Att. 6 Shop Drawing & Submittal Sheets 337 - 34X8-NCDW22001 220815.pdf

PDF 1 MB Posted

Attached to
Gauley Storage Building - Monongahela National Forest, West Virginia
Solicitation number
12445522Q0162
Issued by

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

No.

Revisions

Sheet Title

Drawn By

Checked By

Date

Scale

Job Number

Revision

Sheet Number

Approved By

ByDate Item

General Notes and Details

KMS D0

NONE

8/12/2022

Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com

Structural Design Loads:

Live Loads:

Roof: 40 PSF (Snow) Grated Floor: 250 PSF Base: 500 PSF Wall, Roof & Floor: 100 PSF

Dead Loads:

Roof: 20 PSF Floor: 85 PSF Wall: 20 PSF

Wind Design Data: (Per IBC 2018) Risk Category II Basic Wind Speed - 150 Mph, 3 sec gust. Exposure Category - C

Seismic Design Data: Worst case Per IBC 2018

A) Dimensions - 34'6" X 8'2" X 8'-4" High.Exterior.

B) Spill Containment - Internal spill containment is a major design feature of the storage container. When filled with 55 gallon drums stored upright and unstacked, the container will contain a minimum of the total leakage from one-quarter (25%) of the drums. Spill Containment is 6" Deep.

C) Floor - The floor of the container is constructed of 10 gauge steel and incorporates a false floor system to prevent the release of hazardous liquids and solids if they are discharged from a primary container.

D) Walls & Roof - The walls and roof are fabricated using 16 GA Bent Wall Panels and Structural Wall Tubes.

E) Doors - Non Combustible Steel Units are Supplied with 16 Gauge Doors. The doors have a 3 pt. Locking Mechanism with a Padlock Hasp, Interior Safety Override and Door Hold Open.

F) Ventilation - The container is equipped with vents for natural ventilation.

G) Grounding - The container is equipped with one exterior static grounding connection.

H) Seismic Tie Down - The container is equipped with provisions for securing the building to the ground per seismic Zone 4 regulations.

Workmanship:

A) Steel Fabrication - The steel used to fabricate the container is free from kinks, and sharp bends. The manufacturing process does not reduce the strength of the steel to a value less than intended by the design. Each manufacturing process is done neatly and accurately, and all bends are made by controlled means to insure uniformity of size and shape.

B) Welding - The welding procedures employed are in accordance with the filler metal specifications of the American Welding Society and in cooperation with the ASTM. All welds are of sufficient size and shape to develop the full design strength of the parts connected by the welds. These welds transmit the imposed stresses without permanent deformation or failure when subject to proof of storage loads.

C) Painting - After a thorough cleaning process the exterior and interior of the container are painted with a self-priming chemical resistant durable urethane paint.

DESIGN DATA

INSTALLATION & END USER RESPONSIBILITIES

Gauley Storage Unit Monongahela National Forest Service Order 12444322F087 Job (337)34X8-NCDW22001

End User Responsibilities and Installation Instructions

End user is responsible for offloading, installation, permitting and proper use of the Building as required by their Local Jurisdiction. The Manufacturer is not responsible for any damage to people or property due to the misuse or in proper installation of its products. End user is responsible for determining proper storage and allowable quantities of hazardous materials used and stored within the building as well as proper classification of electrical equipment used within the structure. The Manufacturer is not responsible for any damage resulting from offloading or installation.

Offload Instructions: Building Weight is Approximately 17,000# Crane Rigging:

Forklift Pockets are Provided. All must be used to achieve a balanced lift. Crane Capacity is to be determined by the equipment handler based on the weight of the unit, type of lift and site conditions. Slings are to be placed through the forklift pockets provided. Buildings are to be supported at the middle and both end pockets. Spreader Bars are to be used to protect exterior mounted equipment.

Forklift Procedure:

Forklift Pockets are Provided. All must be used to achieve a balanced lift. Forklift Pockets must be used when lifting the buildings with a forklift. Any attempts to lift the buildings at other locations may result in damage to the floor of the unit. Appropriate Capacity is to be determined by the equipment handler based on the weight of the unit, site conditions and length of forks.

Installation Instructions/End User Responsibilities: Aerosol Touch up Paint is shipped inside the building.

1. Acquire all proper permitting for the use and installation of the unit as required by the local jurisdiction.

2. Contract with a Licensed Electrician to provide power to the load center. (If Provided)

3. Provide Level Surface Capable of Supporting the Weight of the Unit and contents/equipment to be stored.

4. Any dirt or water which enters the building during shipment must be clean and dry prior to using the building. Grating and supports are removable for clean-up of the secondary containment area.

5. Seal all holes made in the buildings to close openings for shipping with the Caulking Provided. (if applicable)

6. Inspect Building for Loose Grating Clips. Shipping and Handling may cause the Grating clips to become loose. Grating must be checked and secured prior to use of the building.

7. Inspect Building for Gaps along the interior of the forklift pockets and other interior and exterior seams. All seams are sealed with Caulking at the Factory as Required prior to paint and upon final shipping inspection. Gaps in the caulking may result from Transportation and Handling. All gaps must be sealed to prevent moisture intrusion prior to using the building.

8. Touch up any paint damaged during transportation, offloading or installation of the building to protect steel surfaces from rusting.

9. Dry Chemical Fire Suppression System: (If provided) The dry chemical fire extinguishing system is NOT armed during shipment. This system must be armed by a qualified technician. Disarm the system before relocation and arm it when relocation is complete. Fusible links should be replaced every six (6) months.

10. Anchor Building to foundation as required by local jurisdiction. Anchor Pads are provided as part of the building at all 4 corners. Any Engineering required for proper anchoring is the responsibility of the end user.

11.Your Chemical Storage Locker containment sump was leak tested at the factory. It is possible that improper handling during shipping could cause a fracture or rupture to the sump. It is strongly recommended that the locker be leveled, the sump filled with water and allowed to stand overnight. Any leaks should then be readily apparent. It is also recommended that this test be made each time the locker is relocated or after a spill clean-up. The booklet located inside your unit provides an inspection log. Sump inspections (at least every 72 hours) and all maintenance activity should be recorded.

12.Explosion Venting: (If provided) The explosion relief panel limiting chains have been secured for shipping. Remove tie downs (see tags on relief panels) before storing chemicals. If a roof mounted explosion relief cap is provided, it should be exercised monthly (with the application of a light oil if necessary) to keep the hinges free of rust and operating smoothly.

13.Forced Ventilation: (If provided) The intake and discharge ducts on the forced air circulation fan should be checked daily for obstructions, and the fan and damper hinge lubricated biannually.

4 X 3 X 38" Angle 4" X 3" X 38" Angle with 78" Hole Typ. at 4 Corners

SHEET INDEX

SHEET

NUMBER

SHEET TITLE

D0 GENERAL NOTES

D1 BASE AND ROOF ASSEMBLY

D2 WALL ASSEMBLY - DOUBLE WALL STEE; INSULATED

L1 EQUIPMENT LAYOUT VIEW

INTELLECTUAL PROPERTY

ANCHORING DETAILS

ELECTRICAL REQUIREMENTS

10 GA Bent Back Roof Supp.

G

A Be nt Ro of Jo ist

3" 3"

14 GA HRS Exterior Sheet Continuously Welded - Water Tight

10 GA 4 1/2" to 2 1/2" Bent Tapered Roof Support Front & Back. 4 14" to 2 14" Bent Tapered Roof Joint

2'-0" O.C.

2'

Side View 6" Deep Containment

C4X5.4 Floor Support 4X3X1

2 Angle

C6X8.2 Base Side

Roof Framing and Plan

3" 3"

3 8

Front Back

10 GA Bent Front & Back Support

10 GA Bent Side & Interior Roof Joists

Roof Supports

Roof Section Detail

2 Roof Joists at

Each End

Roof Joists Fit Inside

Front & Rear Roof

Supports

14 GA HRS Welded

Continously at all

Seams Water Tight

10 GA Bent Roof Joist

14 GA HRS

10 GA Bent

Roof Support

Front & Back

14 GA HRS Continuously Welded Water Tight Roof Seams Centered on Bent Supports

10 GA Bent Front Roof Supp.

No.

Revisions

Sheet Title

Drawn By

Checked By

Date

Scale

Job Number

Revision

Sheet Number

Approved By

ByDate Item

Base and Roof Assembly

KMS D1

NONE

8/12/2022

Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com

C6 X 8.2 Base Front and Rear

4X3X1 2 Angle

10GA

Floor Plate 8X4X 3

16" Forklift Pockets C4X5.4 Base Supports

10GA

Sump Plate

8X 4X

3 16 " F or kli ft P oc ke ts

Be low

C4 X5

.4 Ba se S up po rts B elo w

C6 X8

.2 Ba se S ide s

Base Assembly

4 X 3 X 12 Angle

C6 X 8.2 Base Sides

Removable Grating Support 12GA Galv

C4 X 5.4 Base Supports

10GA

Floor Plate

For welds not shown notes,

1. All Welds to be continuous at end connection all base and corner supports.

2. All Fillets weld to be the same thickness as the materials

3. Continuous welds at sump leak test

4. Fillet weld 3

16 to be 2" on 14" at corners supports both ends

5. 14 GA and 16 GA sheet metal welds @ wall supports to be 18" fillets 1" on 18" fillet welds each side of support minimum distortion on all wall panels and base.

6. Exterior sheet welds to be 18" filets 1" on 12" at Header on Exterior.

7. Exterior sheet welds to be continuous at Base on Interior.

6" Base Detail

Galvanized Steel Grating

CHEM-STOR

10 GA HRS Floor Sheets Continuously Welded at All Seams Leak Tested

10GA 72 X 96

Sump Plate

10GA 72 X 96

Sump Plate

10GA 72 X 96

Sump Plate

10GA 72 X 96

Sump Plate

10GA 72 X 96

Sump Plate

10GA 48 X 96

Sump Plate

14GA 48 X 96

Roof Sheet

14GA 24 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

14GA 48 X 96

Roof Sheet

R11 Insulation 20GA INT Sheet

Gauley Storage Unit Monongahela National Forest Service Order 12444322F087 Job (337)34X8-NCDW22001

No.

Revisions

Sheet Title

Drawn By

Checked By

Date

Scale

Job Number

Revision

Sheet Number

Approved By

ByDate Item

KMS D2

NONE

8/13/2022

TBD

Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com

Exterior Wall 14 GA Bent Corner with 16GA Bent Wall Section & 2X2X1

8 Tube Wall Support

Wall Assembly

Front View

4" X 2" X 3 16"

Corner Supports

2 X

X .06

5 T ub e F ra me

16 GA HRS Door Skins

Non Fire Rated Door Detail

Rear View

CHEM-STOR

14 GA HRS

Door Jamb Sides and Header

Two Each 10 GA Bent Roof Joists Seamed together at Open Ends for Side Supports

4" X 2" X 3 16" Corner

Supp. Typ. at 4 Corners

2" X 2" X 18"" Wall Supports - 2'-0" O.C Max.

4" X 3" X 38" Angle with 78" Hole Typ. at 4 Corners

16GA HRS Bent Wall Panel

Corner Detail

10 GA HRS Floor Sheets Continuously Welded at All Seams Leak Tested

Structural Channel Front, Back and Sides

Interlocking Wall Panel All Units 16 Gauge HRS - Bent

2 X 2 X 18" Tube - 2' OC Max Spacing

1'-11

1"

A p p r o x

Wall Section Detail Double Wall Insulated

2" X 2" X 18" Tube

1'-11

2" O.C Max

16GA Bent Wall Panels

4" X 2" X 1/8" Door Header

Left Side View

CHEM-STOR

DOT Placard

C4X5.4 Floor Support 4X3X1

2 Angle

C6X8.2 Base Side

14 GA HRS Fully Welded Roof

Right Side View

R11 Insulation 20GA INT Sheet

4" X 2" X 1/8" Door Header

CHEM-STOR

DOT Placard

4" X 2" X 1/8" Door Header

CHEM-STOR

DOT Placard

Front Right

Back Right

Front Left

Back Left

Wall Corners

Right 16GA Front Panel

Left 16GA Front Panel 2" X 2" X 18"" Wall Support

Center 16GA Front Panels (2 Each)

2 X

X 1 8"

Tu be

2 X

X 1 8"

Tu be

2H R

Fir e R ate d S ep ar ati on

W all

2H R

Fir e R ate d S ep ar ati on

W all

Exp Proof Exhaust FanExp Proof Exhaust FanExp Proof Exhaust Fan 2H

R Fir e R ate d S ep ar ati on W all

2H R

Fir e R ate d S ep ar ati on

W all

Welded 10GA Grating Support Angle

Welded 10GA Grating Support Angle

Welded 10GA Grating Support Angle

Welded 10GA Grating Support Angle

Wall and Corner Supports Installed to the Inside Edge of Structural Channel

Light & Variable Speed Control Fan Switch

Light & Variable Speed Control Fan Switch

Light & Variable Speed Control Fan Switch

12X12 Air Vent

12X12 Air Vent

12X12 Air Vent

NEMA 3R Load Center 120/240V Single Phase100 Amp

Gauley Storage Unit Monongahela National Forest Service

Seismic Tie Down Pads @ 4 Corners Exterior Ground Connection

DOT Placard

Layout View

No.

Revisions

Sheet Title

Drawn By

Checked By

Date

Scale

Job Number

Revision

Sheet Number

Approved By

ByDate Item

Equipment Layout View

KMS L1

NONE

8/4/2022

Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com

Forklift Pockets

10 Gauge - 6" Deep Secondary Containment Area

CHEM-STOR

10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.

6'-0" Wide X 6'-8" High

Front View

Double Wall Steel Storage Building. Insulated, Walls, Roof and Doors, R11. 10 Gauge Floor. Exterior and Interior Heavy Gauge Steel Sheets. 34'6" X 8'0" X 8'4" High Exterior. Standard Equipment: Two Part Chemical Resistant Paint Interior and Exterior. 12" X 12" Air Vents for natural ventilation. Exterior Ground Connection. Galvanized Steel Grate Flooring with removable Galvanized Grating Supports.

Epoxy Coated 6" Deep Secondary Containment Area. Forklift Pockets.

3 Each Insulated Double Door Sets with 3PT Locking Mechanism with Padlock Hasp and Interior Safety Release. Seismic Tie Down Pads.

1 Each Explosion Proof LED Fixture in Each Room. Weather Proof Switches Mounted on the Exterior Right Hand Wall.

1 Each Explosion Proof Exhaust Fan in Each Room. Weather Proof Variable Speed Control Switches Mounted on the exterior right hand wall.

1 Each Explosion Proof 12,000 BTU Heater in 2 Rooms. 240 Volt 3 Rows of Shelving on Back Wall. 16" Deep X 2" Lip Galvanized Steel.

DOT Placard

CHEM-STOR

DOT Placard

CHEM-STOR

2H R

Fir e R ate d S ep ar ati on

W all

2H R

Fir e R ate d S ep ar ati on

W all

10 Gauge - 6" Deep Secondary Containment Area

Rear View

2H R

Fir e R ate d S ep ar ati on

W all

2H R

Fir e R ate d S ep ar ati on

W all

6'-0" Wide X 6'-8" High6'-0" Wide X 6'-8" High

10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.

10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.

Right Side View

Left Side View

12X12 Air Vent12X12 Air Vent 12X12 Air Vent

Exp Proof Exhaust Fan

Class 1 Div 1 & 2 Heater 12,000 BTU 240V

C1D1 LED Light Fixture

Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal

Exp Proof Exhaust FanExp Proof Exhaust Fan

C1D1 LED Light FixtureC1D1 LED Light Fixture

Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal

Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal

2H R

Fir e R ate d S ep ar ati on

W all

2H R

Fir e R ate d S ep ar ati on

W all NEMA 3R Load

Center 120/240V Single Phase100 Amp

NEMA 3R

Light & Variable Speed Control Fan Switch

Class 1 Div 1 & 2 Heater 12,000 BTU 240V

NEMA 3R

Light & Variable Speed Control Fan Switch

NEMA 3R

Light & Variable Speed Control Fan Switch

Gauley Storage Unit Monongahela National Forest Service

Hazardous Location Exhaust Fan Parts Submittal

1/4 HP Hazardous Location Motor, Continuous Duty, Capacitor-Start, 1725 Nameplate RPM, 115/208-230

Voltage, Frame 56, Class 1 Div 1 & 2 Groups E, F & G

UL Listed (E12044)

Aluminum Fan Blade Propeller, 12 In, 5/8 Bore, 2320 CFM

20 Gauge Galvanized Steel Fan Guard, 16-1/8"H x 16-

1/8"W x 15" Depth

12" Galvanized Steel Exhaust Fan Venturi Frame, 16"H x 16"W x 8-

3/4" Max. Depth

Wall Mount Only:

12" Backdraft Damper / Wall

Shutter

EPL-LP-12-LED

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 Product ID: 147703

Please see last page for supporting documentation for this product(certificates, CAD files & drawings, IES files, wiring diagrams, etc).

EPL-LP-12-LED Explosion Proof Low Profile LED Ratings/Approvals Lamp Type: LED Class I, Division 1 , Groups C and D Listing: United States, Canada Class I, Division 2, Groups A, B, C, D Dimensions: 18"L x 5"W x 3"H Class II, Divisions 1 & 2 Groups E, F and G Weight: 4.75 lbs Class III, Divisions 1 & 2 Voltage: Universal 100-277V AC, 50/60Hz or 12-24V DC T6 Temperature Rating Total Watts: 26W NRTL Certified to UL 844 Ed. 13 Lumens: 3,380 NRTL Certified to UL 1598 Luminous Efficacy: 130 Lm/W Certified to C22.2 No. 137 Rev 2014 Lamp Life: 60,000+ Hours Certified to C22.2 No. 250.0 Color Temp: 5000K, 4500K or 3000K Paint Spray Booth Approved Color Rendering Index: >75 CRI Factory Sealed Light Fixture Beam Angle: 100° Horizontal, 140° Vertical Lighting Configuration: Wide Flood Pattern

Power Efficiency: >95% Power Factor: 0.992 Amperage: 0.44A @ 120V, 0.22 @ 240V, 0.19 @ 277V Ambient Operating Temp Range: -50°C to +65°C Operating Temp Rating: T6 Special Orders- Requirements Housing Material: Copper Free Cast Aluminum Contact us for special requirements Lens Material: Hardened Borosilicate Glass Toll Free: 1-800-369-6671 Mounting: 3/4" Pendant & Swivel Mount - Both Ship w/ Fixture Intl: 1-214-616-6180 Wiring: Terminal Strips Fax: 1-903-498-3364

Wiring Hub: 3/4" NPT E-mail: sales@larsonelectronics.com

The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof Light Fixture that provides operators with a powerful and energy efficient alternative to traditional hazardous location luminaries. LED technology and compact design makes this lamp an excellent replacement upgrade option for bulky and high maintenance cost older fixtures. This explosion proof LED light has a T6 temperature rating and carries a paint spray booth, and is approved for use in United States, Canada, and Mexico markets. It is ideal for applications such as paint booths, oil rigs, offshore applications, petrochemical, manufacturing, chemical storage, water treatment centers, and food processing plants where a where flammable gases, vapors, or dusts exist or stand the potential to exist. The EPL-LP- 12-LED is equipped with terminal strips for wiring.

Larson Electronics LLC 9419 E US HWY 175, Kemp, TX 75143 Phone: 800.369.6671 www.LarsonElectronics.com Email: sales@LarsonElectronics.com

Fax: 903.498.3364 mailto:sales@larsonelectronics.com basic Rectangle basic Image basic Rectangle

Hazardous Location WALL CONVECTOR heaters Electric wall mounted convectors designed for hazardous location areas requiring ratings of:

Class I, Group B, C, & D, Division 1 & 2

FEATURES

benefits

Application solutions

FEP-18/FEP-36

FEP-76

EPET

HLT

• ETL C/US listed for indoor commercial & industrial heating applications for hazardous location rated areas

• Rated for Class I, Group B, C, & D, Division 1 & 2, NEMA-4 washdown rated and temperature rating of 536ºF (280ºC)

• Housing material contains a heavy-duty 16-gauge steel slope top design with gray epoxy textured powder coated finish

• Units equipped with NEMA 4 cast aluminum terminal enclosure located on the left side of the heater

• Units designed for bottom air in and front out airflow distribution of heat output

• Stainless steel cartridge element inserted into aluminum finned copper tubular sheath

• Minimum mounting height is 9" clearance from a floor surface for all units

• Heaters are designed to mount directly a wall surface using the supplied brackets

• 1-Phase, 50/60-Hz, 120, 208, 240, & 480-Volt electrical connections (480-Volt models are rated for 3-phase)

• Control compartment is located on the side of the housing for easier access of installation and service

• Supplied wall bracket allows the customer to install these heaters in a horizontal operating position on all types of wall surfaces

• Heaters have a compact construction designed to operate in corrosive and hazardous location rated environments

• Heaters are constructed for use in areas that require washing or hosing of equipment in dirty or dusty environments in hazardous location areas.

• Heaters are ideal for water treatment facilities, industrial and maintenance locations, chemical storage and many more.

Optional Accessory THERMOSTATs - line voltage

GRAINGER MODEL # MFG MODEL # WATTS BTUs VOLTS AMPS PHASE WT.

(lbs.)

DIMENSIONS (in.)

L D H

49CT92 FEP-1812-1RA

1,800 6,143

120 15.0

50 34.0 8.3 17.949CT93 FEP-1820-1RA 208 8.7

49CT94 FEP-1824-1RA 240 7.5

49CT95 FEP-3620-1RA

3,600 12,286 208 17.3

64 34.0 8.3 17.949CT96 FEP-3624-1RA 240 15.0

49CT97 FEP-3648-3RA 480 4.3 3

49CT98 FEP-7624-1RA 7,600 25,938 240 31.7 1 85 58.0 8.3 17.949CT99 FEP-7648-3RA 480 9.2 3

GRAINGER

MODEL #

MFG

MODEL # ITEM DESCRIPTION MAX

AMP VOLTS FOR USE

WITH

WT.

(lbs.)

4PU50 EPETD8DJ Wall Mounting Thermostat

Line Voltage DPDT Stat, 50-90º F Temp Range

Amps

24-277

VAC

All FEP Heaters (49CT92 thru

49CT99)

6GVX9 HLT-2 12

1/4" x 20 x 3/4" Bolt with Nut, Lockwasher & Washer

Adjustable Shelving 16” Deep X 2” Lip on All edges. 16 GA

Galvanized Steel

Unistrut Stitch welded or Bolted to Structural Member

3/8" Spring Nut

3/8" x 1" Hex Head Nut

1 5/8" x 1 5/8" Strut

Shelving Bracket

SHELVING INSTALLATION DETAIL

Sample Photo Side & Back Wall Shown

IDEAL Environmental Products

Hazardous Material and Portable Solar Powered Storage Buildings

Mail: 1850 So. 10th Street Suite 30, San Jose, CA 95112 Shipping: 1725 W. Pacheco Blvd., Los Banos, CA 93635 Toll Free 800-844-6998 Website: www.chem-stor.com Email: ideal.sales@chem-stor.com

CHEM-STOR

http://www.chem-stor.com/