BOM.xlsx
XLSX spreadsheet 29 KB Posted
- Attached to
- Communications Building, Transportation and Installation Federal contract opportunity
- Solicitation number
- 12760418Q0011
About this file
Bill of Materials - three tabs
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PWS.pdf | ||
| GPATLMRFY18LifeCycle.docx | DOCX document | |
| AckerLettertotheFileDR.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R6 Mitchell Peak 10x12 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R6 Mt St Helens RD, Gifford Pinchot NF | |
| Point of Contact (Local SAT): | Orlando Avalos | |
| Phone (Local SAT): | ||
| Street Address: | 501 E 5th Street Bldg 404 | |
| City, State: | Vancouver, WA | |
| Zip: | 98661 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Orlando Avalos | |
| Additional Technical Contact (name and phone), if applicable: | Russell McDonald | |
| WR # or Incident Number: | 20182835 001 | |
| Override/Job Code: | 2505/NFVW0518 | |
| Q-CODE | Q0287018 | |
| UIA | 110706032870 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#20182835 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton 530-226-2779 | |
| Comments: | Mitchell Peak communications site Latitude N46 01' 41.33", Longitude W122 10' 17.77", Elevation 3975 ft. Door location: East, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 11.3' wide x 13.3' long x 8' high | EA | 1 | $ - 0 | ||
| 3 | Size Nominal 10' Wide exterior x Nominal 12' x Nominal 8' high interior, one room concrete shelter. | |||||
| 4 | SPECIAL FEATURES: | |||||
| 5 | Bullet proof walls | |||||
| 6 | 2 hour fire rating | |||||
| 7 | Insulation R20 average throughout. | |||||
| 8 | ROOF AND FLOOR | |||||
| 9 | Roof coating: EPDM | |||||
| 10 | Flooring: Standard tile | |||||
| 11 | INTERIOR WALLS AND CEILING: | |||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | |||||
| 13 | DOOR: Direction East | |||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | |||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | |||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | |||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | |||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | |||
| 18 | Latch Protector (SS) | EA | 1 | |||
| 19 | Door Pull | EA | 2 | |||
| 20 | Magnetic Weather Stripping | EA | 1 | |||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | |||
| 22 | SS Hinges: Ball Bearing | EA | 3 | |||
| 23 | Threshold: Bumper 36" | EA | 1 | |||
| 24 | Threshold: Saddle 36" | EA | 1 | |||
| 23 | CABLE TRAY: | |||||
| 24 | 20 linear feet of 12" wide steel cable trays | |||||
| 25 | CABLE ENTRY: | |||||
| 26 | 5 port cable entry | |||||
| 27 | ELECTRICAL: | |||||
| 28 | 120V/240V, 200A, single phase | |||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | |||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | |||
| 31 | GROUNDING: | |||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | |||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | |||
| 34 | 4 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | |||||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | |||
| 36 | INTERIOR LIGHTS: | |||||
| 37 | 48" 40 watt | EA | 4 | |||
| 38 | RECEPTACLES: | |||||
| 39 | 20 Amp Specification grade Quad receptacles | EA | 8 | |||
| 40 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | |||
| 41 | EQUIPMENT RACKS | |||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | 6 | |||
| 43 | SAFETY EQUIPMENT: | |||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | |||
| 45 | Eye Wash Station | EA | 1 | |||
| 46 | Smoke Detector | EA | 1 | |||
| 47 | COMFORT/CONVENIENCE: | |||||
| 48 | Exhaust Fan 600 cfm 12" x 12" | EA | 1 | |||
| 49 | Louver Motorized - 12" x 12" | EA | 1 | |||
| 50 | OTHER: | |||||
| 51 | Service Manual detailing location of key shelter components | |||||
| 52 | Shelter drawings | |||||
| 53 | ||||||
| 54 | ||||||
| 55 | Transportation to R6 | EA | 1 | $ - 0 | ||
| 56 | Installation with Crane | EA | 1 | $ - 0 | ||
| 57 | ||||||
| 58 | Delivery Address: USFS, 501 E 5th St Bldg 404, Vancouver, WA 98661. Offload required by vendor. | |||||
| 59 | ||||||
| 60 | GRAND TOTAL | $ - 0 |
R6 Acker 8x8 Bill of Materials
| Shipping Information: Use one sheet per shipping location. | ||
| Unit Name to Ship to: | R6 Tiller RD, Umpqua NF | |
| Point of Contact (Local SAT): | Carson Watson | |
| Phone (Local SAT): | ||
| Street Address: | 2691 NE Diamond Lake Blvd | |
| City, State: | Roseburg, OR | |
| Zip: | 97470 | |
| Additional Information needed for request. | ||
| Project Point of Contact (name and phone): | Carson Watson | |
| Additional Technical Contact (name and phone), if applicable: | Dennis Brigante | |
| WR # or Incident Number: | 201810155 001 | |
| Override/Job Code: | 2505/CMRD0518 | |
| Q-CODE | Q0141918 | |
| UIA | 110706151419 | |
| BOC | 3220 | |
| AAP #: | RPSH | |
| POW Line Item # and Project Description | WR#201810155 | |
| Contract Number and Vendor, if applicable: | ||
| Vendor address, point of contact name and phone number, if applicable: | ||
| COR, if applicable: | Yana Patton 530-226-2779 | |
| Comments: | Acker Rock communications site Latitude N43 03' 16", Longitude W122 38' 49", Elevation 3776 ft. Door location: East, Tower: NA |
| LINE | |||||
| ITEM | DESCRIPTION | Manufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC. | Unit of Issue | QTY | UNIT |
| PRICE | TOTAL |
PRICE
| 1 | SHELTER DESCRIPTION | Brand Name, or equivalent ok | ||||
| 2 | Prefabricated Concrete Building 9.3' wide x 9.3' long x 8' high | EA | 1 | |||
| 3 | Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter. | |||||
| 4 | SPECIAL FEATURES: | |||||
| 5 | Bullet proof walls | |||||
| 6 | 2 hour fire rating | |||||
| 7 | Insulation R20 average throughout. | |||||
| 8 | ROOF AND FLOOR | |||||
| 9 | Roof coating: EPDM | |||||
| 10 | Flooring: Standard tile | |||||
| 11 | INTERIOR WALLS AND CEILING: | |||||
| 12 | FRP (Fiber-Reinforced Plastic) covered plywood | |||||
| 13 | DOOR: Direction East | |||||
| 14 | 3070 Door, 18 Gauge Galvanized | EA | 1 | |||
| 15 | 3070 Frame, 16 Gauge Galvanized | EA | 1 | |||
| 16 | Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb open | EA | 1 | |||
| 17 | Lock: 626-Entry w/deadbolt function | EA | 1 | |||
| 17 | Cylinder Housing, Combined Core, Control Keyway, Keys | EA | 1 | |||
| 18 | Latch Protector (SS) | EA | 1 | |||
| 19 | Door Pull | EA | 2 | |||
| 20 | Magnetic Weather Stripping | EA | 1 | |||
| 21 | Drip Cap: 76" x 2-1/2" | EA | 1 | |||
| 22 | SS Hinges: Ball Bearing | EA | 3 | |||
| 23 | Threshold: Bumper 36" | EA | 1 | |||
| 24 | Threshold: Saddle 36" | EA | 1 | |||
| 23 | CABLE TRAY: | |||||
| 24 | 14 linear feet of 12" wide steel cable trays | |||||
| 25 | CABLE ENTRY: | |||||
| 26 | 5 port cable entry | |||||
| 27 | ELECTRICAL: | |||||
| 28 | 120V/240V, 200A, single phase | |||||
| 29 | 30 space breaker panel with snap in breakers: NEMA 1 surface mount enclosure | EA | 1 | |||
| 30 | Type 1 Single phase hardware surge suppressor 120/240 1P | EA | 1 | |||
| 31 | GROUNDING: | |||||
| 32 | 2 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar. | EA | 1 | |||
| 33 | One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar. | EA | 1 | |||
| 34 | 4 Equipment rack ground bars connected to master ground bar with 2 AWG green cable. | |||||
| 35 | Provisions for the connection of a grounding electrode conductor at the shelter service equipment | EA | 1 | |||
| 36 | INTERIOR LIGHTS: | |||||
| 37 | 48" 40 watt | EA | 2 | |||
| 38 | RECEPTACLES: | |||||
| 39 | 20 Amp Specification grade Quad receptacles | EA | 4 | |||
| 40 | 20 Amp Specifications Exterior grade Duplex GFI Receptacle | EA | 1 | |||
| 41 | EQUIPMENT RACKS | |||||
| 42 | 2 post, floor mounted 19" Equipment rack | EA | ||||
| 43 | SAFETY EQUIPMENT: | |||||
| 44 | Fire Extinguisher: Electrical rated | EA | 1 | |||
| 45 | Eye Wash Station | EA | 1 | |||
| 46 | Smoke Detector | EA | 1 | |||
| 47 | COMFORT/CONVENIENCE: | |||||
| 48 | Exhaust Fan 600 cfm 12" x 12" | EA | 1 | |||
| 49 | Louver Motorized - 12" x 12" | EA | 1 | |||
| 50 | OTHER: | |||||
| 51 | Service Manual detailing location of key shelter components | |||||
| 52 | Shelter drawings | |||||
| 53 | ||||||
| 54 | ||||||
| 55 | Transportation to R6 | EA | 1 | |||
| 56 | Installation with Crane | EA | 1 | |||
| 57 | ||||||
| 58 | Delivery Address: USFS Service Center, 2691 NE Diamond Lake Blvd, Roseburg, OR 97470. Offload required by vendor. | |||||
| 59 | ||||||
| 60 | GRAND TOTAL | $ - 0 |
Summary
| Acker 8x8 | $ - 0 |
| Mitchell Peak 10x12 | $ - 0 |
| TOTAL | $ - 0 |
File details come from the government source that posted it.