B08_-_Attachment_1_-_SOW_-_GRTE_Colter_Bay_1103_Spray_Foam.pdf
PDF 491 KB Posted
- Attached to
- GRTE: APPLY SPRAY FOAM INSULATION - GRAND TETON NP Federal contract opportunity
- Solicitation number
- 140P1424Q0024
About this file
This document contains a statement of work and related federal contract opportunity for spray foam insulation services. The National Park Service is seeking a contractor to install approximately 1,000 square feet of closed cell spray foam insulation with an R-value of R-50 on the roof trusses and vertical wall surfaces above log walls of a small two-bedroom log cabin located at 624 Aspen Loop in Moran, Wyoming. The selected contractor will provide all necessary materials and labor to complete the job, cover any sprinkler heads to prevent overspray, and be responsible for all cleanup. The solicitation number for this opportunity is 140P1424Q0024 and it is being issued by the Department of the Interior National Park Service Intermountain Region to spray foam insulate structure 1103 at Grand Teton National Park in Colter Bay, Wyoming.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P1424Q0024_Amd_0001.pdf | ||
| Sol_140P1424Q0024.pdf | ||
| B03_-_WD_WY20230017_-_17NOV23.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The National Park Service
Park: Grand Teton, WY
Project: Colter Bay 1103 Spray Foam
Address: 624 Aspen Loop, Moran WY, 83013
Date: 18 December 2023
Statement of Work (SOW)
Install spray foam insulation on approximately 1000 SQ feet of 2X8 trussed roof surface. This includes flat vertical areas of the roof above the log walls. The bottom surface of the truss should be left with no foam so the wood can breathe.
Spray approximately 7.5 inches of closed cell spray foam to achieve a R value of roughly R-50.
Provide all materials and labor to complete the job. All cleanup will be the responsibility of the contractor. Sprinkler heads are already installed and will need to be covered to avoid any over spray.
No Government Furnished Materials will be provided.
Job site is located in Colter Bay: 1103 is a small 2-bedroom log cabin with new engineered trusses. 624 Aspen Loop, Moran WY, 83013.
Spray vertical Wall surfaces above the log walls.
Cover all sprinkler heads to avoid over spray.
Leave bottom surface of 2 x 8 truss unsprayed to allow wood to breathe.