Amendment_0002_0002.pdf
PDF 1 MB Posted
- Attached to
- SFO FENCE SUPPLIES 2023
- Solicitation number
- 140L6423Q0023
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140L6423Q0023_Amd_0003.pdf | ||
| Amendment_0003_0003.pdf | ||
| Sol_140L6423Q0023_Amd_0002.pdf | ||
| Attachment_3_Revised_Value_Bid_Schedule_0001.xlsx | XLSX spreadsheet | |
| Amendment_0001_0001.pdf | ||
| Sol_140L6423Q0023_Amd_0001.pdf | ||
| Attachment_4_Instructions_to_Offerors.pdf | ||
| Attachment_3_Value_Bid_Schedule.xlsx | XLSX spreadsheet | |
| Attachment_1_Statement_of_Work.pdf | ||
| B01_Combined_Synopsis_and_Solicitation.pdf | ||
| Attachment_2_Clauses_and_Provisions.pdf | ||
| Sol_140L6423Q0023.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUREAU OF LAND MANAGEMENT (BLM)
SFO Fence Supplies
Solicitation 140L6423Q0023
Amendment 0002
The purpose of this amendment is to respond to questions received. All due dates, terms, and conditions remain the same.
Questions and Answers:
1. I have a question on the angle post brace listed on the solicitation, is oilfield pipe acceptable for this bid? Or do you have more detailed information regarding what this bid is calling for exactly regarding angle post?
Oilfield pipe is not an acceptable material. Angle posts and angle braces should be made of non-cylindrical angled steel. The angle post should be 2 ½” x 2 ½” x 7’, with a ½” bolt hole extending 16 ½” from the bottom on the left angle, and a ½” bolt hole extending 13 ½” from the bottom on the right angle. The angle brace should be 2” x 2" x 7’, with a ½” bolt hole extending ½” from the bottom on the left angle, and a ½” bolt hole extending 1” from the bottom on the right angle. Please see the attached pictures and drawings (pages 2-4) for further clarification.
UNITED STATES DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
PECOS DISTRICT OPERATIONS OFFICE
ROSWELL, NM 88201
STEEL STRESS PANEL
REVIEWED BY:
DESIGNED BY:
APPROVED BY:
DRAWN: DSW
DATE:
DRAWING NUMBER:
SCALE: NTS
SHEET _1_ OF _1_FASTENING DETAIL
SEE FASTENING DETAIL
ANGLE SHOULD BE NOTCHED APPROX.
3 12" TO CREATE FASTENING TAB ALONG
FRONT FACE OF VERTICAL ANGLE POST
2" DIA. BOLT WITH NUT AND
WASHERS. IAW CONTRACT SPEC
5'-6" T-POSTS PLACED AT 16'- 6" O.C.
DRIVEN TO A DEPTH OF 1'-6"
TWISTED WIRE FENCE STAYS PLACED AT 16'-6" O.C.
(CENTERED BETWEEN T-POSTS)
BRACE ANCHOR BLOCKS: APPROX. 16" X 16" X 16"
END OF BRACE SHOULD BE CENTERED IN ANCHOR
BLOCK.
WIRE SPACING DIAGRAM
NOTES:
1. PANELS TO BE LOCATED AS PER CONTRACT MAPS. MAXIMUM DISTANCE
BETWEEN PANELS SHALL NOT EXCEED 1320 FEET.
2. PANELS CONSIST OF 3 CONTINUOUS PIECES OF 2- 1/2" X 2- 1/2 X 1/4"
STEEL ANGLE. SOME NOTCHING OF STEEL MEMBERS IS REQUIRED. (SEE FASTENING
DETAIL.
3. ANGLE AND LENGTH OF BRACE MEMBER WILL VARY WITH TOPOGRAPHY AND SITE
CONDITIONS.
BASE FOR VERTICAL STEEL ANGLES SHALL
CONSIST OF A CYLINDRICAL CONCRETE FOOTING
(MIN. 39" DEEP AND 10" IN DIAMETER).
STEEL ANGLE SHALL BE CENTERED IN DIAMETER
AND APPROX. 3" ABOVE BOTTOM OF CYLINDER.
TOP VIEW
ELEVATION VIEW
4. WIRE TO BE ATTACHED ACCORDING TO WIRE SPACING DIAGRAM.
323116-(4)
(4 STRAND BARBED WIRE FENCE)
12" 8" 6"
16"
BLM
BLM
BLM