OSH Tab 06 Asbestos Updated 10 09 2018 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf

PDF 682 KB Posted

Attached to
Columbia Basin Job Corps Center Multi Building HVAC
Solicitation number
1282A720Q0058
Issued by

View the file

Other files

File Type Posted
Revised Drawings Amendment 005 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Amendment 0005 Revised Drawings 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Pre Bid Meeting Notes 04 21 2020 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
OSH Tab 11 Lead Updated 09 12 2017 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Amendment 0004 Misc Attachments 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Amendment 0003 Revised Drawings 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Revised Drawings 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Amendment 0002 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Revised Solicitation 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Amendment 0001 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
SCA Wage Determination No 20155560 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Drawings 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Solicitation 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Statement of Work 1282A720Q0058 Columbia Basin Job Corps Center Multiple Building HVAC Replacement.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COLUMBIA BASIN

JOB CORPS

CIVILIAN

CONSERVATION

CENTER

STANDARD

OPERATING

PROCEDURE

SOP No.

520.6

Date

03/08/19

Revision

CD Approval: K. W. Lester

Safety Officer Approval:

W. Johnston

Supplement To:

PRH 5.20, R6

29 CFR 1910.1001

40 CFR 763

Subject/Title: OSH Plan, Appendix 6: Asbestos Operations and Maintenance Plan

Note: This plan shall be assessed periodically to determine its effectiveness.

Revisions shall be made to modify or improve the procedures as necessary.

A. PURPOSE

Comply with 29 CFR 1910.1001, 40 CFR Part 763, federal, state, and local regulations and Job Corps policy as required by PRH. Chapter 5.16, R5. The program is designed to:

1. Ensure previously released asbestos fibers are cleaned up.

2. Prevent future release by minimizing asbestos containing material (ACM) disturbance or damage.

3. Monitor the condition of ACM.

4. Continue monitoring until all ACM is removed or the building is demolished.

B. STAFFING

The Center’s Maintenance Worker Training Leader shall serve as the Asbestos Program Manager for the Columbia Basin Job Corps CCC.

C. TRAINING

1. The Asbestos Program Manager shall receive initial training including a minimum of 16 hours of both classroom and practical Asbestos O&M training provided by an EPA-accredited training provider and will receive annual asbestos refresher training.

2. Other program participants who are required to monitor the condition and other characteristics of Asbestos Containing Material (ACM) are the Center Safety Officer and the Maintenance staff who shall receive a minimum of 2 hours of asbestos awareness training and will receive annual asbestos refresher training.

3. Asbestos Awareness training for new staff and trainees will be provided by the Safety Officer during staff and trainee orientation training. This training will include the link between smoking, asbestos, and the increased risk of lung cancer. Annual refresher training will be conducted by the Safety Officer during an all center muster.

D. RESPONSIBILITY

The Asbestos Program Manager shall:

1. Record the exact location of ACM on building plans, specifications and drawings.

2. Ensure that when needed ACM is abated prior to undertaking work in those areas.

3. Inform all building occupants, new employees, maintenance staff and custodial workers about the location of the ACM and caution them against disturbing or damaging it, for example by hanging plants from an ACM ceiling.

4. Provide the required general awareness and annual refresher training for maintenance staff, Facilities Maintenance Trade Instructor and Center Safety Officer.

5. Post warning labels near the location of ACM that states “DANGER, ASBESTOS MAY CAUSE CANCER. CAUSES DAMAGE TO LUNGS.

AUTHORIZED PERSONNEL ONLY.”

E. CLEANING AND MAINTENANCE

1. During the initial cleaning of asbestos fibers previously released, licensed asbestos abatement contractors shall steam clean or HEPA vacuum the building carpets; HEPA vacuum all surfaces not able to be wet mopped, such as curtains or books; wet mop all non-carpeted flooring; wipe all horizontal shelves with damp cloths. All filters, mop heads, cloths, and vacuum cleaner bags must be disposed of in sealed plastic bags according to EPA regulations regarding disposal of asbestos wastes.

2. Routine cleaning should be handled in the above manner if debris is found near ACM locations. Debris and/or damage to ACM shall be reported immediately to the Asbestos Program Manager.

3. Maintenance staff and construction trade instructors shall clear all construction, renovation, maintenance, or equipment repair work with the Asbestos Program Manager prior to performing any work. Workers shall avoid patching, repairing or removing any ACM. Under no circumstances are Job Corps trainees or staff to conduct asbestos abatement activities.

F. INSPECTIONS

The Asbestos Program Manager, Center Safety Officer, and/or Environmental Services Contractor shall:

1. Inspect all identified ACM, Appendix A, for damage or deterioration at least twice a year and report and document the findings.

2. Investigate the source of any potential asbestos debris found.

3. Arrange for or conduct sampling on material that is found that is presumed to be asbestos containing material (PACM).

Appendix A

Asbestos Containing Material Inventory

Location (be specific) Warning Posted

(Sign/Sticker) Condition

(Inspection Dates)

1901, Sweet Spot. 9X9 green floor tiles. (Floor tiles are PACM. Samples have been taken to confirm presence of

ACM.)

Sign (sticker) posted at entry doors.

Good condition, no deterioration noted.

No access restrictions.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

2401, boiler room basement, south walls. Wall plastering.

Sign (sticker) posted at entry doors.

Wall is in fair condition, deterioration of the paint noted.

Limited access allowed.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

2401, boiler room basement, boiler base. Insulation around bricks.

Sign (sticker) posted at entry doors.

Bricks and surrounding area are in good condition.

Limited access allowed.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

2402, first floor, east hallway storage room. 9X9 floor tiles.

Sign (sticker) posted at storage room door.

Good condition, no deterioration noted.

No access restrictions.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

2402, first floor, west storage/telephone switch room. 9X9 floor tiles.

Sign (sticker) posted at storage room door.

Good condition, no deterioration noted.

No access restrictions.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

2404, basement, east storeroom. 9X9 floor tiles.

Sign on door. Door locked.

Poor condition, floor broken up. Room is secured and no access is allowed.

Date: 2/17/16

Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19

3604, Carpentry store room.

9X9 green floor tiles. (Floor tiles are PACM. Samples have been taken to confirm presence of ACM.)

Sign (sticker) posted at entry doors.

Good condition, no deterioration noted.

No access restrictions.

Date: 2/17/16 Date: 8/31/16 Date: 5/17/17 Date: 9/20/17 Date: 5/16/18 Date: 9/19/18 Date: 3/08/19