This document is a network infrastructure diagram and circuit inventory for the National Institutes of Health (NIH) depicting interconnected data centers and facilities across multiple Maryland and Virginia locations. The network consists of eight primary sites: Building 12 and Building 10 in Bethesda, Maryland; Shady Grove in Rockville, Maryland; ATRF (Advanced Technology and Research Facility) in Frederick, Maryland; Building 430 at Fort Detrick, Maryland; Coresite VA1 in Reston, Virginia; and Equinix DC2 in Ashburn, Virginia.
The infrastructure includes twelve active and inactive circuits utilizing multiple connectivity technologies: 100 Gigabit Wave connections, 10x10 Gigabit Wave connections, 4x10 Gigabit connections, dark fiber, and AWS Direct Connect services. Key circuits include 100G CORE connections between ATRF and Shady Grove (circuits 1-2), 4x10G connections between Shady Grove and Bethesda (circuits 3-4), AWS Direct Connect links to production and test environments in Ashburn and Reston (circuits 5-8), a 100G connection between ATRF and Fort Detrick (circuit 10), and 10G laboratory connections between ATRF and Shady Grove (circuits 11-12). Each circuit specifies device names, port assignments, and routing information. The network architecture employs redundancy through multiple route options and separates production and test connectivity to AWS cloud environments.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140D0426Q0575_Amd_0004.pdf | ||
| Sol_140D0426Q0575_Amd_0003.pdf | ||
| Sol_140D0426Q0575_Amd_0002.pdf | ||
| B09_SA_2_Q_A_0002.xlsx | XLSX spreadsheet | |
| B09_SA_1_Q_A_0001.xlsx | XLSX spreadsheet | |
| B09_SA_1_0001.pdf | ||
| B09_SA_1_Attachment_1_-_Contract_Certifications_and_Provisions_0001.pdf | ||
| Sol_140D0426Q0575_Amd_0001.pdf | ||
| B09_SA_1_Quality_Assurance_Surveillance_Plan_0001.pdf | ||
| Sol_140D0426Q0575.pdf | ||
| B08_SOL_Fiber.pdf | ||
| B08_SOL_Attachment_3_-_Appendix_A.pdf | ||
| B08_SOL_Attachment_2_-_VPAT2_5Rev_508_February2025.pdf | ||
| B08_SOL_Attachment_1_-_Contract_Certifications_and_Provisions.pdf | ||
| B08_SOL_Attachment_4_-_Quality_Assurance_Surveillance_Plan.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 12 12 South Dr, Bethesda, MD
Building 10 10 Center Dr, Bethesda, MD
Shady Grove 9609 Medical Center Drive, Rockville, MD
ATRF
8560 Progress Drive, Frederick, MD
Coresite VA1 12100 Sunrise Valley Drive, Reston
Equinix DC2 21715 Filigree Court, Ashburn
Building 430 430 Miller Drive, Fort Detrick, MD
Shelf 1
WDC
Shelf 2
Shelf 1
Shelf 2
Shelf 2Shelf 1
Shelf 2
EDC
Shelf 1
Shelf 2
Shelf 1
Shelf 1Shelf 2
Dark Fiber
Dark Fiber
Dark Fiber Dark Fiber
Dark Fiber
Dark Fiber
Shelf 3 x1
0G bi t W av e x1
0G bi t W av e
0G b W av e
0G b W av e
Number Description Device Port Device Port 1 100G between CORE A VSPs in the ATRF and Shady Grove (long route) FP-8560-E1901-N1-CORE-A Port 1/18 RS-9609-TW202-W84-CORE-A Port 8/5 2 100G between CORE B VSPs in the ATRF and Shady Grove (short route) FP-8560-E1901-N2-CORE-B Port 1/18 RS-9609-TE21-E90-CORE-B Port 8/5 3 4x10G between CORE B VSPs in Shady Grove and Bethesda (long route) RS-9609-TE21-E90-CORE-B Ports 5/2/1-5/2/4 BN-12-CSA1-F57-CORE-B Ports 5/2/1-5/2/4 4 4x10G between CORE A VSPs in Shady Grove and Bethesda (short route) RS-9609-TW202-W84-CORE-A Ports 5/2/1-5/2/4 BN-10-B1N243-4F-CORE-A Ports 5/2/1-5/2/4 5 AWS Direct Connect between the ATRF and Ashburn (Prod) FP-8560-E1901-N4-CE-B Port 0/1 dxcon-ffkofrdo NCI-XCO-IAD18-010 6 AWS Direct Connect between the ATRF and Reston (Test) FP-8560-E1901-N2-CORE-F Port 1/32 dxcon-fgtq75hz NCI-XCO-IAD3-012 7 AWS Direct Connect between Shady Grove and Ashburn (Test) LAB-RS-9609-TE21-E89-CE-A Port 0/1 dxcon-fgqyx6l1 NCI-XCO-IAD18-011 8 AWS Direct Connect between Shady Grove and Reston (Prod) RS-9609-TW202-W81-CE-A Port 0/1 dxcon-fgnhjpwy NCI-XCO-IAD3-013 9 (no longer in use) 10 100G between ATRF SLX CE Router and B430 CIT PE Router FP-8560-E1901-N4-CE-B Port 0/28 FDK-NIH-PE-A1 Hu0/2/0/1 11 10G between Lab CORE A VSPs in the ATRF and Shady Grove (short route) LAB-FP-8560-E1900-WR3-CORE-A Port 1/23 S2-SPINE-A Port 1/23 12 10G between Lab CORE B VSPs in the ATRF and Shady Grove (short route) LAB-FP-8560-E1900-WR3-CORE-B Port 1/23 S2-SPINE-B Port 1/23
KEY
100Gb Wave
Dark Fiber
100Gb Wave
10x10Gb Wave
Bethesda
Building 12 12 South Dr, Bethesda, MD
Building 10 10 Center Dr, Bethesda, MD
Ft Detrick 430 Miller Dr
ATRF
8560 Progress Dr
Shady G rove
9609 M edical Center D r Re st on
Su nr is e Va lle y
D r
As hb ur n
Fi lig re e Ct
2Da rk
F ib er Dark Fiber
Dark Fiber
Dark FiberDark Fiber
10x10Gb Wave
10x10G b W ave
10x10Gb Wave10x10Gb Wave x1
0G b
W av e 100G b W ave
4x10G Active Circuit (color coded and numbered)
10G Active Circuit (color coded and numbered)
10G Inactive Circuit (gray)
100G Active Circuit (color coded and numbered)
Dark Fiber Logical Circuit (100G or 10x10G)