B09_Amd_5_Drawings_0005.pdf
PDF 2 MB Posted
- Attached to
- HVAC Repair and Remediation Services - LA
- Solicitation number
- 140FC225R0014
About this file
The document is an As-Built Drawing set for Office Building Fungal Growth Remediation & HVAC Design at the Sabine National Wildlife Refuge in Bell City, Louisiana, completed by WB Construction, LLC on 08/19/21. The project involved comprehensive remediation and renovation of the facility's mechanical and electrical systems, including complete removal and replacement of existing HVAC equipment, ductwork, ceiling tiles, lighting fixtures, and electrical components. Key modifications included installing a new heat pump on the porch, replacing the air handling unit (AHU-1) with humidity control, installing new exhaust fans, updating outside air ductwork, and implementing new electrical fixtures with emergency backup capabilities.
The drawing set details specific technical requirements, including installation of volume dampers, external refrigerant piping with aluminum jackets, new ceiling grids and tiles, and comprehensive insulation improvements. The color scheme for the renovated building includes Sherwin Williams colors such as SW 6156 Ramie for Hardi Plank walls, SW 8028 Scrim for interior walls, and SW 6119 Antique White for interior door frames and trim. The project was executed under Contract Number 140F0420C0035 for the U.S. Fish and Wildlife Service, with a focus on addressing fungal growth, improving HVAC system efficiency, and updating the facility's electrical infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI2_after_Q_A_0007.docx | DOCX document | |
| Sol_140FC225R0014_Amd_0007.pdf | ||
| Sol_140FC225R0014_Amd_0006.pdf | ||
| Sol_140FC225R0014_Amd_0005.pdf | ||
| B09_Amd_5_Q_A_0005.pdf | ||
| Sol_140FC225R0014_Amd_0004.pdf | ||
| Sol_140FC225R0014_Amd_0003.pdf | ||
| B09_Amd2_image_0002.png | PNG image | |
| Sol_140FC225R0014_Amd_0002.pdf | ||
| Sol_140FC225R0014_Amd_0001.pdf | ||
| B08_SOW.pdf | ||
| Sol_140FC225R0014.pdf | ||
| Past_Performance_Survey.doc | DOC document | |
| Wages.pdf | ||
| B08_Bid_Shedule.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OFFICE BUILDING FUNGAL
GROWTH REMEDIATION & HVAC
DESIGN
SABINE NATIONAL
WILDLIFE REFUGE
BELL CITY, LOUISIANA
PN: 2019322892 / 2019322891
WB Construction, LLC.
As-Built Drawings
08/19/21
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text T101 TITLE/COVER SHEET TITLE/COVER SHEET A101 FLOOR PLAN & CEILING PLAN FLOOR PLAN & CEILING PLAN MD101 MECHANICAL DEMOLITION MECHANICAL DEMOLITION M101 MECHANICAL PLAN-HVAC MECHANICAL PLAN-HVAC M201 MECHANICAL SCHEDULES MECHANICAL SCHEDULES M301 MECHANICAL DETAILS MECHANICAL DETAILS E101 ELECTRICAL PLAN ELECTRICAL PLAN
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
TITLE/COVER SHEET
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text T101
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text V
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text G.
AutoCAD SHX Text R
AutoCAD SHX Text J
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text I
OFFICE 1
BREAK ROOM
ARMORY
WOMEN'S RESTROOM
CORRIDOR
MEN'S RESTROOM
IT
OFFICE 3
SUPPLY
OFFICE 2
OPEN OFFICE
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
P O
R C
H
P O
R C
H
UP
UP
OFFICE 1
BREAK ROOM
ARMORY
WOMEN'S RESTROOM
CORRIDOR
MEN'S RESTROOM
IT
OFFICE 3
SUPPLY
OFFICE 2
OPEN OFFICE
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
P O
R C
H
P O
R C
H
CEILING GRID
LIGHT FIXTURE
SMOKE/HEAT DETECTOR
EXISTING FLOOR PLAN1
A101
EXISTING CEILING PLAN2
A101
GENERAL NOTES
A. SEE MOLD SPECIFICATION IN
REGARD TO MOLD
REMEDIATION.
KEYED NOTES
1. REMOVE ALL SUSPENDED
CEILING TILES, GRID,
INSULATION, AND HANGARS
AND DISPOSE OF AS MOLD
WASTE. REMOVE AND
DISPOSE OF ALL LIGHT
FIXTURES AND HVAC
REGISTERS AND GRILLES
(SEE MECHANICAL AND
ELECTRICAL DRAWINGS). ALL
HEAT/SMOKE DETECTORS IN
CEILING SHALL BE CLEANED
AND REINSTALLED IN NEW
CEILING. AFTER MOLD
REMEDIATION, PROVIDE NEW
CEILING TILES, LIGHTS, AND
HVAC.
2. REMOVE GYPSUM BOARD
CEILING AND HEADER FROM
CORRIDOR AND DISPOSE OF
AS MOLD WASTE. PROVIDE
NEW 5/8"
MOISTURE-RESISTANT
GYPSUM BOARD FINISHES
AND PAINT 3 COATS TO
MATCH EXISTING WHITE
COLOR FINISHES.
3. REMOVE, CLEAN, AND
REINSTALL EXISTING ATTIC
ACCESS STAIRS. CLEAN AND
REINSTALL NEW WOOD TRIM
AND PAINT 3 COATS, WHITE
COLOR.
4. EXISTING ROOF IS
SUPPORTED BY WOOD
TRUSSES AT 24" O.C. PROVIDE
RIGID INSULATION BOARD ON
BOTTOM OF WOOD TRUSS
CORD TO SEAL CONDITIONED
SPACES FROM ATTIC. TAPE
ALL JOINTS IN INSULATION AT
WALLS THAT TERMINATE AT
BOTTOM CORD OF WOOD
TRUSSES. PROVIDE
FIBERGLASS INSULATION
CONTINUOUS BETWEEN
TRUSSES OVER ALL
CONDITIONED SPACES
BELOW. SEE DETAIL 3/A101.
LEGEND
EXISTING FINISH SCHEDULE
ROOM NAME FLOOR BASE WALLS
CEILING
MAT'L HEIGHT
TYPICAL INSULATION CEILING DETAIL3
A101
As-Built Drawings 08/19/21
Keyed Note #2: All interior walls, ceilings, & doors painted under this contract per Mod P00001 dated 05/19/21.
Keyed Note #3: Attic stairs replaced with new stairs. Old stairs disposed of properly.
Note: All exterior cement board walls & soffit, columns, doors, & metal handrails doors painted under this contract per Mod P00001 dated 05/19/21.
Note: Metal roof cap replaced and / or repaired under this contract per Mod P00001 dated 05/19/21.
Note: Damaged trim, gutter system, & downspouts were replaced under this contract per Mod P00001 dated 05/19/21.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
EXISTING SMOKE/HEAT DETECTOR (TYP.)
AutoCAD SHX Text
EXISTING LIGHT FIXTURE (TYP.)
AutoCAD SHX Text
BOTTOM OF GYPSUM BOARD HEAD AT 7'-11" ABOVE FLOOR
AutoCAD SHX Text
EXISTING TRUSS CORDS AT 24" O.C.
AutoCAD SHX Text
FIBERGLASS INSULATION (MINIMUM R-30)
AutoCAD SHX Text
RIGID INSULATION (VAPOR BARRIER)
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING
AutoCAD SHX Text
CEILING SUPPORT WIRES
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
OFFICE 1
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
OFFICE 2
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
OFFICE 3
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
BREAK ROOM
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
ARMORY
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
P-GB
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
P-GB
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
P-GB
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
P-GB
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text
IT
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CLOSET 1
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CLOSET 2
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CLOSET 3
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CLOSET 4
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text
CLOSET 5
AutoCAD SHX Text
TILE
AutoCAD SHX Text
TILE
AutoCAD SHX Text
P-GB
AutoCAD SHX Text
ACT
AutoCAD SHX Text 7'-11"
AutoCAD SHX Text LEGEND: ACT 2'x2' SUSPENDED ACOUSTICAL CEILING TILE 2'x2' SUSPENDED ACOUSTICAL CEILING TILE P-GB PAINTED GYPSUM BOARDPAINTED GYPSUM BOARD
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 10'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 6'
AutoCAD SHX Text 1'
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 8"
AutoCAD SHX Text 2'
AutoCAD SHX Text 1'
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
FLOOR PLAN & CEILING PLAN
AutoCAD SHX Text A101
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text V
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text G.
AutoCAD SHX Text R
AutoCAD SHX Text J
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text L
SABINE NWR
OFFICE BUILDING FUNGAL GROWTH REMEDIATION & HVAC DESIGN
CONTRACT NUMBER 140F0420C0035
FINISH SCHEDULE – OFFICE BUILDING
1. Exterior
a. Doric Columns Sherwin Williams Color Match – Existing Exterior Doors
b. Trim Sherwin Williams Color Match – Existing Exterior Doors
c. Hardi Plank Walls Sherwin Williams SW 6156 – Ramie
d. PEMB Trim Alabama Steel Supply Inc. Evergreen
2. Doors
a. Interior Door / Frame Sherwin Williams SW-6119 – Antique White
b. Exterior Door / Frame Sherwin Williams Color Match – Existing Exterior Doors
3. Interior
a. Walls Sherwin Williams SW 8028 – Scrim
b. Trim Sherwin Williams SW 6119 – Antique White
UP
UP
DEMOLITION PLAN - HVAC1
MD101
GENERAL NOTES
A. EXISTING MECHANICAL
EQUIPMENT, DUCTWORK,
PIPING, INSULATION,
SUPPORTS, AIR TERMINALS
AND ALL APPURTENANCES
SHALL BE ENTIRELY
REMOVED.
KEYED NOTES
1. REMOVE EXISTING SPLIT
SYSTEM CONDENSING UNIT
AND AHU COMPLETE. REMOVE
ALL REFRIGERANT PIPING
FROM CONDENSING UNIT TO
AHU. EXISTING CONDENSATE
DRAIN PIPING SHALL BE
RE-USED FOR CONNECTION TO
NEW EQUIPMENT.
2. REMOVE EXISTING TOILET
EXHAUST FAN COMPLETE.
3. REMOVE EXISTING DUCTWORK
TO EXHAUST LOUVER.
EXISTING LOUVER SHALL
REMAIN IN PLACE FOR
CONNECTION TO NEW WORK.
4. REMOVE EXISTING OUTSIDE
AIR DUCTWORK TO SIDEWALL
INTAKE LOUVER. INTAKE
LOUVER SHALL REMAIN FOR
CONNECTION TO NEW
DUCTWORK.
5. REMOVE EXISTING
WALL-MOUNTED ATTIC
EXHAUST FAN. EXISTING
OPENING TO BE RE-USED FOR
NEW EQUIPMENT.
As-Built Drawings 08/19/21
AutoCAD SHX Text
EXISTING CEILING DIFFUSER (TYP.)
AutoCAD SHX Text
EXISTING RETURN AIR GRILLE (TYP.)
AutoCAD SHX Text
EXISTING DUCTWORK (TYP.)
AutoCAD SHX Text
EXISTING WALL LOUVER
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
MECHANICAL DEMOLITION
AutoCAD SHX Text
MD101
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 10'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 6'
AutoCAD SHX Text 1'
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
PROFESSIONAL ENGINEER
DAVID R. LEARD LICENSE No. 33809
MECHANICAL PLAN - HVAC1
M101
GENERAL NOTES
A. INSTALL VOLUME DAMPERS
AT TAKEOFF TO
DIFFUSER/GRILLE NEAR
TRUNK MAIN FOR ALL
SUPPLY, RETURN AND
EXHAUST.
B. EXISTING ELECTRICAL
SERVICE FOR ALL
DEMOLISHED MECHANICAL
EQUIPMENT SHALL BE
RE-USED FOR CONNECTION
TO NEW EQUIPMENT.
CONTRACTOR SHALL FIELD
VERIFY ELECTRICAL
REQUIREMENTS FOR ALL NEW
EQUIPMENT PRIOR TO
INSTALLATION.
KEYED NOTES
1. INSTALL NEW HEAT PUMP ON
PORCH. PROVIDE WITH
ANCHORS/SUPPORTS TO MEET
MIAMI-DADE COUNTY
HURRICANE WIND RATINGS.
PROVIDE EXTERIOR MOUNTED
REFRIGERANT PIPING WITH AN
ALUMINUM JACKET.
2. INSTALL AHU-1. PROVIDE
HUMIDITY SENSOR IN RETURN
AIR DUCTWORK TO CONTROL
HUMIDITY TO 50%RH (PLUS OR
MINUS 5%). ROUTE
REFRIGERANT PIPING UP INTO
ATTIC SPACE AND DOWN TO
HEAT PUMP OUTSIDE. CONNECT
UNIT TO EXISTING
CONDENSATE PIPING. PROVIDE
WITH TOUCH-SCREEN
PROGRAMMABLE THERMOSTAT.
3. INSTALL NEW EXHAUST FAN IN
CEILING. ROUTE EXHAUST
DUCTWORK AS REQUIRED TO
EXISTING EXHAUST LOUVER.
4. CONNECT NEW OUTSIDE AIR
DUCT TO RETURN DUCT AT
AHU-1.
5. INSTALL NEW ATTIC EXHAUST
FAN. CONNECT TO EXISTING
ATTIC VENT LOUVER.
6. CONNECT NEW OUTSIDE AIR
DUCTWORK TO EXISTING
LOUVER.
7. PROVIDE DUCTWORK 90°
ELBOW WITH TURNING VANES.
As-Built Drawings 08/19/21
AutoCAD SHX Text
CD-1 150 CFM
AutoCAD SHX Text
CD-1 150 CFM
AutoCAD SHX Text
CD-1 365 CFM
AutoCAD SHX Text
CD-1 365 CFM
AutoCAD SHX Text
CD-1 210 CFM
AutoCAD SHX Text
CD-1 135 CFM
AutoCAD SHX Text
CD-1 65 CFM
AutoCAD SHX Text
CD-1 70 CFM
AutoCAD SHX Text
CD-1 70 CFM
AutoCAD SHX Text
CD-1 60 CFM
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
RAG-1
AutoCAD SHX Text
HP-1
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
RAG-1
AutoCAD SHX Text
RAG-1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
MECHANICAL PLAN-HVAC
AutoCAD SHX Text M101
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 10'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 6'
AutoCAD SHX Text 1'
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
PROFESSIONAL ENGINEER
As-Built Drawings 08/19/21
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
RAG-1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
TYPE
AutoCAD SHX Text X
AutoCAD SHX Text
USE
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
MTG
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
NECK
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
MAX FPM
AutoCAD SHX Text
MAX PD
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
PATTERN
AutoCAD SHX Text
OFFWHITE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text 24"x24"
AutoCAD SHX Text
AutoCAD SHX Text .07"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SEE NOTES
AutoCAD SHX Text NOTES: 1. SUBMIT FINISH/FRAME STYLE OFF ALL DEVICES FOR REVIEW. PROVIDE FRAME TYPE TO MATCH CEILING, I.E. LAY-IN OR HARD SUBMIT FINISH/FRAME STYLE OFF ALL DEVICES FOR REVIEW. PROVIDE FRAME TYPE TO MATCH CEILING, I.E. LAY-IN OR HARD CEILING. 2. NECK SIZE OF EACH GRILLE, REGISTER AND DIFFUSER SHALL BE THE SAME AS THE DUCTWORK IT IS CONNECTED TO. NECK SIZE OF EACH GRILLE, REGISTER AND DIFFUSER SHALL BE THE SAME AS THE DUCTWORK IT IS CONNECTED TO. 3. ALUMINUM CONSTRUCTION. ALUMINUM CONSTRUCTION. 4. EQUIPMENT SHALL COMPLY WITH "BUY AMERICAN ACT".EQUIPMENT SHALL COMPLY WITH "BUY AMERICAN ACT".
AutoCAD SHX Text
LOUVERED RETURN GRILLE
AutoCAD SHX Text
CD-1
AutoCAD SHX Text
GRILLE, REGISTER AND DIFFUSER SCHEDULE
AutoCAD SHX Text X
AutoCAD SHX Text
OFFWHITE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
AutoCAD SHX Text .07"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SEE NOTES
AutoCAD SHX Text
4-WAY CEILING DIFFUSER
AutoCAD SHX Text NOTES: 1. PROVIDE AND INSTALL REFRIGERANT SUPPLY AND RETURN LINES PER MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. PROVIDE AND INSTALL REFRIGERANT SUPPLY AND RETURN LINES PER MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. 2. CONTRACTOR/UNIT MANUFACTURER SHALL BE RESPONSIBLE FOR DETERMINING REQUIRED SPECIALTIES (STRAPS, ETC.) FOR CONTRACTOR/UNIT MANUFACTURER SHALL BE RESPONSIBLE FOR DETERMINING REQUIRED SPECIALTIES (STRAPS, ETC.) FOR COMPLETE OPERATIONAL SYSTEM. 3. PROVIDE ANTI-SHORT CYCLE TIMER. PROVIDE ANTI-SHORT CYCLE TIMER. 4. PROVIDE HIGH AND LOW PRESSURE SWITCHES AND LOW AMBIENT CONTROLS. PROVIDE HIGH AND LOW PRESSURE SWITCHES AND LOW AMBIENT CONTROLS. 5. PROVIDE MATCHING EVAPORATOR COIL ON AHU. PROVIDE MATCHING EVAPORATOR COIL ON AHU. 6. ALL CAPACITIES ARE NET VALUES. ALL CAPACITIES ARE NET VALUES. 7. PROVIDE AND INSTALL FIELD-INSTALLED DEHUMIDIFICATION SYSTEM. EACH SPLIT SYSTEM TO HAVE DEHUMIDIFICATION COIL. PROVIDE AND INSTALL FIELD-INSTALLED DEHUMIDIFICATION SYSTEM. EACH SPLIT SYSTEM TO HAVE DEHUMIDIFICATION COIL. 8. PROVIDE WITH ASTM B117 5,000 HOUR SALT SPRAY TEST RATED COATING. PROVIDE WITH ASTM B117 5,000 HOUR SALT SPRAY TEST RATED COATING. 9. PROVIDE WITH GALVANIZED STEEL CABINET. PROVIDE WITH GALVANIZED STEEL CABINET. 10. EQUIPMENT SHALL COMPLY TO "BUY AMERICAN ACT". EQUIPMENT SHALL COMPLY TO "BUY AMERICAN ACT".
AutoCAD SHX Text
SYSTEM TYPE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
COOLING OUTDOOR AMBIENT TEMP. (F)
AutoCAD SHX Text
COMPRESSOR QUANTITY/TYPE
AutoCAD SHX Text
REFRIGERANT TYPE
AutoCAD SHX Text
V/PH/HZ
AutoCAD SHX Text
RATED CAPACITY (BTUH)
AutoCAD SHX Text
WEIGHT (LB)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SPLIT SYSTEM HEAT PUMP SCHEDULE
AutoCAD SHX Text
MCA MOCP
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
NOMINAL SIZE
AutoCAD SHX Text
HP-1
AutoCAD SHX Text
HEAT PUMP WITH INVERTER COMPRESSOR
AutoCAD SHX Text
5 TON
AutoCAD SHX Text 95°
AutoCAD SHX Text 208/1/60
AutoCAD SHX Text 32.9
AutoCAD SHX Text
AutoCAD SHX Text 57,900
AutoCAD SHX Text R-410-A
AutoCAD SHX Text
(1)/INVERTER
AutoCAD SHX Text
AutoCAD SHX Text
ARI SEER RATING
AutoCAD SHX Text
AutoCAD SHX Text NOTES: 1. HORIZONTAL MOUNTED AIR HANDLING UNIT. HORIZONTAL MOUNTED AIR HANDLING UNIT. 2. PROVIDE 1" THROWAWAY FILTERS, 65% MERV-11. PROVIDE 1" THROWAWAY FILTERS, 65% MERV-11. 3. PROVIDE SINGLE POINT CONNECTION WITH FACTORY INSTALLED DISCONNECT. PROVIDE SINGLE POINT CONNECTION WITH FACTORY INSTALLED DISCONNECT. 4. PROVIDE INTERNAL VIBRATION ISOLATION. PROVIDE INTERNAL VIBRATION ISOLATION. 5. STAINLESS STEEL IAQ DRAIN PAN. STAINLESS STEEL IAQ DRAIN PAN. 6. PROVIDE INTEGRAL FACTORY INSTALLED AND WIRED CONTROLS, FAN CONTACTOR, LOW VOLTAGE TRANSFORMER, AND CONTROL WIRING TERMINAL STRIP. PROVIDE INTEGRAL FACTORY INSTALLED AND WIRED CONTROLS, FAN CONTACTOR, LOW VOLTAGE TRANSFORMER, AND CONTROL WIRING TERMINAL STRIP. 7. PROVIDE AIR HANDLING UNITS WITH ECM DRIVE MOTORS. PROVIDE AIR HANDLING UNITS WITH ECM DRIVE MOTORS. 8. PROVIDE 0-10 VDC SIGNAL BUILT INTO CONTROL PANEL TO UNITS TO MODULATE OUTSIDE AIR DAMPER ACTUATOR. PROVIDE 0-10 VDC SIGNAL BUILT INTO CONTROL PANEL TO UNITS TO MODULATE OUTSIDE AIR DAMPER ACTUATOR. 9. MAINTAIN MANUFACTURER'S RECOMMENDED DISTANCE FOR MAINTENANCE AND CLEARANCE TO COMBUSTIBLES. MAINTAIN MANUFACTURER'S RECOMMENDED DISTANCE FOR MAINTENANCE AND CLEARANCE TO COMBUSTIBLES. 10. COORDINATE CONDENSATE DRAIN TRAP REQUIREMENTS WITH AHU MANUFACTURER. COORDINATE CONDENSATE DRAIN TRAP REQUIREMENTS WITH AHU MANUFACTURER. 11. PROVIDE VARIABLE SPEED DRIVE FANS FOR LOW & HIGH SPEED FAN OPERATION. PROVIDE VARIABLE SPEED DRIVE FANS FOR LOW & HIGH SPEED FAN OPERATION. 9. EQUIPMENT SHALL COMPLY TO "BUY AMERICAN ACT". EQUIPMENT SHALL COMPLY TO "BUY AMERICAN ACT".
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
WEIGHT (LB)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
AIR HANDLING UNIT SCHEDULE
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
AutoCAD SHX Text
SEE NOTES
AutoCAD SHX Text
SUPPLY CFM
AutoCAD SHX Text
O/A CFM
AutoCAD SHX Text
FAN SECTION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1.0
AutoCAD SHX Text
ESP IN WG
AutoCAD SHX Text
DIRECT
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
EDB/EWB °F
AutoCAD SHX Text
LDB/LWB °F
AutoCAD SHX Text
COOLING
AutoCAD SHX Text 80/67
AutoCAD SHX Text 55/54
AutoCAD SHX Text 60,000
AutoCAD SHX Text
TOTAL CAPACITY BTUH
AutoCAD SHX Text V/P/H
AutoCAD SHX Text
FAN H.P.
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 208/1/60
AutoCAD SHX Text 1.0
AutoCAD SHX Text 8.6
AutoCAD SHX Text
MCA
AutoCAD SHX Text
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
AREA SERVED
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
FAN DATA
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SEE NOTES 2
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
SPEED
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text 0.21
AutoCAD SHX Text
IN. WTR.
AutoCAD SHX Text
AutoCAD SHX Text
RPM
AutoCAD SHX Text
AIR
AutoCAD SHX Text
STATIC
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
FAN
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text 0.7
AutoCAD SHX Text
AMP
AutoCAD SHX Text
AutoCAD SHX Text
SINGLE
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
DIRECT DRIVE
AutoCAD SHX Text NOTES: 1. ALUMINUM HOUSING WITH CORROSION-RESISTANT FASTENERS AND ALUMINUM HOUSING WITH CORROSION-RESISTANT FASTENERS AND BIRD SCREEN. 2. BASIS OF DESIGN: GREENHECK MODEL SP-B90. BASIS OF DESIGN: GREENHECK MODEL SP-B90. 3. BASIS OF DESIGN: BROAN MODEL 35316. BASIS OF DESIGN: BROAN MODEL 35316. 4. EQUIPMENT SHALL COMPLY WITH THE "BUY AMERICAN ACT".EQUIPMENT SHALL COMPLY WITH THE "BUY AMERICAN ACT".
AutoCAD SHX Text
EXHAUST FAN SCHEDULE
AutoCAD SHX Text
MENS RESTROOM
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
RESTROOM EXHAUST FAN
AutoCAD SHX Text
SEE NOTES
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
WOMENS RESTROOM
AutoCAD SHX Text
DIRECT DRIVE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
RESTROOM EXHAUST FAN
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
GABLE-MOUNTED ATTIC VENTILATOR
AutoCAD SHX Text
DIRECT DRIVE
AutoCAD SHX Text 1,420
AutoCAD SHX Text
AutoCAD SHX Text 1,160
AutoCAD SHX Text 5.5
AutoCAD SHX Text
SEE NOTES 1,2
AutoCAD SHX Text
AutoCAD SHX Text
SINGLE
AutoCAD SHX Text 60,000
AutoCAD SHX Text
TOTAL CAPACITY BTUH
AutoCAD SHX Text
1. ALL DUCTWORK ASSOCIATED WITH THE MECHANICAL SYSTEMS SHALL BE INSTALLED AND SECURED PER ALL DUCTWORK ASSOCIATED WITH THE MECHANICAL SYSTEMS SHALL BE INSTALLED AND SECURED PER APPLICABLE BUILDING CODES. 2. MECHANICAL CONTRACTOR SHALL COORDINATE AIR DISTRIBUTION DEVICE LAYOUT WITH ARCHITECTURAL MECHANICAL CONTRACTOR SHALL COORDINATE AIR DISTRIBUTION DEVICE LAYOUT WITH ARCHITECTURAL REFLECTED CEILING PLANS. 3. MECHANICAL CONTRACTOR SHALL INSTALL VOLUME DAMPERS IN AIR DUCTS TO NEW SUPPLY, RETURN, AND MECHANICAL CONTRACTOR SHALL INSTALL VOLUME DAMPERS IN AIR DUCTS TO NEW SUPPLY, RETURN, AND EXHAUST GRILLES. VOLUME DAMPERS SHALL BE LOCATED FOR ACCESS FROM LAY-IN CEILING OR ACCESS DOORS, WHERE GYP CEILINGS ARE INSTALLED. 4. THERMOSTAT HEIGHT SHALL BE 4'-0" ABOVE FINISHED FLOOR, AND SHALL BE ALIGNED WITH LIGHT SWITCH THERMOSTAT HEIGHT SHALL BE 4'-0" ABOVE FINISHED FLOOR, AND SHALL BE ALIGNED WITH LIGHT SWITCH WHERE SHOWN AT THE SAME LOCATION. 5. MANUAL BALANCING DAMPERS TO BE LOCATED WHERE OPERATORS ARE ACCESSIBLE. MANUAL BALANCING DAMPERS TO BE LOCATED WHERE OPERATORS ARE ACCESSIBLE. 6. DUCT DIMENSIONS SHOWN FOR RECTANGULAR DUCTWORK ARE SHEET METAL SIZES. DIMENSION SHOWN FOR DUCT DIMENSIONS SHOWN FOR RECTANGULAR DUCTWORK ARE SHEET METAL SIZES. DIMENSION SHOWN FOR ROUND DUCTWORK ARE NET INSIDE DIMENSION. 7. LOW PRESSURE DUCT RUNOUTS FROM RECTANGULAR DUCTS TO DIFFUSERS SHALL BE FLEXIBLE ROUND AND LOW PRESSURE DUCT RUNOUTS FROM RECTANGULAR DUCTS TO DIFFUSERS SHALL BE FLEXIBLE ROUND AND 4'-0" MAXIMUM LENGTH, AND SHALL HAVE SAME DIAMETER AS DIFFUSER NECK UNLESS OTHERWISE NOTED. 8. PROVIDE FLEXIBLE CONNECTIONS TO DUCTWORK AT ALL INDOOR UNITS, EF'S, ETC. PROVIDE FLEXIBLE CONNECTIONS TO DUCTWORK AT ALL INDOOR UNITS, EF'S, ETC. 9. COORDINATE EXACT LOCATION OF ALL PIPING AND DUCT PENETRATIONS OF WALLS WITH STRUCTURAL COORDINATE EXACT LOCATION OF ALL PIPING AND DUCT PENETRATIONS OF WALLS WITH STRUCTURAL BRACING. 10. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING AND LIGHTING PLANS FOR FINAL LOCATION OF AIR COORDINATE WITH ARCHITECTURAL REFLECTED CEILING AND LIGHTING PLANS FOR FINAL LOCATION OF AIR DISTRIBUTION DEVICES AND EQUIPMENT MOUNTED IN CEILING. 11. WHERE PIPING IS ROUTED THROUGH EXTERIOR WALL OF BUILDING, PROVIDE "LINK SEAL" AND SLEEVES FOR WHERE PIPING IS ROUTED THROUGH EXTERIOR WALL OF BUILDING, PROVIDE "LINK SEAL" AND SLEEVES FOR PENETRATION OF WALL.
AutoCAD SHX Text
HVAC GENERAL NOTES
AutoCAD SHX Text 24"x24"
AutoCAD SHX Text
SEE NOTES 2
AutoCAD SHX Text
AutoCAD SHX Text 0.21
AutoCAD SHX Text
AutoCAD SHX Text 0.7
AutoCAD SHX Text
AutoCAD SHX Text
SINGLE
AutoCAD SHX Text 1,420
AutoCAD SHX Text
AutoCAD SHX Text 1,160
AutoCAD SHX Text 5.5
AutoCAD SHX Text
SEE NOTES 1,2
AutoCAD SHX Text
AutoCAD SHX Text
SINGLE
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
GABLE-MOUNTED ATTIC VENTILATOR
AutoCAD SHX Text
DIRECT DRIVE
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
MECHANICAL SCHEDULES
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text M201
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
PROFESSIONAL ENGINEER
NOTE: SPIN-IN FITTINGS WITH SCOOPS ARE NOT ACCEPTABLE
NEOPRENE GASKET
VOLUME DAMPER W/
LOCKING QUADRANT
PROVIDE STAND-OFF DAMPER
BRACKET ON EXT. INSULATED
DUCTS
SET PLANS FOR DIFFUSER
RUN-OUT DUCT SIZES
SEE SPECS AND NOTES FOR
INSULATION REQUIREMENTS
45 DEG TAKEOFF W/
DAMPER
NOTES:
1. RETURN & EXHAUST SIMILAR
WITH DIRECTION OF FLOW
ARROWS REVERSED.
2. ALL DUCTS TO BE GALVANIZED
SHEET METAL. SEE PLANS FOR
SIZE.
3. THIS DETAIL IS APPLICABLE TO
SUPPLY, RETURN AND EXHAUST
BRANCH CONNECTIONS OF
THIS CONFIGURATION.
DIRECTION OF AIR
FOR SUPPLY
DIRECTION OF AIR
FOR RETURN
NOTES:
1. RIGID ROUND DUCTS TO BE
GALVANIZED SM, FIELD FABRICATED
OR PRE-FAB SPIRAL DUCT. SEE
PLANS FOR SIZE.
2. DETAIL IS APPLICABLE TO SUPPLY
AND RETURN BRANCH
CONNECTIONS.
TURNING VANES,
TYPICAL TURNS 45°
DEGREES OR LARGER
NUMBER AND
CONFIGURATION OF
VANES PER SMACNA
STANDARDS.
TOP RUNNER NOT SHOWN FOR
CLARITY.
DOUBLE SIDED TURNING VANES
RUNNER
INSTALL VANES TANGENT TO
AIRSTREAM
LOW CLEARANCE OR FIRE DAMPER INSTALLATIONTYPICAL ELBOW INSTALLATION
AIR FLOW
AIR FLOW
M
I N
D
D
NOTE 8
D
WORM GEAR
CLAMP (TYP)
2" WIDE SHEET
METAL STRAP
TYPICAL ELBOW INSTALLATION
AIR FLOW
AIR FLOW
LOW CLEARANCE OR FIRE DAMPER INSTALLATION
NOTE 2
M
I N
D o r
H
NOTE 8
D o r
H
NOTE 6
NOTE 3
NOTE 2
CEILING
NOTE 4
OVERHEAD
OBSTRUCTION
NOTE 5
NOTE 1
CEILING
NOTE 4
NOTE 7
NOTE 2
CEILING
NOTE 4
NOTE 3
NOTE 1
MINIMUM RAD
EQUALS D
NOTE 1
NOTE 7
NOTE 4
NOTE 2
CEILING
OVERHEAD OBSTRUCTION
NOTE 5
WORM GEAR CLAMP
NOTE 6
NOTE 7
MINIMUM RAD
EQUALS D
NOTES:
1. INSULATED FLEXIBLE DUCT. MAXIMUM FLEX DUCT LENGTH IS 5 FEET IN ITS INSTALLED CONDITION.
2. INSULATE TOP OF AIR DEVICE (TYPICAL ALL SUPPLY DIFFUSERS). SEAL EDGES WITH VAPOR BARRIER TAPE.
3. ELIMINATE SQUARE TO ROUND ADAPTER IF DEVICE HAS ROUND NECK. TRANSITION AS REQUIRED.
4. SEE AIR DEVICE SCHEDULES FOR ADDITIONAL AIR DEVICE REQUIREMENTS.
5. INTERNALLY LINE PLENUM WITH 1" DUCT LINER FOR SOUND ATTENUATION. CLEAR INSIDE DIMENSION TO
MATCH NECK SIZE.
6. EXTERNALLY INSULATE ALL ROUND DUCTS. SEE NOTES AND SPECIFICATIONS.
7. INSTALL EQUALIZING GRID OR PERFORATED PANEL AT CONNECTION TO DIFFUSER.
8. PROVIDE MINIMUM OF ONE DUCT DIAMETER STRAIGHT DUCT BEFORE THE DIFFUSER PLENUM CONNECTION.
9. DO NOT USE FLEX DUCTS FOR 90 DEGREE ELBOWS OR FOR DOWNTURN TO AIR DEVICES.
NOTES:
1. GALVANIZED SHEET METAL RIGID ROUND OR RECTANGULAR DUCT AS INDICATED ON FLOOR PLANS.
2. INSULATE TOP OF AIR DEVICE UNLESS INSTALLED IN RETURN AIR PLENUM. SEAL EDGES WITH VAPOR
BARRIER TAPE.
3. ELIMINATE SQUARE TO ROUND ADAPTER IF DEVICE HAS ROUND NECK. TRANSITION AS REQUIRED.
4. SEE AIR DEVICE SCHEDULES FOR AIR DEVICES REQUIRED TO HAVE OPPOSED BLADE DAMPERS.
5. INTERNALLY LINE PLENUM WITH 1" DUCT LINER FOR SOUND ATTENUATION. CLEAR INSIDE DIMENSION TO
MATCH NECK SIZE.
6. EXTERNALLY INSULATE ALL ROUND DUCTS. SEE NOTES AND SPECS.
7. PROVIDE FILTER WHEN REQUIRED BY AIR DEVICE SCHEDULES.
9. DO NOT USE FLEX DUCTS FOR 90 DEGREE ELBOWS OR FOR DOWNTURN TO AIR DEVICES.
HIGH EFFICIENCY 45 DEG TAKEOFF
LOCKABLE DAMPER (INTEGRAL TO TAKEOFF). MOUNT
WITH HANDLE IN ACCESSIBLE POSITION.
EXTERNALLY INSULATED RIGID GALVANIZED
SHEET METAL BRANCH DUCT
WORM GEAR MECHANICAL
FASTENERS
AIR DEVICE
INSULATED FLEX DUCT
3'-0" MAX LENGTH
SEE BRANCH TAKEOFF DETAIL A THIS
SHEET. SEAL @ CONNECTION TO MAIN
SUPPLY DUCT
EXTERNALLY INSULATED
SUPPLY DUCT OR SUPPLY
AIR PLENUM
A
R
F
L O
W
FOR TYPICAL ELBOW DOWNTURN
APPLICATION, USE RIGID
GALVANIZED SHEET METAL ELBOW.
SEE CEILING SUPPLY AIR DIFFUSER
DETAIL FOR LOW CLEARANCE
APPLICATIONS AND ADDITIONAL
INFORMATION.
RIGID GALVANIZED
SHEET METAL
ELBOW
TO AIR DEVICE
RIGID GALVANIZED
SHEET METAL ELBOW
TO AIR DEVICE
D = DIAMETER
D = DIAMETER
H = HEIGHT
CLOSE OPENINGS
AT CORNERS
W
SIDE OF
MAIN DUCT
A
I
R
F
L
O
W
SEE PLANS FOR
TAKE-OFF SIZES
VOLUME DAMPER
W/LOCKING QUADRANT
PROVIDE STAND-OFF
DAMPER BRACKET ON
EXT. INSULATED DUCTS
45°
EQUAL TO 1/4 WIDTH
(4" MINIMUM)
N
O
T
E
BRANCH DUCT TAKEOFF DETAIL A1
M300
BRANCH DUCT TAKEOFF DETAIL B2
M300
TURNING VANE DETAIL3
M300
CEILING RETURN GRILLE DETAIL4
M300
CEILING SUPPLY DIFFUSER DETAIL5
M300
DIFFUSER TAKEOFF DETAIL6
M300
As-Built Drawings 08/19/21
AutoCAD SHX Text
REQUIRED WHERE DUCT HEIGHT IS 24" OR GREATER.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text M301
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
PROFESSIONAL ENGINEER
OFFICE 1
BREAK ROOM
ARMORY
WOMEN'S RESTROOM
CORRIDOR
MEN'S RESTROOM
IT
OFFICE 3
SUPPLY
OFFICE 2
OPEN OFFICE
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
C L O
S E
T
P O
R C
H
P O
R C
H
2X4 TROFFER
SURFACE
SMOKE/HEAT DETECTOR
MOUNT FIXTURE
2X2 TROFFER
ELECTRICAL PLAN1
E101
GENERAL NOTES
A. EXISTING LIGHT FIXTURES
SHALL BE ENTIRELY
REMOVED.
B. FIXTURES DENOTED "-E" TO
HAVE INTEGRAL BATTERY
POWERED EMERGENCY
BACKUP WITH SELF CHECK
CIRCUITRY.
KEYED NOTES
1. REMOVE, CLEAN AND RETAIN
ALL SMOKE DETECTORS.
TERMINATE BARE
CONDUCTORS WITH WIRE NUTS
AND PROTECT CIRCUITS.
REINSTALL AFTER
REMEDIATION AND CEILING
INSTALLATION.
2. REMOVE ALL INTERIOR
LIGHTING FIXTURES.
TERMINATE BARE
CONDUCTORS WITH WIRE NUTS
AND PROTECT CIRCUITS.
PROVIDE AND INSTALL NEW
FIXTURES PER LIGHTING
SCHEDULE.
3. DISCONNECT MECHANICAL
EQUIPMENT. TERMINATE
CONDUCTORS WITH WIRE NUTS
AND PROTECT CIRCUITS.
WEATHERPROOF EXTERIOR
CIRCUITS. CONNET NEW
MECHANICAL EQUIPMENT.
COORDINATE EQUIPMENT
BREAKERS, FUSES AND WIRE
SIZING WITH MECHANICAL
CONTRACTOR.
4. AIR HANDLER LOCATED ON
EQUIPMENT MEZZANINE IN
ATTIC SPACE.
5. CONDENSING UNIT LOCATED
ON EXTERIOR PORCH.
6. EXHAUST FAN LOCATED IN
ATTIC SPACE.
LEGEND
As-Built Drawings 08/19/21
Note: All exterior soffit / porch lights and wall packs were replaced under this contract per SOW for Modification P0001 dated 05/19/21.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
EXISTING SMOKE/HEAT DETECTOR (TYP.)
AutoCAD SHX Text
EXISTING LIGHT FIXTURE (TYP.)
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 10'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 6'
AutoCAD SHX Text 1'
AutoCAD SHX Text
LIGHT FIXTURE SCHEDULE (BASIS OF DESIGN)
AutoCAD SHX Text
INDEX
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text Article name
AutoCAD SHX Text
MODEL NUMBER
AutoCAD SHX Text
LUMINUS FLUX
AutoCAD SHX Text
POWER
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text A
AutoCAD SHX Text Lithonia Lighting
AutoCAD SHX Text 2X4 Direct Indirect LED Troffer, 3000 lumen, HE version, Perforated Metal Diffuser with Optical Film, 3500K
AutoCAD SHX Text
2AVL4 30LHE MDR LP835
AutoCAD SHX Text 3094 Lm
AutoCAD SHX Text
30.4 W
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text Lithonia Lighting
AutoCAD SHX Text 2X4 Direct Indirect LED Troffer, 4000 lumen, HE version, Perforated Metal Diffuser with Optical Film, 3500K
AutoCAD SHX Text
2AVL4 40LHE MDR LP835
AutoCAD SHX Text 4080 lm
AutoCAD SHX Text 41 W
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text Lithonia Lighting
AutoCAD SHX Text
STL4 4' 2000 NOMINAL LUMENS 4000K
AutoCAD SHX Text
STL4 20L EZ1 LP840
AutoCAD SHX Text 2230 lm
AutoCAD SHX Text 20 W
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text Lithonia Lighting
AutoCAD SHX Text 2X2 Direct Indirect LED Troffer, 2000 lumen, HE version, Perforated Metal Diffuser with Optical Film, 3500K
AutoCAD SHX Text
2AVL2 20LHE MDR LP835
AutoCAD SHX Text 2087 lm
AutoCAD SHX Text
20.4 W
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A-E
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text B-E
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text B-E
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-3
AutoCAD SHX Text A-E
AutoCAD SHX Text A-E
AutoCAD SHX Text A-E
AutoCAD SHX Text B-E
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
AutoCAD SHX Text Johnson M Adams
AutoCAD SHX Text
108 W. MARKET ST., GREENWOOD, MS 38930 (662) 455-4943
AutoCAD SHX Text
THE
AutoCAD SHX Text c
AutoCAD SHX Text P.A.
AutoCAD SHX Text
FIRM
AutoCAD SHX Text
SABINE NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text
BELL_CITY,LA
AutoCAD SHX Text 03/18/2020
AutoCAD SHX Text E101
AutoCAD SHX Text
OFFICE BUILDING FUNGAL GROWTH INSPECTION AND HVAC DESIGN
AutoCAD SHX Text
PROFESSIONAL ENGINEER
AutoCAD SHX Text DAVID R. LEARD LICENSE No. 33809 dvann Rectangle dvann Rectangle dvann Callout New Exterior Wall Pack Light Fixture. Type F dvann Callout New Exterior Wall Pack Light Fixture. Type F dvann Rectangle dvann Callout New Exterior Wall Pack Light Fixture. Type F dvann Rectangle dvann Rectangle dvann Rectangle dvann Callout New Canopy Light Fixtures (Typ. of 3) Type E.
dvann Typewritten Text E dvann Typewritten Text E dvann Typewritten Text E dvann Text Box Type E - Lithonia Lighting - CNY LED P2 40K MVOLT DDB M4 Type F - Lithonia Lighting - TWX3LED ALO 50K MVOLT DDBTXD
| T101 |
| Sheets and Views |
| T101-T101 |
| MD101 |
| Sheets and Views |
| MD101-MD101 |
| A101 |
| Sheets and Views |
| A101 floor plan-A101 |
| M101 |
| Sheets and Views |
| M101-M101 |
| M201 |
| Sheets and Views |
| M201-M201 |
| M301 |
| Sheets and Views |
| M301-M301 |
| E101 |
| Sheets and Views |
| E101-E101 |
File details come from the government source that posted it. Updated .