T1.0
AS NOTED
10/10/2017
DR
DR
1 3
FI
R
E A
LA
R
M S
Y S
TE
M
U P
G R
A D
E S
TI
TL
E S
H E
E T
PS
W
R
IV
ER
SI
D
E
FI
R E
LA
B
SHEET OF
DRAWING
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
ST
A
TI
O
N
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
RESEARCH
SOUTHWEST
PACIFIC
DATENO. REVISIONS
STATION
SERVICE
U S D A
PROJECT DRAWINGS FOR:
RIVERSIDE FIRE ALARM SYSTEM UPGRADES
UNITED STATES DEPARTMENT OF AGRICULTURE
FOREST SERVICE
PACIFIC SOUTHWEST RESEARCH STATION
BLDG.
BLDG.
BLDG.
FA1.1
AS NOTED
10/10/2017
DR
DR
2 3
FI
R
E A
LA
R
M S
Y S
TE
M
U P
G R
A D
E S
B U
IL
D
IN
G
F
IR
E
A
LA
R M
S Y
S
TE
M
PS
W
R
IV
ER
SI
D
E
FI
R E
LA
B
SHEET OF
DRAWING
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
A/E
ST
A
TI
O
N
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
RESEARCH
SOUTHWEST
PACIFIC
DATENO. REVISIONS
STATION
SERVICE
U S D A
BUILDING 1 & 2 FLOORPLAN
LEGEND
INSTALL TWO (2) DUCT
SMOKE SENSORS ON AHU-1
SYSTEM (SUPPLY AND RETURN).
AHU-1 LOCATED IN MECH ROOM
BUILDING 1
BUILDING 2
REMOVE EX. BELL
PATCH WALL
EXISTING
TO REMAIN
CONTRACTOR SHALL INSTALL
GRC CONDUIT ON TOP OF
BREEZEWAY ROOF FOR FIRE
ALARM SYSTEM WIRING
BUILDING 2 BASEMENT FLOORPLAN
SEE BUILDING 2 BASEMENT
FLOORPLAN THIS PAGE
INSTALL DUCT SMOKE SENSOR
FOR AHU-2 RETURN SYSTEM.
AHU-2 LOCATED ON ROOF
EX SUPPLY DUCT SMOKE SENSOR
(SYSTEM SENSOR MODEL D4120)
CONNECT EX SENSOR FOR AHU-2 TO
NEW FIRE ALARM SYSTEM. TEST SENSOR
FOR PROPER FUNCTIONALITY W/ BOTH
FIRE AND HVAC SYSTEMS. LOCATED IN
PLENUM SPACE
1":20'
REMOVE EX FIRE
ALARM CONTROL PANEL
FIRE ALARM SYSTEM NOTES - BUILDING 1 & 2 :
THESE REQUIREMENTS SHALL BE USED IN CONJUNCTION WITH THE
PROVIDED CSI SPECIFICATIONS. WHERE THERE IS A CONFLICT BETWEEN
THESE REQUIREMENTS AND THE CSI SPECIFICATIONS, THE MOST STRINGENT
SHALL GOVERN.
1. OCCUPANCY: EXISTING BUSINESS OCCUPANCY. FIRE ALARM SYSTEM IS
"NOT REQUIRED" BY CODE AND IS VOLUNTARILY INSTALLED TO ACHIEVE
SPECIFIC FIRE SAFETY OBJECTIVES. NFPA 72 - 17.5.3.3.1: DETECTION
INSTALLED FOR REASONS OF ACHIEVING SPECIFIC FIRE SAFETY
OBJECTIVES, BUT NOT REQUIRED BY ANY LAWS, CODES, OR STANDARDS,
SHALL MEET ALL OF THE REQUIREMENTS OF THIS CODE WITH THE
EXCEPTION OF THE PRESCRIPTIVE SPACING CRITERIA OF CHAPTER 17.
2. UNLESS OTHERWISE NOTED, DRAWINGS SHOW LOCATIONS OF NEW AND
REPLACEMENT EQUIPMENT TO BE INSTALLED. CONTRACTOR MAY REUSE
EXISTING WIRING AND CONDUIT AS LONG AS IT MEETS THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE
SPECIFICATIONS. EQUIPMENT SHOWN AS EXISTING IS TO REMAIN IN
SERVICE UNLESS OTHERWISE NOTED.
3. FLOORPLAN DRAWINGS ARE INTENDED TO SHOW GENERAL LOCATIONS
OF EQUIPMENT TO BE INSTALLED. FIELD LOCATIONS MAY VARY
DEPENDING ON PROXIMITY TO OTHER FACILITY AND SITE FEATURES.
4. DETECTORS AND NOTIFICATION APPLIANCES SHOWN ON THE DRAWINGS
INDICATE SPECIFIC ROOMS AND CORRIDORS TO BE MONITORED AND
NOTIFIED BY THE FIRE ALARM SYSTEM. DRAWINGS DO NOT INDICATE
SPECIFIC QUANTITIES OR LOCATIONS OF THESE DEVICES. THE
CONTRACTOR SHALL DETERMINE THE APPROPRIATE DEVICE LOCATIONS
AND QUANTITIES FOR THESE SPECIFIC ROOMS AND CORRIDORS PER
MANUFACTURER'S INSTRUCTION, NFPA, ADA, & THE AUTHORITY HAVING
JURISDICTION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND
INSTALLING ALL DEVICES TO MEET THESE REQUIREMENTS. NO DEVICES
ARE REQUIRED IN ROOMS WHERE DEVICES ARE NOT SHOWN ON THE
DRAWINGS. IN CORRIDORS, DETECTORS SHALL BE INSTALLED WITHIN 4
FT OF EXIT DOORS AND 40 FT MAX SPACING WHERE POSSIBLE.
5. CONTRACTOR SHALL REMOVE AND REPLACE NON-ADDRESSABLE PULL
STATIONS WITH NEW ADDRESSABLE PULL STATIONS WHERE EXISTING
PULL STATIONS EXIST. TWO NEW PULL STATION LOCATIONS SHALL BE
INSTALLED: THE KITCHEN OF BLDG 1 AND THE BASEMENT OF BLDG 2.
6. DUCT SMOKE SENSORS SHALL BE INSTALLED FOR THE HVAC SYSTEMS
INDICATED ON THE DRAWINGS AND SHALL BE MONITORED AND ALARMED
BY THE FIRE ALARM SYSTEM. DUCT SMOKE SENSORS SHALL BE
INTEGRATED WITH EXISTING HVAC CONTROL SYSTEMS TO SHUTDOWN
ALL OPERATIONAL CAPACITIES OF THE AIR DISTRIBUTION SYSTEM UPON
ACTIVATION. EXISTING DUCT SMOKE SENSORS ARE INDICATED ON THE
DRAWING AND SHALL BE TESTED FOR PROPER FUNCTIONALITY AND
INTEGRATED WITH THE FIRE ALARM SYSTEM. CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFYING EXISTING HVAC CONTROL SYSTEMS AND
PROPERLY INSTALLING SENSORS IN CODE COMPLIANT LOCATIONS.
SITE PLAN
REMOVE EX FACP
INSTALL NEW FACP
*SCALES ARE ACCURATE WHEN PRINTED AT 11"x17"
EXISTING
REMOVE
CONTRACTOR SHALL INSTALL
GRC CONDUIT UNDER
BREEZEWAY ROOF FOR FIRE
ALARM SYSTEM WIRING
EXISTING HORN
REPLACE W/ HORN STROBE
BLDG.
BLDG.
BLDG.
FA1.2
AS NOTED
10/10/2017
DR
DR
3 3
FI
R
E A
LA
R
M S
Y S
TE
M
U P
G R
A D
E S
B U
IL
D
IN
G
F
IR
E
A
LA
R M
S Y
S
TE
M U
P G
R A
D E
S
PS
W
R
IV
ER
SI
D
E
FI
R E
LA
B
SHEET OF
DRAWING
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
A/E
ST
A
TI
O
N
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
RESEARCH
SOUTHWEST
PACIFIC
DATENO. REVISIONS
STATION
SERVICE
U S D A
BUILDING 3 - 2ND FLOOR
SITE PLAN
LEGEND
BUILDING 3 - 1ST FLOOR
1":25'
1":25'
INSTALL TWO (2) DUCT
SMOKE SENSORS FOR AC-5
SYSTEM (SUPPLY AND RETURN)
EX SUPPLY DUCT SMOKE SENSOR
(SILENT KNIGHT MODEL SD505-ADHR)
TEST SENSOR FOR PROPER
FUNCTIONALITY W/ BOTH
FIRE AND HVAC SYSTEMS
INSTALL TWO (2) DUCT
SMOKE SENSORS FOR AC-6
SYSTEM (SUPPLY AND RETURN)
INSTALL COMPATIBLE ADDRESSABLE
HEAT SENSOR ABOVE EX FACP
EX FACP
(SILENT KNIGHT
5820XL)
EXISTING
TO REMAIN
EXISTING
TO REMAIN
EXISTING
ALL EQUIPMENT IN HATCHED
AREA IS EXISTING AND
SHALL REMAIN IN SERVICE.
EXISTING
TO REMAIN
EXISTING
TO REMAIN
FIRE ALARM SYSTEM NOTES - BUILDING 3 :
THESE REQUIREMENTS SHALL BE USED IN CONJUNCTION WITH THE
PROVIDED CSI SPECIFICATIONS. WHERE THERE IS A CONFLICT BETWEEN
THESE REQUIREMENTS AND THE CSI SPECIFICATIONS, THE MOST STRINGENT
SHALL GOVERN.
1. OCCUPANCY: EXISTING BUSINESS OCCUPANCY. FIRE ALARM SYSTEM IS
"NOT REQUIRED" BY CODE AND IS VOLUNTARILY INSTALLED TO ACHIEVE
SPECIFIC FIRE SAFETY OBJECTIVES. NFPA 72 - 17.5.3.3.1: DETECTION
INSTALLED FOR REASONS OF ACHIEVING SPECIFIC FIRE SAFETY
OBJECTIVES, BUT NOT REQUIRED BY ANY LAWS, CODES, OR STANDARDS,
SHALL MEET ALL OF THE REQUIREMENTS OF THIS CODE WITH THE
EXCEPTION OF THE PRESCRIPTIVE SPACING CRITERIA OF CHAPTER 17.
2. UNLESS OTHERWISE NOTED, DRAWINGS SHOW LOCATIONS OF NEW AND
REPLACEMENT EQUIPMENT TO BE INSTALLED. CONTRACTOR MAY REUSE
EXISTING WIRING AND CONDUIT AS LONG AS IT MEETS THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND THE PROJECT
SPECIFICATIONS. EQUIPMENT SHOWN AS EXISTING IS TO REMAIN IN
SERVICE UNLESS OTHERWISE NOTED.
3. FLOORPLAN DRAWINGS ARE INTENDED TO SHOW GENERAL LOCATIONS
OF EQUIPMENT TO BE INSTALLED. FIELD LOCATIONS MAY VARY
DEPENDING ON PROXIMITY TO OTHER FACILITY AND SITE FEATURES.
4. DETECTORS AND NOTIFICATION APPLIANCES SHOWN ON THE DRAWINGS
INDICATE SPECIFIC ROOMS AND CORRIDORS TO BE MONITORED AND
NOTIFIED BY THE FIRE ALARM SYSTEM. DRAWINGS DO NOT INDICATE
SPECIFIC QUANTITIES OR LOCATIONS OF THESE DEVICES. THE
CONTRACTOR SHALL DETERMINE THE APPROPRIATE DEVICE LOCATIONS
AND QUANTITIES FOR THESE SPECIFIC ROOMS AND CORRIDORS PER
MANUFACTURER'S INSTRUCTION, NFPA, ADA, & THE AUTHORITY HAVING
JURISDICTION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND
INSTALLING ALL DEVICES TO MEET THESE REQUIREMENTS. NO DEVICES
ARE REQUIRED IN ROOMS WHERE DEVICES ARE NOT SHOWN ON THE
DRAWINGS. IN CORRIDORS, DETECTORS SHALL BE INSTALLED WITHIN 4
FT OF EXIT DOORS AND 40 FT MAX SPACING WHERE POSSIBLE.
5. DUCT SMOKE DETECTORS SHALL BE INSTALLED FOR THE HVAC SYSTEMS
INDICATED ON THE DRAWINGS AND SHALL BE MONITORED AND ALARMED
BY THE FIRE ALARM SYSTEM. DUCT SMOKE DETECTORS SHALL BE
INTEGRATED WITH EXISTING HVAC CONTROL SYSTEMS TO SHUTDOWN
ALL OPERATIONAL CAPACITIES OF THE AIR DISTRIBUTION SYSTEM UPON
ACTIVATION. EXISTING DUCT SMOKE DETECTORS ARE INDICATED ON
THE DRAWING AND SHALL BE TESTED FOR PROPER FUNCTIONALITY AND
INTEGRATED WITH THE FIRE ALARM SYSTEM. CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFYING EXISTING HVAC CONTROL SYSTEMS AND
PROPERLY INSTALLING DETECTORS IN CODE COMPLIANT LOCATIONS.
6. ALL NEW AND EXISTING PULL STATIONS SHALL MEET ADA
REQUIREMENTS. WHERE EXISTING PULL STATIONS DO NOT MEET THESE
REQUIREMENTS, THE CONTRACTOR SHALL MODIFY TO BE COMPLIANT.
*SCALES ARE ACCURATE WHEN PRINTED AT 11"x17"
ALL EQUIPMENT IN HATCHED
AREA IS EXISTING AND
SHALL REMAIN IN SERVICE.
EXISTING
TO REMAIN
EXISTING
REMOVE
INSTALL EXISTING EXPOSED
ALARM WIRING IN CONDUIT
(APPROX 3 FT)
SEAL CEILING PENETRATION
INSTALL EXISTING EXPOSED
ALARM WIRING IN CONDUIT
(APPROX 20 FT)
SEAL CEILING PENETRATION
INSTALL EXISTING EXPOSED
ALARM WIRING IN CONDUIT
ALONG WALL (APPROX 40 FT)
SEAL WALL PENETRATION
INSTALL WATERFLOW DETECTOR
ON EXISTING 4" FIRE SPRINKLER
SYSTEM RISER