This document is a set of questions and answers related to a federal contract opportunity for modular office furniture, layout, and installation. The contract is a small business set-aside with a NAICS code of 337214 and a size standard of 1,100 employees.
The key details are:
- The Office of National Marine Sanctuaries (ONMS) located in San Luis Obispo, California requires modular office furniture, layout, and installation services.
- Vendors must make a site visit to the NOAA ONMS Bldg 82-C Lab Space 1C1 at California Polytechnic State University to inspect the space.
- The contract includes specifications for the modular office layout, including required ceiling heights, wall types, power and data requirements, furniture items, and storage needs.
- Vendors must provide a pricing quote that meets the detailed technical requirements outlined in the Statement of Work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_1305M224Q0334_Amd_0001.pdf | ||
| Sol_1305M224Q0334.pdf | ||
| Past_Performance_Questionnaire.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAM 1305M224Q0334 MODULAR OFFICE FURNITURE, LAYOUT AND INSTALLTION
Office Space Planners 9/3/2024 877-918-1947
1. Should the 6’x9’ medium height modular offices be connected together or independent
Due to the limited space available in the ‘main office’, NOAA suggests the medium height modular offices be connected together.
2. Will the 6’x9’ medium height modular offices be connected to fixed permanent walls?
The medium height can be freestanding or anchored to fixed permanent walls.
3. Do the panels for the 6’x9’ medium height modular offices need to be powered and if so will they be powered by a base or ceiling feed?
NOAA believes existing permanent wall sockets are sufficient. A site visit is highly recommended.
4. Do you happen to have a floor plan of the space that you could provide, including a sketch identifying where the 84” and 60” high walls are to be located?
Floor plan included for space 1C-1. NOAA suggests the high wall office be placed near the windowed side of the suite. See drawing. A site visit is highly recommended.
5. Do you want us to include one ore two 30”D x 72”W flip top tables?
Two flip top tables are preferred.
6. Are we to provide storage and dry erase boards? If so please provide quantity, type and quantity.
One dry erase board is requested as part of each office. A lateral file or similar for each office. Additional horizontal storage in a common area sufficient to place a copier/printer on top. Vendors to propose based on current storage standards and outfitting for offices.
7. Are we to include a hardwired sound masking system for the 1,100 square foot space? If so, what is the ceiling height and is there an acoustic ceiling or is open to structure? Pictures of the space would be helpful to ensure we are providing an accurate quote.
Hardwired sounds masking is required particularly in the main office space. The space contains and open ceiling with ventilation tubing. See drawing for heights. Prospective vendors should verify ceiling structure layout and electrical via a site visit.
8. For the lobby space do you want two lounge chairs or one two seat sofa?
Two lounge chairs preferred.
9. For the lobby space should the desk be height adjustable or seated height?
SAM 1305M224Q0334 MODULAR OFFICE FURNITURE, LAYOUT AND INSTALLTION
Office Space Planners 9/3/2024 877-918-1947
Seated height is acceptable for the lobby space.
10. Will the existing Steelcase furnishings currently located in the space be used for any of the items outlined for the main office or lobby spaces? Meaning that we will not provide all of the furnishings outlined under ‘In the main office space’ and ‘In the vestibule/lobby space’
Based on a survey by NOAA, the existing Steelcase furniture will be used only in the main office area. Vendors should verify via a site visit.
11. Does the building have a loading dock?
No, but not necessary as the building is small and the NOAA suite is the first door on the right just past the main entrance doors.
12. If no loading dock, where will we load/offload the truck
At the curb of the double front doors of the first/lower floor of the building. The NOAA suite is the first door on the right inside those main doors.
13. Approximately how far is it from the truck parking location to the install location?
Less than 50 feet
14. Are there any stairs that the product will need to go up or down to reach the installation location? If so, how many?
No stairs except a regular height curb from the driveway to the entrance sidewalk where the truck will unload.
15. Do we have access to a passenger or a freight elevator to use for delivery to the installation location (if applicable)?
N/A
M
t. Bishop Road
M
t. Bishop Road
PROJECT SITE
ELECTRICAL ENGINEERING:
PROJECT TEAM INDEX
BILL KANNE, PE #E114478
OMNI DESIGN GROUP, INC.
689 TANK FARM ROAD, SUITE 140
SAN LUIS OBISPO, CALIFORNIA 93401
805.544.9700
ARCHITECTURE: THOMAS REAY, ARCHITECT CA#19442
OMNI DESIGN GROUP, INC.
CALIFORNIA LICENSED ARCHITECT #C19442
689 TANK FARM ROAD, SUITE 140
SAN LUIS OBISPO, CALIFORNIA 93401
805.544.9700
CAL POLY PROJECT MANAGER: MIKE HOGAN, PROJECT MANAGER
CAL POLY FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
805.756.7503
MECHANICAL ENGINEERING: JAMES VAN DEVANTER, LIC #: M31203
JVA MECHANICAL ENGINEERING
1023 NIPOMO STREET, SUITE 200
SAN LUIS OBISPO, CA 93401
PHONE: (805) 543-3190
FAX: (805) 543-3165
G1.1 DSA ACCESS COMPLIANCE
A2.0 INTERIOR ELEVATIONS & SECTION
A1.0 FLOOR PLAN & REFLECTED CEILING PLAN
DEFERRED SUBMITTALS
DEFERRED SUBMITTALS:
THE DESIGN/BUILD CONTRACTOR AND THE UNIVERSITY ARE RESPONSIBLE FOR OBTAINING ANY
ADDITIONAL PERMITS OR APPROVALS AS REQUIRED BY ANY AND ALL AGENCIES HAVING JURISDICTION
PRIOR TO THE INSTALLATION OF THE FOLLOWING ITEMS.
ITEM 1 - REVISONS TO EXISTING AUTOMATIC FIRE SPRINKLERS
TECHNOLOGY PARK PILOT PROJECT BUILDING
TENANT IMPROVEMENT FOR LAB SPACE 1C1
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA
PLATINUM PERFORMANCE
PARTIAL CAMPUS MAP
SCALE: 1"=400'
E1.0 ELECTRICAL DISTRIBUTION PLAN
MP1.1 GENERAL NOTES, ABBREVIATIONS & SPECIFICATIONS
COVER SHEET
G1.0
COVER SHEETG1.0
TENANT: PLATINUM PERFORMANCE
MARK HERTHEL, PRESIDENT
67 COMMERCE DRIVE, UNIT 100
BUELLTON, CALIFORNIA 93427
800.553.2400
LEASING AGENT: JIM DUNNING
CALIFORNIA CENTRAL COAST RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
805.756.5551
SCOPE OF WORK
E1.1
E1.2 PANEL SCHEDULES & FIRE DETECTION PLAN
T24 TITLE 24 ENERGY ANALYSIS REPORT
MP2.1 SCHEDULES & DETAILS
MP3.1 MECHANICAL / PLUMBING FLOOR PLANS
T24 TITLE 24 COMPLIANCE DOCUMENTATION
A3.0 OPENING SCHEDULE & DETAILS
THE SCOPE OF WORK FOR THIS PROJECT IS A TENANT IMPROVEMENT OF LAB SPACE 1C1 OF ALL INTERIOR ELEMENTS CONTAINED WITHIN THE "LIMIT OF WORK" LINE (REFER TO SHEET A1.0). ALL INTERIOR ELEMENTS HAVE BEEN DESIGNED TO PROVIDE ADA COMPLIANT ACCESS TO ALL OFFICE AND WORK SPACES AND
EXITS.
THE SCOPE OF WORK SPECIFICALLY DOES NOT INCLUDE ANY INTERIOR IMPROVEMENTS WITHIN EXISTING SHELL BUILDING OR WORK OUTSIDE OF THE DEFINED LIMIT OF WORK BOUNDARY. FURNITURE, FIXTURES AND
EQUIPMENT (FF&E) IS ALSO NOT INCLUDED IN THE SCOPE OF WORK.
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
LIGHTING AND POWER PLAN
NORTH PARKING AREA
(34) SPACES
SECOND FLOOR
ENTRANCE
SECONDARY FIRST
FLOOR ENTRANCE
PA
RK
IN
G
NO
PARKING
NO
EXISTING PARKING
(10) SPACES
EXISTING VAN AND REGULAR
ACCESSIBLE PARKING SPACES
SERVICING FIRST FLOOR.
(DSA #110735)
PRIMARY ACCESSIBLE
PATH OF TRAVEL TO
FIRST FLOOR
EXISTING VAN AND REGULAR
ACCESSIBLE PARKING SPACES
SERVING SECOND FLOOR.
(DSA #110735)
PRIMARY ACCESSIBLE PATH OF
TRAVEL TO TENANT IMPROVEMENT
FROM ACCESSIBLE PARKING.
(DSA #110735)
PROPOSED
TENANT
IMPROVEMENT
1,168 SF
FIRST FLOOR EXTERIOR
COURTYARD
UP
UP
TELECOM
EAST LOBBY
MAINTENANCE
SHOWER
ELEVATOR
DSA #110735
LOBBY
DSA #110735
ENTRY
BREAKROOM
DSA #110735
CONFERENCE
DSA #110735
LAB AREA 1A
ELECTRICAL ROOM
LAB AREA 1C1
LAB AREA 1B
HALL
EQUIP
COVERED ENTRY
HALL
TO SOUTH PARKING AREA
TO EAST PARKING AREA
BRIDGE ABOVE
WOMENS
MENS
UNIMPROVED FUTURE
TENANT SPACE
DRINKING FOUNTAIN
DSA #110735
DSA #110735 DSA #110735
DSA #110735
LAB AREA 1C2
UNIMPROVED FUTURE
TENANT SPACE
LAB SPACE
1A-105
LAB SPACE
1A-104
LAB SPACE
1A-103
LAB SPACE
1A-102
LAB SPACE
1A-101
COMMON HALL
1A-100
DSA #111709
LAB AREA 1E
DSA #111709
LAB AREA 1D
DSA #XXXXX
PROJECT LOCATION
ON FIRST FLOOR
BRIDGE
ELEVATOR
DSA #110735
TELECOM.
LAB AREA 2B
MENS
WOMENS
EXTERIOR DECK
DSA #110735
HALL
MAINTENANCE
UNIMPROVED FUTURE
TENANT SPACE
DSA #110735
DSA #110735
LAB AREA 2A
EXIT MAXIMUM OVERALL
DIAGONAL DIMENSION
DISTANCE BETWEEN
EXITS
LOBBY
DSA #110735
EXIT
DSA #111369
DSA ACCESS
COMPLIANCE
G1.1
FIRST FLOOR PLAN
SCALE: 1/16" = 1'-0"
12SECOND FLOOR PLAN
SCALE: 1/16" = 1'-0"
34SITE PLAN
SCALE: 1" = 40'
REFERENCE NOTES
CODE COMPLIANCE, NON-STRUCTURAL PROVISIONS
PROPOSED TENANT IMPROVEMENT OCCUPANCY GROUP CLASSIFICATION - GROUP B (CBC SECTION 304)
AREA OF TENANT IMPROVEMENT 1,167.2 GROSS
1,123.9 NET
TOTAL OCCUPANCY LOAD 29 (CBC TABLE 1004.1.1)
EXISTING BUILDING - EXITS REQUIRED 1 (CBC TABLE 1015.1)
OCCUPANCY GROUP CLASSIFICATION GROUP B (CBC SECTION 304)
FIRE SPRINKLER SYSTEM REQUIRED NO REQUIREMENT FOR GROUP B OCCUPANCIES.
(PER CBC SECTION 903.2)
FIRE SPRINKLER SYSTEM PROVIDED YES
CODE MODIFICATIONS USED WITH NON-REQUIED SPRINKLER SYSTEMS. SECTION 1017.1 ELIMINATION OF
CORRIDOR FIRE RESISTANCE RATING..
EXISTING SHELL BUILDING CONSTRUCTION TYPE TYPE VB
ALLOWABLE HEIGHT (TABLE 503) 3 STORIES
ALLOWABLE AREA PER STORY (TABLE 503) 18,000 SQUARE FEET
EXISTING SHELL HEIGHT 2 STORIES
EXISTING SHELL AREA (PER STORY) 14,722 SF FIRST FLOOR
TOTAL EXISTING SHELL AREA 25,330 SF FEET
SPECIAL PROVISIONS TO BE APPLIED FOR NONE
HEIGHT OR AREA (SECTION 509)
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
(TABLE 601) = NONE REQUIRED PER FOOTNOTE e AUTOMATIC FIRE SPRINKLER SUBSTATION.
BUILDING LOCATION ON SITE: CLOSEST ADJACENT BUILDING IS 64 FEET AWAY, NO PROPERTY LINES ON
CAMPUS. NO REQUIREMENT FOR EXTERIOR WALL OR OPENING PROTECTION DUE TO PROXIMITY.
INCIDENTAL USE AREAS (TABLE 508.2) NONE PER TABLE 508.2
TYPICAL OCCUPANT LOAD FACTOR (TABLE 1004.1.1) = 100 SF/OCCUPANT
(FUNCATION OF SPACE : BUSINESS AREA
CONFERENCE ROOM = 15 SF/OCCUPANT
BREAK ROOM = 15 SF/OCCUPANT
LOCKER ROOM = 50 SF/OCCUPANT
SECOND FLOOR EXTERIOR DECK = 20 SF/OCCUPANT*
(*USED ONLY BY BUILDING OCCUPANTS, SEE SECTION 1004.8)
NUMBER OF EXITS REQUIRED (TABLE 1015.1) = 49 MAXIMUM WITH ONE EXIT
B OCCUPANCY
24CODE COMPLIANCE
10,608 SF SECOND FLOOR
APPLICABLE CODES, RULES, AND REGULATIONS:
1. THE 2010 CALIFORNIA BUILDING CODE -- TITLE 24 AS ADOPTED BY THE CALIFORNIA BUILDING
STANDARDS COMMISSION.
PART 1, CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE
PART 2, CALIFORNIA BUILDING CODE
PART 2.5, CALIFORNIA RESIDENTIAL BUILDING CODE
PART 3, CALIFORNIA ELECTRICAL CODE
PART 4, CALIFORNIA MECHANICAL CODE
PART 5, CALIFORNIA PLUMBING CODE
PART 6, CALIFORNIA ENERGY CODE
PART 8, CALIFORNIA HISTORICAL BUILDING CODE
PART 9, CALIFORNIA FIRE CODE
PART 10, CALIFORNIA EXISTING BUILDING CODE
PART 11, CALIFORNIA GREEN BUILDING STANDARDS CODE
PART 12, CALIFORNIA REFERENCE STANDARDS CODE
2. THE CALIFORNIA ADMINISTRATIVE CODE, TITLE 19 (INDUSTRIAL RELATIONS, PUBLIC SAFETY)
3. THE CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT
4. THE CALIFORNIA ENVIRONMENTAL QUALITY ACT, LATEST EDITION
5. REQUIREMENTS OF THE REGIONAL WATER QUALITY BOARD
6. AIR QUALITY MANAGEMENT DISTRICT REGULATIONS
7. AMERICANS WITH DISABILITIES ACT (ADA), TITLE II, ADAAG (APPENDIX A OF 28CFR PART 36)
8. LOCAL PUBLIC AGENCY STANDARDS.
THE UNIVERSITY IS NOT SUBJECT TO LOCAL JURISDICTIONS' PLANNING/BUILDING CODES, NOR IS IT REQUIRED TO OBTAIN BUILDING PERMITS FROM LOCAL JURISDICTIONS FOR CONSTRUCTION ON REAL ESTATE OWNED OR CONTROLLED BY THE UNIVERSITY. HOWEVER, THE DESIGN AND CONSTRUCTION OF
UTILITY CONNECTIONS AND FIRE-PROTECTION SYSTEMS MAY REQUIRE LIAISON WITH LOCAL
JURISDICTIONS. THIS LIAISON SHALL BE COORDINATED THROUGH THE UNIVERSITY PROJECT
ADMINISTRATOR. CONSTRUCTION OR ENCROACHMENT UPON CITY OR COUNTY OWNED PROPERTY IS
SUBJECT TO LOCAL CODES AND PERMIT REQUIREMENTS.
9. ASHRAE INDOOR AIR QUALITY STANDARD 62-2004.
APPLICABLE CODES
23DSA ACCESS COMPLIANCE NOTES
1. ALL COMMON AREA IMPROVEMENTS INCLUDING RESTROOMS, ENTRY DOORS, ELEVATORS, STAIRS, DRINKING FOUNTAINS ARE UNDER APPROVED DSA #110735.
2. REFER TO FLOOR PLAN (SHEET A1.0) FOR THE FOLLOWING IMPROVEMENTS WITHIN THE TENANT SPACE, LAB 1C1:
A. ACCESSIBLE LAB SINK, SEE SHEET A3.0
B. FIRE EXTINGUISHER, SEE SHEET A3.0
C. LOCATION OF TACTILE EXIT SIGNAGE, SEE SHEET A3.0
D. DOOR SYMBOLS, SEE SHEET A3.0
ONE EXIT REQUIRED, ONE EXIT PROVIDED.
PROJECT MAXIMUM LENGTH TO EXIT = 97 FEET.
ONE EXIT REQUIRED, TWO EXITS PROVIDED.
TWO EXITS REQUIRED, FIVE PROVIDED.
TWO EXITS REQUIRED, FOUR EXITS PROVIDED.
POTENTIAL CUMULATIVE OCCUPANT LOAD FROM SECOND FLOOR TO FIRST FLOOR LOBBY = 86.
POTENTIAL CUMULATIVE OCCUPANT LOAD FROM SECOND FLOOR OCCUPANT TO BRIDGE = 86
POTENTIAL CUMULATIVE OCCUPANT LOAD FROM SECOND FLOOR TO EAST EXTERIOR STAIRS = 57. IF TENANT IMPROVEMENT EXTEND EXIT HALL 202, POTENTIAL CUMULATIVE OCCUPANT LOAD = 86.
POTENTIAL TOTAL CUMULATIVE OCCUPANT LOAD FROM FIRST AND SECOND FLOOR (NOT
INCLUDING FIRST FLOOR EXTERIOR COURTYARD AND COMMON AREAS USED BY BUILDING
OCCUPANTS) = 86 + 102 = 188
ONE HOUR FIRE RESISTANCE RATING NOT REQUIRED PER TABLE 601 IN THESE AREAS.
REQUIRED MINIMUM STAIR WIDTH = 86 x 0.2"/OCCUPANT* = 17.2" (*PER TABLE 1005.1) WIDTH
PROVIDED = 54"
REQUIRED MINIMUM EGRESS COMPONENT WIDTH (WORST CASE WITH FULL OCCUPANT LOAD) =
185 x 0.15"/OCCUPANT = 28" ALLOWABLE OCCUPANT LOAD WITH 36" OPENING = 240 OCCUPANTS, ALL WIDTHS ARE CONFORMING.
TWO EXITS REQUIRED WHEN BREAKROOM AND CONFERENCE ARE COMBINED
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
DSA #110735 FOR ENTIRE BUILDING.
PLATINUM
LAB AREA 1C2
TELECOM
WOMEN'S
MEN'S
LOBBY
1C1-101
OPEN OFFICE AREA 1
1C1-100
PERFORMANCE LOBBY
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
'-6
'-0
1'-4"24'-0"1'-4"4'-11"
31'-7"
6"
D/A2.0
A/A2.0
G/A2.0
F/A2.0
C/A2.0
B/A2.0
E/A2.0
A2.0
A2.0
'-6
21'-2"4'-1"2'-3"3'-0"
'-0
'-2
2' -1
1"
'-3
1' -6
1'
-8
'-6
30'-6"
6 6
4'-2"
3' -9
27 27
A/A2.0
DOOR OR GLAZING PER OPENING SCHEDULE, 14/A3.0
INTERIOR ELEVATION PER 12/A2.0
REFERENCE NOTE PER 14/A1.0
PLATINUM
LAB AREA 1C2
TELECOM
WOMEN'S
MEN'S
LOBBY
1C1-101
OPEN OFFICE AREA 1
1C1-100
PERFORMANCE LOBBY
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
A2.0
A2.0
EXPOSED COMPOSITE STELL/CONCRETE DECK
PERFORATED METAL LINER PANEL ATTACHED TO EXISTING PURLINS
2'x4' SUSPENDED CEILING PANELS TO MATCH EXISTING PANELS IN LOBBY
A
B
C
CEILING TYPES:
30 VARIESB
15'-6"A
9'-0" 9'-0" 15'-6"
10'-0"C
10'-0"C
10'-0"
NOTE: FIRE SPRINKLERS AND EXISTING WATER AND GAS PIPING NOT
SHOWN. VERIFY LOCATION PRIOR TO START OF CONSTRUCTION
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
REFLECTED CEILING PLAN 33
SCALE: 1/4" = 1'-0"
FLOOR PLAN 13
SCALE: 1/4" = 1'-0"
EXISTING 6" METAL STUD WALLS. PROVIDE R-19 BATT INSULATION AND 5/8" TYPE "X" GYPSUM WALL
BOARD.
EXISTING WINDOWS TO REMAIN. WINDOWS ON LINE 7 AND G HAVE OPERABLE VENTS (OVER
LANDSCAPE AREA)
EXISTING METAL BUILDING COLUMN TO REMAIN. EXPOSED SECTIONS OF COLUMNS ARE TO BE
PAINTED.
EXISTING EXPOSED LEAN TO RAFTER. (TO BE PAINTED)
LINE OF SECOND FLOOR ABOVE AND CEILING HEIGHT CHANGE
EXISTING SUN SHADES
LINE OF ROOF OVERHANG
FLOOR GIRDERS ABOVE-EXPOSED GIRDERS TO BE PAINTED.
EXISTING STOREFRONT DOORS, HARDWARE AND SIGNAGE TO REMAIN. APPROVED DSA# 110735
EXISTING SANITARY SEWER LINE IN WALL FOR TI ABOVE / UNUSED. TO BE WASTE CONNECTION FOR
PROPOSED SINK.
EXISTING POLISHED CONCRETE WITH SAWCUT SCORE MARKS.
EXISTING FIRE EXTINGUISHER AND CABINET IN HALL
LAB TABLES AND CABINETS TO BE PROVIDED BY TENANT, INSTALLED BY GENERAL CONTRACTOR.
LAB SINK BY TENANT, LAB SINK IS FOR EMPLOYEES USE ONLY, ACCESSIBILITY IS NOT REQUIRED.
UPPER STORAGE CABINET TO BE PROVIDED BY TENANT INSTALLED BY GENERAL CONTRACTOR.
PROVIDE STRAPPING BEHIND GYPSUM WALL BOARD FOR ATTACHMENT.
4" METAL STUD WALL WITH 5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES AND R-13 FIBERGLASS BATT
INSULATION.
REFERENCE NOTES
FLOOR PLAN &
REFLECTED
CEILING PLAN
A1.0
EXTEND WALL TO 6" ABOVE SUSPENDED CEILING LEVEL.
EXTEND WALL TO BOTTOM OF FLOOR DECK.
TRANSFORMER LOCATION
EXISTING STOREFRONT.
2A10BC FIRE EXTINGUISHER IN RECESSED CABINET, REFER TO SHEET A3.0
WALL MOUNTED FLAT SCREEN TV. TV PROVIDED BY TENANT INSTALLED BY GENERAL CONTRACTOR.
OFFICE SYSTEMS FURNITURE AND DESKS PROVIDE AND INSTALL BY TENANTS.
EXISTING 6" METAL STUD WALLS WITH R19 INSULATION AND 5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES. INTERIOR SIDE OF WALL CURRENTLY HAS LEVEL 2 FINISH AND SHALL BE RE-FINISHED TO MATCH
LEVEL 4.
6" METAL STUD DEMISING WALL CENTERED ON METAL BUILDING FRAME. REFER TO SHEET A3.0
PROVIDE METAL BACKING AND GYPSUM WALL BOARD TO CLOSE GAP AT STEEL COLUMNS TO
WALLS.
EXISTING, FINISHED CONSTRUCTION.
SUSPENDED LINEAR LIGHT FIXTURES PER ELECTRICAL
PENDANT LIGHT FIXTURES PER ELECTRICAL (8) LOCATIONS.
EXPOSED DUCTWORK PER MECHANICAL DRAWINGS
FORCED AIR UNIT SUSPENDED ABOVE CEILING.
ACCESS CEILING PANEL LOCATION.
CEILING HEIGHT CHANGE.
CEILING
EX
PO
SE
D
C O
NS
TR
UC
TIO
N (4
HEIGHTWALL
PAINT
BASEFLOOR WALL
WESTEASTSOUTHNORTH
G
YP
SU
M
W
AL
L B O
AR
D
FA
C
TO
RY
EG
G
SH
EL
L
SE
M
I-G
LO
SS
FL
AT
G
YP
SU
M
W
AL
L B O
AR
D
(1
O
TH
ER
6" C
O
VE
D
4" R
UB
BE
R
TO
P
SE
T B
AS
E
SH
EE
T V
IN
YL
(3
C
AR
PE
T (
2)
VI
NY
L C O
M
PO
SIT
IO
N
TIL
E
C O
NC
RE
TE
, S
EA
LE
D (5
1C1-100
ROOM
NO.
LOBBY
VI
NY
L E
XP
O
SE
D
IN
SU
LA
TIO
N
ROOM NAME
FR
P.
W
AI
NS
C
O T
EX
TR
A
REMARKS
34FINISH SCHEDULE
10'-0"
G
YP
SU
M
W
AL
L B O
AR
D
(1
VI
NY
L E
XP
O
SE
D
IN
SU
LA
TIO
N
FR
P.
W
AI
NS
C
O T
EX
TR
A G
YP
SU
M W
AL
L B
O
AR
D (1
VI
NY
L E
XP
O
SE
D
IN
SU
LA
TIO
N
FR
P.
W
AI
NS
C
O T
FIR
E
RA
TE
D
PL
YW
O
O D
G
YP
SU
M
W
AL
L B O
AR
D
(1
VI
NY
L E
XP
O
SE
D
IN
SU
LA
TIO
N
FR
P.
W
AI
NS
C
O T
EX
TR
A
1. ALL GYPSUM WALL BOARD SHALL HAVE SMOOTH LEVEL 4 FINISH.
2. CARPET PILE HEIGHT SHALL BE 1/2" MAXIMUM. "PATCRAFT" TWEED MODULAR I0096 SERIES, "WELSH" 96300. ROLL CARPET, NO TILES.
3. SHEET VINYL SLIP COEFFICIENT OF FRICTION (SCOF) SHALL BE GREATER THAN 0.6.
4. EXPOSED CEILING, BEAMS, FIRE SPRINKLER LINES, CONDUITS AND DUCTWORK TO BE PAINTED WITH DRY-FALL PAINT.
5. SCORE AND FINISH CONCRETE TO MATCH HALL 102.
6. VERIFY ALL COLORS AND MATERIAL WITH OWNER.
1C1-101 1C1-102 1C1-103
OPEN OFFICE AREA ONE
OPEN OFFICE AREA TWO
LAB
(1)
SU
SP
EN
DE
D T-B
AR
15'-6"±
VARIES
15'-6"±
PE
RF
. M
ET
AL
B
UI
LD
IN
G
LI
NE
R
EAVE HEIGHT
34'-3"
HALL
WOMENS
WOMENS
LAB AREA 2B
LAB AREA 1C
30'-0"
18'-0" 12'-0"
12'-0"
HALL
EAVE HEIGHT
15'-6"
MAINTENANCE
MAINTENANCE
'-0
'-0
'-0
D E F G
A B C
9 9 9 9
22 12
22 12
6 6 6
6 6 6
5' -6
10 11
11 10
1 13
'-7
ROUTE 17
INTERIOR
ELEVATIONS /
SECTIONS
A2.0
EXISTING STEEL BUILDING COLUMNS
EXISTING STEEL BUILDING GIRDER
EXISTING STEEL BUILDING RAFTERS
EXISTING STEEL FLOOR BEAMS
EXISTING SUNSHADES
EXISTING 4" THICK CONCRETE SLAB OVER 2" SAND OVER 10MIL MOISTURE BARRIER OVER 6"
AGGREGATE BASE OVER COMPACTED SUBGRADE.
EXISTING 6" METAL STUDS WITH 5/8" TYPE 'X' GYPSUM WALL BOARD BOTH SIDES. PROVIDE R-19 BATT
INSULATION AT FINISHED WALLS.
PROVIDE R-19 FIBERGLASS BATT INSULATION AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON INTERIOR
WITH LEVEL 5 FINISH.
4" HIGH RUBBER TOP SET BASE, TYPICAL
PENDENT MOUNTED LIGHT FIXTURES PER ELECTRICAL PLANS.
EXPOSED DUCT WORK.
SUSPENDED LINEAR LIGHT FIXTURES.
EXISTING STOREFRONT WINDOWS
EXISTING DRAG BEAM
FIRE EXTINGUISHER IN CABINET. REFER SHEET A3.0
RETURN AIR REGISTERS
EXIT ROUTE SIGN, REFER TO SHEET A3.0
FLATSCREEN TV PROVIDED BY OWNER INSTALLED BY GENERAL CONTRACTOR.
PROPOSED PERFORATED METAL CEILING PANEL.
EXISTING STEEL BUILDING PURLINS AND R-19 INSULATION.
EXISTING COMPLETED CONSTRUCTION.
SUSPENDED CEILING
UPPER CABINETS PROVIDED BY TENANT, INSTALLED BY GENERAL CONTRACTOR
MODULAR INTERIOR WINDOW SYSTEM, REFER TO DOOR SCHEDULE
EXISTING GYPSUM WALL BOARD TO RECEIVE LEVEL 4 FINISH AND PAINT
REFERENCE NOTES
INTERIOR ELEVATIONS 12
SCALE: 3/16" = 1'-0"
SECTION (EXISTING) 24
SCALE: 3/16" = 1'-0"
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
SHEET NUMBER:
DATE: FEBRUARY 28, 2010
SHEET TITLE:
JVA PROJECT NUMBER: M11024
Technology Park
Pilot Project Building
Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
C RPC RPC RPC RP3333
LEASING AGENT:
CALFORNIA CENTRAL COAST
RRRREEEESSSSEEEEAAAARRRRCCCCHHHH PPPPAAAARRRRTTTTNNNNEEEERRRRSSSSHHHHIIIIPPPP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
All designs and other information on these drawings are for use on this specific project and shall not be used otherwise without the expressed written permission of Omni Design Group, Inc.
Written dimensions on these drawings shall take precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on this job and this office shall be notified in writing of any variations from the dimensions or conditions shown in these drawings.
CONSULTANT:
MECHANICAL ENGINEERING
JAMES L VAN DE VANTER, P.E. & ASSOCIATES
1023 NIPOMO STREET, SUITE 200
SAN LUIS OBISPO,CA 93401
(805) 543-3190
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
HVAC ABBREVIATIONS
DESCRIPTION
HVAC LEGEND
SYMBOL DESCRIPTION ABBREV. SYMBOL ABBREV.SYMBOLABBREV. DESCRIPTION
PLUMBING ABBREVIATIONS
DESCRIPTION
PLUMBING LEGEND
SYMBOL DESCRIPTION ABB. SYMBOL SYMBOLABB. DESCRIPTION ABB.
MP1.1
GENERAL NOTES,
ABBREVIATIONS, &
SPECIFICATIONS
SPECIFICATIONSGENERAL NOTES
SHEET NUMBER:
DATE: FEBRUARY 28, 2010
SHEET TITLE:
JVA PROJECT NUMBER: M11024
Technology Park
Pilot Project Building
Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
C RPC RPC RPC RP3333
LEASING AGENT:
CALFORNIA CENTRAL COAST
RRRREEEESSSSEEEEAAAARRRRCCCCHHHH PPPPAAAARRRRTTTTNNNNEEEERRRRSSSSHHHHIIIIPPPP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
All designs and other information on these drawings are for use on this specific project and shall not be used otherwise without the expressed written permission of Omni Design Group, Inc.
Written dimensions on these drawings shall take precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on this job and this office shall be notified in writing of any variations from the dimensions or conditions shown in these drawings.
CONSULTANT:
MECHANICAL ENGINEERING
JAMES L VAN DE VANTER, P.E. & ASSOCIATES
1023 NIPOMO STREET, SUITE 200
SAN LUIS OBISPO,CA 93401
(805) 543-3190
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
MP2.1
SCHEDULES & DETAILS
AFUEBTU/h IN NOTESCFMSYMBOL FAU MODELMFG POWERESP
NOTESWEIGHT
CAPACITYMODELMFGSYMBOL
(LBS.)
SPLIT AC UNIT SCHEDULE
NOTES:
COOLING
COILCAPACITY
MOCP
(AMPS)
MCAPOWERSEER
OUTSIDE
AIR
(CFM)
NAME
PLATE
AMPS
MOCP
(AMPS)
WEIGHT
(LBS.)
INDOOR UNIT
OUTDOOR UNIT
LEGEND
NOTESFINISH OBDBORDERMODELMFG CONST.SYMBOL
SIZE
NECK
NOTES:
AIR TERMINAL SCHEDULE
NOTES
WEIGHT
FULLOPERATING PRESSURE
MODELSYMBOL MANUFACTURER KWPOWER
MIN / MAX
CURRENTINLET &
OUTLET
CAPACITY
(GAL)
FITTINGS
ELECTRIC WATER HEATER SCHEDULE
NOTES:
MIN. 3/4" PLYWOOD BY GC, REFER TO ARCH
1" X 5/16" SHEET METAL SCREW THRU PAN
INTO PLYWOOD - SEAL SCREW HEAD WITH
CAULKINGCEILING STRUCTURE BY GC
2" SCHEDULE 40 PVC FLUE PIPING
2" IPS COPPER MALE ADAPTER SOLDERED
INTO PAN FOR GAS/DRAIN CONNECTION
INTO SUPPORT RAIL FOR SEISMIC
REFRIGERANT LINE INLET AND OUTLET
RESTRAINT
CONDENSATE DRAIN OUTLETS
1" VIBRATION ISOLATOR PAD
FAU & ISOLATOR PAD (PRE-DRILL 1/4") AND
1-1/4" X 5/16" SHEET METAL SCREW THRU
24G GSM PAN (80"X40"x6"), SOLDER
CORNERS AND SEAMS WATERTIGHT
24G GSM SUPPORTS, 'SPOT' SOLDER
BOTTOM OF FAU TO BE MIN. 1" ABOVE
TO BOTTOM OF PAN - TYPICAL
COOLING COIL
SQUARE TO ROUND TRANSITION PER
FORCED AIR UNIT - SEE SCHEDULE
1. EXTEND PLYWOOD DECKING TO ACCESS DOOR FOR MIN. 30" ACCESS TO
FAU, BY GC
2. PROVIDE ELECTRICAL CONVENIENCE OUTLET AT FAU, BY EC
3. PROVIDE ATTIC LIGHT WITH SWITCH ACCESSIBLE FROM LADDER, BY EC
SA RA
SA RA
FRONT VIEW
SIDE VIEW
TOP LIP OF PAN
DECK MOUNTED FAU
NO SCALE14
SMACNA STANDARDS
6 7
16 2" SCHEDULE 40 PVC AIR INLET PIPING
'POINT-OF-USE' WATER HEATER
NO SCALE23
LAVATORY, SEE
SCHEDULE
DOMESTIC COLD WATER
SUPPLY - SEE PLAN FOR
EEMAX®, MODEL SP3512
'POINT-OF-USE' ELECTRIC
INSTANTANEOUS WATER
INLET FILTER
SCREEN
INTEGRAL 3/8" COMPRESSION
COMPRESSION FITTING WITH
INTERNAL FLOW CONTROL,
TYPICAL. DO NOT SOLDER
INLETOUTLET
3/16" x 2" 'SPRING WING'
BACKPLATE MOUNTING
HOLES INTO DRYWALL
SIZING
FULL-FLOW BALL VALVE
BOTH INLET & OUTLET -
SHALL REFER TO MANUFACTURER'S INSTALL
MANUAL FOR ADDITIONAL REQUIREMENTS
PRIOR TO INSTALLING UNIT, CONTRACTOR MANUFACTURER SUPPLIED
FAUCET MOUNTED FLOW
RESTRICTING AERATOR TO
BE INSTALLED
SET INLET VALVE TO
'FULLY OPEN' POSITION &
ADJUST OUTLET VALVE
TO MAINTAIN MAX. 110°F
OUTLET TEMPERATURE
HEATER - SEE SCHEDULE
TOGGLE BOLT THRU
TYPICAL ALL 4 CORNERS
CONDENSATE DRAIN CONNECTION
NO SCALE31
DRAIN PIPING, SEE
TYPE 'L' COPPER CONDENSATE
TAILPIECE W/ CONDENSATE
TO TRAP WATER LEVEL
MAINTAIN MIN. 1" AIR GAP
SWEAT CONNECTION
TRAP WATER LEVEL
PLAN FOR SIZES
FLOOR
WALL
WATER STOP COCK
ADA CLEARANCES
SEE ARCHITECTURAL FOR
DRAWINGS FOR EXTENT
TYPICAL PIPING SUPPORT
NO SCALE
4"
3"
2-1/2"
1"
3/4"
2"
1-1/4"
1-1/2"
10 FT.
10 FT.
10 FT.
6 FT.
6 FT.
6 FT.
10 FT.
6 FT.
4 FT.
4 FT.
4 FT. 10 FT.
10 FT.
10 FT.
4 FT.
4 FT.
4 FT.
4 FT.
4 FT.
8 FT.
10 FT.
8 FT.
10 FT.
10 FT.
SELF TAPPING STEEL
ALL THREAD SCREW
PIPE SHIELD WHEN INSULATION IS REQUIRED
& MORE THAN 12" BELOW SUPPORT STRUCTURE
ONLY REQUIRED IF PIPE IS LARGER THAN 3/4"Ø
SEISMIC BRACING; 1-5/8" ANGLE IRON MAX. LENGTH 6'
BOLT WASHER & NUT THRU
1-5/8" UNISTRUT
UNISTRUT PIPECLAMP - TYPICAL
#10 SM SCREW AT EA. STUD
1/4" X 1-1/2" 'HILTI' HDI DROP IN
ANCHOR W/ 1-1/4" MINIMUM
EMBEDMENT
CMU STRUCTURE
UNISTRUT PIPECLAMP - TYPICAL
1-5/8" UNISTRUT
METAL FRAMING STRUCTURE
IRONDWV/SCH. 40SIZE
MAXIMUM HANGER SPACING
SIZE AND SPACING SCHEDULE
PIPE
COPPER
PLASTIC SCH. 40
1/2" 6 FT. 4 FT. 6 FT.
GAS
NATURAL
WATER, WASTE, AND VENT
1-1/2" 3/8"
2-1/2"
4"
3"
2"
1/2"
1/2"
1/2"
3/8"
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
10 FT.
4 FT.
4 FT.
4 FT.
4 FT.
10 FT.
10 FT.
10 FT.
10 FT.
MIN. HANGER
ROD SIZE
1-1/4"
PIPE
SIZE
3/4"
1/2"
1"
1/4"
1/4"
3/8"
1/4"
CAST IRON
WATER AND WASTE
MAXIMUM HANGER SPACING
STD.
10 FT.
HANGER RODS - SIZE AND SPACING SCHEDULE
COPPER
6 FT.
6 FT.
6 FT.
6 FT.
6 FT.
8 FT.
6 FT.
8 FT.
SCH. 40
STEEL
10 FT.
10 FT.
DWV/SCH. 40
PLASTIC
4 FT.
4 FT.
4 FT.
4 FT.
4 FT.
SCH. 40
6 FT.
8 FT.
10 FT.
10 FT.
8 FT.
GAS
NATURAL
NOTE: LONGITUDINAL BRACINGS AT 8'-0" O.C. MAXIMUM UNLESS OTHERWISE NOTED
INSULATION (IF REQUIRED)
SPLIT RING HANGER(COATED FOR COPPER PIPES)
PIPE SUPPORT SYSTEM SHALL BE INSTALLED PER
SMACNA STANDARDS
PURLIN - TYPICAL
PURLIN - TYPICAL
FLEXIBLE DUCT SUPPORT
NO SCALE24
1- 1 / 2" WIDE x16g G.S.M.
STRAPPING
4'-0" MAX SPACING
1 / 2" MAX ALLOWABLE
SAG PER FOOT OF
SUPPORT BRACING
TO STRUCTURE
1 - 1 / 2" MIN
CONDENSING UNIT ON PLATFORM
NO SCALE41
EVAPORATOR COIL
REFRIGERANT LINES TO
SITE GLASS
REFRIGERATION LINE
SHUT-OFF VALVE-TYP
EXISTING EQUIPMENT PLATFORM
CONDENSING UNIT - SEE SCHEDULE
SECURE CONDENSER
TO PLATFORM WITH 1/2"Ø
LAG BOLTS WITH WASHERS,
MINIMUM 2" EMBEDMENT INTO
BLOCKING (TYPICAL ONE PER
MOUNTING BRACKET)
TRANSFORMER
LAB AREA 1C2
TELECOM
WOMEN'S
MEN'S
LOBBY
1C1-101
OPEN OFFICE AREA 1
1C1-100
PERFORMANCE LOBBY
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
TRANSFORMER
LAB AREA 1C2
TELECOM
WOMEN'S
MEN'S
LOBBY
1C1-101
OPEN OFFICE AREA 1
1C1-100
PERFORMANCE LOBBY
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
SHEET NUMBER:
DATE: FEBRUARY 28, 2010
SHEET TITLE:
JVA PROJECT NUMBER: M11024
Technology Park
Pilot Project Building
Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
C RPC RPC RPC RP3333
LEASING AGENT:
CALFORNIA CENTRAL COAST
RRRREEEESSSSEEEEAAAARRRRCCCCHHHH PPPPAAAARRRRTTTTNNNNEEEERRRRSSSSHHHHIIIIPPPP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
All designs and other information on these drawings are for use on this specific project and shall not be used otherwise without the expressed written permission of Omni Design Group, Inc.
Written dimensions on these drawings shall take precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on this job and this office shall be notified in writing of any variations from the dimensions or conditions shown in these drawings.
CONSULTANT:
MECHANICAL ENGINEERING
JAMES L VAN DE VANTER, P.E. & ASSOCIATES
1023 NIPOMO STREET, SUITE 200
SAN LUIS OBISPO,CA 93401
(805) 543-3190
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
REFERENCE NOTES
1 / 4 " = 1 ' - 0 "
MECHANICAL - FLOOR PLAN
MP3.1
MECHANICAL/PLUMBING
FLOOR PLANS
DOMESTIC WATER SERVICE
GAS SERVICE
FURTHEST DISTANCE
FROM METER
TOTAL
BTU
FUTURE
(MAX)BTU
EXISTING
BTU
NEW
BTU
PIPE
SIZE
UTILITY LINE SIZING
NEW
WSFU
TOTAL
GPM
FLUSH TANK/
FLUSH VALVE
METER
SIZE
PIPE
SIZE
EXISTING
WSFU
FUTURE
WSFU
FRICTION
LOSS
REQ'RD RESIDUAL
PSI AT FURTHEST LENGTH
[D+(Dx0.25)]
TOTAL DEVEL'D ALLOWABLE
AVAILABLE PRESSUREREGULATED
PRESSURE
FIXTURE
SANITARY SEWER
PIPE
SIZE
BUILDING
SLOPE
TOTAL
DFU
EXISTING
DFU
NEW
DFU
TOTAL
CFH
1 / 4 " = 1 ' - 0 "
PLUMBING - FLOOR PLAN
(-ELEV. LOSS)
NOTE
MAKE & MODELSYMBOL DESCRIPTION
ROUGH IN SIZES
FITTINGS OR ACC. NOTES
NOTES:
HW CW W V
PLUMBING FIXTURE SCHEDULE
LAB 1C1
LAB 1C2
LAB 1E
FIRST FLOOR EXTERIOR
COURTYARD
SHOWER
LAB 1B
116HALL
MAINTENANCE
EAST LOBBY
WOMENS
MENS
TELECOM
LOBBY
ENTRY
BREAKROOM
CONFERENCE
LAB 1A
LAB 1D
ELECTRICAL ROOM
NEW CONDENSING
UNITS ON
CONCRETE PADS,
MINIMUM 3' APART,
VERIFY LOCATION
WITH ARCHITECT
CU-1
CU-2
45KVA TRANSFORMER
STRUT MOUNTING FRAME
BRACED TO REAR WALL
100A, 3P FUSED
DISCONNECT SWITCH
CLOSET DOOR
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
1. VISIT JOB SITE AND VERIFY EXISTING CONDITIONS PRIOR TO BID.
2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE
AND ALL APPLICABLE LOCAL ORDINANCES. WHERE PLANS CALL FOR A HIGHER STANDARD THAN
APPLICABLE CODES, THE PLANS SHALL GOVERN.
3. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATIONS SHALL BE DETERMINED IN THE
FIELD TO SUIT FIELD CONDITIONS.
4. ALL ELECTRICAL EQUIPMENT, APPLIANCES AND LIGHTING FIXTURES SHALL BE LISTED BY A RECOGNIZED
TEST AND BEAR THAT LABEL OF APPROVAL.
5. CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT ALL MATERIAL AND EQUIPMENT FOR THIS
WORK UNLESS OTHERWISE NOTED.
6. FURNISH DISCONNECT SWITCHES AT REMOTE MOTORS.
7. ALL SPACES AS INDICATED ON PANELS OR SWITCHBOARDS SHALL BE COMPLETE WITH HARDWARE
AND BUSSING BREAKER FUTURE, BREAKER OR SWITCH.
8. CHECK ARCHITECTURAL PLANS FOR DOOR SWINGS BEFORE INSTALLING SWITCH OUTLETS.
9. GROUNDING AND BONDING SHALL BE PER CODE PLUS ANY ADDITIONAL PROVISIONS SPECIFIED OR
SHOWN ON DRAWING.
10. ALL CONDUIT RUNS SHALL CONTAIN A SIZED GREEN GROUND WIRE.
11. THESE PLANS ARE NOT COMPLETE UNTIL APPROVED BY THE AUTHORITY HAVING JURISDICTION.
12. ALL CONDUCTORS SHALL BE IN EMT CONDUIT, EXCEPT AS NOTED.
13. ALL CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN, 75'° C INSULATION.
14. COORDINATE WITH SERVING ELECTRICAL UTILITY COMPANY AND MAKE PROVISIONS FOR ELECTRICAL SERVICE ACCORDINGLY. INCLUDE ALL SERVICE COSTS AND UTILITY COMPANY CHARGES IN BID.
14ELECTRICAL GENERAL NOTES
REFERENCE NOTES
ELECTRICAL DISTRIBUTION PLAN
EXISTING METERING SECTION, POINT OF CONNECTION FOR ELECTRICAL SERVICE.
PULL BOX, AS REQUIRED.
NEW 4" CONDUIT STUB-OUT INTO LAB 1C1 FROM TELECOM ROOM.
1-1/2" EMT CONDUIT, 3-#2, 1-#8 GND
EXISTING METER SOCKET (1 OF 12). SOCKET LOCATION TO BE DETERMINED BY BUILDING OWNER, METER PROVIDED BY PG&E.
EXISTING MAIN CIRCUIT BREAKER IN "MSB"
SINGLE LINE DIAGRAM & NOTES
ELECTRICAL & TELCOM DISTRIBUTION PLAN 12
SCALE: 1/16" = 1'-0"
ELECTRICAL
DISTRIBUTION PLAN
E1.0PANEL SCHEDULE
SEE PLAN
PANEL: A
120/208V, 3Ø, 4W 125A, 3P
125A RECESSED
SERVICE: MAIN: BUS: MTG: LOC.:
REMARKS
LOAD
ØA ØB ØC
R E C
L T G
I S C
M O L E
P R I P
T I R C
C I R C
C R I P
T O L E
P I S C
ML
T G
R E C
LOAD
ØA ØB ØC
REMARKS
TOTAL = 18,170
TOTAL AMPS = 50.4
ØA = 4,340 ØB = 8,160 ØC = 5,670
A.I.C. RATING = 25K
RECEPTACLES, NORTH
RECEPTACLES, LAB
RECEPTACLES, EAST
720 - -
- -900
- - 720
1 20 1 20 1 20
20 1 20 1
720 - -
- -1080
RECEPTACLES, LOBBY. EMERG. LIGHTS
RECEPTACLES, SOUTH
1200A 277/480V, 3Ø, 4W
M
100A 3P
EXISTING
MAIN SWITCH BOARD IN 1ST
FLOOR ELECTRICAL ROOM
PANEL "MSB"
1 1/2"C 3- #2
1-#8 GND
100A
100A 3P
NEW
ROOM DISCONNECT
SWITCH, 100A, 3P, 600V,
NEMA 1 ENCLOSURE
1 1/2"C 3- #2
1-#8 GND
NEW
45 KVA TRANSFORMER, 480V-120/208V,
3Ø, 4W, NEMA 1 ENCLOSURE
1 1/2"C 4- #1
1-#6 GND
PANEL A NEW
125A LOADCENTER PANEL, 120/208V,
3Ø, 4W, 30 BREAKER SPACE, RECESSED
MOUNT, NEMA 1 ENCLOSURE, 125A, 3P
MAIN CIRCUIT BREAKER, 25K AIC RATED
T-1
RECEPTACLE, CU PAD OUTSIDE
SPACE
SPACE
LIGHTS, OFFICE AREA 1
FORCED AIR UNIT FAU-1
FORCED AIR UNIT FAU-2
500--
750-- 1200 - -
- -1200
20 1
20 1 15 1 15 1
SPACE
SPACE
LIGHTS, AREA 2, LAB
LIGHTING CONTROL PANEL
ELECTRIC WATER HEATER
CONDENSING UNIT CU-1
CONDENSING UNIT CU-2
- - 700 200 - -
- -3480
- - 1500
- -1500
- -1500
- - 1500
1 20 1 15 1 40
#6 AWG
TO NEAREST
BUILDING STEEL
COLUMN
44SWITCH MOUNTING DETAIL-ELEVATION
ROOM DISCONNECT
SCALE: 1" = 1'-0"
A2.0
A2.0
1C1-101
OPEN OFFICE AREA 1
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
A-4
A-5
A-1
PANEL A
A-2
A-3
TRANSFORMER T-1 WITH
ROOM DISCONNECT
SWITCH ABOVE, SEE
DETAIL 44/E1.0
PLATINUM
1C1-100
PERFORMANCE LOBBY
1" EMT CONDUIT FROM
J-BOX TO EACH TELCOM
OUTLET, TYPICAL
NEW 12" X 18" X 6" D
SCREW COVER J-BOX,
OPENING DOWN, 4 PLACES
WH-1
A-15
GFCI
GFCI
GFCI
FAU
15A 1P
SWITCH
A-15 3/4" C
2-#8, 1-#8 GND
A-16
FAU
15A 1P
SWITCH
A-14
NEW 4" EMT
STUB OUT
TELECOM ROOM
COORDINATE HEIGHT
WITH FLAT SCREEN TV COORDINATE HEIGHT WITH
FLAT SCREEN TV
1" EMT CONDUIT FROM
J-BOX TO OUTLET, TYPICAL
A2.0
A2.0
1C1-101
OPEN OFFICE AREA 1
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
PLATINUM
1C1-100
PERFORMANCE LOBBY
S S
S
S S
S S
S S
A-12
A-2
TO
LIGHTING
CONTROL
PANEL
A-11
OR
PANEL A
LIGHTING CONTROL
PANEL
MENS
WOMENS
TELCOM
(2)
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
POWER PLAN 13
SCALE: 1/4" = 1'-0"
LIGHTING & POWER
PLAN
E1.1
LIGHTING PLAN 33
SCALE: 1/4" = 1'-0"
MANUFACTURER & CATALOG NO.TYPE BALLAST
L A M P
MFR TYPE WATTS
LENS REMARKS
14LIGHT FIXTURE SCHEDULE
LINEAR FLUORESCENT, SUSPENDED, 120V, 3-32W
T-8, DIRECT/INDIRECT, 8 FT LONG
PEERLESS 10CRM4-3-32-WHR-PPL-8FT-R8-120-DCT
CABLE SUSPENDED WITH ACG
ADJACENT GRIPPERST-8 (6) 32 (6)
A
B1
B2
C
D
E
LINEAR FLUORESCENT, SUSPENDED, 120V, 2-32W
T-8, DIRECT/INDIRECT 8 FT LONG
PEERLESS 10CRM4-2-32-WHR-PPL-8FT-R8-120-DCT
LINEAR FLUORESCENT, SUSPENDED, 120V, 2-32W
T-8, DIRECT/INDIRECT 4 FT LONG
PEERLESS 10CRM4-2-32-WHR-PPL-4FT-R4-120-DCT
SUSPENDED PENDANT, 12" DIA. ACRYLIC
REFLECTOR, 2-26W CFL, 120V
LIGHTOLIER 40422-404722X-U3
EMERGENCY LIGHT, 90 MIN. BATTERY, ADJUSTABLE
HEADS, 2-5.4W KRYPTON LAMPS, 120V
LITHONIA ELM2-SD
EXIT LIGHT, RED LETTERS, 120V
LITHONIA LESWIRE120/277
T-8 (4) 32 (4)
T-8 (2) 32 (2)
CFL
TT (2) 26 (2)
KRYPTON 5.4 (2)
LED 1.2
ELECTRONIC
DUAL CIRCUIT
ELECTRONIC
DUAL CIRCUIT
ELECTRONIC
DUAL CIRCUIT
ELECTRONIC
PERFORATED STEEL
65% UP, 35% DOWN
PERFORATED STEEL
65% UP, 35% DOWN
PERFORATED STEEL
65% UP, 35% DOWN
ACRYLIC
CABLE SUSPENDED WITH ACG
ADJACENT GRIPPERS
CABLE SUSPENDED WITH ACG
ADJACENT GRIPPERS
SUSPENDED WITH 404-5KG
STRAIGHT CABLE/CORD
WITH SELF-DIAGNOSTICS
A2.0
A2.0
PLATINUM
1C1-101
OPEN OFFICE AREA 1
1C1-100
PERFORMANCE LOBBY
1C1-103
OPEN OFFICE AREA 2
1C1-102
LAB
TO EXISTING FACP IN
ELECTRICAL ROOM
30CD
15CD
15CD
4"
" M
IN
FINISHED
FLOOR
LINE
MANUAL PULL
STATION
AUDIBLE/VISUAL & VISUAL ONLY DEVICES:
WALL MOUNTED APPLIANCES SHALL HAVE THEIR
BOTTOMS AT HEIGHTS ABOVE THE FINISHED
FLOOR OF NOT LESS THAN 80" AND NO GREATER
THAN 96"
6" M
IN
CEILING LINE
AUDIBLE DEVICES: WHERE CEILING HEIGHTS PERMIT
WALL MOUNTED APPLIANCES SHALL HAVE THEIR
TOPS AT HEIGHTS ABOVE FINISHED FLOORS OF NOT
LESS THAN 90" AND BELOW THE FINISHED CEILINGS
OF NOT LESS THAN 6"
CU-1
CU-2
NEW CONDENSING UNITS
ON CONCRETE PADS,
MINIMUM 3' APART.
VERIFY LOCATION WITH
ARCHITECT
LAB 1C2
LAB 1E
EAST LOBBY
TELECOM
GFCI
WP
20A, 2P, 240V WP
DISCONNECT SWITCH,
TYPICAL, 2 PLACES
A-17,19
A-21,23 3" C 2 - #12
1 - #12 GND
TYPICAL, 2 PLACES
A-6
SHEET NUMBER:
DATE: MAY 02, 2011
SHEET TITLE:
PROJECT NUMBER: 1052-01a
Technology Park Pilot Project Building Tenant Improvement
BUILDING 82-C LAB SPACE 1C1
PROJECT:
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
MOUNT BISHOP ROAD
SAN LUIS OBISPO, CALIFORNIA 93407
FACILITIES SERVICES
BUILDING 70
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
ONE GRAND AVENUE
SAN LUIS OBISPO CALIFORNIA 93407
Platinum Performance
67 COMMERCE DRIVE
UNIT 100
BUELLTON, CA 93427
TENANT:
C RP3
LEASING AGENT:
CALFORNIA CENTRAL COAST
RESEARCH PARTNERSHIP
CALIFORNIA POLYTECHNIC STATE UNIVERSITY
SAN LUIS OBISPO, CALIFORNIA 93407
CAMPUS PROJECT MANAGEMENT:
FIRE ALARM & DETECTION PLAN 13
SCALE: 1/4" = 1'-0"
PANEL SCHEDULES &
FIRE DETECTION PLAN
E1.214
DETECTION NOTES
1. ALL FIRE ALARM WIRING TO BE INSTALLED IN CONDUIT.
2. ALL DEVICES TO BE CONNECTED TO THE EXISTING NOTIFIER NFS-2 FIRE ALARM
CONTROL PANEL IN FIRST FLOOR ELECTRICAL ROOM.
3. DEVICES TO BE AS DEFINED IN SYMBOLS TABLE, NO SUBSTITUTIONS OR EQUALS.
GENERAL FIRE ALARM &
24FIRE ALARM SYSTEM SYMBOLS
PHOTOELECTRIC SMOKE DETECTOR (NOTIFIER: FSP-851) WITH DETECTOR BASE
(NOTIFIER 8710LP).
ADDRESSABLE MANUAL PULL STATION (NOTIFIER: NBC-12LX).
VISUAL WHEELOCK: RSS-24MCW
HORN/VISUAL WHEELOCK: RSS-24MCW
44TYP. FIRE ALARM DEVICE MOUNTING ELEVATIONS
SCALE: 1/2" = 1'-0"
C N
INDICATES POWER PANEL LIGHTING CIRCUIT
NUMBERS, TYPICAL.
RELAY CONTACTS INSIDE LIGHTING CONTROL
PANEL, TYPICAL.
LIGHTING CONTROL PANEL, LIGHTING
CONTROL AND DESIGN BLUE BOX LT SERIES,
MODEL GR 1408LT.
LIGHTING OVERRIDE SWITCH, LIGHTING
CONTROL AND DESIGN CHELSEA DIGITAL
SWITCH, SINGLE BUTTON WITH LEGEND "LTG
OVERRIDE."
120V
SPARE
42LIGHTING CONTROL PANEL WIRING & NOTES
SPARE
SPARE
SPARE
SPARE
SPARE
A-13
54CONDENSING UNITS-POWER DETAILS
SCALE: 1/8" = 1'-0"
RJ-45