Attachment 2 12805B24R0023 Drawings.pdf
PDF 9 MB Posted
- Attached to
- Construction of a Hay Shelter - Edinburg TX
- Solicitation number
- 12805B24R0023
About this file
This document is a set of drawings and general notes for the construction of a hay shelter at the USDA ARS CFTRU facility in Edinburg, Texas. The key details are:
The solicitation is for the Construction of a Hay Shelter made from shipping containers. The contract will be awarded as a single firm fixed-price purchase order. The requirements are further detailed in the attached Requirements Document. A mandatory site visit must be completed by May 16th, 2024 at 12:00am CT. The agency involved is the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Plains Area. The drawings and general notes cover the site plan, floor plan, elevations, concrete pad details, and electrical requirements including solar lighting options. The drawings also include the basis of design for the pre-engineered metal roof system and solar lighting systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 12805B24R0023 Scope of Work (SOW).pdf | ||
| Sol_12805B24R0023.pdf | ||
| Attachment 3 Davis-Bacon Act WD TX20240255.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING
NUMBER SHEET TITLE
GENERAL DRAWINGS
G-001 COVER SHEET
ARCHITECTURAL
A-002 SITE PLAN
A-100 FLOOR PLAN
A-102 ROOF PLAN
A-001 ARCHITECTURAL GENERAL NOTES
A-200 ELEVATIONS8
A-300 BUILDING SECTION
A-101 CONCRETE PAD DETAILS
A-103 BID OPTION 001 - WALL PANELS
E-001 ELECTRICAL GENERAL NOTES10
E-101 LIGHTING PLAN11
E-102 ROOF PLAN12
E-200 ELEVATIONS13
E-600 SCHEDULES14
ELECTRICAL
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
COVER SHEET
G-001 1 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
6023-M
D. DE LA PAZ
B. DEAN
D. CORDRAY
W. ROSS
U.S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
HAY BARN DESIGN
USDA CFTRL
MOORE FIELD
22675 N MOOREFIELD RD
EDINBURG, TEXAS 78541
LOCATION MAPVICINITY MAP NO SCALE NO SCALE
BASE BID: PROVIDE HAY BARN COMPLETE AND OPERABLE LESS THE END WALL
(BID OPTION 001) AND LESS SOLAR LIGHTING (BID OPTION 002).
BID OPTION 001: PROVIDE “END WALL” FOR ONE END OF HAY BARN TO PROTECT
HAY FROM WIND-DRIVEN RAINS. WALL SHALL BE COMPLETE AND AS INDICATED
ON THE DRAWINGS.
BID OPTION 002: PROVIDE “SOLAR LIGHTING” FOR THE FACILITY INCLUDING
EXTERIOR LIGHTING AT THE OPEN END OF THE HAY BARN AND INTERIOR
LIGHTING WITHIN EACH OF THE TWO SHIPPING CONTAINERS. THE LIGHTING
SYSTEM SHALL INCLUDE SOLAR PANELS AND BATTERY STORAGE AS INDICATED.
THE EXTERIOR AREA LIGHTING SHALL INCLUDE PHOTOCELL FOR EVENING HOURS
ACTIVATION. EACH SHIPPING CONTAINER SHALL BE EQUIPPED WITH AN EXTERIOR
MOUNTED, WEATHER-PROOF WALL SWITCH TO TURN OFF AND ON ALL LIGHT FIXTURES
WITHIN ITS INTERIOR SPACE.
MOORE AIR FIELD
EDINBURG
EL PASO
SAN ANTONIO
LAREDO
CORPUS CHRISTI
GALVESTON
ORANGE
HOUSTON
AUSTIN
DALLASFT WORTH
LUBBOCK
WICHITA FALLS
AMARILLO
DRAWING INDEX
BID OPTIONS:
SITE
MOORE
FIELD
AIRPORT
N.
M
OO
RE
F
IE
LD
R
D.
TX
PROJECT LOCATION
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
Y G. MARTIN
1 3573
A-E CONTRACT NO. 12805B23D0001
A-E TASK ORDER NO. 12805B23F0242
GENERAL NOTES - ARCHITECTURAL:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT
INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL
PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS.
THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT
DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR
IMPLIED THEREFROM.
THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE
WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S
PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS,
ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE
CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW WORK.
ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF
WORK AGREEMENT.
THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL
DISPOSAL OF MATERIALS AND RUBBISH.
ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL
NEW AND EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR
SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS
BEFORE COMMENCEMENT OF WORK.
DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER
SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN
WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
11.
12.
13.
14.
PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT
MANUFACTURER'S STANDARDS.
THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE
CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY
BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC
CORROSION.
DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC
DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE
CONTRACTING OFFICER BEFORE PROCEEDING WITH THE WORK.
THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION
FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A
MANNER TO AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
PLAN NORTH
A101
1i
Room name
A
View Name 1/8" = 1'-0"
R101
A
NORTH
ARROW
SECTION
MARKER
ELEVATION
ROOM TAG
KEY TAG
WALL
TYPE
WINDOW
TYPE
VIEW NAME, NUMBER
AND SCALE
STAIR TAG
DOOR
NUMBER
A101
R ef
R ef
Ref
Ref
EXTERIOR
ELEVATION
INTERIOR
ELEVATION
A101
Ref View Name
R ef Vi ew
N am e
1 Ref View Name
0 GRID
LOCATION
ARCHITECTURAL SYMBOLS:
ANGLE
@ AT
AB ANCHOR BOLT
AC ACOUSTIC
ACC ACCESS
ACT ACOUSTIC CEILING TILE
ACP ACOUSTIC CEILING PANEL
AD AREA DRAIN
ADD ADDITIONAL
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASPH ASPHALT
BB BOND BEAM
BD BOARD
BF BOTH FACES
BFC BELOW FINISH CEILING
BG BUMPER GUARD
BIT BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BLKT BLANKET
BM BEAM/BENCH MARK
BLK BLOCK
BOT BOTTOM
BRG BEARING
BRKR BREAKER
BRK BRICK
BRKT BRACKET
BS BACK SPLASH
BSMT BASEMENT
BTWN BETWEEN
CHANNEL
CAB CABINET
CER CERAMIC
CFCI CONTRACTOR FURNISHED,
CONTRATOR INSTALLED
CG CORNER GUARD
CH COAT HOOK
CIP CAST IN PLACE
CJ CONTROL JOINT/
CONSTRUCTION JOINT
CLG CEILING
CLO CLOSET/CLOSURE
CLR CLEAR
COL COLUMN
COMB COMBINATION
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION/CONNECT
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CPT CARPET
CR COAT RACK/CURTAIN ROD
CSG CASING
CT CERAMIC TILE
CTR CENTER/COUNTER
CTSK COUNTERSUNK
CUH CABINET UNIT HEATER
CW COLD WATER
D DEPTH
DBL DOUBLE
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIR DIRECTION
DIV DIVISION
FA FIELD ADJUSTABLE
FV FIELD VERIFY
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FIN FINISH
FIX FIXTURE
FLEX FLEXIBLE
FLR FLOOR
FLRG FLOORING
FP FIREPROOF/FIRE PROTECTION
FR FIRE RETARDANT
FS FULL SIZE/FULL SCALE
FT FEET
FTG FOOTING
FURG FURRING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GMU GLAZED MASONRY UNIT
GWB GYPSUM WALL BOARD
GYP GYPSUM
H HEIGHT
HDBD HARDBOARD
HDCP HANDICAPPED
HDWD HARDWOOD
HDWE HARDWARE
HK HOOK
HM HOLLOW METAL
HP HIGH POINT
HR HANDRAIL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NONSHRINK
NTS NOT TO SCALE
NWC NORMAL WEIGHT CONCRETE
SOG SLAB ON GRADE
SPEC SPECIFICATION
SPR SPRINKLER
SQ SQUARE
SR SHOWER ROD
SS STAINLESS STEEL
ST STREET
STD STANDARD
STL STEEL
STO STORAGE
STRU STRUCTURAL/STRUCTURE
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMMETRICAL
T & B TOP AND BOTTOM
TB TACKBOARD/TOWEL BAR
TBR TO BE REMOVED
TCP THIN COAT PLASTER
TD TOWEL DISPENSER
TDW TOWEL DISPENSER AND WASTE
TEMP TEMPERATURE/TEMPERED
TER TERRAZZO
TEX TEXTURE
TFC TROWELED FLOOR COVERING
T & G TONGUE AND GROOVE
THK THICK
TOB TOP OF BEAM
TOC TOP OF CURB/TOP OF CONCRETE
TOD TOP OF DECK/TOP OF DUCT ELEVATION
TOF TOP OF FOOTING
TOJ TOP OF JOIST
TOP TOP OF PIPE ELEVATION
TOS TOP OF SLAB/TOP OF STEEL
TOW TOP OF WALL
TPG TOPPING
TPH TOILET PAPER HOLDER
TRAN TRANSOM
TRANS TRANSVERSE
TS TUBE STEEL
TWS THREADED WELDED STUD
TYP TYPICAL
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
UR URINAL
ABBREVIATIONS ABOVE ARE FOR
ARCHITECTURAL SHEETS ONLY.
DM DEMOUNTABLE PARTITION
DN DOWN
DO DITTO
DR DOOR
DRWR DRAWER
DS DOWNSPOUT
DWG DRAWING
DWL DOWEL
DWS DEFORMED WELDED STUD
EA EACH
EC ELECTRICAL CONTRACTOR
EF EACH FACE
EH ELECTRICAL HEATER/EXHAUST HOOD
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR/ELEVATION
EMBED EMBEDDED
EMER EMERGENCY
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ES EMERGENCY SHOWER
ESR ELASTOMERIC SHEET ROOFING
ETR EXISTING TO REMAIN
EVC ELASTIC VINYL COATING
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXC EXCAVATE
EXP EXPANSION
EXPD EXPOSED
EXPF EXPLOSION PROOF
EXT EXTERIOR
HT HEIGHT
HVAC HEATING VENTILATION &
AIR CONDITIONING
HWS HEAD WELDED STUDS
ID INSIDE DIAMETER
IMP INSULATED METAL PANEL
IN INCHES
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
IPW INSULATED PLENUM WALL
IRF INSULATED ROOF FILL
JAN JANITOR
JS JANITOR SINK
JST JOIST
JT JOINT
KD KNOCKED DOWN
KO KNOCK-OUT / KNEE OPENING
L LENGTH
LAB LABORATORY
LAM LAMINATED
LB POUND
LBS POUNDS
LD LINEAR DIFFUSER
LDG LANDING
LF LINEAR FOOT
LG LONG
LGT LIGHT
LKR LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LP LOW POINT
LSH LONG SLOTTED HOLE
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
MACH MACHINE
MAN MANUAL
MAR MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MBW MASONRY BEARING WALL
MC MECHANICAL CONTRACTOR
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MK MARK
ML METAL LATH
MLDG MOLDING
MO MASONRY OPENING
MP METAL PARTITION
MS MACHINE SCREW
MTD MOUNTED
MTG MOUNTING
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
/OVERFLOW DRAIN
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
OZ OUNCE
PART PARTITION
PC PIECE
PCC PRECAST CONCRETE
PCPL PORTLAND CEMENT PLASTER
PDWR PAPER TOWEL DISPENSER &
WASTE RECEPTACLE
PH PHILLIPS HEAD/PHASE
PL PLASTIC LAMINATE
/PLATE/PROPERTY LINE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PM PROTECTED METAL
PNL PANEL
PNLG PANELING
POL POLISHED
PR PAIR
PRE FAB PREFABRICATED
PRE FIN PRE-FINISHED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT/PAINT
PTM PAINT TO MATCH
PVC POLYVINYL CHLORIDE
P.T. PRESSURE TREATED
QT QUARRY TILE
QTY QUANTITY
RAD RADIUS
RAH ROOFTOP AIR
HANDLING UNIT
RB RUBBER BASE
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REINF REINFORCING
REL RELOCATE
REM REMAINDER
REQD REQUIRED
RES RESILIENT
RET RETURN
RI ROUGH IN
RM ROOM
RO ROUGH OPENING
RT RUBBER TILE
RUB RUBBER
SAT STANDARD AGGREGATE
TOPPING
SB SOIL BEARING
SC SEAMLESS COATING
SCF SPECIAL CONCRETE FINISH
SCHD SCHEDULE
SD SOAP DISPENSER
SE SHELF EDGE
SECT SECTION
SF SAND FLOAT
SG SUPPLY AIR GRILLE
SGL SINGLE
SH SHELF
SHD SHOWER DOOR
SHT SHEET
SIM SIMILAR
SJ STEEL JOIST
SLV SHORT LEG VERTICAL
SM SMOOTH
SND SANITARY NAPKIN DISPENSER
SNV SANITARY NAPKIN VENDOR
V VINYL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VOL VOLUME
VWC VINYL WALL COVERING
W WIDE FLANGE STEEL BEAM
W/ WITH
WAF WELDED ANGLE FRAME
WC WATER CLOSET
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
W/O WITHOUT
WP WEATHERPROOF
WPFG WATERPROOFING
WR WASTE RECEPTACLE
WSCT WAINSCOT
WSTP WEATHERSTRIP
WTR WATER
WWF WELDED WIRE FABRIC
ABBREVIATIONS LIST
APPLICABLE CODES AND STANDARDS:
ABBREVIATIONS TITLE EDITION
IBC INTERNATIONAL BUILDING CODE 2021
NFPA 101 LSC LIFE SAFETY CODE 2021
EARTHWORK
GRAVEL
PLASTER,
SAND, GROUT
CONCRETE
CONCRETE
MASONRY
CLAY
MASONRY
PRECAST
CONCRETE
METAL
PLYWOOD
FINISH
LUMBER
WOOD STUDS,
BLOCKING
STEEL STUDS
GYPSUM
WALLBOARD
ACOUSTICAL
TILE
BATT
INSULATION
RIGID
INSULATION
MATERIALS - HATCH SYMBOLS
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
ARCHITECTURAL GENERAL NOTES
A-001 2 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
Y G. MARTIN
1 3573
X
X
X
X X
X
X
X
X
X
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
SITE PLAN
A-002 3 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
KEYED NOTES
1 SHIPPING CONTAINER (SEE A-100)
A. NO EXISTING UTILITIES ARE ANTICIPATED TO BE FOUND IN THE WORK AREA. CONTRACTOR IS RESPONSIBLE FOR PROVIDING UTILITY LOCATE SERVICES TO ENSURE THAT NO UTILITIES WILL BE AFFECTED BY THE WORK. IF UTILITIES ARE FOUND THAT WILL OR COULD BE AFFECTED BY
THE WORK, CONTACT THE CONTRACTING OFFICER IN WRITING BEFORE PROCEEDING WITH
WORK.
B. THE WORK IS LOCATED AT AN ACTIVE AIRFIELD (RUNWAY, TAXIWAY AND AIRCRAFT
FACILITIES). THE CONTRACTOR SHALL COORDINATE ALL WORK ACTIVITIES WITH THE
CONTRACTING OFFICER AND SHALL ABIDE BY ALL GOVERNING AND FEDERAL AVIATION
ADMINISTRATION (FAA) REGULATIONS.
C. AS THE OPERATOR, THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND COMPLY
WITH ALL PROVISIONS OF THE STATE OF TEXAS STORM WATER CONSTRUCTION GENERAL
PERMIT AND ALL LOCAL GROUND DISTURBANCE PERMITTING REQUIREMENTS.
D. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF
EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES, PRIOR TO, OR CONCURRENT
WITH, LAND DISTURBANCE ACTIVITIES.
E. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES.
2 HAY STORAGE AREA (SEE A-100)
3 CRUSHED LIMESTONE PAVING (SEE A-100)
GENERAL WATER POLLUTION PREVENTION NOTES
SCALE: 3/32" = 1'-0"
16' 8' 0 16'
EXISTING FENCE LINE
SOUTHWEST CORNER OF HAY BARN SLAB
EXISTING FENCE LINE
50'
1 2
EXISTING ROAD
EXISTING ROAD
228.5
228.0
227.5
227.0
GENERAL SITE NOTE
S1. THE SITE DRAWING IS BASED ON AERIAL IMAGERY AND IS THEREFORE NOT TO AN EXACT
SCALE.
S2. THE HAY BARN SHALL BE POSITIONED PARALLEL TO AND 50' FROM THE EXISTING FENCE LINES
AS INDICATED. STAKE THE FOUR CORNERS OF THE HAY BARN FOR APPROVAL, PRIOR TO
CONSTRUCTION.
S3. THE TOPOGRAPHIC ELEVATIONS INDICATED ARE BASED ON AERIAL MAPPING AND ONLY
PROVIDED TO GIVE THE GENERAL SLOPE OF THE SITE. THE CONTRACTOR SHALL PROVIDE
GRADING AND LEVELING FOR THE NEW CONSTRUCTION AND AS REQUIRED TO PROVIDE
DRAINAGE AROUND AND AWAY FROM THE HAY BARN CONSTRUCTION.
228.0
SCALE:
SITE PLAN
3/32"=1'-0"
A-002
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
FLOOR PLAN
A-100 4 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
CRUSHED LIMESTONE FROM GRADE TO EDGE
OF CONCRETE SLAB (5 FOOT WIDTH)
8" COMPACTED CRUSHED LIMESTONE PAD
8" REINFORCED CONCRETE PAD
(SEE 1/A-101)
HIGH CUBE (9'-6" HIGH) TYP. SHIPPING
CONTAINER (TYP. OF TWO)
8'X8' MANUAL ROLL-UP DOOR WITH
WEATHERPROOFING (TYP. OF 3 FOR EACH
CONTAINER)
A-300
A-300
8'X40'
SHIPPING
CONTAINER
8'X40'
SHIPPING
CONTAINER
40'X40' HAY STORAGE AREA
5'-0"
6"8'-0"6"39'-0"6"8'-0"6"
5'-0"
5'- 0"
6"
'-0
6" 5'-
0"
DOWNSPOUT WITH CONCRETE SPLASH BLOCK
TYP. OF FOUR
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
A-101
THE BASIS OF DESIGN FOR SHIPPING CONTAINERS IS "40' HIGH CUBE ONE -TRIP CONTAINER" BY CONTAINER KING INC. INCLUDING THEIR 8' ROLL-UP DOOR WITH WEATHER STRIPPING AND CORNER
POST TWIST LOCKS FOR STEEL PLATE WELDING.
BASIS OF DESIGN
SURFACE MOUNTED LED FIXTURES FOR SOLAR
LIGHTING SYSTEM #2 (BID OPTION 002). FOUR
FIXTURES SHOWN FOR BASIS OF DESIGN.
SEE ELECTRICAL.
SURFACE MOUNTED LED FIXTURES FOR SOLAR
LIGHTING SYSTEM #1 (BID OPTION 002). FOUR
FIXTURES SHOWN FOR BASIS OF DESIGN.
SEE ELECTRICAL.
5'-0" TYP.
A-200
A-200
A-200
A-200
SCALE:
FLOOR PLAN
1/4"=1'-0"
A-100
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
T
8"
2"
1 1/2"
CONTROL JOINT DETAIL
'T
1/
'T
1 1/2"
CONSTRUCTION JOINT DETAIL
1/8"
1/
'T
1/8"
1/
'T
SLAB ON GRADE NOTES:
1. CAPILLARY BARRIER SHALL BE A COARSE AGGREGATE WITH #57 GRADATION OR APPROVED
EQUAL.
2. CONCRETE SHALL OBTAIN A MINIMUM 4000 PSI STRENGTH AT 28 DAYS. CONCRETE SLUMP
SHALL NOT EXCEED 5" WITHOUT THE WRITTEN APPROVAL OF THE CONTRACTING OFFICER.
3. AREAS OF THE SITE (WITHIN THE BUILDING AREA) SHOULD BE EXCAVATED TO SUFFICIENT
DEPTHS TO REMOVE EXISTING ORGANIC MATERIAL. THE EXPOSED SUBGRADE
MATERIAL SHOULD BE RE-COMPACTED TO A MINIMUM OF 92% OF THE MAXIMUM DENSITY AS
OF ASTM D1557. A CLEAN, FREE DRAINING GRANULAR MATERIAL SHALL BE INSTALLED
BELOW ALL SLABS ON GRADE. THIS MATERIAL SHALL BE A MINIMUM OF FOUR (4) INCHES AND
COMPACTED TO A MINIMUM 95% OF THE MAXIMUM DENSITY AS DETERMINED BY ASTM D1557.
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
CONCRETE PAD DETAILS
A-101 5 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
1/2" X 12" X 12" STEEL PLATE WITH WELDED
TWIST LOCK ON TOP SIDE AND (4) 5/8" X 6"
WELDED STUDS ON BOTTOM SIDE. EMBED
PLATE IN SLAB (FLUSH) WITH TWIST LOCKS
POSITIONED IN ACCORDANCE WITH SHIPPING
CONTAINER DIMENSIONS (TYPICAL OF 4)
8" REINFORCED CONCRETE SLAB
OUTLINE OF 8' BY 40' SHIPPING CONTAINER
CONCRETE SLAB CONTROL JOINT
(TYPICAL OF 2 PER SLAB)
9'-0"
'-6
'-0
'-6
'-0
EVERY THIRD BAR SHALL
RUN CONTINUOUS
THROUGH THE JOINT
JOINT SEALANT
(1)
JOINT SEALANT
FORMED KEY JOINT ( APPROX 1-1/2" X 3")
EVERY THIRD BAR SHALL
RUN CONTINUOUS
THROUGH THE JOINT
(1) - SAW JOINTS AS SOON AS
CONCRETE SETS AND PRIOR TO
FORMATION OF RANDOM CRACKING
A-101
COMPACTED CRUSHED STONE RAMP
(OVERHEAD DOOR SIDE OF CONTAINERS)
OUTLINE OF SHIPPING CONTAINER
8" REINFORCED CONCRETE SLAB (4,000 PSI CONC.)
3/4" CAMFER ( 4 SIDES OF SLAB)
8" COMPACTED CRUSHED STONE ( WITHIN HAY
STORAGE AREA)
GRADE
4" COMPACTED CRUSHED STONE (CAPILLARY BARRIER)
#4 REINFORCING AT 16' O.C. EACH WAY
6" ALL
FOUR
SIDES
4'
SCALE: 1/2"=1'-0"
0 1' 2' 8'
GRADED/STABLE/ COMPACTED SUBGRADE
(MAY BE UTILIZED IN LIEU OF CONTROL JOINT)
5'-0"
2"
SCALE:
SALB JOINT DETAIL
NTS
A-101
SCALE:
CONCRETE PAD PLAN
1/4"=1'-0"
A-101
SCALE:
CONCRETE PAD SECTION
1/2"=1'-0"
A-101
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
ROOF PLAN
A-102 6 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
CONTINUOUS GUTTER WITH
DOWNSPOUTS
OUTLINE OF SHIPPING
CONTAINER BELOW
METAL ROOF PANELS
METAL RIDGE CAP
A-300
A-300
CONTINUOUS GUTTER WITH
DOWNSPOUTS
OUTLINE OF SHIPPING CONTAINER BELOW
DOWNSPOUT TYP. EACH CORNER
(PROVIDE WITH CONCRETE SPLASH
BLOCK)
THE BASIS OF DESIGN FOR THE PRE-ENGINEERED MEAL ROOFING SYSTEM IS MODEL GB56HZ GABLE PODROOF KIT DESIGNED FOR 182 MPH, EXPOSURE C, RISK CATEGORY 1 INCLUDING GUTTERS AND
DOWNSPOUTS ALL ROOF PANELS, FLASHING, GUTTERS, AND DOWNSPOUTS SHALL HAVE FACTORY
PAINT FINISH. COLOR SHALL BE AS SELECTED BY CONTRACTING OFFICER FROM MANUFACTURES
STANDARD COLOR CHART.
BASIS OF DESIGN OR EQUAL
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002).
SEE ELECTRICAL.
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002).
SEE ELECTRICAL.
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002).
SEE ELECTRICAL.
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"SCALE:
ROOF PLAN
1/4"=1'-0"
A-102
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 001 - WALL PANELS
A-103 7 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
2'- 0"
1'- 0"
COLUMNS (TYP.)
(BID OPTION 001)
METAL WALL PANELS (BID OPTION 001)
METAL ROOF SYSTEM (BASE BID)
SHIPPING CONTAINER (BASE BID - TYP.
OF 2)
7'-3" 8'-0" 8'-0" 8'-0" 7'-3"
A-103
A-103
BID OPTION 001
PROVIDE END CLOSURE WALL
30" CONCRETE FOOTING WITH 4000 PSI
CONCRETE
6"
5'- 0"
1'- 0"
2"X6" HORIZ. AT 24" O.C. (TYP.)
METAL WALL PANEL
COLUMN 6"X6"X 3/16" STEEL TUBE
0 4' 8' 16'
SCALE: 3/16"= 1'-0"
2'
SH
IP
PI
NG
C
ON
TA
IN
ER
SH
IP
PI
NG
C
ON
TA
IN
ER
CONTINUOUS DRIP FLASHING AT
BOTTOM OF PANELS
TOP SHIPPING CONTAINER APPROX.
9'-6" ABOVE SLAB
CONTINUOUS 4"X8"X3/16" STEEL TUBE
WELDED AT ALL POINTS OF CONTACT
TO EACH COLUMN AND TOP OF EACH
SHIPPING CONTAINER
(SEE DETAIL 6/A103)
SCALE: 3/4"=1'-0"
0 1' 2' 4'
#10 X 1/2" SCREW W/ WASHER
(STAINLESS STEEL) AT 12" O.C.
ALUMINUM FLASHING WITH FINISH TO
MATCH WALL PANELS
4"
1" CONT. DRIP WITH CONT. CLEAT
ANCHORED 16" O.C. MAX.
2X6 TREATED CONT. AND SLOPED 6"
BELOW ROOF
2X6 TREATED CONTINUOUS
METAL WALL PANELS
10# X 1" METAL WALL PANEL SCREW
(STAINLESS STEEL) AT MAX 16" O.C.
2"
1" CONTINUOUS DRIP FLASHING
CONTINUOUS
WELDED
CONNECTION
(SEE NOTE)
TOP OF
CONTAINER
4"X8" X 3/16"
STEEL TUBE
NOTE: COORDINATE CONNECTION WITH SHIPPING
CONTAINER AND ROOF MANUFACTURERS. PROVIDE
SHOP DRAWING FOR APPROVAL PRIOR TO WORK.
1"
A-103
A-103
WALL PANEL
STOP TOP OF WALL
6" FROM ROOF
WELD
WELD
A-103
2X6 (TYP.)
12-GA X 2X2 ANGLE 6" LONG
SIMILAR TO SIMPSON STRONG
TIE MODEL ML24Z. WELD TO
COLUMN AND BOLT TO 2X6 WITH
(2) 1/4" X 1 1/2" SCREWS
(TYPICAL)
6"X6"X 3/16"
STEEL TUBE
COLUMN
SCALE:
BID OPTION 001 - PLAN
3/16"=1'-0"
A-103
SCALE:
BID OPTION 001 - NORTH ELEVATION
3/16"=1'-0"
A-103
SCALE:
CONNECTION PLAN
3"=1'-0"
A-103
SCALE:
TOP FLASHING DETAIL
3"=1'-0"
A-103
NOTE: THE END CLOSURE WALL SYSTEM CANNOT BE
ATTACHED TO THE ROOFING SYSTEM UNLESS IT IS AN
ENGINEERED SYSTEM THAT IS PROVIDED BY THE ROOFING
SYSTEM MANUFACTURER. IF THE END WALL IS PROVIDED BY
THE ROOFING MANUFACTURER, THE ROOF AND WALL SHALL
BE A COMBINED PRE-ENGINEERED STRUCTURAL SYSTEM
AND THE WALL DETAILS ON THIS SHEET CAN BE CHANGED
PROVIDED SHOP DRAWINGS AND STRUCTURAL
CALCULATIONS BY A LICENSED STRUCTURAL ENGINEER ARE
SUBMITTED FOR APPROVAL.
NOTE: ALL STEEL SHALL BE GALVANIZED
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
Y G. MARTIN
1 3573
SCALE:
BOTTOM FLASHING DETAIL
3"=1'-0"
A-103
SCALE:
CONNECTION DETAIL
3"=1'-0"
A-103
SCALE:
BID OPTION 001 SECTION
3/4"=1'-0"
A-103
METAL RIDGE CAP
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
ELEVATIONS
A-200 8 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
METAL ROOF SYSTEM. SLOPE AS
REQUIRED TO PROVIDE 12' CLEAR
INSIDE HEIGHT
METAL ROOF SYSTEM. SLOPE AS
REQUIRED TO PROVIDE 12' CLEAR
INSIDE HEIGHT
METAL FRAMING BY ROOF SYSTEM
MANUFACTURER
METAL FRAMING BY ROOF SYSTEM
MANUFACTURER
SHIPPING CONTAINER
GUTTER
DOWNSPOUT
MI
N
'-0
" C
LE
AR
SHIPPING CONTAINER
GUTTER
DOWNSPOUT
METAL RIDGE CAP
METAL ROOF PANELS
GUTTER
DOWNSPOUT
8'X40' CONTAINER
SPLASH BLOCK
8'X8' MANUAL OVERHEAD DOOR (TYP.)
METAL RIDGE CAP
METAL ROOF PANELS
GUTTER
DOWNSPOUT
8'X40' CONTAINER
SPLASH BLOCK
8'X8' MANUAL OVERHEAD DOOR (TYP.)
CONCRETE SPLASH
BLOCK (TYPICAL)
SOLAR PANEL (BID OPTION 002).
SEE ELECTRICAL.
SOLAR PANEL (BID OPTION 002).
SEE ELECTRICAL.
SOLAR PANEL (BID OPTION 002).
SEE ELECTRICAL.
LIGHT SWITCH (BID OPTION 002).
SEE ELECTRICAL.
LIGHT SWITCH (BID OPTION 002).
SEE ELECTRICAL.
AREA LIGHTS (BID OPTION 002).
SEE ELECTRICAL.
SCALE:
NORTH ELEVATION
1/4"=1'-0"
A-200 SCALE:
SOUTH ELEVATION
1/4"=1'-0"
A-200
SCALE:
EAST ELEVATION
1/4"=1'-0"
A-200 SCALE:
WEST ELEVATION
1/4"=1'-0"
A-200
NOTE: NORTH END WALL (BID OPTION 001) NOT SHOWN ON
ELEVATION (SEE 2/A-103 FOR END WALL ELEV.)
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
Y G. MARTIN
1 3573
MI
N
'-0
" C
LE
AR
METAL RIDGE CAP METAL RIDGE CAP
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
Z:
\20
Jo bs \60
-M
U
SD
A Ha y B ar n D es ign
Mo or e F iel d E din bu rg
T X\
W or kin g F old er \F ina l\A rch \A
0.d wg F eb
, 2
4 - 2:
pm
Agricultural
Service Research
USDA CFTRL
MOORE AIR BASE
EDINBURG, TEXAS
HAY BARN DESIGN
BUILDING SECTION
A-300 9 142/29/24
JGM
MRM
JGM 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W.ROSS
40'-0"
56'-0"
57'-0"
8" REINFORCED CONCRETE SLAB
CRUSHED LIMESTONE FROM GRADE TO
EDGE OF CONCRETE SLAB (5 FOOT WIDTH)
8" THICK CRUSHED LIMESTONE PAD
SHIPPING CONTAINER
SCALE: 3/8"=1'-0"
0 1' 2' 4' 8'
NATURAL GRADE
PRE-ENGINEERED METAL ROOF
SYSTEM
(BASIS OF DESIGN: GABLE PODROOF
GB56HZ BY SHIELD ROOF SYSTEMS)
GUTTERS AND DOWNSPOUTS BY METAL
ROOF SYSTEM MANUF. (TYP.)
4" CRUSHED LIMESTONE
9'- 6"
ROOF SLOPE AS REQ'D TO PROVIDE MIN
12' CLEAR HEIGHT
NOTE: VERIFY DIMENSIONS WITH PRE-ENGINEERED
METAL ROOF SYSTEM MANUFACTURER
SCALE:
HAY BARN SECTION
3/8"=1'-0"
A-300
HT
XETA
FO ET
ST
R
EG
IS
SA
TC
E
IT
RERE A CD
JE
RR
Y G. MARTIN
1 3573
METAL RIDGE CAP
MI
N
'-0
" C
LE
AR
GENERAL NOTES - ELECTRICAL:
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO
INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS
SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF WORK SEQUENCING SUCH THAT NO WORK
SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
4. WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, THE REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT
TO THE CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK AGREEMENT.
6. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY DIMENSIONS AND SHALL VERIFY NEW AND EXISTING
CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
7. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DIFFERING
CONDITIONS BEFORE COMMENCEMENT OF WORK.
8. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL
AUTHORITIES HAVING JURISDICTION.
9. PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL
INTEGRITY OF THE BUILDING.
10. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND
PROPERTY AS NECESSARY.
11. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE OWNER'S REPRESENTATIVE PRIOR TO START OF SUCH
WORK.
12. MINIMUM RACEWAY SIZE SHALL BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL
RATIO TO LESS THAN 40% FULL.
13. THE ELECTRICAL CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH OTHER TRADES THROUGH THE GENERAL CONTRACTOR AND SHALL BE RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE AND CORRECT ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS.
14. FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN INSULATED GROUND CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH
BRANCH CIRCUIT. MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND
CONDUCTOR. SINGLE GROUND CONDUCTOR IN ONE RACEWAY MUST BE SIZED FOR THE LARGEST
OVERCURRENT DEVICE.
15. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.
16. ALL CONDUCTORS ARE COPPER.
17. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE
PROCUREMENT OF ANY MATERIALS AND DEVELOPMENT OF ANY SHOP DRAWINGS OR SUBMITTALS.
18. PROVIDE LABELS ON NEW RECEPTACLES, WALL MOUNTED LIGHT SWITCHES/OCCUPANCY SENSORS AND
JUNCTION BOXES INDICATING THE SOURCE PANEL & CIRCUIT(S). TEXT SHALL BE BLACK, 1/4 ” IN HEIGHT
PRINTED ON A CLEAR LABEL. HANDWRITTEN LABELS ARE NOT PERMITTED.
19. NEW EQUIPMENT AND DEVICES ARE TO BE SURFACE MOUNTED UNLESS OTHERWISE NOTED.
PV LIGHTING SYSTEM NOTES:
1. STORAGE LIGHTING SYSTEM REQUIREMENTS (TYPICAL OF 2 SYSTEMS):
1.1. PANELS - REFER TO SPECIFICATION 26 31 00 SECTION 2.1.
1.2. BATTERIES - REFER TO SPECIFICATION 26 31 00 SECTION 2.3.
1.3. CONTROLLER - REFER TO SPECIFICATION 26 31 00 SECTION 2.4.
1.4. LIGHTING FIXTURES - SURFACE MOUNTED LED TYPE, MINIMUM OF 4, REFER TO SPECIFICATION 26 31 00
SECTION 2.2.
1.5. ILLUMINANCE - 15 FC AVG AT FLOOR
1.6. HORIZONTALL ILLUMINANCE RATIO - 3:1 AVG:MIN.
1.7. CONTROL - PROVIDE NEMA 3R SS MANUAL SWITCH AT LOCATIONS IDENTIFIED ON A200. TYPICAL OF 2
LOCATIONS.
1.8. SYSTEM CAPACITY - SIZE PANELS AND BATTERIES TO PROVIDE CAPACITY FOR DUSK ON, DUSK + 6 OFF, 3 DAY CAPACITY.
1.9. BASIS OF DESIGN - SOLAR ELECTRIC POWER CO (SEPCO) SOLARLSQ SYSTEM
2. AREA LIGHTING SYSTEM REQUIREMENTS:
2.1. PANELS - REFER TO SPECIFICATION 26 31 00 SECTION 2.1.
2.2. BATTERIES - REFER TO SPECIFICATION 26 31 00 SECTION 2.3.
2.3. CONTROLLER - REFER TO SPECIFICATION 26 31 00 SECTION 2.4.
2.4. LIGHTING FIXTURES - LED WALL PACK TYPE, MINIMUM OF 2, REFER TO SPECIFICATION 26 31 00
SECTION 2.2.
2.5. ILLUMINANCE - 2 FC AVG AT FLOOR.
2.6. HORIZONTAL ILLUMINANCE RATIO - 3:1 AVG:MIN
2.7. CONTROL - PROVIDE PHOTOCELL CONTROL WITH LOCAL OVERRIDE FOR DUSK ON, DUSK + 6 OFF
CONTROL.
2.8. SYSTEM CAPACITY - SIZE PANELS AND BATTERIES TO PROVIDE CAPACITY FOR DUSK ON, DUSK + 6 OFF, 3 DAY CAPACITY.
2.1. BASIS OF DESIGN - SOLAR ELECTRIC POWER CO (SEPCO) SOLARRWL SYSTEM
3. GRAPHICAL REPRESENTATIONS OF SYSTEM ARE NOT INTENDED TO DEPICT SYSTEM SIZE, PANEL COUNTS, OR FIXTURE COUNTS.
4. CONTRACTOR MUST COORDINATE MOUNTING OF SYSTEM COMPONENTS AND PATHWAYS TO ROOF SYSTEM
WITH ROOF SYSTEM MANUFACTURER. PENETRATIONS OF ROOFING SYSTEM ARE NOT PERMITTED.
PENETRATIONS TO CONTAINER MUST BE LIMITED TO VERTICAL SURFACES UNDER THE COVER OF THE ROOF SYSTEM AND HAVE MINIMUM 3-IN RISE IN CONDUIT PRIOR TO PENETRATION TO FORM A DRIP LOOP. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO EQUIPMENT PROCUREMENT. SUBMITTAL MUST INCLUDE AT A
MINIMUM:
· PANEL MOUNTING DETAIL
· EQUIPMENT MOUNTING DETAIL
· PENETRATION SEALING DETAIL
· IDENTIFICATION OF PANEL/EQUIPMENT MOUNTING POINTS AND CONDUIT ROUTING
REFER TO SPECIFICATION 26 31 00 FOR ADDITIONAL REQUIREMENTS.
5. CONDUIT MUST BE MINIMUM 3/4-IN SCH80 PVC. WHERE SUBJECT TO MECHANICAL DAMAGE, CONDUIT MUST
BE MINIMUM 3/4-IN PVC COATED RMC.
ABBREVIATIONS LIST
A OR AMP AMPERE(S)
ACC AIR COOLED CHILLER
AC ALTERNATING CURRENT
AC AIR COMPRESSOR / AIR
CURTAIN
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING
CAPACITY
AL ALUMINUM
AM AMMETER
ASYM ASYMMETRICAL
AT AMP TRIP
ATS AUTOMATIC TRANSFER
SWITCH
AUTO AUTOMATIC
AWG AMERICAN WIRE GAUGE
B BOILER
BC BRANCH CONTROLLER
BCW BARE COPPER WIRE
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BLDG BUILDING
C CONDUIT
CAT CATEGORY
CB CIRCUIT BREAKER
CCT CORRELATED COLOR
TEMPERATURE
CCTV CLOSED CIRCUIT
TELEVISION
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CH CHILLER
CHWCP CHILLED WATER
CIRCULATING PUMP IN A
PRIMARY-SECONDARY
SYSTEM
CHWP CHILLED WATER PUMP
CHWSP CHILLED WATER SUPPLY
PUMP IN A PRIMARY-
SECONDARY SYSTEM
CKT CIRCUIT
CMH COMMUNICATIONS
MANHOLE
CP CONDENSATE PUMP
CPT CONTROL POWER
TRANSFORMER
CRAC COMPUTER ROOM AC UNIT
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CT COOLING TOWER
CU COPPER OR CONDENSING
UNIT
CWP CONDENSER WATER PUMP
D DEPTH
DC DIRECT CURRENT
DF DESTRATIFICATION FAN
DH or DUH DUCT HEATERS
DHWCP DOMESTIC HOT WATER
CIRCULATING PUMP
DISC DISCONNECT SWITCH
DOAS DEDICATED OUTSIDE AIR
SYSTEM (UNIT)
DPST DOUBLE POLE SINGLE
THROW
DPDT DOUBLE POLE DOUBLE
THROW
DSCU DUCTLESS SPLIT
CONDENSING UNIT
(POWERS THE DSS INDOOR
UNIT)
DSHP DUCTLESS SPLIT HEAT
PUMP (POWERS THE DSS
INDOOR UNIT)
DSS DUCTLESS SPLIT SYSTEM
(INDOOR UNIT)
DWBP DOMESTIC WATER
BOOSTER PUMP
DX DIRECT EXPANSION (DX)
COOLING COIL
EC EMPTY CONDUIT
EF EXHAUST FAN
ELEC ELECTRICAL
EMH ELECTRICAL MANHOLE
EMT ELECTRICAL METALLIC
TUBING
E or EMER EMERGENCY
EPA EFFECTIVE PROJECTED
AREA
EQUIP EQUIPMENT
ERV ENERGY RECOVERY
VENTILATOR
ERU ENERGY RECOVERY UNIT
EXIST or EX EXISTING
NOTE: ABBREVIATIONS ABOVE
ARE FOR ELECTRICAL SHEETS
ONLY. NOT ALL ABBREVIATIONS
SHOWN WILL BE USED ON THIS
PROJECT.
EUH ELECTRIC UNIT HEATER
EXP EXPLOSION PROOF
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
F FUSE
FACP FIRE ALARM CONTROL
PANEL
FCU FAN COIL UNIT
FLEX FLEXIBLE
FWE FURNISHED WITH
EQUIPMENT
G OR GND GROUND
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFI GROUND FAULT
INTERRUPTER
GRS GALVANIZED RIGID STEEL
CONDUIT
GUH GAS UNIT HEATER
GWH GAS WATER HEATER
H or HT HEIGHT
HAC HEATED AIR CURTAIN
HOA HAND-OFF AUTOMATIC
HP HORSE POWER
HP HEAT PUMP (OUTDOOR
PORTION OF SPLIT SYSTEM
HEAT PUMP, USE CU FOR
STANDARD DX OUTDOOR
UNIT)
HT HEAT TRACKING
HVU HEATING/VENTILATING UNIT
HWCP HEATING WATER
CIRCULATING PUMP IN A
PRIMARY-SECONDARY
SYSTEM
HWP HEATING WATER SUPPLY IN
A PRIMARY-ONLY SYSTEM
HWRP HOT WATER
RECIRCULATION PUMP
HWSP HEATING WATER SUPPLY
PUMP IN A PRIMARY-
SECONDARY SYSTEM
HWUH HOT WATER UNIT HEATER
HZ HERTZ
IDS INTRUSION DETECTION
SYSTEM
IMC INTERMEDIATE METAL
CONDUIT
IRH INFRARED HEATER
J OR JB JUNCTION BOX
K KILO
KAIC THOUSAND AMPERE
INTERRUPTING CAPACITY
KCM OR KCMIL THOUSAND OF CIRCULAR
MILS
KEF KITCHEN EXHAUST FAN
KH KITCHEN HOOD
KV KILOVOLT
KVA KILOVOLT-AMPERES
KW KILOWATT
KWHR KILOWATT-HOUR
L LENGTH
LA LIGHTNING ARRESTOR
LAN LOCAL AREA NETWORK
LAV LAVATORY
LM LOCKHEED MARTIN
LTG LIGHTING
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MCB or MB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MGB MAIN GROUND BAR
MH MANHOLE or MOUNTING
HEIGHT
MIN MINIMUM
MLO MAIN LUGS ONLY
MOD MOTOR OPERATED DAMPER
MT or MTD MOUNT or MOUNTED
MRS MOTOR RATED SWITCH
N NEUTRAL
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NC NORMALLY CLOSED
NESC NATIONAL ELECTRICAL
SAFETY CODE
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
P POLE(S) or PUMP
PA PUBLIC ADDRESS
PDU POWER DISTRIBUTION UNIT
PF POWER FACTOR
PH PHASE
PIU VAV TERMINAL UNIT WITH
PARALLEL OR SERIES FAN
(PRIMARY INDUCTION UNIT)
PMT PAD MOUNTED
TRANSFORMER
PNL PANEL OR PANELBOARD
PTAC PACKAGED THRU-WALL AIR
CONDITIONER
PVC POLYVINYL CHLORIDE
RECEPT or RECP RECEPTACLE
RF RETURN FAN
RH RADIANT HEATERS
(ELECTRIC)
RMC RIGID METAL CONDUIT
RMS ROOT MEAN SQUARE
RTU ROOF TOP UNIT
RVNR REDUCED VOLTAGE NON-
REVERSING
SA SURGE ARRESTOR
SCCR SHORT CIRCUIT CURRENT
RATING
SD SMOKE DAMPER
SF SUPPLY FAN
S/N SOLID NEUTRAL
SP SUMP PUMP
SPD SURGE PROTECTIVE DEVICE
SPDT SINGLE POLE DOUBLE
THROW
SPEC SPECIFICATIONS
SPST SINGLE POLE SINGLE
THROW
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TMGB TELECOMMUNICATIONS
MAIN GROUNDING BUSBAR
TOL THERMAL OVERLOAD
TP TWISTED PAIR
TYP TYPICAL
U URINAL
UH UNIT HEATER
UG UNDERGROUND
UIO UNLESS INDICATED
OTHERWISE
UL UNDERWRITERS
LABORATORY
UTP UNSHIELDED TWISTED PAIR
V VOLTS
VA VOLT AMPERES
VAV VAV TERMINAL UNIT
VEF VEHICLE EXHAUST FAN
VM VOLTMETER
VRF VARIABLE REFRIGERANT
FLOW SYSTEM
W WATTS or WIRE or WIDTH
WC WATER CLOSET
WEF WELDING EXHAUST FAN
WH WATER HEATER
WHDM WATTHOUR DEMAND METER
WSHP WATER SOURCE HEAT
PUMP
WP WEATHERPROOF
XFMR TRANSFORMER
Z IMPEDANCE
APPLICABLE CODES AND STANDARDS:
ABBREVIATIONS TITLE EDITION
NFPA 1 FIRE CODE 2024
NFPA 70 (NEC) NATIONAL ELECTRICAL CODE 2023
NFPA 70B RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE2023
NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE 2024
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
C:
\U se rs\ tjo hn so n.J
MC
FI
RM
\A pp Da ta\ Lo ca l\T em p\A cP ub lis h_
\E
1.d wg
F eb
, 2
4 -
8:
am
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 002
ELECTRICAL GENERAL NOTES
E-001 10 1402/29/24
JGM
BSN
DRL 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
SYMBOL / KEY
LIGHT FIXTURE, RECESSED, PENDANT
OR SURFACE MTD.
DESCRIPTION SYMBOL / KEY DESCRIPTION
UPPERCASE LETTER INDICATES
LUMINAIRE / SWITCH TYPE, LOWERCASE
LETTER INDICATES CONTROL GROUP.S A,aA,a
SM
MANUAL SWITCH
LIGHTING AND SWITCHING LEGEND
LIGHT FIXTURE, WALL PACK SP
PHOTOCELL
SYMBOL / KEY
REVISION TAG DESIGNATION
DESCRIPTION
KEY NOTE DESIGNATION
NOTE: ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 WIRE #12AWG CIRCUIT WITH A #12AWG
GND. A GREATER NUMBER OF WIRES IS INDICATED AS FOLLOWS:
4 WIRE, 2 CIRCUITS & GROUND (LONGER SLASH INDICATES NEUTRAL)
6 WIRE, 3 CIRCUITS & GROUND, ETC.(WIRING LARGER THAN #12AWG SHALL BE AS NOTED)
INDICATES #12 GROUND CONDUCTOR UOI (DOUBLE TICK/SLASH INDICATES ISOLATED GROUND)
PANELBOARD AND CIRCUIT DESIGNATION
RACEWAY CONCEALED IN WALL OR CEILING OR EXPOSED ON STRUCTURE AS REQUIRED
HOMERUN TO PANELBOARD - LETTERS INDICATE PANEL, NUMBERS INDICATE CIRCUIT
RACEWAY CONCEALED UNDER FLOOR OR BELOW GRADE. UNDER SLAB APPLICATIONS: RUN BELOW GRAVEL
(NOT ALL SYMBOLS MAY APPLY, TYP.)
NEW WORK LINE WEIGHT
LA1:13
LA1:13
GENERAL SYMBOLS LEGEND
THE BASIS OF DESIGN FOR SOLAR POWERED LIGHTING SYSTEMS #1 AND #2 IS A STANDALONE SOLAR
POWERED LIGHTING SYSTEM INCLUDING PANELS, CONTROLLER, BATTERY, AND FOUR SURFACE
MOUNTED FIXTURES BY SOLAR ELECTRIC POWER CO (SEPCO). SYSTEM SHALL ILLUMINATE
CONTAINER FLOOR TO 15 FC AVG WITH A HORIZONTAL ILLUMINANCE RATIO LESS THAN OR EQUAL TO
3:1 AVG:MIN. EACH SYSTEM SHALL INCLUDE A MANUAL SWITCH ON THE CONTAINER CENTERED
BETWEEN THE MIDDLE AND SOUTH DOORS, TYPICAL FOR EACH SYSTEM. SYSTEM BATTERIES SHALL BE
SIZED BASED ON DUSK ON, DUSK+6 OFF, 3 DAY CAPACITY.
THE BASIS OF DESIGN FOR SOLAR POWERED LIGHTING SYSTEM #3 IS A STANDALONE SOLAR
POWERED LIGHTING SYSTEM INCLUDING PANELS, CONTROLLER, BATTERY, AND TWO WALL MOUNTED AREA FIXTURES BY SOLAR ELECTRIC POWER CO (SEPCO). SYSTEM SHALL ILLUMINATE GROUND LEVEL TO 2 FC AVG WITH A HORIZONTAL ILLUMINANCE UNIFORMITY LESS THAN OR EQUAL TO 3:1 AVG:MIN FOR THE AREA EXTENDING OUT 5-FT FROM THE SOUTH FACE OF THE BARN (BETWEEN CONTAINERS APPROX 5' X 40'). CONTRACTOR SHALL PROVIDE UNI-STRUT OR OTHER SUPPORTING MEANS TO MOUNT LIGHTS 12-FT AFG BASED ON THE STRUCTURE SELECTED. SYSTEM SHALL BE DUSK ON, DUSK + 6 HRS OFF. SYSTEM BATTERIES SHALL BE SIZED BASED ON DUSK ON, DUSK+6 OFF, 3 DAY CAPACITY.
SOLAR LIGHTING BASIS OF DESIGN (BID OPTION 002)
SCALE: 3/8"=1'-0"
0 1' 2' 4' 8'
PPM
REVISIONS
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
C:
\U se rs\ tjo hn so n.J
MC
FI
RM
\A pp Da ta\ Lo ca l\T em p\A cP ub lis h_
\E
1.d wg
F eb
, 2
4 -
8:
am
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 002
LIGHTING PLAN
E-101 11 1402/29/24
JGM
BSN
DRL 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
OUTLINE OF SHIPPING
CONTAINER
SCALE:
LIGHTING PLAN
3/8" = 1'-0"E-101
OUTLINE OF SHIPPING CONTAINER
SM,a
S M, b
A,a
A,a
A,a
A,a A,b
A,b
A,b
A,b
W,c W,c SM,cSP,c
SYSTEM 1 CONTROLLER
SYSTEM 2 CONTROLLER
SYSTEM 3 CONTROLLER
LIGHTING FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002)
LIGHTING FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002)
LIGHTING FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002)
E-200
E-200
E-200
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
C:
\U se rs\ tjo hn so n.J
MC
FI
RM
\A pp Da ta\ Lo ca l\T em p\A cP ub lis h_
\E
2.d wg
F eb
, 2
4 -
8:
am
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 002
ROOF PLAN
E-102 12 1402/29/24
JGM
BSN
DRL 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
OUTLINE OF SHIPPING
CONTAINER BELOW
SCALE:
ROOF PLAN
3/8" = 1'-0"E-102
OUTLINE OF SHIPPING CONTAINER
BELOW
THE BASIS OF DESIGN FOR THE PRE-ENGINEERED MEAL ROOFING SYSTEM IS MODEL GB56HZ GABLE PODROOF KIT DESIGNED FOR 182 MPH, EXPOSURE C, RISK CATEGORY 1 INCLUDING GUTTERS AND
DOWNSPOUTS ALL ROOF PANELS, FLASHING, GUTTERS, AND DOWNSPOUTS WITH FACTORY PAINT
FINISH.
BASIS OF DESIGN
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002)
SCALE: 3/8"=1'-0"
0 1' 2' 4' 8'
SYSTEM 1 CONTROLLER SYSTEM 2 CONTROLLER
SYSTEM 3 CONTROLLER
E-200
E-200
E-200
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
C:
\U se rs\ tjo hn so n.J
MC
FI
RM
\A pp Da ta\ Lo ca l\T em p\A cP ub lis h_
\E
0.d wg
F eb
, 2
4 -
8:
am
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 002
ELEVATIONS
E-200 13 1402/29/24
JGM
BSN
DRL 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
SCALE:
EAST ELEVATION
1/4" = 1'-0"E-200
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
SCALE:
WEST ELEVATION
1/4" = 1'-0"
E-200
SCALE:
SOUTH ELEVATION
1/4" = 1'-0"E-200
SHIPPING CONTAINER
MI
N
'-0
" C
LE
AR
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002)
LIGHT SWITCH FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002). MOUNT
48-IN AFG.
LIGHT SWITCH FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002). MOUNT
48-IN AFG.
AREA LIGHTS FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #1 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #2 (BID OPTION 002)
SOLAR PANEL FOR SOLAR LIGHTING
SYSTEM #3 (BID OPTION 002)
PROVIDE PHOTOCELL FOR SOLAR
LIGHTING SYSTEM #3 (BID OPTION 002)
OVERRIDE SWITCH FOR SOLAR
LIGHTING SYSTEM #3 (BID OPTION 002).
MOUNT 48-IN AFG.
DESCRIPTION
SHEET
DATEP.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
USDA AGRICULTURAL RESEARCH CENTER
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson McAdams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
C:
\U se rs\ tjo hn so n.J
MC
FI
RM
\A pp Da ta\ Lo ca l\T em p\A cP ub lis h_
\E
0.d wg
F eb
, 2
4 -
8:
am
Agricultural
Service Research
USDA CFTRL
MOORE FIELD
EDINBURG, TEXAS
HAY BARN DESIGN
BID OPTION 002
SCHEDULES
E-600 14 1402/29/24
JGM
BSN
DRL 2150 CENTRE AVENUE
B. DEAN
D. CORDRAY
W. ROSS
CONTROLLER #1
SYSTEM BATTERY
LIGHTS
PANEL ARRAY
SM
CONTROLLER #2
SYSTEM BATTERY
LIGHTS
PANEL ARRAY
SM
CONTROLLER #3
SYSTEM BATTERY
LIGHTS
PANEL ARRAY
S
ON-OFF-AUTO
OVERRIDE
SP
SCALE:
SYSTEM #1 DIAGRAM
N.T.S.
E-600 SCALE:
SYSTEM #2 DIAGRAM
N.T.S.
E-600
SCALE:
SYSTEM #3 DIAGRAM
N.T.S.
E-600
LIGHTING SCHEDULE
MARK DESCRIPTION MOUNTING
A LED CANOPY FIXTURE SURFACE MOUNT TO CONTAINER CEILING
W LED AREA LIGHT WALL MOUNT 12-FT AFF
W W
A A A A A A A A
| Architecture |
| Sheets and Views |
| G-001 |
| A-001 |
| A-002 |
| A100 |
| A101 |
| A102 |
| A103 |
| A200 |
| A300 |
| Electrical |
| Sheets and Views |
| E-001 |
| E-101 |
| E-102 |
| E-200 |
| E-600 |
File details come from the government source that posted it. Updated .