1. APPLICANT/RESPONSIBLE PARTY:
CITY OF WILLIAMSPORT
1500 W 3RD STREET
WILLIAMSPORT, PA 17701
PHONE: 570.326.4684
2. LANDOWNER:
· CITY OF WILLIAMSPORT
1500 W 3RD STREET
WILLIAMSPORT, PA 17701
3. PROJECT LOCATION:
WILLIAMSPORT, PA 17701
CITY OF WILLIAMSPORT, LYCOMING COUNTY
LOCATED ALONG THE SOUTH SIDE OF BLAINE STREET, APPROXIMATELY 200 FEET EAST OF THE INTERSECTION OF BLAINE STREET AND
NEWCOMER AVENUE.
4. PROJECT NARRATIVE:
5. THE CITY OF WILLIAMSPORT IS PROPOSING TO CONSTRUCT A NEW OUTFIELD FENCE AND BATTER'S EYE STRUCTURE AT THE HISTORICAL
BOWMAN FIELD. THE PROJECT WILL INCLUDE STORMWATER MANAGEMENT AND OTHER SITE FEATURES.
6. SOURCE OF TITLE:
DB: 239, PG: 471
PARCEL No. 70-013-302
7. NO EXISTING WETLANDS HAVE BEEN IDENTIFIED BY THE NATIONAL WETLANDS INVENTORY WEBSITE OR BY FIELD OBSERVATION.
8. ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY'S FLOOD INSURANCE RATE MAP (42081C0431G), THE PROJECT SITE IS
LOCATED WITHIN THE AREA WITH REDUCED FLOOD RISK DUE TO LEVEE FOR THE 100-YEAR FLOODPLAIN.
9. THE PROJECT WILL BE SERVED BY PUBLIC SANITARY SEWER AND PUBLIC WATER.
10. LIMIT OF DISTURBANCE: 0.85 ACRES
GENERAL NOTES
1-800-242-1776
PE
NN
SY
LV
ANIA ONE CALL SYSTEM
, INC
STOP
- CA L L BE FORE YOU
D I G
PENNSYLVANIA ONE CALL
1.
LIVIC CIVIL HAS REQUESTED LINE AND UTILITY INFORMATION FROM THE
PA ONE CALL SYSTEM (POCS)
2.
POCS SERIAL NUMBER: 20242530680
DATE: SEPTEMBER 9, 2024
3. THE FOLLOWING FACILITY OWNERS HAVE INDICATED THROUGH POCS
THAT THEY HAVE FACILITIES IN THE PROJECT AREA:
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
WILLIAMSPORT SANITARY AUTHORITY
253 W FOURTH STREET
WILLIAMSPORT, PA 17701
NOAH CAPUTO
NCAPUTO@WMWA-WSA.ORG
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
COMCAST
336 PENN STREET
WILLIAMSPORT, PA 17701
TIM CRISWELL
TIMOTHY_CRISWELL@CABLE.COMCAST.COM
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
WILLIAMSPORT MUNICIPAL WATER
AUTHORITY
253 W FOURTH STREET
WILLIAMSPORT, PA 17701
IAN MOWATT
IMOWATT@WMWA-WSA.ORG
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
PPL ELECTRIC UTILITIES CORPORATION
437 BLUE CHURCH ROAD
PAXINOS, PA 17860
DOUG HAUPT
DLHAUPT@PPLWEB.COM
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
CITY OF WILLIAMSPORT
1500 W THIRD STREET
WILLIAMSPORT, PA 17701
JENNIFER DUDEK
JDUDEK@CITYOFWILLIAMSPORT.ORG
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
VERIZON PENNSYLVANIA LLC
40 S MERCER STREET
NEW CASTLE, PA 16101
TRICIA JACOBS
TRICIA.L.JACOBS@VERIZON.COM
UTILITY:
ADDRESS:
CONTACT:
EMAIL:
UGI UTILITIES INC
1 UGI DRIVE
WILKES-BARRE, PA 18711
AMANDA NIXON
ANIXON@UGI.COM
4.
BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA CALL 1-800-242-1776. PA ACT 287 OF 1974, AS AMENDED, REQUIRES THREE
(3) WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST.
CONSTRUCTION PLANS
BOWMAN FIELD OUTFIELD FENCE REPLACEMENT
CITY OF WILLIAMSPORT, LYCOMING COUNTY, PENNSYLVANIA
WILLIAMSPORT USGS QUAD
SCALE: AS SHOWN
PROJECT LOCATION MAP
FOR
N
2,000 2,000 4,000 FT0
HORIZONTAL SCALE: 1 INCH = 2,000 FEET
DRAWING INDEX
SHEET NUMBER SHEET TITLE
C001 COVER SHEET
C002 GENERAL INFORMATION
C101 EXISTING CONDITIONS & DEMOLITION PLAN
C201 SITE LAYOUT PLAN
C301 GRADING & STORMWATER PLAN
C302 GRADING & STORMWATER PLAN
C303 GRADING & STORMWATER PLAN
C304 GRADING & STORMWATER PLAN
C801 DETAILS
C802 STRUCTURAL DETAILS
C803 DETAILS
C804 DETAILS ALTERNATE 1
C805 DETAILS ALTERNATE 2
ES501 EROSION AND SEDIMENT CONTROL PLAN
ES502 E&S DETAILS
ES503 E&S NOTES
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C001
COVER SHEET
AUGUST 14, 2025
GENERAL CONSTRUCTION NOTES
1. EXISTING UTILITIES SHOWN ON THIS PLAN ARE BASED ON EXISTING MAPPING RECORDS AND/OR EVIDENCE OF ABOVE GROUND FACILITIES. SUE
HAS BEEN COMPLETED BY TRINITY SUBSURFACE, LLC. PAINT AND FLAGGING BASED ON THE SUE HAS BEEN LOCATED BY LIVIC CIVIL. THE EXACT LOCATION (HORIZONTAL & VERTICAL) OR ACCURACY THERE OF IS NOT GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING DEPTHS AND LOCATIONS OF ANY AND ALL UTILITIES WHICH FALL WITHIN OR ADJACENT TO THE LIMITS OF WORK. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING UTILITIES AND MAINTAIN UNINTERRUPTED SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATELY REARING ANY DAMAGED UTILITY THAT OCCURS DURING CONSTRUCTION, AT THEIR EXPENSE. THE CONTRACTOR IS REQUIRED TO COMPLETE THEIR UTILITY NOTIFICATIONS PER STATE LAW AND FOLLOW ANY AND ALL REGULATIONS.
2. THE CONTRACTOR IS TO NOTIFY OWNER/ENGINEER, IN WRITING, OF ANY UTILITY CONDITIONS AT THE SITE DIFFERING FROM THOSE INDICATED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH UTILITY OWNERS FOR THE ADJUSTMENT OR RELOCATION OF UTILITY SURFACE FEATURES, I.E. VALVE BOXES, UTILITY POLES, MANHOLES, ETC. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE RELOCATION OF CONFLICTING UTILITIES WHICH ARE A RESULT OF THESE IMPROVEMENTS.
3. THE OWNER SHALL PREPARE AND EXECUTE NECESSARY UTILITY EASEMENTS FOR PROPOSED RELOCATED UTILITIES IN ACCORDANCE WITH THE
REQUIREMENTS BY THE UTILITY OWNER.
4. EXISTING INFORMATION AND FEATURES SHOWN ON THIS SITE PLAN WERE TAKEN FROM A SURVEY PREPARED BY LIVIC CIVIL, DATED SEPTEMBER 9
& 18, 2024. THE FOLLOWING BENCH MARK HAS BEEN ESTABLISHED:
· BM1 - REBAR WITH LIVIC CAP
·· N: 392822.81 / E: 2162361.13 / ELEV: 525.77
5. THERE ARE NO NAVIGABLE STREAMS WITHIN THE PROJECT LIMITS.
6. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL BENCH MARKS AND CONTROL POINTS DURING CONSTRUCTION. CONTRACTOR SHOULD SET
ADDITIONAL CONTROL AS DEEMED APPROPRIATE.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE, REVIEW AND UNDERSTAND THE PLAN AND SPECIFICATIONS AND VERIFY ALL FIELD CONDITIONS, DIMENSIONS, DRAWINGS AND SPECIFICATIONS. ANY INCONSISTENCIES OR AMBIGUITIES IN THE DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE PROJECT'S OWNER IN WRITING. WORK COMPLETED BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES OR AMBIGUITIES, WITHOUT RECEIVING A RESPONSE FROM THE PROJECT'S OWNER, SHALL BE DONE AT THE
CONTRACTOR'S RISK.
8. THE CONTRACTOR SHALL COMPLETE THEIR UTILITY NOTIFICATIONS PER STATE LAW. CONTRACTOR IS TO NOTIFY OWNER/ENGINEER, IN WRITING, OF ANY UTILITY CONDITIONS AT THE SITE DIFFERING FROM THOSE INDICATED IN THE CONTRACT DOCUMENTS.
9. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL OTHER APPLICABLE TRADES (SITE, STRUCTURAL, PLUMBING, ELECTRICAL, ETC.) AS REQUIRED.
10. THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS, CODES AND REGULATIONS.
11. THE CONTRACTOR AND ANY SUBCONTRACTORS SHALL BE NOTIFIED THAT THEY ARE REQUIRED TO COMPLY WITH THE OCCUPATIONAL SAFETY
AND HEALTH ACT (OSHA), WHICH APPLY TO ALL PHASES OF CONSTRUCTION.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL, TRENCH SAFETY, COVERING, PLATING, SHEETING, SHORING AND SHORING
DESIGN AS NEEDED.
13. THIS PLAN IS NOT INTENDED TO REPRESENT ANY SUBSURFACE CONDITIONS, INCLUDING THE LOCATION OF BEDROCK OR OTHER GEOLOGICAL
CONDITIONS.
14. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE SAFE FLOW OF TRAFFIC DURING CONSTRUCTION. MAINTENANCE AND PROTECTION OF TRAFFIC DURING CONSTRUCTION SHALL BE IN ACCORDANCE WITH PennDOT PUBLICATION 213, "TEMPORARY TRAFFIC CONTROL GUIDELINES", AS
AMENDED.
15. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL REQUIRED NOTIFICATIONS AS SPECIFIED ON SUPPLIED PERMIT OF PERMIT PLANS. THIS INCLUDES MUNICIPALITIES, CONSERVATION DISTRICTS, PADEP, PennDOT AND OTHER REGULATORY AGENCIES.
16. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH UTILITY OWNERS FOR THE ADJUSTMENT OR RELOCATION OF UTILITY SURFACE FEATURES, I.E. VALVE BOXES, UTILITY POLES, MANHOLES, ETC. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE RELOCATION OF
CONFLICTING UTILITIES WHICH ARE A RESULT OF THESE IMPROVEMENTS.
17. CONSTRUCTION IS TO BE BASED ON ACTUAL FIELD STAKING OF IMPROVEMENTS BY A REGISTERED PROFESSIONAL ENGINEER. ANY DEVIATIONS
FROM THE STAKEOUT OR PLAN SHALL NOT BE PERMITTED WITHOUT APPROVAL.
18. THE CONTRACTOR SHALL ENSURE THAT POSITIVE DRAINAGE ACROSS ALL GRADED AREAS IS PROVIDED AND NO LOW SPOTS OR PONDING OCCUR
WITHIN THE LIMITS OF WORK UNLESS NATURALLY OCCURRING.
19. ALL EXISTING SIGNS, WHICH ARE DISTURBED DURING CONSTRUCTION, SHALL BE REINSTALLED IMMEDIATELY IN ACCORDANCE WITH APPLICABLE
FEDERAL, STATE, AND LOCAL REGULATIONS.
20. THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING MEASURES TO PREVENT DAMAGE TO ALL EXISTING FEATURES (TO REMAIN) WITHIN THE
PROJECT LIMITS AND ALONG ADJACENT PROPERTIES.
21. ALL AREAS WHICH ARE DISTURBED BY CONSTRUCTION, THAT ARE NOT TO BE PAVED OR HAVE SPECIFIC RESTORATION DETAILS, SHALL BE
RESTORED WITH A MINIMUM SIX (6") INCHES OF TOPSOIL AND SEEDED AND MULCHED.
22. PER PennDOT PUBLICATION 408, SECTION 409.3-CONSTRUCTION, NO BITUMINOUS PAVEMENT WILL BE PLACED BETWEEN NOVEMBER 1 AND MARCH 31, UNLESS AN EXTENSION OF THE PAVING SEASON IS GRANTED IN WRITING BY THE DISTRICT EXECUTIVE. ALL ASPHALT TO ASPHALT AND ASPHALT TO CONCRETE JOINTS SHALL BE SEALED IN ACCORDANCE WITH PUB 408, SECTION 409.3(k)3.
23. THE CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT THE WORKMEN AND THE PUBLIC SHALL BE PROTECTED FROM INJURY WHILE PROTECTING THE ADJOINING PROPERTY FROM DAMAGE. THE CONTRACTOR SHALL KEEP THE WORK AREA FREE OF ACCUMULATION OF WASTE MATERIAL. THE CONTRACTOR SHALL REMOVE ALL WASTE MATERIAL FROM THE PROJECT SITE, AS WELL AS ALL TOOLS, EQUIPMENT AND SURPLUS
MATERIAL.
24. ALL STORMWATER MANAGEMENT FACILITIES AND BMPs SHALL BE PERMANENT FIXTURES AND CANNOT BE MODIFIED WITHOUT PRIOR APPROVAL OF THE MUNICIPALITY AND COUNTY CONSERVATION DISTRICT. MODIFICATION, REMOVAL, FILING, LANDSCAPING, OR ALTERING ANY
STORMWATER FACILITY, BMP OR EASEMENT, SHALL BE OTHERWISE PROHIBITED.
25. THE DESIGNATION OF EXCESS WASTE DISPOSAL AND CONSTRUCTION STAGING AREAS, WHICH MAY BE REQUIRED BUT ARE NOT SHOWN ON THE PLANS, ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL CONSTRUCTION WASTE AND DEBRIS, INCLUDING EXCESS EXCAVATED MATERIAL, ASPHALT, CONCRETE, SCRAP WOOD, ETC., SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS MATERIAL SHALL BE DISPOSED OF OFF-SITE
IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
26. ALL TRENCHING SHALL OCCUR AS DESIGNATED BY THE PLANS. THE CONTRACTOR SHALL USE EQUIPMENT APPROPRIATE TO MAINTAIN A MAXIMUM PAVEMENT OPENING. IF A REVISED TRENCHING METHOD OR ALIGNMENT IS PROPOSED, THE CONTRACTOR SHALL NOTIFY THE PROJECT
ENGINEER AND OWNER IMMEDIATELY.
27. ALL EXCAVATIONS SHALL BE KEPT DRY TO PROTECT THEIR INTEGRITY. A SEDIMENT FILTER BAG OR EQUAL IMPLEMENTATION OF FILTERING IS
REQUIRED BEFORE DISCHARGING.
28. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONTINUOUSLY MAINTAINED, RELOCATED WHEN NECESSARY AND SHALL BE INSPECTED AFTER EVERY RAINFALL EVENT. THE CONTRACTOR SHALL CHECK SEEDED AREAS REGULARLY. THESE AREAS SHALL BE WATERED, FERTILIZED, RESEED AND MULCHED AS NECESSARY, TO OBTAIN STABILIZED COVER.
29. THE CONTRACTOR SHALL COMPLY WITH THE APPROVED EROSION AND SEDIMENT CONTROL PLAN. RE-GRADING, STRIPPING OF VEGETATION AND ANY OTHER WORK, SHALL BE DONE IN A MANNER TO MINIMIZE EROSION. EROSION AND SEDIMENT CONTROL BMPs REQUIRED BY THE CONSERVATION DISTRICT SHALL BE INSTALLED BY THE CONTRACTOR. SHOULD SEDIMENTATION OCCUR, IT IS THE RESPONSIBILITY OF THE ENTITY CAUSING THE SEDIMENTATION TO REMOVE IT FROM ANY AFFECTED AREAS. ANY DISTURBED AREAS SHALL BE STABILIZED IMMEDIATELY.
TEMPORARY VEGETATION AND/OR MULCHING MAY BE UTILIZED TO PROTECT EXPOSED CRITICAL AREAS DURING CONSTRUCTION. DUST CONTROL
MEASURES SHOULD BE EXERCISED DURING THE ENTIRETY OF CONSTRUCTION.
30. THE INFORMATION SHOWN ON THIS PLAN MAY HAVE ALSO BEEN RELEASED IN A DIGITAL DRAWING FORMAT. ONCE LIVIC CIVIL HAS RELEASED SUCH INFORMATION, WE TAKE NO RESPONSIBILITY OF ANY CHANGES THAT MAY OCCUR. THE ORIGINAL SEALED PLANS SHOULD BE REFERENCED TO ANY REPRODUCED MATERIAL THAT MAY BE VIEWED. ALSO ANY DIGITAL FILES OR DATA CONTAINED WITHIN, BEING USED WILL COME AT THE
RISK OF THE USER.
ABBREVIATIONS
BOTTOM OF CURB
HIGH POINT
TOP OF CURB
BOTTOM OF WALL
TOP OF WALL
TO BE REMOVED
BC
BW
HP
TBR
TC
TW
TYPTYPICAL
STORM SEWER/INLET
SANITARY SEWER
CONTOUR LINE-MAJOR
PROPERTY LINE
BUILDING SETBACK
CENTER LINE OF ROAD
PLAN TEXT
EXISTING
BUILDING LINE
EDGE OF PAVEMENT
CONCRETE CURB
CONCRETE SIDEWALK
SIGN
FENCE LINE
BENCHMARK
UNDERGROUND ELECTRIC
SEWER FORCE MAIN
GAS MAIN/VALVE
OVERHEAD UTILITIES & POLE
WATER MAIN/VALVE
PLAN TEXT PLAN TEXT
PROPOSED
RIGHT-OF-WAY LINE
EASEMENT LINE
GRAVEL
CONTOUR LINE-MINOR
X
EDGE OF WATER
G
S
FM
OH
UE
W
GUIDE RAIL
X
G
S
FM
OH
UE
W
LEGEND
100 100
DY
H DY
H
GV
FIRE HYDRANT
WV
0 0DATA/COMMUNICATION
WsB
NPDES PERMIT BOUNDARY NPDES
LIMIT OF DISTURBANCE LOD
SOIL BOUNDARY
SOIL DESIGNATOR
MANHOLE
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C002
GENERAL
INFORMATION
COMMUNICATIONS
JUNCTION
BOX
ELECTRIC
METER
ELECTRIC METER
ELECTRIC
METER
NO ID
PPL 19369 N39294
PPL 19370 N39297
PPL 19361 N39296
PPL 19361 N39299
PPL 19355 N39307
PPL 19342 N39299
BACK STOP
(TBR BY OTHERS)
15" HEMLOCK
(TBR BY OTHERS)
12" HEMLOCKS
(TBR BY OTHERS)20" HEMLOCK
(TBR BY OTHERS)
24" HEMLOCK
(TBR BY OTHERS)
SCAFFOLDING
(TBR BY OTHERS)
SCAFFOLDING
(TBR BY OTHERS)
6x6
(TYP)TBR
4" DIAMETER POST
WITH METAL BAND
TO FENCE (TYP) TBR
X X
X
X
X X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
XXXXXX
X
X
X
X
X X
X
X
X
X
X
X
XXXXXXX
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
XXXXXX
X
X
BLAINE ST.
NE
W
CO
M
ER
A
VE
15" ALLEY
H
AM
M
ON
D
PL
N/F
CITY OF WILLIAMSPORT
TP# 70-013-302
DB 239 PG 471
N /F
CO
M
M
ON
W
EA
LT
H
O F
PA
TP
-0
-1
N/F
DEASE, MARY M. ET AL
TP# 70-013-125
" A
LL
EY
N/F
WILLIAMS, RODNEY S. ET AL
TP# 70-013-129
N/F
LING LU
TP# 70-013-130 N/F
PAULHAMUS, LARRY
ET AL
TP# 70-013-130
N/F
PAULHAMUS, LARRY
ET AL
TP# 70-013-111 N/F
VICK, MICHAEL S.
TP# 70-013-110 N/F
McCLURE, WAYNE
J. ET AL
TP# 70-013-109
N/F
BOROSCO, JOSEPH
A. ET AL
TP# 70-013-108
N/F
BOROSCO, JOSEPH A.
ET AL
TP# 70-013-107
N/F
KENNEDY, TANYA Y.
ET AL
TP# 70-013-107
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
X
X
XX
X
X X
X
X
X
X
X
PPL 19376 N39266
PPL 19357
N39259
PPL 19345 N39255
INLET RIM 524.54'
(N) 12" RCP 520.15'
(E) 12" 520.09'
(S) 12" RCP 519.97'
INLET RIM 519.12'
(N) 12" RCP 515.78'
(S) 12" RCP 516.07'
INLET RIM 518.82'
(N) 6" SLCPP 516.97'
(S) 12" SLCPP 516.40'
INLET RIM 518.95'
(N) 6" SLCPP
(S) 6" SLCPP
INLET RIM 519.45'
(N) 8" SLCPP 517.58
(W) 6" SLCPP 517.65'
(S) 8" SLCPP 517.54'
IRRIGATION SYSTEM
WITH 6" LIDS
UE
UE
UE
UE
UE
UE
UE
UE
UE
OH
OH
OH
OH
UE
UE
UE
UE
UE
UE
UEUE
UE
UE
UE
OH
OH
UE
UE
UE
UE
UE
UE
UNKNOWN
UTILITY
X
X
SCORE
BOARD
S
S
S
S
S
S
S
S
S
S
S
S
S
START FENCE REMOVAL AT START OF 12' FENCE.
BULLPEN FENCE AND 8' FENCE TO REMAIN.
END FENCE REMOVAL AT END OF 12' FENCE.
BULLPEN FENCE AND 8' FENCE TO REMAIN.
X
X
X
X
X
20' WIDE WARNING TRACK
UNDERGROUND
COMMUNICATION
LINE
50' ROW
EDGE OF PAVEMENT
EDGE OF PAVEMENT
6" PVC
FIELD DRAIN
BENCHMARK
REBAR WITH LIVIC CAP
ELEV: 525.77
BULLPEN
BULLPEN
FENCING
(TBR BY OTHERS)
GRASS OUTFIELD
STADIUM
LIGHTS
FOUL POLE
TO BE REPLACED
FOUL POLE
TO BE REPLACED
STADIUM
LIGHTS
STADIUM
LIGHTS
LAYDOWN AREA
X X
X
X
X
X
X
X
X
X
X X
X
X X
X X
X X
X X
X X
X X
X X
X
XX
X
INSTALL TEMPORARY CHAINLINK
CONSTRUCTION FENCE
INSTALL TEMPORARY CHAINLINK
CONSTRUCTION FENCE
STADIUM
LIGHTS
PPL 19352 N39297
UE UE UE UE
SAWCUT CLEAN LINES IN
PAVEMENT TO INSTALL
STORM PIPE
AREA OF REMOVAL
LIMIT OF DEMOLITION
LEGEND
TO BE REMOVEDTBR
40 40 80 FT0
HORIZONTAL SCALE: 1 INCH = 40 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C101
EXISTING
CONDITIONS &
DEMOLITION PLAN
AUGUST 14, 2025
NOTES:
CONTRACTOR TO REMOVE ALL COMPONENTS OF OUTFIELD FENCE FROM END TO
END - WALL, POSTS, FENCE BOARDS, REAR SUPPORTS AND FOUNDATIONS.
BULL PEN FENCE AND FOUL POLES TO REMAIN IN PLACE AS IS.
FOUL POLES TO REMAIN AS IS.
CONTRACTOR SHALL HAVE ACCESS TO WARNING TRACK AREA BUT NOT GRASS
OUTFIELD.
CITY OF WILLIAMSPORT WILL REMOVE ALL MATERIALS, TEMPORARY FENCING,
ETC. BEYOND THE OUTFIELD FENCE
CITY OF WILLIAMSPORT TO REMOVE TREES WHERE SHOWN AS WELL AS THE
BACKSTOP.
BOX
ELECTRIC
METER
ELECTRIC
METER
ELECTRIC
METER NO ID
PPL 19369 N39294
PPL 19370 N39297
PPL 19361 N39296
PPL 19361 N39299
PPL 19355 N39307
PPL 19342 N39299
X X
X X
X
X
X X
X X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X
X
X
XXXXXXXX
X
X
X
X
X
X
X X
X
X
X
X
X
BLAINE ST.
NE
W
CO
M
ER
A
VE
15" ALLEY
H
AM
M
ON
D
PL
N/F
CITY OF WILLIAMSPORT
TP# 70-013-302
DB 239 PG 471
N /F
CO
M
M
ON
W
EA
LT
H
O F
PA
TP
-0
-1
N/F
DEASE, MARY M. ET AL
TP# 70-013-125
" A
LL
EY
N/F
WILLIAMS, RODNEY S. ET AL
TP# 70-013-129
N/F
LING LU
TP# 70-013-130
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-130
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-111 N/F
VICK, MICHAEL S.
TP# 70-013-110
N/F McCLURE, WAYNE J. ET AL
TP# 70-013-109
N/F
BOROSCO, JOSEPH A. ET AL
TP# 70-013-108
N/F
BOROSCO, JOSEPH A. ET AL
TP# 70-013-107 N/F
KENNEDY, TANYA Y. ET AL
TP# 70-013-107
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OHOH
X
X
X
X
X
X
X
X
X
PPL 19376 N39266
PPL 19357
N39259
PPL 19345 N39255
INLET RIM 524.54'
(N) 12" RCP 520.15'
(E) 12" 520.09'
(S) 12" RCP 519.97'
INLET RIM 518.82'
(N) 6" SLCPP 516.97'
(S) 12" SLCPP 516.40'
INLET RIM 518.95'
(N) 6" SLCPP
(S) 6" SLCPP
INLET RIM 519.45'
(N) 8" SLCPP 517.58
(W) 6" SLCPP 517.65'
(S) 8" SLCPP 517.54'
IRRIGATION SYSTEM WITH
6" LIDS
UE
UE
UE
UE
UE
UE
UE
OH
OH
OH
OH
OH
OH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
OH
OH
OH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UNKNOWN
UTILITY
X
X
SCORE
BOARD
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
X
X
X
X
X X
X
UNDERGROUND
COMMUNICATION
LINE
50' ROW
EDGE OF PAVEMENT
EDGE OF PAVEMENT
6" PVC
FIELD DRAIN
BENCHMARK
REBAR WITH LIVIC CAP
ELEV: 525.77
STADIUM
LIGHTS
STADIUM
LIGHTS
STADIUM
LIGHTS
LAYDOWN AREA
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
XX
X
INSTALL TEMPORARY CHAINLINK
CONSTRUCTION FENCE
INSTALL TEMPORARY CHAINLINK
CONSTRUCTION FENCE
STADIUM
LIGHTS
PPL 19352 N39297
UE UE UE UE UE
X X
X X
X
X
X
X
X
X
X
X
XXXXXXXX
TIE PROPOSED 12' FENCE
INTO EXISTING 8' FENCE
AT TRANSITION
TIE EXISTING BULLPEN FENCE
INTO PROPOSED FENCE
TIE EXISTING BULLPEN FENCE
INTO PROPOSED FENCE
TIE PROPOSED UNDERDRAIN INTO
EXISTING FIELD UNDERDRAIN.
FIELD VERIFY LOCATION AND
DEPTH OF EXISTING UNDERDRAIN
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
LO
D
LO
D LOD
LOD
LOD
LOD
LOD
LOD LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LODLOD
LODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
CONCRETE CURB
TOP OF CURB: 521.90
TIE PROPOSED 12' FENCE INTO
EXISTING 8' FENCE AT TRANSITION
PAVEMENT
RESTORATION
8" UNDERDRAIN
CONNECT UNDERDRAIN
TO 12" NYLOPLAST
YARD DRAIN
TYPE M INLET
12" SLCPP
12" SLCPP
TYPE M INLET
CUT AND CONNECT EXISTING
PIPES INTO NEW INLET
PROTECT
UNDERGROUND LINES
PROTECT
UNDERGROUND LINES
BATTER'S EYE CENTERED ON LINE OF SIGHT
FROM HOME PLATE TO PITCHER'S MOUND
(INSTALL PER DETAIL SHEET C801/C802)
(ALTERNATE 1 - 80' WIDE X 40' TALL)
(ALTERNATE 2 - 60' WIDE X 36' TALL)
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
30 30 60 FT0
HORIZONTAL SCALE: 1 INCH = 30 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C201
SITE LAYOUT PLAN
AUGUST 14, 2025
BA
TT
ER
'S
SI
GHT
LIN
E
NOTES:
RELOCATE IRRIGATION SYSTEM IN FRONT OF NEW FENCE -
CONTRACTOR TO SALVAGE EXISTING SYSTEM, RESET IT IN
FRONT OF EXISTING FENCE AND MAKE ANY REQUIRED
RECONNECTIONS.
BOX
ELECTRIC
METER
ELECTRIC
METER
ELECTRIC
METER NO ID
PPL 19369 N39294
PPL 19370 N39297
PPL 19361 N39296
X X
X X
X
X
X X
X X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X
X
X
XXXXXXXX
X
X
X
X
X
X
X X
X
X
X
X
X
N/F
CITY OF WILLIAMSPORT
TP# 70-013-302
DB 239 PG 471
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
X
X
X
X
X
X
X
X
X
PPL 19376 N39266
PPL 19357
N39259
INLET RIM 524.54'
(N) 12" RCP 520.15'
(E) 12" 520.09'
(S) 12" RCP 519.97'
INLET RIM 519.45'
(N) 8" SLCPP 517.58
(W) 6" SLCPP 517.65'
(S) 8" SLCPP 517.54'
IRRIGATION SYSTEM WITH
6" LIDS
UE
UE
UE
UE
OH
OH
OH
OH
OH
OH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
OH
OH
UE
UE
UE
UE
UE
UE
UE
UNKNOWN
UTILITY
X
X
SCORE
BOARD
S
S
S
S
S
S
S
S
S
S
S
S
X
X
X
X
X X
X
UNDERGROUND
COMMUNICATION
LINE
6" PVC
FIELD DRAIN
BENCHMARK
REBAR WITH LIVIC CAP
ELEV: 525.77
STADIUM
LIGHTS
STADIUM
LIGHTS
STADIUM
LIGHTS
LAYDOWN AREA
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
STADIUM
LIGHTS
PPL 19352 N39297
UE UE UE UE UE
X X
X X
X
X
X
X
X
X
X
X
XXXXXXXX
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
LO
D
LO
D LOD
LOD
LOD
LOD
LOD
LOD LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LODLOD
LODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
PAVEMENT
RESTORATION
8" UNDERDRAIN
CONNECT UNDERDRAIN
TO 12" NYLOPLAST
YARD DRAIN
TYPE M INLET
12" SLCPP
12" SLCPP
TYPE M INLET
CUT AND CONNECT EXISTING
PIPES INTO NEW INLET
PROTECT
UNDERGROUND LINES
PROTECT
UNDERGROUND LINES
BATTER'S EYE CENTERED ON LINE OF SIGHT
FROM HOME PLATE TO PITCHER'S MOUND
(INSTALL PER DETAIL SHEET C801/C802)
(ALTERNATE 1 - 80' WIDE X 40' TALL)
(ALTERNATE 2 - 60' WIDE X 36' TALL)
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
UNDERDRAIN TO I-3 PROFILE
1.
1.
0.
1.
1.
1.
1.
1.
2.
2.
2.
2.
2.
1.
1.
1.
1.
1.
0.
0.
0.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0+00 1+00 2+00 3+00 4+00 5+00 6+00 6+70.90
I-2 T/G:521.60
INV IN:518.05 12" SLCPP NW
INV OUT:518.05 12" SLCPP SE
YD-1
T/G:521.11
INV IN:518.45 8" PVC N
INV IN:518.45 8" PVC S
INV OUT:518.28 12" SLCPP SE
I-1 T/G:522.04
INV IN:517.81 12" SLCPP NW
113' OF 12" SLCPP @ 0.20%
YD-3
T/G:521.16
INV IN:518.71 8" PVC NW
INV OUT:518.71 8" PVC S YD-2
T/G:521.13
INV IN:518.61 8" PVC N
INV OUT:518.61 8" PVC S
112' OF 12" SLCPP @ 0.21%
YD-4
T/G:521.18
INV IN:518.82 8" PVC NW
INV OUT:518.82 8" PVC SE
YD-5
T/G:521.25
INV IN:518.90 8" PVC NW
INV OUT:518.90 8" PVC SE
YD-6
T/G:521.31
INV IN:518.96 8" PVC W
INV OUT:518.96 8" PVC SE
YD-7
T/G:521.40
INV IN:519.05 8" PVC W
INV OUT:519.05 8" PVC E
YD-8
T/G:521.46
INV IN:519.11 8" PVC W
INV OUT:519.11 8" PVC E
YD-9
T/G:521.80
INV OUT:519.44 8" PVC E
8" UNDERDRAIN
SEE C803 FOR DETAILS
FIELD VERIFY DEPTH AND LOCATION
OF EXISTING UNDERGROUND
COMMUNICATION LINE
EXISTING SANITARY SEWER
FIELD VERIFY DEPTH
EXISTING UNDERGROUND ELECTRIC
AND COMMUNICATION LINE
FIELD VERIFY DEPTH
30 30 60 FT0
HORIZONTAL SCALE: 1 INCH = 30 FEET
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C301
GRADING &
STORMWATER
PLAN
AUGUST 14, 2025
30 30 60 FT0
HORIZONTAL SCALE: 1 INCH = 30 FEET
N
6 6 12 FT0
VERTICAL SCALE: 1 INCH = 6 FEET
X X
X X
X X
X X
X X
X X
XX
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXX
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
N/F
LING LU
TP# 70-013-130
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
20' WIDE WARNING TRACK
6" PVC
FIELD DRAIN
521.34
521.25
521.25
521.38
521.34
521.33
BULLPEN
GRASS OUTFIELD
STADIUM LIGHTS
STADIUM LIGHTS
X X
X X
X X
X X
X
XX
X
X
X
X
X
X
UE UE UE UE UE UE UE UE UE UE UE UE UE UE
521.26
521.31
XXXXXXXXXXXXXXX
TIE PROPOSED 12' FENCE INTO
EXISTING 8' FENCE AT TRANSITION
TIE EXISTING BULLPEN FENCE
INTO PROPOSED FENCE
A-A
CONCRETE CURB
TOP OF CURB: 521.90
8" UNDERDRAIN
4" UNDERDRAIN
(ALTERNATE 3)
EXTENT OF GRADING
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
-1 .2
-0.8%
-1 .0
YD-9
521.13
521.13
521.05
521.22 521.08
ELECTRIC METER
ELECTRIC METER
PPL 19342 N39299
X
XXXXXXX
TP# 70-013-130
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-130
X
X X
X
UE
UE
UE
UEUE
UE UE UE UE
UE
UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
X
X
X
X
XSCORE
BOARD
X X
X X
X X
X X
UE UE UE
X
XXXXXXX
CONDUIT TO BE REMOVED FROM
EXISTING FENCE AND REATTACHED
TO PROPOSED CHAINLINK FENCE
-1 7.
5%
-6 .5
-5 .1
YD-8
521.13
521.51
10 10 20 FT0
HORIZONTAL SCALE: 1 INCH = 10 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C302
STORMWATER
PLAN
PPL 19352 N39297
PLATFORM
PITCH
CLOCK
FLAG POLE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
XX
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-130
X
X
X
X
X
UE
UE
UE UE UE
UE
UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
X
X
X
X
X
6" PVC
FIELD DRAIN
521.26
521.31
521.17
521.26
521.14
521.16
521.25
521.21
521.17
521.18
521.15
521.12
521.19
521.20
521.22
521.22
521.33
STADIUM LIGHTS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
521.16
ELECTRIC METER
ELECTRIC METER
SCORE
BOARD
STADIUM LIGHTS
PPL 19342 N39299
UE
UE
UE
UE
UE
UE
UE
UE
UE
521.26
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
XXX
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A-A
CONDUIT TO BE REMOVED FROM
EXISTING FENCE AND REATTACHED
TO PROPOSED CHAINLINK FENCE
8" UNDERDRAIN
CONCRETE CURB
TOP OF CURB: 521.90
BATTER'S EYE CENTERED ON LINE OF SIGHT
FROM HOME PLATE TO PITCHER'S MOUND
(INSTALL PER DETAIL SHEET C801/C802)
(ALTERNATE 1 - 80' WIDE X 40' TALL)
(ALTERNATE 2 - 60' WIDE X 36' TALL)
4" UNDERDRAIN
(ALTERNATE 3)
EXTENT OF GRADING
-17.5%
-2 2.
3% -2 5.
7%
-2 2.
5%
-1 8.
2%
-1 5.
9%
-1 5.
8%
-1 2.
4%
-13.9%
-10.1%
-6.5%
-5 .1
-1.2%
YD-2
YD-3
YD-4
YD-5
YD-6
YD-7
YD-8
521.13
521.13
521.13
521.13
521.13
521.13
521.13
521.13
521.22
521.51
521.08
522.14
522.51
522.67 522.33
522.61
521.74
521.63
10 10 20 FT0
HORIZONTAL SCALE: 1 INCH = 10 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C303
STORMWATER
JUNCTION BOX
ELECTRIC METER
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X
XXXXXXXXXXX
X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
INLET RIM 519.45'
(N) 8" SLCPP 517.58
(W) 6" SLCPP 517.65'
(S) 8" SLCPP 517.54'
IRRIGATION SYSTEM
WITH 6" LIDS
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UEUEUE
UEUE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UEUE
UE
UE
UE
UNKNOWN
UTILITY
UNDERGROUND
COMMUNICATION
LINE
6" PVC
FIELD DRAIN
521.25
521.21
521.27
521.28
521.35
521.32
521.35
521.19521.20 521.22
521.22
521.20
BULLPEN
STADIUM LIGHTS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X
STADIUM LIGHTS
521.17
X
X X
X X
X X
X X
X X
X
XXXXXXXXXXX
X
TIE EXISTING BULLPEN FENCE
INTO PROPOSED FENCE
TIE PROPOSED UNDERDRAIN INTO
EXISTING FIELD UNDERDRAIN.
FIELD VERIFY LOCATION AND
DEPTH OF EXISTING UNDERDRAIN
LOD
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
8" UNDERDRAIN
TIE PROPOSED 12' FENCE INTO
EXISTING 8' FENCE AT TRANSITION
CONCRETE CURB
TOP OF CURB: 521.90
4" UNDERDRAIN
(ALTERNATE 3)
EXTENT OF GRADING
REPLACE FOUL POLES WITH
POLES PROVIDED BY OWNER
-1 5.
9%
-1 5.
8%
-1 2.
4%
-1 3.
9%
-1 0.
1%
-2.2%
-2.8%
-5 .9
YD-1
YD-2YD-3
521.13 521.13
521.13
521.74 521.63
520.81
521.29
521.13
I-2
10 10 20 FT0
HORIZONTAL SCALE: 1 INCH = 10 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C304
STORMWATER
MATERIALS
A. FABRIC - VINYL COATED STEEL CHAIN LINK FABRIC SHALL BE FURNISHED IN ACCORDANCE WITH ASTM F-668-TYPE
2B. THE STEEL CORE WIRE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A-641-71A. THE COLOR SHALL BE BLACK, A.1-TYPE-STANDARD INDUSTRIAL, 2"X1/8" MESH, 9-GUAGE, 0.14" CORE WIRE DIA., 1290 LB. BREAKLOAD.
B. FRAMING & FITTINGS - ALL STEEL PARTS SHALL BE HOT-DIPPED GALVANIZED AS PER ASTM, PRIOR TO VINYL COATING. THICKNESS OF VINYL COATING SHALL BE 10-14 MILS APPLIED BY FUSION BONDING.
24"
6"
72"
12'
8' SPACING O.C.
TENSION BAR
CONCRETE POST FOOTING
(TYP OF ALL POSTS)
BOTTOM SELVAGE
KNUCKLED
HOG RING
POST CAP (DOME TYPE)
ROUND END & CORNER POST
4" SCHEDULE 80
CHAIN LINK FABRIC
(TOP SELVAGE KNUCKLED)
LINE POST LOOP CAP
COILED SPRING
TENSION WIRE
LINE POST TIE
LINE POST
(ROUND OR "C")
TOP RAILTIE WIRE
CHAIN LINK FENCE - 12' HEIGHT
NOT TO SCALE
2" MESH 9-GA POLYMER COATED CHAIN
LINK FABRIC, COLOR TO BE BLACK;
KNUCKLED TOP & BOTTOM SELVAGES
KNUCKLE SELVAGE
1 5 8" TOP RAIL
1 5 8" MIDDLE RAIL
1 5 8" BOTTOM RAIL
24"
12' HEIGHT CHAINLINK
FENCE POST (TYP.)
FENCE PADDING
(INSTALLED BY OTHERS)
FENCE SECTION A-A
NOT TO SCALE
WARNING TRACK
CONCRETE PADDED FENCE POST
FOUNDATION, SEE DETAIL
NOTE:
PROVIDE 12" OVERLAP OF FABRIC
AASHTO NO. 57
COARSE AGGREGATE
8" HDPE SINGLE WALL
PERFORATED PIPE
CLASS 1
GEOTEXTILE FABRIC
6" 6"
UNDERDRAIN
NOT TO SCALE
12" MIN
COVER
FINISHED GRADE
12"
OVERLAP
8" HDPE SINGLE WALL
PERFORATED PIPE
CLASS 1
GEOTEXTILE FABRIC
12" MIN
COVER
6" WARNING
TRACK MIX (MIN.)
12"
8" EXPOSED @
BACK OF CURB
12" MIN
COVER
18"
12"
8"
24"
5% VARIES
INV: 518.19
ELEV: 521.13
VARIES
EXISTING PAVEMENT
SEE NOTE
PAVEMENT JOINT
NOT TO SCALE
REFERENCE BITUMINOUS PAVEMENT
NOTE
SAWCUT CLEAN, STRAIGHT EDGE IN EX PAVEMENT AND REMOVE
EX MATERIAL. INSTALL NEW PAVEMENT AGAINST EDGE,
FORMING A SMOOTH, FLUSH JOINT. SEAL WITH CRAFCO
ASPAHLT RUBBER TYPE 2 CRAFCO SUPERFLEX, OR EQUIVALENT.
1.5” (9.5MM) SUPERPAVE ASPHALT MIXTURE DESIGN, HMA
WEARING COURSE, PG.64-22, 0 TO 0.3 MILLION ESAL’S
4” (25MM) SUPERPAVE ASPHALT MIXTURE DESIGN, HMA
BINDING COURSE, PG.64-22, 0 TO 0.3 MILLION ESAL’S
6.0" 2A MODIFIED STONE SUBBASECOMPACTED SUBBGRADE
BITUMINOUS PAVEMENT
NOT TO SCALE
4" WIDE SAWN OR
TOOLED CONTROL JOINT,
2 12" MIN DEPTH
SEALANT, 1" DEPTH
8" WIDE PREFORMED EXPANSION
JOINT, FULL DEPTH OF CONCRETE SLAB
PROVIDE TOOLED EDGE
EXPANSION AND CONTROL JOINTS
NOT TO SCALE
NOTE:
SEE DRAWINGS AND SPECIFICATION FOR PLACEMENT OF
ISOLATION AND CONTROL JOINTS FOR CONCRETE.
CONCRETE
SUBBASE
FOUL POLES
(TO BE PROVIDED BY OWNER)
NOT TO SCALE
NOTES:
1. ALL FOUL POLE BASE FOUNDATIONS SHALL BE CAST-IN-PLACE CONCRETE, 3500 PSI
MIN. 28 DAY COMPRESSIVE STRENGTH CONCRETE WITH GRADE 60 REINFORCING STEEL.
2. IF WATER IS PRESENT IN EXCAVATED HOLE, REMOVE BEFORE POURING CONCRETE.
3. FOUNDATION EXCAVATION SHALL BE BY 24" AUGER IN UNDISTURBED OR PROPERLY
COMPACTED FILL PER SPECIFICATIONS.
4. FOUNDATION SHALL HAVE A MINIMUM ALLOWABLE END BEARING OF 2000 PSF.
FOUL POLES
(SEE DETAIL)
FINISHED GRADE
VERTICAL AND HORIZONTAL BARS SHALL
BE FIELD TIED. WELDING NOT PERMITTED.
SUPPORT REINFORCEMENT IN ITS PROPER
LOCATION FROM THE FORMWORK DURING
CONCRETE OPERATION.
2' BELOW FROST LINE
(4) ANCHOR BOLTS 1.25"
DIA. x 42" LONG x 6" HOOK
4-#8 x 8' (MIN) LONG
BARS EQUALLY SPACED
#3 TIES @ 16" O.C. MAX
3"
24"
DIAMETER
3"
TYP
6' - 0"
MINIMUM COVER TYP.
FOUL POLE FOUNDATIONS
NOT TO SCALE
BASE PLATE MOUNTING KIT
(SEE DETAIL)
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C801
DETAILS
3"
CLEAR
PIER FOOTING
(SHOWN AS 24" DIA.)
(6) #6 VERTICAL BARS
EQUALLY SPACED
#3 TIES AT
14" O.C.
EMBEDDED 4" SCH. 80
ASTM F1083 FENCE POST
EXISTING
GRADE
6' -6
M
IN
IM
U M
2'-0" SECTION a a
8" B
EL
O
W B
O T.
O F
FE
N
C E
PO
ST
DESIGN CRITERIA
CONCRETE: 4,000 PSI
REINFORCING: ASTM A615, GRADE 60
ALLOWABLE SOIL LATERAL PASSIVE PRESSURE: 250 PSF/FT
MAXIMUM SOIL LATERAL PRESSURE LIMIT: 1,500 PSF
4" SCH. 80 FENCE POST
(8'-0" MAX O.C. SPACING)
NOTES:
1. FOUNDATIONS SIZED FOR A 12' PADDED (SOLID) FENCE WITH A MAXIMUM
FENCE POST SPACING OF 8'-0" O.C.
DETAIL
TYPICAL PADDED FENCE
POST FOUNDATION
NO SCALE
B S1
10"
3"
CLEAR
PIER FOOTING
(SHOWN AS 60" DIA.)
(24) #7 VERTICAL BARS
EQUALLY SPACED
#3 TIES AT
14" O.C.
EMBEDDED
W16x67 COLUMN
EXISTING
GRADE
'-0
M
IN
IM
U M
5'-0"
SECTION a a
8" B
EL
O
W
BO
T.
O
F C
O
LU
M N
DESIGN CRITERIA
CONCRETE: 4,000 PSI
REINFORCING: ASTM A615, GRADE 60
ALLOWABLE SOIL LATERAL PASSIVE PRESSURE: 250 PSF/FT
MAXIMUM SOIL LATERAL PRESSURE LIMIT: 1,500 PSF
NOTES:
1. SEE BATTER'S EYE STRUCTURE DRAWINGS ON SHEET C804/C805 FOR POST SPACING
AND ABOVE-GRADE STRUCTURE DETAILS.
2. FOUNDATIONS SIZED FOR A 40' HIGH BATTER'S EYE WITH A 36'-4" SOLID
SURFACE HEIGHT.
DETAIL
TYPICAL BATTER'S EYE FOUNDATION
NO SCALE
A
S1
EMBEDDED W16x67 COLUMN
SPACING PER C801
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C802
STRUCTURAL
FULL DEPTH TRENCH RESTORATION
NOT TO SCALE
TRENCH LIMITS
PAVE LAWN
LAWN RESTORATION
AS REQUIRED
SUITABLE BACKFILL COMPACTED IN 8"
LIFTS TO 95% MAXIMUM DRY DENSITY
12"
MIN
12" MIN
12"
MIN
PIPE
O.D.
6" MIN
DEPTH
VARIES
DEPTH
VARIES
PennDOT 2A COARSE AGGREGATE
COMPACTED IN 8" LIFTS TO 95%
MAXIMUM DRY DENSITY
BITUMINOUS PAVEMENT, SEE
PLAN FOR TYPE; SEE DETAIL
UNDISTURBED
EARTH
AASHTO #57
COARSE
AGGREGATE
UTILITY LINE; REFERENCE
PLAN FOR TYPE AND SIZE
NOTES:
1. PLACEMENT OF BACKFILL IN LIFTS UP TO 8" THICK IS ALLOWED WHEN VIBRATORY COMPACTION
EQUIPMENT IS BEING UTILIZED. USE MECHANICAL TAMPERS OR OTHER ACCEPTABLE
COMPACTION EQUIPMENT WITH CONSISTENT APPLICATION FORCE SO NO DAMAGE TO THE PIPE
OCCURS. BACKFILL WILL BE TESTED FOR 100% COMPACTION WHEN PLACED IN PAVED AREAS.
2. COMPACT THE TOP 3' OF BACKFILL MATERIAL TO 100% STANDARD PROCTOR DENSITY.
3. FOLLOW OSHA SAFETY REQUIREMENTS FOR SLOPE LAYBACKS OR PROVIDE SHORING AS REQUIRED.
NOTES:
1. PROVIDE MANHOLE STEPS FOR INLETS OVER 4' DEEP IN ACCORDANCE WITH PENNDOT PUBLICATION 72, RC-39M.
2. REFERENCE PENNDOT PUBLICATION 72, RC-45M, FOR ADDITIONAL DETAILS ON THE INLET FRAME AND GRATE
AND PRECAST CONCRETE GRADE ADJUSTMENT RINGS.
3. REFERENCE PENNDOT PUBLICATION 72, RC-46M, FOR ADDITIONAL DETAILS ON THE STANDARD INLET BOX.
4. REFERENCE PENNDOT PUBLICATION 72, RC-46M, FOR ADDITIONAL DETAILS ON THE TYPE 4 INLET BOX.
4"
6" (TYP.)
36"
6" (TYP.)
4"
2"
STRUCTURAL STEEL GRATE BICYCLE SAFE
PIPE OPENING
INSIDE FACE = 25"Ø MAX.
OUTSIDE FACE = 26"Ø MAX.
STANDARD INLET BOX
PIPE OPENING
PINSIDE FACE = 461
4"Ø MAX
OUTSIDE FACE = 471
4" MAX
6 TRANSVERSE RODS
22 BEARING BARS
PRECAST CONCRETE
GRADE ADJUSTMENT RING,
3" MIN - 10" MAX
A
TYPE M METAL TOP
INLET BOX
2 SPA @ 18"
(CENTERED)
4"
27"
2" 11
2"
4"
2" 41
2"
4"
16"
MIN LAP
LENGTH (TYP)
2"
2"
24"
2"
2"
36"
1 SPA @ 16"
(CENTERED)
8" STUDS OR #3 BENT
BAR ANCHORS (TYP)
2" 11
2"
4"6" 6"
2"11
2"TOP OF GRATE 21
2" 41
2" 11 2" 41
2"11 2"
24"6" 6"
2"
TOP OF GRATE
8" MIN
12" MAX
2"
2"
8"Ø x 21
2" STUDS
#3 @ 9" (TYP)
CLEAR (TYP)
PRECAST = 11
2"
CAST-IN-PLACE = 2"
2" MIN
3" MAX
2" MIN
3" MAX
#4 BARS (TYP)
DETAIL 1
SECTION A-A SECTION B-B
PLAN VIEW
B
A
B
BICYCLE SAFE STEEL GRATE
STANDARD INLET BOX - TYPE M CONCRETE TOP
NOT TO SCALE
DRAIN BASIN INLINE DRAIN
4" MIN ON 8" - 24"
6" MIN ON 30"
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM
D2321.
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR
OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS
OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN
ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE
INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN
ACCORDANCE WITH ASTM D2321.
TOP SOIL TOP SOIL
ADAPTER
ANGLES
VARIABLE
0° - 360°
VARIES (REFER TO
PIPE SCHEDULE)
(3) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN. ON 12" - 24", 10" MIN. ON 30"
& 12" MIN. ON 36"
BASED ON MANUFACTURING REQ.)
12" SUMP DEPTH
VARIES
(REFER TO PIPE
SCHEDULE)
VARIABLE INVERT HEIGHTS
AVAILABLE (REFER TO PIPE
SCHEDULE)
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR
OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS
OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN
ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE
INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN
ACCORDANCE WITH ASTM D2321.
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
VARIOUS TYPES OF INLET & OUTLET ADAPTERS
AVAILABLE: 4" - 36" FOR CORRUGATED HDPE (ADS
N-12/HANCOR DUAL WALL, ADS/HANCOR SINGLE WALL),
N-12 HP, PVC SEWER (EX: SDR 35), PVC DWV (EX: SCH 40),
PVC C900/C905, CORRUGATED & RIBBED PVC
8" OR 12" DOME GRATE -TYPE B, SEE DETAIL
FRAME & GRATE TO MATCH BASIN O.D.
(SEE PLAN FOR LOCATION OF 12" DOME GRATE)
NOTE:
1. NYLOPLAST DRAIN BASINS SHALL BE INSTALLED PER MANUFACTURER RECOMMENDATION.
NYLOPLAST DRAIN BASIN WITH
PEDESTRIAN GRATE INSTALLATION DETAIL
NOT TO SCALE
NYLOPLAST DRAIN BASIN AND INLINE DRAIN
NONTRAFFIC INSTALLATION DETAIL
NOT TO SCALE
NOTES:
QUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05
PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT
LOCKING DEVICE AVAILABLE UPON REQUEST
A A
SECTION A-A
8"/12" DOME GRATE - TYPE B
NOT TO SCALE
4" - (8" DOME)
5" - (12" DOME)
Ø 8.96" (8" DOME)
Ø 13.38" (12" DOME)
(SEE PLAN FOR LOCATION OF 12" DOME GRATE)
8" OR 12" DOME GRATE
(SEE PLAN FOR LOCATION OF 12" DOME GRATE)
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C803
F F
G
G
B
A
TOP TRIM LOW RIBBED PROFILE (3
4" H RIBS SPACED 6" O.C.) EXPOSED FASTENER
METAL WALL PANEL ON FRONT USING MBCI PBU 36" W 26* GAUGE
GALVALUME COATED STEEL PANELS WITH SIGNATURE 300 TWO-COAT
FLUOROPOLYMER FINISH. PANELS FIELD ASSEMBLED WITH SIDE LAPS
AND THROUGH FASTENED TO HORIZONTAL GIRTS. RELATED METAL
TRIM AND ATTACHMENT HARDWARE INCLUDED.
DETAIL A
36" 6" 3/4"
RIBBED PANEL PROFILE
DETAIL B
SIDE TRIM
4" SQUARE X 11 GAUGE
STEEL HORIZONTAL GIRTS
BOLTED TO WELDED STEEL
SUPPORT BRACKETS
SIDE WINDSHIELD
W16 X 67
EXTERIOR COLUMNS
W16 X 77
INTERIOR COLUMNS
LIGHT-COLORED ACRYLIC/POLYESTER
BACKER FINISH ON BACKSIDE OF
SURFACE PANELS
FINISH GRADE
10'-0"
BOTTOM BEAM
ELEV O.C.
3'-8"
36'-4"
W12 X 26
TOP BEAM
W12 X 26
BOTTOM BEAM
6" TO BEAM SET DOWN
40'-0"
80'-0"
STANDARD "HARBOR BLUE" POWDER COATED FINISH ON FRAMING COMPONENTS
ENGINEERED TO MEET ASCE 7-16 WIND
RATING UP TO 105 MPH, EXPOSURE B
FINISH GRADE
18'-1"
BEAM LENGTH
19'-1 5/16"
INTERIOR COLUMN
SPACING
19'-1 1/4"
EXTERIOR COLUMN
SPACING
ELEVATION VIEW
(SURFACE PANELS REMOVED FOR CLARITY)
8" X 2-1/4" L, GRADE A325 HD GALV.
HEX HEAD BOLT; W/(1) GRADE A563
DH GALV. HEAVY HEX NUT AND (2) 5 8"
GALV. F436 FLAT WASHER, 1-5/16" OD
1/2" X 5-1/2" GRADE 5 ECOGUARD FINISHED
HEX CAP SCREW WITH (2) FLAT WASHERS, (1)
LOCK WASHER, AND (1) GRADE 5 HEX
(SECURE GIRT TUBE TO ATTACHMENT ANGLE)
L 4" X 4" X 38" X
6"L EXTERIOR COLUMNS
7-1/2"L INTERIOR COLUMNS
SECTION G-G
GIRT ATTACHMENT ANGLES TO COLUMNS.
BEVEL GROVE WELD AT TOP TO PREVENT
INTERFERENCE WITH GIRT.
4"
BEAMS TO ATTACHMENT PLATES (TYP.)1
4"
12"
SECTION F-F
FRONT PANELING
HIDDEN FOR CLARITY
SIDE 16 GA FORMED STEEL WINDSHIELD,
POWDER COATED "HARBOR BLUE"
PL 12" A36 (TYP.)
1' 3 11
16" TYP
BOTH SIDES OF ATTACHMENT
PLATES TO COLUMN TYP
4"
HSS 4" X 4" 11 GA GIRTS
A500 GRADE B - TYP
48" O.C.
TYP
20'- 10 116"
EXTERIOR GIRT TUBES
80'-0"
19'- 0 116"
INTERIOR GIRT TUBES
36'-4"
SURFACE HEIGHT
40'-0"
EMBEDMENT PER SHEET C802
40' H X 80' W SOLID SURFACE BATTER'S EYE
(ALTERNATE 1)
NOT TO SCALE
NOTES:
1. ENGINEERED TO MEET ASCE 7-16 WIND RATING UP TO 105 MPH, EXPOSURE B
2. ALL W SHAPE STRUCTURAL MEMBERS CONFORM TO ASTM A922
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C804
ALTERNATE 1
F F
G
G
B
A
TOP TRIM LOW RIBBED PROFILE (3
4" H RIBS SPACED 6" O.C.) EXPOSED FASTENER
METAL WALL PANEL ON FRONT USING MBCI PBU 36" W 26* GAUGE
GALVALUME COATED STEEL PANELS WITH SIGNATURE 300 TWO-COAT
FLUOROPOLYMER FINISH. PANELS FIELD ASSEMBLED WITH SIDE LAPS
AND THROUGH FASTENED TO HORIZONTAL GIRTS. RELATED METAL
TRIM AND ATTACHMENT HARDWARE INCLUDED.
DETAIL A
36" 6" 3/4"
RIBBED PANEL PROFILE
DETAIL B
SIDE TRIM
4" SQUARE X 11 GAUGE
STEEL HORIZONTAL GIRTS
BOLTED TO WELDED STEEL
SUPPORT BRACKETS
SIDE WINDSHIELD
W14 X 61
EXTERIOR COLUMNS
W14 X 68
INTERIOR COLUMNS
LIGHT-COLORED ACRYLIC/POLYESTER
BACKER FINISH ON BACKSIDE OF
SURFACE PANELS
FINISH GRADE
10'-0"
BOTTOM BEAM
ELEV O.C.
3'-8"
32'-4"
W12 X 26
TOP BEAM
W12 X 26
BOTTOM BEAM
6" TO BEAM SET DOWN
36'-0"
60'-0"
STANDARD "HARBOR BLUE" POWDER COATED FINISH ON FRAMING COMPONENTS
ENGINEERED TO MEET ASCE 7-16 WIND
RATING UP TO 105 MPH, EXPOSURE B
36' H X 60' W SOLID SURFACE BATTER'S EYE
(ALTERNATE 2)
NOT TO SCALE
FINISH GRADE
18'-1"
BEAM LENGTH
19'-1"
INTERIOR COLUMN
SPACING
19'-1"
EXTERIOR COLUMN
SPACING
ELEVATION VIEW
(SURFACE PANELS REMOVED FOR CLARITY)
8" X 2-1/4" L, GRADE A325 HD GALV.
HEX HEAD BOLT; W/(1) GRADE A563
DH GALV. HEAVY HEX NUT AND (2) 5 8"
GALV. F436 FLAT WASHER, 1-5/16" OD
1/2" X 5-1/2" GRADE 5 ECOGUARD FINISHED
HEX CAP SCREW WITH (2) FLAT WASHERS, (1)
LOCK WASHER, AND (1) GRADE 5 HEX
(SECURE GIRT TUBE TO ATTACHMENT ANGLE)
L 4" X 4" X 38" X
6"L EXTERIOR COLUMNS
7-1/2"L INTERIOR COLUMNS
SECTION G-G
GIRT ATTACHMENT ANGLES TO COLUMNS.
BEVEL GROVE WELD AT TOP TO PREVENT
INTERFERENCE WITH GIRT.
4"
BEAMS TO ATTACHMENT PLATES (TYP.)1
4"
12"
SECTION F-F
FRONT PANELING
HIDDEN FOR CLARITY
SIDE 16 GA FORMED STEEL WINDSHIELD,
POWDER COATED "HARBOR BLUE"
PL 12" A36 (TYP.)
1' 3 11
16" TYP
BOTH SIDES OF ATTACHMENT
PLATES TO COLUMN TYP
4"
HSS 4" X 4" 11 GA GIRTS
A500 GRADE B - TYP
48" O.C.
TYP
20'- 10 116"
EXTERIOR GIRT TUBES
60'-0"
19'- 0 116"
INTERIOR GIRT TUBES
32'-4"
SURFACE HEIGHT
36'-0"
NOTES:
1. ENGINEERED TO MEET ASCE 7-16 WIND RATING UP TO 105 MPH, EXPOSURE B
2. ALL W SHAPE STRUCTURAL MEMBERS CONFORM TO ASTM A922
EMBEDMENT PER SHEET C802
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
C805
ALTERNATE 2
BOX
ELECTRIC
METER
ELECTRIC
METER
ELECTRIC
METER NO ID
PPL 19369 N39294
PPL 19370 N39297
PPL 19361 N39296
PPL 19361 N39299
PPL 19355 N39307
PPL 19342 N39299
X X
X X
X
X
X X
X X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X
X
X
XXXXXXXX
X
X
X
X
X
X
X X
X
X
X
X
X
BLAINE ST.
NE
W
CO
M
ER
A
VE
15" ALLEY
H
AM
M
ON
D
PL
N/F
CITY OF WILLIAMSPORT
TP# 70-013-302
DB 239 PG 471
N /F
CO
M
M
ON
W
EA
LT
H
O F
PA
TP
-0
-1
N/F
DEASE, MARY M. ET AL
TP# 70-013-125
" A
LL
EY
N/F
WILLIAMS, RODNEY S. ET AL
TP# 70-013-129
N/F
LING LU
TP# 70-013-130
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-130
N/F
PAULHAMUS, LARRY ET AL
TP# 70-013-111 N/F
VICK, MICHAEL S.
TP# 70-013-110
N/F McCLURE, WAYNE J. ET AL
TP# 70-013-109
N/F
BOROSCO, JOSEPH A. ET AL
TP# 70-013-108
N/F
BOROSCO, JOSEPH A. ET AL
TP# 70-013-107 N/F
KENNEDY, TANYA Y. ET AL
TP# 70-013-107
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
OHOH
X
X
X
X
X
X
X
X
X
PPL 19376 N39266
PPL 19357
N39259
PPL 19345 N39255
INLET RIM 524.54'
(N) 12" RCP 520.15'
(E) 12" 520.09'
(S) 12" RCP 519.97'
INLET RIM 518.82'
(N) 6" SLCPP 516.97'
(S) 12" SLCPP 516.40'
INLET RIM 518.95'
(N) 6" SLCPP
(S) 6" SLCPP
INLET RIM 519.45'
(N) 8" SLCPP 517.58
(W) 6" SLCPP 517.65'
(S) 8" SLCPP 517.54'
IRRIGATION SYSTEM WITH
6" LIDS
UE
UE
UE
UE
UE
UE
UE
OH
OH
OH
OH
OH
OH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
OH
OH
OH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UNKNOWN
UTILITY
X
X
SCORE
BOARD
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
X
X
X
X
X X
X
UNDERGROUND
COMMUNICATION
LINE
50' ROW
EDGE OF PAVEMENT
EDGE OF PAVEMENT
6" PVC
FIELD DRAIN
BENCHMARK
REBAR WITH LIVIC CAP
ELEV: 525.77
STADIUM
LIGHTS
FOUL POLE
FOUL POLE
STADIUM
LIGHTS
STADIUM
LIGHTS
LAYDOWN AREA
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
XX
X
STADIUM
LIGHTS
PPL 19352 N39297
UE UE UE UE UE
X X
X X
X
X
X
X
X
X
X
X
XXXXXXXX
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
LO
D
LO
D LOD
LOD
LOD
LOD
LOD
LOD LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LODLOD
LOD
LODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
ROCK CONSTRUCTION ENTRANCE
IP
IP
COMPOST FILTER SOCK
CONCRETE WASHOUT
FILTER BAG INLET
PROTECTION
FILTER BAG INLET
PROTECTION
PAVEMENT
RESTORATION
8" UNDERDRAIN
CONNECT UNDERDRAIN
TO 12" NYLOPLAST
YARD DRAIN
TYPE M INLET
12" SLCPP
12" SLCPP
IP
FILTER BAG INLET
PROTECTION
TYPE M INLET
CUT AND CONNECT EXISTING
PIPES INTO NEW INLET
PROTECT
UNDERGROUND LINES
PROTECT
UNDERGROUND LINES
30 30 60 FT0
HORIZONTAL SCALE: 1 INCH = 30 FEET
N
2ND FLOOR
635 N LOYALSOCK AVENUE
MONTOURSVILLE, PA 17754
PHONE: 888.987-1993
w w w . l i v i c c i v i l . c o m
SHEET NO.
SHEET TITLE
RE
V
DA
TE
CO
M
M
EN
TS
BY
CH
KD
IS
SU
E / R
EV
IS
IO
N
S
PROJECT
CLIENT
PROJECT No:
DRAWN BY: CHECKED BY:
SCALE:
DATE:
AS SHOWN
PHONE:
COUNTY
PENNSYLVANIA
ALL CONTENTS OF THIS PLAN ARE PROPRIETARY
AND SHALL NOT BE REPRODUCED OR UTILIZED FOR
A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N
AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY
A P P R O V E D , S E A L E D P L A N S S H A L L B E
IMPLEMENTED FOR CONSTRUCTION PURPOSES.
© 2 0 2 5 L I V I C C I V I L , L L C
1234-05
BOWMAN FIELD
OUTFIELD FENCE
REPLACEMENT
1500 W 3RD STREET
WILLIAMSPORT, PA, 17701
(570) 326-4684
LYCOMING
ADK
CITY OF
WILLIAMSPORT
DIS
CITY OF
WILLIAMSPORT
8.
.2
IS
SU
ED
F
O R
BI
D
DI
S
AD
K
ES501
EROSION AND
SEDIMENT
CONTROL PLAN
50' MIN.
FT.
EXISTING ROADWAY
20'
MIN.
EX
IS
TI
N
G R
O
AD
W
AY
PROFILE
PLAN VIEW
NOTES:
REMOVE TOPSOIL PRIOR TO INSTALLATION OF ROCK CONSTRUCTION ENTRANCE. EXTEND ROCK OVER FULL
WIDTH OF ENTRANCE.
RUNOFF SHALL BE DIVERTED FROM ROADWAY TO A SUITABLE SEDIMENT REMOVAL BMP PRIOR TO
ENTERING ROCK CONSTRUCTION ENTRANCE.
MOUNTABLE BERM SHALL BE INSTALLED WHEREVER OPTIONAL CULVERT PIPE IS USED AND PROPER PIPE COVER AS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .