BASIC 6®

Conquer extreme temperatures and stagnant air with the economical Basic 6.

Its durable design and smooth, powerful performance keep challenging work conditions from holding your business down. Backed by Big Ass Fans’ world-class customer support and in-field services, Basic 6 is your best entry-level option for airflow that sets your people up for success.

KEY FEATURES

DISCOVER MORE

ABOUT BASIC 6

Learn more at bigassfans.com/basic-6 or call 877.BIG.FANS for a free custom quote.

� Six aluminum airfoils with winglets and safety restraints

� Sealed helical gearbox and industrial motor for smooth, durable operation

� Machine-cut hub system evenly distributes load and promotes long life

� Redundant safety features keep workers cool without worry

� Variable speed operation with convenient digital touchscreen controller

� Wide airflow coverage improves existing HVAC efficiency

14–24 FEET

(4.3–7.3 METERS)

DIAMETER

INDUSTRIAL GRADE

WITH DOUBLE

LIP-SEALED GEARBOX

MOTOR

UP TO

7 YEARS

MECHANICAL

UP TO

3 YEARS

ELECTRICAL

WARRANTY

I-BEAMS, BAR JOISTS,

SOLID BEAMS, AND PURLINS

MOUNTING

Technical SpecificaTionS

USA

BIGASSFANS.COM

877-244-3267

CANADA

BIGASSFANS.COM

844-924-4277

AUSTRALIA

BIGASSFANS.COM/AU

1300 244 277

SINGAPORE

BIGASSFANS.COM/SG

65 6709 8500

Basic 6

Specifications subject to change without notice.© 2018 Delta T LLC dba Big Ass Fans. All rights reserved. | BC6-MKTG-150-ENG-01 REV. M | 02/23/23

MADE TO MOVE AIR, PLAIN AND SIMPLE

Technical Specifications

Diameter (A) Weight1 Max Speed Input Power and Required Breaker

Motor Horsepower Airfoil Clearances Max Operating

Temperature

14 ft (4.3 m) 192 lb (87.1 kg) 110 RPM

200–240 VAC, 50/60 Hz, 1 Φ, 25 A 200–240 VAC, 50/60 Hz, 3 Φ, 15 A 400–480 VAC, 50/60 Hz, 3 Φ, 10 A 575–600 VAC, 50/60 Hz, 3 Φ, 10 A

1.5 hp (1.1 kW)

2 ft (0.6 m) on sides 5 ft (1.5 m) below ceiling

104°F (40°C)

16 ft (4.9 m) 204 lb (92.5 kg) 98 RPM

2.0 hp (1.5 kW)

2 ft (0.6 m) on sides 6 ft (1.8 m) below ceiling18 ft (5.5 m) 210 lb (95.2 kg) 86 RPM

20 ft (6.1 m) 217 lb (98.4 kg) 76 RPM 2 ft (0.6 m) on sides 7 ft (2.1 m) below ceiling24 ft (7.3 m) 231 lb (104.8 kg) 61 RPM

Construction Features Airfoils Motor and Drive3 Certifications Mounting Multi-Point Safety4 Colors

Six patented Powerfoil airfoils (mill finish)

Powerfoil winglets eliminate wind noise

(BAF yellow)

Industrial-grade motor and gearbox feature inline helical-cut gears for efficient, durable, and reliable operation; lubricated for life with synthetic oil

Onboard NEMA 4X VFD eliminates RFI and EMI noise

UL Standard 507 and CSA Standard 22.2 No. 113

Standard upper mount installs to I-beams and bar joists

Extension tubes available in 2, 5, or 10 ft (0.6, 1.5, or 3 m) lengths

Optional kits allow for mounting to solid beams and purlins

Double safety cable system, airfoil retainers, hub safety clips, Grade 8 hardware, fire relay, guy wires, and airfoil restraint system

Standard colors are silver and yellow.

Individualize your fan with one of our classic color upgrades, or work with our design consultants to create a shade that’s all your own.

Standard Controller Construction Controls

Made from durable UV-resistant materials

Rated IP55

Intuitive touchscreen interface

On/Off and variable speed control

Password protection

Powered by fan drive

Lead times may vary.

See full warranty for coverage information.

Standard Controller

Height: 4.86 in. (123 mm) Width: 4.54 in. (115 mm) Depth: 1.3 in. (29 mm)

¹ Weight does not include mount or extension tube.

2 Measure the distance from the tip of the winglet to the ceiling or major obstruction.

3 The VFD is not preinstalled on the fan. Mounting the VFD onboard the fan requires field installation.

4 Airfoil restraint system comes standard on 20 –24 ft (6–7.3 m) fans and is an option for smaller diameter fans. The fire relay must be wired during install if required by local code.