This is an amendment to a federal contract solicitation that corrects a reporting level discrepancy for a chemical specification. Amendment 2 addresses an error in Attachment A-Final Questions and Answers, which contained an incorrect report level for the 7.5-7.7N Ultrex Nitric Acid constituent specification. The incorrect report level listed in the prior attachment was 1.0 µg/L, whereas the correct report level established in Amendment 1 is 0.03 µg/L. Both values relate to metal contamination testing using inductively coupled plasma-mass spectrometry (USGS OF 92-634 method) for filtered water samples.

The corrected specification applies to 2.0 mL of 7.5-7.7N Ultrex grade nitric acid solution (JT Baker) in a 4.5 mL polypropylene copolymer screw cap vial under Section D 1). The requirement specifies that contamination levels of metal constituents shall be less than 0.03 µg/L when the vial contents are prepared to the equivalent of 1 vial volume added to 250 mL of deionized water. All other terms and conditions of the solicitation remain unchanged.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3A-The Purpose of this Amendment 2

A. The purpose of this amendment is to correct a discrepancy in Attachment A-Final Questions and Answers from the revised report level table in Amendment 1.

B. Attachment A-Final Questions and Answers included the incorrect report level in the table for the 7.5-7.7N Ultrex Nitric Acid:

Constituents Report

Level

Unit Method Description Method

Number

W 1.0 µg/L Metals, filtered water, Inductively coupled plasma-mass spectrometry

USGS OF 92-

Attachment 3-The Purpose of this Amendment 1 included the correct report level in the table for the 7.5-7.7N Ultrex Nitric Acid:

Constituent Report

Unit Method Description Method Number

W 0.03 µg/L Metals, filtered water, Inductively coupled plasma-mass spectrometry

USGS OF 92-634

Therefore, the report level in the table below is correct under Section D 1) 2.0 mL, 7.5-7.7N

Ultrex grade nitric acid solution (JT Baker), in a 4.5 mL polypropylene (PP) copolymer screw cap vial (polyvials).

d) Contamination levels of the following metal constituents shall be less than the report levels described below when prepared to the equivalent of 1 vial volume added to 250 mL of deionized water.

Constituent Report

Unit Method Description Method Number

W 0.03 µg/L Metals, filtered water, Inductively coupled plasma-mass spectrometry

USGS OF 92-634

ALL OTHER TERMS AND CONDITIONS ARE UNCHANGED