B09_-_Solicitation_Amendment_00001_(Asbestos_Survey)_0001.pdf
PDF 5 MB Posted
- Attached to
- CO SAN LUIS VALLEY NWR COMPLEX ABATEMENT Federal contract opportunity
- Solicitation number
- 140FGA25Q0002
About this file
This file contains three asbestos survey reports conducted by Environmental Testing Laboratories for buildings at the Alamosa National Wildlife Refuge, prepared for US Fish and Wildlife Service. The reports detail asbestos inspections performed between October 9-17, 2023 at three different buildings: a double-wide mobile home (QTRS #1) and a single-wide mobile home (QTRS #5).
The surveys identified multiple asbestos-containing materials (ACM) across the buildings. In QTRS #1 Mobile Home Double Wide D, four types of linoleum containing 3-4% chrysotile asbestos were found in various rooms. In QTRS #5 Mobile Home Single Wide D, grey stone linoleum containing 15% chrysotile asbestos was found near the entry door. The reports also documented other hazardous materials including refrigerators, stoves, ovens, furnaces, hot water heaters, mercury thermostats, and smoke detectors that require special handling and disposal. The inspections were conducted by certified Colorado asbestos inspectors Alan Hill and Robert Perry, and the reports include detailed sampling data, laboratory analysis results, and photographic documentation of the surveyed areas.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140FGA25Q0002_Amd_0001.pdf | ||
| B08_-_Solicitation_(Attachment_-_Submittals).pdf | ||
| Sol_140FGA25Q0002.pdf | ||
| B08_-_Solicitation_(Attachment_-_Wage_Determination_Davis_Bacon).pdf | ||
| B08_-_Combined_Synopsis_Solicitation.pdf | ||
| B08_-_Solicitation_(Attachment_-_SOW).pdf | ||
| B08_-_Solicitation_Form_SF1442.pdf | ||
| B08_-_Solicitation_(Attachment_-_Price_Schedule).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey Report
FOR THE PROPERTY AT:
Alamosa NWR QTRS 1, Mobile Home Double Wide D
ETC Job #: 261660
Prepared For:
US Fish and Wildlife 5275 Leesburg Pike
Falls Church, VA 22041 612-713-5214
Date of Inspection: 10/09/2023-10/13/2023 & 10/16/2023-10/17/2023
Date of Report: 11/03/2023
Asbestos Surveyors:
Alan Hill & Robert Perry
Colorado Asbestos Inspector License #: 29247 & 29244 Colorado Asbestos Inspector License Expiration Date: 09/24/2024
Report Prepared and Submitted By:
Megan Kuziak
38900 West Huron River Drive
Romulus, MI 48174 734-955-6600 www.2etc.com
ETC Job #: 261660 Page 2 of 27
TABLE OF CONTENTS
ASBESTOS SURVEY REPORT
PURPOSE OF THIS INVESTIGATION
KEY DEFINITIONS
EXECUTIVE SUMMARY
MATERIALS TABLE
MATERIALS SAMPLED AND ASBESTOS CONTENT
OTHER HAZARDOUS MATERIALS
INSPECTOR CERTIFICATION
APPENDICES
APPENDIX A – MAPS
APPENDIX B – PHOTOS
APPENDIX C – EDUCATION, TESTING, RESOURCES & LAWS
APPENDIX D – COLORADO ASBESTOS CERTIFICATION
APPENDIX E – LABORATORIES USED & ORIGINAL LABORATORY ANALYSIS REPORTS
ETC Job #: 261660 Page 3 of 27
Purpose of this investigation The purpose of this inspection was to determine the presence and quantity of ACM’s.
KEY DEFINITIONS
ACM Asbestos containing material. ACM’s fall into 1 of 3 types. See Appendix C-1
Friable Can be crumbled, pulverized, or reduced to powder by the pressure of an ordinary human hand.
Non-Friable Cannot be pulverized under hand pressure.
Potentially Can become friable if disturbed.
Friable
Category Refers to the two (2) types of Non-Friable ACM’s. See Appendix C-1
Hazardous Non-asbestos materials that may be hazardous, and may require special handling Materials and disposal requirements.
Room The room testing occurred. Rooms are identified by a number because room usage may change (i.e., a bedroom may become an office). Some rooms may be labeled as functional spaces (FS).
Inaccessible These are locations around the property that could not be examined because the Area’s investigator could not gain access to them. These include areas that are unsafe to enter, locked rooms, areas with too much debris/clutter, etc.
Quantity Materials are usually quantified in square feet (SF), cubic feet (CF), linear feet (LF), cubic yards (CY), or units.
EPA Environmental Protection Agency
OSHA Occupational Safety and Health Administration
ETC Job #: 261660 Page 4 of 27
Executive Summary
After a thorough investigation of the premises was conducted, and samples were collected and analyzed, the following materials were found to contain asbestos in a concentration >1%, in accordance with EPA, OSHA, and other federal, state, and local standards (Please refer to “Interpretation of Inspection Results” in section C-2):
Linoleum, Brown/Red (mosaic) – FS 11
Linoleum, Red (flower pattern) – FS 10
Linoleum, Brown – FS 12
Linoleum, Orange/Brown – FS 2
In addition, other hazardous materials were found and are located in:
Refrigerator – FS 2
Stove – FS 2
Washer – FS 2
Furnace – FS 6
Hot Water Heater – FS 9, 15
Smoke Detectors – FS 4-8
Underground Storage Tank – FS 9
Note: If renovations are not being done in a specific room that was found to have positive ACMs you do not need to remove that material as long as it is intact.
Before renovation or demolition activities can begin, and depending on the ACM found and the condition that it is in, it may be necessary that friable or potentially friable ACMs be removed.
ETC Job #: 261660 Page 5 of 27
Materials Table
MATERIALS SAMPLED AND ASBESTOS CONTENT
TABLE 1: ASBESTOS CONTENT RESULTS
SA
M
P
LE
O
F
SA
M
PL
ES
C O
LL
EC
TE
D
MATERIAL DESCRIPTION FRIABLE (F) OR NON-
FRIABLE (NF)
CATERGORY
1 OR 2
LOCATION
(REFER TO MAPS IN
APPENDIX A)
QUANTITY ASBESTOS
1 3 Drywall, Tape & Mud, White F FS 13-14 1240 SF No
2 3 Linoleum, Brown/Red (mosaic) NF – Cat 1 FS 11 35 SF Yes
3 3 Linoleum, Red (flower pattern) NF – Cat 1 FS 10 26 SF Yes
4 3 Linoleum, Beige (flower pattern) NF – Cat 1 FS 15 118 SF No
5 3 Linoleum, Brown NF – Cat 1 FS 12 56 SF Yes
6 3 Ceramic Tile, Grout & Mortar, Brown NF – Cat 2 FS 4 25 SF No
7 3 Cove Base, Brown NF – Cat 2 FS 2, 12 15 SF No
8 3 Cove Base Mastic, Yellow NF – Cat 2 FS 2, 12 15 SF No
9 3 Linoleum, Orange/Brown NF – Cat 1 FS 2 93 SF Yes
10 3 Paneling, White NF – Cat 2 FS 1-12 1506 SF No
11 3 Cinderblock Mortar, Grey NF – Cat 2 Exterior, All Sides 416 SF No
12 3 Fiberboard, White/Tan F Exterior, All Sides 1310 SF No
13 3 Concrete, Grey NF – Cat 2 Exterior Sidewalk, FS 13-14 1018 SF No
14 3 Caulk, Clear (exterior) NF – Cat 2 Exterior, Addition Windows 58 LF No
15 3 Caulk, Brown (exterior) NF – Cat 2 Exterior, Addition Trim 954 LF No
16 3 Asphalt Shingles, Black NF – Cat 1 Exterior Roof 2160 SF No
17 3 Ice Shield, Black NF – Cat 2 Exterior Roof 2160 SF No Bolded materials are those that were found to contain asbestos at a concentration >1%. Please refer to “Interpretation of Inspection Results” in section C-2.
Quantities that are listed are estimates only; in general, listed quantities represent only what was visible during testing. It is likely that where ACM has been identified throughout specific floors, similar materials and quantities exist on other like floors. It is the contractors’/client’s responsibility to verify all amounts of asbestos identified during any bid process, or during future renovation and/or demolition activities. Materials that are identical in both relative location and physical description to already tested materials listed in this report should always be assumed to be ACM.
ETC Job #: 261660 Page 6 of 27
OTHER HAZARDOUS MATERIALS
TABLE 2: OTHER HAZARDOUS MATERIALS
PL
E
# MATERIAL DESCRIPTION QUANTITY LOCATION
1 Refrigerator 1 FS 2
2 Stove 1 FS 2
3 Washer 1 FS 2
4 Furnace 1 FS 6
5 Hot Water Heater 2 FS 9, 15
6 Smoke Detectors 5 FS 4-8
7 Underground Storage Tank 1 FS 9 Materials found in this chart are above the household quantity limitations. Refer to “Other Hazardous Materials and Vermiculite” in section C-3.
Quantities that are listed are estimates only; in general, listed quantities represent only what was visible during testing. It is likely that where ACM has been identified throughout specific floors, similar materials and quantities exist on other like floors. It is the contractors’/client’s responsibility to verify all amounts of asbestos identified during any bid process, or during future renovation and/or demolition activities. Materials that are identical in both relative location and physical description to already tested materials listed in this report should always be assumed to be ACM.
ETC Job #: 261660 Page 7 of 27
Inspector Certification
The information contained in this report is a true and accurate representation of the conditions and activities at this property at the time of this investigation, based on the professional judgment of the person(s) who conducted and reported this asbestos inspection.
All inspection work was completed by the Colorado certified asbestos inspector(s) listed below.
Inspector E-Mail address: Alan.Hill@2etc.com & Robert.Perry@2etc.com
ETC Job #: 261660 Page 8 of 27
Appendices
APPENDIX A – MAPS
Floor Plans
INTERIOR FIRST FLOOR
Please Note: This is a rough floor plan only. All items, (doorways, windows, etc.) may not be included in this illustration. Also, room and component sizes are not drawn to scale.
ETC Job #: 261660 Page 9 of 27
APPENDIX B – PHOTOS
North South
East
West
ETC Job #: 261660 Page 10 of 27
FS 1 FS 2
FS 3
FS 4
ETC Job #: 261660 Page 11 of 27
FS 5 FS 6
FS 7
FS 8
ETC Job #: 261660 Page 12 of 27
FS 9 FS 10
FS 11
FS 12
ETC Job #: 261660 Page 13 of 27
FS 13 FS 14
FS 15
Positive - Sample Material 2
ETC Job #: 261660 Page 14 of 27
Positive - Sample Material 3 Positive - Sample Material 5
Positive - Sample Material 9 Hazard – Refrigerator
ETC Job #: 261660 Page 15 of 27
Hazard – Furnace Hazard – Hot Water Heater
Hazard – Hot Water Heater (2) Hazard – Smoke Detector
ETC Job #: 261660 Page 16 of 27
Hazard – Smoke Detector Hazard – Smoke Detector
Hazard – Smoke Detector Hazard – Smoke Detector
ETC Job #: 261660 Page 17 of 27
Hazard – Storage Tank Hazard – Stove
Hazard – Washer
ETC Job #: 261660 Page 18 of 27
APPENDIX C – EDUCATION, TESTING, RESOURCES & LAWS
C-1: Asbestos Education
ASBESTOS
Asbestos is a generic term encompassing various fibrous mineral silicates from 2 groups:
Serpentine – “curly fibers” and layered structure o Chrysotile (hydrated magnesium silicate) – about 95% of asbestos in US buildings
Amphibole – “needle-like” structure o Amosite (iron magnesium silicate) – 2nd most commonly used asbestos o Crocidolite (sodium-iron silicate) o Tremolite (calcium-magnesium silicate) – potential contaminate in vermiculite o Anthophyllite (another iron-magnesium silicate) o Actinolite (calcium-magnesium-iron silicate)
CATEGORIES OF ASBESTOS CONTAINING MATERIALS
The EPA identifies three (3) categories of ACM used in buildings:
Surface Materials – ACM sprayed or troweled on surfaces (i.e. walls, ceilings, etc.) for acoustical, decorative, or fireproofing purposes (i.e. plaster and fireproofing insulation).
Thermal System Insulation (TSI) – Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, ducts, HVAC systems, etc. This includes pipe lagging, pipe wrap, block, batt, cements, “muds”, ropes, gaskets, etc.
Miscellaneous Materials – Other, largely non-friable products, that include floor tile, ceiling tile, roofing felt, wall board, outdoor siding, etc.
CHARACTERISTICS OF ASBESTOS CONTAINING MATERIALS
ACMs are characterized in one of two ways. They are either:
Friable – when dry, can be crumbled, pulverized, or reduced to powder by the pressure of an ordinary human hand.
Non-Friable – cannot be pulverized under hand pressure.
o Category I – includes asbestos packings, gaskets, resilient floor covering, and asphalt roofing products.
o Category II – any non-friable ACM not included in Category I such as mastic, cementitious materials, and ceiling tiles.
ASBESTOS EXPOSURE
Airborne asbestos contamination in buildings is a significant environmental problem. It has been determined and documented that inhalation of significant quantities of airborne asbestos fibers over an extended period of time can have serious health effects.
ETC Job #: 261660 Page 19 of 27
In order to assess any potential health risks within a building, it is necessary to conduct a survey of the building to identify and locate any friable or non-friable asbestos containing materials (ACM) that may be located within.
If and when ACM are located within a building, the ACM must then be evaluated and assessed to determine whether any immediate health hazards are presented to the building occupants. It must be noted that the presence of asbestos in a building does not necessarily mean that the health of the building occupants is endangered. As long as an ACM remains intact (in good condition and is not disturbed, damaged, or mutilated) exposure of asbestos fibers to the air is unlikely.
HEALTH EFFECTS OF ASBESTOS EXPOSURE
The potential health hazards associated with exposure to asbestos results from inhalation of airborne fibers; small asbestos fibers can pass readily through the upper respiratory tract and be deposited in the terminal bronchioles of the lung. There they can produce a local irritation which the body attempts to neutralize by initiating a tissue response. The resulting body response is encapsulation of the fibers and consequent formation of "asbestos nodules."
Common asbestos related diseases include:
Lung Cancer
Mesothelioma
Asbestosis
Chronic Obstructive Pulmonary Disease (COPD)
C-2: Asbestos Testing
SAMPLING
Representative bulk samples of suspected ACBMs were randomly collected within each building area. The materials sampled were broken down into distinct homogenous (similar) materials.
Homogenous material determination was based on the following criteria:
Similar physical characteristics (same color and texture, etc.)
Application (sprayed-on, troweled-on, assembly into a system etc.)
Material function (Thermal insulation, floor tile, wallboard system etc.)
While the NESHAP regulation allows for the taking of one sample of select non-friable materials, the OSHA standard suggests a minimum of three samples of each homogeneous material be taken. This is a better approach due the potential errors in the analytical method used.
To provide the most accurate information possible and be sure of our results, ETC may choose to take three samples of each material.
If materials are being assumed to contain asbestos, they must be treated as asbestos containing, even if they are not. This can lead to significantly increased costs for the building owner.
In general, ETC only assumes materials to be asbestos when sampling them will ruin their integrity (i.e. fire doors) or when they are too dangerous to sample (i.e. live electrical lines).
ETC Job #: 261660 Page 20 of 27
FOLLOW-UP INSPECTIONS
In some cases, ETC may identify areas where destructive access was required to review materials that were not readily accessible. In these cases, a follow-up inspection may be required once access to these areas is granted in order to assess these previously inaccessible areas.
Additionally, materials that were deemed to be positive for asbestos content during the initial survey will need to be quantified and have their conditions assessed in a follow-up inspection.
PLM ANALYSIS METHODOLOGY
Bulk samples submitted for Polarized Light Microscopy (PLM) analysis were analyzed utilizing the Environmental Protection Agency’s Test Method: Method for the determination of Asbestos in Bulk Building Materials (EPA 600/R-93/116, July 1993). Additional treatment and tests may be required to accurately define composition (e.g. ashing, fiber extraction, acid dissolution, TEM).
Analysis was performed by visual and stereoscopic examination of the bulk sample followed by microscopic examination and quantification using a polarized light microscope. The samples were analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite, and actinolite/tremolite), fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents.
According to NESHAP requirements, any bulk sample that has an asbestos content above 0% but below 10% should be point counted for final determination of percentage. Please note, that when a contract DOES NOT include point counting as defined in NESHAP, and additional analysis is desired, ETC can send any samples in this range for point counting. However, this will require additional charges for analysis. Therefore, for any samples in the range above 0% but below 10%, these results can only be considered estimates.
INTERPRETATION OF INSPECTION RESULTS
A material is considered by the EPA, OSHA, and other federal, state, and local agencies to be asbestos-containing if at least one sample collected from the homogenous material has asbestos fibers present in a concentration greater than one percent (>1 %).
However, materials with concentrations greater than zero percent (0%) but less than or equal to one percent (≤1%), will now be considered regulated under certain sections of the OSHA Asbestos in Construction Standard (29 CFR 1926.1101).
The standard contains numerous work practice requirements and prohibitions which apply, regardless of the exposure levels. However, only two of the requirements and three of the prohibitions must be observed in the case of work activities involving installed construction materials that do not contain >1% asbestos. Those work practice requirements and prohibitions that must be observed regardless of the exposure levels and of the percentage of asbestos in the installed construction materials are:
29 CFR 1926.1101(g)(1)(ii), which requires: wet methods, or wetting agents, to control employee exposures during asbestos handling, mixing, removal, cutting, application, and cleanup, except where employers demonstrate that the use of wet methods is infeasible
ETC Job #: 261660 Page 21 of 27 due to, for example, the creation of electrical hazards, equipment malfunction, and, in roofing, except as provided in paragraph (g)(8)(ii)2 of this section;
29 CFR 1926.1101(g)(1)(iii), which requires: prompt clean-up and disposal of wastes and debris contaminated with asbestos in leak-tight containers except in roofing operations, where the procedures specified in paragraph (g)(8)(ii)3 of this section apply;
29 CFR 1926.1101(g)(3)(i), which prohibits: high-speed abrasive disc saws that are not equipped with point-of-cut ventilator or enclosures with HEPA filtered exhaust air;
29 CFR 1926.1101(g)(3)(ii), which prohibits: compressed air used to remove asbestos, or materials containing asbestos, unless the compressed air is used in conjunction with an enclosed ventilation system designed to capture the dust cloud created by the compressed air; and
29 CFR 1926.1101(g)(3)(iv), which prohibits: employee rotation as a means of reducing employee exposure to asbestos.
There are also some other provisions that apply to work activities involving installed construction materials even where the material does not contain >1% asbestos. However, if neither asbestos PEL is exceeded, only the following few provisions apply:
29 CFR 1926.1101(f)(2)(i), the provision for establishing that neither asbestos PEL is exceeded: Each employer who has a workplace or work operation covered by this standard shall ensure that a "competent person" conducts an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace. The assessment must be completed in time to comply with requirements which are triggered by exposure data or the lack of a "negative exposure assessment," and to provide information necessary to assure that all control systems planned are appropriate for that operation and will work properly;
29 CFR 1926.1101(f)(6)(i), a provision covering the observation of monitoring: The employer shall provide affected employees and their designated representatives an opportunity to observe any monitoring of employee exposure to asbestos conducted in accordance with this section;
29 CFR 1926.1101(f)(5)(i), a provision covering employee notification of monitoring results: The employer shall notify affected employees of the monitoring results that represent that employee's exposure as soon as possible following receipt of monitoring results;
29 CFR 1926.1101(f)(5)(ii), another provision covering employee notification of monitoring results: The employer shall notify affected employees of the results of monitoring representing the employee's exposure in writing either individually or by posting at a centrally located place that is accessible to affected employees; and
29 CFR 1926.1101(n)(2)(i)-(iii), a set of provisions covering recordkeeping for measurements of exposures to airborne asbestos.
There are numerous additional provisions of the standard that apply to work activities involving installed construction materials even where the material does not contain >1% asbestos if at least one of the asbestos PELs is exceeded.
ETC Job #: 261660 Page 22 of 27
A letter of interpretation from Federal OSHA authorities that explains this position can be found by following the link below:
https://www.osha.gov/laws-regs/standardinterpretations/2003-11-24-0
Note: A summary of the materials sampled, asbestos content, quantities and locations can be found in Table 1.
C-3: Other Hazardous Materials and Vermiculite
Hazardous Materials
Additionally, information showing other hazardous materials (above the household quantity limitations) found at the site is included in Table 2. This lists non-asbestos materials that may be hazardous, and may require special handling and disposal requirements. Items that might be in this category include things like tires, mercury switches, florescent lighting tubes, halogen lights, Freon in refrigeration units, pesticides, herbicides, paints, solvents, etc.
However, under the Resource Conservation and Recovery Act (RCRA) that addresses hazardous wastes, there is residential household quantity exclusion. Therefore, these materials will only be listed in this chart if they are present in quantities larger than what would be expected in a normal household. For instance, if the home was a farm and had a 55-gallon drum of pesticide present, this would be listed in Table 2. On the other hand, if there were a few pesticide containers present as would be found in most homes, these materials would not be listed.
Vermiculite
The EPA is informing the public to consider all vermiculite insulation as ACM, and is doing so because the current method is not accurate and yields false negatives when used on vermiculite.
However, the current standard PLM and point count methods satisfy the minimum EPA regulatory requirements for analysis of vermiculite loose fill insulation under 40 CFR part 61, subpart M. The EPA plans on publishing an analysis method that will be more accurate for vermiculite insulation. Upon its publishing, this method will supersede the current methods and continue use of the old methods will be subject to enforcement action.
ETC Job #: 261660 Page 23 of 27
C-4: Additional Resources
Additional information about asbestos is available on the Internet through the U.S. EPA’s homepage (www2.epa.gov/asbestos). Demolition specific information can be found at https://www.epa.gov/large-scale-residential-demolition/asbestos-containing-materials-acm-and-demolition.
Questions about the federal OSHA standards or the state’s asbestos compliance and training requirements can be obtained by visiting the LARA Asbestos Program’s web site at https://cdphe.colorado.gov/indoor-air-quality/asbestos-general-information. Questions related to the transportation of asbestos can be addressed by the U.S. Department of Transportation’s (U.S. DOT) Hazmat Information Center at 800-467-4922.
Head to https://cdphe.colorado.gov/indoor-air-quality/asbestos-general-information. for a list of
Colorado asbestos abatement contractors.
A “Notification of Intent to Renovate/Demolish” form can be found online at https://cdphe.colorado.gov/indoor-air-quality/asbestos-general-information.
Additional information about vermiculite is available on the EPA’s website and is located at https://www.epa.gov/asbestos/protect-your-family-asbestos-contaminated-vermiculite-insulation.
C-5: Regulatory Information
The Environmental Protection Agency (EPA) set the standard for asbestos surveys in the AHERA regulations (40 CFR Part 763) which required surveys of all school buildings in the United States.
Additionally, the Department of Occupational Safety and Health (OSHA) has also passed regulations affecting the performance of asbestos surveys in buildings. According to current OSHA regulations (29 CFR 1926.1101), building owners must inform occupants of the location, quantity and condition of confirmed or assumed asbestos containing materials within all public and commercial facilities.
In addition to these regulations regarding surveys, facility owners and operators are also required to insure that employees or occupants of their buildings are not exposed to unsafe levels of airborne asbestos. Allowable fiber levels as defined by the regulatory agencies and standards below dictate which levels are applicable in which facilities:
0.01 f/cc - Environmental Protection Agency (EPA) Clean Air Standard
This standard was designed as a clearance criterion for asbestos removal projects in schools.
This means that if a removal project occurs in a school, air testing must be conducted in the
ETC Job #: 261660 Page 24 of 27 removal area after work is completed. The results of this sampling must be below this level in order to allow re-occupancy of this area.
0.10 f/cc - Occupational Safety and Health Administration (OSHA) Personal Exposure Level
This is the OSHA permissible exposure limit (PEL) average over an 8-hour day. This means that this is the maximum level of asbestos that workers and/or employees can be exposed to without respirator protection and protective clothing. Should air sampling be at or near the PEL the employer will have to:
Implement Worker Training
Conduct Employee Respiration Monitoring
Perform Recordkeeping
Conduct Medical Surveillance
Notify Workers
Post Danger Signs
Perform periodic air monitoring, establish regulated areas, and construct decontamination facilities
Provide respiratory protection and personnel protective clothing
For these reasons, it is important that building owners conduct a combination of a complete asbestos bulk survey and periodic air monitoring to determine what types of asbestos containing materials (ACM) are present in their building, what condition these materials are in and to what extent these materials have become airborne.
ETC Job #: 261660 Page 25 of 27
APPENDIX D – COLORADO ASBESTOS CERTIFICATION
ETC Job #: 261660 Page 26 of 27
ETC Job #: 261660 Page 27 of 27
APPENDIX E – LABORATORIES USED & ORIGINAL LABORATORY
ANALYSIS REPORTS
E-1: Laboratory Used Environmental Testing Laboratories
37575 West Huron River Drive
Romulus, MI 48174
1-734-955-6600
E-2: Original Laboratory Analysis Reports All of the original laboratory analysis reports for any samples that were sent for testing are included in the following pages.
DISCLAIMER:
The information contained herein is accurate for conditions present at the time of the investigation. In addition, ETC will not be held liable for incorrect or inaccurate information provided by the client, occupant, or property owner, or the recommendations based on that incorrect or inaccurate information.
This report (including any enclosures and attachments) has been prepared for the exclusive use and benefit of the addressee(s) and solely for the purpose for which it is provided.
Unless ETC provides express prior written consent, no part of this report should be reproduced, distributed or communicated to any third party. ETC does not accept any liability if this report is used for an alternative purpose from which it is intended, nor to any third party in respect of this report.
ETC cannot be held responsible for materials encountered after the initial survey is completed unless we are contacted and given the opportunity to test and verify the material content. The costs associated with this additional testing are not included within the scope of this project and the addressee(s)/and or client will incur additional charges for the additional sampling and analysis.
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Environmental Testing And Consulting Inc.
38900 Huron River Drive
Romulus, MI 48174
Project Location:
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
Client Project: 261660
261660ETL Job:
Douglas Smith (COR)
Lab Sample Number Client Sample Number Sample Type Completed
1588832 Asbestos01A 10/31/2023
1588833 Asbestos01B 10/31/2023
1588834 Asbestos01C 10/31/2023
1588835 Asbestos02A 10/31/2023
1588836 Asbestos02B 10/31/2023
1588837 Asbestos02C 10/31/2023
1588838 Asbestos03A 10/31/2023
1588839 Asbestos03B 10/31/2023
1588840 Asbestos03C 10/31/2023
1588841 Asbestos04A 10/31/2023
1588842 Asbestos04B 10/31/2023
1588843 Asbestos04C 10/31/2023
1588844 Asbestos05A 10/31/2023
1588845 Asbestos05B 10/31/2023
1588846 Asbestos05C 10/31/2023
1588847 Asbestos06A 10/31/2023
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type Completed
1588848 Asbestos06B 10/31/2023
1588849 Asbestos06C 10/31/2023
1588850 Asbestos07A 10/31/2023
1588851 Asbestos07B 10/31/2023
1588852 Asbestos07C 10/31/2023
1588853 Asbestos08A 10/31/2023
1588854 Asbestos08B 10/31/2023
1588855 Asbestos08C 10/31/2023
1588856 Asbestos09A 10/31/2023
1588857 Asbestos09B 10/31/2023
1588858 Asbestos09C 10/31/2023
1588859 Asbestos10A 10/31/2023
1588860 Asbestos10B 10/31/2023
1588861 Asbestos10C 10/31/2023
1588862 Asbestos11A 10/31/2023
1588863 Asbestos11B 10/31/2023
1588864 Asbestos11C 10/31/2023
1588865 Asbestos12A 10/31/2023
1588866 Asbestos12B 10/31/2023
1588867 Asbestos12C 10/31/2023
1588868 Asbestos13A 10/31/2023
1588869 Asbestos13B 10/31/2023
1588870 Asbestos13C 10/31/2023
1588871 Asbestos14A 10/31/2023
1588872 Asbestos14B 10/31/2023
1588873 Asbestos14C 10/31/2023
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Lab Sample Number Client Sample Number Sample Type Completed
1588874 Asbestos15A 10/31/2023
1588875 Asbestos15B 10/31/2023
1588876 Asbestos15C 10/31/2023
1588877 Asbestos16A 10/31/2023
1588878 Asbestos16B 10/31/2023
1588879 Asbestos16C 10/31/2023
1588880 Asbestos17A 10/31/2023
1588881 Asbestos17B 10/31/2023
1588882 Asbestos17C 10/31/2023
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 57Jessica Dilworth
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588832
01A PLM 100% OtherWhiteDrywall
Non-Fibrous
HomogenousFS15 N Wall
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588832
01A PLM 100% Other fibrousYellowTape
Fibrous
HomogenousFS15 N Wall
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588832
01A PLM 100% OtherWhiteMud
Non-Fibrous
HomogenousFS15 N Wall
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588833
01B PLM 100% OtherWhiteDrywall
Non-Fibrous
HomogenousFS15, Closet
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588833
01B PLM 100% Other fibrousYellowTape
Fibrous
HomogenousFS15, Closet
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588833
01B PLM 100% OtherWhiteMud
Non-Fibrous
HomogenousFS15, Closet
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588834
01C PLM 100% OtherWhiteDrywall
Non-Fibrous
HomogenousFS13, near W Door
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588834
01C PLM 100% Other fibrousYellowTape
Fibrous
HomogenousFS13, near W Door
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588834
01C PLM 100% OtherWhiteMud
Non-Fibrous
HomogenousFS13, near W Door
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM 4% Chrysotile1588835
02A PLM 96% OtherBrown/RedLineoleum and Fiber Backing and Mastic Non-Fibrous
Non-HomogenousFS11 near Door
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
1588836
02B
Positive Stop
FS11 Center
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
1588837
02C
Positive Stop
FS11 near Tub
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM 3% Chrysotile1588838
03A PLM 97% OtherRedLineoleum and Fiber Backing
Non-Fibrous
Non-HomogenousFS10 near Door
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
1588839
03B
Positive Stop
FS10 Center
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
PLM None Detected 1588839
03B PLM 100% OtherTanMastic
Non-Fibrous
HomogenousFS10 Center
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
1588840
03C
Positive Stop
FS10 near Tub
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
PLM None Detected 1588840
03C PLM 100% OtherTanMastic
Non-Fibrous
HomogenousFS10 near Tub
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588841
04A PLM 88% OtherPLM 10% Cellulose
PLM 2% Fiberglass
BeigeLineoleum and Fiber Backing
Non-Fibrous
Non-HomogenousFS15 E Steps
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588842
04B PLM 88% OtherPLM 10% Cellulose
PLM 2% Fiberglass
BeigeLineoleum and Fiber Backing and Mastic Non-Fibrous
Non-HomogenousFS15 N Entry
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588843
04C PLM 88% OtherPLM 10% Cellulose
PLM 2% Fiberglass
BeigeLineoleum and Fiber Backing and Mastic Non-Fibrous
Non-HomogenousFS15 SW Corner
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM 6% Chrysotile1588844
05A PLM 94% OtherBrownLineoleum and Fiber Backing and Mastic Non-Fibrous
Non-HomogenousFS15 E Entry
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
1588845
05B
Positive Stop
FS12 W Entry
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
1588846
05C
Positive Stop
FS12 S Side
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
Layer Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588847
06A PLM 100% OtherBrownCeramic Tile
Non-Fibrous
HomogenousFS4 near W Wall
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588847
06A PLM 100% OtherGrayGrout and Mortar
Non-Fibrous
Non-HomogenousFS4 near W Wall
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588847
06A PLM 100% OtherTanMastic
Non-Fibrous
HomogenousFS4 near W Wall
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588848
06B PLM 100% OtherBrownCeramic Tile
Non-Fibrous
HomogenousFS4 near W Wall
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588848
06B PLM 100% OtherGrayGrout and Mortar
Non-Fibrous
Non-HomogenousFS4 near W Wall
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588848
06B PLM 100% OtherTanMastic
Non-Fibrous
HomogenousFS4 near W Wall
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588849
06C PLM 100% OtherBrownCeramic Tile
Non-Fibrous
HomogenousFS4 near W Wall
Layer-1 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588849
06C PLM 100% OtherGrayGrout and Mortar
Non-Fibrous
Non-HomogenousFS4 near W Wall
Layer-2 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588849
06C PLM 100% OtherTanMastic
Non-Fibrous
HomogenousFS4 near W Wall
Layer-3 Analyst: Lili Calderon-Moscrip
Date Analyzed : 10/31/2023
PLM None Detected 1588850
07A PLM 100% OtherPLM Trace CelluloseBrownCove Base
Non-Fibrous
HomogenousFS2 W Cabinets
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588851
07B PLM 100% OtherPLM Trace CelluloseBrownCove Base
Non-Fibrous
HomogenousFS2 E Cabinets
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588852
07C PLM 100% OtherPLM Trace CelluloseBrownCove Base
Non-Fibrous
HomogenousFS12 S Wall
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588853
08A PLM 95% OtherPLM 5% CelluloseYellowMastic
Non-Fibrous
HomogenousFS2 W Cabinets
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588854
08B PLM 95% OtherPLM 5% CelluloseYellowMastic
Non-Fibrous
HomogenousFS2 E Cabinets
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588855
08C PLM 95% OtherPLM 5% CelluloseYellowMastic
Non-Fibrous
HomogenousFS12 S Wall
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM 25% Chrysotile1588856
09A PLM 65% OtherPLM 10% CelluloseOrange/ BrownLinoleum
Fibrous
Non-HomogenousFS2 N Entry
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
1588857
09B
Positive Stop
FS2 S Entry
Analyst: Emily Spotts
Date Analyzed : 10/31/2023
Sample Not Analyzed
1588858
09C
Positive Stop
FS2 W Cabinets
Analyst: Emily Spotts
Date Analyzed : 10/31/2023
Sample Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
20 Various Buildings
Alamosa NWR QTRS #1, Mobile Home Double Wide D
ETL Job :
Client Project :
261660
261660
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/17/2023
10/24/2023
Date Collected :
Date Received :
PLM None Detected 1588859
10A PLM 10% OtherPLM 90% CelluloseWhitePaneling
Fibrous
HomogenousFS2 Ceiling
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588860
10B PLM 10% OtherPLM 90% CelluloseWhitePaneling
Fibrous
HomogenousFS1 Ceiling
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588861
10C PLM 10% OtherPLM 90% CelluloseWhitePaneling
Fibrous
HomogenousFS5 Ceiling
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588862
11A PLM 100% OtherPLM Trace CelluloseGrayCinder Block
Non-Fibrous
HomogenousExterior NE Corner
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588863
11B PLM 100% OtherPLM Trace CelluloseGrayCinder Block
Non-Fibrous
HomogenousExterior SE Corner
Layer-1 Analyst: Emily Spotts
Date Analyzed : 10/31/2023
PLM None Detected 1588864
11C PLM 100% OtherPLM Trace CelluloseGrayCinder Block
Non-Fibrous
HomogenousExterior SW Corner
Layer-1…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .