About this file

This document is a detailed specification and photographic record for residential repairs and renovations at a federal property.

Scope of Work and Materials: The project encompasses repairs, replacements, and removals across multiple building systems and finishes. Windows require replacement of four known ¼-inch plate glass lites (approximately 10"X14") that are cracked, with lites and reglaze work required. One interior door consists of hollow core birch veneer construction (30" X 6'8") with reuse of existing hardware. HVAC work includes installation of a new 3-ton cooling system with paired cooling coil and natural gas furnace, Energy Star compliant per SOW specifications, with no brand preference. Drainage/sewer work requires replacement of approximately 10 linear feet of cast iron pipe from a Fernco connection in the crawlspace under the exterior wall to an existing cleanout, with connections to existing PVC on both ends. Interior finishes are limited to kitchen and bathroom areas only, totaling approximately 1,000 square feet, including all cabinet faces, walls, ceilings, and trim with flat ceilings and all other surfaces in satin finish. The contractor assumes responsibility for color matching existing finishes. No brand or material standards are specified; submittals demonstrating product appropriateness for intended use are required for all products scheduled for installation. Additional supporting documentation including photos, drawings, and inspection reports are referenced as attached but not included in this excerpt.

Property Conditions and Details: Photographic documentation reveals significant deficiencies requiring remediation: kitchen countertops show degradation with particleboard edging; bathroom caulking is deteriorated particularly around fixtures and wall joints; bathroom ceilings display extensive mold/mildew contamination; bedroom windows have multiple broken panes requiring glass replacement; a basement utility sink shows aging and deterioration; kitchen doors lack hardware (missing handle); kitchen counters show damage adjacent to appliances; and both indoor and outdoor HVAC equipment are antiquated Goodman-manufactured units from the 1980s-1990s era requiring replacement per system specifications.

View the file

Other files for this federal contract opportunity

Other files attached to Bent Creek Superintendent's Residence Repairs, newest first.
File Type Posted
Sign in Sheet.pdf PDF
Questions and Answers 12445126B0012 Pre-Bid Site Visit Summary.docx DOCX document
12445126B0012.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detailed list of all items to be repaired, replaced, or removed, with quantities if available

-Windows (type, size, quantity, condition)

4 known – ~10”X14” – ¼ Plate glass Lites Lites

1 –

1 – -

– total of ~ 1000 SF, ceilings –

See attached

Kitchen Countertop

Bathroom Caulking

Bathroom Ceiling

Bedroom 1 broken panes

House - Basement Sink

House - Bathroom

House - Kitchen 1

House - Kitchen 2

House - Kitchen 3

Indoor CentralAir Electric Components

Indoor CentralAir Label

Indoor CentralAir Unit

Indoor CentralAir Warning Label

Interior Kitchen Door MIA Handle

Kitchen Counter_lft of dishwasher

Kitchen Counter_rt of dishwasher

Outdoor CentralAir Breaker Box

Outdoor CentralAir Label

Outdoor CentralAir Label_2

Outdoor CentralAir Unit

Silicone behind Kitchen faucet

Silicone behind Kitchen faucet_2