This document appears to be a detailed layout drawing and port configuration for several interconnected ultra-high vacuum (UHV) chambers, including a FIM chamber, loadlock chamber, and sample preparation chamber, that are required for a new scanning probe microscopy (SPM) laboratory at the National Institute of Standards and Technology (NIST).
The key details include the specific port configurations, focal point coordinates, flange types, and tube sizes for each chamber. This information is provided to support a federal contract opportunity solicitation for the procurement of these UHV chamber components. The solicitation, numbered 1333ND24QNB680331, is seeking nine vacuum chambers/components to be interconnected for the SPM laboratory to perform sample and probe preparation, as well as SPM measurements. The Department of Commerce's National Institute of Standards and Technology is the responsible federal agency for this requirement.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| UHV_chamber_STEP_files.zip | ZIP file | |
| Requirements.docx | DOCX document | |
| 1333ND24QNB680331.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIM chamber Port configuration, Layout drawing on page 1 of Chambers_all.pdf
Port # CF flange
OD
Flange type/bolt holes
Tube Size OD (inches) focal point focal length
(inches) azimuthal angle
(degrees) polar angle (degrees) Comments (flange use)
1 12 fixed / tapped 10 A 6.62 NA 180 evap source 2 2.75 fixed / blind tapped 2.75 A 8.435 270 90 wobblestick 3 6 fixed/ tapped 4 A 10.03 270 50 viewport 4 8 fixed / tapped 6 A 7.38 315 90 FIM flange/ xlator 5 2.75 rotatable/ clearance 1.75 A 7 0 90 tip heater z xlator 6 6 fixed/ tapped 4 A 10.03 0 50 viewport 7 2.75 fixed/ tapped 1.75 A 7 45 90 8 2.75 fixed/ tapped 1.75 B 7 45 90 9 6 rotatable/ clearance 4 A 9.25 90 90 to prevac chamber 10 2.75 fixed/ tapped 1.75 A 10.5 90 45 11 6 fixed/ tapped 4 A 6.95 135 90 turbo port 12 2.75 fixed/ tapped 1.75 B 7 135 90 gauge 13 4.5 rotatable/ clearance 2.75 A 7 180 90 14 6 rotatable/ clearance 4 A 7.5 225 90 15 2.75 fixed/ tapped 1.75 B 7 225 90 16 8 fixed / clearance 6 B 6.63 NA 0 ion pump
Focal Pt. Coordinates (X, Y, Z) (inches)
A (0, 0, 6.62) B (0, 0, 11.62)
Loadlock chamber Port configuration, Layout drawing on page 4 of Chambers_all.pdf
Port # CF flange
OD
Flange type/bolt holes
Tube Size OD (inches) focal point focal length
(inches) azimuthal angle
(degrees) polar angle (degrees) Comments (flange use)
1 8 rotatable/clearance 6 A 4.5 NA 180 ion pump 2 6 fixed / clearance 4 A 7.012 90 90 to 1st loadlock 3 2.75 fixed / clearance 1.75 A 5 0 90 extra 4 2.75 fixed / blind tapped 2.75 A 7 135 90 wobblestick 5 6 rotatable/ clearance 4 A 5 270 90 to rotary chamber 6 2.75 fixed/ clearance 1.75 A 5 200 90 extra 7 6 fixed / tapped 4 B 8.887 45 50 viewport 8 6 fixed / tapped 4 B 8.887 135 50 viewport 9 2.75 fixed / clearance 1.75 C 5 315 90 gauge port 10 4.5 fixed / clearance 2.75 C 5 225 90 getter pump?
11 8 fixed/ clearance 6 C 5 NA 0 manipulator
Focal Pt. Coordinates (X, Y, Z) (inches)
A (0, 0, 4.5) B (0, 0, 6.232) C (0, 0, 10.5)
| FIM_chamber |
| FIM_source_flange |
| Loadlock_chamber |
| Sample_Prep_chamber |
| Sample_Prep_pump_nipple |
| sample_prep_source_flange |
| Sample_Prep_top_flange |