C08_QAmemo-12445526Q0073.pdf

PDF 284 KB Posted

Attached to
SUF FR912 Little Isabella River Culvert Replacement Federal contract opportunity
Solicitation number
12445526Q0073
Issued by
Department of Agriculture Forest Service

About this file

This is a Questions and Answers memorandum issued by the United States Forest Service (USFS) Procurement Operations (PROPS) East Zone Team 3 Construction in response to RFQ 12445526Q0073, dated 25 June 2026. The document addresses a single inquiry regarding acceptable variations in culvert barrel and wing wall shapes for the contract requirements.

The Government's response clarifies that variations in culvert shape, such as radiused corners, are acceptable only if the fabricator can meet the clear cover requirements, steel reinforcing size, and steel reinforcing spacing as detailed in the Forest Service drawings. Similarly, variations in wing wall shape are permissible only if the fabricator meets the height and width requirements specified in the FS drawings, with the critical constraint that minimum dimensions for the wing wall footing toe (river side) and heel (road side) must be met. Matthew L. Killian, Contracting Officer for USFS PROPS EZ 3 CONS, issued this clarification on behalf of the Government.

View the file

Other files for this federal contract opportunity

Other files attached to SUF FR912 Little Isabella River Culvert Replacement, newest first.
File Type Posted
C05_0-SF30-12445526Q0073_A0003.pdf PDF
C08_QAmemo2-12445526Q0073.pdf PDF
C05_1-12445526Q0073_A0003-Att6-FillableSOI_Rev1.xlsx XLSX spreadsheet
C05_0-SF30-12445526Q0073_A0002.pdf PDF
C05_0-SF30-12445526Q0073_A0001.pdf PDF
C05_1-12445526Q0073_A0001-Att1-SOW_Rev1.pdf PDF
C04_1-12445526Q0073-Att2-Plans.pdf PDF
C04_1-12445526Q0073-Att6-FillableSOI.xlsx XLSX spreadsheet
C04_0-RFQ-12445526Q0073.pdf PDF
C04_1-12445526Q0073-Att1-SOW.docx DOCX document
C04_1-12445526Q0073-Att3-Map.jpg JPG image
C04_1-12445526Q0073-Att4-Specs.pdf PDF
C04_1-12445526Q0073-Att5-DBAWD-MN20260231.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNITED STATES FOREST SERVICE

PROCUREMENT OPERATIONS (PROPS)

EAST ZONE (EZ) TEAM 3 CONSTRUCTION (CONS)

25 June 2026

MEMORANDUM FOR RFQ 12445526Q0073

FROM USFS PROPS EZ 3 CONS

SUBJECT: RFQ 12445526Q0073 Questions & Answers

1. Question: “Would [the Government] accept variations of barrel and wing wall shapes as equal?”

Answer: “Variations of culvert shape (i.e. radiused corners) may be acceptable only if the fabricator can meet the clear cover requirements, steel reinforcing size, and steel reinforcing spacing detailed in the FS drawings. Variations of wing wall shape may be acceptable only if the fabricator can meet the height and width requirements detailed in the FS drawings. The minimum dimensions for the wing wall footing toe (river side) and heel (road side) must be met.”

MATTHEW L KILLIAN

Contracting Officer

USFS PROPS EZ 3 CONS

2026-06-25T08:25:07-0500
MATTHEW KILLIAN

File details come from the government source that posted it. Updated .