Attachment_0005__-_Revised_Constructions_Drawings_0004.pdf
PDF 342 KB Posted
- Attached to
- CLIFFSIDE LAB ROOF REPLACEMENT Federal contract opportunity
- Solicitation number
- 140L0621Q0071
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L0621Q0071_Amd_0004.pdf | ||
| Attachment_0006_-_Pricing_Worksheet_0004.xlsx | XLSX spreadsheet | |
| Sol_140L0621Q0071_Amd_0003.pdf | ||
| Attachment_0004_-_Pricing_Worksheet_0002.pdf | ||
| Sol_140L0621Q0071_Amd_0002.pdf | ||
| Sol_140L0621Q0071_Amd_0001.pdf | ||
| Attachment_1_Statement_of_Work.pdf | ||
| Attachment_3_DOL_Wage_Determiniation.pdf | ||
| Sol_140L0621Q0071.pdf | ||
| Attachment_2_Drawings_and_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCALITY MAP
PROJECT SITE
OWNER
BUREAU OF LAND MANAGEMENT
AMARILLO FIELD OFFICE
801 South Fillmore, Suite 500 Amarillo, TX 79101
CONTRACTING OFFICER REPRESENTATIVE (COR)
Alex Chau
(806) 356 - 1050
DESIGN TEAM
ARCHITECT:
CHAMBERLIN ARCHITECTS
437 Main St.
Grand Junction, CO 81501
(970) 242-6804
VICINITY MAP
LA
B
B U
IL
D
IN
G
R O O F
R E P A
IR
A M A R
IL
LO
F
IE
LD
O F F
IC
E
A M A R
IL
LO
TX
L1 P D
C
LI
F F S
ID
E
H E
LI
U M
E N R
IC
H M E N T U N
IT
B U R E A U
O F
LA
N D
M A N A G E M E N T
U N
IT
E D
S
TA
TE
S
D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H K 'D
B Y
D R A W N
B Y
P R O
JE
C T N O
D E S
IG
N E D
B Y
D E S
IG
N
O F F
IC
E
A P P R O V E D
B Y
D A
TE
D E S C R
IP
TI
O N
M A R K
A P P R O V E D
D A
TE
SHEET OF
B U R E A U
O F
LA
N D
M A N A G E M E N T
U .S D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H A M B E R
LI
N
A R C H
IT
E C
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
G001 w d d g w d
DRAWING LIST
DRAWING
NO.
SHEET
NO. SHEET NAME
GENERAL
1 G001 COVER SHEET
ARCHITECTURAL
2 A001 NOTES, SYMBOLS, ABBREVIATIONS
3 A141 ROOF PLAN
4 A641 ROOF DETAILS
CHEU LAB BUILDING ROOF REPAIR
AMARILLO, TX
11/24/2015
REVISION
ELEVATION
COLUMN GRID LOCATION
DOOR NUMBER
WINDOW TYPE
CENTER LINE
LINE OF WALL ABOVE OR HIDDEN
LINE
BREAK LINE
MATCH LINE
ROOM NAME
ROOM NUMBER
INTERIOR WALL ELEVATION
REFERENCE DRAWING
REFERENCED SECTION NUMBER
SHEET NUMBER
BASIC WALL TYPE
WALL TYPE AND PROPERTIES, SEE
"WALL DESIGNATION KEY" BELOW
REFERENCED DETAIL NUMBER
SHEET NUMBER
A101
A
101A
Room
A101
TYP
A101
TYP
ANGLE
DIAMETER
PERPENDICULAR
PLATE
PLUS OR MINUS
FLOOR DRAIN
FIRE EXTINGUISHERFE
FD
100' 0"
TOP OF WALL
SB2 XD
AL HM
1. COMPLY WITH ALL MANUFACTURERS
RECOMMENDATIONS AND INDUSTRY
STANDARDS RELEVANT TO THE
WORK HEREIN.
2. ALL DIMENSIONS ARE FROM FACE
OF FINISH UNO.
3. ALL ALIGNMENTS ARE FACE OF
FINISH UNO.
4. FIELD VERIFY ALL DIMENSIONS AND
ROUGH OPENINGS PRIOR TO
FABRICATION AND/OR INSTALLATION.
ABV above ACC accessories AFF above finished floor ALT alternate AL aluminum APC acoustical panel ceiling ARCH architect (ural) ASPH asphalt A/C air conditioning
BCS baby changing station BD board BLDG building BLKG blocking BO bottom of BRG bearing
CBU cemetitious backer unit CG corner guard CJ control joint CLG ceiling CLR clear (ance) CMU concrete masonry unit CNRG corner guard COL column CONC concrete CONT continuous or continue CORR corridor CPT carpet (ed) CSMT casement CT ceramic tile CTR center CWOG center wall on grid
DBL double DEMO demolish / demolition DF drinking fountain DIM dimension (s) DIR direction DISP dispenser DN down DR door DS downspout DTL detail DWG drawing DWR drawer
E east EA each EC evaporative cooler
EG etched glass/glazing EIFS exterior insul finish sys EJ expansion joint EL elevation ELEC electric (al) EM emergency EWC electric water cooler EWG end wall corner guard EQ equal EXG existing EXH exhaust EXP exposed EXT exterior
FBO furnished by owner FD floor drain FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FEP finished end panel FFE finished floor elevation FIN finish FLG flashing FLR floor (ing) FLUR fluorescent FO face of FRMG framing FRP fiber reinforced plastic FT foot (feet) FTG footing FV field verify
GA gage, gauge GAL gallon GALV galvanized GB grab bar GC general contractor GL glass, glazing GWB gypsum wallboard GYP gypsum
HAS headed anchor stud HB hose bibb HCP handicap (ed) HDR header HDW hardware HM hollow metal HOR horizontal HSS hollow structural sections
HT height HVAC heating /vent /air cond HWD hardwood
INCL include (d) (ing) INSUL insulate (d) (ing) INT interior INV invert
JST joist JT joint
L length, angle LAM laminate (d) LAV lavatory LB pound LF lineal foot LG laminated glass, glazing LIN linoleum LT light
MA match MAS masonry MATL material MAX maximum MB marker board MECH mechanic (al) MFR manufacture (r) (d) MH manhole MIN minimum MISC miscellaneous MLD molding, moulding MMB membrane MO masonry opening MT mount (ed) (ing) MTL metal
N north N/A not applicable NIC not in contract NOM nominal NTS not to scale NECY necessary
OC on center (s) OD outside diameter OFD overflow drain OH overhead OPG opening
OPH opposite hand OPP opposite OSB oriented strand board OTS open to structure
PB particle board PERF perforate PERIM perimeter PLAM plastic laminate PLT plate PNL panel PNT paint (ed) PR pair PROJ projector, projection PSF pounds per square foot PSI pounds per square inch PT pressure treated PTD paper towel dispenser PTN partition PVC polyvinyl cholride PVMT pavement PWD plywood
QT quarry tile
R riser, radius RB rubber base REC recycling RCMD recommend (ed) (ations) RE reference REF refrigerator REIN reinforce (d) (ing) REQ required REV revision (s), revised RD roof drain RFG roofing RH robe hook RM room RO rough opening ROW right of way RR restroom RTU roof top unit RUB rubber
S south SAG susp acoustic grid SC shower curtain rod & hooks SCH schedule SD soap dispenser
SHT sheet SHTG sheathing SIM similar SND sanitary napkin dispenser SNV sanitary napkin vendor SPEC specification SPKR speaker SQ square SST stainless steel STD standard STL steel STOR storage STR structural SUSP suspended
T tread TB towel bar TEL telephone T.O. top of TOC top of concrete TOS top of steel TOW top of wall TPD toilet paper dispenser TS tube steel TYP typical T&G tongue and groove
UNO unless noted otherwise
VB vapor barrier VCT vinyl composition tile VERT vertical VIF verify in field VM vending machine VNL vinyl sheet VTR vent through roof
W west, wide, width W/ with WB wood base WC watercloset WD wood WDW window WF wide flange WG wire glass W/O without WP waterproof (ing) WR waste receptacle WRB weather resistive barrier WWM welded wire mesh
LA
B
B U
IL
D
IN
G
R O O F
R E P A
IR
A M A R
IL
LO
F
IE
LD
O F F
IC
E
A M A R
IL
LO
TX
L1 P D
C
LI
F F S
ID
E
H E
LI
U M
E N R
IC
H M E N T U N
IT
B U R E A U
O F
LA
N D
M A N A G E M E N T
U N
IT
E D
S
TA
TE
S
D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H K 'D
B Y
D R A W N
B Y
P R O
JE
C T N O
D E S
IG
N E D
B Y
D E S
IG
N
O F F
IC
E
A P P R O V E D
B Y
D A
TE
D E S C R
IP
TI
O N
M A R K
A P P R O V E D
D A
TE
SHEET OF
B U R E A U
O F
LA
N D
M A N A G E M E N T
U .S D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H A M B E R
LI
N
A R C H
IT
E C
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
A001 w d d g w d
SYMBOLS GENERAL NOTESARCHITECTURAL ABBREVIATIONS
A141
EXG VTR
EXG VTR
EXG VTR
EXISTING FLUE VENTS
A641
A641
EXISTING GUTTER
TO REMAIN
.. SLOPE 1":12"SLOPE 4":12".SLOPE 4":12"
31' - 0" +/-
32' - 6" +/-
NO WORK ON ENTRY ROOF BELOW
REMOVE RIDGE CAP TO REPLACE
CLOSURE STRIP AND REPLACE
A641
SIM.
8"
EXPOSED-FASTENER, LAP-SEAM, METAL ROOF PANELS
BID ALTERNATE NO. 1: : INSPECT ROOF BATT INSULATION, AND REPLACE WET,
MOLDY OR DAMAGED INSULATION WITH NEW OF SAME TYPE AND R-VALUE.
UPPER ROOF LOWER ROOF
0"
0"
LA
B
B U
IL
D
IN
G
R O O F
R E P A
IR
A M A R
IL
LO
F
IE
LD
O F F
IC
E
A M A R
IL
LO
TX
L1 P D
C
LI
F F S
ID
E
H E
LI
U M
E N R
IC
H M E N T U N
IT
B U R E A U
O F
LA
N D
M A N A G E M E N T
U N
IT
E D
S
TA
TE
S
D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H K 'D
B Y
D R A W N
B Y
P R O
JE
C T N O
D E S
IG
N E D
B Y
D E S
IG
N
O F F
IC
E
A P P R O V E D
B Y
D A
TE
D E S C R
IP
TI
O N
M A R K
A P P R O V E D
D A
TE
SHEET OF
B U R E A U
O F
LA
N D
M A N A G E M E N T
U .S D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H A M B E R
LI
N
A R C H
IT
E C
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
A141 w d d g w d
0' 2'
4'0' 2'
4' A141
ROOF PLAN1
0' 2'
4'0' 2'
4' A141
WEST ELEVATION2
NEW CLOSED-CELL
LAMINATED POLYETHYLENE
CLOSURE STRIP
NEW 3/16" x 7/8" TAPE MASTIC
CONT. TOP AND BOTTOM OF
CLOSURE PLUG TYPICAL
REINSTALL EXISTING
EAVE FASCIA
NEW 1/4-14 x 1 1/8" S.S. ROOF
STITCH FASTENER WITH EPDM
OR PVC SEALING WASHERS
NEW 1/4-14 x 7/8" WALL STITCH
FASTENER @ 1' - 0" O.C WITH EPDM
OR PVC SEALING WASHERS
NEW CLOSED-CELL
LAMINATED POLYETHYLENE
CLOSURE STRIP
NEW 3/16" x 7/8" TAPE MASTIC
CONT. TOP AND BOTTOM OF
CLOSURE PLUG TYPICAL
REMOVE EXISTING RAKE
FLASHING AS NECESSARY TO
INSTALL NEW CLOSURE STRIP
AND REINSTALL
EXISTING ROOF PANEL
EXISTING VINYL FACED
INSULATION TO REMAIN
NEW CLOSED-CELL
LAMINATED POLYETHYLENE
CLOSURE STRIP
NEW 1/4-14 x 1 1/8" S.S. ROOF
STITCH FASTENER WITH EPDM
OR PVC SEALING WASHERS
EXISTING ROOF PANEL
REMOVE AS NECESSARY TO REMOVE
AND REINSTALL CLOSURE STRIP
EXISTING VINYL FACED INSULATION TO
REMAIN
REMOVE EXISTING WALL PANEL AS
NECESSARY TO INSTALL NEW CLOSURE
STRIPS AND REINSTALL
EXISTING MTL
BUILDING FRAME
EXISTING WALL INSULATION
GENERAL: REMOVE EXISTING ROOF PANELS AND FLASHING AS
INDICATED, REMOVE EXG FOAM AND CLEAN EXPOSED METAL,
INSTALL NEW CLOSURE STRIPS AND REINSTALL.
EXISTING MTL
BUILDING FRAME
EXISTING VINYL FACED
INSULATION TO REMAIN
ALTERNATE # 1: REMOVE AND
REPLACE
NEW CLOSED-CELL
LAMINATED POLYETHYLENE
CLOSURE STRIP
NEW 1/4-14 x 1 1/8" S.S. ROOF
STITCH FASTENER WITH EPDM
OR PVC SEALING WASHERS
EXISTING ROOF PANEL
NEW 3/16" x 7/8" TAPE MASTIC
CONT. TOP AND BOTTOM OF
CLOSURE PLUG TYPICAL
REMOVE EXISTING ROOF RIDGE CAP, REMOVE EXG FOAM AND
CLEAN EXPOSED METAL, INSTALL NEW CLOSURE STRIPS AND
REINSTALL CAP
NEW CLOSURE STRIP, TAPE
MASTIC AND FASTENERS
LA
B
B U
IL
D
IN
G
R O O F
R E P A
IR
A M A R
IL
LO
F
IE
LD
O F F
IC
E
A M A R
IL
LO
TX
L1 P D
C
LI
F F S
ID
E
H E
LI
U M
E N R
IC
H M E N T U N
IT
B U R E A U
O F
LA
N D
M A N A G E M E N T
U N
IT
E D
S
TA
TE
S
D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H K 'D
B Y
D R A W N
B Y
P R O
JE
C T N O
D E S
IG
N E D
B Y
D E S
IG
N
O F F
IC
E
A P P R O V E D
B Y
D A
TE
D E S C R
IP
TI
O N
M A R K
A P P R O V E D
D A
TE
SHEET OF
B U R E A U
O F
LA
N D
M A N A G E M E N T
U .S D E P A R
TM
E N T O F
TH
E
IN
TE
R
IO
R
C H A M B E R
LI
N
A R C H
IT
E C
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
C O N S
TR
U C
TI
O N
D O C U M E N
TS
F
IN
A L C O N S
TR
U C
TI
O N
D O C U M E N
TS
A641 w d d g w d
0' 3"
6"0' 3"
6" A641
ROOF EAVE DETAIL1
0' 3"
6"0' 3"
6" A641
ROOF RIDGE DETAIL2
File details come from the government source that posted it. Updated .