleaner, basic Surecoat as coating and then their poly mesh, polyester reinforcement. There is a SureSet coating which hardens quickly. It was not specified but may be proposed pursuant to each offeror’s proposed means and methods. If a system alternate to SureCoat can provide a 10 year warranty and meet the same salient characteristics, this may be proposed as an equal.
2. Can you please send me the “Plans and Spec’s” for the project?
Answer: Everything is available on the FBO website. There's an option where you can download all the attachments as one zipped file to make it easier. Please be sure to note all the submission requirements in Section L. Specifications and pictures are available in Attachments 1 and 3.
3. Is there any specific format or table to be used for Volume II?
Answer: Section L of the solicitation has the instructions and submission requirements on what is needed to be submitted in Volume II
4. Do you happen to accept “Contractors Qualification Statement” (AIA305) in lieu of the “Past Performance Questionnaire”?
Answer: In order to consistently rate each contractor, the no alternate Past Performance Questionnaires may be submitted.
5. Are Alternate roofing systems allowed to be proposed?
Answer: See answer to Question 1. This RFQ includes provision 52.211-6 Brand Name or Equal, and equivalent systems that meet all salient characteristics and provide an equal or greater warranty period may be proposed. Offerors shall utilize the Equals form provided in this amendment.
6. For the product is it acrylic or solvent based coating?
Answer: The Surecoat system specified is a hybrid system but it has acrylic in it and can be considered acrylic with a perm rating of less than 1. Surecoat has a perm rating of .25, but a system with a perm rating of less than one will keep water out and meet the required salient characteristics of the specifications. A solvent based system will not be accepted, as it will cause damage to the existing roof.