1-2025.8.14 Bowman Field Construction Plan.pdf

PDF 10 MB Posted

Attached to
Bowman Field
Solicitation number
US.198829
Issued by
Lycoming County, Pennsylvania

View the file

Other files

File Type Posted
3-Addendum 1 2025.08.22.pdf PDF
2-Project Manual 2025.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. APPLICANT/RESPONSIBLE PARTY:

CITY OF WILLIAMSPORT

1500 W 3RD STREET

WILLIAMSPORT, PA 17701

PHONE: 570.326.4684

2. LANDOWNER:

· CITY OF WILLIAMSPORT

1500 W 3RD STREET

WILLIAMSPORT, PA 17701

3. PROJECT LOCATION:

WILLIAMSPORT, PA 17701

CITY OF WILLIAMSPORT, LYCOMING COUNTY

LOCATED ALONG THE SOUTH SIDE OF BLAINE STREET, APPROXIMATELY 200 FEET EAST OF THE INTERSECTION OF BLAINE STREET AND

NEWCOMER AVENUE.

4. PROJECT NARRATIVE:

5. THE CITY OF WILLIAMSPORT IS PROPOSING TO CONSTRUCT A NEW OUTFIELD FENCE AND BATTER'S EYE STRUCTURE AT THE HISTORICAL

BOWMAN FIELD. THE PROJECT WILL INCLUDE STORMWATER MANAGEMENT AND OTHER SITE FEATURES.

6. SOURCE OF TITLE:

DB: 239, PG: 471

PARCEL No. 70-013-302

7. NO EXISTING WETLANDS HAVE BEEN IDENTIFIED BY THE NATIONAL WETLANDS INVENTORY WEBSITE OR BY FIELD OBSERVATION.

8. ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY'S FLOOD INSURANCE RATE MAP (42081C0431G), THE PROJECT SITE IS

LOCATED WITHIN THE AREA WITH REDUCED FLOOD RISK DUE TO LEVEE FOR THE 100-YEAR FLOODPLAIN.

9. THE PROJECT WILL BE SERVED BY PUBLIC SANITARY SEWER AND PUBLIC WATER.

10. LIMIT OF DISTURBANCE: 0.85 ACRES

GENERAL NOTES

1-800-242-1776

PE

NN

SY

LV

ANIA ONE CALL SYSTEM

, INC

STOP

- CA L L BE FORE YOU

D I G

PENNSYLVANIA ONE CALL

1.

LIVIC CIVIL HAS REQUESTED LINE AND UTILITY INFORMATION FROM THE

PA ONE CALL SYSTEM (POCS)

2.

POCS SERIAL NUMBER: 20242530680

DATE: SEPTEMBER 9, 2024

3. THE FOLLOWING FACILITY OWNERS HAVE INDICATED THROUGH POCS

THAT THEY HAVE FACILITIES IN THE PROJECT AREA:

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

WILLIAMSPORT SANITARY AUTHORITY

253 W FOURTH STREET

WILLIAMSPORT, PA 17701

NOAH CAPUTO

NCAPUTO@WMWA-WSA.ORG

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

COMCAST

336 PENN STREET

WILLIAMSPORT, PA 17701

TIM CRISWELL

TIMOTHY_CRISWELL@CABLE.COMCAST.COM

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

WILLIAMSPORT MUNICIPAL WATER

AUTHORITY

253 W FOURTH STREET

WILLIAMSPORT, PA 17701

IAN MOWATT

IMOWATT@WMWA-WSA.ORG

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

PPL ELECTRIC UTILITIES CORPORATION

437 BLUE CHURCH ROAD

PAXINOS, PA 17860

DOUG HAUPT

DLHAUPT@PPLWEB.COM

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

CITY OF WILLIAMSPORT

1500 W THIRD STREET

WILLIAMSPORT, PA 17701

JENNIFER DUDEK

JDUDEK@CITYOFWILLIAMSPORT.ORG

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

VERIZON PENNSYLVANIA LLC

40 S MERCER STREET

NEW CASTLE, PA 16101

TRICIA JACOBS

TRICIA.L.JACOBS@VERIZON.COM

UTILITY:

ADDRESS:

CONTACT:

EMAIL:

UGI UTILITIES INC

1 UGI DRIVE

WILKES-BARRE, PA 18711

AMANDA NIXON

ANIXON@UGI.COM

4.

BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA CALL 1-800-242-1776. PA ACT 287 OF 1974, AS AMENDED, REQUIRES THREE

(3) WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST.

CONSTRUCTION PLANS

BOWMAN FIELD OUTFIELD FENCE REPLACEMENT

CITY OF WILLIAMSPORT, LYCOMING COUNTY, PENNSYLVANIA

WILLIAMSPORT USGS QUAD

SCALE: AS SHOWN

PROJECT LOCATION MAP

FOR

N

2,000 2,000 4,000 FT0

HORIZONTAL SCALE: 1 INCH = 2,000 FEET

DRAWING INDEX

SHEET NUMBER SHEET TITLE

C001 COVER SHEET

C002 GENERAL INFORMATION

C101 EXISTING CONDITIONS & DEMOLITION PLAN

C201 SITE LAYOUT PLAN

C301 GRADING & STORMWATER PLAN

C302 GRADING & STORMWATER PLAN

C303 GRADING & STORMWATER PLAN

C304 GRADING & STORMWATER PLAN

C801 DETAILS

C802 STRUCTURAL DETAILS

C803 DETAILS

C804 DETAILS ALTERNATE 1

C805 DETAILS ALTERNATE 2

ES501 EROSION AND SEDIMENT CONTROL PLAN

ES502 E&S DETAILS

ES503 E&S NOTES

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C001

COVER SHEET

AUGUST 14, 2025

GENERAL CONSTRUCTION NOTES

1. EXISTING UTILITIES SHOWN ON THIS PLAN ARE BASED ON EXISTING MAPPING RECORDS AND/OR EVIDENCE OF ABOVE GROUND FACILITIES. SUE

HAS BEEN COMPLETED BY TRINITY SUBSURFACE, LLC. PAINT AND FLAGGING BASED ON THE SUE HAS BEEN LOCATED BY LIVIC CIVIL. THE EXACT LOCATION (HORIZONTAL & VERTICAL) OR ACCURACY THERE OF IS NOT GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING DEPTHS AND LOCATIONS OF ANY AND ALL UTILITIES WHICH FALL WITHIN OR ADJACENT TO THE LIMITS OF WORK. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING UTILITIES AND MAINTAIN UNINTERRUPTED SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATELY REARING ANY DAMAGED UTILITY THAT OCCURS DURING CONSTRUCTION, AT THEIR EXPENSE. THE CONTRACTOR IS REQUIRED TO COMPLETE THEIR UTILITY NOTIFICATIONS PER STATE LAW AND FOLLOW ANY AND ALL REGULATIONS.

2. THE CONTRACTOR IS TO NOTIFY OWNER/ENGINEER, IN WRITING, OF ANY UTILITY CONDITIONS AT THE SITE DIFFERING FROM THOSE INDICATED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH UTILITY OWNERS FOR THE ADJUSTMENT OR RELOCATION OF UTILITY SURFACE FEATURES, I.E. VALVE BOXES, UTILITY POLES, MANHOLES, ETC. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE RELOCATION OF CONFLICTING UTILITIES WHICH ARE A RESULT OF THESE IMPROVEMENTS.

3. THE OWNER SHALL PREPARE AND EXECUTE NECESSARY UTILITY EASEMENTS FOR PROPOSED RELOCATED UTILITIES IN ACCORDANCE WITH THE

REQUIREMENTS BY THE UTILITY OWNER.

4. EXISTING INFORMATION AND FEATURES SHOWN ON THIS SITE PLAN WERE TAKEN FROM A SURVEY PREPARED BY LIVIC CIVIL, DATED SEPTEMBER 9

& 18, 2024. THE FOLLOWING BENCH MARK HAS BEEN ESTABLISHED:

· BM1 - REBAR WITH LIVIC CAP

·· N: 392822.81 / E: 2162361.13 / ELEV: 525.77

5. THERE ARE NO NAVIGABLE STREAMS WITHIN THE PROJECT LIMITS.

6. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL BENCH MARKS AND CONTROL POINTS DURING CONSTRUCTION. CONTRACTOR SHOULD SET

ADDITIONAL CONTROL AS DEEMED APPROPRIATE.

7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE, REVIEW AND UNDERSTAND THE PLAN AND SPECIFICATIONS AND VERIFY ALL FIELD CONDITIONS, DIMENSIONS, DRAWINGS AND SPECIFICATIONS. ANY INCONSISTENCIES OR AMBIGUITIES IN THE DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE PROJECT'S OWNER IN WRITING. WORK COMPLETED BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES OR AMBIGUITIES, WITHOUT RECEIVING A RESPONSE FROM THE PROJECT'S OWNER, SHALL BE DONE AT THE

CONTRACTOR'S RISK.

8. THE CONTRACTOR SHALL COMPLETE THEIR UTILITY NOTIFICATIONS PER STATE LAW. CONTRACTOR IS TO NOTIFY OWNER/ENGINEER, IN WRITING, OF ANY UTILITY CONDITIONS AT THE SITE DIFFERING FROM THOSE INDICATED IN THE CONTRACT DOCUMENTS.

9. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL OTHER APPLICABLE TRADES (SITE, STRUCTURAL, PLUMBING, ELECTRICAL, ETC.) AS REQUIRED.

10. THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS, CODES AND REGULATIONS.

11. THE CONTRACTOR AND ANY SUBCONTRACTORS SHALL BE NOTIFIED THAT THEY ARE REQUIRED TO COMPLY WITH THE OCCUPATIONAL SAFETY

AND HEALTH ACT (OSHA), WHICH APPLY TO ALL PHASES OF CONSTRUCTION.

12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL, TRENCH SAFETY, COVERING, PLATING, SHEETING, SHORING AND SHORING

DESIGN AS NEEDED.

13. THIS PLAN IS NOT INTENDED TO REPRESENT ANY SUBSURFACE CONDITIONS, INCLUDING THE LOCATION OF BEDROCK OR OTHER GEOLOGICAL

CONDITIONS.

14. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE SAFE FLOW OF TRAFFIC DURING CONSTRUCTION. MAINTENANCE AND PROTECTION OF TRAFFIC DURING CONSTRUCTION SHALL BE IN ACCORDANCE WITH PennDOT PUBLICATION 213, "TEMPORARY TRAFFIC CONTROL GUIDELINES", AS

AMENDED.

15. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL REQUIRED NOTIFICATIONS AS SPECIFIED ON SUPPLIED PERMIT OF PERMIT PLANS. THIS INCLUDES MUNICIPALITIES, CONSERVATION DISTRICTS, PADEP, PennDOT AND OTHER REGULATORY AGENCIES.

16. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH UTILITY OWNERS FOR THE ADJUSTMENT OR RELOCATION OF UTILITY SURFACE FEATURES, I.E. VALVE BOXES, UTILITY POLES, MANHOLES, ETC. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE RELOCATION OF

CONFLICTING UTILITIES WHICH ARE A RESULT OF THESE IMPROVEMENTS.

17. CONSTRUCTION IS TO BE BASED ON ACTUAL FIELD STAKING OF IMPROVEMENTS BY A REGISTERED PROFESSIONAL ENGINEER. ANY DEVIATIONS

FROM THE STAKEOUT OR PLAN SHALL NOT BE PERMITTED WITHOUT APPROVAL.

18. THE CONTRACTOR SHALL ENSURE THAT POSITIVE DRAINAGE ACROSS ALL GRADED AREAS IS PROVIDED AND NO LOW SPOTS OR PONDING OCCUR

WITHIN THE LIMITS OF WORK UNLESS NATURALLY OCCURRING.

19. ALL EXISTING SIGNS, WHICH ARE DISTURBED DURING CONSTRUCTION, SHALL BE REINSTALLED IMMEDIATELY IN ACCORDANCE WITH APPLICABLE

FEDERAL, STATE, AND LOCAL REGULATIONS.

20. THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING MEASURES TO PREVENT DAMAGE TO ALL EXISTING FEATURES (TO REMAIN) WITHIN THE

PROJECT LIMITS AND ALONG ADJACENT PROPERTIES.

21. ALL AREAS WHICH ARE DISTURBED BY CONSTRUCTION, THAT ARE NOT TO BE PAVED OR HAVE SPECIFIC RESTORATION DETAILS, SHALL BE

RESTORED WITH A MINIMUM SIX (6") INCHES OF TOPSOIL AND SEEDED AND MULCHED.

22. PER PennDOT PUBLICATION 408, SECTION 409.3-CONSTRUCTION, NO BITUMINOUS PAVEMENT WILL BE PLACED BETWEEN NOVEMBER 1 AND MARCH 31, UNLESS AN EXTENSION OF THE PAVING SEASON IS GRANTED IN WRITING BY THE DISTRICT EXECUTIVE. ALL ASPHALT TO ASPHALT AND ASPHALT TO CONCRETE JOINTS SHALL BE SEALED IN ACCORDANCE WITH PUB 408, SECTION 409.3(k)3.

23. THE CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT THE WORKMEN AND THE PUBLIC SHALL BE PROTECTED FROM INJURY WHILE PROTECTING THE ADJOINING PROPERTY FROM DAMAGE. THE CONTRACTOR SHALL KEEP THE WORK AREA FREE OF ACCUMULATION OF WASTE MATERIAL. THE CONTRACTOR SHALL REMOVE ALL WASTE MATERIAL FROM THE PROJECT SITE, AS WELL AS ALL TOOLS, EQUIPMENT AND SURPLUS

MATERIAL.

24. ALL STORMWATER MANAGEMENT FACILITIES AND BMPs SHALL BE PERMANENT FIXTURES AND CANNOT BE MODIFIED WITHOUT PRIOR APPROVAL OF THE MUNICIPALITY AND COUNTY CONSERVATION DISTRICT. MODIFICATION, REMOVAL, FILING, LANDSCAPING, OR ALTERING ANY

STORMWATER FACILITY, BMP OR EASEMENT, SHALL BE OTHERWISE PROHIBITED.

25. THE DESIGNATION OF EXCESS WASTE DISPOSAL AND CONSTRUCTION STAGING AREAS, WHICH MAY BE REQUIRED BUT ARE NOT SHOWN ON THE PLANS, ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL CONSTRUCTION WASTE AND DEBRIS, INCLUDING EXCESS EXCAVATED MATERIAL, ASPHALT, CONCRETE, SCRAP WOOD, ETC., SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS MATERIAL SHALL BE DISPOSED OF OFF-SITE

IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.

26. ALL TRENCHING SHALL OCCUR AS DESIGNATED BY THE PLANS. THE CONTRACTOR SHALL USE EQUIPMENT APPROPRIATE TO MAINTAIN A MAXIMUM PAVEMENT OPENING. IF A REVISED TRENCHING METHOD OR ALIGNMENT IS PROPOSED, THE CONTRACTOR SHALL NOTIFY THE PROJECT

ENGINEER AND OWNER IMMEDIATELY.

27. ALL EXCAVATIONS SHALL BE KEPT DRY TO PROTECT THEIR INTEGRITY. A SEDIMENT FILTER BAG OR EQUAL IMPLEMENTATION OF FILTERING IS

REQUIRED BEFORE DISCHARGING.

28. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONTINUOUSLY MAINTAINED, RELOCATED WHEN NECESSARY AND SHALL BE INSPECTED AFTER EVERY RAINFALL EVENT. THE CONTRACTOR SHALL CHECK SEEDED AREAS REGULARLY. THESE AREAS SHALL BE WATERED, FERTILIZED, RESEED AND MULCHED AS NECESSARY, TO OBTAIN STABILIZED COVER.

29. THE CONTRACTOR SHALL COMPLY WITH THE APPROVED EROSION AND SEDIMENT CONTROL PLAN. RE-GRADING, STRIPPING OF VEGETATION AND ANY OTHER WORK, SHALL BE DONE IN A MANNER TO MINIMIZE EROSION. EROSION AND SEDIMENT CONTROL BMPs REQUIRED BY THE CONSERVATION DISTRICT SHALL BE INSTALLED BY THE CONTRACTOR. SHOULD SEDIMENTATION OCCUR, IT IS THE RESPONSIBILITY OF THE ENTITY CAUSING THE SEDIMENTATION TO REMOVE IT FROM ANY AFFECTED AREAS. ANY DISTURBED AREAS SHALL BE STABILIZED IMMEDIATELY.

TEMPORARY VEGETATION AND/OR MULCHING MAY BE UTILIZED TO PROTECT EXPOSED CRITICAL AREAS DURING CONSTRUCTION. DUST CONTROL

MEASURES SHOULD BE EXERCISED DURING THE ENTIRETY OF CONSTRUCTION.

30. THE INFORMATION SHOWN ON THIS PLAN MAY HAVE ALSO BEEN RELEASED IN A DIGITAL DRAWING FORMAT. ONCE LIVIC CIVIL HAS RELEASED SUCH INFORMATION, WE TAKE NO RESPONSIBILITY OF ANY CHANGES THAT MAY OCCUR. THE ORIGINAL SEALED PLANS SHOULD BE REFERENCED TO ANY REPRODUCED MATERIAL THAT MAY BE VIEWED. ALSO ANY DIGITAL FILES OR DATA CONTAINED WITHIN, BEING USED WILL COME AT THE

RISK OF THE USER.

ABBREVIATIONS

BOTTOM OF CURB

HIGH POINT

TOP OF CURB

BOTTOM OF WALL

TOP OF WALL

TO BE REMOVED

BC

BW

HP

TBR

TC

TW

TYPTYPICAL

STORM SEWER/INLET

SANITARY SEWER

CONTOUR LINE-MAJOR

PROPERTY LINE

BUILDING SETBACK

CENTER LINE OF ROAD

PLAN TEXT

EXISTING

BUILDING LINE

EDGE OF PAVEMENT

CONCRETE CURB

CONCRETE SIDEWALK

SIGN

FENCE LINE

BENCHMARK

UNDERGROUND ELECTRIC

SEWER FORCE MAIN

GAS MAIN/VALVE

OVERHEAD UTILITIES & POLE

WATER MAIN/VALVE

PLAN TEXT PLAN TEXT

PROPOSED

RIGHT-OF-WAY LINE

EASEMENT LINE

GRAVEL

CONTOUR LINE-MINOR

X

EDGE OF WATER

G

S

FM

OH

UE

W

GUIDE RAIL

X

G

S

FM

OH

UE

W

LEGEND

100 100

DY

H DY

H

GV

FIRE HYDRANT

WV

0 0DATA/COMMUNICATION

WsB

NPDES PERMIT BOUNDARY NPDES

LIMIT OF DISTURBANCE LOD

SOIL BOUNDARY

SOIL DESIGNATOR

MANHOLE

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C002

GENERAL

INFORMATION

COMMUNICATIONS

JUNCTION

BOX

ELECTRIC

METER

ELECTRIC METER

ELECTRIC

METER

NO ID

PPL 19369 N39294

PPL 19370 N39297

PPL 19361 N39296

PPL 19361 N39299

PPL 19355 N39307

PPL 19342 N39299

BACK STOP

(TBR BY OTHERS)

15" HEMLOCK

(TBR BY OTHERS)

12" HEMLOCKS

(TBR BY OTHERS)20" HEMLOCK

(TBR BY OTHERS)

24" HEMLOCK

(TBR BY OTHERS)

SCAFFOLDING

(TBR BY OTHERS)

SCAFFOLDING

(TBR BY OTHERS)

6x6

(TYP)TBR

4" DIAMETER POST

WITH METAL BAND

TO FENCE (TYP) TBR

X X

X

X

X X

X

X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

XXXXXX

X

X

X

X

X X

X

X

X

X

X

X

XXXXXXX

X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

XXXXXX

X

X

BLAINE ST.

NE

W

CO

M

ER

A

VE

15" ALLEY

H

AM

M

ON

D

PL

N/F

CITY OF WILLIAMSPORT

TP# 70-013-302

DB 239 PG 471

N /F

CO

M

M

ON

W

EA

LT

H

O F

PA

TP

-0

-1

N/F

DEASE, MARY M. ET AL

TP# 70-013-125

" A

LL

EY

N/F

WILLIAMS, RODNEY S. ET AL

TP# 70-013-129

N/F

LING LU

TP# 70-013-130 N/F

PAULHAMUS, LARRY

ET AL

TP# 70-013-130

N/F

PAULHAMUS, LARRY

ET AL

TP# 70-013-111 N/F

VICK, MICHAEL S.

TP# 70-013-110 N/F

McCLURE, WAYNE

J. ET AL

TP# 70-013-109

N/F

BOROSCO, JOSEPH

A. ET AL

TP# 70-013-108

N/F

BOROSCO, JOSEPH A.

ET AL

TP# 70-013-107

N/F

KENNEDY, TANYA Y.

ET AL

TP# 70-013-107

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

X

X

XX

X

X X

X

X

X

X

X

PPL 19376 N39266

PPL 19357

N39259

PPL 19345 N39255

INLET RIM 524.54'

(N) 12" RCP 520.15'

(E) 12" 520.09'

(S) 12" RCP 519.97'

INLET RIM 519.12'

(N) 12" RCP 515.78'

(S) 12" RCP 516.07'

INLET RIM 518.82'

(N) 6" SLCPP 516.97'

(S) 12" SLCPP 516.40'

INLET RIM 518.95'

(N) 6" SLCPP

(S) 6" SLCPP

INLET RIM 519.45'

(N) 8" SLCPP 517.58

(W) 6" SLCPP 517.65'

(S) 8" SLCPP 517.54'

IRRIGATION SYSTEM

WITH 6" LIDS

UE

UE

UE

UE

UE

UE

UE

UE

UE

OH

OH

OH

OH

UE

UE

UE

UE

UE

UE

UEUE

UE

UE

UE

OH

OH

UE

UE

UE

UE

UE

UE

UNKNOWN

UTILITY

X

X

SCORE

BOARD

S

S

S

S

S

S

S

S

S

S

S

S

S

START FENCE REMOVAL AT START OF 12' FENCE.

BULLPEN FENCE AND 8' FENCE TO REMAIN.

END FENCE REMOVAL AT END OF 12' FENCE.

BULLPEN FENCE AND 8' FENCE TO REMAIN.

X

X

X

X

X

20' WIDE WARNING TRACK

UNDERGROUND

COMMUNICATION

LINE

50' ROW

EDGE OF PAVEMENT

EDGE OF PAVEMENT

6" PVC

FIELD DRAIN

BENCHMARK

REBAR WITH LIVIC CAP

ELEV: 525.77

BULLPEN

BULLPEN

FENCING

(TBR BY OTHERS)

GRASS OUTFIELD

STADIUM

LIGHTS

FOUL POLE

TO BE REPLACED

FOUL POLE

TO BE REPLACED

STADIUM

LIGHTS

STADIUM

LIGHTS

LAYDOWN AREA

X X

X

X

X

X

X

X

X

X

X X

X

X X

X X

X X

X X

X X

X X

X X

X

XX

X

INSTALL TEMPORARY CHAINLINK

CONSTRUCTION FENCE

INSTALL TEMPORARY CHAINLINK

CONSTRUCTION FENCE

STADIUM

LIGHTS

PPL 19352 N39297

UE UE UE UE

SAWCUT CLEAN LINES IN

PAVEMENT TO INSTALL

STORM PIPE

AREA OF REMOVAL

LIMIT OF DEMOLITION

LEGEND

TO BE REMOVEDTBR

40 40 80 FT0

HORIZONTAL SCALE: 1 INCH = 40 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C101

EXISTING

CONDITIONS &

DEMOLITION PLAN

AUGUST 14, 2025

NOTES:

CONTRACTOR TO REMOVE ALL COMPONENTS OF OUTFIELD FENCE FROM END TO

END - WALL, POSTS, FENCE BOARDS, REAR SUPPORTS AND FOUNDATIONS.

BULL PEN FENCE AND FOUL POLES TO REMAIN IN PLACE AS IS.

FOUL POLES TO REMAIN AS IS.

CONTRACTOR SHALL HAVE ACCESS TO WARNING TRACK AREA BUT NOT GRASS

OUTFIELD.

CITY OF WILLIAMSPORT WILL REMOVE ALL MATERIALS, TEMPORARY FENCING,

ETC. BEYOND THE OUTFIELD FENCE

CITY OF WILLIAMSPORT TO REMOVE TREES WHERE SHOWN AS WELL AS THE

BACKSTOP.

BOX

ELECTRIC

METER

ELECTRIC

METER

ELECTRIC

METER NO ID

PPL 19369 N39294

PPL 19370 N39297

PPL 19361 N39296

PPL 19361 N39299

PPL 19355 N39307

PPL 19342 N39299

X X

X X

X

X

X X

X X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X X

X X

X

X

X

X

X

X

X

XXXXXXXX

X

X

X

X

X

X

X X

X

X

X

X

X

BLAINE ST.

NE

W

CO

M

ER

A

VE

15" ALLEY

H

AM

M

ON

D

PL

N/F

CITY OF WILLIAMSPORT

TP# 70-013-302

DB 239 PG 471

N /F

CO

M

M

ON

W

EA

LT

H

O F

PA

TP

-0

-1

N/F

DEASE, MARY M. ET AL

TP# 70-013-125

" A

LL

EY

N/F

WILLIAMS, RODNEY S. ET AL

TP# 70-013-129

N/F

LING LU

TP# 70-013-130

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-130

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-111 N/F

VICK, MICHAEL S.

TP# 70-013-110

N/F McCLURE, WAYNE J. ET AL

TP# 70-013-109

N/F

BOROSCO, JOSEPH A. ET AL

TP# 70-013-108

N/F

BOROSCO, JOSEPH A. ET AL

TP# 70-013-107 N/F

KENNEDY, TANYA Y. ET AL

TP# 70-013-107

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OHOH

X

X

X

X

X

X

X

X

X

PPL 19376 N39266

PPL 19357

N39259

PPL 19345 N39255

INLET RIM 524.54'

(N) 12" RCP 520.15'

(E) 12" 520.09'

(S) 12" RCP 519.97'

INLET RIM 518.82'

(N) 6" SLCPP 516.97'

(S) 12" SLCPP 516.40'

INLET RIM 518.95'

(N) 6" SLCPP

(S) 6" SLCPP

INLET RIM 519.45'

(N) 8" SLCPP 517.58

(W) 6" SLCPP 517.65'

(S) 8" SLCPP 517.54'

IRRIGATION SYSTEM WITH

6" LIDS

UE

UE

UE

UE

UE

UE

UE

OH

OH

OH

OH

OH

OH

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

OH

OH

OH

UE

UE

UE

UE

UE

UE

UE

UE

UE

UNKNOWN

UTILITY

X

X

SCORE

BOARD

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

X

X

X

X

X X

X

UNDERGROUND

COMMUNICATION

LINE

50' ROW

EDGE OF PAVEMENT

EDGE OF PAVEMENT

6" PVC

FIELD DRAIN

BENCHMARK

REBAR WITH LIVIC CAP

ELEV: 525.77

STADIUM

LIGHTS

STADIUM

LIGHTS

STADIUM

LIGHTS

LAYDOWN AREA

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

XX

X

INSTALL TEMPORARY CHAINLINK

CONSTRUCTION FENCE

INSTALL TEMPORARY CHAINLINK

CONSTRUCTION FENCE

STADIUM

LIGHTS

PPL 19352 N39297

UE UE UE UE UE

X X

X X

X

X

X

X

X

X

X

X

XXXXXXXX

TIE PROPOSED 12' FENCE

INTO EXISTING 8' FENCE

AT TRANSITION

TIE EXISTING BULLPEN FENCE

INTO PROPOSED FENCE

TIE EXISTING BULLPEN FENCE

INTO PROPOSED FENCE

TIE PROPOSED UNDERDRAIN INTO

EXISTING FIELD UNDERDRAIN.

FIELD VERIFY LOCATION AND

DEPTH OF EXISTING UNDERDRAIN

LOD LOD LOD LOD LOD LOD

LOD

LOD

LOD

LOD

LOD

LO

D

LO

D

LO

D

LO

D

LOD

LO

D

LO

D

LO

D LOD

LOD

LOD

LOD

LOD

LOD LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LODLOD

LODLODLODLOD

LOD

LOD

LOD

LOD

LOD

LOD

CONCRETE CURB

TOP OF CURB: 521.90

TIE PROPOSED 12' FENCE INTO

EXISTING 8' FENCE AT TRANSITION

PAVEMENT

RESTORATION

8" UNDERDRAIN

CONNECT UNDERDRAIN

TO 12" NYLOPLAST

YARD DRAIN

TYPE M INLET

12" SLCPP

12" SLCPP

TYPE M INLET

CUT AND CONNECT EXISTING

PIPES INTO NEW INLET

PROTECT

UNDERGROUND LINES

PROTECT

UNDERGROUND LINES

BATTER'S EYE CENTERED ON LINE OF SIGHT

FROM HOME PLATE TO PITCHER'S MOUND

(INSTALL PER DETAIL SHEET C801/C802)

(ALTERNATE 1 - 80' WIDE X 40' TALL)

(ALTERNATE 2 - 60' WIDE X 36' TALL)

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

30 30 60 FT0

HORIZONTAL SCALE: 1 INCH = 30 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C201

SITE LAYOUT PLAN

AUGUST 14, 2025

BA

TT

ER

'S

SI

GHT

LIN

E

NOTES:

RELOCATE IRRIGATION SYSTEM IN FRONT OF NEW FENCE -

CONTRACTOR TO SALVAGE EXISTING SYSTEM, RESET IT IN

FRONT OF EXISTING FENCE AND MAKE ANY REQUIRED

RECONNECTIONS.

BOX

ELECTRIC

METER

ELECTRIC

METER

ELECTRIC

METER NO ID

PPL 19369 N39294

PPL 19370 N39297

PPL 19361 N39296

X X

X X

X

X

X X

X X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X X

X X

X

X

X

X

X

X

X

XXXXXXXX

X

X

X

X

X

X

X X

X

X

X

X

X

N/F

CITY OF WILLIAMSPORT

TP# 70-013-302

DB 239 PG 471

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

X

X

X

X

X

X

X

X

X

PPL 19376 N39266

PPL 19357

N39259

INLET RIM 524.54'

(N) 12" RCP 520.15'

(E) 12" 520.09'

(S) 12" RCP 519.97'

INLET RIM 519.45'

(N) 8" SLCPP 517.58

(W) 6" SLCPP 517.65'

(S) 8" SLCPP 517.54'

IRRIGATION SYSTEM WITH

6" LIDS

UE

UE

UE

UE

OH

OH

OH

OH

OH

OH

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

OH

OH

UE

UE

UE

UE

UE

UE

UE

UNKNOWN

UTILITY

X

X

SCORE

BOARD

S

S

S

S

S

S

S

S

S

S

S

S

X

X

X

X

X X

X

UNDERGROUND

COMMUNICATION

LINE

6" PVC

FIELD DRAIN

BENCHMARK

REBAR WITH LIVIC CAP

ELEV: 525.77

STADIUM

LIGHTS

STADIUM

LIGHTS

STADIUM

LIGHTS

LAYDOWN AREA

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

STADIUM

LIGHTS

PPL 19352 N39297

UE UE UE UE UE

X X

X X

X

X

X

X

X

X

X

X

XXXXXXXX

LOD LOD LOD LOD LOD LOD

LOD

LOD

LOD

LOD

LOD

LO

D

LO

D

LO

D

LO

D

LOD

LO

D

LO

D

LO

D LOD

LOD

LOD

LOD

LOD

LOD LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LODLOD

LODLODLODLOD

LOD

LOD

LOD

LOD

LOD

LOD

PAVEMENT

RESTORATION

8" UNDERDRAIN

CONNECT UNDERDRAIN

TO 12" NYLOPLAST

YARD DRAIN

TYPE M INLET

12" SLCPP

12" SLCPP

TYPE M INLET

CUT AND CONNECT EXISTING

PIPES INTO NEW INLET

PROTECT

UNDERGROUND LINES

PROTECT

UNDERGROUND LINES

BATTER'S EYE CENTERED ON LINE OF SIGHT

FROM HOME PLATE TO PITCHER'S MOUND

(INSTALL PER DETAIL SHEET C801/C802)

(ALTERNATE 1 - 80' WIDE X 40' TALL)

(ALTERNATE 2 - 60' WIDE X 36' TALL)

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

UNDERDRAIN TO I-3 PROFILE

1.

1.

0.

1.

1.

1.

1.

1.

2.

2.

2.

2.

2.

1.

1.

1.

1.

1.

0.

0.

0.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

0+00 1+00 2+00 3+00 4+00 5+00 6+00 6+70.90

I-2 T/G:521.60

INV IN:518.05 12" SLCPP NW

INV OUT:518.05 12" SLCPP SE

YD-1

T/G:521.11

INV IN:518.45 8" PVC N

INV IN:518.45 8" PVC S

INV OUT:518.28 12" SLCPP SE

I-1 T/G:522.04

INV IN:517.81 12" SLCPP NW

113' OF 12" SLCPP @ 0.20%

YD-3

T/G:521.16

INV IN:518.71 8" PVC NW

INV OUT:518.71 8" PVC S YD-2

T/G:521.13

INV IN:518.61 8" PVC N

INV OUT:518.61 8" PVC S

112' OF 12" SLCPP @ 0.21%

YD-4

T/G:521.18

INV IN:518.82 8" PVC NW

INV OUT:518.82 8" PVC SE

YD-5

T/G:521.25

INV IN:518.90 8" PVC NW

INV OUT:518.90 8" PVC SE

YD-6

T/G:521.31

INV IN:518.96 8" PVC W

INV OUT:518.96 8" PVC SE

YD-7

T/G:521.40

INV IN:519.05 8" PVC W

INV OUT:519.05 8" PVC E

YD-8

T/G:521.46

INV IN:519.11 8" PVC W

INV OUT:519.11 8" PVC E

YD-9

T/G:521.80

INV OUT:519.44 8" PVC E

8" UNDERDRAIN

SEE C803 FOR DETAILS

FIELD VERIFY DEPTH AND LOCATION

OF EXISTING UNDERGROUND

COMMUNICATION LINE

EXISTING SANITARY SEWER

FIELD VERIFY DEPTH

EXISTING UNDERGROUND ELECTRIC

AND COMMUNICATION LINE

FIELD VERIFY DEPTH

30 30 60 FT0

HORIZONTAL SCALE: 1 INCH = 30 FEET

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C301

GRADING &

STORMWATER

PLAN

AUGUST 14, 2025

30 30 60 FT0

HORIZONTAL SCALE: 1 INCH = 30 FEET

N

6 6 12 FT0

VERTICAL SCALE: 1 INCH = 6 FEET

X X

X X

X X

X X

X X

X X

XX

X

X

X

X

X

X

X

XXXXXXXXXXXXXXXXX

X

X

X

X

X

X

X

XX

X

X

X

X

X

X

X

N/F

LING LU

TP# 70-013-130

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

20' WIDE WARNING TRACK

6" PVC

FIELD DRAIN

521.34

521.25

521.25

521.38

521.34

521.33

BULLPEN

GRASS OUTFIELD

STADIUM LIGHTS

STADIUM LIGHTS

X X

X X

X X

X X

X

XX

X

X

X

X

X

X

UE UE UE UE UE UE UE UE UE UE UE UE UE UE

521.26

521.31

XXXXXXXXXXXXXXX

TIE PROPOSED 12' FENCE INTO

EXISTING 8' FENCE AT TRANSITION

TIE EXISTING BULLPEN FENCE

INTO PROPOSED FENCE

A-A

CONCRETE CURB

TOP OF CURB: 521.90

8" UNDERDRAIN

4" UNDERDRAIN

(ALTERNATE 3)

EXTENT OF GRADING

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

-1 .2

-0.8%

-1 .0

YD-9

521.13

521.13

521.05

521.22 521.08

ELECTRIC METER

ELECTRIC METER

PPL 19342 N39299

X

XXXXXXX

TP# 70-013-130

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-130

X

X X

X

UE

UE

UE

UEUE

UE UE UE UE

UE

UE UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

X

X

X

X

XSCORE

BOARD

X X

X X

X X

X X

UE UE UE

X

XXXXXXX

CONDUIT TO BE REMOVED FROM

EXISTING FENCE AND REATTACHED

TO PROPOSED CHAINLINK FENCE

-1 7.

5%

-6 .5

-5 .1

YD-8

521.13

521.51

10 10 20 FT0

HORIZONTAL SCALE: 1 INCH = 10 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C302

STORMWATER

PLAN

PPL 19352 N39297

PLATFORM

PITCH

CLOCK

FLAG POLE

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

XX

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-130

X

X

X

X

X

UE

UE

UE UE UE

UE

UE UE UE UE UE UE UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE UE UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

X

X

X

X

X

6" PVC

FIELD DRAIN

521.26

521.31

521.17

521.26

521.14

521.16

521.25

521.21

521.17

521.18

521.15

521.12

521.19

521.20

521.22

521.22

521.33

STADIUM LIGHTS

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

521.16

ELECTRIC METER

ELECTRIC METER

SCORE

BOARD

STADIUM LIGHTS

PPL 19342 N39299

UE

UE

UE

UE

UE

UE

UE

UE

UE

521.26

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

XXX

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

A-A

CONDUIT TO BE REMOVED FROM

EXISTING FENCE AND REATTACHED

TO PROPOSED CHAINLINK FENCE

8" UNDERDRAIN

CONCRETE CURB

TOP OF CURB: 521.90

BATTER'S EYE CENTERED ON LINE OF SIGHT

FROM HOME PLATE TO PITCHER'S MOUND

(INSTALL PER DETAIL SHEET C801/C802)

(ALTERNATE 1 - 80' WIDE X 40' TALL)

(ALTERNATE 2 - 60' WIDE X 36' TALL)

4" UNDERDRAIN

(ALTERNATE 3)

EXTENT OF GRADING

-17.5%

-2 2.

3% -2 5.

7%

-2 2.

5%

-1 8.

2%

-1 5.

9%

-1 5.

8%

-1 2.

4%

-13.9%

-10.1%

-6.5%

-5 .1

-1.2%

YD-2

YD-3

YD-4

YD-5

YD-6

YD-7

YD-8

521.13

521.13

521.13

521.13

521.13

521.13

521.13

521.13

521.22

521.51

521.08

522.14

522.51

522.67 522.33

522.61

521.74

521.63

10 10 20 FT0

HORIZONTAL SCALE: 1 INCH = 10 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C303

STORMWATER

JUNCTION BOX

ELECTRIC METER

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X

XXXXXXXXXXX

X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

INLET RIM 519.45'

(N) 8" SLCPP 517.58

(W) 6" SLCPP 517.65'

(S) 8" SLCPP 517.54'

IRRIGATION SYSTEM

WITH 6" LIDS

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UEUEUE

UEUE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UEUE

UE

UE

UE

UNKNOWN

UTILITY

UNDERGROUND

COMMUNICATION

LINE

6" PVC

FIELD DRAIN

521.25

521.21

521.27

521.28

521.35

521.32

521.35

521.19521.20 521.22

521.22

521.20

BULLPEN

STADIUM LIGHTS

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X

STADIUM LIGHTS

521.17

X

X X

X X

X X

X X

X X

X

XXXXXXXXXXX

X

TIE EXISTING BULLPEN FENCE

INTO PROPOSED FENCE

TIE PROPOSED UNDERDRAIN INTO

EXISTING FIELD UNDERDRAIN.

FIELD VERIFY LOCATION AND

DEPTH OF EXISTING UNDERDRAIN

LOD

LOD LOD LOD LOD LOD LOD LOD LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LO

D

LO

D

LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LO

D

LO

D

LO

D

LOD LOD LOD LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

8" UNDERDRAIN

TIE PROPOSED 12' FENCE INTO

EXISTING 8' FENCE AT TRANSITION

CONCRETE CURB

TOP OF CURB: 521.90

4" UNDERDRAIN

(ALTERNATE 3)

EXTENT OF GRADING

REPLACE FOUL POLES WITH

POLES PROVIDED BY OWNER

-1 5.

9%

-1 5.

8%

-1 2.

4%

-1 3.

9%

-1 0.

1%

-2.2%

-2.8%

-5 .9

YD-1

YD-2YD-3

521.13 521.13

521.13

521.74 521.63

520.81

521.29

521.13

I-2

10 10 20 FT0

HORIZONTAL SCALE: 1 INCH = 10 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C304

STORMWATER

MATERIALS

A. FABRIC - VINYL COATED STEEL CHAIN LINK FABRIC SHALL BE FURNISHED IN ACCORDANCE WITH ASTM F-668-TYPE

2B. THE STEEL CORE WIRE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A-641-71A. THE COLOR SHALL BE BLACK, A.1-TYPE-STANDARD INDUSTRIAL, 2"X1/8" MESH, 9-GUAGE, 0.14" CORE WIRE DIA., 1290 LB. BREAKLOAD.

B. FRAMING & FITTINGS - ALL STEEL PARTS SHALL BE HOT-DIPPED GALVANIZED AS PER ASTM, PRIOR TO VINYL COATING. THICKNESS OF VINYL COATING SHALL BE 10-14 MILS APPLIED BY FUSION BONDING.

24"

6"

72"

12'

8' SPACING O.C.

TENSION BAR

CONCRETE POST FOOTING

(TYP OF ALL POSTS)

BOTTOM SELVAGE

KNUCKLED

HOG RING

POST CAP (DOME TYPE)

ROUND END & CORNER POST

4" SCHEDULE 80

CHAIN LINK FABRIC

(TOP SELVAGE KNUCKLED)

LINE POST LOOP CAP

COILED SPRING

TENSION WIRE

LINE POST TIE

LINE POST

(ROUND OR "C")

TOP RAILTIE WIRE

CHAIN LINK FENCE - 12' HEIGHT

NOT TO SCALE

2" MESH 9-GA POLYMER COATED CHAIN

LINK FABRIC, COLOR TO BE BLACK;

KNUCKLED TOP & BOTTOM SELVAGES

KNUCKLE SELVAGE

1 5 8" TOP RAIL

1 5 8" MIDDLE RAIL

1 5 8" BOTTOM RAIL

24"

12' HEIGHT CHAINLINK

FENCE POST (TYP.)

FENCE PADDING

(INSTALLED BY OTHERS)

FENCE SECTION A-A

NOT TO SCALE

WARNING TRACK

CONCRETE PADDED FENCE POST

FOUNDATION, SEE DETAIL

NOTE:

PROVIDE 12" OVERLAP OF FABRIC

AASHTO NO. 57

COARSE AGGREGATE

8" HDPE SINGLE WALL

PERFORATED PIPE

CLASS 1

GEOTEXTILE FABRIC

6" 6"

UNDERDRAIN

NOT TO SCALE

12" MIN

COVER

FINISHED GRADE

12"

OVERLAP

8" HDPE SINGLE WALL

PERFORATED PIPE

CLASS 1

GEOTEXTILE FABRIC

12" MIN

COVER

6" WARNING

TRACK MIX (MIN.)

12"

8" EXPOSED @

BACK OF CURB

12" MIN

COVER

18"

12"

8"

24"

5% VARIES

INV: 518.19

ELEV: 521.13

VARIES

EXISTING PAVEMENT

SEE NOTE

PAVEMENT JOINT

NOT TO SCALE

REFERENCE BITUMINOUS PAVEMENT

NOTE

SAWCUT CLEAN, STRAIGHT EDGE IN EX PAVEMENT AND REMOVE

EX MATERIAL. INSTALL NEW PAVEMENT AGAINST EDGE,

FORMING A SMOOTH, FLUSH JOINT. SEAL WITH CRAFCO

ASPAHLT RUBBER TYPE 2 CRAFCO SUPERFLEX, OR EQUIVALENT.

1.5” (9.5MM) SUPERPAVE ASPHALT MIXTURE DESIGN, HMA

WEARING COURSE, PG.64-22, 0 TO 0.3 MILLION ESAL’S

4” (25MM) SUPERPAVE ASPHALT MIXTURE DESIGN, HMA

BINDING COURSE, PG.64-22, 0 TO 0.3 MILLION ESAL’S

6.0" 2A MODIFIED STONE SUBBASECOMPACTED SUBBGRADE

BITUMINOUS PAVEMENT

NOT TO SCALE

4" WIDE SAWN OR

TOOLED CONTROL JOINT,

2 12" MIN DEPTH

SEALANT, 1" DEPTH

8" WIDE PREFORMED EXPANSION

JOINT, FULL DEPTH OF CONCRETE SLAB

PROVIDE TOOLED EDGE

EXPANSION AND CONTROL JOINTS

NOT TO SCALE

NOTE:

SEE DRAWINGS AND SPECIFICATION FOR PLACEMENT OF

ISOLATION AND CONTROL JOINTS FOR CONCRETE.

CONCRETE

SUBBASE

FOUL POLES

(TO BE PROVIDED BY OWNER)

NOT TO SCALE

NOTES:

1. ALL FOUL POLE BASE FOUNDATIONS SHALL BE CAST-IN-PLACE CONCRETE, 3500 PSI

MIN. 28 DAY COMPRESSIVE STRENGTH CONCRETE WITH GRADE 60 REINFORCING STEEL.

2. IF WATER IS PRESENT IN EXCAVATED HOLE, REMOVE BEFORE POURING CONCRETE.

3. FOUNDATION EXCAVATION SHALL BE BY 24" AUGER IN UNDISTURBED OR PROPERLY

COMPACTED FILL PER SPECIFICATIONS.

4. FOUNDATION SHALL HAVE A MINIMUM ALLOWABLE END BEARING OF 2000 PSF.

FOUL POLES

(SEE DETAIL)

FINISHED GRADE

VERTICAL AND HORIZONTAL BARS SHALL

BE FIELD TIED. WELDING NOT PERMITTED.

SUPPORT REINFORCEMENT IN ITS PROPER

LOCATION FROM THE FORMWORK DURING

CONCRETE OPERATION.

2' BELOW FROST LINE

(4) ANCHOR BOLTS 1.25"

DIA. x 42" LONG x 6" HOOK

4-#8 x 8' (MIN) LONG

BARS EQUALLY SPACED

#3 TIES @ 16" O.C. MAX

3"

24"

DIAMETER

3"

TYP

6' - 0"

MINIMUM COVER TYP.

FOUL POLE FOUNDATIONS

NOT TO SCALE

BASE PLATE MOUNTING KIT

(SEE DETAIL)

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C801

DETAILS

3"

CLEAR

PIER FOOTING

(SHOWN AS 24" DIA.)

(6) #6 VERTICAL BARS

EQUALLY SPACED

#3 TIES AT

14" O.C.

EMBEDDED 4" SCH. 80

ASTM F1083 FENCE POST

EXISTING

GRADE

6' -6

M

IN

IM

U M

2'-0" SECTION a a

8" B

EL

O

W B

O T.

O F

FE

N

C E

PO

ST

DESIGN CRITERIA

CONCRETE: 4,000 PSI

REINFORCING: ASTM A615, GRADE 60

ALLOWABLE SOIL LATERAL PASSIVE PRESSURE: 250 PSF/FT

MAXIMUM SOIL LATERAL PRESSURE LIMIT: 1,500 PSF

4" SCH. 80 FENCE POST

(8'-0" MAX O.C. SPACING)

NOTES:

1. FOUNDATIONS SIZED FOR A 12' PADDED (SOLID) FENCE WITH A MAXIMUM

FENCE POST SPACING OF 8'-0" O.C.

DETAIL

TYPICAL PADDED FENCE

POST FOUNDATION

NO SCALE

B S1

10"

3"

CLEAR

PIER FOOTING

(SHOWN AS 60" DIA.)

(24) #7 VERTICAL BARS

EQUALLY SPACED

#3 TIES AT

14" O.C.

EMBEDDED

W16x67 COLUMN

EXISTING

GRADE

'-0

M

IN

IM

U M

5'-0"

SECTION a a

8" B

EL

O

W

BO

T.

O

F C

O

LU

M N

DESIGN CRITERIA

CONCRETE: 4,000 PSI

REINFORCING: ASTM A615, GRADE 60

ALLOWABLE SOIL LATERAL PASSIVE PRESSURE: 250 PSF/FT

MAXIMUM SOIL LATERAL PRESSURE LIMIT: 1,500 PSF

NOTES:

1. SEE BATTER'S EYE STRUCTURE DRAWINGS ON SHEET C804/C805 FOR POST SPACING

AND ABOVE-GRADE STRUCTURE DETAILS.

2. FOUNDATIONS SIZED FOR A 40' HIGH BATTER'S EYE WITH A 36'-4" SOLID

SURFACE HEIGHT.

DETAIL

TYPICAL BATTER'S EYE FOUNDATION

NO SCALE

A

S1

EMBEDDED W16x67 COLUMN

SPACING PER C801

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C802

STRUCTURAL

FULL DEPTH TRENCH RESTORATION

NOT TO SCALE

TRENCH LIMITS

PAVE LAWN

LAWN RESTORATION

AS REQUIRED

SUITABLE BACKFILL COMPACTED IN 8"

LIFTS TO 95% MAXIMUM DRY DENSITY

12"

MIN

12" MIN

12"

MIN

PIPE

O.D.

6" MIN

DEPTH

VARIES

DEPTH

VARIES

PennDOT 2A COARSE AGGREGATE

COMPACTED IN 8" LIFTS TO 95%

MAXIMUM DRY DENSITY

BITUMINOUS PAVEMENT, SEE

PLAN FOR TYPE; SEE DETAIL

UNDISTURBED

EARTH

AASHTO #57

COARSE

AGGREGATE

UTILITY LINE; REFERENCE

PLAN FOR TYPE AND SIZE

NOTES:

1. PLACEMENT OF BACKFILL IN LIFTS UP TO 8" THICK IS ALLOWED WHEN VIBRATORY COMPACTION

EQUIPMENT IS BEING UTILIZED. USE MECHANICAL TAMPERS OR OTHER ACCEPTABLE

COMPACTION EQUIPMENT WITH CONSISTENT APPLICATION FORCE SO NO DAMAGE TO THE PIPE

OCCURS. BACKFILL WILL BE TESTED FOR 100% COMPACTION WHEN PLACED IN PAVED AREAS.

2. COMPACT THE TOP 3' OF BACKFILL MATERIAL TO 100% STANDARD PROCTOR DENSITY.

3. FOLLOW OSHA SAFETY REQUIREMENTS FOR SLOPE LAYBACKS OR PROVIDE SHORING AS REQUIRED.

NOTES:

1. PROVIDE MANHOLE STEPS FOR INLETS OVER 4' DEEP IN ACCORDANCE WITH PENNDOT PUBLICATION 72, RC-39M.

2. REFERENCE PENNDOT PUBLICATION 72, RC-45M, FOR ADDITIONAL DETAILS ON THE INLET FRAME AND GRATE

AND PRECAST CONCRETE GRADE ADJUSTMENT RINGS.

3. REFERENCE PENNDOT PUBLICATION 72, RC-46M, FOR ADDITIONAL DETAILS ON THE STANDARD INLET BOX.

4. REFERENCE PENNDOT PUBLICATION 72, RC-46M, FOR ADDITIONAL DETAILS ON THE TYPE 4 INLET BOX.

4"

6" (TYP.)

36"

6" (TYP.)

4"

2"

STRUCTURAL STEEL GRATE BICYCLE SAFE

PIPE OPENING

INSIDE FACE = 25"Ø MAX.

OUTSIDE FACE = 26"Ø MAX.

STANDARD INLET BOX

PIPE OPENING

PINSIDE FACE = 461

4"Ø MAX

OUTSIDE FACE = 471

4" MAX

6 TRANSVERSE RODS

22 BEARING BARS

PRECAST CONCRETE

GRADE ADJUSTMENT RING,

3" MIN - 10" MAX

A

TYPE M METAL TOP

INLET BOX

2 SPA @ 18"

(CENTERED)

4"

27"

2" 11

2"

4"

2" 41

2"

4"

16"

MIN LAP

LENGTH (TYP)

2"

2"

24"

2"

2"

36"

1 SPA @ 16"

(CENTERED)

8" STUDS OR #3 BENT

BAR ANCHORS (TYP)

2" 11

2"

4"6" 6"

2"11

2"TOP OF GRATE 21

2" 41

2" 11 2" 41

2"11 2"

24"6" 6"

2"

TOP OF GRATE

8" MIN

12" MAX

2"

2"

8"Ø x 21

2" STUDS

#3 @ 9" (TYP)

CLEAR (TYP)

PRECAST = 11

2"

CAST-IN-PLACE = 2"

2" MIN

3" MAX

2" MIN

3" MAX

#4 BARS (TYP)

DETAIL 1

SECTION A-A SECTION B-B

PLAN VIEW

B

A

B

BICYCLE SAFE STEEL GRATE

STANDARD INLET BOX - TYPE M CONCRETE TOP

NOT TO SCALE

DRAIN BASIN INLINE DRAIN

4" MIN ON 8" - 24"

6" MIN ON 30"

THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER

GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,

CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.

BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE

PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM

D2321.

THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR

OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS

OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN

ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE

INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN

ACCORDANCE WITH ASTM D2321.

TOP SOIL TOP SOIL

ADAPTER

ANGLES

VARIABLE

0° - 360°

VARIES (REFER TO

PIPE SCHEDULE)

(3) VARIABLE SUMP DEPTH

ACCORDING TO PLANS

(6" MIN. ON 12" - 24", 10" MIN. ON 30"

& 12" MIN. ON 36"

BASED ON MANUFACTURING REQ.)

12" SUMP DEPTH

VARIES

(REFER TO PIPE

SCHEDULE)

VARIABLE INVERT HEIGHTS

AVAILABLE (REFER TO PIPE

SCHEDULE)

THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR

OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS

OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN

ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE

INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN

ACCORDANCE WITH ASTM D2321.

WATERTIGHT JOINT

(CORRUGATED HDPE SHOWN)

VARIOUS TYPES OF INLET & OUTLET ADAPTERS

AVAILABLE: 4" - 36" FOR CORRUGATED HDPE (ADS

N-12/HANCOR DUAL WALL, ADS/HANCOR SINGLE WALL),

N-12 HP, PVC SEWER (EX: SDR 35), PVC DWV (EX: SCH 40),

PVC C900/C905, CORRUGATED & RIBBED PVC

8" OR 12" DOME GRATE -TYPE B, SEE DETAIL

FRAME & GRATE TO MATCH BASIN O.D.

(SEE PLAN FOR LOCATION OF 12" DOME GRATE)

NOTE:

1. NYLOPLAST DRAIN BASINS SHALL BE INSTALLED PER MANUFACTURER RECOMMENDATION.

NYLOPLAST DRAIN BASIN WITH

PEDESTRIAN GRATE INSTALLATION DETAIL

NOT TO SCALE

NYLOPLAST DRAIN BASIN AND INLINE DRAIN

NONTRAFFIC INSTALLATION DETAIL

NOT TO SCALE

NOTES:

QUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05

PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT

LOCKING DEVICE AVAILABLE UPON REQUEST

A A

SECTION A-A

8"/12" DOME GRATE - TYPE B

NOT TO SCALE

4" - (8" DOME)

5" - (12" DOME)

Ø 8.96" (8" DOME)

Ø 13.38" (12" DOME)

(SEE PLAN FOR LOCATION OF 12" DOME GRATE)

8" OR 12" DOME GRATE

(SEE PLAN FOR LOCATION OF 12" DOME GRATE)

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C803

F F

G

G

B

A

TOP TRIM LOW RIBBED PROFILE (3

4" H RIBS SPACED 6" O.C.) EXPOSED FASTENER

METAL WALL PANEL ON FRONT USING MBCI PBU 36" W 26* GAUGE

GALVALUME COATED STEEL PANELS WITH SIGNATURE 300 TWO-COAT

FLUOROPOLYMER FINISH. PANELS FIELD ASSEMBLED WITH SIDE LAPS

AND THROUGH FASTENED TO HORIZONTAL GIRTS. RELATED METAL

TRIM AND ATTACHMENT HARDWARE INCLUDED.

DETAIL A

36" 6" 3/4"

RIBBED PANEL PROFILE

DETAIL B

SIDE TRIM

4" SQUARE X 11 GAUGE

STEEL HORIZONTAL GIRTS

BOLTED TO WELDED STEEL

SUPPORT BRACKETS

SIDE WINDSHIELD

W16 X 67

EXTERIOR COLUMNS

W16 X 77

INTERIOR COLUMNS

LIGHT-COLORED ACRYLIC/POLYESTER

BACKER FINISH ON BACKSIDE OF

SURFACE PANELS

FINISH GRADE

10'-0"

BOTTOM BEAM

ELEV O.C.

3'-8"

36'-4"

W12 X 26

TOP BEAM

W12 X 26

BOTTOM BEAM

6" TO BEAM SET DOWN

40'-0"

80'-0"

STANDARD "HARBOR BLUE" POWDER COATED FINISH ON FRAMING COMPONENTS

ENGINEERED TO MEET ASCE 7-16 WIND

RATING UP TO 105 MPH, EXPOSURE B

FINISH GRADE

18'-1"

BEAM LENGTH

19'-1 5/16"

INTERIOR COLUMN

SPACING

19'-1 1/4"

EXTERIOR COLUMN

SPACING

ELEVATION VIEW

(SURFACE PANELS REMOVED FOR CLARITY)

8" X 2-1/4" L, GRADE A325 HD GALV.

HEX HEAD BOLT; W/(1) GRADE A563

DH GALV. HEAVY HEX NUT AND (2) 5 8"

GALV. F436 FLAT WASHER, 1-5/16" OD

1/2" X 5-1/2" GRADE 5 ECOGUARD FINISHED

HEX CAP SCREW WITH (2) FLAT WASHERS, (1)

LOCK WASHER, AND (1) GRADE 5 HEX

(SECURE GIRT TUBE TO ATTACHMENT ANGLE)

L 4" X 4" X 38" X

6"L EXTERIOR COLUMNS

7-1/2"L INTERIOR COLUMNS

SECTION G-G

GIRT ATTACHMENT ANGLES TO COLUMNS.

BEVEL GROVE WELD AT TOP TO PREVENT

INTERFERENCE WITH GIRT.

4"

BEAMS TO ATTACHMENT PLATES (TYP.)1

4"

12"

SECTION F-F

FRONT PANELING

HIDDEN FOR CLARITY

SIDE 16 GA FORMED STEEL WINDSHIELD,

POWDER COATED "HARBOR BLUE"

PL 12" A36 (TYP.)

1' 3 11

16" TYP

BOTH SIDES OF ATTACHMENT

PLATES TO COLUMN TYP

4"

HSS 4" X 4" 11 GA GIRTS

A500 GRADE B - TYP

48" O.C.

TYP

20'- 10 116"

EXTERIOR GIRT TUBES

80'-0"

19'- 0 116"

INTERIOR GIRT TUBES

36'-4"

SURFACE HEIGHT

40'-0"

EMBEDMENT PER SHEET C802

40' H X 80' W SOLID SURFACE BATTER'S EYE

(ALTERNATE 1)

NOT TO SCALE

NOTES:

1. ENGINEERED TO MEET ASCE 7-16 WIND RATING UP TO 105 MPH, EXPOSURE B

2. ALL W SHAPE STRUCTURAL MEMBERS CONFORM TO ASTM A922

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C804

ALTERNATE 1

F F

G

G

B

A

TOP TRIM LOW RIBBED PROFILE (3

4" H RIBS SPACED 6" O.C.) EXPOSED FASTENER

METAL WALL PANEL ON FRONT USING MBCI PBU 36" W 26* GAUGE

GALVALUME COATED STEEL PANELS WITH SIGNATURE 300 TWO-COAT

FLUOROPOLYMER FINISH. PANELS FIELD ASSEMBLED WITH SIDE LAPS

AND THROUGH FASTENED TO HORIZONTAL GIRTS. RELATED METAL

TRIM AND ATTACHMENT HARDWARE INCLUDED.

DETAIL A

36" 6" 3/4"

RIBBED PANEL PROFILE

DETAIL B

SIDE TRIM

4" SQUARE X 11 GAUGE

STEEL HORIZONTAL GIRTS

BOLTED TO WELDED STEEL

SUPPORT BRACKETS

SIDE WINDSHIELD

W14 X 61

EXTERIOR COLUMNS

W14 X 68

INTERIOR COLUMNS

LIGHT-COLORED ACRYLIC/POLYESTER

BACKER FINISH ON BACKSIDE OF

SURFACE PANELS

FINISH GRADE

10'-0"

BOTTOM BEAM

ELEV O.C.

3'-8"

32'-4"

W12 X 26

TOP BEAM

W12 X 26

BOTTOM BEAM

6" TO BEAM SET DOWN

36'-0"

60'-0"

STANDARD "HARBOR BLUE" POWDER COATED FINISH ON FRAMING COMPONENTS

ENGINEERED TO MEET ASCE 7-16 WIND

RATING UP TO 105 MPH, EXPOSURE B

36' H X 60' W SOLID SURFACE BATTER'S EYE

(ALTERNATE 2)

NOT TO SCALE

FINISH GRADE

18'-1"

BEAM LENGTH

19'-1"

INTERIOR COLUMN

SPACING

19'-1"

EXTERIOR COLUMN

SPACING

ELEVATION VIEW

(SURFACE PANELS REMOVED FOR CLARITY)

8" X 2-1/4" L, GRADE A325 HD GALV.

HEX HEAD BOLT; W/(1) GRADE A563

DH GALV. HEAVY HEX NUT AND (2) 5 8"

GALV. F436 FLAT WASHER, 1-5/16" OD

1/2" X 5-1/2" GRADE 5 ECOGUARD FINISHED

HEX CAP SCREW WITH (2) FLAT WASHERS, (1)

LOCK WASHER, AND (1) GRADE 5 HEX

(SECURE GIRT TUBE TO ATTACHMENT ANGLE)

L 4" X 4" X 38" X

6"L EXTERIOR COLUMNS

7-1/2"L INTERIOR COLUMNS

SECTION G-G

GIRT ATTACHMENT ANGLES TO COLUMNS.

BEVEL GROVE WELD AT TOP TO PREVENT

INTERFERENCE WITH GIRT.

4"

BEAMS TO ATTACHMENT PLATES (TYP.)1

4"

12"

SECTION F-F

FRONT PANELING

HIDDEN FOR CLARITY

SIDE 16 GA FORMED STEEL WINDSHIELD,

POWDER COATED "HARBOR BLUE"

PL 12" A36 (TYP.)

1' 3 11

16" TYP

BOTH SIDES OF ATTACHMENT

PLATES TO COLUMN TYP

4"

HSS 4" X 4" 11 GA GIRTS

A500 GRADE B - TYP

48" O.C.

TYP

20'- 10 116"

EXTERIOR GIRT TUBES

60'-0"

19'- 0 116"

INTERIOR GIRT TUBES

32'-4"

SURFACE HEIGHT

36'-0"

NOTES:

1. ENGINEERED TO MEET ASCE 7-16 WIND RATING UP TO 105 MPH, EXPOSURE B

2. ALL W SHAPE STRUCTURAL MEMBERS CONFORM TO ASTM A922

EMBEDMENT PER SHEET C802

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

C805

ALTERNATE 2

BOX

ELECTRIC

METER

ELECTRIC

METER

ELECTRIC

METER NO ID

PPL 19369 N39294

PPL 19370 N39297

PPL 19361 N39296

PPL 19361 N39299

PPL 19355 N39307

PPL 19342 N39299

X X

X X

X

X

X X

X X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X X

X X

X

X

X

X

X

X

X

XXXXXXXX

X

X

X

X

X

X

X X

X

X

X

X

X

BLAINE ST.

NE

W

CO

M

ER

A

VE

15" ALLEY

H

AM

M

ON

D

PL

N/F

CITY OF WILLIAMSPORT

TP# 70-013-302

DB 239 PG 471

N /F

CO

M

M

ON

W

EA

LT

H

O F

PA

TP

-0

-1

N/F

DEASE, MARY M. ET AL

TP# 70-013-125

" A

LL

EY

N/F

WILLIAMS, RODNEY S. ET AL

TP# 70-013-129

N/F

LING LU

TP# 70-013-130

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-130

N/F

PAULHAMUS, LARRY ET AL

TP# 70-013-111 N/F

VICK, MICHAEL S.

TP# 70-013-110

N/F McCLURE, WAYNE J. ET AL

TP# 70-013-109

N/F

BOROSCO, JOSEPH A. ET AL

TP# 70-013-108

N/F

BOROSCO, JOSEPH A. ET AL

TP# 70-013-107 N/F

KENNEDY, TANYA Y. ET AL

TP# 70-013-107

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OH

OHOH

X

X

X

X

X

X

X

X

X

PPL 19376 N39266

PPL 19357

N39259

PPL 19345 N39255

INLET RIM 524.54'

(N) 12" RCP 520.15'

(E) 12" 520.09'

(S) 12" RCP 519.97'

INLET RIM 518.82'

(N) 6" SLCPP 516.97'

(S) 12" SLCPP 516.40'

INLET RIM 518.95'

(N) 6" SLCPP

(S) 6" SLCPP

INLET RIM 519.45'

(N) 8" SLCPP 517.58

(W) 6" SLCPP 517.65'

(S) 8" SLCPP 517.54'

IRRIGATION SYSTEM WITH

6" LIDS

UE

UE

UE

UE

UE

UE

UE

OH

OH

OH

OH

OH

OH

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

OH

OH

OH

UE

UE

UE

UE

UE

UE

UE

UE

UE

UNKNOWN

UTILITY

X

X

SCORE

BOARD

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

X

X

X

X

X X

X

UNDERGROUND

COMMUNICATION

LINE

50' ROW

EDGE OF PAVEMENT

EDGE OF PAVEMENT

6" PVC

FIELD DRAIN

BENCHMARK

REBAR WITH LIVIC CAP

ELEV: 525.77

STADIUM

LIGHTS

FOUL POLE

FOUL POLE

STADIUM

LIGHTS

STADIUM

LIGHTS

LAYDOWN AREA

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

XX

X

STADIUM

LIGHTS

PPL 19352 N39297

UE UE UE UE UE

X X

X X

X

X

X

X

X

X

X

X

XXXXXXXX

LOD LOD LOD LOD LOD LOD

LOD

LOD

LOD

LOD

LOD

LO

D

LO

D

LO

D

LO

D

LOD

LO

D

LO

D

LO

D LOD

LOD

LOD

LOD

LOD

LOD LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LODLOD

LOD

LODLODLOD

LOD

LOD

LOD

LOD

LOD

LOD

ROCK CONSTRUCTION ENTRANCE

IP

IP

COMPOST FILTER SOCK

CONCRETE WASHOUT

FILTER BAG INLET

PROTECTION

FILTER BAG INLET

PROTECTION

PAVEMENT

RESTORATION

8" UNDERDRAIN

CONNECT UNDERDRAIN

TO 12" NYLOPLAST

YARD DRAIN

TYPE M INLET

12" SLCPP

12" SLCPP

IP

FILTER BAG INLET

PROTECTION

TYPE M INLET

CUT AND CONNECT EXISTING

PIPES INTO NEW INLET

PROTECT

UNDERGROUND LINES

PROTECT

UNDERGROUND LINES

30 30 60 FT0

HORIZONTAL SCALE: 1 INCH = 30 FEET

N

2ND FLOOR

635 N LOYALSOCK AVENUE

MONTOURSVILLE, PA 17754

PHONE: 888.987-1993

w w w . l i v i c c i v i l . c o m

SHEET NO.

SHEET TITLE

RE

V

DA

TE

CO

M

M

EN

TS

BY

CH

KD

IS

SU

E / R

EV

IS

IO

N

S

PROJECT

CLIENT

PROJECT No:

DRAWN BY: CHECKED BY:

SCALE:

DATE:

AS SHOWN

PHONE:

COUNTY

PENNSYLVANIA

ALL CONTENTS OF THIS PLAN ARE PROPRIETARY

AND SHALL NOT BE REPRODUCED OR UTILIZED FOR

A N Y P U R P O S E W I T H O U T P R I O R W R I T T E N

AUTHORIZATION FROM LIVIC CIVIL, LLC. ONLY

A P P R O V E D , S E A L E D P L A N S S H A L L B E

IMPLEMENTED FOR CONSTRUCTION PURPOSES.

© 2 0 2 5 L I V I C C I V I L , L L C

1234-05

BOWMAN FIELD

OUTFIELD FENCE

REPLACEMENT

1500 W 3RD STREET

WILLIAMSPORT, PA, 17701

(570) 326-4684

LYCOMING

ADK

CITY OF

WILLIAMSPORT

DIS

CITY OF

WILLIAMSPORT

8.

.2

IS

SU

ED

F

O R

BI

D

DI

S

AD

K

ES501

EROSION AND

SEDIMENT

CONTROL PLAN

50' MIN.

FT.

EXISTING ROADWAY

20'

MIN.

EX

IS

TI

N

G R

O

AD

W

AY

PROFILE

PLAN VIEW

NOTES:

REMOVE TOPSOIL PRIOR TO INSTALLATION OF ROCK CONSTRUCTION ENTRANCE. EXTEND ROCK OVER FULL

WIDTH OF ENTRANCE.

RUNOFF SHALL BE DIVERTED FROM ROADWAY TO A SUITABLE SEDIMENT REMOVAL BMP PRIOR TO

ENTERING ROCK CONSTRUCTION ENTRANCE.

MOUNTABLE BERM SHALL BE INSTALLED WHEREVER OPTIONAL CULVERT PIPE IS USED AND PROPER PIPE COVER AS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .