B08_SOL_Attach_C_CAD_Full_Set_0001.pdf
PDF 8 MB Posted
- Attached to
- NICG Physical Access Control System
- Solicitation number
- 140D0424Q0572
About this file
This document appears to be an architectural drawing package related to a federal contract opportunity for an interior renovation project at the National Indian Gaming Commission (NIGC) 9th floor office space. The package includes detailed plans and specifications for the demolition, construction, power/signal, reflected ceiling, and finishes for the approximately 15,072 SF tenant space. Key details include:
The project is located at 550 12th St, SW, Washington, DC and involves an interior renovation of an existing NIGC tenant suite. The architectural, mechanical, electrical, and plumbing designs must comply with various District of Columbia building codes and standards. The scope of work includes MEP-related modifications. The tenant space is located on the 9th floor of a fully sprinklered, 11-story building. The project has a permit and pricing submission date of 01/04/24.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECT:
OTJ ARCHITECTS
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
MEP ENGINEER:
P R
O
JE
C T
N U
M B
E R
/N A
M E
ISSUED FOR:
Date of Submission:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws and regulations of the District of Columbia. I have personally prepared, or directly supervised the development of, the architectural designs included in this application.
01/04/24
PERMIT & PRICING
NATIONAL INDIAN GAMING
COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
NIGC - 9TH FLOOR
INTERIOR RENOVATION
GHT LIMITED CONSULTING ENGINEERS
.0
N
IG
C
T H
F L O
O R
1110 NORTH GLEBE RD., Ste 300
ARLINGTON, VA 22201
P: 703.243.1200
CONTACT: TONY MARTIN
DN UP
#7
#6
#5
#1
#2
#3
#4
F.E.C.
F .E
.C
F.E.C.
F .E
.C
WASHINGTON DC
Name of Jurisdiction: WASHINGTON, DISTRICT OF COLUMBIA
Project Name: NIGC 9TH FLOOR
Building: 2017 DC CONSTRUCTION CODE SUPPLEMENT (DCMR 12A)
2015 INTERNATIONAL BUILDING CODE
2015 DC GREEN CONSTRUCTION CODE (DCMR 12-K)
2015 DC EXISTING BUILDING CODE (DCMR 12-J)
(PRESCRIPTIVE COMPLIANCE METHOD)
Sustainability: 2017 DC GREEN CONSTRUCTION CODE (DCMR 12-K)
2012 INTERNATIONAL GREEN BUILDING CODE
Electrical: 2017 DC ELECTRICAL CODE (DCMR 12-C)
2017 DC ENERGY CONSERVATION CODE (DCMR 12-I)
2013 - ANSI/ASHRAE/IES STANDARD 90.1
2014 NEC - NATIONAL ELECTRICAL CODE
Mechanical: 2017 DC MECHANICAL CODE (DCMR 12-E)
2015 INTERNATIONAL MECHANICAL CODE
Plumbing: 2017 DC PLUMBING CODE (DCMR 12-F)
2015 INTERNATIONAL PLUMBING CODE
Fire: 2017 DC FIRE CODE (DCMR 12-H)
2015 INTERNATIONAL FIRE CODE
Accessibility: 2017 DC CONSTRUCTION CODE (CHAPTER 11 OF DCMR 12-A)
2015 INTERNATIONAL BUILDING CODE
2009 ICC A117.1 - ACCESSIBLE AND USABLE BLDG & FACILITIES
Scope of Work: INTERIOR RENOVATION OF EXISTING TENANT SUITE TO INCLUDE
MEP RELATED MODIFICATIONS. (APPROXIMATELY 15,072 SF )
Building Information:
Use Group of Building: B
Use Group of Tenant: B
Type of Construction (Building): IB
Type of Construction (Tenant): IB
Fire Resistance Rating Requirements: Based Upon the 2017 DC Building Code (2015 IBC) Table 601
Structural Frame:
(Including Columns, Girders, Trusses) 2 HR
Bearing Walls:
Exterior: 2 HR
Interior: 2 HR
Non-Bearing Walls:
Exterior: 1 HR
Interior: 0 HR
Floor Construction :
(Including Supporting Beams & Joists) 2 HR
Roof Construction :
(Including Supporting Beams & Joists) 1.5 HR
High Rise: YES
Height of Stories: 11 STORIES
Building Sprinkler: FULLY SPRINKLERED? YES
Floor Location: 9TH FLOOR
Covered Mall: NO
A1.01
A101
A1.01
1t
101 DOOR TAG
WINDOW TAG
REVISION TAGROOM NAME AND
NUMBER TAG
DETAIL MARK
ELEVATION
SYMBOLS
SECTION MARK
NEW DOOR AND FRAME
NEW LIGHT FIXTURE,
LETTER INDICATES FIXTURE
TYPE
EXISTING LIGHT FIXTURE TO
BE REMOVED
NEW GWB CEILING
EXISTING GWB CEILING
EXISTING CEILING GRID
SYSTEM TO BE REMOVED
EXISTING CEILING GRID
SYSTEM TO REMAIN
ELEVATION MARK
ALIGN
WALL TYPE TAG
FINISH TYPE
TAG
PLAN NOTE
EXISTING DOOR AND
FRAME TO REMAIN
DEMOLISHED/RELOCATED DOOR
AND FRAME
NEW MOVABLE PARTITION. REFER
TO PARTITION TYPES SHEET FOR
ADDITIONAL INFORMATION.
NEW PARTITIONS, REFER TO
PARTITION TYPES SHEET A0.2 FOR
ADDITIONAL INFORMATION
EXISTING PARTITION TO
REMAIN
DEMOLISHED
PARTITION
NEW MILLWORK BASE FOR
FULL HEIGHT CABINETS
NEW MILLWORK SHELVING
OR UPPER CABINETS
DEMOLISHED MILLWORK
DEVICE OR EQUIPMENT.
OTHER DEVICES SHOWN
SIMILARLY
EXISTING DEVICES TO REMAIN.
OTHER DEVICES SHOWN
SIMILARLY.
EXISTING DEVICES TO BE
DEMOLISHED. OTHER DEVICES
SHOWN SIMILARLY.
1i
P
WD1
1 Ref
R e f
1 Ref
R e f
C1
XX
ROOM NAME
DD
SUBFLR SUBFLOOR
SUSP SUSPENSION
SYM SYMMETRY(ICAL)
TB TACKBOARD
TEL TELEPHONE
TV TELEVISION
TPT TEXTURES PAINT
THK THICK(NESS)
THHD THRESHOLD
THRU THROUGH
TBD TO BE DETERMINED
T&G TONGUE & GROOVE
T&B TOP & BOTTOM
TOC TOP OF CURB
TOS TOP OF SLAB
TOS TOP OF STEEL
TOW TOP OF WALL
T TREAD
TRT TREAT(ED)
TYP TYPICAL
UC UNDERCUT
UG UNDERGROUND
UNFIN UNFINISHED
UH UNIT HEATER
UNO/UO
N
UNLESS OTHERWISE NOTED
VAC VACUUM
VR VAPOR RETARDER
VIF VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
V VINYL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VT VINYL TILE
VWB VINYL WALL BASE
VWC VINYL WALL COVERING
WSCT WAINSCOT
WC WATER CLOSET
WH WATER HEATER
WR WATER RESISTANT
WP WATERPROOFING
WT WEIGHT
W WEST
WDW WINDOW
WGL WIRE GLASS
W/ WITH
W/O WITHOUT
WB WOOD BASE
WD WOOD BASE
WPT WORKING POINT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PC PRECAST
PREFAB PREFABRICATE(D)
PREFIN PREFINISHED
PREP PREPARE
PROJ PROJECT
QTY QUANTITY
QT QUARRY TILE
RAD RADIUS
RL RAIN LEADER
RECP RECEPTACLE
REF REFERENCE
REFG REFRIGERATOR
REINF REINFORCE(D)(ING)
REQD REQUIRED
REQMT REQUIREMENT
RES RESILIENT
RET RETURN
RA RETURN AIR
RH RIGHT HAND
R/W RIGHT OF WAY
R RISER
RTU ROOFTOP UNIT
RM ROOM
RO ROUGH OPENING
RB RUBBER BASE
RT RUBBER TILE
SAN SANITARY
SCH SCHEDULE
SHTH SHEATHING
SHT SHEET
SHLVG SHELVING
SC SOLID CORE
SCWD SOLID CORE WOOD DOOR
SAB SOUND ATTENUATION
BLANKET
STC SOUND TRANSMISSION
COEFFICIENT
S SOUTH
SPEC SPECIFICATION
SOF SPRAY FIREPROOFING
SPR SPRINKLER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STOR STORAGE
SD STORM DRAIN
ST STREET
STRUCT STRUCTURAL
LAV LAVATORY
LH LEFT HAND
LT LIGHT
LW LIGHTWEIGHT
LF LINEAR FEET (FOOT)
LKR LOCKER
LVR LOUVER
LBS POUNDS
MACH MACHINE
MFR MANUFACTURER
MB MARKERBOARD
MO MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MTL METAL
M METER(S)
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLDG MOULDING
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MUL MULLION
NRC NOISE REDUCTION
COEFFICIENT
NOM NOMINAL
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NO NUMBER
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
OD OUTSIDE DIAMETER
OH OVERHEAD
PNT PAINT
PR PAIR
PNL PANEL
PTN PARTITION
PERF PERFORATE(D)
PERM PERIMETER
PLAS PLASTER
PLAM PLASTIC LAMINATE
PL PLATE
PLUMB PLUMBING
PLYWD PLYWOOD
PVC POLYVINYL CHLORIDE
FLR FLOOR
FD FLOOR DRAIN
FLUR FLUORESCENT
FT FOOT, FEET
FTG FOOTING
FND FOUNDATION
FRMG FRAMING
FURN FURNITURE
FURR FURRING
GAL GALLON
GALV GALVANIZED
GS GALVANIZED STEEL
G GAS
GA GAUGE
GEN GENERAL
GC GENERAL CONTRACTOR
GL GLASS
GWT GLAZED WALL TILE
GB GRAB BAR
GR GRADE
GFI GROUND FAULT CIRC.
INTERRUP.
GYP GYPSUM
HBD HARDBOARD
HDWR HARDWARE
HDWD HARDWOOD
HDR HEADER
HTR HEATER
HVAC HEATING, VENTILATING, AIR
CONDITIONING
HT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HW HOT WATER
HR HOUR
IN INCH
INCL INCLUDE
INFO INFORMATION
ID INSIDE DIAMETER
INST INSTALL(ATION)
INSUL INSULATE(ION)
INT INTERIOR
JAN JANITOR
JT JOINT
JST JOIST
JCT JUNCTION
JB JUNCTION BOX
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE
DP DAMPPROOFING
DEMO DEMOLISH, DEMOLITION
DMT DEMOUNTABLE
DEPT DEPARTMENT
DTL DETAIL
DIAG DIAGONAL
DIAM DIAMETER
DIM DIMENSION
DIV DIVISION
DR DOOR
DG DOOR GRILLE
DBL DOUBLE
DN DOWN
DT DRAIN TILE
DWR DRAWER
DWG DRAWING
DF DRINKING FOUNTAIN
DW DRYWALL
EA EACH
E EAST
EWC ELECTRIC WATER COOLER
ELEC ELECTRICAL
EPBD ELECTRICAL PANELBOARD
EL ELEVATION
ELEV ELEVATOR
EMER EMERGENCY
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
EXH EXHAUST
EF EXHAUST FAN
EXIST EXISTING
ETR EXISTING TO REMAIN
EXP EXPANSION
EJ EXPANSION JOINT
EXP C EXPOSED CONSTRUCTION
EXT EXTERIOR
FB FACE BRICK
FGL FIBERGLASS
FIN FINISH(ED)
FF FINISHED FLOOR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FHVC FIRE HOSE VALVE CABINET
FH FIRE HYDRANT
FR FIRE RATED
FRT FIRE RETARDANT TREATED
FVC FIRE VALVE CABINET
FIX FIXTURE
FLSHG FLASHING
ABV ABOVE
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
AWP ACOUSTICAL WALL PANEL
ADJ ADJUSTABLE
A/C AIR CONDITIONING
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AB ANCHOR BOLT
< ANGLE
APPR APPROXIMATE
ARCH ARCHITECT(URAL)
ASB ASBESTOS
@ AT
ATTEN ATTENUATION
AUTO AUTOMATIC
AVG AVERAGE
BSMT BASEMENT
BM BENCH MARK
BTWN BETWEEN
BLK BLOCK
BLKG BLOCKING
BD BOARD
BOT BOTTOM
BRK BRICK
BLDG BUILDING
BBD BULLETIN BOARD
CAB CABINET
C CARPET
CTL CARPET TILES
CI CAST IRON
CLG CEILING
CL CENTERLINE
CT CERAMIC TILE
CBD CHALKBOARD
CLR CLEAR
CCTV CLOSED CIRCUIT TELEVISION
CLOS CLOSET
CW COLD WATER
COL COLUMN
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCT(ION)
CONT CONTINUOUS
CONTR CONTRACT(OR)
CJ CONTROL JOINT
CG CORNER GUARD
CORR CORRIDOR
CNTR COUNTER
CFM CUBIC FEET PER MINUTE
ABBREVIATIONS DRAWING INDEX BUILDING CODE & FIRE ANALYSIS
COMMON SYMBOLS
KEY PLAN: SCALE (1/16" = 1'-0")
SHEET
NUMBER SHEET NAME
50% CD
SET
95% CD
SET
100% CD
SET
PERMIT &
PRICING
SPECIFICATIONS
SPEC SPECIFICATION BOOK X
ARCHITECTURAL
0 COVER X X X X
A000 DRAWING INDEX, COMMON SYMBOLS
AND KEYPLAN
X X X X
A001 CODE AND EGRESS X X X
A002 DOORS, WALLS, DETAILS, &
SCHEDULES
X X X X
A109 DEMOLITION PLAN X X X X
A110 DEMOLITION RCP PLAN X X X X
A209 CONSTRUCTION PLAN X X X X
A309 POWER & SIGNAL PLAN X X X X
A409 REFLECTED CEILING PLAN X X X X
A509 FINISH PLAN X X X X
A700 ELEVATIONS X X X X
A701 ELEVATIONS X X X
A800 DETAILS X X X
AG00 DC GREEN CODE X X X X
MECHANICAL
M001 MECHANICAL COVER SHEET X X X X
M109 MECHANICAL 9TH FLOOR
DEMOLITION PLAN
X X X X
M209 MECHANICAL 9TH FLOOR NEW WORK
PLAN
X X X X
M501 DETAIL SHEET X X X
M601 SCHEDULE SHEET X X X
PLUMBING
P001 PLUMBING COVER SHEET X X X X
P209 PLUMBING9TH FLOOR NEW WORK
PLAN
X X X X
P501 PLUMBING DETAIL & RISER SHEET X X X X
ELECTRICAL
E001 ELECTRICAL COVER SHEET X X X X
E109 ELECTRICAL 9TH FLOOR LIGHTING
PLAN
X X X X
E209 ELECTRICAL 9TH FLOOR POWER PLAN X X X X
E309 ELECTRICAL 9TH FLOOR HVAC
POWER PLAN
X X X X
E501 ELECTRICAL DETAIL SHEET X X X X
E601 ELECTRICAL RISER DIAGRAM &
SCHEDULE
X X X X
FIRE PROTECTION
F001 FIRE ALARM COVER SHEET X X X X
F109 FIRE ALARM 9TH FLOOR PLAN X X X X
FILE INFORMATION
SHEET NAME
MEP CONSULTANT:
ISSUES
SEAL / SIGNATURE
CLIENT
CONSULTANTS
© 2022 OTJ Architects, Inc.
Project No:
Drawn By:
Checked By:
DESCRIPTION
REVISION
NUMBER DATE
SCALE
Project Phase:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws an regulations of the
District of Columbia. I have pemvrsonally prepared, or directly supervised the development of, the architectural designs include in this application.
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
As indicated
BIM 360://Studio 2 - Test Fits - R20/S02_11728.00_550 12th St, SW_NIGC_ 9th Floor_R20.rvt
NATIONAL INDIAN GAMING COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
A000
DRAWING INDEX,
COMMON SYMBOLS
AND KEYPLAN
1110 NORTH GLEBE RD., Ste 300
GHT LIMITED CONSULTING
ENGINEERS
NIGC - 9TH FLOOR
11728.00
JM
MSC
ARLINGTON, VA 22201
P: 703.243.1200
50% DID REVIEW 1 7/27/23
100% DID REVIEW 2 8/22/23
50% CD SET 3 9/27/23
95% CD SET 4 10/26/23
100% CD SET 6 11/20/23
PERMIT & PRICING 7 01/04/24
#7
#6
#5
#1
#2
#3
#4
F.E.C.
F .E
.C
F.E.C.
F .E
.C
DN UP
DN UP
#7
#6
#5
#1
#2
#3
#4
09 FLOOR
OCCUPANCY LOAD CALCULATIONS:
Based Upon Table 1004.1.2 - 2015 IBC
Floor Area of Tenant Space: Square Footage
Total Floor Area: 09 FLOOR 39,357 GSF
Vertical Penetration: 09 FLOOR 1,179 USF
Mechanical/Electrical: 09 FLOOR 1,220 USF
Total Floor Usable Space: 09 FLOOR 36,958 USF
Total Usable Tenant Space: 09 FLOOR 15,072 USF
Occupant Load
USF / RATIO TOTAL OCCUPANCY
BUSINESS AREAS - GROSS: 13,449 100 135
ASSEMBLY AREAS (TABLE & CHAIRS) - NET: 1,213 15 81
ASSEMBLY AREAS (CHAIRS) - NET: - 7 0
STORAGE - GROSS: 410 300 2
EDUCATIONAL - CLASSROOM - NET: - 20 0
TOTAL TENANT OCCUPANCY 218
NIC/SHELL SPACE - GROSS: 21,886 100 219
TOTAL FLOOR OCCUPANCY = 437
09 FLOOR
EGRESS WIDTH PER OCCUPANT CALCULATIONS - FULL FLOOR
Based Upon Table 1005.3.1 & 1005.3.2 - 2015 IBC
STAIR DOOR WIDTH STAIR WIDTH
INCHES / RATIO INCHES / RATIO
EXIT #1 34 0.15 227 STAIR 1: 44 0.2 220
EXIT #2 34 0.15 227 STAIR 2: 44 0.2 220
EXIT #3 0 0.15 0 STAIR 3: 0 0.2 0
EXIT #4 0 0.15 0 STAIR 4: 0 0.2 0
TOTAL ALLOWED = 454 TOTAL ALLOWED = 440
THE LESSER NUMBER SHALL APPLY.
MINIMUM NUMBER OF PLUMBING FIXTURES - TABLE 2902.1
TYPE OF OCCUPANCY
OCCUPANT
LOAD
WATER CLOSETS *(URINAL SEE
SECTION 419.2) LAVATORIES
***DRINKING
FOUNTAINS
MALE FEMALE MALE FEMALE
BUSINESS 354 4.540 4.540 3.213 3.213 3.540
1 PER 25 FOR THE FIRST 50; 1 PER
50 THEREAFTER
1 PER 40FOR THE FIRST
80; 1 PER 80
THEREAFTER
1 PER 100
ASSEMBLY 81 0.324 0.623 0.203 0.203 0.1620
1 PER 125 1 PER 65 1 PER 200 1 PER 500
ASSEMBLY (A-4) 0 0.000 0.000 0.000 0.000 0.0000
1 PER 125 1 PER 65 1 PER 200 1 PER 500
STORAGE 2 0.010 0.010 0.010 0.010 0.002
1 PER 100 1 PER 100 1 PER 1000
EDUCATIONAL 0 0.000 0.000 0.000 0.000 0.000
1 PER 50 1 PER 50 1 PER 100
MERCANTILE 0 0.000 0.000 0.000 0.000 0.000
1 PER 500 1 PER 750 1 PER 1000
INSTITUTIONAL 0 0.000 0.000 0.000 0.000 0.000
1 PER 15 1 PER 15 1 PER 100
TOTAL REQUIRED 4.874 5.173 3.425 3.425 3.704
TOTAL PROVIDED 9 9 6 6 4***
*NOTE: MALE WC COUNT REDUCE/MODIFIED BY URINAL COUNT (REPLACING NO MORE THAN 1/2 OF REQUIRED
WC) PER 2015 IPC, SECTION 419.2
**FOR ADDITIONAL TOILET REQUIREMENTS , 2015 IPC 403.3.3 ALLOWS FOR PUBLIC TOILET FACILITIES TO BE LOCATED NOT MORE THAN ONE STORY ABOVE OR BELOW AND SHALL NOT EXCEED A DISTANCE OF 500 FEET.
***NOTE: DRINKING FOUNTAINS CALCULATION INCLUDE FILTRATION UNITS TO BE ADDED TO THE TENANT SPACE
PER 2015 IPC, SECTION 410.3.
****NOTE: 2015 IEBC SECTION 810 - OCCUPANT LOAD OF THE STORY HAS NOT INCREASED BY MORE THAN 20%, PLUMBING FIXTURE COUNT IS NOT REQUIRED TO INCREASE.
DTE-1
POD-1
DTE-3
DTE-2
POD-2
POD-3
DTE-4
POD-4
SE-1
FEC-1
FEC-2
FEC-3
FEC-4
TENANT ANALYSIS
ASSEMBLY 1
BUSINESS
MECH/ELEC
NIC
STORAGE
VERTICAL PENETRATION
784 USF
VP
13287 USF
BUSINESS
275 USF
CONF
113 USF
ASSEMBLY
115 USF
ASSEMBLY
589 USF
CONF
121 USF
ASSEMBLY
163 USF
STOR 201 USF
STOR
34 USF
STOR
157 USF
STOR
18 USF
STOR
395 USF
VP
562 USF
MECH/ELEC
91 USF
MECH/ELEC
98 USF
MECH/ELEC
21886 USF
NIC 469 USF
MECH/ELEC
MAXIMUM TRAVEL DISTANCE TO POINT OF DECISION (COMMON PATH OF EGRESS TRAVEL)(2015 IBC/2017 DCMR 12A 1006.2.1)
(SPRINKLER - MAXIMUM 100'-0")(NON-SPRINKLER - MAX 75'-0")
MAXIMUM TRAVEL DISTANCE TO FIRE STAIRWELL DOOR (2015 IBC/2017 DCMR 12A 1017.2)
(SPRINKLER - MAXIMUM 300'-0")(NON-SPRINKLER - MAX. 200'-0")
REMOTENESS OF EGRESS DOORS (2015 IBC/2017 12 DCMR A 1007.1.1 EXEMPTION #2)
(SPRINKLER - 1/4 OF LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED) (NON-SPRINKLER -
1/2 OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED)
DEAD ENDS
(2015 IBC 1020.4, EXCEPTION #2) (SPRINKLER - SHALL NOT EXCEED 50'-0") (NON-SPRINKLER - SHALL NOT EXCEED 20'-0")
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED PER (2015 IBC/SECTION 906 AND 2010 NFPA 10) (75'-0" RADIUS) PORTABLE FIRE EXTINGUISHERS - GROUP B & A3 - LIGHT (LOW) HAZARD, CLASS A HAZARDS (NFPA 10, 1.4.1) EXTINGUISHER - 2A MINIMUM RATED EXTINGUISHER, 1/3,000 SF MAXIMUM FLOOR AREA PER A UNIT, 11,250 SF MAXIMUM FLOOR AREA PER SINGLE UNIT, 75' MAX TRAVEL DISTANCE IBC 906.2 (1). PROVIDED EXTINGUISHER TYPE 4A: 10BC MULTIPURPOSE DRY-
CHEMICAL.
1.
2.
3.
4.
5.
PRIOR TO THE INSTALLATION OR RENOVATION OF THE PROJECT'S AUTOMATIC SPRINKLERS SYSTEM, THE GENERAL CONTRACTOR SHALL CONFIRM IF SPRINKLER SYSTEM HEADS ARE "QUICK RESPONSE". IF NOT, GENERAL CONTRACTOR SHALL INSTALL ARCHITECT APPROVED PORTABLE FIRE EXTINGUISHERS (OVAL BRAND) WHICH COMPLIES WITH THE 2017 DC
BUILDING CODE SECTION 906.
6.
GENERAL CONTRACTOR SHALL VERIFY THAT THE EXIT SIGNAGE LOCATED AT THE EXIT STAIRWAY, EXIT PASSAGE WAY & EXIT
DISCHARGE SHALL COMPLY WITH SECTION 1013.4 OF THE 2017 DC BUILDING CODE.
7.
GENERAL CONTRACTOR SHALL PROVIDE & INSTALL PORTABLE FIRE EXTINGUISHERS PER (2015 IBC/2017 DCMR SECTION
3309.1 AND SECTION 906) WHERE REQUIRED. STRUCTURES UNDER CONSTRUCTION, ALTERNATION OR DEMOLITION SHALL BE PROVIDED WITH NO FEWER THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH SECTION 906
AND SIZED FOR NOT LESS THAN ORDINARY HAZARD AS FOLLOWS:
A. AT EACH STAIRWAY ON ALL FLOORS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED;
B. IN EVERY STORAGE AND CONSTRUCTION SHED;
C. ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE SPECIAL HAZARDS EXIST, SUCH AS THE
STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS.
8.
GENERAL CONTRACTOR SHALL PROVIDE & INSTALL RAISED CHARACTER AND BRAILLE EXIT SIGNS PER (2015 IBC/2017 DCMR 1013.4). A SIGN STATING EXIT IN VISUAL CHARACTERS, RAISED CHARACTERS, AND BRAILLE AND COMPLYING WITH ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN
EXIT STAIRWAY OR RAMP, AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE.
10.
PROVIDE & INSTALL OCCUPANT LOAD SIGNS POSTED IN ACCORDANCE WITH SECTION (ICC A117.1 AND IBC/DCMR SECTION 1004.3). ROOMS OR SPACES WHICH HAVE MULTIPLE USE CAPABILITY SHALL BE POSTED FOR THE OCCUPANT LOADS OF ALL SUCH USED. PER (2015 IBC/2017 DCMR 1004.3) POSTING OF OCCUPANT LOAD. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR OWNER'S AUTHORIZED AGENT.
9.
TENANT AREA ANALYSIS (SCALE: 1/16"=1'-0")
BUILDING CODE ANALYSIS / FIRE & LIFE SAFETY PLAN (SCALE: 1/16"=1'-0")
BUILDING CODE ANALYSIS
SCHEDULE - TRAVEL DISTANCE
Mark Path ID Travel Distance Type Comments Level
DISTANCE TO EXIT LINE
DTE-1 DISTANCE TO EXIT LINE 160' - 4" NOTE #2 11
DTE-2 DISTANCE TO EXIT LINE 232' - 4" NOTE #2 11
DTE-3 DISTANCE TO EXIT LINE 261' - 5 1/2" NOTE #2 11
DTE-4 DISTANCE TO EXIT LINE 211' - 6" NOTE #2 11
FIRE EXTINGUISHER CAB
FEC-1 FIRE EXTINGUISHER CAB 75' - 0" NOTE #5 11
FEC-2 FIRE EXTINGUISHER CAB 75' - 0" NOTE #5 11
FEC-3 FIRE EXTINGUISHER CAB 75' - 0" NOTE #5 11
FEC-4 FIRE EXTINGUISHER CAB 75' - 0" NOTE #5 11
POINT OF DECISION LINE
POD-1 POINT OF DECISION LINE 25' - 11" NOTE #1 11
POD-2 POINT OF DECISION LINE 51' - 10 1/2" NOTE #1 11
POD-3 POINT OF DECISION LINE 62' - 9" NOTE #1 11
POD-4 POINT OF DECISION LINE 24' - 3 1/2" NOTE #1 11
SEPARATION OF EXIT
SE-1 SEPARATION OF EXIT 16' - 7" NOTE #3 11
FILE INFORMATION
SHEET NAME
MEP CONSULTANT:
ISSUES
SEAL / SIGNATURE
CLIENT
CONSULTANTS
© 2022 OTJ Architects, Inc.
Project No:
Drawn By:
Checked By:
DESCRIPTION
REVISION
NUMBER DATE
SCALE
Project Phase:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws an regulations of the
District of Columbia. I have pemvrsonally prepared, or directly supervised the development of, the architectural designs include in this application.
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
As indicated
BIM 360://Studio 2 - Test Fits - R20/S02_11728.00_550 12th St, SW_NIGC_ 9th Floor_R20.rvt
NATIONAL INDIAN GAMING COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
A001
CODE AND EGRESS
1110 NORTH GLEBE RD., Ste 300
GHT LIMITED CONSULTING
ENGINEERS
NIGC - 9TH FLOOR
11728.00
JM
MSC
ARLINGTON, VA 22201
P: 703.243.1200
95% CD SET 4 10/26/23
THERMOSTAT
LIGHT SWITCH & PUSH BUTTON
STROBE & SECURITY OUTLET BOXES
(MEASURE TO BOTTOM OF FIXTURE)
ALIGN
ELECTRICAL OUTLET
TELEPHONE / DATA OUTLETNOTES:
• STROBES, LIGHT SWITCHES, AND ETC. DEVICES TO ALIGN AS SHOWN.
• ALL ADJACENT DEVICES TO BE GANGED UNDER THE SAME COVER PLATE WHENEVER FEASIBLE.
• GENERAL CONTRACTOR SHALL BE REQUIRED TO RELOCATE ITEMS AT NO ADDITIONAL COST TO TENANT, ARCHITECT OR BUILDING OWNER
• ALL DEVICES AND COVER PLATES TO BE WHITE UNLESS NOTED OTHERWISE. COVER PLATES
FOR ALL DEVICES MOUNTED IN MILLWORK, TILE, OR OTHER SPECIALTY FINISHES TO BE
STAINLESS OR ALUMINUM. SEE ARCHITECTURAL AND MEP PLANS FOR FURTHER INFORMATION.
• MOUNT COAT HOOK ON WALL WHERE GLASS LITES IN DOORS PROHIBIT INSTALLATION OF COAT HOOKS
ON DOOR. LOCATE COAT HOOK IN FIELD WITH ARCHITECT.
CO2 SENSORS
CARD READER
O R
B
U
IL
D
IN
G S
T A
N D
A R
D
COAT HOOK
6"
'-6
'-0
A F
F A
T N
O O
R F
U L
L
B A
C K
S P
L A
S H
U
N O
'-2
T Y
P
'-6
A
F F
T Y
P
(F O
R A
C C
/A N
S I
A F
F
EQ EQ
'-8
A F
F A
T
B
A C
K S
P L A
S H
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.
(25GA)
(20GA)
11'-8"
12'-6"
13'-4"
14'-4"
1A
1B
1C
1D
1E
STUD SIZE
1-5/8"
2-1/2"
3-5/8"
4"
6"
SLAB TO SLAB PARTITION
13'-7"
14'-8"
15'-6"
16'-9"
14'-4"
16'-0"
16'-4"
18'-4"
19'-2"
21'-0"
21'-11"
24'-0"
FIRE RATING
ACOUSTIC
PROPERTIES
STC INSUL THK
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
CUT STUDS 1/2" SHORT OF TOP
RUNNER TO ALLOW FOR DEFLECTION,
DO NOT FASTEN GYP. BD. TO RUNNER
CONT ACOUSTICAL
SEALANT
1-1/2"
1-1/2"
3"
3"
3"
3"
3"
3"
- (25GA)
(20GA)
11'-8"
12'-6"
13'-4"
14'-4"
2A
2B
2C
2D
2E
1-5/8"
2-1/2"
3-5/8"
4"
6"
GRID BREAK
13'-7"
14'-8"
15'-6"
16'-9"
14'-4"
16'-0"
16'-4"
18'-4"
19'-2"
21'-0"
21'-11"
24'-0"
STC INSUL THK
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
1-1/2"
1-1/2"
3"
3"
3"
3"
3"
3"
(25GA)
(20GA)
3A
3B
3C
3D
3E
1-5/8"
2-1/2"
3-5/8"
4"
FURRED OUT PARTITION
STC INSUL THK
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
-7/8" HAT
CHANNEL
(25GA)
(20GA)
11'-8"
12'-6"
13'-4"
14'-4"
4A
4B
4C
4D
4E
1-5/8"
2-1/2"
3-5/8"
4"
6"
SLAB TO SLAB PARTITION
13'-7"
14'-8"
15'-6"
16'-9"
14'-4"
16'-0"
16'-4"
18'-4"
19'-2"
21'-0"
21'-11"
24'-0"
STC INSUL THK
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
1-1/2"
1-1/2"
3"
3"
3"
3"
3"
3"
-(25GA)
(20GA)
11'-8"
12'-6"
13'-4"
14'-4"
5A
5B
5C
5D
5E
1-5/8"
2-1/2"
3-5/8"
4"
6"
SLAB TO CEILING
13'-7"
14'-8"
15'-6"
16'-9"
14'-4"
16'-0"
16'-4"
18'-4"
19'-2"
21'-0"
21'-11"
24'-0"
STC INSUL THK
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
(25GA)
(20GA)
1-1/2"
1-1/2"
3"
3"
3"
3"
3"
3"
ACOUSTIC
PROPERTIES
ACOUSTIC
PROPERTIES
ACOUSTIC
PROPERTIES
ACOUSTIC
PROPERTIES
SLAB TO SLAB PARTITION ACOUSTIC
PROPERTIES
STC INSUL THK
6B 14'-4"
16'-0"
16'-4"
18'-4"
(25GA)
(20GA)
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF FLOOR
SLAB.
SCHEDULED CEILING
SEE RCP.
LINE OF STRUCTURE
ABOVE, CONCRETE SLAB
OR STEEL DECK.
ACOUSTICAL CAULK AT
SLAB/WALL JOINT, BOTH SIDES.
TOP TRACK.
GYPSUM WALL BOARD.
METAL STUD.
MINERAL WOOL BATT
INSULATION
SEE
SCHEDULE
CONT ACOUSTICAL
SEALANT
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF FLOOR
SLAB.
SCHEDULED CEILING
SEE RCP.
LINE OF STRUCTURE
ABOVE, CONCRETE SLAB
OR STEEL DECK.
ACOUSTICAL CAULK AT
SLAB/WALL JOINT, BOTH SIDES.
TOP TRACK.
GYPSUM WALL BOARD.
METAL STUD.
MINERAL WOOL BATT
INSULATION
SEE
SCHEDULE
CUT STUDS 1/2" SHORT OF TOP
RUNNER TO ALLOW FOR DEFLECTION.
CONT ACOUSTICAL
SEALANT
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF FLOOR
SLAB.
SCHEDULED CEILING
SEE RCP.
LINE OF STRUCTURE
ABOVE, CONCRETE SLAB
OR STEEL DECK.
ACOUSTICAL CAULK AT
SLAB/WALL JOINT, BOTH
SIDES.
TOP TRACK.
GYPSUM WALL BOARD.
METAL STUD.
MINERAL WOOL BATT
INSULATION
SEE
SCHEDULE
LINE OF STRUCTURE
ABOVE, CONCRETE SLAB.
GYPSUM WALL BOARD,
QUANTITY OF LAYERS AS
SCHEDULED
METAL STUD.
FLOOR TRACK.
LINE OF STRUCTURE
COLUMN OR WALL.
TOP TRACK.
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF FLOOR
SLAB.
SEE
SCHEDULE
SCHEDULED CEILING SEE RCP.
CLEAR SILICONE
JOINT
WD. BLOCKING TYP.
1/2" TEMPERED GLAZING
SATIN METAL FINISH
ALUMINUM GLAZING RAIL
RECESSED IN DRYWALL TYP.
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF STRUCTURE ABOVE,
CONCRETE SLAB OR STEEL
DECK.ACOUSTICAL CAULK AT
SLAB/WALL JOINT, BOTHSIDES.
TOP TRACK.
SEE
SCHEDULE
CONT ACOUSTICAL
SEALANT
6C 14'-4"
16'-0"
16'-4"
18'-4"
(25GA)
(20GA)
6D 4" 14'-4"
16'-0"
16'-4"
18'-4"
(25GA)
(20GA)
3-5/8"
2-1/2"
CUT STUDS 1/2" SHORT OF
TOP RUNNER TO ALLOW
FOR DEFLECTION.
SCHEDULED CEILING SEE RCP.
CUT STUDS 1/2" SHORT OF TOP
RUNNER TO ALLOW FOR DEFLECTION,
DO NOT FASTEN GYP. BD. TO RUNNER
CONT ACOUSTICAL
SEALANT
F L
O O
R P
L A
N C
E
IL
IN
G
P L
E N
U M
LINE OF FLOOR
SLAB.
SCHEDULED CEILING
SEE RCP.
LINE OF STRUCTURE
ABOVE, CONCRETE SLAB
OR STEEL DECK.
ACOUSTICAL CAULK AT
SLAB/WALL JOINT, BOTH
SIDES.
TOP TRACK.
(2) GYPSUM WALL
BOARD.
METAL STUD.
MINERAL WOOL BATT
INSULATION
SEE
SCHEDULE
GWB
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
NOTE: SHADED WALL TYPES NOT USED IN PROJECT
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.STUD SIZE GWB
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.STUD SIZE GWB
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.STUD SIZE GWB
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.STUD SIZE GWB
LIMITING HEIGHT:
5 PSF LATERAL LOAD
L/240 MAX DEFLECTION
STUD GAUGE 24" O.C. 16" O.C.STUD SIZE GWBFIRE RATING FIRE RATING FIRE RATING FIRE RATING FIRE RATING
RESILIENT, SDT OR
VINYL FLOORING
CARPET
DOOR FRAMETRANSITION PROFILE: SCHLUTER
SCHIENE SERIES W/ SATIN
ANODIZED ALUMINUM FINISH.
PROVIDE PROFILE/SIZE
APPROPRIATE TO
MATERIALS INSTALLED.
/2
T
Y P
DOOR AS
SPECIFIED, WHERE
OCCURS
DOOR FRAME
DOOR AS SPECIFIED,
WHERE OCCURS
CARPET
/2
T
Y P
PAINTED
HOLLOW METAL
FRAME
SOLID CORE
WOOD DOOR
SOLID CORE
WOOD DOOR
JAMB ANCHOR
PAINTED
HOLLOW METAL
FRAME
MTL STUD FRAMING
WD BLOCKING
CONCEALED CLOSER
CEILING FLUSH HEAD
TRIM
HARDWARE RAIL BEYOND
METAL HEADER STOP
WITH DOOR SILENCER
1/2" THICK TEMPERED
GLASS DOOR
EDGE OF CASED
OPENING
PATCH HARDWARE
BEYOND
1/2" THICK TEMPERED
GLASS DOOR
EDGE OF CASED
OPENING
SCHEDULED DOOR PULLS
1/2" THICK TEMPERED
GLASS DOOR
1/8" CLEAR
SCHEDULED
PARTITION
A S
S C
H E
D
EQ. EQ.
DOOR TYPE D4
AS SCHED.
DOOR TYPE D1
AS SCHED.
A S
S C
H E
D
EQ. EQ.
DOOR TYPE D6
ARCHIVE
TEMPERED GLAZING (TYPICAL)
FULL TOP/BOTTOM RAIL PATCH PLATES
DOOR TYPE D5
AS SCHED.
DOOR TYPE D7
ARCHIVE
M
IN
M
IN
A S
S C
H E
D
DOOR TYPE D2
AS SCHED.
SL
3' - 0"
A S
S C
H E
D
DOOR TYPE D3
AS SCHED.
CASED
OPENING
FRAME AS SCHEDULED
THESE RELOCATED TEMPERED
GLASS DOORS ARE USED TO
PROTECT TENANT'S ARTIFACT
DISPLAYS AND ARE NOT FOR
DAILY USAGE.
SCHEDULE - DOORS
DOOR FRAME
HARDWARE
SET COMMENTS
DOOR
NUMBER ROOM NAME
SIZE
MATERIAL TYPE THRESHOLD FINISH MATERIAL FINISH
DETAIL
W H T HEAD JAMB
900 RECEPTION 6' - 0" 7' - 5" 1/2" GLASS D4 T2 CLEAR - - ETR ETR HW - 6 EXISTING TO REMAIN DOOR, NEW HARDWARE
901 EXECUTIVE CONF. ROOM 3' - 0" 7' - 5" 1/2" GLASS D5 T1 CLEAR - - H2 J3 HW - 7
902 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 2
903 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
904 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
905 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
906 OFFICE (CHIEF OFFICER) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
907 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
908 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
909 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
910 OFFICE (CHIEF OFFICER) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
911 OFFICE (CHIEF OF STAFF) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
912 OFFICE (CHIEF OF STAFF) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
913 OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
914 GC OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
915 OGC EXEC. ADMIN 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
916 ASST. GC OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
917 ASST. GC OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
918 EXEC. ADMIN. OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
919 CHAIR OFFICE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
920 VICE CHAIR (COMMISSION) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 2
921 COMMISSIONER (COMMISSION) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 2
923 SMALL CONF ROOM 3' - 0" 7' - 5" 1/2" GLASS D5 T2 CLEAR - - H2 J3 HW - 7
924 COMM. COPY / STORAGE ROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 8
925 WELLNESS ROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 4
926 PHONE ROOM 3' - 0" 7' - 5" 1/2" GLASS D5 T1 CLEAR - - H2 J3 HW - 7
927A PA STORAGE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 8
928A MEDIA WORKROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 1
928B MEDIA WORKROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 STAIN HM PAINT H1 J1 HW - 1
930A STORAGE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 8
930B STORAGE 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 8
931A IT WORK ROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 3
931B IT WORK ROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 STAIN HM PAINT H1 J1 HW - 3
932A CASED OPENING 3' - 6" 1 3/4" - D3 T1 PAINT HM PAINT - - -
932B CASED OPENING 3' - 6" 1 3/4" - D3 T1 PAINT HM PAINT - - -
933 CASED OPENING 3' - 6" 1 3/4" - D3 T1 PAINT HM PAINT - - -
935 LAN ROOM 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 ETR ETR PAINT ETR ETR HW - 3 EXISTING TO REMAIN DOOR, NEW HARDWARE
936 FINGERPRINTING 3' - 0" 7' - 5" 1 3/4" SCWD D1 T2 ETR ETR PAINT ETR ETR HW - 1 EXISTING TO REMAIN DOOR, NEW HARDWARE
937 HOTELING (OGC) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 ETR ETR PAINT ETR ETR HW - 3 EXISTING TO REMAIN DOOR, NEW HARDWARE
938 HOTELING (OGC) 3' - 0" 7' - 5" 1 3/4" SCWD D1 T1 ETR ETR PAINT ETR ETR HW - 3 EXISTING TO REMAIN DOOR, NEW HARDWARE
940A ARCHIVE 1 2' - 8 1/2" 7' - 6" 1/2" GLASS D6 - CLEAR - - ETR ETR ETR RELOCATED DOOR FROM TENANT SUITE, VENDOR TO INSTALL
940B ARCHIVE 1 2' - 8 1/2" 7' - 6" 1/2" GLASS D6 - CLEAR - - ETR ETR ETR RELOCATED DOOR FROM TENANT SUITE, VENDOR TO INSTALL
941A ARCHIVE 2 2' - 11 1/2" 7' - 7" 1/2" GLASS D7 - CLEAR - - ETR ETR ETR RELOCATED DOOR FROM TENANT SUITE, VENDOR TO INSTALL
941B ARCHIVE 2 2' - 11 1/2" 7' - 7" 1/2" GLASS D7 - CLEAR - - ETR ETR ETR RELOCATED DOOR FROM TENANT SUITE, VENDOR TO INSTALL
941C ARCHIVE 2 2' - 11 1/2" 7' - 7" 1/2" GLASS D7 - CLEAR - - ETR ETR ETR RELOCATED DOOR FROM TENANT SUITE, VENDOR TO INSTALL
942 CORRIDOR 3' - 0" 7' - 5" 1/2" GLASS D5 - CLEAR - - H2 J2 HW - 5
943 GIVE BACK AREA 3' - 0" 7' - 5" 1 3/4" SCWD D1 ETR ETR ETR ETR ETR ETR ETR EXISTING TO REMAIN DOOR
944 GIVE BACK AREA 3' - 0" 7' - 5" 1 3/4" SCWD D1 ETR ETR ETR ETR ETR ETR ETR EXISTING TO REMAIN DOOR
PARTITION TYPES
DOOR HARDWARE SETS
GENERAL NOTES - DOOR HARDWARE
1 ALL EGRESS DOORS WITH LOCKSETS SHALL COMPLY WITH ANSI 117.1 - 2009 SECT. 404, INCLUDING 404.2.6 AND 2017 DC CONSTRUCTION CODE 1010.1.9 AND SHALL BE MADE WITHOUT THE USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT IN
THE DIRECTION OF EGRESS.
2 ALL DOOR HARDWARE, CLOSERS, ETC., MUST MEET THE REQUIREMENTS OF 2017 DC CONSTRUCTION CODE SECTION
1010.1.9.4 MEANS OF EGRESS LOCKS AND LATCHES, SECTION 1010.1.2 AND 1010.1.3 REGARDING DOOR SWING AND
OPENING FORCE.
3 ALL DOOR HARDWARE FOR SENSOR RELEASE OF ELECTRICALLY LOCKED EGRESS DOORS SHALL COMPLY WITH THE
REQUIREMENTS OF 2017 DC CONSTRUCTION CODE SECTION 1010.1.9.8.
4 ALL ELECTROMAGNETICALLY LOCKED EGRESS DOORS SHALL COMPLY WITH THE REQUIREMENTS OF 2017 DC
CONSTRUCTION CODE SECTION 1010.1.9
5 ALL DOOR OPERATIONS FOR UNLATCHING SHALL COMPLY WITH 2017 DC CONSTRUCTION CODE 1010.1.9.5.
6 ALL DELAYED EGRESS DOOR HARDWARE SHALL COMPLY WITH THE REQUIREMENTS OF 2017 DC CONSTRUCTION CODE SECTION 1010.1.9.7. ELECTROMAGNETICALLY LOCKED EGRESS DOORS AND THE 2015 NFPA 101 SECTION SHOULD BE
7.2.1.5.6 ELECTRICALLY CONTROLLED EGRESS DOOR ASSEMBLIES
7 THE BUILDING KEYWAY IS TO BE VERIFIED WITH THE CHIEF BUILDING ENGINEER. ALL NEW AND EXISTING LOCKS ARE TO BE KEYED TO THE BUILDING MASTER. PROVIDE OTHER MASTER KEY SYSTEMS IN A QUANTITY TO BE DETERMINED WITH TENANT, BUILDING MANAGEMENT AND ARCHITECT. QUANTITIES OF EACH KEY TYPE TO BE DETERMINED WITH TENANT, BUILDING MANAGEMENT, AND ARCHITECT. COORDINATE ALL BITING AND PINNING WITH THE BUILDING MANAGEMENT.
8 ANY EXISTING RE-USED HARDWARE SHALL BE RE-KEYED TO MATCH THE REQUIREMENTS STATED BY THE BUILDING
MANAGEMENT, TENANT AND ARCHITECT.
9 ALL DOORS OPENING INTO COMMON, UNSECURED AREAS, AND ALL DOORS INSTALLED IN SECURE PARTITIONS, SHALL
HAVE NON-REMOVABLE PINS.
10 ALL DOORS OPENING INTO LAN, HVAC, OR OTHER ROOMS WITH NOISE-PRODUCING MECHANICAL OR ELECTRICAL EQUIPMENT TO HAVE CONTINUOUS RUBBER GASKET SEALS AROUND FULL EXTENT OF DOOR FRAME AND HEAD, AND A DROP-DOWN SOUND SEAL AND ASSOCIATED THRESHOLD, TO PREVENT NOISE TRANSMISSION INTO SURROUNDING AREAS.
11 DO NOT THRU BOLT SURFACE MOUNTED CLOSERS
12 ALL GLASS DOORS, GLASS SIDELITES, AND GLASS DOOR LITES TO USE TEMPERED SAFETY GLASS AS REQUIRED BY 2017 DC CONSTRUCTION CODE, CHAPTER 24, SECTIONS AND SUBSECTIONS OF 2406. ALL SAFETY GLAZING TO BE PERMANENTLY MARKED WITH THE MANUFACTURER'S DESIGNATION, THE MANUFACTURER OR INSTALLER, GLASS TYPE AND THICKNESS, AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES.
13 ALL WOOD BLOCKING SHALL BE FIRE-RETARDANT TREATED WOOD, U.N.O.
FILE INFORMATION
SHEET NAME
MEP CONSULTANT:
ISSUES
SEAL / SIGNATURE
CLIENT
CONSULTANTS
© 2022 OTJ Architects, Inc.
Project No:
Drawn By:
Checked By:
DESCRIPTION
REVISION
NUMBER DATE
SCALE
Project Phase:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws an regulations of the
District of Columbia. I have pemvrsonally prepared, or directly supervised the development of, the architectural designs include in this application.
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
As indicated
BIM 360://Studio 2 - Test Fits - R20/S02_11728.00_550 12th St, SW_NIGC_ 9th Floor_R20.rvt
NATIONAL INDIAN GAMING COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
A002
DOORS, WALLS,
DETAILS, & SCHEDULES
1110 NORTH GLEBE RD., Ste 300
GHT LIMITED CONSULTING
ENGINEERS
NIGC - 9TH FLOOR
11728.00
JM
MSC
ARLINGTON, VA 22201
P: 703.243.1200
DOOR/FRAME TYPES
TRANSITION TYPES
100% DID REVIEW 2 8/22/23
50% CD SET 3 9/27/23
95% CD SET 4 10/26/23
100% CD SET 6 11/20/23
PERMIT & PRICING 7 01/04/24
3" = 1'-0"
T1 CARPET TO RESILIENT FLOOR TRANSITION
3" = 1'-0"
T2 CARPET TO CARPET FLOOR TRANSITION
3" = 1'-0"
H1 HOLLOW METAL FRAME AT HEAD
3" = 1'-0"
J1 HOLLOW METAL FRAME AT JAMB
DOOR FRAME DETAILS
3" = 1'-0"
H2 GLASS DOOR AT HEAD - SWINGING
3" = 1'-0"
J2 GLASS DOOR AT JAMB IN GYP WALL
3" = 1'-0"
J3 GLASS DOOR AT JAMB IN GLASS WALL
# DESCRIPTION CAT # FINISH MANUF
HW-5 - SINGLE GLASS DOOR WITH CARD READER
1 PAIR OF DOOR PULLS BACK TO BACK (SPEC)
1 CONCEALED CLOSER WITH NO HOLD OPEN
1 CARD READER (ROOM EXTERIOR)
1 EASI-RELEASE ELECTRONIC EGRESS MOTION
DETECTOR SWITCH @ CEILING
1 EMERGENCY ACTIVATOR RELEASE BUTTON
1 ELECTROMAGNETIC LOCK (ELECTRICALLY
UNLOCKED)(FAIL SECURE) FULL TOP & BOTTOM RAILS
1 PIVOT HINGE (TOP & BOTTOM)
1 HEADER STOP WITH SILENCERS
1 FLOOR MOUNTED DOOR STOP
HW-6 - DOUBLE GLASS DOOR WITH CARD READER
2 PAIR OF DOOR PULLS BACK TO BACK (SPEC)
2 CONCEALED CLOSER WITH NO HOLD OPEN
1 CARD READER (ROOM EXTERIOR)
1 EASI-RELEASE ELECTRONIC EGRESS MOTION
DETECTOR SWITCH @ CEILING
1 EMERGENCY ACTIVATOR RELEASE BUTTON
1 ELECTROMAGNETIC LOCK (ELECTRICALLY
UNLOCKED)(FAIL SECURE) FULL TOP & BOTTOM RAILS
2 PIVOT HINGE (TOP & BOTTOM)
1 HEADER STOP WITH SILENCERS
2 FLOOR MOUNTED DOOR STOP
HW-7 - SINGLE GLASS DOOR - NON LOCKING
1 PAIR OF DOOR PULLS BACK TO BACK (SPEC)
1 CONCEALED CLOSER WITH NO HOLD OPEN
1 PIVOT HINGE (TOP & BOTTOM)
1 HEADER STOP WITH SILENCERS
1 FLOOR MOUNTED DOOR STOP
HW-8 - SINGLE WOOD DOOR - LOCKING W/CLOSER
1 MORTISED LEVER LOCKSET - STOREROOM FUNCTION
1 SURFACE MOUNTED PARALLEL ARM CLOSER ON
INTERIOR WITH 90 DEGREE - HOLD OPEN
2 PAIR BUTT HINGES
1 FLOOR MOUNTED DOOR STOP
# DESCRIPTION CAT # FINISH MANUF
HW-1 - SINGLE WOOD DOOR LOCKING
1 CYLINDRICAL LEVER LOCKSET - OFFICE FUNCTION
2 PAIR BUTT HINGES
1 FLOOR MOUNTED DOOR STOP
1 COAT HOOK
HW-2 - SINGLE WOOD DOOR - LOCKING W/CARD READER
1 MORTISED LEVER LOCKSET - CLASSROOM FUNCTION
1 ELECTRIC STRIKE
1 CARD READER (ROOM EXTERIOR)
1 EASI-RELEASE ELECTRONIC EGRESS MOTION
DETECTOR SWITCH @ CEILING
2 PAIR BUTT HINGES
1 FLOOR MOUNTED DOOR STOP
1 COAT HOOK
HW-3 - SINGLE WOOD DOOR - CARD READER W/CLOSER
1 MORTISED LEVER LOCKSET - STOREROOM FUNCTION
1 ELECTRIC STRIKE
1 CARD READER (ROOM EXTERIOR)
1 SURFACE MOUNTED PARALLEL ARM CLOSER ON
INTERIOR WITH 90 DEGREE - NO HOLD OPEN
2 PAIR BUTT HINGES
1 FLOOR MOUNTED DOOR STOP
HW-4 - SINGLE WOOD DOOR - LOCKING W/CLOSER (LACTATION/ADA RESTROOM)
1 MORTISED LEVER LOCKSET - PRIVACY FUNCTION
1 THUMBTURN INDICATOR (SPEC)
1 SURFACE MOUNTED PARALLEL ARM CLOSER ON
INTERIOR WITH 90 DEGREE - NO HOLD OPEN
2 PAIR BUTT HINGES
1 FLOOR MOUNTED DOOR STOP
1 COAT HOOK
7'- 5"
7'- 5"
7'- 5"
TV
TV
TVTV
TV
TV
E
E E
E T V
E
E
E E
E
E
E
TV
E
E E
E
EE
E
TVTV
ETV
E TV
E E
E
E
E
E
E
E
E
E
E
E E
E
E E
E
E
E
ETV
E
ETV
E
TV E
TVTV
TV TV
TV TV
TV
TV
TV
TV
TV
TV
E
E E
E
E
E
E
E
TV
E
E E
E
TV
E
D
TV
TV
E
E
E
E E
E
E E E
E
GFI
R
DN UP
DN UP
#7
#6
#5
#1
#2
#3
#4
EXISTING DOOR AND FRAME TO
REMAIN
DEMOLISHED/RELOCATED DOOR
AND FRAME
EXISTING PARTITION TO REMAIN
DEMOLISHED PARTITION
DEMOLISHED MILLWORK
D3
D1
D1
D2
D2
KEY NOTES - DEMOLITION
D1 GC TO DEMO WALL TO THE EXTENT NECESSARY TO CREATE A 3'-0 X 7'-0" FRAMED OPENING.
D2 GC TO DEMOLISH EXISTING DOOR AT THIS LOCATION. SALVAGE DOOR FOR OWNER RE-USE.
D3 GC TO DEMOLISH EXISTING DEMOUNTABLE PARTITION AND ITS RELATED PARTS IN THIS ROOM.
DEMOLITION LEGENDGENERAL NOTES - DEMOLITION
13 CONTRACTOR SHALL REMOVE ALL MATERIALS ABOVE CEILING NOT SPECIFICALLY INDICATED TO REMAIN. ALL UNUSED WIRING, CABLES, CONDUIT, ETC. SHALL BE REMOVED AND STRIPPED BACK TO ORIGINAL SOURCE. THIS INCLUDES DATA CABLING THAT WILL
NOT BE REUSED.
14 ALL ABANDONED TELE/DATA RUNS AND TERMINATIONS SHALL BE REMOVED (REMOVE BOX AND COVER PLATE, PATCH WALL TO
LIKE-NEW CONDITION).
15 ALL ABANDONED ELECTRICAL OUTLETS SHALL HAVE THE BOX REMOVED TO THE PANEL. REMOVE BOX AND COVER PLATE, PATCH
WALL TO LIKE-NEW CONDITION.
16 REMOVE ALL FLOOR FINISHES, WALL COVERINGS AND SPECIALTY FINISHES, AND WALL BASE UNLESS OTHERWISE NOTED IN AREAS OF NEW CONSTRUCTION. PREPARE WALL, FLOOR, AND CEILING SURFACES FOR NEW FINISH AS SPECIFIED. BASE BID SHALL
INCLUDE ALL NECESSARY FLOOR PREP WORK TO ACCEPT NEW SPECIFIED FLOOR FINISHES.
17 PREPARE WALL, FLOOR, AND CEILING SURFACES FOR NEW FINISH AS SPECIFIED.
18 SALVAGE ALL DOORS, FRAMES, AND HARDWARE FOR REUSE UNLESS NOTED OTHERWISE.
19 ALL CEILINGS ARE TO REMAIN UNLESS NOTED OTHERWISE ON THE DEMOLITION OR REFLECTED CEILING PLANS.
20 ANY EXISTING BLINDS SHALL BE BOUND AND WRAPPED DURING DEMOLITION AND CONSTRUCTION, UNLESS SPECIFICALLY NOTED
TO BE REMOVED.
21 GENERAL CONTRACTOR SHALL RETAIN ALL WASTE HAULING TICKETS AND RETAIN NO LESS THAN 50% OF NONHAZARDOUS CONSTRUCTION WASTE WHICH SHALL BE DIVERTED FROM DISPOSAL BY RECYCLING OR SALVAGE OF CONSTRUCTION MATERIALS
AND WASTE IBC SECTION 503
22 GENERAL CONTRACTOR SHALL RETAIN ALL WASTE HAULING TICKETS AND RETAIN NO LESS THAN 50% OF NONHAZARDOUS CONSTRUCTION WASTE WHICH SHALL BE DIVERTED FROM DISPOSAL BY RECYCLING OR SALVAGE OF CONSTRUCTION MATERIALS
AND WASTE AS STATED IN THE 2013 DC GREEN CONSTRUCTION SECTION 503
23 STRUCTURES UNDER CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL BE PROVIDED WITH NO FEWER THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH SECTION 906 AND SIZED FOR NOT LESS THAN ORDINARY HAZARD AS FOLLOWS: 1.) AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED. 2.) IN EVERY STORAGE AND CONSTRUCTION SHED. 3.) ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE SPECIAL
HAZARDS EXIST, SUCH AS THE STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS.
24 FACILITIES REQUIRED. SANITARY FACILITIES SHALL BE PROVIDED DURING CONSTRUCTION, REMODELING OR DEMOLITION
ACTIVITIES IN ACCORDANCE WITH THE PLUMBING CODE
25 MAINTENANCE OF MEANS OF EGRESS. REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION, DEMOLITION, REMODELING OR ALTERATIONS AND ADDITIONS TO ANY BUILDING
26 FIRE SAFETY DURING DEMOLITION. FIRE SAFETY DURING DEMOLITION SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF
THIS CODE AND THE APPLICABLE PROVISIONS OF CHAPTER 33 OF THE FIRE CODE.
GENERAL NOTES - DEMOLITION
1 SEE SPECIFICATION BOOK FOR MORE INFORMATION.
2 THE CONTRACTOR IS DIRECTED TO LOCAL CODES AND REGULATIONS, AND IS TO FAMILIARIZE HER/HIMSELF WITH ALL WORK RELATING TO DEMOLITION INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: DC CONSTRUCTION CODE CHAPTER 33 -
SAFEGUARDS DURING CONSTRUCTION.
3 DC CONSTRUCTION CODE 3309.1 PROVIDE FIRE EXTINGUISHERS AT EACH STAIRWAY AT ALL FLOOR LEVELS, IN EVERY STORAGE AND CONSTRUCTION SHED, ADDITIONAL PORTABLE FIRE EXTINGUISHERS REQUIRED WHERE SPECIAL HAZARDS EXIST.
4 DURING CONSTRUCTION, AUTOMATIC SPRINKLER SYSTEMS REQUIRED DURING CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS SHALL BE PROVIDED IN ACCORDANCE WITH DC CONSTRUCTION CODE 2018 CHAPTER 33.
5 IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS TO VISIT THE SITE PRIOR TO BID, AND FAMILIARIZE THEMSELVES WITH THE SCOPE OF WORK. ANY QUESTIONS, COMMENTS, OR CLARIFICATIONS SHALL BE ASKED IN
WRITING TO THE ARCHITECT PRIOR TO SUBMISSION OF BID.
6 DEMOLITION DRAWINGS AND SPECIFICATIONS ARE INTENDED TO PROVIDE A GUIDE FOR DEMOLITION WORK IN THIS SPACE. THE CONTRACTOR SHALL PROCEED WITH CAUTION AND INVESTIGATE ALL EXISTING CONDITIONS THOROUGHLY. ANY DISCREPANCIES BETWEEN ASSUMED AND ACTUAL CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING
WITH THE WORK.
7 IF THE DEMOLITION WORK REVEALS CONDITIONS THAT CREATE A CONFLICT WITH PROPOSED NEW WORK, THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION BEFORE PROCEEDING WITH WORK.
8 PRIOR TO DEMOLITION, WALK THE PROJECT SITE AND RECORD EXISTING CONDITIONS. PREPARE A LOG WITH NOTATIONS AND PHOTOGRAPHS FOR SUBMISSION TO THE OWNER. FOCUS PARTICULAR ATTENTION ON AREAS THAT WILL REMAIN AT THE COMPLETION OF THE PROJECT. AREAS OF ATTENTION CAN INCLUDE BUT ARE NOT LIMITED TO; ELEVATOR CABS AND SILLS, ELEVATOR DOORS AND FRAMES, PERIMETER WINDOWS AND WINDOW SILLS, PERIMETER BLINDS AND BLIND POCKETS. WALK THE PROJECT SITE WITH THE OWNER, CONSTRUCTION MANAGER TO REVIEW DEFICIENCY LOG PREPARED AND REVIEW ALL ITEMS THAT ARE DAMAGED PRIOR TO THE START OF DEMOLITION. FAILURE TO DO SO, WILL RESULT IN THE ASSUMPTION THAT THE EXISTING TO REMAIN CONSTRUCTION WAS DAMAGED DURING THE COURSE OF CONSTRUCTION AND WILL BE REQUIRED TO BE RESTORED AT
THE END OF THE PROJECT.
9 ALL DEMOLISHED ITEMS THAT ARE NOT SHOWN TO BE REUSED ARE TO BE OFFERED TO THE BUILDING OWNER PRIOR TO REMOVAL FROM THE SITE. IF BUILDING OWNER DOES NOT WANT ANY OF THE DEMOLISHED ITEMS, CONTRACTOR IS RESPONSIBLE FOR
DISPOSAL OF THE ITEMS.
10 PROTECT ALL EXISTING CONSTRUCTION TO REMAIN. ALL DAMAGE TO EXISTING CONSTRUCTION SHALL BE REPAIRED BY
CONTRACTOR AT NO ADDITIONAL COST TO TENANT, LANDLORD, OR ARCHITECT.
11 GENERAL CONTRACTOR TO FLASH PATCH ALL FLOORS AS REQUIRED TO RESTORE CONCRETE FLOORING TO LIKE NEW AND LEVEL
CONDITION TO SATISFY ALL ASSEMBLY AND INSTALLATION REQUIREMENTS.
12 ALL MISCELLANEOUS NAILS, HANGERS, STAPLES, WIRES, AND WIRE CONDUIT THAT ARE NOT REUSED IN THE NEW SCOPE OF WORK
SHALL BE REMOVED.
FILE INFORMATION
SHEET NAME
MEP CONSULTANT:
ISSUES
SEAL / SIGNATURE
CLIENT
CONSULTANTS
© 2022 OTJ Architects, Inc.
Project No:
Drawn By:
Checked By:
DESCRIPTION
REVISION
NUMBER DATE
SCALE
Project Phase:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws an regulations of the
District of Columbia. I have pemvrsonally prepared, or directly supervised the development of, the architectural designs include in this application.
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
1/8" = 1'-0"
BIM 360://Studio 2 - Test Fits - R20/S02_11728.00_550 12th St, SW_NIGC_ 9th Floor_R20.rvt
NATIONAL INDIAN GAMING COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
A109
DEMOLITION PLAN
1110 NORTH GLEBE RD., Ste 300
GHT LIMITED CONSULTING
ENGINEERS
NIGC - 9TH FLOOR
11728.00
JM
MSC
ARLINGTON, VA 22201
P: 703.243.1200
50% DID REVIEW 1 7/27/23
100% DID REVIEW 2 8/22/23
50% CD SET 3 9/27/23
95% CD SET 4 10/26/23
#7
#6
#5
#1
#2
#3
#4
EXISTING LIGHT FIXTURE TO BE REMOVED.
OTHER FIXTURES SHOWN SIMILARLY.
EXISTING CEILING GRID SYSTEM TO BE
REMOVED & SALVAGED FOR RE-USE / RE-
INSTALLATION. 50% OF CUT TILES TO BE
SALVAGED AS WELL. GC TO COORDINATE
WITH ARCHITECT POST CEILING INSPECTION
ON WETHER RE-USE IS FEASIBLE.
EXISTING DRYWALL CEILING TO BE REMOVED
EXISTING CEILING GRID SYSTEM TO REMAIN
D/D1 D2
N.I.C.
C
D1D1D1
D1D1D1
D1D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1
D
DD
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
C
D D
D D
D
D
D
D
D
D
D
DD
D
D
D
D1
D
D
D
D D D
D D
D
D D D D DD
D D D D DD
D1 D D1 D D
D
D D D DD
D D D DD
D1
D
D D DD D D
D D DD D D
D
D
D
E
E
E
D
D D
D
D
D
D
D
DD D D
D
D
D
D
D
D D
D
D
D
E
D
E
D
E
D
E
D
E
D
E
D
D
D
D
DD
D D
E
E
D
DD D D
DDD
D
D
DD
D
DD
DD
DDE
DD
EE
EE
E1 E1 E1
D1 D1
D1
D1
D D
D D
D D
D2
D2
D2 D2
D2D2
DC1
DC1
FILE INFORMATION
SHEET NAME
MEP CONSULTANT:
ISSUES
SEAL / SIGNATURE
CLIENT
CONSULTANTS
© 2022 OTJ Architects, Inc.
Project No:
Drawn By:
Checked By:
DESCRIPTION
REVISION
NUMBER DATE
SCALE
Project Phase:
I am responsible for determining that the architectural designs included in this application are in compliance with all laws an regulations of the
District of Columbia. I have pemvrsonally prepared, or directly supervised the development of, the architectural designs include in this application.
580 WATER ST SW, SUITE 300
WASHINGTON, DC 20024
P: 202.621.1000
1/8" = 1'-0"
BIM 360://Studio 2 - Test Fits - R20/S02_11728.00_550 12th St, SW_NIGC_ 9th Floor_R20.rvt
NATIONAL INDIAN GAMING COMMISSION
550 12TH ST, SW
WASHINGTON, DC 20024
A110
DEMOLITION RCP PLAN
1110 NORTH GLEBE RD., Ste 300
GHT LIMITED CONSULTING
ENGINEERS
NIGC - 9TH FLOOR
11728.00
JM
MSC
ARLINGTON, VA 22201
P: 703.243.1200
GENERAL NOTES - DEMOLITION
13 CONTRACTOR SHALL REMOVE ALL MATERIALS ABOVE CEILING NOT SPECIFICALLY INDICATED TO REMAIN. ALL UNUSED WIRING, CABLES, CONDUIT, ETC. SHALL BE REMOVED AND STRIPPED BACK TO ORIGINAL SOURCE. THIS INCLUDES DATA CABLING THAT WILL
NOT BE REUSED.
14 ALL ABANDONED TELE/DATA RUNS AND TERMINATIONS SHALL BE REMOVED (REMOVE BOX AND COVER PLATE, PATCH WALL TO
LIKE-NEW CONDITION).
15 ALL ABANDONED ELECTRICAL OUTLETS SHALL HAVE THE BOX REMOVED TO THE PANEL. REMOVE BOX AND COVER PLATE, PATCH
WALL TO LIKE-NEW CONDITION.
16 REMOVE ALL FLOOR FINISHES, WALL COVERINGS AND SPECIALTY FINISHES, AND WALL BASE UNLESS OTHERWISE NOTED IN AREAS OF NEW CONSTRUCTION. PREPARE WALL, FLOOR, AND CEILING SURFACES FOR NEW FINISH AS SPECIFIED. BASE BID SHALL
INCLUDE ALL NECESSARY FLOOR PREP WORK TO ACCEPT NEW SPECIFIED FLOOR FINISHES.
17 PREPARE WALL, FLOOR, AND CEILING SURFACES FOR NEW FINISH AS SPECIFIED.
18 SALVAGE ALL DOORS, FRAMES, AND HARDWARE FOR REUSE UNLESS NOTED OTHERWISE.
19 ALL CEILINGS ARE TO REMAIN UNLESS NOTED OTHERWISE ON THE DEMOLITION OR REFLECTED CEILING PLANS.
20 ANY EXISTING BLINDS SHALL BE BOUND AND WRAPPED DURING DEMOLITION AND CONSTRUCTION, UNLESS SPECIFICALLY NOTED
TO BE REMOVED.
21 GENERAL CONTRACTOR SHALL RETAIN ALL WASTE HAULING TICKETS AND RETAIN NO LESS THAN 50% OF NONHAZARDOUS CONSTRUCTION WASTE WHICH SHALL BE DIVERTED FROM DISPOSAL BY RECYCLING OR SALVAGE OF CONSTRUCTION MATERIALS
AND WASTE IBC SECTION 503
22 GENERAL CONTRACTOR SHALL RETAIN ALL WASTE HAULING TICKETS AND RETAIN NO LESS THAN 50% OF NONHAZARDOUS CONSTRUCTION WASTE WHICH SHALL BE DIVERTED FROM DISPOSAL BY RECYCLING OR SALVAGE OF CONSTRUCTION MATERIALS
AND WASTE AS STATED IN THE 2013 DC GREEN CONSTRUCTION SECTION 503
23 STRUCTURES UNDER CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL BE PROVIDED WITH NO FEWER THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH SECTION 906 AND SIZED FOR NOT LESS THAN ORDINARY HAZARD AS FOLLOWS: 1.) AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED. 2.) IN EVERY STORAGE AND CONSTRUCTION SHED. 3.) ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE SPECIAL
HAZARDS EXIST, SUCH AS THE STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS.
24 FACILITIES REQUIRED. SANITARY FACILITIES SHALL BE PROVIDED DURING CONSTRUCTION, REMODELING OR DEMOLITION
ACTIVITIES IN ACCORDANCE WITH THE PLUMBING CODE
25 MAINTENANCE OF MEANS OF EGRESS. REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION, DEMOLITION, REMODELING OR ALTERATIONS AND ADDITIONS TO ANY BUILDING
26 FIRE SAFETY DURING DEMOLITION. FIRE SAFETY DURING DEMOLITION SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF
THIS CODE AND THE APPLICABLE PROVISIONS OF CHAPTER 33 OF THE FIRE CODE.
GENERAL NOTES - DEMOLITION
1 SEE SPECIFICATION BOOK FOR MORE INFORMATION.
2 THE CONTRACTOR IS DIRECTED TO LOCAL CODES AND REGULATIONS, AND IS TO FAMILIARIZE HER/HIMSELF WITH ALL WORK RELATING TO DEMOLITION INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: DC CONSTRUCTION CODE CHAPTER 33 -
SAFEGUARDS DURING CONSTRUCTION.
3 DC CONSTRUCTION CODE 3309.1 PROVIDE FIRE EXTINGUISHERS AT EACH STAIRWAY AT ALL FLOOR LEVELS, IN EVERY STORAGE AND CONSTRUCTION SHED, ADDITIONAL PORTABLE FIRE EXTINGUISHERS REQUIRED WHERE SPECIAL HAZARDS EXIST.
4 DURING CONSTRUCTION, AUTOMATIC SPRINKLER SYSTEMS REQUIRED DURING CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS SHALL BE PROVIDED IN ACCORDANCE WITH DC CONSTRUCTION CODE 2018 CHAPTER 33.
5 IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS TO VISIT THE SITE PRIOR TO BID, AND FAMILIARIZE THEMSELVES WITH THE SCOPE OF WORK. ANY QUESTIONS, COMMENTS, OR CLARIFICATIONS SHALL BE ASKED IN
WRITING TO THE ARCHITECT PRIOR TO SUBMISSION OF BID.
6 DEMOLITION DRAWINGS AND SPECIFICATIONS ARE INTENDED TO PROVIDE A GUIDE FOR DEMOLITION WORK IN THIS SPACE. THE CONTRACTOR SHALL PROCEED WITH CAUTION AND INVESTIGATE ALL EXISTING CONDITIONS THOROUGHLY. ANY DISCREPANCIES BETWEEN ASSUMED AND ACTUAL CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING
WITH THE WORK.
7 IF THE DEMOLITION WORK REVEALS CONDITIONS THAT CREATE A CONFLICT WITH PROPOSED NEW WORK, THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION BEFORE PROCEEDING WITH WORK.
8 PRIOR TO DEMOLITION, WALK THE PROJECT SITE AND RECORD EXISTING CONDITIONS. PREPARE A LOG WITH NOTATIONS AND PHOTOGRAPHS FOR SUBMISSION TO THE OWNER. FOCUS PARTICULAR ATTENTION ON AREAS THAT WILL REMAIN AT THE COMPLETION OF THE PROJECT. AREAS OF ATTENTION CAN INCLUDE BUT ARE NOT LIMITED TO; ELEVATOR CABS AND SILLS, ELEVATOR DOORS AND FRAMES, PERIMETER WINDOWS AND WINDOW SILLS, PERIMETER BLINDS AND BLIND POCKETS. WALK THE PROJECT SITE WITH THE OWNER, CONSTRUCTION MANAGER TO REVIEW DEFICIENCY LOG PREPARED AND REVIEW ALL ITEMS THAT ARE DAMAGED PRIOR TO THE START OF DEMOLITION. FAILURE TO DO SO, WILL RESULT IN THE ASSUMPTION THAT THE EXISTING TO REMAIN CONSTRUCTION WAS DAMAGED DURING THE COURSE OF CONSTRUCTION AND WILL BE REQUIRED TO BE RESTORED AT
THE END OF THE PROJECT.
9 ALL DEMOLISHED ITEMS THAT ARE NOT SHOWN TO BE REUSED ARE TO BE OFFERED TO THE BUILDING OWNER PRIOR TO REMOVAL FROM THE SITE. IF BUILDING OWNER DOES NOT WANT ANY OF THE DEMOLISHED ITEMS, CONTRACTOR IS RESPONSIBLE FOR
DISPOSAL OF THE ITEMS.
10 PROTECT ALL EXISTING CONSTRUCTION TO REMAIN. ALL DAMAGE TO EXISTING CONSTRUCTION SHALL BE REPAIRED BY
CONTRACTOR AT NO ADDITIONAL COST TO TENANT, LANDLORD, OR ARCHITECT.
11 GENERAL CONTRACTOR TO FLASH PATCH ALL FLOORS AS REQUIRED TO RESTORE CONCRETE FLOORING TO LIKE NEW AND LEVEL
CONDITION TO SATISFY ALL ASSEMBLY AND INSTALLATION REQUIREMENTS.
12 ALL MISCELLANEOUS NAILS, HANGERS, STAPLES, WIRES, AND WIRE CONDUIT THAT ARE NOT REUSED IN THE NEW SCOPE OF WORK
SHALL BE REMOVED.
DEMOLITION LEGEND
100% DID REVIEW 2 8/22/23
50% CD SET 3 9/27/23
95% CD SET 4 10/26/23
100% CD SET 6 11/20/23
PERMIT & PRICING 7 01/04/24
KEY NOTES - DEMOLITION CEILING
DC1 GC TO DEMO EXISTING DOWNLIGHTS AT THIS LOCATION. SALVAGE DOWNLIGHTS FOR RE-USE / RELOCATION.
#7
#6
#5
#1
#2
#3
#4
NEW PARTITIONS, REFER TO PARTITION
TYPES SHEET A002 FOR ADDITIONAL
INFORMATION
EXISTING PARTITION TO REMAIN NEW MILLWORK SHELVING OR
UPPER CABINETS. SEE ELEVATIONS
AND DETAILS FOR ADDITIONAL
INFORMATION.
N.I.C.
NEW DOOR. SEE DOOR AND
HARDWARE INFORMATION SHEETS
FOR ADDITIONAL INFORMATION.
EXISTING DOOR TO REMAIN. SEE
DOOR AND HARDWARE
INFORMATION SHEETS FOR
ADDITIONAL INFORMATION.
CHIEF OF
STAFF
OGC EXEC.
ADMIN
RECEPTION
CHIEF OFFICER
COPY ROOM
EXISTING LAN
MEDIA
WORKROOM
CHAIR OFFICE
VICE CHAIR
(COMMISSION)
COMMISSIONER
(COMMISSION)
COMM. COPY /
STORAGE
ROOM
EXEC. ADMIN.
OFFICE
BREAK ROOM
ASST. GC
OFFICE
IT…
This is the start of the file's text. The full file is on GovTribe.