This is a Limited Asbestos Building Material Survey and Limited Lead-Based Paint Sampling Report prepared by Advantage Environmental, Inc. for the U.S. Fish and Wildlife Services regarding the Spring Creek National Fish Hatchery Incubation Building located at 61552 State Road 14 in Underwood, Washington. The survey was conducted on June 24, 2020, by EPA/AHERA accredited building inspector Eric Neil. The inspection identified the structure as a single-story commercial building of approximately 10,000 square feet constructed of brick on a concrete slab with plaster walls and tile ceilings and floors.

Laboratory analysis of 25 bulk samples identified two materials containing asbestos at levels of 1% or greater that require removal prior to any renovation, demolition, or repair work: brown ceiling tile mastic located in the laboratory containing 2% Amosite (approximately 160 square feet in fair condition, non-friable), and 12-inch beige floor tile with black flooring mastic located in the laboratory, locker room/restroom, and vestibule containing 2% Chrysotile and 6% Chrysotile respectively (approximately 220 square feet in fair condition, non-friable). Lead-based paint sampling identified three painted surfaces with elevated lead content: interior wall in the south lab at 1,100 ppm, interior trim on the lab door frame at 13,000 ppm, and interior trim on the locker room door at 9,900 ppm. The report notes that additional asbestos-containing materials may exist in concealed areas and recommends that an OSHA-licensed asbestos abatement contractor perform any removal work using appropriate engineering controls, wet methods, negative pressure enclosure, and decontamination procedures.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIMITED ASBESTOS

BUILDING MATERIAL SURVEY

LIMITED LEAD BASED PAINT

SAMPLING REPORT

Conducted at:

Spring Creek National Fish Hatchery-Incubation Building 61552 State Road 14

Underwood, WA 98651

Conducted for:

U.S. Fish and Wildlife Services 61552 State Road 14

Underwood, WA 98651

Prepared By:

Advantage Environmental Inc.

9317 NE Hwy 99, Suite D

Vancouver, WA 98665

June 26, 2020

Columbia River Gorge National Fish Hatchery Complex U.S. Fish and Wildlife Services David Carie 61552 State Road 14 Underwood, WA 98651 David_carie@fws.gov 509-493-1730

Re: Limited Asbestos Material Survey & Limited Leadbased paint sampling:

Spring Creek National Fish Hatchery Incubation Building 61552 State Road 14 in Underwood, WA

Dear Mr. Carie, Advantage Environmental, Inc., (AEI) has completed a limited asbestos material survey & limited lead-based paint sampling of the Spring Creek National Fish Hatchery within the Incubation building located at 61552 State Road 14 in Underwood, WA. The results of the survey are provided in the accompanying report.

Thank you for choosing Advantage Environmental for this project. Please feel free to contact us at (360) 356-7628 if you have any questions.

Respectfully, Advantage Environmental, Inc.

Cody Clarke Project Manager mailto:David_carie@fws.gov

1. INTRODUCTION

Advantage Environmental, Inc. (AEI) was retained by U.S. Fish and Wildlife Services to perform a limited asbestos building materials survey & limited lead-based paint sampling of the Spring Creek National Fish Hatchery within the incubation building located at 61552 State Road 14 in Underwood, WA. The on-site inspection was performed by EPA/AHERA accredited building inspector Eric Neil on June 24, 2020.

2. BUILDING DESCRIPTION

The structure is a commercial building currently occupied as an Incubation building. The structure is single-story ~10,000 sq. ft. brick built on concrete slab. Interior walls consisted of plaster and ceilings consisted of tile. The floors were concrete with tile.

3. PURPOSE AND SCOPE

The purpose of this survey was to identify the location of asbestos containing materials prior to renovation of building materials within the structure. The scope of work included a walk-through inspection, bulk sampling and analysis of specific suspect asbestos-containing materials with a written report documenting the results of the survey.

This is not a bidding document and all quantities of asbestos containing materials should be verified by the abatement contractor prior to submitting their bid.

4. VISUAL ASSESSMENT AND FINDINGS

Our survey activities began with visual observation of the interior of the structure to identify homogeneous areas of suspect asbestos containing materials. Interior assessments were conducted throughout visually accessible areas of the buildings.

Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect asbestos containing materials.

Unidentified asbestos-containing materials may be in place behind walls, ceilings, under floors, beneath carpeted areas, areas thought not to be deemed necessary at the time of inspection and in other inaccessible areas.

A table indicating sample numbers, material description, material location, material condition and asbestos content of each material sampled is included in Appendix A. Laboratory analytical results and chain of custody documentation are included in Appendix B.

Comments, notes and other documents are included in Appendix C. AHERA Building inspector credentials are included in Appendix D.

Additional asbestos-containing materials may be in place behind/beneath floors, wall ceiling, debris or in areas deemed unnecessary at the time of inspection by the property owner/representative.

Suspect asbestos-containing materials sampled and analyzed included:

• White skim coat

• White plaster

• 12” White ceiling tile

• Brown ceiling mastic

• Tan brick

• Gray mortar

• Red brick

• 12” Beige floor tile

• Black flooring mastic

• Tan ceramic tile

• White mortar

• Green ceramic floor tile

• Red pipe

• White/pink/brown insulation

Of the suspect asbestos-containing materials sampled, laboratory analysis indicated the following materials contained asbestos content of 1% or greater. These materials will need to be removed prior to disturbance, construction or demolition activities that may impact these materials.

Material Type

Material Location

Condition

% of

Asbestos

Approximate

Quantity**

Friable

Yes / No

Brown ceiling tile mastic

Laboratory

Fair

2% Amosite

~160 sq. ft.

No

12” Beige floor tile Black flooring mastic

Laboratory, locker room/restroom & vestibule

2% Chrysotile 6% Chrysotile

~220 sq. ft.

No

Note: A diligent inspection was conducted and every effort was made to inspect and investigate all areas of the aforementioned building(s).

However, unidentified asbestos-containing materials may still be in place behind walls, under floors, cabinets, above ceilings, etc., and/or in other areas of the structure inspected that were inaccessible/not included at the time of this survey.

**Quantities based on visual observations at time of inspection, additional quantities may be in concealed areas. All quantities should be verified prior to removal.

Limited sampling for lead-based paint was also conducted as part of this survey. Sample results with a “less than” (<) sign indicate the sample results were below the laboratories reporting limit. See laboratory results for more information. Painted surfaces that were sampled are listed below with their corresponding analytical result.

Sample – Color

Paint Location

Results (PPM) Parts Per

Million

Pb-1-White Interior-Wall-South Lab by door 1,100 Pb-2-White Interior-Trim-Lab door frame 13,000 Pb-3-Green Interior-Trim-locker room door 9,900

Care should be exercised while disturbing the lead-based paint by trained personnel. Paint may be located in other areas of the buildings in addition to the specific areas observed.

Interior finishing had appeared to be newer. Loose failing paint may be required to be removed prior to disturbance.

5. SAMPLING METHODOLOGY

A walk-through of the structure was conducted by an EPA/AHERA accredited building inspector to identify the location of suspect asbestos-containing materials. The location, approximate quantity and condition of each material were recorded on field data sheets. Bulk samples of each suspect material were then collected and submitted to the laboratory under chain of custody documentation for analysis of asbestos content.

Samples were collected from selected homogeneous materials in order to evaluate the presence or absence of asbestos in each material. Determination of homogeneous materials included material type, texture, pattern, color, and size. A total of 25 suspect asbestos-containing material samples were analyzed including sub-layers.

All samples collected by AEI were placed into pre-labeled airtight containers and dropped off at AEI’s Laboratory for analysis of asbestos content. AEI analyzed the samples using Polarized Light Microscopy (PLM) with dispersion staining to identify asbestos constituents as required by EPA regulation 40 CFR, Part 763.

Lead Collected samples were placed into pre-labeled airtight containers and shipped to Quantem Laboratories located in Oklahoma City, Oklahoma for analysis of lead content. Lead sampling not to meet Target Housing, HUD or Washington Department of Commerce guidelines or regulations.

6. DISCUSSION & RECOMMENDATIONS

Asbestos-containing material must be removed by a licensed asbestos abatement contractor prior to any renovation, demolition or repair work that will impact those material.

Any material encountered that are not specifically mentioned in this report should be considered asbestos containing until sufficient sampling has been completed to determine that these materials are non-asbestos containing.

The Occupational Safety and Health Administration (OSHA) classify the removal or disturbance of asbestos containing material as Class I and Class II asbestos abatement projects. The removal of asbestos containing material requires the use of appropriate engineering controls, by a contractor licensed by the State of Washington. The work methods utilized must include the use of wet methods, negative pressure enclosure, and decontamination facility.

The Environmental Protection Agency (EPA) and Southwest Washington Clean Air Agency (SWCAA) do not consider building materials that contain <1% asbestos to be asbestos containing.

Additionally, OSHA regulations (29 CFR 1926.1101) require employers to meet standards regarding personal protection, labeling, signs, daily air monitoring, use of engineering controls, notification, and respiratory protection for all activities related to the removal or disturbance of asbestos containing building material.

Lead-based paint that will be disturbed by demolition activities, care must be taken to avoid possible lead exposure to workers or building occupant during the demolition. Employers of workers who may be exposed to lead in the course of their work are required to demonstrate that their employees are not being exposed to lead above the Permissible Exposure Limit (PEL) established by OSHA.

7. WARRANTY

Advantage Environmental Inc. warrants that this report has been prepared in a manner consistent with that degree of care and skill ordinarily exercised by members of the same profession currently practicing under similar circumstances. No other warranties are implied or expressed.

APPENDIX A

Material Summary Table

61552 State Road 14 Underwood, WA Spring Creek National Fish Hatchery-Incubation Building

Material Summary Table

Sample Number

Material Description Sample Location Condition if applicable

Asbestos Content

1A

1B

1C

White skim coat White plaster White skim coat White plaster White skim coat White plaster

Laboratory-mid West Wall-beneath window Laboratory-mid West Wall-beneath window Laboratory-NE Ceiling-above tile Laboratory-NE Ceiling-above tile Locker room restroom vestibule-mid West Wall Locker room restroom vestibule-mid West Wall

Asbestos Not Present Asbestos Not Present Asbestos Not Present Asbestos Not Present Asbestos Not Present

2A

2B

2C

12” White ceiling tile Brown ceiling mastic 12” White ceiling tile Brown ceiling mastic 12” White ceiling tile Brown ceiling mastic

Laboratory-NE Laboratory-NE Laboratory-debris Laboratory-debris Laboratory-SW Laboratory-SW

2% Amosite

Asbestos Not Present 2% Amosite

2% Amosite

Tan brick Gray mortar

Locker room-by shower Locker room-by shower

Red brick Gray mortar

Locker room-North Wall-by door Locker room-North Wall-by door

12” Beige floor tile Black flooring mastic Tan ceramic tile White mortar

Laboratory-SW (also locker room-restroom vestibule) Laboratory-SW (also locker room-restroom vestibule) Laboratory-SW (also locker room-restroom vestibule) Laboratory-SW (also locker room-restroom vestibule)

Fair Fair

2% Chrysotile 6% Chrysotile

Green ceramic floor tile White grout

Locker room-NW (also restroom) Locker room-NW (also restroom)

Red pipe Gray grout

Locker room-South Wall-by attic access Locker room-South Wall-by attic access

8 White/pink/brown insulation Attic-at access Asbestos Not Present

APPENDIX B

Laboratory Analytical Results

Chain of Custody

Chain of Custody

Property Address:

Date Analyzed:

009B Layered Tan Ceramic Tile Asbestos Not Present N/A Clay

009 5 Layered Beige Floor Tile 2% Chrysotile N/A Vinyl-CaCO3

009A Layered Black Flooring Mastic 6% Chrysotile N/A Tar

008 4 Layered Red Brick Asbestos Not Present N/A Clay-CaCO3

008A Layered Gray Mortar Asbestos Not Present N/A CaCO3-Sand

007 3 Layered Tan Brick Asbestos Not Present N/A Clay

007A Layered Gray Mortar Asbestos Not Present N/A CaCO3-Sand

006 2C Layered White Ceiling Tile Asbestos Not Present 80% Glass Fibers Paint-CaCO3

006A Layered Brown Ceiling Mastic 2% Amosite 2% Wollastonite Glue

005 2B Layered White Ceiling Tile Asbestos Not Present 80% Glass Fibers Paint-CaCO3

005A Layered Brown Ceiling Mastic 2% Amosite 2% Wollastonite Glue

004 2A Layered White Ceiling Tile Asbestos Not Present 80% Glass Fibers Paint-CaCO3

004A Layered Brown Ceiling Mastic 2% Amosite 2% Wollastonite Glue

003 1C Layered White Skim Coat Asbestos Not Present N/A Paint-CaCO3-Sand

003A Layered White Plaster Asbestos Not Present N/A CaCO3-Sand

002 1B Layered White Skim Coat Asbestos Not Present N/A Paint-CaCO3-Sand

002A Layered White Plaster Asbestos Not Present N/A CaCO3-Sand

Non-Asbestos Fiber (%)

Non Fibrous

CaCO3-Sand

9317 NE Hwy 99, Suite D, Vancouver, WA 98665 | 360-356-7628

Polarized Light Microscopy Results

Asbestos Not Present Paint-CaCO3-SandN/ALayered

Asbestos Not Present N/A

61552 State Rd

Underwood, WACity, State, Zip:

Jorge - (541) 806-2962

US Fish & Wildlife Services

Asbestos (%)Composition

Job Number: Springcreek National Fish Hatchery

Sample ID

AEI

001A

1A White Skim Coat

Layered White Plaster

Sample ID Client Color/

Description

Lab No:

Date Received:

Received By:

Analyzed By:

6/25/2020

Nathan Blondino

Client Name:

Client Address:

City, State, Zip:

Phone & E-mail:

126941

6/24/2020

Bekah Barnes

Property Address: Lab No: 126941

Sample ID

AEI

009C

010 6

White Mortar

Sample ID Client Color/

Description Non-Asbestos

Fiber (%) Non Fibrous

Clay-CaCO3

9317 NE Hwy 99, Suite D, Vancouver, WA 98665 | 360-356-7628

Polarized Light Microscopy Results

Asbestos Not Present CaCO3-SandN/ALayered

Asbestos Not Present N/A

61552 State Rd, Underwood, WA

Asbestos (%)Composition

Page Number

Layered Green Ceramic Floor Tile

010A Layered White Grout Asbestos Not Present N/A CaCO3-Sand

011 7 Layered Red Pipe Asbestos Not Present N/A Clay-CaCO3

011A Layered Gray Grout Asbestos Not Present N/A CaCO3-Sand

012 8 Homogeneous White/Pink/Brown

Insulation Asbestos Not Present 95% Glass Fibers Debris

Acct. No.:

Project: 61552 State Road 14

Location:

Project No.:

QuanTEM Set ID: 324020

Date Received: 06/25/20

Received By: Christiana Younge

Date Sampled:

Time Sampled:

Date of Report: 06/25/20

B513

Underwood, WA

U.S. Fish and Wildlife

Matrix Parameter Results Units MethodClient ID

QuanTEM

ID

Reporting

Limits

Date/Time

Analyzed

Environmental Chemistry Analysis Report

Client: Advantage Environmental, Inc.

Chelsea Moore

Analyst: CR

AIHA-LAP, LLC: 101352

Lead 1,100 50 ppm 06/25/20 16:03 P EPA 7000B (1)PaintPB-1001

Lead 13,000 50 ppm 06/25/20 16:03 P EPA 7000B (1)PaintPB-2002

Lead 9,900 50 ppm 06/25/20 16:03 P EPA 7000B (1)PaintPB-3003

Authorized Signature:_______________________________________________

Cherry Rossen, Technical Manager

Note: Sample results have not been corrected for blank values.

This report applies only to the standards or procedures indicated and to the specific samples tested. It is not indicative of the qualities of apparently identical or similar products or procedures, nor does it represent an ongoing assurance program unless so noted. These reports are for the exclusive use of the client and are not to be reproduced without specific written permission. QuanTEM is not responsible for user-supplied data used in calculations.

Customer provided data such as volumes, areas, etc., cannot be verified by QuanTEM Laboratories, LLC.

Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.

Wipe materials must meet ASTM E1792 criteria. Method detection limits and resultant reporting limits may not be valid for non-ASTM E1792 wipe material.

EPA Method 7000B (1) = EPA 600/R-93/200 Preparation Modified. EPA 7000B Analysis Modified

EPA Method 7082 (2) = EPA 600/R-93/200 Preparation Modified. EPA 7082 Analysis Modified

Supplemental Report

QAQC Results QA ID: 18588 Date: 6/25/2020

Test: Lead

Notes:

Approved By: Cherry Rossen

Date Approved: 6/25/2020

Blank Data:

Duplicate Data:

Recovery Data:

Standards Data:

Lab Number: 324020

Matrix: Paint

Type of Blank Blank Value

0FCB

0ICB

0Matrix Blank

Sample Number Result Spike Level Result +

Spike

Dup. Result +

Spike

% Spike RPD% Recovery % Dup.

Recovery

1.992 2.0280.000 1.798101.8 90.3 12.0LCS-P1

2.000 2.3890.370 101.0323015-004

Standard Low Limit Obtained High Limit

4.5 5.55CCV

4.5 5.55.1FCV

0.9 1.11ICV

Authorized Signature:_______________________________________________

Cherry Rossen, Technical Manager

APPENDIX C

Comments/Notes Other Documents

APPENDIX C

AHERA Building Inspector

Certification

Insert from: "Inspector notes.pdf"
doc20200625110729.pdf
doc20200625110706.pdf
Insert from: "61552 State Road 14 Underwood, WA Labs& COC.pdf"
Lab Results Page 1.pdf
Lab Results Page 2.pdf
61552 State Rd 14, Underwood, WA - COC.pdf

File details come from the government source that posted it. Updated .