Seeley Campground Plans.pdf

PDF 3 MB Posted

Attached to
Site Visit - GAOA Lolo Recreation Site Water System Replacements Federal contract opportunity
Solicitation number
1240LU24B0002
Issued by
Department of Agriculture Forest Service

About this file

This drawing package details proposed improvements to the water system at Seeley Lake and Riverpoint Campgrounds within the Lolo National Forest. The project includes replacing approximately 2,000 linear feet of existing 2-inch diameter water main with new polyethylene piping, installing new water services, abandoning pipes in-place, replacing an existing pump house in a new location, and connecting to existing hydrants, facilities, and services. Site plans depict the campground layout and proposed pipe routing. Relatedly, the U.S. Forest Service seeks contractor site visit support for the water system replacements through a special notice opportunity closing on April 20, 2023. Services include evaluating the project sites and existing conditions to develop independent government cost estimates.

View the file

Other files for this federal contract opportunity

Other files attached to Site Visit - GAOA Lolo Recreation Site Water System Replacements, newest first.
File Type Posted
Grizzly Campground Water System Plans.pdf PDF
Bend Guard Station Water System Improvements - Plans.pdf PDF
LeeCreekCampground_Plans.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONNECT TO EXISTING

HYDRANT SERVICE

C TO EXISTIN

RT STATION

E

0 50 100 ------ - Scale in Feet

FULLSIZE SCALE: 1"=100'

HALFSIZE SCALE: 1 "=200'

F:I1-08101-Lolo NF Seeley Lake Campground

NEW PUMP HOUSE

SEE TYPICAL TRENCH/ROAD

CROSSING DETAILffi

EXISTING PUMP HOUSE TO BE REMOVED

AND REPLACED AT NEW LOCATION.

SEE SHEET 5 FOR DETAILS.

STING WATER MAIN IN-PLACE

CL.ASS 200, POLYETHYLENE

SEE TYPICAL TRENCH DETAILffi

CONNECT TO EXISTING

HYDRANT SERVICE

CONNECT TO EXISTING

HYDRANT SERVICE

CONNECT TO EXISTING FACILITY

CONNECT O EXISTING

SERVICE

LEGEND

EXISTING CHIP SEAL ROAD

EXISTING CHIP SEAL ROAD (LOCATION APPROXIMATE)

-998- EXISTING CONTOURS

--w-- EXISTING WATER MAIN

1:8:J EXISTING PICINIC TABLE

-- ,. -- EXISTING SEWER FORCE MAIN

1%1 EXISTING SEWER COMPONENT

G, EXISTING 36" OR LARGER TREE

e EXISTING 24" OR SMALLER TREE

[ID EXISTING BUILDING

II) EXISTING POWER BOX

-w-- NEW 2" DIA. WATER MAIN

-•- NEW WATER SERVICE (CONNECT TO EXISTING)

~ NEW CONTROL POINT

EXISTING PIPE TO BE

ABANDONED IN-PLACE

Prepared By:

engineering

2501 IE.T \1EW DRIVE (408)448--M27

1-E.ENA. MONTANA 58001 REGION ONE

OVERALL SITE PLAN - SEELEY LAKE

SEELEY LAKE & RIVERPOINT CAMPGROUNDS

WATER SYSTEM IMPROVEMENTS

LOLO NATIONAL FOREST

Designed_....fl.f:.S...._Design Checked_JK. __

Drawn__}..MME...~Drawing Checked __ _ SHEET 3 of 13

Date APRIL 2008

REPLACE

REPLACE

REPLACE

REPLACE

REPLACE

CONNECTION AT

------------------- REPLACE 2" DIA. WATER MAIN

DRAFT

nkegel Highlight nkegel Highlight lrakich Draft

File details come from the government source that posted it. Updated .