BOM.xlsx

XLSX spreadsheet 48 KB Posted

Attached to
Communications Building, Transportation and Installation Federal contract opportunity
Solicitation number
12760418Q0026
Issued by
Department of Agriculture Forest Service Washington Office Acquisitions

About this file

Bill of Materials

View the file

Other files for this federal contract opportunity

Other files attached to Communications Building, Transportation and Installation, newest first.
File Type Posted
Delivery_locations.docx DOCX document
PWS.docx DOCX document
GPATLMRFY18LifeCycle.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Summary

RegionShip toForest/DistrictSITEPOCBOM Amount
R6Deschutes NFR6 Bend/FT Rock RDLookout 8x8x8 ShelterKen Jones$0.00
R9Huron/Manistee NFHuron/Manistee NF, Huron Shores RDSilver Valley 8x10x8 ShelterMark Carra, Shaun Schnepel$0.00
R2White River NFAspen/Sopris RDSunlight 8x8x8 ShelterJeff Scott$0.00
R9Monongahela NFGreenbrier RDBarton Knob 8x10x8 ShelterBrian Post$0.00

TOTALS $0.00

R6 Lookout Deschutes 8x8 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R6 Bend/FT Rock RD, Deschutes NF
Point of Contact (Local SAT):Marc Kaschmitter
Phone (Local SAT):
Street Address:80 SE Miller Ave
City, State:Bend, OR
Zip:97702
Additional Information needed for request.
Project Point of Contact (name and phone):Marc Kaschmitter
Additional Technical Contact (name and phone), if applicable:Ken Jones
WR # or Incident Number:20181914
Override/Job Code:2505/CMRD0518
Q-CODEQ0141918
UIA110706151419
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#20181914 001
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton (530) 226-2779
Comments:Lookout Mtn communications site Latitude N43 48' 7.81", Longitude W121 41' 49.98", Elevation 6225 ft. Door location: East, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 9.3' wide x 9.3' long x 8' highEA1
3Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter.$ - 0
4SPECIAL FEATURES:$ - 0
5Bullet proof walls$ - 0
62 hour fire rating$ - 0
7Insulation R20 average throughout.$ - 0
8ROOF AND FLOOR$ - 0
9Roof coating: EPDM$ - 0
10Flooring: Standard tile$ - 0
11INTERIOR WALLS AND CEILING:$ - 0
12FRP (Fiber-Reinforced Plastic) covered plywood$ - 0
13DOOR: Direction East$ - 0
143070 Door, 18 Gauge GalvanizedEA1$ - 0
153070 Frame, 16 Gauge GalvanizedEA1$ - 0
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1$ - 0
17Lock: 626-Entry w/deadbolt functionEA1$ - 0
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1$ - 0
18Latch Protector (SS)EA1$ - 0
19Door PullEA2$ - 0
20Magnetic Weather StrippingEA1$ - 0
21Drip Cap: 76" x 2-1/2"EA1$ - 0
22SS Hinges: Ball BearingEA3$ - 0
23Threshold: Bumper 36"EA1$ - 0
24Threshold: Saddle 36"EA1$ - 0
23CABLE TRAY:$ - 0
2414 linear feet of 12" wide steel cable trays$ - 0
25CABLE ENTRY:$ - 0
268 port cable entry$ - 0
27ELECTRICAL:$ - 0
28120V/240V, 200A, single phase$ - 0
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1$ - 0
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1$ - 0
31GROUNDING:$ - 0
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1$ - 0
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1$ - 0
344 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.$ - 0
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1$ - 0
36INTERIOR LIGHTS:$ - 0
3748" 40 wattEA2$ - 0
38RECEPTACLES:$ - 0
3920 Amp Specification grade Quad receptaclesEA4$ - 0
4020 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1$ - 0
41EQUIPMENT RACKS$ - 0
422 post, floor mounted 19" Equipment rackEA3$ - 0
43SAFETY EQUIPMENT:$ - 0
44Fire Extinguisher: Electrical ratedEA1$ - 0
45Eye Wash StationEA1$ - 0
46Smoke DetectorEA1$ - 0
50OTHER:$ - 0
51Service Manual detailing location of key shelter components$ - 0
52Shelter drawings$ - 0
53Backhaul 6'X6' fiberglass shelter to Bend OREA$ - 0
54$ - 0
55Transportation to R6EA1
56Installation with CraneEA1
57
58Delivery Address: USFS Service Center, 80 SE Miller Ave, Bend, OR 97702. Offload required by vendor.
59$ - 0
60GRAND TOTAL$ - 0

R9 Silver Valley 8X10 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:Huron Shores RD, Huron/Manistee NF
Point of Contact (Local SAT):Mark Carra
Phone (Local SAT):
Street Address:See installation instructions
City, State:
Zip:
Additional Information needed for request.
Project Point of Contact (name and phone):Shaun Schnepel
Additional Technical Contact (name and phone), if applicable:Kevin Throop
WR # or Incident Number:20182942
Override/Job Code:2505/CMRD0518
Real property Job codeQ5027318
UAI (Uniqe Asset Identification)1107090450273
AAP #:RPSH
POW Line Item # and Project DescriptionR9 Huron/Manistee NF, Huron Shores RD, Silver Valley 8x10x8 Building
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:
Comments:Door on East side, Cable entry on North side. AC entry South side, HAVC West side
LAT/LONG:Latitude: N44 22'33.55", Latitude: W83 35'59.36" Elevation 850 ft.
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

18x10x8 Walk-in Enclosure , Which includes Specifications belowBrand Name, or equivalent okEA1
2Size Nominal 8' Wide exterior x Nominal 10' x Nominal 8' high interior, one room concrete shelter.
3SPECIAL FEATURES:
4Door weather overhang
5Bullet proof walls
62 hour fire rating
7ROOF AND FLOOR
8Roof coating: EPDM (Ethylene Propylene Diene Monomer)
9Flooring: Standard tile
10Floor load capacity: 200 psf throughout and 500 psf concentrated load
11INTERIOR WALLS AND CEILING:
12FRP (Fiber-Reinforced Plastic)
13DOOR: Direction South
14Galvanized Frame: 3'6" x 7'0" x 4 3/4" with E.O.W.EA1
15Galvanized door: 3'6" x 7'0" x 1 3/4"EA1
16Hinges: Ball bearing hinge with non removable pinEA3
17Rain Drip and weather-strippingEA1
18Hydraulic closerEA1
19Miscellaneous items: Door stop, open door hook, Heavy duty crash chain, door pull, and 6" lock guard.
20DOOR LOCK:
21SFIC coreEA1
22DeadboltEA1
23V-wedge closuresEA1
24CABLE TRAY:
2525 linear feet of 12" wide steel cable traysEA1
26CABLE ENTRY: East side of building
27(4) 4' entry ports that will support standard rubber entry boots.EA1
28ELECTRICAL:
29120V/240V, 200A, single phase
3030 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1
31Type 1 Single phase hardware surge suppressorEA1
32GROUNDING:
332 awg Halo ground with break approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1
34One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss barEA1
355 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.
36Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1
37Provide conduit directly beneath MGB to the outside of the building.EA1
38INTERIOR LIGHTS:
3948" LED lightsEA3
40RECEPTACLES:
4120 Amp Specification grade duplex receptaclesEA10
4220 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1
43Circuit Breakers for contractor installed equipment and customer loads as specified
44WIRING CONDUIT:
45All wiring will be installed in surface mounted conduit or wire ways and will be in full compliance with ANSI/NFPA-70 - The national Electric Code, Latest Version
46EQUIPMENT RACKS
477 foot tall 2 post, floor mounted 19" Equipment rack5
48SAFETY EQUIPMENT:
49Fire Extinguisher: Electrical ratedEA1
50First Aid KitEA1
51VENTILATION HVAC
52Standard Efficiency 1-ton with economizer
539EER 208/230V Single phase, 60Hz.
54Heat
55Includes: Thermostat, supply grill, return grill.
56OTHER:
57Service Manual detailing location of key shelter componentsEA1
58Shelter drawingsEA3
59TransportationEA1
60Crane for offload at siteEA1
61Site driving directions: From Tawas City head North on Wilber Road, Turn west on Monument Rd, turn east on Tuttle Rd, proceed 1/4 mile to Forest service gate on left.
62Road information: paved road up to forest gate. From forest gate to site is gravel (250 feet) with one sharp turn.
Sub-Total
$ - 0
GRAND TOTAL$ - 0

R2 Sunlight 8x8 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R2 Aspen/Sopris RD, White River NF
Point of Contact (Local SAT):Jeff Scott
Phone (Local SAT):
Street Address:1168 County Road 116
City, State:Glenwood Springs, CO
Zip:81601
Additional Information needed for request.
Project Point of Contact (name and phone):Jeff Scott
Additional Technical Contact (name and phone), if applicable:Clayton Terrell
WR # or Incident Number:201810271
Override/Job Code:2505/CMRD0518
Q-CODEQ0038718
UIA110702150387
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#201810271
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton (530) 226-2779
Comments:Sunlight Pk communications site Latitude N39 50' 59.4", Longitude W107 18' 26.6", Elevation 10572 ft. Door location: West, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 8' wide x 8' long x 9' highEA1
3Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter.$ - 0
4SPECIAL FEATURES:$ - 0
5Bullet proof walls$ - 0
62 hour fire rating$ - 0
7Insulation R20 average throughout.$ - 0
8ROOF AND FLOOR$ - 0
9Roof coating: EPDM$ - 0
10Flooring: Standard tile$ - 0
11INTERIOR WALLS AND CEILING:$ - 0
12FRP (Fiber-Reinforced Plastic) covered plywood$ - 0
13DOOR: Direction East$ - 0
143070 Door, 18 Gauge GalvanizedEA1$ - 0
153070 Frame, 16 Gauge GalvanizedEA1$ - 0
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1$ - 0
17Lock: 626-Entry w/deadbolt functionEA1$ - 0
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1$ - 0
18Latch Protector (SS)EA1$ - 0
19Door PullEA2$ - 0
20Magnetic Weather StrippingEA1$ - 0
21Drip Cap: 76" x 2-1/2"EA1$ - 0
22SS Hinges: Ball BearingEA3$ - 0
23Threshold: Bumper 36"EA1$ - 0
24Threshold: Saddle 36"EA1$ - 0
23CABLE TRAY:$ - 0
2414 linear feet of 12" wide steel cable trays$ - 0
25CABLE ENTRY:$ - 0
268 port cable entry$ - 0
27ELECTRICAL:$ - 0
28120V/240V, 200A, single phase$ - 0
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1$ - 0
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1$ - 0
31GROUNDING:$ - 0
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1$ - 0
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1$ - 0
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1$ - 0
36INTERIOR LIGHTS:$ - 0
3748" 40 wattEA2$ - 0
38RECEPTACLES:$ - 0
3920 Amp Specification grade Dual receptaclesEA4$ - 0
4020 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1$ - 0
41EQUIPMENT RACKS$ - 0
422 post, floor mounted 19" Equipment rackEA2$ - 0
43SAFETY EQUIPMENT:$ - 0
44Fire Extinguisher: Electrical ratedEA1$ - 0
45Eye Wash StationEA1$ - 0
46Smoke DetectorEA1$ - 0
47COMFORT/CONVENIENCE:$ - 0
48Exhaust Fan 600 cfm 12" x 12"EA1$ - 0
49Louver Motorized - 12" x 12"EA1$ - 0
50OTHER:$ - 0
51Service Manual detailing location of key shelter components$ - 0
52Shelter drawings$ - 0
53Backhaul 8'X8' Shelter to Glenwood Springs, CO$ - 0
54$ - 0
55Transportation to R2EA1
56Installation with CraneEA1
57
58Delivery Address: Airport Shop, 1168 County Road 116, Glenwood Springs, CO 81601. Offload required by vendor.
59$ - 0
60GRAND TOTAL$ - 0

R9 Barton Knob 8x10 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R9 Greenbrier RD, Monongahela NF
Point of Contact (Local SAT):Brian Post
Phone (Local SAT):
Street Address:731 Yokum St
City, State:Elkins, WV
Zip:26250
Additional Information needed for request.
Project Point of Contact (name and phone):Brian Post
Additional Technical Contact (name and phone), if applicable:Cliff Guntly
WR # or Incident Number:20182749
Override/Job Code:2505/CMRD0518
Q-CODEQ3741018
UIA1107092137410
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#20182749
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton (530) 226-2779
Comments:Barton Knob communications site Latitude N38 37' 0", Longitude W79 55' 46", Elevation 4407 ft. Door location: North, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 8' wide x 10' long x 8' highEA1$ - 0
3Interior Dimensions: 6'8" wide x 8'8" long x 8' high ceiling$ - 0
4SPECIAL FEATURES:$ - 0
5Bullet proof walls$ - 0
62 hour fire rating$ - 0
7Insulation R20 average throughout.$ - 0
8ROOF AND FLOOR$ - 0
9Roof coating: EPDM$ - 0
10Flooring: Standard tile$ - 0
11INTERIOR WALLS AND CEILING:$ - 0
12FRP (Fiber-Reinforced Plastic) covered plywood$ - 0
13DOOR: Direction East$ - 0
143070 Door, 18 Gauge GalvanizedEA1$ - 0
153070 Frame, 16 Gauge GalvanizedEA1$ - 0
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1$ - 0
17Lock: 626-Entry w/deadbolt functionEA1$ - 0
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1$ - 0
18Latch Protector (SS)EA1$ - 0
19Door PullEA2$ - 0
20Magnetic Weather StrippingEA1$ - 0
21Drip Cap: 76" x 2-1/2"EA1$ - 0
22SS Hinges: Ball BearingEA3$ - 0
23Threshold: Bumper 36"EA1$ - 0
24Threshold: Saddle 36"EA1$ - 0
23CABLE TRAY:$ - 0
2416 linear feet of 12" wide steel cable trays$ - 0
25CABLE ENTRY:$ - 0
268 port cable entry$ - 0
27ELECTRICAL:$ - 0
28120V/240V, 200A, single phase$ - 0
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1$ - 0
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1$ - 0
31GROUNDING:$ - 0
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1$ - 0
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1$ - 0
344 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.$ - 0
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1$ - 0
36INTERIOR LIGHTS:$ - 0
3748" 40 wattEA4$ - 0
38RECEPTACLES:$ - 0
39Receptacle: DualEA8$ - 0
40Receptacle: GFIEA1$ - 0
41EQUIPMENT RACKS$ - 0
422 post, floor mounted 19" Equipment rackEA1$ - 0
43SAFETY EQUIPMENT:$ - 0
44Fire Extinguisher: Electrical ratedEA1$ - 0
45Eye Wash StationEA1$ - 0
46Smoke DetectorEA1$ - 0
47COMFORT/CONVENIENCE:$ - 0
48Exhaust Fan 600 cfm 12" x 12"EA1$ - 0
49Louver Motorized - 12" x 12"EA1$ - 0
50OTHER:$ - 0
51Service Manual detailing location of key shelter components$ - 0
52Shelter drawings$ - 0
53Solar Anchor Points
54$ - 0
55Transportation to R9EA1$ - 0
56Installation with CraneEA1$ - 0
57
58Delivery Address: Monongahela NF Depot, 731 Yokum St, Elkins, WV 26250. Offload required by vendor.
59$ - 0
60GRAND TOTAL$ - 0

File details come from the government source that posted it.