Boiler_Specs.pdf
PDF 505 KB Posted
- Attached to
- Replacement Boiler Federal contract opportunity
- Solicitation number
- 140G0125Q0082
About this file
This file shows technical specifications for two boilers - an existing Fulton Gas Fired Pulse Combustion Boiler that needs replacement and a proposed replacement LAARS Magnatherm FT gas-fired hot water boiler (Model CPH3000HHD13X). The LAARS replacement boiler specifications include: 3,000,000 BTU/hr input, 2,805,000 BTU/hr output, 95.9% combustion efficiency, natural gas fuel, 210°F maximum water temperature, and clearance requirements of 1 inch from top, 4 inches from sides, and 18-24 inches front/rear. It is certified for installation on combustible flooring and rated as a low pressure Category II or IV boiler.
The existing Fulton boiler being replaced is a direct vent model for non-combustible floor installation only, with electrical ratings of 120V/60Hz and less than 12 amps. It operates on either natural gas or propane with a maximum gas supply pressure of 14 inches W.C. The replacement project is being managed by the USGS Wetland and Aquatic Research Center in Lafayette, LA as a small business set-aside under NAICS 332410, with quotes due March 19, 2025. Vendors must be SAM registered to be considered for award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140G0125Q0082_Amd_0002.pdf | ||
| Boiler_Room_Pictures_0001.pdf | ||
| Sol_140G0125Q0082_Amd_0001.pdf | ||
| Sol_140G0125Q0082.pdf | ||
| Wage_Determination_2015-5183.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
°"lanecl.M•nufact...., -c- ■, (Coe;v, PalN1411H ■t C.rttM P•r)
MAONATHIRM FT
0.. PINd Hot Water Bolle, iuo.s• Heaf'ul9 Sya,.,,_ C°""PO"y lllec ... 1111, NN u.&J.. • ll11l11111p, -.c-.
I'- l!ITMl!ll IN- OR OUTDOOR INSTALLATION LOW Pllll!UUltl! ■otLl!II, CATl!OOIIY It O11 IV
-· Z21.1S.Z017-2017.CU ..... 2017 CIIN. YH72.2C
FOR INITALU.TION ON COMSUST1&1.1! f"LOOltlNG (lnstaH., Huie •◄nl..,, "" plwh.., c--..tMlile) Mlftimum dHran,:ea fNMn �-- 141rfac ..
f,,,.�� ...... •ue---•
A'\Al •�'1' �Qt:.Auow.J011,ANlaiq,e1,,__,.•"-•• 1•--
- ite �•� (.1t,fUCJlri"IOllfV li■i;;;;;i-;;;...,;;;;-;..,;;iDai;ie.;-.,70...!>.itiio.o'FFiioon;;;..-,.;;;;;---,,;;-.._;;;;;;;,,ii1,i;"i20iizi11-J Top' g,...,..
C ... ranc.• From 1 ...... / •� Sen,fce ,._., 1 ..... as.A-.
...... 0$ ; 111 ModMeNo CPNNHl:UID1JOC Lefta...tc�.-... •1a.11ou-.. 1111,ft:J.lA-, -...eaw.,eo..droll ........... _ &ln.11u.-
......._. 17... Proat/Avaftt 11-....r.a,_. MlM ..... -•
-. N 7 c t llo O.S.,,. W2117 l"ij,i;:i;.;;;i;jji;ij;;;j';.;;;;;-----;;;;:::-=---;;:;;;;:;--7---1 ,.,...,_ 11 lll.al'M.... Ml-.i-.•-•
Oiea�1111.....,powprz
..,.., ___ ...,_...,_, •• �7
Replacement must be compatible with existing LAARS Model
This Boller Is a Direct vesll:,:, tor Installations on Non-Co�=le Floors Only Fulton Gas Rred Pulse Combustion BoilerType of Gas: O Natural □ f1r1P1M
Boller Model No.
Boller National Board No.
Year Min, BTU Input/Hr. Min. BTU Output/Hr.
Max. BTU Input/Hr.') n "' Max. BTU Output/Ht Design Pressure PSI l BOC Pounds/Hr.
��::.:.:.:.:.:.:�:-:--:--:-:-;::� Inches W.C. Mimimum Relief Valve Cap.aclty:
�anifold Gas Pressure:
ply Pressurt· 14 llcllll W,C. lidlllm GasSup l...._ Gas Sup;l)Pl II ,.,.,,.,u, II_,..,, •
c. au.._.u.
•· blellt: 07lncbeSW, .. D. ll!!IIP' 120V/60H1/IID
:� ,_. .. 5teu1.HotWallr ���i:�-.)()1 • CSA
..... Pr9lil1re Steaill Boller0 H,.., lleqUllemBllb 3-89
A.GA .
� 'JbnlUgll Wldcb -
Old Boiler that needs to be replaced
File details come from the government source that posted it. Updated .