Statement of Work.pdf
PDF 172 KB Posted
- Attached to
- Tilt Pan Scanner with Mirrors System - Sources Sought Federal contract opportunity
- Solicitation number
- 12505B24Q0219SS
About this file
This document is a Statement of Work (SOW) for a Tilt Pan Scanner with Mirrors system that can be used with a GasFinder3-OP NH3 laser. The SOW outlines the technical requirements and deliverables for the system, which must be capable of monitoring multiple active measurement paths, auto-light optimizing, and interfacing with existing GasFinder3-OP and GasViewMP software. The system is to be delivered within 90 days to the USDA-ARS National Laboratory for Agriculture and the Environment in Ames, IA.
The related federal contract opportunity is a Sources Sought notice issued by the USDA-ARS Midwest Area to determine if there are qualified small business vendors capable of providing the Tilt Pan Scanner with Mirrors system described in the SOW. Responses are requested from small businesses, disadvantaged businesses, HUBZone businesses, veteran-owned businesses, service-disabled veteran-owned businesses, women-owned businesses, and economically disadvantaged women-owned businesses. Capability statements and the completed Sources Sought Response Form must be submitted electronically by June 24, 2024. The Government will use the responses to determine the appropriate acquisition strategy, which may include a small business set-aside, unrestricted solicitation, or sole-source award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sources Sought Response Form.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work Project: Tilt Pan Scanner with Mirrors system for use with GasFinder3-OP Ammonia
(NH3) Laser
GENERAL INFORMATION
1.0 Scope of Work:
Provide a Tilt Pan Scanner with Mirrors system that can be use with a GasFinder3- OP NH3 laser.
2.0 Background:
This instrument to allow a single GasFinder3-OP laser to measure multiple locations and keep laser alignment over long periods.
CONTRACTOR REQUIREMENTS
3.0 Technical Requirements/Tasks:
• The tilt-pan scanner must be fully compatible and operate with an existing GasFinder3-OP laser
• The tilt-pan scanner must be capable of monitoring multiple active measurement paths (up to eight different successive retro-reflectors).
• The scanner must be capable of auto-light optimizing to maintain optimum optical alignment between the GasFinder3-OP laser and retro-reflector array.
• The scanner must be fully compatible with and controlled by GasViewMP software
• The scanner/controller must fully capable of interfacing with existing GasFinder3-OP and GasViewMP software and to be remotely operated with either a cell modem or radio modem
• System shall include Tilt Pan Scanner, with mirrors, power and control center module, tripod for scanner and two retro-reflectors
• Warranty: Standard warranty on OEM parts and technical support including remote diagnostics
• Qty: 1 complete Tilt Pan Scanner with mirrors system
4.0 Deliverables/Schedule:
Shall be delivered onsite within 90 days of award.
5.0 Place of Delivery:
USDA-ARS, The National Laboratory for Agriculture and the Environment (NLAE), 1015 North University Boulevard, Ames, IA, 50011.
6.0 Technical Point of Contact:
TBD at time of award.