1305M223QNMAN01727_A0005.pdf

PDF 1 MB Posted

Attached to
Telescoping Crane for the NOAA Ship Nancy Foster
Solicitation number
1305M223QNMAN01727
Issued by

About this file

This document is an amendment to a solicitation for the construction and installation of a telescoping crane for the NOAA Ship Nancy Foster. The National Oceanic and Atmospheric Administration (NOAA) within the Department of Commerce is seeking responses to Solicitation Number 1305M223QNMAN01727 for a telescoping crane that meets ABS standards and the geometric specifications required for the NOAA Ship Nancy Foster. The amendment provides responses to inquiries from interested parties and includes a requested drawing. The response deadline and award timing are not specified. The amendment does not address any pricing terms, set asides, incumbent contractors, or other salient details.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1

1. CONTRACT ID CODE

I

PAGE OF PAGES

I

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER

5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE I

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) SA. AMENDMENT OF SOLICITATION NUMBER

□ SB. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

CODE I FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

D The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers D is extended. D is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning _____ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor D is not D is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item SA or 1 OA, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED

(Signature of person authorized to sign)

Previous edition unusable

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16B. UNITED STATES OF AMERICA 16C. DATE SIGNED

(Signature of Contracting Officer)

STANDARD FORM 30 (REV.11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

…continued from Block 14.

1. Question: Is this intended to be a shipboard crane (lifts in harbor conditions or sheltered waters) or an offshore crane (lifts in higher sea states)?

Answer:

a. For a shipboard crane, the noted capacity and outreach of 6,000 pounds and 42 feet is acceptable, and answers to b, below, are unnecessary.

Answer: This is a shipboard crane.

b. If an offshore crane, depending on the significant wave heights (SWH) and types of lift, ABS requires that the crane be de-rated, so we need the following information:

SWL (loads to be lifted – safe working load)

Offshore: Onboard lifts SWH:

Offshore: Offboard lifts SWH:

Offshore: Subsea lifts, water depth:

Answer: This is not applicable.

2. Question: Operating Temperatures: Minimum/maximum

Answer: Minimum – 0 degrees Fahrenheit

Maximum – 115 degrees Fahrenheit

3. Question: Maximum wind speed anticipated during crane operations

Answer: 20 knots

4. Question: Please confirm that API 2C design is required. If yes, please provide the following information:

Answer: This is a shipboard crane and the following paragraphs do not apply.

a. If it is an Offshore Crane, what is the duty cycle:

Production

Intermediate

Construction

b. Elevation from heel pin to mounting deck and from mounting deck to mean sea level

(MSL):

c. Crane calculation and ratings method:

General method

Vessel-specific method

Legacy dynamic method

5. Question: Is a vessel GA (general arrangement) drawing available? If yes, it will be most helpful to have a copy in order to comply with items 1b and 4 above.

Answer: Drawing is available and is attached to this amendment.

CONTRACT #

NOAA DRAWING NUMBER REVSIZE

SCALE: CAD FILENAME SHT OF

CAGE CODE

DSGN

DWN

CHK

CHK

NOAA APPROVAL

D

C

B

A

C

B

D

A

Seaworthy Systems, Inc.

MARINE ENGINEERS

NAVAL ARCHITECTS TEL: (860) 767-9061

ESSEX, CT 06426

P.O. BOX 965

NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

OFFICE OF MARINE & AVIATION OPERATIONS

NOAA SHIP NANCY FOSTER

BOOKLET OF GENERAL PLANS

50-ABNA-0-00032

TAR-SSI-021-(02)

NF-085-001 CD

AS SHOWN NF085001-1A 1 7

OYLJ5

JEK

12/03/02

DAR

12/03/02

1. THIS BOOKLET OF GENERAL PLANS WAS DEVELOPED UNDER TAR SSI-021(02)

BASED ON A SHIPCHECK CONDUCTED AT CASCADE GENERAL, INC. IN PORTLAND,

OREGON ON OCTOBER 28-30, 2002, FOLLOWING THE DEMILITARIZATION AND

CONVERSION OF THE EX-USNV AGATE PASS (YTT-12) TO A NOAA RESEARCH

VESSEL.

THIS DRAWING SUPERSEDES REFERENCES NO. 1, 2, 3, AND 4.

LIST OF ABBREVIATIONS

BHD

BU

CG

CONT

DC

DF

DO

ENCAP

EM

FC

FCU

FO

FRZR

FS

FW

FXD

GEN

H

LAV

LKR

MSD

NT

PP

REFER

REFRD

SH

SR

SPLY

SWBD

TBL

TK

V

VL

WC

WDO

WT

WTD

XDCR

XFMR

BULKHEAD

BUREAU

CLEANING GEAR

CONTROLLER

DAMAGE CONTROL

DRINKING FOUNTAIN

DIESEL OIL

ENCAPSULATED

EXPANDED METAL

FILE CABINET

FAN COIL UNIT

FUEL OIL

FREEZER

FIRE STATION

FRESH WATER

FIXED

GENERATOR

HATCH

LAVATORY

LOCKER

MARINE SANITATION DEVICE

NON-TIGHT

PUMP

REFRIGERATOR

REFRIGERATED

SHOWER

STATEROOM

SUPPLY

SWITCHBOARD

TABLE

TANK

VENT

VERTICAL LADDER

WATER CLOSET

WINDOW

WATERTIGHT

WATERTIGHT DOOR

TRANSDUCER

TRANSFORMER

COVER SHEET

OUTBOARD PROFILE

INBOARD PROFILE

HOLD LEVEL

MAIN DECK6

SHT TITLE

INDEX

GENERAL DATA

FOC'SLE DECK, 02 LEVEL AND BRIDGE7

DATE APPDDESCRIPTIONITEMZONESHTREV

REVISIONSGENERAL NOTES

2.

YTT 9 CLASS, GENERAL ARRANGEMENTS - DECKS

YTT 9 CLASS, OUTBOARD PROFILE

YTT 9 CLASS, INBOARD PROFILE

YTT 9 CLASS, GENERAL ARRANGEMENTS - HOLD PLAN

801-6500934

801-6500930

5777-005

801-6500933

NO TITLE DRAWING NO

REFERENCES

A 2 10-B 1 ADDED VESSEL CALL LETTERS 1/31/03

RJH

2 10-C 2 MODIFIED VESSEL COMPLEMENT

MODIFIED BRIDGE CONSOLE355-B7

B 3 20-C 1 ADDED 02 HOUSE & 01 DECK EXTENSION 3/11/06

BECI

4 29-C 2

342-C5

6 49-C 4

555-A7

ADDED 02 HOUSE & 01 DECK EXTENSION

MOD STOREROOM 2-7-4-A

ADDED 02 HOUSE & 01 DECK EXTENSION

ADDED 02 HOUSE & 03 DECK EXTENSION

& 01 DECK EXTENSION59-B

60-D

C ALL - 1 GENERAL REVISION AND UPDATE 8/18/06

BECI

SHT OF

SIZE

SCALE:

MARINE ENGINEERS

NAVAL ARCHITECTS

ESSEX, CT 06426

TEL: (860) 767-9061

Seaworthy Systems, Inc.

PREPARED BY:

NOAA DRAWING NUMBERCAGE CODE

CAD FILENAME

REV

A

B

C

D

A

B

C

D

NF-085-001 B

NF085001-2A 2 7

D OYLJ5

AS SHOWN

11 10 9

916 15 14 13 12 11 10

16 15 14 13 12

GENERAL INFORMATION

LAUNCHED

DELIVERED

CONVERTED

CALL LETTERS

BUILDER

HOMEPORT

HULL

SEPTEMBER 1990

JULY 1991

DECEMBER 2002

CASCADE GENERAL INC., PORTLAND, OR

WTER

McDERMOTT SHIPYARDS INC.

AMELIA, LA

CHARLESTON, SC

WELDED STEEL

COMPLEMENT

OFFICERS

CREW

SCIENTISTS

GENERAL CHARACTERISTICS

LENGTH OVERALL

LENGTH BETWEEN PERPENDICULARS

BEAM (MOLDED)

DEPTH TO MAIN DECK (MOLDED)

DESIGN DRAFT

MOLDED DISPLACEMENT (S.W.)

FRAME SPACING

186'-6"

176'-77

16"

40'-0"

16'-0"

10'-6"

1182.37 L.TONS

24"

ENGINEERING

CUMMINS

CUMMINS

ULSTEIN

OMNITHRUSTER

CUMMINS

OUTBOARD MOTOR

NAVIGATION SCIENTIFIC EQUIPMENT

COMMUNICATIONS ACOUSTICS

ELECTRONICS

LAUNCHES & SMALL BOATS

NOTE: ELECTRICAL SERVICE: 450 VAC 3 PHASE, 220 & 120 VAC SINGLE PHASE, 230 VDC, 120 VDC

TYPE PROPULSION LENGTH QTY

TYPE MANUFACTURER PULL/CAPACITY QTY

SATNAV

GMDSS

GYROCOMPASS

RADAR

EPIRB'S

PORTABLE EMERGENCY TRANSCEIVER

EMERGENCY RADIO AUTOALARM

HF TRANSCEIVERS

VHF/FM TRANSCEIVERS

EMERGENCY GENERATOR (450 VAC)

RHIB (AMBAR AM550)

SHIP'S SERVICE GENERATORS (450 VAC)

Z-DRIVE UNIT

MAIN PROPULSION (GEARED DIESEL)

BOW THRUSTER (ELECTRIC)

DOPPLER SPEED LOG

VERTICAL FISH FINDER

MULTIBEAM ECHO SOUNDER (EM1002)

ACOUSTIC DOPPLER CURRENT PROFILER (ADCP)

SHIPBOARD ENVIRONMENTAL

XBT SYSTEM

ACQUISITION SYSTEM (SEAS)

100 KW

395 KW

300 HP

400 HP

1250 BHP/1800 RPM

18.67 FEET 1

DECK MACHINERY

TYPE MANUFACTURER PULL\CAPACITY QTY

AFT CRANE

A-FRAME

J-FRAME

CT WINCH

COM 15 WINCH

APPLETON MARINE

GOODCRANE.COM

ALLIED SYSTEMS

MARKEY

25,000 LBS

10,000 LBS @ 40ft

440 Sq Ft

SEWAGE WASTE CONTROL

OILY WASTE CONTROL

HOLDING CAPACITY

FLOW RATE

MANUFACTURER

SYSTEM TYPE

SYSTEM TYPE

HOLDING CAPACITY

MANUFACTURER

OILY WATER SEPARATOR

VILLAGE MARINE

___GALLONS

__ GPM

OMNIPURE 12MC

CHT WITH MSD

7,500 GALS

DRY LAB

FRESHWATER SYSTEM

TYPE

EVAPORATOR (ALFA-LAVAL)

JWP-16-C40

295 Sq Ft

HABITABILITY

SCIENTIFIC LABORATORY FACILITIES

TOTAL BUNKS ABOARD

MESS

WET LAB

FOUR BUNK ROOMS

DOUBLE STATEROOM

SINGLE STATEROOM

7 CU. METERS/DAYCAPACITY

UNCONTAMINATED SALT WATER SYSTEM

NOAA DRAWING NUMBER REV

CAD FILENAME SHT OFSCALE:

SIZE CAGE CODE

AA

B

C

D D

B

C

NF-085-001 C

NF085001-3C 3 73/16"=12"

D OYLJ5

OUTBOARD PROFILE

SCALE: 3/16" = 1'-0"

1' 2'

6'4' 16'8' 12'

1520 10 5 02530354045505560657075808590 o o o o o o

B L L

B

PROJ

NOAA DRAWING NUMBER REV

CAD FILENAME SHT OFSCALE:

SIZE CAGE CODE

AA

B

C

D D

B

C

NF-085-001 C

NF085001-4A 4 73/16"=12"

D OYLJ5

E X H

.T R U N

K LAUNDRY

CHAIN

LKR EQUIPMENT

FWD HYDRAULIC

AUX. MACHINERY ROOM ENGINE ROOM MULTI-PURPOSE ROOM MSD SEWAGE TANK VOID

THRUSTER SEACHEST

P A S S A G E

W R W C

P A S S A G E

CO SR

BRIDGE

GRATING LEVEL

HOLD DECK

MAIN DECK

FOCSLE DECK

HOLD DECK

CENTERLINE INBOARD PROFILE

WT

BHD BHD

WT

BHD

WT

BHD

WT

BHD

WT

BHD

WT

BULWARK

BULWARK

SCALE: 3/16" = 1'-0"

1' 2'

6'4' 16'8' 12'

MAIN DECK

02 DECK

BRIDGE DECK

03-16-0-C

02-15-0-L

L

02-24-2-L

STAIR

STAIR

01-22-4-L

01-12-0-L

SR (2)

L

L

01-29-2-L

PASSAGESR (4)

01-32-2-L

01-40-2-Q

DC LKR

(GENERALLY LOOKING TO PORT)

1-9-0-Q 1-7-2-Q 1-2-0-E1-12-2-L

SR (4)

1-19-2-L

SR (4)

1-35-2-C

COMPUTER

L

W R W C

L

SR

Q

U P S

R O O M

1-46-2-Q

WORKSHOP

2-46-0-E 1.5-29-2-A 1.5-21-0-W 2-18-0-V 2-12-0-F

TANK

FUEL OIL

BOW THR.

MOTOR COMP.

2-12-0-E

FOREPEAK VOID

2-2-0-V

VOID

2-29-2-V

VOID

2-21-2-V

2-63-0-E

2-83-0-E

STEERING GEAR

PASSAGEWAY

2-79-0-T

POTABLE WATER

2-71-2-W

.5 T

AZIMUTHING THRUSTER P/S

DIRTY OIL TANK

HATCH

HATCH

RUDDER (CL)

JO SR (2)

02-32-2-L

HEAD

02-29-2-L

90 85 80 75 70 65 60 55 50 45 40 3035 25 20 15 10 5 0

BL LB

48x48 HATCH OVER

1.5-36-1-L REFER

1.5-29-0-T

PASSAGE

UP

1.5-29-2-A

MULTI-PURPOSE ROOM

SHELL @ 5'-9" WL

1.5-21-2-L

EXERCISE ROOM

1.5-21-0-W

SEWAGE TANK

1.5-21-1-A

STORES

SHELL @ MAIN DECK

VOID NO. 2 (P)

2-29-2-V(BLW)

CREW'S LOUNGE

FRZ

2-21-2-V(BLW)

VOID NO.1(P)

MSD

2-12-1-F

F.O. TANK NO.3 (S)

VOID NO.2 (S)

2-29-1-V(BLW)

VOID

1.5-18-0-V

FWD

GEAR RM (C)

2-83-0-E

STEERING

POTABLE WTR

TANK (P)

2-71-2-W

FUEL OIL

TANK NO. 2 (S)

2-71-5-F

PASSAGEWAY

2-71-3-T

POTABLE WTR

TANK (S)

2-71-1-W

STOREROOM

2-71-4-A

2-71-6-F

TANK NO. 2 (P)

FUEL OIL

PASSAGEWAY

2-79-0-T

2-83-2-E

STEERING GEAR RM (P)

STEERING GEAR RM (S)

2-83-1-E

C VESSELL

2-80-2-V

VOID

2-80-1-V

VOID

VOID NO. 2 (C)

2-29-0-V(BLW)

SSDG #2

SSDG #3

SSDG #1

MAIN ENGINE

ENGINEERS OPR STA

2-51-2-F

FUEL OIL TK NO.1 (P)

2-46-2-F

FUEL OIL DAY TK (P)

2-48-2-A

2-60-2-A

ENGINEERS STORES

2-57-2-F (UNDER)

LUBE OIL TANK (P)

1.5-57-2-T

ENGINE ROOM EXHAUST TRUNK (P)

FUEL OIL DAY TK (S)

2-46-3-F

FUEL OIL TK NO.1 (S)

2-51-1-F

BILGE MANIFOLD

BILGE PP NO.3

BILGE PP NO.4

L.O. PP, DIRTY OIL PP

A/C UNIT

B

IL

G E

M A N

IF

O L D

2-46-1-C

SWITCHBOARD

ERC

CONSOLE

FIRE PP

POTABLE WTR TK

SPARE

PARTS RM

ELECTRICAL

ROOM

2-48-1-Q

O.W.S.

FUEL OIL TRANSFER MANIFOLD

FUEL OIL PURIFIER

L.P. AIR

COMPRESSORS

OILY BILGE TANK (S)

2-57-1-W (UNDER)

ENGINE ROOM ESCAPE/EXHAUST TRUNK (S)

1.5-57-2-T

A

IR

R C V R

DIRTY OIL TK

SW/JW PLATE

HEAT EXCHANGER

ENGINE ROOM

2-46-0-E

2-2-0-V

FOREPEAK VOID

VOID NO.1(S)

2-21-1-V(BLW)

REFR

COMPRESSORS

F.O. TANK NO.3 (P)

2-12-2-F

2-12-0-E

MOTOR COMPT

BOW THRUSTER

S.W./GNL.

SVC. PUMP

BROMINATOR

J.W.

EVAP

J.W. CIRC

PUMP

EDUCTOR

PUMP

POTABLE WTR

PRESS. SET

FIRE

PUMP

HEAVY LIFT

CAPSTAN HPU

DIVING AIR

COMPRESSOR

SCBA RACK

UP

UP

SPACE HTR

PLAN VIEW, HOLD

SCALE: 3/16" = 1'-0"

SCALE: 3/16" = 1'-0"

1' 2'

6'4' 16'8' 12'

V L

VL

V L

SLIDING

WTD

SLIDING

WTD

Z-DRIVE

UNIT

MOTOR

HPU

BLOWER

HTR

HTR

BLOWER

HPU

MOTOR

UNIT

Z-DRIVE

VL

2-63-0-E

AUXILIARY MACHINERY ROOM

F.S. #8

WTD

WTD

MOON POOL/

DROP TUBE

NOAA DRAWING NUMBER REV

CAD FILENAME SHT OFSCALE:

SIZE CAGE CODE

AA

B

C

D D

B

C

NF-085-001 C

NF085001-5A 5 73/16"=1'

D OYLJ5

DN

90 85 80 75 70 6065 55 50 45 40 35 30 25 20 15 10 5 0

1-19-2-L

MESS AREA

1-18-1-Q

PLAN VIEW, MAIN DECK

SCALE: 3/16" = 1'-0"

GALLEY

1-28-1-Q

1-27-1-A

STORES

1-15-0-L

PASSAGE

WR/WC

1-31-2-L

1-24-2-A

SUPPLY

SR (4)

1-24-4-L

SR (4)

RECIRC. PP

FCSLE DK (OVER)

FWD

1-12-1-Q

SHIP'S OFFICE

1-15-1-E

WTR HTR &

SR (4)

1-12-2-L

1-9-0-Q

LAUNDRY

LC VESSEL

UP

1-9-2-V

VOID

MED LKR

1-9-1-A

1-7-2-A

CHAIN LOCKER

1-7-1-A

CHAIN LOCKER

FWD HYDRAULIC EQUIPMENT RM

1-2-0-E

1-57-1-T

ACCESS

UP

BOAT & DECK

1-58-2-A

GEAR LOCKER

1-43-1-C

WET LAB DRY LAB

1-34-1-C

DN

DN

1-46-4-Q

WORKSHOP

ENGRG OFF

1-43-2-Q

FLUSH HATCH

48x48

1-35-2-C

COMPUTER CTR

HPU

AFT CRANE

PASSAGE

1-61-1

DN

MOON POOL

"J" FRAME

DBL BERTH

DBL BERTH

DBL BERTH

DBL BERTH

DBL BERTH

DBL BERTH

SCALE: 3/16" = 1'-0"

1' 2'

6'4' 16'8' 12'

DOUBLE BITT (P/S)

PANAMA CANAL CHOCK (P/S)

PANAMA

CANAL

CHOCK

(P/S)

TIE-DOWN (TYP.)

STORES

AFFF TANK

SH

SH SH

WC

WC

LKR

LKR

D E S K

D E S K

D E S

KD

E S K

L K R

L K R

LKR

L K R

DESK

DESK

1-20-1-A

SAFE

D E S K

SH

ELV

ES

F.S. #6

F.S. #7

1-46-2-E

NOAA DRAWING NUMBER REV

CAD FILENAME SHT OFSCALE:

SIZE CAGE CODE

AA

B

C

D D

B

C

NF-085-001 C

NF085001-6C 6 73/16"=1'

D OYLJ5

"A" FRAME

W O R K

B E N C H

CABINETS

SCUBA

BOTTLE

RACK

COUNTER D

E S K

LKR ICE

MACHINE

FLASH

FREEZER

CHEST

FREEZER

EQMT

RACK

COUNTER

C O U N T E R

COUNTER

EQMT

RACK

EQMT RACK

DESK FC FC

D E S K

SODA

MACH

90 85 80 75 70 6065 55 50 45 40 35 30 25

15 10 5 0

W

D

W

D

NF085001 March 2010 (1).pdf
Layout1
NF085001-2B.pdf
Layout1
NF085001-3C.pdf
Outboard Profile
NF085001-4C.pdf
INBOARD PROFILE
NF085001-5C.pdf
all
NF085001-6C.pdf
all
NF085001-7C.pdf
all
Check Box1: Off
Check Box2: Off
Check Box3: Off
Check Box4: Yes
Check Box5: Yes
Check Box6: Off
Check Box7: Off
Check Box8: Off
Check Box9: Off
Check Box10: Off
Check Box11: Yes
Text12: A0005
Text13: 12/20/2022
Text14: NM-AN2120-22-01727
Text16: 1
Text17: 10
Text18: AJ930073
Text19: NOAA/ERAD

200 GRANBY STREET

NORFOLK, VA 23510

Jessica Loftus Jessica.Loftus@noaa.gov

Text20: See Block 6
Text21:
Text22: 1305M223QNMAN01727
Text23: 11/14/2022
Text24:
Text25:
Text26: 1
Text27: 1
Text28: Telescoping Crane for the NOAA Ship Nancy Foster

This amendment is being issued to answer inquiries from Interested Parties and to include a requested drawing.