1258 Boiling Springs Road • Spartanburg, SC 29303 • Phone 864‐541‐8736 / Fax 864‐541‐8776 www.crossroadsenv.net
ASBESTOS INSPECTION REPORT
FOR
CLIENT
Francis Marion & Sumter National Forest
4931 Broad River Road Abbeville, SC 29620
SITE LOCATION
Witherbee Site
2355, 2367, 2381 & 2397 Witherbee Road Cordesville, South Carolina
INSPECTION DATE: April 10, 2020 REPORT DATE: April 17, 2020
INSPECTOR
Kay H. Horton – SC‐DHEC License #ASB‐23394
(864) 541‐8736
For
Crossroads Environmental, LLC 1258 Boiling Springs Road
Spartanburg, South Carolina 29303
(864) 541‐8736
CRE Project # 18039‐IN
TABLE OF CONTENTS
INSPECTION REPORT/LETTER
BACKGROUND INFORMATION
BUILDING/AREA DESCRIPTION
INSPECTION STRATEGY/SAMPLING PROTOCOL
RESULTS
RELEVANT REGULATORY REQUIREMENTS/RECOMMENDATIONS
CLOSING STATEMENTS AND LIMITATIONS
ATTACHMENTS
ATTACHMENT I: ASBESTOS SUMMARY TABLE
ATTACHMENT II: LABORATORY REPORT
ATTACHMENT III: BUILDING/AREA SKETCH
ATTACHMENT IV: INSPECTOR’S LICENSE/ACCREDITATION
April 17, 2020
Mr. Mike Alcorn Forest Service Francis Marion & Sumter National Forest Service 4931 Broad River Road Columbia, SC 29212
Re: Asbestos Inspection Report 2355, 2367, 2381 & 2397 Witherbee Road
Cordesville, South Carolina CRE Project Number: 18039‐IN
Dear Mr. Alcorn:
Crossroads Environmental, LLC (CRE) completed an asbestos inspection of the Witherbee Site, located on Witherbee Road in Cordesville, SC on April 10, 2020. The inspection was performed by a SC‐DHEC Licensed Asbestos Inspector, and in accordance with South Carolina Department of Health and Environmental Control (SC‐DHEC) and Environmental Protection Agency (EPA) Requirements. A detailed summary table of the sampling is included in Attachment I; however, this report should be read in its entirety.
Building(s) Description/Scope of Work
The Witherbee Site, part of Francis Marion & Sumter National Forest, consists of four (4) houses, an associated storage building for each house, and one central well house. All structures are scheduled for demolition. Comprehensive asbestos inspections of the houses were performed by Trident Environmental in 2014, but the storage buildings and well house were excluded.
In accordance with SC‐DHEC’s Regulation 61‐86.1, Standards of Performance for Asbestos Projects (effective May 27, 2011), “to be acceptable, a building inspection shall have been performed no earlier than three years prior to the renovation of demolition, or if more than three years have elapsed since the most recent inspection, the previous inspection shall be confirmed and verified by a person licensed as a building inspector”.
CRE performed the required confirmation/verification of the inspection report provided by Trident Environmental. Additionally, comprehensive asbestos inspections of the storage buildings and well house were performed.
Asbestos Inspection Report April 17, 2020 Witherbee Site Page 2 of 4 Project Number: 18039‐IN
The structures included are as follows:
Dwelling Building 602: This structure is a vacant single‐family residence located at a 2355 Witherbee Road, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.
Storage Building 652: This building is a 7’x12’ wooden storage building, located behind Building 602, which has wood siding, concrete floor, and a shingled roof. The building has metal framed windows. No suspect window glaze or caulk were identified in association with the windows.
Dwelling Building 603: This structure is a vacant single‐family residence located at a 2367, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.
Storage Building 653: This building is a 7’x12’ wooden storage building, located behind Building 603, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.
Dwelling Building 604: This structure is a vacant single‐family residence located at a 2381, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.
Storage Building 654: This building is a 7’x12’ wooden storage building, located behind Building 604, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.
Dwelling Building 605: This structure is a vacant single‐family residence located at a 2397, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.
Witherbee Site Page 3 of 4
Storage Building 655: This building is a 7’x12’ wooden storage building, located behind Building 605, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.
Well House: The well house is situated centrally between Dwelling Building 603 and Dwelling Building 604. It is a concrete structure with a shingled roof, which is surrounded by a chain link fence. All equipment associated with the well house is metal.
Inspection Strategy/Sampling Protocol
The inspection consisted of grouping suspect asbestos containing materials into homogeneous areas based on the color and texture of the material, and then performing representative sampling of the materials included in those homogeneous areas. SC‐DHEC has requirements for the minimum number of samples that can be collected from each homogeneous area (three samples of each miscellaneous material, three samples of each type of thermal system insulation, and the sample requirements for surfacing are based on square footage). Following completion of the on‐site inspection/sampling, samples were submitted to an accredited laboratory for analysis.
As of June 27, 2008, SC‐DHEC requires that any non‐friable organically bound (NOB) material that is suspect to contain asbestos, such as floor tile, mastics, roofing material, and caulking must be analyzed by transmission electron microscopy (TEM) if polarized light microscopy (PLM) analyses of that material indicate that no asbestos was detected.
Results
EPA recognizes a material as Asbestos Containing Material (ACM) if an asbestos content of greater than one percent asbestos is detected in a representative sample analyzed by polarized light microscopy. It should be noted that items containing <1% asbestos are covered to some extent by the OSHA’s Asbestos Standard for the Construction Industry
(29 CFR 1926.1101).
No asbestos was detected in association with the storage buildings (Buildings 652‐655) and well house.
All suspect materials identified in the dwellings were found to have been sufficiently sampled, and the previously assessed condition of asbestos‐containing materials identified in the Trident Environmental report are still accurate. The only discrepancy identified was that in the report for Dwelling Building 603 (2367 Witherbee Rd.), the previous report identifies the ACM flooring as being located in the kitchen; however, it is also located in the adjoining Laundry Room. The quantity provided in the Trident report included both (the total quantity provided is accurate).
Witherbee Site Page 4 of 4
Relevant Regulatory Requirements/Recommendations
Friability‐Friable materials are defined as materials that can be reduced to powder by hand pressure. It should be noted that non‐friable materials may become friable depending on the method of removal. All non‐friable materials must be removed by properly accredited asbestos personnel. If the non‐friable materials are removed in a friable manner, then all regulations in regards to friable abatement will apply, and the abatement must be performed by a SC‐DHEC Licensed Asbestos Contractor, and in accordance with all state and federal regulations.
Project Design‐ Project Design written by a SC‐DHEC Licensed Project Designer will be required on this project.
Air Monitoring‐ Air monitoring by a SC‐DHEC Licensed Air Monitor will be required on this project.
CRE can further assist with Project Design, Air Monitoring, and/or help in selecting an asbestos abatement contractor.
Closing Statements and Limitations
Every effort was made to identify all materials in accessible areas. There is the possibility that suspect materials were not identified in inaccessible areas. If any suspect material is discovered that is not included within this report, it should be sampled before it is physically disturbed.
This document has been prepared by Crossroads Environmental, LLC at the request of and for the exclusive use of the Francis Marion & Sumter National Forest Service. This report represents the findings from the date that it was inspected, and is limited in scope to that indicated above.
Crossroads Environmental, LLC appreciates the opportunity to provide the Francis Marion & Sumter National Forest Service with our consultative services. Should you have any questions or need additional information, please do not hesitate to contact us.
Sincerely, Kay Horton Licensed Asbestos Inspector
ATTACHMENT I
ASBESTOS SUMMARY TABLE
CRE JOB #: 18039‐IN
Location:
Client: DATE: 4/10/2020
HA#
Type of
Material
TSI, Surf, Misc.
Material Type Sample Number
Asbestos
Content
(PLM)
Asbestos
Content
(TEM)
Location of Sample Approx.
Quantity
Physical
Condition Location/ Comments
131‐Shingle Layer 1
131‐Shingle Layer 2
132‐Felt
NAD
NAD
NAD
Front
132‐Shingle Layer 1
132‐Shingle Layer 2
132‐Felt
NAD
NAD
NAD
Back
133‐Shingle Layer 1
133‐Shingle Layer 2
133‐Felt
NAD
NAD
NAD
Side
134‐Shingle Layer 1
134‐Shingle Layer 2
134‐Felt
NAD
NAD
NAD
Front
135‐Shingle Layer 1
135‐Shingle Layer 2
135‐Felt
NAD
NAD
NAD
Back
136‐Shingle Layer 1
136‐Shingle Layer 2
136‐Felt
NAD
NAD
NAD
Side
137‐Shingle Layer 1
137‐Shingle Layer 2
137‐Felt
NAD
NAD
NAD
Front
138‐Shingle Layer 1
138‐Shingle Layer 2
138‐Felt
NAD
NAD
NAD
Back
139‐Shingle Layer 1
139‐Shingle Layer 2
139‐Felt
NAD
NAD
NAD
Side
140‐Shingle Layer 1
140‐Shingle Layer 2
140‐Felt
NAD
NAD
NAD
Front
141‐Shingle Layer 1
141‐Shingle Layer 2
141‐Felt
NAD
NAD
NAD
Back
142‐Shingle Layer 1
142‐Shingle Layer 2
142‐Felt
NAD
NAD
NAD
Side
CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT
Witherbee Site, Cordesville, South Carolina
Francis Marion & Sumter National Forest Service
Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built‐up Roofing, Surf=Surfacing
NAD=No Asbestos Detected, SP=Stop Positive
01 Misc.
Roofing Shingles &
Felt N/A
Good;
Friable Located on the roof of Building 655.
02 Misc.
Roofing Shingles &
Felt N/A
Good;
Friable Located on the roof of Building 654.
03 Misc.
Roofing Shingles &
Felt N/A
Good;
Friable
Located on the roof of the Well
House.
04 Misc.
Roofing Shingles &
Felt N/A
Good;
Friable Located on the roof of Building 653.
Asbestos Inspector's Accreditation #: ASB-23394 Asbestos Inspector Printed Name: Kay H. Horton Page 1 of 2
CRE JOB #: 18039‐IN
Location:
Client: DATE: 4/10/2020
HA#
Type of
Material
TSI, Surf, Misc.
Material Type Sample Number
Asbestos
Content
(PLM)
Asbestos
Content
(TEM)
Location of Sample Approx.
Quantity
Physical
Condition Location/ Comments
CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT
Witherbee Site, Cordesville, South Carolina
Francis Marion & Sumter National Forest Service
Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built‐up Roofing, Surf=Surfacing
NAD=No Asbestos Detected, SP=Stop Positive
143‐Shingle Layer 1
143‐Tar
143‐Shingle Layer 2
143‐Tar
143‐Felt
NAD
NAD
NAD
NAD
NAD
Front
144‐Shingle Layer 1
144‐Tar
144‐Shingle Layer 2
144‐Tar
144‐Felt
NAD
NAD
NAD
NAD
NAD
Back
145‐Shingle Layer 1
145‐Tar
145‐Shingle Layer 2
145‐Tar
145‐Felt
NAD
NAD
NAD
NAD
NAD
Side
05 Misc.
Roofing Shingles &
Felt N/A
Good;
Friable Located on the roof of Building 652.
Asbestos Inspector's Accreditation #: ASB-23394 Asbestos Inspector Printed Name: Kay H. Horton Page 2 of 2
ATTACHMENT II
LABORATORY REPORT(S)
April 15, 2020
Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
CLIENT PROJECT: 18039-IN (Witherbee)
CEI LAB CODE: A204621
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 14, 2020. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Crossroads Environmental
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
18039-IN (Witherbee)
A204621
04/15/20
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 18039-IN (Witherbee) LAB CODE: A204621
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Layer 1 A75507A Black,Brown Roofing Shingle None Detected131
Layer 2 A75507A Black,Brown Roofing Shingle None Detected
A75507B Black Felt None Detected
Layer 1 A75508A Black,Brown Roofing Shingle None Detected132
Layer 2 A75508A Black,Brown Roofing Shingle None Detected
A75508B Black Felt None Detected
Layer 1 A75509A Sample Submitted for TEM Analysis
Layer 2 A75509A Sample Submitted for TEM Analysis
A75509B Sample Submitted for TEM Analysis
Layer 1 A75510A Black,Brown Roofing Shingle None Detected134
Layer 2 A75510A Black,Brown Roofing Shingle None Detected
A75510B Black Felt None Detected
Layer 1 A75511A Black,Brown Roofing Shingle None Detected135
Layer 2 A75511A Black,Brown Roofing Shingle None Detected
A75511B Black Felt None Detected
Layer 1 A75512A Sample Submitted for TEM Analysis
Layer 2 A75512A Sample Submitted for TEM Analysis
A75512B Sample Submitted for TEM Analysis
Layer 1 A75513 Black,Gray Roofing Shingle None Detected137
Layer 2 A75513 Black Felt None Detected
Layer 1 A75514 Black,Gray Roofing Shingle None Detected138
Layer 2 A75514 Black Felt None Detected
Layer 1 A75515 Sample Submitted for TEM Analysis
Layer 2 A75515 Sample Submitted for TEM Analysis
Layer 1 A75516 Black,Gray Roofing Shingle None Detected140
Asbestos Report Summary
PROJECT: 18039-IN (Witherbee) LAB CODE: A204621
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Layer 2 A75516 Black Felt None Detected
Layer 1 A75517 Black,Gray Roofing Shingle None Detected141
Layer 2 A75517 Black Felt None Detected
Layer 1 A75518 Sample Submitted for TEM Analysis
Layer 2 A75518 Sample Submitted for TEM Analysis
Layer 1 A75519A Black,Brown Roofing Shingle None Detected143
Layer 2 A75519A Black Tar None Detected
Layer 3 A75519A Black,Brown Roofing Shingle None Detected
Layer 4 A75519A Black Tar None Detected
A75519B Black Felt None Detected
Layer 1 A75520A Black,Brown Roofing Shingle None Detected144
Layer 2 A75520A Black Tar None Detected
Layer 3 A75520A Black,Brown Roofing Shingle None Detected
Layer 4 A75520A Black Tar None Detected
A75520B Black Felt None Detected
Layer 1 A75521A Sample Submitted for TEM Analysis
Layer 2 A75521A Sample Submitted for TEM Analysis
Layer 3 A75521A Sample Submitted for TEM Analysis
Layer 4 A75521A Sample Submitted for TEM Analysis
A75521B Sample Submitted for TEM Analysis
ASBESTOS BULK ANALYSIS
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Black,Brown
A75507A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black,Brown Roofing Shingle
A75507A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 2
Black FeltA75507B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
Black,Brown
A75508A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black,Brown Roofing Shingle
A75508A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 2
Black FeltA75508B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
A75509A Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisA75509A
Layer 2
Sample Submitted for TEM Analysis
A75509B
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Black,Brown
A75510A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black,Brown Roofing Shingle
A75510A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 2
Black FeltA75510B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
Black,Brown
A75511A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black,Brown Roofing Shingle
A75511A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 2
Black FeltA75511B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
A75512A Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisA75512A
Layer 2
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Sample Submitted for TEM Analysis
A75512B
Black,Gray
A75513
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black Felt
A75513 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None DetectedLayer 2
Black,Gray
A75514
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black Felt
A75514 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None DetectedLayer 2
A75515 Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisA75515
Layer 2
Black,Gray
A75516
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Black Felt
A75516 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None DetectedLayer 2
Black,Gray
A75517
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black Felt
A75517 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None DetectedLayer 2
A75518 Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisA75518
Layer 2
Black,Brown
A75519A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black Tar
A75519A Homogeneous
Non-fibrous Tightly Bound
98% 2%
Tar Silicates
None DetectedLayer 2
Black,Brown Roofing Shingle
A75519A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 3
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Black Tar
A75519A Homogeneous
Non-fibrous Tightly Bound
100% Tar None DetectedLayer 4
Black FeltA75519B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
Black,Brown
A75520A
40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None Detected Layer 1
Roofing Shingle
Black Tar
A75520A Homogeneous
Non-fibrous Tightly Bound
98% 2%
Tar Silicates
None DetectedLayer 2
Black,Brown Roofing Shingle
A75520A 40%Heterogeneous
Fibrous Tightly Bound
35% 15% 10%
Fiberglass Tar Gravel Binder
None DetectedLayer 3
Black Tar
A75520A Homogeneous
Non-fibrous Tightly Bound
100% Tar None DetectedLayer 4
Black FeltA75520B 85%Homogeneous
Fibrous Tightly Bound
15%Cellulose Tar None Detected
A75521A Layer 1
Sample Submitted for TEM Analysis
Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Fibrous
Sample Submitted for TEM AnalysisA75521A
Layer 2
Sample Submitted for TEM AnalysisA75521A
Layer 3
Sample Submitted for TEM AnalysisA75521A
Layer 4
Sample Submitted for TEM Analysis
A75521B
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH
McLane Brown
April 17, 2020
Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
CLIENT PROJECT: 18039-IN (Witherbee)
LAB CODE: T200812
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 15, 2020. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Crossroads Environmental
AMENDED
due to
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
18039-IN (Witherbee)
T200812
04/16/20
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T200812 Date Received: 04-15-20 Date Analyzed: 04-16-20 Date Reported: 04-16-20
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
AMENDED
due to
T05044 133 Roofing Shingle 1 0.296 36.1 9.8 54.1 None
Detected
T05045 133 Roofing Shingle 2 0.248 38.7 18.5 42.8 None
Detected
T05046 133 Felt 0.166 95.8 1.8 2.4 None
Detected
T05047 136 Roofing Shingle 1 0.19 26.3 37.9 35.8 None
Detected
T05048 136 Roofing Shingle 2 0.269 27.1 38.7 34.2 None
Detected
T05049 136 Felt 0.466 95.1 1.1 3.8 None
Detected
T05050 139 Roofing Shingle 1 0.224 33.9 47.3 18.8 None
Detected
T05051 139 Felt 0.535 94.6 1.7 3.7 None
Detected
T05189 139 Roofing Shingle 2 0.695 28.8 36.3 34.9 None
Detected
T05052 142 Roofing Shingle 1 0.156 30.1 47.4 22.5 None
Detected
T05053 142 Felt 0.543 96.7 3.1 .2 None
Detected
T05190 142 Roofing Shingle 2 0.494 28.9 42.3 28.8 None
Detected
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T200812 Date Received: 04-15-20 Date Analyzed: 04-16-20 Date Reported: 04-16-20
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: 18039-IN (Witherbee)
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
AMENDED
due to
T05054 145 Roofing Shingle 1 0.374 19.8 27.3 52.9 None
Detected
T05055 145 Tar 0.288 27.8 20.8 51.4 None
Detected
T05056 145 Roofing Shingle 2 0.444 21.2 33.6 45.2 None
Detected
T05057 145 Tar 0.064 34.4 43.8 21.8 None
Detected
T05058 145 Felt 0.676 96 1.9 2.1 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Emily Morris
AMENDED due to Client Wishes to Change Specifications for Analysis - Samples split to form additional samples
ATTACHMENT III
SAMPLE LOCATION SKETCH
ATTACHMENT IV
ACCREDITATION(S)
| Title Page and TOC 18039 |
| SC inspection letter 18039 |
| ATTACHMENT I Asbestos |
| SC Asbestos Table 18039 |
| ATTACHMENT II Reports |
| A204621 |
| A204621_4_15_2020_7_40_23_Asbestos_Report |
| A204621 |
| T200812V2 |
| T200812AMENDED due to Client Wishes to Change Specifications for Analysis - Samples split to form additional samples_4_17_2020_8_53_12_TEM_Bulk_Chatfield_PLUS_Analysis_Worksheets_Report |
| T200812 |
| ATTACHMENT III Sketch-Photo SC |
| Witherbee houses site diagram (002) |
| ATTACHMENT IV SC License |
| Air Sampler_ConsultPD_ConsultMP_Exp. 8-18-20 |
File details come from the government source that posted it. Updated .