Summary
| Region | Ship to | Forest/District | SITE | POC | BOM Amount |
| R6 | Deschutes NF | R6 Bend/FT Rock RD | Lookout 8x8x8 Shelter | Ken Jones | $0.00 |
| R9 | Huron/Manistee NF | Huron/Manistee NF, Huron Shores RD | Silver Valley 8x10x8 Shelter | Mark Carra, Shaun Schnepel | $0.00 |
| R2 | White River NF | Aspen/Sopris RD | Sunlight 8x8x8 Shelter | Jeff Scott | $0.00 |
| R9 | Monongahela NF | Greenbrier RD | Barton Knob 8x10x8 Shelter | Brian Post | $0.00 |
TOTALS $0.00
R6 Lookout Deschutes 8x8 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R6 Bend/FT Rock RD, Deschutes NF | |
| Point of Contact (Local SAT): | Marc Kaschmitter | |
| Phone (Local SAT): | ||
| Street Address: | 80 SE Miller Ave | |
| City, State: | Bend, OR | |
| Zip: | 97702 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Marc Kaschmitter | |
| Additional Technical Contact (name and phone), if applicable: | Ken Jones | |
| WR # or Incident Number: | 20181914 | |
| Override/Job Code: | 2505/CMRD0518 | |
| Q-CODE | Q0141918 | |
| UIA | 110706151419 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#20181914 001 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton (530) 226-2779 | |
| Comments: | Lookout Mtn communications site Latitude N43 48' 7.81", Longitude W121 41' 49.98", Elevation 6225 ft. Door location: East, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 9.3' wide x 9.3' long x 8' high | EA | 1 | |||
| 3 | Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter. | $ - 0 | ||||
| 4 | SPECIAL FEATURES: | $ - 0 | ||||
| 5 | Bullet proof walls | $ - 0 | ||||
| 6 | 2 hour fire rating | $ - 0 | ||||
| 7 | Insulation R20 average throughout. | $ - 0 | ||||
| 8 | ROOF AND FLOOR | $ - 0 | ||||
| 9 | Roof coating: EPDM | $ - 0 | ||||
| 10 | Flooring: Standard tile | $ - 0 | ||||
| 11 | INTERIOR WALLS AND CEILING: | $ - 0 | ||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | $ - 0 | ||||
| 13 | DOOR: Direction East | $ - 0 | ||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | $ - 0 | ||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | $ - 0 | ||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | $ - 0 | ||
| 18 | Latch Protector (SS) | EA | 1 | $ - 0 | ||
| 19 | Door Pull | EA | 2 | $ - 0 | ||
| 20 | Magnetic Weather Stripping | EA | 1 | $ - 0 | ||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | $ - 0 | ||
| 22 | SS Hinges: Ball Bearing | EA | 3 | $ - 0 | ||
| 23 | Threshold: Bumper 36" | EA | 1 | $ - 0 | ||
| 24 | Threshold: Saddle 36" | EA | 1 | $ - 0 | ||
| 23 | CABLE TRAY: | $ - 0 | ||||
| 24 | 14 linear feet of 12" wide steel cable trays | $ - 0 | ||||
| 25 | CABLE ENTRY: | $ - 0 | ||||
| 26 | 8 port cable entry | $ - 0 | ||||
| 27 | ELECTRICAL: | $ - 0 | ||||
| 28 | 120V/240V, 200A, single phase | $ - 0 | ||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | $ - 0 | ||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | $ - 0 | ||
| 31 | GROUNDING: | $ - 0 | ||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | $ - 0 | ||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | $ - 0 | ||
| 34 | 4 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | $ - 0 | ||||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | $ - 0 | ||
| 36 | INTERIOR LIGHTS: | $ - 0 | ||||
| 37 | 48" 40 watt | EA | 2 | $ - 0 | ||
| 38 | RECEPTACLES: | $ - 0 | ||||
| 39 | 20 Amp Specification grade Quad receptacles | EA | 4 | $ - 0 | ||
| 40 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | $ - 0 | ||
| 41 | EQUIPMENT RACKS | $ - 0 | ||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 3 | $ - 0 | ||
| 43 | SAFETY EQUIPMENT: | $ - 0 | ||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | $ - 0 | ||
| 45 | Eye Wash Station | EA | 1 | $ - 0 | ||
| 46 | Smoke Detector | EA | 1 | $ - 0 | ||
| 50 | OTHER: | $ - 0 | ||||
| 51 | Service Manual detailing location of key shelter components | $ - 0 | ||||
| 52 | Shelter drawings | $ - 0 | ||||
| 53 | Backhaul 6'X6' fiberglass shelter to Bend OR | EA | $ - 0 | |||
| 54 | $ - 0 | |||||
| 55 | Transportation to R6 | EA | 1 | |||
| 56 | Installation with Crane | EA | 1 | |||
| 57 | ||||||
| 58 | Delivery Address: USFS Service Center, 80 SE Miller Ave, Bend, OR 97702. Offload required by vendor. | |||||
| 59 | $ - 0 | |||||
| 60 | GRAND TOTAL | $ - 0 |
R9 Silver Valley 8X10 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | |||||
| Unit Name to Ship to: | Huron Shores RD, Huron/Manistee NF | ||||
| Point of Contact (Local SAT): | Mark Carra | ||||
| Phone (Local SAT): | |||||
| Street Address: | See installation instructions | ||||
| City, State: | |||||
| Zip: | |||||
| Additional Information needed for request. | |||||
| Project Point of Contact (name and phone): | Shaun Schnepel | ||||
| Additional Technical Contact (name and phone), if applicable: | Kevin Throop | ||||
| WR # or Incident Number: | 20182942 | ||||
| Override/Job Code: | 2505/CMRD0518 | ||||
| Real property Job code | Q5027318 | ||||
| UAI (Uniqe Asset Identification) | 1107090450273 | ||||
| AAP #: | RPSH | ||||
| POW Line Item # and Project Description | R9 Huron/Manistee NF, Huron Shores RD, Silver Valley 8x10x8 Building | ||||
| Contract Number and Vendor, if applicable: | |||||
| Vendor address, point of contact name and phone number, if applicable: | |||||
| COR, if applicable: | |||||
| Comments: | Door on East side, Cable entry on North side. AC entry South side, HAVC West side | ||||
| LAT/LONG: | Latitude: N44 22'33.55", Latitude: W83 35'59.36" Elevation 850 ft. | ||||
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | 8x10x8 Walk-in Enclosure , Which includes Specifications below | Brand Name, or equivalent ok | EA | 1 | ||
| 2 | Size Nominal 8' Wide exterior x Nominal 10' x Nominal 8' high interior, one room concrete shelter. | |||||
| 3 | SPECIAL FEATURES: | |||||
| 4 | Door weather overhang | |||||
| 5 | Bullet proof walls | |||||
| 6 | 2 hour fire rating | |||||
| 7 | ROOF AND FLOOR | |||||
| 8 | Roof coating: EPDM (Ethylene Propylene Diene Monomer) | |||||
| 9 | Flooring: Standard tile | |||||
| 10 | Floor load capacity: 200 psf throughout and 500 psf concentrated load | |||||
| 11 | INTERIOR WALLS AND CEILING: | |||||
| 12 | FRP (Fiber-Reinforced Plastic) | |||||
| 13 | DOOR: Direction South | |||||
| 14 | Galvanized Frame: 3'6" x 7'0" x 4 3/4" with E.O.W. | EA | 1 | |||
| 15 | Galvanized door: 3'6" x 7'0" x 1 3/4" | EA | 1 | |||
| 16 | Hinges: Ball bearing hinge with non removable pin | EA | 3 | |||
| 17 | Rain Drip and weather-stripping | EA | 1 | |||
| 18 | Hydraulic closer | EA | 1 | |||
| 19 | Miscellaneous items: Door stop, open door hook, Heavy duty crash chain, door pull, and 6" lock guard. | |||||
| 20 | DOOR LOCK: | |||||
| 21 | SFIC core | EA | 1 | |||
| 22 | Deadbolt | EA | 1 | |||
| 23 | V-wedge closures | EA | 1 | |||
| 24 | CABLE TRAY: | |||||
| 25 | 25 linear feet of 12" wide steel cable trays | EA | 1 | |||
| 26 | CABLE ENTRY: East side of building | |||||
| 27 | (4) 4' entry ports that will support standard rubber entry boots. | EA | 1 | |||
| 28 | ELECTRICAL: | |||||
| 29 | 120V/240V, 200A, single phase | |||||
| 30 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | |||
| 31 | Type 1 Single phase hardware surge suppressor | EA | 1 | |||
| 32 | GROUNDING: | |||||
| 33 | 2 awg Halo ground with break approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | |||
| 34 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar | EA | 1 | |||
| 35 | 5 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | |||||
| 36 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | |||
| 37 | Provide conduit directly beneath MGB to the outside of the building. | EA | 1 | |||
| 38 | INTERIOR LIGHTS: | |||||
| 39 | 48" LED lights | EA | 3 | |||
| 40 | RECEPTACLES: | |||||
| 41 | 20 Amp Specification grade duplex receptacles | EA | 10 | |||
| 42 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | |||
| 43 | Circuit Breakers for contractor installed equipment and customer loads as specified | |||||
| 44 | WIRING CONDUIT: | |||||
| 45 | All wiring will be installed in surface mounted conduit or wire ways and will be in full compliance with ANSI/NFPA-70 - The national Electric Code, Latest Version | |||||
| 46 | EQUIPMENT RACKS | |||||
| 47 | 7 foot tall 2 post, floor mounted 19" Equipment rack | 5 | ||||
| 48 | SAFETY EQUIPMENT: | |||||
| 49 | Fire Extinguisher: Electrical rated | EA | 1 | |||
| 50 | First Aid Kit | EA | 1 | |||
| 51 | VENTILATION HVAC | |||||
| 52 | Standard Efficiency 1-ton with economizer | |||||
| 53 | 9EER 208/230V Single phase, 60Hz. | |||||
| 54 | Heat | |||||
| 55 | Includes: Thermostat, supply grill, return grill. | |||||
| 56 | OTHER: | |||||
| 57 | Service Manual detailing location of key shelter components | EA | 1 | |||
| 58 | Shelter drawings | EA | 3 | |||
| 59 | Transportation | EA | 1 | |||
| 60 | Crane for offload at site | EA | 1 | |||
| 61 | Site driving directions: From Tawas City head North on Wilber Road, Turn west on Monument Rd, turn east on Tuttle Rd, proceed 1/4 mile to Forest service gate on left. | |||||
| 62 | Road information: paved road up to forest gate. From forest gate to site is gravel (250 feet) with one sharp turn. | |||||
| Sub-Total | ||||||
| $ - 0 | ||||||
| GRAND TOTAL | $ - 0 |
R2 Sunlight 8x8 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R2 Aspen/Sopris RD, White River NF | |
| Point of Contact (Local SAT): | Jeff Scott | |
| Phone (Local SAT): | ||
| Street Address: | 1168 County Road 116 | |
| City, State: | Glenwood Springs, CO | |
| Zip: | 81601 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Jeff Scott | |
| Additional Technical Contact (name and phone), if applicable: | Clayton Terrell | |
| WR # or Incident Number: | 201810271 | |
| Override/Job Code: | 2505/CMRD0518 | |
| Q-CODE | Q0038718 | |
| UIA | 110702150387 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#201810271 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton (530) 226-2779 | |
| Comments: | Sunlight Pk communications site Latitude N39 50' 59.4", Longitude W107 18' 26.6", Elevation 10572 ft. Door location: West, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 8' wide x 8' long x 9' high | EA | 1 | |||
| 3 | Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter. | $ - 0 | ||||
| 4 | SPECIAL FEATURES: | $ - 0 | ||||
| 5 | Bullet proof walls | $ - 0 | ||||
| 6 | 2 hour fire rating | $ - 0 | ||||
| 7 | Insulation R20 average throughout. | $ - 0 | ||||
| 8 | ROOF AND FLOOR | $ - 0 | ||||
| 9 | Roof coating: EPDM | $ - 0 | ||||
| 10 | Flooring: Standard tile | $ - 0 | ||||
| 11 | INTERIOR WALLS AND CEILING: | $ - 0 | ||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | $ - 0 | ||||
| 13 | DOOR: Direction East | $ - 0 | ||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | $ - 0 | ||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | $ - 0 | ||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | $ - 0 | ||
| 18 | Latch Protector (SS) | EA | 1 | $ - 0 | ||
| 19 | Door Pull | EA | 2 | $ - 0 | ||
| 20 | Magnetic Weather Stripping | EA | 1 | $ - 0 | ||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | $ - 0 | ||
| 22 | SS Hinges: Ball Bearing | EA | 3 | $ - 0 | ||
| 23 | Threshold: Bumper 36" | EA | 1 | $ - 0 | ||
| 24 | Threshold: Saddle 36" | EA | 1 | $ - 0 | ||
| 23 | CABLE TRAY: | $ - 0 | ||||
| 24 | 14 linear feet of 12" wide steel cable trays | $ - 0 | ||||
| 25 | CABLE ENTRY: | $ - 0 | ||||
| 26 | 8 port cable entry | $ - 0 | ||||
| 27 | ELECTRICAL: | $ - 0 | ||||
| 28 | 120V/240V, 200A, single phase | $ - 0 | ||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | $ - 0 | ||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | $ - 0 | ||
| 31 | GROUNDING: | $ - 0 | ||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | $ - 0 | ||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | $ - 0 | ||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | $ - 0 | ||
| 36 | INTERIOR LIGHTS: | $ - 0 | ||||
| 37 | 48" 40 watt | EA | 2 | $ - 0 | ||
| 38 | RECEPTACLES: | $ - 0 | ||||
| 39 | 20 Amp Specification grade Dual receptacles | EA | 4 | $ - 0 | ||
| 40 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | $ - 0 | ||
| 41 | EQUIPMENT RACKS | $ - 0 | ||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 2 | $ - 0 | ||
| 43 | SAFETY EQUIPMENT: | $ - 0 | ||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | $ - 0 | ||
| 45 | Eye Wash Station | EA | 1 | $ - 0 | ||
| 46 | Smoke Detector | EA | 1 | $ - 0 | ||
| 47 | COMFORT/CONVENIENCE: | $ - 0 | ||||
| 48 | Exhaust Fan 600 cfm 12" x 12" | EA | 1 | $ - 0 | ||
| 49 | Louver Motorized - 12" x 12" | EA | 1 | $ - 0 | ||
| 50 | OTHER: | $ - 0 | ||||
| 51 | Service Manual detailing location of key shelter components | $ - 0 | ||||
| 52 | Shelter drawings | $ - 0 | ||||
| 53 | Backhaul 8'X8' Shelter to Glenwood Springs, CO | $ - 0 | ||||
| 54 | $ - 0 | |||||
| 55 | Transportation to R2 | EA | 1 | |||
| 56 | Installation with Crane | EA | 1 | |||
| 57 | ||||||
| 58 | Delivery Address: Airport Shop, 1168 County Road 116, Glenwood Springs, CO 81601. Offload required by vendor. | |||||
| 59 | $ - 0 | |||||
| 60 | GRAND TOTAL | $ - 0 |
R9 Barton Knob 8x10 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R9 Greenbrier RD, Monongahela NF | |
| Point of Contact (Local SAT): | Brian Post | |
| Phone (Local SAT): | ||
| Street Address: | 731 Yokum St | |
| City, State: | Elkins, WV | |
| Zip: | 26250 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Brian Post | |
| Additional Technical Contact (name and phone), if applicable: | Cliff Guntly | |
| WR # or Incident Number: | 20182749 | |
| Override/Job Code: | 2505/CMRD0518 | |
| Q-CODE | Q3741018 | |
| UIA | 1107092137410 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#20182749 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton (530) 226-2779 | |
| Comments: | Barton Knob communications site Latitude N38 37' 0", Longitude W79 55' 46", Elevation 4407 ft. Door location: North, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 8' wide x 10' long x 8' high | EA | 1 | $ - 0 | ||
| 3 | Interior Dimensions: 6'8" wide x 8'8" long x 8' high ceiling | $ - 0 | ||||
| 4 | SPECIAL FEATURES: | $ - 0 | ||||
| 5 | Bullet proof walls | $ - 0 | ||||
| 6 | 2 hour fire rating | $ - 0 | ||||
| 7 | Insulation R20 average throughout. | $ - 0 | ||||
| 8 | ROOF AND FLOOR | $ - 0 | ||||
| 9 | Roof coating: EPDM | $ - 0 | ||||
| 10 | Flooring: Standard tile | $ - 0 | ||||
| 11 | INTERIOR WALLS AND CEILING: | $ - 0 | ||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | $ - 0 | ||||
| 13 | DOOR: Direction East | $ - 0 | ||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | $ - 0 | ||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | $ - 0 | ||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | $ - 0 | ||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | $ - 0 | ||
| 18 | Latch Protector (SS) | EA | 1 | $ - 0 | ||
| 19 | Door Pull | EA | 2 | $ - 0 | ||
| 20 | Magnetic Weather Stripping | EA | 1 | $ - 0 | ||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | $ - 0 | ||
| 22 | SS Hinges: Ball Bearing | EA | 3 | $ - 0 | ||
| 23 | Threshold: Bumper 36" | EA | 1 | $ - 0 | ||
| 24 | Threshold: Saddle 36" | EA | 1 | $ - 0 | ||
| 23 | CABLE TRAY: | $ - 0 | ||||
| 24 | 16 linear feet of 12" wide steel cable trays | $ - 0 | ||||
| 25 | CABLE ENTRY: | $ - 0 | ||||
| 26 | 8 port cable entry | $ - 0 | ||||
| 27 | ELECTRICAL: | $ - 0 | ||||
| 28 | 120V/240V, 200A, single phase | $ - 0 | ||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | $ - 0 | ||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | $ - 0 | ||
| 31 | GROUNDING: | $ - 0 | ||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | $ - 0 | ||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | $ - 0 | ||
| 34 | 4 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | $ - 0 | ||||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | $ - 0 | ||
| 36 | INTERIOR LIGHTS: | $ - 0 | ||||
| 37 | 48" 40 watt | EA | 4 | $ - 0 | ||
| 38 | RECEPTACLES: | $ - 0 | ||||
| 39 | Receptacle: Dual | EA | 8 | $ - 0 | ||
| 40 | Receptacle: GFI | EA | 1 | $ - 0 | ||
| 41 | EQUIPMENT RACKS | $ - 0 | ||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 1 | $ - 0 | ||
| 43 | SAFETY EQUIPMENT: | $ - 0 | ||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | $ - 0 | ||
| 45 | Eye Wash Station | EA | 1 | $ - 0 | ||
| 46 | Smoke Detector | EA | 1 | $ - 0 | ||
| 47 | COMFORT/CONVENIENCE: | $ - 0 | ||||
| 48 | Exhaust Fan 600 cfm 12" x 12" | EA | 1 | $ - 0 | ||
| 49 | Louver Motorized - 12" x 12" | EA | 1 | $ - 0 | ||
| 50 | OTHER: | $ - 0 | ||||
| 51 | Service Manual detailing location of key shelter components | $ - 0 | ||||
| 52 | Shelter drawings | $ - 0 | ||||
| 53 | Solar Anchor Points | |||||
| 54 | $ - 0 | |||||
| 55 | Transportation to R9 | EA | 1 | $ - 0 | ||
| 56 | Installation with Crane | EA | 1 | $ - 0 | ||
| 57 | ||||||
| 58 | Delivery Address: Monongahela NF Depot, 731 Yokum St, Elkins, WV 26250. Offload required by vendor. | |||||
| 59 | $ - 0 | |||||
| 60 | GRAND TOTAL | $ - 0 |
File details come from the government source that posted it.