1258 Boiling Springs Road • Spartanburg, SC 29303 • Phone 864‐541‐8736 / Fax 864‐541‐8776 www.crossroadsenv.net

ASBESTOS INSPECTION REPORT

FOR

CLIENT

Francis Marion & Sumter National Forest

4931 Broad River Road Abbeville, SC 29620

SITE LOCATION

Witherbee Site

2355, 2367, 2381 & 2397 Witherbee Road Cordesville, South Carolina

INSPECTION DATE: April 10, 2020 REPORT DATE: April 17, 2020

INSPECTOR

Kay H. Horton – SC‐DHEC License #ASB‐23394

(864) 541‐8736

For

Crossroads Environmental, LLC 1258 Boiling Springs Road

Spartanburg, South Carolina 29303

(864) 541‐8736

CRE Project # 18039‐IN

TABLE OF CONTENTS

INSPECTION REPORT/LETTER

BACKGROUND INFORMATION

BUILDING/AREA DESCRIPTION

INSPECTION STRATEGY/SAMPLING PROTOCOL

RESULTS

RELEVANT REGULATORY REQUIREMENTS/RECOMMENDATIONS

CLOSING STATEMENTS AND LIMITATIONS

ATTACHMENTS

ATTACHMENT I: ASBESTOS SUMMARY TABLE

ATTACHMENT II: LABORATORY REPORT

ATTACHMENT III: BUILDING/AREA SKETCH

ATTACHMENT IV: INSPECTOR’S LICENSE/ACCREDITATION

April 17, 2020

Mr. Mike Alcorn Forest Service Francis Marion & Sumter National Forest Service 4931 Broad River Road Columbia, SC 29212

Re: Asbestos Inspection Report 2355, 2367, 2381 & 2397 Witherbee Road

Cordesville, South Carolina CRE Project Number: 18039‐IN

Dear Mr. Alcorn:

Crossroads Environmental, LLC (CRE) completed an asbestos inspection of the Witherbee Site, located on Witherbee Road in Cordesville, SC on April 10, 2020. The inspection was performed by a SC‐DHEC Licensed Asbestos Inspector, and in accordance with South Carolina Department of Health and Environmental Control (SC‐DHEC) and Environmental Protection Agency (EPA) Requirements. A detailed summary table of the sampling is included in Attachment I; however, this report should be read in its entirety.

Building(s) Description/Scope of Work

The Witherbee Site, part of Francis Marion & Sumter National Forest, consists of four (4) houses, an associated storage building for each house, and one central well house. All structures are scheduled for demolition. Comprehensive asbestos inspections of the houses were performed by Trident Environmental in 2014, but the storage buildings and well house were excluded.

In accordance with SC‐DHEC’s Regulation 61‐86.1, Standards of Performance for Asbestos Projects (effective May 27, 2011), “to be acceptable, a building inspection shall have been performed no earlier than three years prior to the renovation of demolition, or if more than three years have elapsed since the most recent inspection, the previous inspection shall be confirmed and verified by a person licensed as a building inspector”.

CRE performed the required confirmation/verification of the inspection report provided by Trident Environmental. Additionally, comprehensive asbestos inspections of the storage buildings and well house were performed.

Asbestos Inspection Report April 17, 2020 Witherbee Site Page 2 of 4 Project Number: 18039‐IN

The structures included are as follows:

Dwelling Building 602: This structure is a vacant single‐family residence located at a 2355 Witherbee Road, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.

Storage Building 652: This building is a 7’x12’ wooden storage building, located behind Building 602, which has wood siding, concrete floor, and a shingled roof. The building has metal framed windows. No suspect window glaze or caulk were identified in association with the windows.

Dwelling Building 603: This structure is a vacant single‐family residence located at a 2367, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.

Storage Building 653: This building is a 7’x12’ wooden storage building, located behind Building 603, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.

Dwelling Building 604: This structure is a vacant single‐family residence located at a 2381, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.

Storage Building 654: This building is a 7’x12’ wooden storage building, located behind Building 604, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.

Dwelling Building 605: This structure is a vacant single‐family residence located at a 2397, which is approximately 1,800 sq. ft. in size. The house has wood siding, a sloped shingled roof, and is built over a crawlspace. Interior finishes include drywall walls and ceilings; and flooring consisting of a combination of hardwood floors, carpet, vinyl flooring, and ceramic. No suspect asbestos‐containing materials were identified in the attic or crawlspace.

Witherbee Site Page 3 of 4

Storage Building 655: This building is a 7’x12’ wooden storage building, located behind Building 605, which has wood siding, concrete floor, and a shingled roof. No suspect window glaze or caulk were identified in association with the windows.

Well House: The well house is situated centrally between Dwelling Building 603 and Dwelling Building 604. It is a concrete structure with a shingled roof, which is surrounded by a chain link fence. All equipment associated with the well house is metal.

Inspection Strategy/Sampling Protocol

The inspection consisted of grouping suspect asbestos containing materials into homogeneous areas based on the color and texture of the material, and then performing representative sampling of the materials included in those homogeneous areas. SC‐DHEC has requirements for the minimum number of samples that can be collected from each homogeneous area (three samples of each miscellaneous material, three samples of each type of thermal system insulation, and the sample requirements for surfacing are based on square footage). Following completion of the on‐site inspection/sampling, samples were submitted to an accredited laboratory for analysis.

As of June 27, 2008, SC‐DHEC requires that any non‐friable organically bound (NOB) material that is suspect to contain asbestos, such as floor tile, mastics, roofing material, and caulking must be analyzed by transmission electron microscopy (TEM) if polarized light microscopy (PLM) analyses of that material indicate that no asbestos was detected.

Results

EPA recognizes a material as Asbestos Containing Material (ACM) if an asbestos content of greater than one percent asbestos is detected in a representative sample analyzed by polarized light microscopy. It should be noted that items containing <1% asbestos are covered to some extent by the OSHA’s Asbestos Standard for the Construction Industry

(29 CFR 1926.1101).

No asbestos was detected in association with the storage buildings (Buildings 652‐655) and well house.

All suspect materials identified in the dwellings were found to have been sufficiently sampled, and the previously assessed condition of asbestos‐containing materials identified in the Trident Environmental report are still accurate. The only discrepancy identified was that in the report for Dwelling Building 603 (2367 Witherbee Rd.), the previous report identifies the ACM flooring as being located in the kitchen; however, it is also located in the adjoining Laundry Room. The quantity provided in the Trident report included both (the total quantity provided is accurate).

Witherbee Site Page 4 of 4

Relevant Regulatory Requirements/Recommendations

Friability‐Friable materials are defined as materials that can be reduced to powder by hand pressure. It should be noted that non‐friable materials may become friable depending on the method of removal. All non‐friable materials must be removed by properly accredited asbestos personnel. If the non‐friable materials are removed in a friable manner, then all regulations in regards to friable abatement will apply, and the abatement must be performed by a SC‐DHEC Licensed Asbestos Contractor, and in accordance with all state and federal regulations.

Project Design‐ Project Design written by a SC‐DHEC Licensed Project Designer will be required on this project.

Air Monitoring‐ Air monitoring by a SC‐DHEC Licensed Air Monitor will be required on this project.

CRE can further assist with Project Design, Air Monitoring, and/or help in selecting an asbestos abatement contractor.

Closing Statements and Limitations

Every effort was made to identify all materials in accessible areas. There is the possibility that suspect materials were not identified in inaccessible areas. If any suspect material is discovered that is not included within this report, it should be sampled before it is physically disturbed.

This document has been prepared by Crossroads Environmental, LLC at the request of and for the exclusive use of the Francis Marion & Sumter National Forest Service. This report represents the findings from the date that it was inspected, and is limited in scope to that indicated above.

Crossroads Environmental, LLC appreciates the opportunity to provide the Francis Marion & Sumter National Forest Service with our consultative services. Should you have any questions or need additional information, please do not hesitate to contact us.

Sincerely, Kay Horton Licensed Asbestos Inspector

ATTACHMENT I

ASBESTOS SUMMARY TABLE

CRE JOB #: 18039‐IN

Location:

Client: DATE: 4/10/2020

HA#

Type of

Material

TSI, Surf, Misc.

Material Type Sample Number

Asbestos

Content

(PLM)

Asbestos

Content

(TEM)

Location of Sample Approx.

Quantity

Physical

Condition Location/ Comments

131‐Shingle Layer 1

131‐Shingle Layer 2

132‐Felt

NAD

NAD

NAD

Front

132‐Shingle Layer 1

132‐Shingle Layer 2

132‐Felt

NAD

NAD

NAD

Back

133‐Shingle Layer 1

133‐Shingle Layer 2

133‐Felt

NAD

NAD

NAD

Side

134‐Shingle Layer 1

134‐Shingle Layer 2

134‐Felt

NAD

NAD

NAD

Front

135‐Shingle Layer 1

135‐Shingle Layer 2

135‐Felt

NAD

NAD

NAD

Back

136‐Shingle Layer 1

136‐Shingle Layer 2

136‐Felt

NAD

NAD

NAD

Side

137‐Shingle Layer 1

137‐Shingle Layer 2

137‐Felt

NAD

NAD

NAD

Front

138‐Shingle Layer 1

138‐Shingle Layer 2

138‐Felt

NAD

NAD

NAD

Back

139‐Shingle Layer 1

139‐Shingle Layer 2

139‐Felt

NAD

NAD

NAD

Side

140‐Shingle Layer 1

140‐Shingle Layer 2

140‐Felt

NAD

NAD

NAD

Front

141‐Shingle Layer 1

141‐Shingle Layer 2

141‐Felt

NAD

NAD

NAD

Back

142‐Shingle Layer 1

142‐Shingle Layer 2

142‐Felt

NAD

NAD

NAD

Side

CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT

Witherbee Site, Cordesville, South Carolina

Francis Marion & Sumter National Forest Service

Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built‐up Roofing, Surf=Surfacing

NAD=No Asbestos Detected, SP=Stop Positive

01 Misc.

Roofing Shingles &

Felt N/A

Good;

Friable Located on the roof of Building 655.

02 Misc.

Roofing Shingles &

Felt N/A

Good;

Friable Located on the roof of Building 654.

03 Misc.

Roofing Shingles &

Felt N/A

Good;

Friable

Located on the roof of the Well

House.

04 Misc.

Roofing Shingles &

Felt N/A

Good;

Friable Located on the roof of Building 653.

Asbestos Inspector's Accreditation #: ASB-23394 Asbestos Inspector Printed Name: Kay H. Horton Page 1 of 2

CRE JOB #: 18039‐IN

Location:

Client: DATE: 4/10/2020

HA#

Type of

Material

TSI, Surf, Misc.

Material Type Sample Number

Asbestos

Content

(PLM)

Asbestos

Content

(TEM)

Location of Sample Approx.

Quantity

Physical

Condition Location/ Comments

CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT

Witherbee Site, Cordesville, South Carolina

Francis Marion & Sumter National Forest Service

Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built‐up Roofing, Surf=Surfacing

NAD=No Asbestos Detected, SP=Stop Positive

143‐Shingle Layer 1

143‐Tar

143‐Shingle Layer 2

143‐Tar

143‐Felt

NAD

NAD

NAD

NAD

NAD

Front

144‐Shingle Layer 1

144‐Tar

144‐Shingle Layer 2

144‐Tar

144‐Felt

NAD

NAD

NAD

NAD

NAD

Back

145‐Shingle Layer 1

145‐Tar

145‐Shingle Layer 2

145‐Tar

145‐Felt

NAD

NAD

NAD

NAD

NAD

Side

05 Misc.

Roofing Shingles &

Felt N/A

Good;

Friable Located on the roof of Building 652.

Asbestos Inspector's Accreditation #: ASB-23394 Asbestos Inspector Printed Name: Kay H. Horton Page 2 of 2

ATTACHMENT II

LABORATORY REPORT(S)

April 15, 2020

Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

CLIENT PROJECT: 18039-IN (Witherbee)

CEI LAB CODE: A204621

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 14, 2020. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Polarized Light Microscopy

Prepared for

Crossroads Environmental

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

18039-IN (Witherbee)

A204621

04/15/20

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: 18039-IN (Witherbee) LAB CODE: A204621

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 1 A75507A Black,Brown Roofing Shingle None Detected131

Layer 2 A75507A Black,Brown Roofing Shingle None Detected

A75507B Black Felt None Detected

Layer 1 A75508A Black,Brown Roofing Shingle None Detected132

Layer 2 A75508A Black,Brown Roofing Shingle None Detected

A75508B Black Felt None Detected

Layer 1 A75509A Sample Submitted for TEM Analysis

Layer 2 A75509A Sample Submitted for TEM Analysis

A75509B Sample Submitted for TEM Analysis

Layer 1 A75510A Black,Brown Roofing Shingle None Detected134

Layer 2 A75510A Black,Brown Roofing Shingle None Detected

A75510B Black Felt None Detected

Layer 1 A75511A Black,Brown Roofing Shingle None Detected135

Layer 2 A75511A Black,Brown Roofing Shingle None Detected

A75511B Black Felt None Detected

Layer 1 A75512A Sample Submitted for TEM Analysis

Layer 2 A75512A Sample Submitted for TEM Analysis

A75512B Sample Submitted for TEM Analysis

Layer 1 A75513 Black,Gray Roofing Shingle None Detected137

Layer 2 A75513 Black Felt None Detected

Layer 1 A75514 Black,Gray Roofing Shingle None Detected138

Layer 2 A75514 Black Felt None Detected

Layer 1 A75515 Sample Submitted for TEM Analysis

Layer 2 A75515 Sample Submitted for TEM Analysis

Layer 1 A75516 Black,Gray Roofing Shingle None Detected140

Asbestos Report Summary

PROJECT: 18039-IN (Witherbee) LAB CODE: A204621

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 2 A75516 Black Felt None Detected

Layer 1 A75517 Black,Gray Roofing Shingle None Detected141

Layer 2 A75517 Black Felt None Detected

Layer 1 A75518 Sample Submitted for TEM Analysis

Layer 2 A75518 Sample Submitted for TEM Analysis

Layer 1 A75519A Black,Brown Roofing Shingle None Detected143

Layer 2 A75519A Black Tar None Detected

Layer 3 A75519A Black,Brown Roofing Shingle None Detected

Layer 4 A75519A Black Tar None Detected

A75519B Black Felt None Detected

Layer 1 A75520A Black,Brown Roofing Shingle None Detected144

Layer 2 A75520A Black Tar None Detected

Layer 3 A75520A Black,Brown Roofing Shingle None Detected

Layer 4 A75520A Black Tar None Detected

A75520B Black Felt None Detected

Layer 1 A75521A Sample Submitted for TEM Analysis

Layer 2 A75521A Sample Submitted for TEM Analysis

Layer 3 A75521A Sample Submitted for TEM Analysis

Layer 4 A75521A Sample Submitted for TEM Analysis

A75521B Sample Submitted for TEM Analysis

ASBESTOS BULK ANALYSIS

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Black,Brown

A75507A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black,Brown Roofing Shingle

A75507A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 2

Black FeltA75507B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

Black,Brown

A75508A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black,Brown Roofing Shingle

A75508A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 2

Black FeltA75508B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

A75509A Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisA75509A

Layer 2

Sample Submitted for TEM Analysis

A75509B

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Black,Brown

A75510A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black,Brown Roofing Shingle

A75510A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 2

Black FeltA75510B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

Black,Brown

A75511A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black,Brown Roofing Shingle

A75511A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 2

Black FeltA75511B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

A75512A Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisA75512A

Layer 2

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Sample Submitted for TEM Analysis

A75512B

Black,Gray

A75513

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black Felt

A75513 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None DetectedLayer 2

Black,Gray

A75514

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black Felt

A75514 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None DetectedLayer 2

A75515 Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisA75515

Layer 2

Black,Gray

A75516

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Black Felt

A75516 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None DetectedLayer 2

Black,Gray

A75517

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black Felt

A75517 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None DetectedLayer 2

A75518 Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisA75518

Layer 2

Black,Brown

A75519A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black Tar

A75519A Homogeneous

Non-fibrous Tightly Bound

98% 2%

Tar Silicates

None DetectedLayer 2

Black,Brown Roofing Shingle

A75519A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 3

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Black Tar

A75519A Homogeneous

Non-fibrous Tightly Bound

100% Tar None DetectedLayer 4

Black FeltA75519B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

Black,Brown

A75520A

40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None Detected Layer 1

Roofing Shingle

Black Tar

A75520A Homogeneous

Non-fibrous Tightly Bound

98% 2%

Tar Silicates

None DetectedLayer 2

Black,Brown Roofing Shingle

A75520A 40%Heterogeneous

Fibrous Tightly Bound

35% 15% 10%

Fiberglass Tar Gravel Binder

None DetectedLayer 3

Black Tar

A75520A Homogeneous

Non-fibrous Tightly Bound

100% Tar None DetectedLayer 4

Black FeltA75520B 85%Homogeneous

Fibrous Tightly Bound

15%Cellulose Tar None Detected

A75521A Layer 1

Sample Submitted for TEM Analysis

Lab Code: A204621 Date Received: 04-14-20 Date Analyzed: 04-14-20 Date Reported: 04-15-20

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Fibrous

Sample Submitted for TEM AnalysisA75521A

Layer 2

Sample Submitted for TEM AnalysisA75521A

Layer 3

Sample Submitted for TEM AnalysisA75521A

Layer 4

Sample Submitted for TEM Analysis

A75521B

LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORTING LIMIT: <1% by visual estimation

REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points

REGULATORY LIMIT: >1% by weight

Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Information provided by customer includes customer sample ID and sample description.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH

McLane Brown

April 17, 2020

Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

CLIENT PROJECT: 18039-IN (Witherbee)

LAB CODE: T200812

Dear Customer:

Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 15, 2020. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.

Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Transmission Electron Microscopy

Prepared for

Crossroads Environmental

AMENDED

due to

CLIENT PROJECT:

LAB CODE:

TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1

REPORT DATE:

18039-IN (Witherbee)

T200812

04/16/20

By: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T200812 Date Received: 04-15-20 Date Analyzed: 04-16-20 Date Reported: 04-16-20

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Sample Weight

(g)

Organic Material

Acid Soluble Material

Acid Insoluble Material

Asbestos

AMENDED

due to

T05044 133 Roofing Shingle 1 0.296 36.1 9.8 54.1 None

Detected

T05045 133 Roofing Shingle 2 0.248 38.7 18.5 42.8 None

Detected

T05046 133 Felt 0.166 95.8 1.8 2.4 None

Detected

T05047 136 Roofing Shingle 1 0.19 26.3 37.9 35.8 None

Detected

T05048 136 Roofing Shingle 2 0.269 27.1 38.7 34.2 None

Detected

T05049 136 Felt 0.466 95.1 1.1 3.8 None

Detected

T05050 139 Roofing Shingle 1 0.224 33.9 47.3 18.8 None

Detected

T05051 139 Felt 0.535 94.6 1.7 3.7 None

Detected

T05189 139 Roofing Shingle 2 0.695 28.8 36.3 34.9 None

Detected

T05052 142 Roofing Shingle 1 0.156 30.1 47.4 22.5 None

Detected

T05053 142 Felt 0.543 96.7 3.1 .2 None

Detected

T05190 142 Roofing Shingle 2 0.494 28.9 42.3 28.8 None

Detected

By: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T200812 Date Received: 04-15-20 Date Analyzed: 04-16-20 Date Reported: 04-16-20

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1

Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303

Project: 18039-IN (Witherbee)

Sample Weight

(g)

Organic Material

Acid Soluble Material

Acid Insoluble Material

Asbestos

AMENDED

due to

T05054 145 Roofing Shingle 1 0.374 19.8 27.3 52.9 None

Detected

T05055 145 Tar 0.288 27.8 20.8 51.4 None

Detected

T05056 145 Roofing Shingle 2 0.444 21.2 33.6 45.2 None

Detected

T05057 145 Tar 0.064 34.4 43.8 21.8 None

Detected

T05058 145 Felt 0.676 96 1.9 2.1 None

Detected

LEGEND: None

METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1

LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)

REGULATORY LIMIT: >1% by weight

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request. Samples were received in acceptable condition unless otherwise noted.

Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Emily Morris

AMENDED due to Client Wishes to Change Specifications for Analysis - Samples split to form additional samples

ATTACHMENT III

SAMPLE LOCATION SKETCH

ATTACHMENT IV

ACCREDITATION(S)

Title Page and TOC 18039
SC inspection letter 18039
ATTACHMENT I Asbestos
SC Asbestos Table 18039
ATTACHMENT II Reports
A204621
A204621_4_15_2020_7_40_23_Asbestos_Report
A204621
T200812V2
T200812AMENDED due to Client Wishes to Change Specifications for Analysis - Samples split to form additional samples_4_17_2020_8_53_12_TEM_Bulk_Chatfield_PLUS_Analysis_Worksheets_Report
T200812
ATTACHMENT III Sketch-Photo SC
Witherbee houses site diagram (002)
ATTACHMENT IV SC License
Air Sampler_ConsultPD_ConsultMP_Exp. 8-18-20