1240BE26Q0065 Attachment 5 Table - Work List.xlsx
XLSX spreadsheet 27 KB Posted
- Solicitation number
- 1240BE26Q0065
About this file
This is a work list attachment detailing road maintenance quantities and specifications for the Willamette National Forest, MF 26-1 Willamette Complex North Suppression Repair project. The attachment itemizes work across multiple National Forest Service Roads (NFSR) with specific quantities and locations for surface maintenance, spot surfacing, ditch cleaning, material hauling, water bar installation, and roadside brushing activities.
The work list specifies maintenance-level 2 roads requiring spot surfacing with 3/4-inch minus material using roller compaction, with quantities totaling 121.97 miles of surface maintenance, 8,490 cubic yards of aggregate material, 8,420 cubic yards of load-haul-place operations, 12 water bar installations, 38.58 miles of ditch cleaning, 36.44 miles of ditch and drainage structure cleaning, 20 individual activities, 3.30 miles of haybale roadside brushing, and 10 miles of logging-out maintenance. All road maintenance work must be completed between June 1 and October 30, with contractor requests to work outside this window requiring verbal or written approval from the Contracting Officer's Representative following coordination with District Resource Specialists. Government-furnished culverts and guardrails must be installed by the contractor, and temporary traffic control and erosion control measures are required, particularly when working outside normal operating windows. The work spans 18 distinct road segments with varying scope requirements identified by beginning-of-project (BOP) and end-of-project (EOP) mileposts.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MF 26-1 DOW
| ATTACHMENT 5 - TABLE: WORK LIST | |||
| Willamette NF, MF 26-1 Willamette Complex SR Road Maintenance | QUANTITIES | NOTES | |
| WILLAMETTE NATIONAL FOREST |
ROAD MAINTENANCE
| SUPPLEMENTAL SPECIFICATIONS | SURFACE MAINTENANCE LEVEL 2 ROADS WITH ROLLER COMPACTION | SPOT SURFACING, GRADIATION | |||||
| 3/4 INCH MINUS | LOAD, HAUL, AND PLACE MATERIALS LESS THAN | ||||||
| 5 MILES ONE WAY HAUL | WATER BAR INSTALLATION | CLEAN DITCHES AND DRAINAGE STRUCTURES | CLEAN DITCHES | HAYBALE | ROADSIDE BRUSHING | LOGGING OUT MAINTENANCE LEVEL 2 ROADS | MOBILIZATION |
| MILEPOST | LINE ITEM NUMBER: | 0001- 811 | 0002 - 813 | 0003 - 832 | 0004 - 833 | 0005 - 834(1) | 0006 - 834(2) | 0007 - 841 | 0008 - 842 | 0009 - 851 | 881 | |
| UNIT OF MEASURE: | MI | CY | CY | EA | MI | MI | EA | MI | MI | LS | ||
| BEGIN | END | DESCRIPTION OF WORK | X - SIGNIFIES LS QUANTITY DESIGNATED AS "ALL" | |||||||||
| - | - | ALL ROADS |
- IMPLEMENT TEMPORARY TRAFFIC CONTROL,
ALL GOVERNMENT FURNISHED CULVERTS AND GUARDRAILS SUPPLIES SHALL BE FURNISHED BY THE CONTRACTOR
- IMPLEMENT EROSION CONTROL MEASURE WHEN WORKING OUTSIDE OF THE NORMAL OPERATING WINDOW.
| -ALL ROAD MAINTENANCE WORK INCLUDING BUT NOT LIMITED TO SURFACE MAINTENANCE, DITCH CLEANING, AND SPOT SURFACING SHALL BE COMPLETED BETWEEN (06/01 AND 10/30). IF THE CONTRACTOR DESIRES TO WORK OUTSIDE OF THIS WINDOW THEY MUST SUBMIT A VERBAL OR WRITTEN REQUEST TO THE COR TO CONTINUE WORK. THE COR WILL THEN MEET WITH THE DISTRICT RESOURCE SPECIALISTS TO DETERMINE IF AND WHEN THE CONTRACTOR CAN OPERATE DURING THE WET SEASON. | 20 | 20 | X | ||
| NFSR #1824000 | |||||
| 0.20 | BOP NFSR #1824000 BEGINNING OF AGGREGATE |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 9.81 | 500 | |
| 10.01 | EOP NFSR #1824000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1824140 | |
| 0.00 | BOP NFSR #1824140 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 7.11 | 400 | 700 | 7.11 |
| 7.11 | EOP NFSR #1824140 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
| NFSR #1824142 | |
| 0.00 | BOP NFSR #1824142 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING 4.51 540 240 CY of the 540 CY should be pit run borrowed from the source immediately next to the slump
4.51 EOP NFSR #1824142
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1824226 | |
| 0.00 | BOP NFSR #1824226 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 0.78 | 150 | |
| 0.78 | EOP NFSR #1824226 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1911000 | |
| 0.00 | BOP NFSR #1911000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
IV. BEGIN LOAD, HAUL, AND PLACE
| V. BEGIN INSTALL WATER BARS | 2.4 | 900 | 900 | 10 | 2.4 |
| 2.40 | EOP NFSR #1911000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
V. END INSTALL WATER BARS
| NFSR #1912000 | |
| 0.00 | BOP NFSR #1912000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES AND DRAINAGE STRUCTURES
| IV. BEGIN LOAD, HAUL, AND PLACE | 17.23 | 1000 | 1,700 | 17.23 |
| 17.23 | EOP NFSR #1911000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES AND DRAINAGE STRUCTURES
IV. END LOAD, HAUL, AND PLACE
| NFSR #1919000 | |
| 0.00 | BOP NFSR #1919000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES AND DRAINAGE STRUCTURES
| IV.BEGIN LOAD, HAUL, AND PLACE | 4.30 | 500 | 400 | 4.3 |
| 4.30 | EOP NFSR #1919000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES AND DRAINAGE STRUCTURES
IV.END LOAD, HAUL, AND PLACE
| NFSR #1920000 | |
| 0.00 | BOP NFSR #1920000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 6.30 | 100 | 650 | 6.3 |
| 6.30 | EOP NFSR #1920000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
| NFSR #1920660 | |
| 0.00 | BOP NFSR #1920660 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 3 | 100 | 100 | 3 |
| 3.00 | EOP NFSR #1920660 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
| NFSR #1925000 | |
| 0.00 | BOP NFSR #1925000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES AND DRAINAGE STRUCTURES
| IV. BEGIN LOAD, HAUL, AND PLACE | 14.95 | 250 | 1,500 | 14.95 |
| 14.95 | EOP NFSR #1925000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES AND DRAINAGE STRUCTURES
IV. END LOAD, HAUL, AND PLACE
| NFSR #1925642 | |
| 0.00 | BOP NFSR #1925642 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 5.1 | 150 | 750 | 5.1 |
| 5.10 | EOP NFSR #1925642 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
| IV. END LOAD, HAUL, AND PLACE | 1824 | ||
| NFSR #1925644 | |||
| 0.00 | BOP NFSR #1925644 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES AND DRAINAGE STRUCTURES
| IV. BEGIN LOAD, HAUL, AND PLACE | 2.1 | 100 | 420 | 2.1 |
| 2.10 | 0 | |||
| NFSR #1925646 | ||||
| 0.00 | BOP NFSR #1925646 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 2.2 | 50 | |
| 2.20 | EOP NFSR #1925646 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1926000 | |
| 3.10 | BOP NFSR #1926000 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 2.3 | 50 | |
| 5.40 | EOP NFSR #1926000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1927000 | |
| 4.95 | BOP NFSR #1927000 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 6.15 | 450 | |
| 11.10 | EOP NFSR #1927000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1927600 | |
| 0.00 | BOP NFSR #1927600 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 1.75 | 50 | |
| 1.75 | EOP NFSR #1927600 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1927606 | |
| 0.00 | BOP NFSR #1927606 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 0.63 | 100 | 110 | 0.63 |
| 0.63 | EOP NFSR #1927606 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
| NFSR #192800 | |
| 0.00 | BOP NFSR #1928000 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 7.7 | 800 | |
| 7.70 | EOP NFSR #1928000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1928704 | |
| 0.00 | BOP NFSR #1928704 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 1.8 | 360 | |
| 1.80 | EOP NFSR #1928704 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1928705 | |
| 0.00 | BOP NFSR #1928705 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 1.5 | 300 | |
| 1.50 | EOP NFSR #1928705 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1928720 | |
| 0.00 | BOP NFSR #1928720 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 0.75 | 150 | |
| 0.75 | EOP NFSR #1928720 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1928725 | |
| 0.00 | BOP NFSR #1928725 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 0.6 | 120 | |
| 0.60 | EOP NFSR #1928725 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
| NFSR #1929000 | |
| 0.00 | BOP NFSR #1929000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 7.3 | 800 | 730 | 7.3 | |
| 6.00 | I, BEGIN BRUSHING | 1.3 | |||
| 7.30 | EOP NFSR #1929000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
V. END BRUSHING
| NFSR #1932000 | |
| 0.00 | BOP NFSR #1932000 |
I. BEGIN SURFACE MAINTENANCE
II. BEGIN SPOT SURFACING
III. BEGIN CLEAN DITCHES
| IV. BEGIN LOAD, HAUL, AND PLACE | 4.6 | 110 | 460 | 4.6 | |
| 2.60 | V. BEGIN BRUSHING | 2 | |||
| 4.60 | EOP NFSR #1932000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
III. END CLEAN DITCHES
IV. END LOAD, HAUL, AND PLACE
V. END BRUSHING
| NFSR #1932625 | |||||
| 0.00 | BOP NFSR #1932625 | ||||
| I. BEGIN INSTALL WATER BARS | 2 | INSTALL AT STAKED LOCATIONS | |||
| 1.20 | EOP NFSR #1932625 |
I. END INSTALL WATER BARS
| NFSR #1940000 | |
| 0.00 | BOP NFSR #1940000 |
I. BEGIN SURFACE MAINTENANCE
| II. BEGIN SPOT SURFACING | 7.1 | 460 | |
| 7.10 | BOP NFSR #1940000 |
I. END SURFACE MAINTENANCE
II. END SPOT SURFACING
TOTAL 121.97 8490 8,420 12 38.58 36.44 20 3.30 10 ALL
image1.png