BLDG ID BLDG NAME

Is the property impacted by any other environmental condition which might jeopardize the safety of occupants of the property?

Basis for Determination

Nature of Condition Extent of Condition Location of Condition (quantity) TCLP (Lead‐based paint) Other enivornmental issues?

Basis for

Determination

Black mastic / flooring adhesive Under vinyl sheet flooring in Room 6 (40 sf)

Ceramic tile and grout, 4"x4" Around bathtubs (7 sf)

Roof cement, gray/black Roof penetrations ( 8 sf)

Floor tile and black mastic Under vinyl sheet flooring (242 sf)

Floor tile, 12"x12" and black mastic Throughout house (1100 sf)

Cementitious building board, gray Room 3 water closet (14 sf)

Mortar, for bricks Fireplace (32 sf)

Roof cement, gray/black Roof penetrations (10 sf)

Floor tile and black mastic Under vinyl sheet flooring (270 sf)

Floor tile, 12"x12" and black mastic Room 7 (126 sf)

Floor tile, 12"x12" and black mastic Rooms 1/5/6/7 (620 sf)

Floor tile, 9"x9" Room 3 water closet (9 sf)

Cementitious building board, gray Room 3 water closet / inside door (30 sf)

Roof cement, gray/black Roof penetrations (6 sf)

Regulated Asbestos‐Containing Material

(RACM)

White paint on textured wall board Walls and ceilings (4200 sf)

Category 1 non‐friable asbestos Floor tile, 9"x9" and black mastic Throughout under 12"x12" tile (1760 sf)

RACM White paint on textured wall board Walls and ceilings (6400 sf)

Category 1 non‐friable asbestos Floor tile and black mastic Throughout under 12"x12" tile (1712 sf)

Category 1 non‐friable asbestos Floor tile, 9"x9" and black mastic Unit 1A1 bathroom (40 sf)

RACM White paint on textured wall board Walls and ceilings (6400 sf)

G‐16 CHEV VEHICLE STORAGE NO N/A N/A N/A

RACM White paint texture on wall board Interior walls of building (920 sf)

RACM Sprayed accoustical popcorn ceiling Ceiling throughout 550 sf)

Category 1 non‐friable asbestos Floor tile, 9"x9" and black mastic Rooms 1 through 12 (1728 sf)

Category 1 non‐friable asbestos Floor tile and black mastic Under 12"x12" floor tiling, Rooms 6 and (138 sf)

RACM White paint on textured wall board Walls throughout (6000 sf)

RACM Joint compound on textured wall board Walls throughout (6000 sf)

RACM Sprayed accoustical popcorn ceiling Rooms 1‐5 and 8‐12 (1590 sf)

Category 1 non‐friable asbestos Mortar, for bricks Separation walls between sections (1200 sf)

G‐23 CHEV HELIPORT BUILDING YES RACM Fibrous backing Under vinyl sheet flooring (140 sf)

G‐24 CHEV GENERATOR SHED YES Category 1 non‐friable asbestos Window glazing putty, white Around windows (5 sf)

G‐36 CHEV WASHRACK SHED NO N/A N/A N/A

BUILDING ENVIRONMENTAL STATUS

Results were negative (1.8 mg/L or below) for concentrations of Lead above the EPA concentration of 5.0 mg/L of lead leachate. Base on TCLP factor alone, waste generated from the demolition of these buildings at the site can be characterized as non‐ hazardous waste.

YES

YES

YES

YES

YES

YES

YES

Category 1 non‐friable asbestos

Category 1 non‐friable asbestos

Category 1 non‐friable asbestos

G‐19 CHEV FLAMMABLE STORAGE

G‐11

AMEC Report of Findings, Asbestos/TCLP Survey, dated September 12

CHEV CREW QUARTERS AG‐14

G‐20A / G‐20B / G‐20C

CHEV FIRE OFFICE / SHOP /

STORAGE BLDG

Presence of rodent and other animal droppings in the buildings Field obeservation

CHEV RANGER RESIDENCEG‐12

G‐13 CHEV CREW QUARTERS B

G‐10 CHEV OLD RESIDENCE

CHEV RESIDENCE

File details come from the government source that posted it.