BOM.xlsx

XLSX spreadsheet 29 KB Posted

Attached to
Communications Building, Transportation and Installation Federal contract opportunity
Solicitation number
12760418Q0011
Issued by
Department of Agriculture Forest Service Washington Office Acquisitions

About this file

Bill of Materials - three tabs

View the file

Other files for this federal contract opportunity

Other files attached to Communications Building, Transportation and Installation, newest first.
File Type Posted
PWS.pdf PDF
GPATLMRFY18LifeCycle.docx DOCX document
AckerLettertotheFileDR.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R6 Mitchell Peak 10x12 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R6 Mt St Helens RD, Gifford Pinchot NF
Point of Contact (Local SAT):Orlando Avalos
Phone (Local SAT):
Street Address:501 E 5th Street Bldg 404
City, State:Vancouver, WA
Zip:98661
Additional Information needed for request.
Project Point of Contact (name and phone):Orlando Avalos
Additional Technical Contact (name and phone), if applicable:Russell McDonald
WR # or Incident Number:20182835 001
Override/Job Code:2505/NFVW0518
Q-CODEQ0287018
UIA110706032870
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#20182835
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton 530-226-2779
Comments:Mitchell Peak communications site Latitude N46 01' 41.33", Longitude W122 10' 17.77", Elevation 3975 ft. Door location: East, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 11.3' wide x 13.3' long x 8' highEA1$ - 0
3Size Nominal 10' Wide exterior x Nominal 12' x Nominal 8' high interior, one room concrete shelter.
4SPECIAL FEATURES:
5Bullet proof walls
62 hour fire rating
7Insulation R20 average throughout.
8ROOF AND FLOOR
9Roof coating: EPDM
10Flooring: Standard tile
11INTERIOR WALLS AND CEILING:
12FRP (Fiber-Reinforced Plastic) covered plywood
13DOOR: Direction East
143070 Door, 18 Gauge GalvanizedEA1
153070 Frame, 16 Gauge GalvanizedEA1
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1
17Lock: 626-Entry w/deadbolt functionEA1
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1
18Latch Protector (SS)EA1
19Door PullEA2
20Magnetic Weather StrippingEA1
21Drip Cap: 76" x 2-1/2"EA1
22SS Hinges: Ball BearingEA3
23Threshold: Bumper 36"EA1
24Threshold: Saddle 36"EA1
23CABLE TRAY:
2420 linear feet of 12" wide steel cable trays
25CABLE ENTRY:
265 port cable entry
27ELECTRICAL:
28120V/240V, 200A, single phase
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1
31GROUNDING:
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1
344 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1
36INTERIOR LIGHTS:
3748" 40 wattEA4
38RECEPTACLES:
3920 Amp Specification grade Quad receptaclesEA8
4020 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1
41EQUIPMENT RACKS
422 post, floor mounted 19" Equipment rackEA6
43SAFETY EQUIPMENT:
44Fire Extinguisher: Electrical ratedEA1
45Eye Wash StationEA1
46Smoke DetectorEA1
47COMFORT/CONVENIENCE:
48Exhaust Fan 600 cfm 12" x 12"EA1
49Louver Motorized - 12" x 12"EA1
50OTHER:
51Service Manual detailing location of key shelter components
52Shelter drawings
53
54
55Transportation to R6EA1$ - 0
56Installation with CraneEA1$ - 0
57
58Delivery Address: USFS, 501 E 5th St Bldg 404, Vancouver, WA 98661. Offload required by vendor.
59
60GRAND TOTAL$ - 0

R6 Acker 8x8 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R6 Tiller RD, Umpqua NF
Point of Contact (Local SAT):Carson Watson
Phone (Local SAT):
Street Address:2691 NE Diamond Lake Blvd
City, State:Roseburg, OR
Zip:97470
Additional Information needed for request.
Project Point of Contact (name and phone):Carson Watson
Additional Technical Contact (name and phone), if applicable:Dennis Brigante
WR # or Incident Number:201810155 001
Override/Job Code:2505/CMRD0518
Q-CODEQ0141918
UIA110706151419
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#201810155
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Yana Patton 530-226-2779
Comments:Acker Rock communications site Latitude N43 03' 16", Longitude W122 38' 49", Elevation 3776 ft. Door location: East, Tower: NA
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical Specifications Identify as either 'Brand Name required' , or 'Brand Name, or equivalent ok'. If Brand Name required, separate those items out into a different request, with JOFOC.Unit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Concrete Building 9.3' wide x 9.3' long x 8' highEA1
3Size Nominal 8' Wide exterior x Nominal 8' x Nominal 8' high interior, one room concrete shelter.
4SPECIAL FEATURES:
5Bullet proof walls
62 hour fire rating
7Insulation R20 average throughout.
8ROOF AND FLOOR
9Roof coating: EPDM
10Flooring: Standard tile
11INTERIOR WALLS AND CEILING:
12FRP (Fiber-Reinforced Plastic) covered plywood
13DOOR: Direction East
143070 Door, 18 Gauge GalvanizedEA1
153070 Frame, 16 Gauge GalvanizedEA1
16Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1
17Lock: 626-Entry w/deadbolt functionEA1
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1
18Latch Protector (SS)EA1
19Door PullEA2
20Magnetic Weather StrippingEA1
21Drip Cap: 76" x 2-1/2"EA1
22SS Hinges: Ball BearingEA3
23Threshold: Bumper 36"EA1
24Threshold: Saddle 36"EA1
23CABLE TRAY:
2414 linear feet of 12" wide steel cable trays
25CABLE ENTRY:
265 port cable entry
27ELECTRICAL:
28120V/240V, 200A, single phase
2930 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1
30Type 1 Single phase hardware surge suppressor 120/240 1PEA1
31GROUNDING:
322 awg Halo ground approximately 6” below ceiling, master ground buss bar. Equipment racks with grounding bars with 2 awg connected and run to master ground bar.EA1
33One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1
344 Equipment rack ground bars connected to master ground bar with 2 AWG green cable.
35Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1
36INTERIOR LIGHTS:
3748" 40 wattEA2
38RECEPTACLES:
3920 Amp Specification grade Quad receptaclesEA4
4020 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1
41EQUIPMENT RACKS
422 post, floor mounted 19" Equipment rackEA
43SAFETY EQUIPMENT:
44Fire Extinguisher: Electrical ratedEA1
45Eye Wash StationEA1
46Smoke DetectorEA1
47COMFORT/CONVENIENCE:
48Exhaust Fan 600 cfm 12" x 12"EA1
49Louver Motorized - 12" x 12"EA1
50OTHER:
51Service Manual detailing location of key shelter components
52Shelter drawings
53
54
55Transportation to R6EA1
56Installation with CraneEA1
57
58Delivery Address: USFS Service Center, 2691 NE Diamond Lake Blvd, Roseburg, OR 97470. Offload required by vendor.
59
60GRAND TOTAL$ - 0

Summary

Acker 8x8$ - 0
Mitchell Peak 10x12$ - 0
TOTAL$ - 0

File details come from the government source that posted it.