DIVISION 1 SECTION NV 01009
GENERAL REQUIREMENTS GENERAL INFORMATION AND REQUIREMENTS FOR FENCES
Rev. 1-88
PART 1: GENERAL
1.01 SUMMARY
A. Section Includes: Furnishing wire fence supplies and materials including associated gates and hardware.
B. Location: Supplies will be delivered to Ely, NV. Delivery address defined in section 1.04 of this contract.
C. Base of Operation: Not Applicable.
D. Fencing: The Contractor shall deliver supplies as specified.
E. Equipment: The Contractor shall furnish such tools, equipment and labor to satisfactorily complete this supply delivery in a timely fashion.
1.02 REFERENCES:
A. Referenced Specifications/Standards with Abbreviations and/or Acronyms: Wherever the following acronyms are used in these specifications or on the drawings, they are to be construed the same as the respective expressions represented. Copies of the referenced specifications/standards referred to herein may be procured by the Contractor, from the following:
| ASTM | American Society for Testing and Materials |
| 1916 Race Street | |
| Philadelphia, PA 19103 |
1.03 QUALITY ASSURANCE:
A. Codes and Standards: The work shall comply with codes and standards applicable to each type of work and as listed in the individual sections of these specifications. This Contract incorporates materials, applications, and tests by reference, with the same force and effect as when they were given in full text.
B. Conflict: Where a conflict occurs between reference documents and project specifications, project specifications shall govern.
1.04 DELIVERY, STORAGE, AND HANDLING:
A. Delivery: The Contractor shall protect products to be incorporated into the work from damage while in transit to the site. Products must be delivered in original unopened containers with manufacturer’s name and brand designation and contents legibly indicated. The containers or tags shall bear the referenced specification number, type and class as applicable.
B. Storage: Not Applicable.
C. Handling: The Contractor shall load and unload products in such a manner that protects them from damage until delivery. The products shall be loaded in a manner that would allow them to be unloaded by a forklift upon delivery.
D. Delivery Addresses:
| Ely District Office, Bureau of Land Management |
| Attention: Chris McVicars |
| 702 N. Industrial Way |
| Ely, NV 89301 |
1.05 SEQUENCING AND SCHEDULING:
A. Work Schedule: Delivery of all items would occur within 45 days of contract award. When requested, the Contractor shall submit an updated schedule within 3 calendar days. At a minimum, the delivery dates for all items must be included. Delivery shall occur during business hours Monday-Friday, 7:30am-4:30pm.
PART 2: PRODUCTS
(There are no applicable requirements).
PART 3 EXECUTION
3.01 PROJECT MEETINGS:
A. Pre-Work Conference:
Not Applicable.
B. Progress Meetings:
Not Applicable.
C. Final Inspection:
1. Location: Shall be inspected at the delivery location.
2. Notification: The Contractor shall notify the Contracting Officer’s Representative at least 3 working days before the delivery date so the Government can schedule a final inspection.
3. Attendance: The Contractor or the Contractor’s fully authorized representative shall be present during this inspection.
A. Work Stoppages:
The Government reserves the right to reject delivery when contract specifications are not met. No monetary compensation will be given to the Contractor for delivery rejection.
PART 4: MEASUREMENT AND PAYMENT
4.01 METHOD OF MEASUREMENT:
A. Units: The work described in this section will not be measured for payment.
4.02 BASIS OF PAYMENT:
A. Payment: No direct payment for the work described under this section will be made. Contractors shall include consideration for this item in the bid price for other scheduled items of the Contract.
END OF SECTION
DIVISION 2 SECTION NV 02834
MATERIALS FOR WIRE FENCE AND GATES
Rev. 9-90
PART 1: GENERAL
1.01 WORK SUMMARY:
A. Section Includes: Furnishing wire fence supplies including associated hardware.
B. Related Section: General Information and Requirements for Fences – Section NV 01009
1.02 REFERRENCES:
A. American Society for Testing Materials
| ASTM A121 | Zinc-Coated (Galvanized) Steel Barbed Wire | |
| ASTM A702-81 | Steel Fence Posts and Assemblies, Hot-Wrought | |
| ASTM F1083-87 | Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence Structures | |
| ASTM F1667 Driven Fasteners: Nails, Spikes, and Staples |
PART 2: PRODUCTS
A.01 CONTRACTOR FURNISHED MATERIALS:
A. STEEL FENCE POSTS:
· 7,100 Pieces
· Steel posts shall be 5 feet 6 inches in length, painted green with white or silver tops (unless otherwise stated) “T” bar type, with riveted anchor plate, attached so the top of the plate is not more than 18 inches from the bottom of the post.
· They shall be furnished with clip-type wire fasteners (minimum 4 clips per post) with a zinc coating of at least 0.3 oz. per square foot (punched tabs for fastening wire are not acceptable).
· Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall weigh a minimum of 1.33 lb. per ft. exclusive of the anchor plate, which shall weigh a minimum of 0.67 lb., and shall be a minimum of 18 sq. inches in area.
· Steel fence posts and fasteners shall be in accordance with ASTM A702.
B. STEEL PIPE FOR VERTICAL FENCE STRUCTURES:
· 175 Pieces
· Shall be 2-3/8” outside diameter with a wall thickness of 3/16”
· Shall be made from galvanized steel
· 7’ in length
· Shall be in accordance with ASTM F1083-87
C. STEEL PIPE FOR HORIZONTAL FENCE STRUCTURES:
· 150 Pieces
· Shall be 1-5/8” outside diameter with a wall thickness of 1/8”
· Shall be made from galvanized steel
· 7’ in length
· Shall be in accordance with ASTM F1083-87
D. BARBED WIRE
· 260 Rolls
· Each roll shall be 1,320’ in length
· Shall be two twisted wires of 12 ½ -gauge galvanized wire with 2-point barbs of 14-gauge wire spaced 4 inches apart.
· Wire and barbs shall be zinc-coated steel, with a zinc coating of at least 0.3 oz. per sq. ft. of coated surface area and a minimum breaking strength of 950 lb.-force in accordance with Federal Specification RR-F-221/1 or ASTM A121.
E. BARBLESS WIRE:
· 90 Rolls
· Each roll shall be 1,320’ in length
· Two twisted wire of 12 1/2 –gauge, galvanized wire with no barbs.
· Wire shall be zinc-coated steel wire of at least 0.3 oz. per sq. ft. of coated surface area and a minimum breaking strength of 950 lb.-force in accordance with Federal Specification RR-F-221/1 or ASTM A 121.
F. WIRE FENCE STAYS:
· 7,100 Pieces
· Twisted wire fence stays manufactured from smooth galvanized 9 ½-gauge (minimum) wire at least 30 inches in length and not exceeding 32 inches.
G. FENCING STAPLES:
· 50 pounds
· Staples shall be 9-gauge, bright-finish or galvanized.
· 1” in length.
· Staples shall be barbed
· Staples shall be in accordance to ASTM F1667
H. CARRIAGE BOLTS AND NUTS:
· 250 Pieces
· Shall be 3/8” x 1-½”
· Shall be composed of galvanized steel
· Shall be compatible with items “I”, “J” and “L”
I. 2-3/8’ BRACE CLAMPS:
· 350 Pieces
· Shall be ¾” x 2-3/8” diameter (to fit item “B” and be fastened by item “H”)
· Shall be made from 12-guage galvanized steel
J. 3” BRACE CLAMPS
· 175 Pieces
· Shall be ¾” x 3” diameter (to fit 3” pipe and be fastened by item “H”)
· Shall be made from 12-guage galvanized steel
K. FENCE POST CAPS
· 175 Pieces
· Shall be made from aluminum
· Shall have 2-3/8” inside diameter (to fit over item “B” – 2-3/8” steel pipe) and be dome shaped
L. RAIL END CAPS
· 260 Pieces
· Shall have an inside diameter of 1-5/8” (to fit on end of item “C”)
· Shall be made from galvanized steel
· Shall be compatible with items “I” and “H”
· Steel pipe shall be in accordance with ASTM F1083-87
M. WOOD FENCE GATE END POLES
· 75 Pieces
· Shall be 4’ in length and 4” in diameter
· Treatment with preservative is not required
· Shall be made from Ponderosa Pine or Lodgepole Pine
N. WOOD GATE STAYS:
· 100 Pieces
· Treatment with preservative is not required
· Stays shall have a length of 4’0”.
· Stays shall be made from either Ponderosa Pine or Lodgepole Pine
· Wood gate stays for wire gates shall be sound and straight pieces, 1-½ inches minimum and 2-½ inches maximum diameter.
PART 3: EXECUTION
3.00 SPECIFIC ITEMS TO BE DELIVERED
A. Specific Items to be shipped to the location listed in Section 1.04 of this contract.
END OF SECTION