Att. 6 Shop Drawing & Submittal Sheets 337 - 34X8-NCDW22001 220815.pdf
PDF 1 MB Posted
- Solicitation number
- 12445522Q0162
- Issued by
-
Department of Agriculture Forest Service
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
No.
Revisions
Sheet Title
Drawn By
Checked By
Date
Scale
Job Number
Revision
Sheet Number
Approved By
ByDate Item
General Notes and Details
KMS D0
NONE
8/12/2022
Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com
Structural Design Loads:
Live Loads:
Roof: 40 PSF (Snow) Grated Floor: 250 PSF Base: 500 PSF Wall, Roof & Floor: 100 PSF
Dead Loads:
Roof: 20 PSF Floor: 85 PSF Wall: 20 PSF
Wind Design Data: (Per IBC 2018) Risk Category II Basic Wind Speed - 150 Mph, 3 sec gust. Exposure Category - C
Seismic Design Data: Worst case Per IBC 2018
A) Dimensions - 34'6" X 8'2" X 8'-4" High.Exterior.
B) Spill Containment - Internal spill containment is a major design feature of the storage container. When filled with 55 gallon drums stored upright and unstacked, the container will contain a minimum of the total leakage from one-quarter (25%) of the drums. Spill Containment is 6" Deep.
C) Floor - The floor of the container is constructed of 10 gauge steel and incorporates a false floor system to prevent the release of hazardous liquids and solids if they are discharged from a primary container.
D) Walls & Roof - The walls and roof are fabricated using 16 GA Bent Wall Panels and Structural Wall Tubes.
E) Doors - Non Combustible Steel Units are Supplied with 16 Gauge Doors. The doors have a 3 pt. Locking Mechanism with a Padlock Hasp, Interior Safety Override and Door Hold Open.
F) Ventilation - The container is equipped with vents for natural ventilation.
G) Grounding - The container is equipped with one exterior static grounding connection.
H) Seismic Tie Down - The container is equipped with provisions for securing the building to the ground per seismic Zone 4 regulations.
Workmanship:
A) Steel Fabrication - The steel used to fabricate the container is free from kinks, and sharp bends. The manufacturing process does not reduce the strength of the steel to a value less than intended by the design. Each manufacturing process is done neatly and accurately, and all bends are made by controlled means to insure uniformity of size and shape.
B) Welding - The welding procedures employed are in accordance with the filler metal specifications of the American Welding Society and in cooperation with the ASTM. All welds are of sufficient size and shape to develop the full design strength of the parts connected by the welds. These welds transmit the imposed stresses without permanent deformation or failure when subject to proof of storage loads.
C) Painting - After a thorough cleaning process the exterior and interior of the container are painted with a self-priming chemical resistant durable urethane paint.
DESIGN DATA
INSTALLATION & END USER RESPONSIBILITIES
Gauley Storage Unit Monongahela National Forest Service Order 12444322F087 Job (337)34X8-NCDW22001
End User Responsibilities and Installation Instructions
End user is responsible for offloading, installation, permitting and proper use of the Building as required by their Local Jurisdiction. The Manufacturer is not responsible for any damage to people or property due to the misuse or in proper installation of its products. End user is responsible for determining proper storage and allowable quantities of hazardous materials used and stored within the building as well as proper classification of electrical equipment used within the structure. The Manufacturer is not responsible for any damage resulting from offloading or installation.
Offload Instructions: Building Weight is Approximately 17,000# Crane Rigging:
Forklift Pockets are Provided. All must be used to achieve a balanced lift. Crane Capacity is to be determined by the equipment handler based on the weight of the unit, type of lift and site conditions. Slings are to be placed through the forklift pockets provided. Buildings are to be supported at the middle and both end pockets. Spreader Bars are to be used to protect exterior mounted equipment.
Forklift Procedure:
Forklift Pockets are Provided. All must be used to achieve a balanced lift. Forklift Pockets must be used when lifting the buildings with a forklift. Any attempts to lift the buildings at other locations may result in damage to the floor of the unit. Appropriate Capacity is to be determined by the equipment handler based on the weight of the unit, site conditions and length of forks.
Installation Instructions/End User Responsibilities: Aerosol Touch up Paint is shipped inside the building.
1. Acquire all proper permitting for the use and installation of the unit as required by the local jurisdiction.
2. Contract with a Licensed Electrician to provide power to the load center. (If Provided)
3. Provide Level Surface Capable of Supporting the Weight of the Unit and contents/equipment to be stored.
4. Any dirt or water which enters the building during shipment must be clean and dry prior to using the building. Grating and supports are removable for clean-up of the secondary containment area.
5. Seal all holes made in the buildings to close openings for shipping with the Caulking Provided. (if applicable)
6. Inspect Building for Loose Grating Clips. Shipping and Handling may cause the Grating clips to become loose. Grating must be checked and secured prior to use of the building.
7. Inspect Building for Gaps along the interior of the forklift pockets and other interior and exterior seams. All seams are sealed with Caulking at the Factory as Required prior to paint and upon final shipping inspection. Gaps in the caulking may result from Transportation and Handling. All gaps must be sealed to prevent moisture intrusion prior to using the building.
8. Touch up any paint damaged during transportation, offloading or installation of the building to protect steel surfaces from rusting.
9. Dry Chemical Fire Suppression System: (If provided) The dry chemical fire extinguishing system is NOT armed during shipment. This system must be armed by a qualified technician. Disarm the system before relocation and arm it when relocation is complete. Fusible links should be replaced every six (6) months.
10. Anchor Building to foundation as required by local jurisdiction. Anchor Pads are provided as part of the building at all 4 corners. Any Engineering required for proper anchoring is the responsibility of the end user.
11.Your Chemical Storage Locker containment sump was leak tested at the factory. It is possible that improper handling during shipping could cause a fracture or rupture to the sump. It is strongly recommended that the locker be leveled, the sump filled with water and allowed to stand overnight. Any leaks should then be readily apparent. It is also recommended that this test be made each time the locker is relocated or after a spill clean-up. The booklet located inside your unit provides an inspection log. Sump inspections (at least every 72 hours) and all maintenance activity should be recorded.
12.Explosion Venting: (If provided) The explosion relief panel limiting chains have been secured for shipping. Remove tie downs (see tags on relief panels) before storing chemicals. If a roof mounted explosion relief cap is provided, it should be exercised monthly (with the application of a light oil if necessary) to keep the hinges free of rust and operating smoothly.
13.Forced Ventilation: (If provided) The intake and discharge ducts on the forced air circulation fan should be checked daily for obstructions, and the fan and damper hinge lubricated biannually.
4 X 3 X 38" Angle 4" X 3" X 38" Angle with 78" Hole Typ. at 4 Corners
SHEET INDEX
SHEET
NUMBER
SHEET TITLE
D0 GENERAL NOTES
D1 BASE AND ROOF ASSEMBLY
D2 WALL ASSEMBLY - DOUBLE WALL STEE; INSULATED
L1 EQUIPMENT LAYOUT VIEW
INTELLECTUAL PROPERTY
ANCHORING DETAILS
ELECTRICAL REQUIREMENTS
10 GA Bent Back Roof Supp.
G
A Be nt Ro of Jo ist
3" 3"
14 GA HRS Exterior Sheet Continuously Welded - Water Tight
10 GA 4 1/2" to 2 1/2" Bent Tapered Roof Support Front & Back. 4 14" to 2 14" Bent Tapered Roof Joint
2'-0" O.C.
2'
Side View 6" Deep Containment
C4X5.4 Floor Support 4X3X1
2 Angle
C6X8.2 Base Side
Roof Framing and Plan
3" 3"
3 8
Front Back
10 GA Bent Front & Back Support
10 GA Bent Side & Interior Roof Joists
Roof Supports
Roof Section Detail
2 Roof Joists at
Each End
Roof Joists Fit Inside
Front & Rear Roof
Supports
14 GA HRS Welded
Continously at all
Seams Water Tight
10 GA Bent Roof Joist
14 GA HRS
10 GA Bent
Roof Support
Front & Back
14 GA HRS Continuously Welded Water Tight Roof Seams Centered on Bent Supports
10 GA Bent Front Roof Supp.
No.
Revisions
Sheet Title
Drawn By
Checked By
Date
Scale
Job Number
Revision
Sheet Number
Approved By
ByDate Item
Base and Roof Assembly
KMS D1
NONE
8/12/2022
Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com
C6 X 8.2 Base Front and Rear
4X3X1 2 Angle
10GA
Floor Plate 8X4X 3
16" Forklift Pockets C4X5.4 Base Supports
10GA
Sump Plate
8X 4X
3 16 " F or kli ft P oc ke ts
Be low
C4 X5
.4 Ba se S up po rts B elo w
C6 X8
.2 Ba se S ide s
Base Assembly
4 X 3 X 12 Angle
C6 X 8.2 Base Sides
Removable Grating Support 12GA Galv
C4 X 5.4 Base Supports
10GA
Floor Plate
For welds not shown notes,
1. All Welds to be continuous at end connection all base and corner supports.
2. All Fillets weld to be the same thickness as the materials
3. Continuous welds at sump leak test
4. Fillet weld 3
16 to be 2" on 14" at corners supports both ends
5. 14 GA and 16 GA sheet metal welds @ wall supports to be 18" fillets 1" on 18" fillet welds each side of support minimum distortion on all wall panels and base.
6. Exterior sheet welds to be 18" filets 1" on 12" at Header on Exterior.
7. Exterior sheet welds to be continuous at Base on Interior.
6" Base Detail
Galvanized Steel Grating
CHEM-STOR
10 GA HRS Floor Sheets Continuously Welded at All Seams Leak Tested
10GA 72 X 96
Sump Plate
10GA 72 X 96
Sump Plate
10GA 72 X 96
Sump Plate
10GA 72 X 96
Sump Plate
10GA 72 X 96
Sump Plate
10GA 48 X 96
Sump Plate
14GA 48 X 96
Roof Sheet
14GA 24 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
14GA 48 X 96
Roof Sheet
R11 Insulation 20GA INT Sheet
Gauley Storage Unit Monongahela National Forest Service Order 12444322F087 Job (337)34X8-NCDW22001
No.
Revisions
Sheet Title
Drawn By
Checked By
Date
Scale
Job Number
Revision
Sheet Number
Approved By
ByDate Item
KMS D2
NONE
8/13/2022
TBD
Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com
Exterior Wall 14 GA Bent Corner with 16GA Bent Wall Section & 2X2X1
8 Tube Wall Support
Wall Assembly
Front View
4" X 2" X 3 16"
Corner Supports
2 X
X .06
5 T ub e F ra me
16 GA HRS Door Skins
Non Fire Rated Door Detail
Rear View
CHEM-STOR
14 GA HRS
Door Jamb Sides and Header
Two Each 10 GA Bent Roof Joists Seamed together at Open Ends for Side Supports
4" X 2" X 3 16" Corner
Supp. Typ. at 4 Corners
2" X 2" X 18"" Wall Supports - 2'-0" O.C Max.
4" X 3" X 38" Angle with 78" Hole Typ. at 4 Corners
16GA HRS Bent Wall Panel
Corner Detail
10 GA HRS Floor Sheets Continuously Welded at All Seams Leak Tested
Structural Channel Front, Back and Sides
Interlocking Wall Panel All Units 16 Gauge HRS - Bent
2 X 2 X 18" Tube - 2' OC Max Spacing
1'-11
1"
A p p r o x
Wall Section Detail Double Wall Insulated
2" X 2" X 18" Tube
1'-11
2" O.C Max
16GA Bent Wall Panels
4" X 2" X 1/8" Door Header
Left Side View
CHEM-STOR
DOT Placard
C4X5.4 Floor Support 4X3X1
2 Angle
C6X8.2 Base Side
14 GA HRS Fully Welded Roof
Right Side View
R11 Insulation 20GA INT Sheet
4" X 2" X 1/8" Door Header
CHEM-STOR
DOT Placard
4" X 2" X 1/8" Door Header
CHEM-STOR
DOT Placard
Front Right
Back Right
Front Left
Back Left
Wall Corners
Right 16GA Front Panel
Left 16GA Front Panel 2" X 2" X 18"" Wall Support
Center 16GA Front Panels (2 Each)
2 X
X 1 8"
Tu be
2 X
X 1 8"
Tu be
2H R
Fir e R ate d S ep ar ati on
W all
2H R
Fir e R ate d S ep ar ati on
W all
Exp Proof Exhaust FanExp Proof Exhaust FanExp Proof Exhaust Fan 2H
R Fir e R ate d S ep ar ati on W all
2H R
Fir e R ate d S ep ar ati on
W all
Welded 10GA Grating Support Angle
Welded 10GA Grating Support Angle
Welded 10GA Grating Support Angle
Welded 10GA Grating Support Angle
Wall and Corner Supports Installed to the Inside Edge of Structural Channel
Light & Variable Speed Control Fan Switch
Light & Variable Speed Control Fan Switch
Light & Variable Speed Control Fan Switch
12X12 Air Vent
12X12 Air Vent
12X12 Air Vent
NEMA 3R Load Center 120/240V Single Phase100 Amp
Gauley Storage Unit Monongahela National Forest Service
Seismic Tie Down Pads @ 4 Corners Exterior Ground Connection
DOT Placard
Layout View
No.
Revisions
Sheet Title
Drawn By
Checked By
Date
Scale
Job Number
Revision
Sheet Number
Approved By
ByDate Item
Equipment Layout View
KMS L1
NONE
8/4/2022
Ideal Environmental Products 1725 W. Pacheco Blvd., Los Banos, CA 93635 800-844-6998 www.chem-stor.com
Forklift Pockets
10 Gauge - 6" Deep Secondary Containment Area
CHEM-STOR
10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.
6'-0" Wide X 6'-8" High
Front View
Double Wall Steel Storage Building. Insulated, Walls, Roof and Doors, R11. 10 Gauge Floor. Exterior and Interior Heavy Gauge Steel Sheets. 34'6" X 8'0" X 8'4" High Exterior. Standard Equipment: Two Part Chemical Resistant Paint Interior and Exterior. 12" X 12" Air Vents for natural ventilation. Exterior Ground Connection. Galvanized Steel Grate Flooring with removable Galvanized Grating Supports.
Epoxy Coated 6" Deep Secondary Containment Area. Forklift Pockets.
3 Each Insulated Double Door Sets with 3PT Locking Mechanism with Padlock Hasp and Interior Safety Release. Seismic Tie Down Pads.
1 Each Explosion Proof LED Fixture in Each Room. Weather Proof Switches Mounted on the Exterior Right Hand Wall.
1 Each Explosion Proof Exhaust Fan in Each Room. Weather Proof Variable Speed Control Switches Mounted on the exterior right hand wall.
1 Each Explosion Proof 12,000 BTU Heater in 2 Rooms. 240 Volt 3 Rows of Shelving on Back Wall. 16" Deep X 2" Lip Galvanized Steel.
DOT Placard
CHEM-STOR
DOT Placard
CHEM-STOR
2H R
Fir e R ate d S ep ar ati on
W all
2H R
Fir e R ate d S ep ar ati on
W all
10 Gauge - 6" Deep Secondary Containment Area
Rear View
2H R
Fir e R ate d S ep ar ati on
W all
2H R
Fir e R ate d S ep ar ati on
W all
6'-0" Wide X 6'-8" High6'-0" Wide X 6'-8" High
10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.
10 Gauge 6" Deep Secondary Containment Area with Galvanized Grating rated at 250 psf.
Right Side View
Left Side View
12X12 Air Vent12X12 Air Vent 12X12 Air Vent
Exp Proof Exhaust Fan
Class 1 Div 1 & 2 Heater 12,000 BTU 240V
C1D1 LED Light Fixture
Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal
Exp Proof Exhaust FanExp Proof Exhaust Fan
C1D1 LED Light FixtureC1D1 LED Light Fixture
Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal
Adjustable Shelving Galvanized Steel 16" Deep X 2" Lip - 3 Rows on Back Wal
2H R
Fir e R ate d S ep ar ati on
W all
2H R
Fir e R ate d S ep ar ati on
W all NEMA 3R Load
Center 120/240V Single Phase100 Amp
NEMA 3R
Light & Variable Speed Control Fan Switch
Class 1 Div 1 & 2 Heater 12,000 BTU 240V
NEMA 3R
Light & Variable Speed Control Fan Switch
NEMA 3R
Light & Variable Speed Control Fan Switch
Gauley Storage Unit Monongahela National Forest Service
Hazardous Location Exhaust Fan Parts Submittal
1/4 HP Hazardous Location Motor, Continuous Duty, Capacitor-Start, 1725 Nameplate RPM, 115/208-230
Voltage, Frame 56, Class 1 Div 1 & 2 Groups E, F & G
UL Listed (E12044)
Aluminum Fan Blade Propeller, 12 In, 5/8 Bore, 2320 CFM
20 Gauge Galvanized Steel Fan Guard, 16-1/8"H x 16-
1/8"W x 15" Depth
12" Galvanized Steel Exhaust Fan Venturi Frame, 16"H x 16"W x 8-
3/4" Max. Depth
Wall Mount Only:
12" Backdraft Damper / Wall
Shutter
EPL-LP-12-LED
26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 Product ID: 147703
Please see last page for supporting documentation for this product(certificates, CAD files & drawings, IES files, wiring diagrams, etc).
EPL-LP-12-LED Explosion Proof Low Profile LED Ratings/Approvals Lamp Type: LED Class I, Division 1 , Groups C and D Listing: United States, Canada Class I, Division 2, Groups A, B, C, D Dimensions: 18"L x 5"W x 3"H Class II, Divisions 1 & 2 Groups E, F and G Weight: 4.75 lbs Class III, Divisions 1 & 2 Voltage: Universal 100-277V AC, 50/60Hz or 12-24V DC T6 Temperature Rating Total Watts: 26W NRTL Certified to UL 844 Ed. 13 Lumens: 3,380 NRTL Certified to UL 1598 Luminous Efficacy: 130 Lm/W Certified to C22.2 No. 137 Rev 2014 Lamp Life: 60,000+ Hours Certified to C22.2 No. 250.0 Color Temp: 5000K, 4500K or 3000K Paint Spray Booth Approved Color Rendering Index: >75 CRI Factory Sealed Light Fixture Beam Angle: 100° Horizontal, 140° Vertical Lighting Configuration: Wide Flood Pattern
Power Efficiency: >95% Power Factor: 0.992 Amperage: 0.44A @ 120V, 0.22 @ 240V, 0.19 @ 277V Ambient Operating Temp Range: -50°C to +65°C Operating Temp Rating: T6 Special Orders- Requirements Housing Material: Copper Free Cast Aluminum Contact us for special requirements Lens Material: Hardened Borosilicate Glass Toll Free: 1-800-369-6671 Mounting: 3/4" Pendant & Swivel Mount - Both Ship w/ Fixture Intl: 1-214-616-6180 Wiring: Terminal Strips Fax: 1-903-498-3364
Wiring Hub: 3/4" NPT E-mail: sales@larsonelectronics.com
The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof Light Fixture that provides operators with a powerful and energy efficient alternative to traditional hazardous location luminaries. LED technology and compact design makes this lamp an excellent replacement upgrade option for bulky and high maintenance cost older fixtures. This explosion proof LED light has a T6 temperature rating and carries a paint spray booth, and is approved for use in United States, Canada, and Mexico markets. It is ideal for applications such as paint booths, oil rigs, offshore applications, petrochemical, manufacturing, chemical storage, water treatment centers, and food processing plants where a where flammable gases, vapors, or dusts exist or stand the potential to exist. The EPL-LP- 12-LED is equipped with terminal strips for wiring.
Larson Electronics LLC 9419 E US HWY 175, Kemp, TX 75143 Phone: 800.369.6671 www.LarsonElectronics.com Email: sales@LarsonElectronics.com
Fax: 903.498.3364 mailto:sales@larsonelectronics.com basic Rectangle basic Image basic Rectangle
Hazardous Location WALL CONVECTOR heaters Electric wall mounted convectors designed for hazardous location areas requiring ratings of:
Class I, Group B, C, & D, Division 1 & 2
FEATURES
benefits
Application solutions
FEP-18/FEP-36
FEP-76
EPET
HLT
• ETL C/US listed for indoor commercial & industrial heating applications for hazardous location rated areas
• Rated for Class I, Group B, C, & D, Division 1 & 2, NEMA-4 washdown rated and temperature rating of 536ºF (280ºC)
• Housing material contains a heavy-duty 16-gauge steel slope top design with gray epoxy textured powder coated finish
• Units equipped with NEMA 4 cast aluminum terminal enclosure located on the left side of the heater
• Units designed for bottom air in and front out airflow distribution of heat output
• Stainless steel cartridge element inserted into aluminum finned copper tubular sheath
• Minimum mounting height is 9" clearance from a floor surface for all units
• Heaters are designed to mount directly a wall surface using the supplied brackets
• 1-Phase, 50/60-Hz, 120, 208, 240, & 480-Volt electrical connections (480-Volt models are rated for 3-phase)
• Control compartment is located on the side of the housing for easier access of installation and service
• Supplied wall bracket allows the customer to install these heaters in a horizontal operating position on all types of wall surfaces
• Heaters have a compact construction designed to operate in corrosive and hazardous location rated environments
• Heaters are constructed for use in areas that require washing or hosing of equipment in dirty or dusty environments in hazardous location areas.
• Heaters are ideal for water treatment facilities, industrial and maintenance locations, chemical storage and many more.
Optional Accessory THERMOSTATs - line voltage
GRAINGER MODEL # MFG MODEL # WATTS BTUs VOLTS AMPS PHASE WT.
(lbs.)
DIMENSIONS (in.)
L D H
49CT92 FEP-1812-1RA
1,800 6,143
120 15.0
50 34.0 8.3 17.949CT93 FEP-1820-1RA 208 8.7
49CT94 FEP-1824-1RA 240 7.5
49CT95 FEP-3620-1RA
3,600 12,286 208 17.3
64 34.0 8.3 17.949CT96 FEP-3624-1RA 240 15.0
49CT97 FEP-3648-3RA 480 4.3 3
49CT98 FEP-7624-1RA 7,600 25,938 240 31.7 1 85 58.0 8.3 17.949CT99 FEP-7648-3RA 480 9.2 3
GRAINGER
MODEL #
MFG
MODEL # ITEM DESCRIPTION MAX
AMP VOLTS FOR USE
WITH
WT.
(lbs.)
4PU50 EPETD8DJ Wall Mounting Thermostat
Line Voltage DPDT Stat, 50-90º F Temp Range
Amps
24-277
VAC
All FEP Heaters (49CT92 thru
49CT99)
6GVX9 HLT-2 12
1/4" x 20 x 3/4" Bolt with Nut, Lockwasher & Washer
Adjustable Shelving 16” Deep X 2” Lip on All edges. 16 GA
Galvanized Steel
Unistrut Stitch welded or Bolted to Structural Member
3/8" Spring Nut
3/8" x 1" Hex Head Nut
1 5/8" x 1 5/8" Strut
Shelving Bracket
SHELVING INSTALLATION DETAIL
Sample Photo Side & Back Wall Shown
IDEAL Environmental Products
Hazardous Material and Portable Solar Powered Storage Buildings
Mail: 1850 So. 10th Street Suite 30, San Jose, CA 95112 Shipping: 1725 W. Pacheco Blvd., Los Banos, CA 93635 Toll Free 800-844-6998 Website: www.chem-stor.com Email: ideal.sales@chem-stor.com
CHEM-STOR
http://www.chem-stor.com/