Text version
Salient Characteristics IDIQ REQUEST
The Hydrologic Instrumentation Facility (HIF) needs to procure smart electronic communication devices that are used to interface with YSI 6-series brand of water quality sondes/sensors. The devices are needed to re-stock the HIF warehouse. The units are used as part of a water quality monitoring system to measure water quality parameters at rivers and streams all over the country.
Y-Hub Interterface
Requirements: The Y-Hub shall:
• Interface to the YSI 6-Series sondes and 650 handheld display unit
• Include a Bluetooth interface and module for attaching to a 650 display
• Include an interface to allow connection to datalogger or DCP for power and SDI-12 communication
• Provide uninterrupted Bluetooth connectivity to the 6-series sondes without the need to pull the sonde out of the water and/or change cables
• Include LEDs to show the source of any power failure for troubleshooting purposes
• Provide regulated power to the 6-series sonde
• Weigh no more than 2 lbs
• Include an IP rating of at least IP67
• Operate over a temperature range of at least -20 to 60 degrees C
• Include an SDI-12 flying lead adapter cable