11192 - USDA Plant Lab - As Builts REV.pdf

PDF 5 MB Posted

Attached to
Electrical Repairs for IPRL - Fort Lauderdale, FL
Solicitation number
12405B24Q0386
Issued by

About this file

This document is an as-built drawing package for the USDA Invasive Plant Research Laboratory located in Fort Lauderdale, Florida. The drawings provide detailed floor plans, reflected ceiling plans, electrical/mechanical plans, and plumbing plans for the existing facility. The drawings include key details such as room dimensions, locations of building systems, equipment, and fixtures. This as-built documentation was created based on field measurements and visual inspection of the occupied building.

The related federal contract opportunity is a solicitation for electrical repairs and upgrades to several support buildings at the Invasive Plant Research Laboratory in Fort Lauderdale, Florida. The solicitation number is 12405B24Q0386 and the NAICS code is 238210 - Electrical Contractors and Other Wiring Installation Contractors. A site visit is scheduled for July 30, 2024, and quotes are due by August 9, 2024. Award will be made based on best value to the government, considering technical capability, past performance, and price. The contract will be a firm fixed-price award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWN: REVIEWED: DATE: Sheet No:Description:THESE DRAWINGS AND RENDERINGS ARE INSTRUMENTS OF SERVICE. THE

DRAWINGS AND ASSOCIATED COPIES THEREOF, INCLUDING ELECTRONIC MEDIA

AND CADD FILES, ARE THE PROPERTY OF ARCHITECTS: LEWIS + WHITLOCK, P.A.

THEIR USE, REPRESENTATION OR REPRODUCTION IN ACTUAL OR CONTENT BY

ANY ENTITY THAT POSSESSES THEM FOR ANY PURPOSE EXCEPT BY WRITTEN

AGREEMENT WITH THE ARCHITECT IS PROHIBITED. THIS COPYRIGHT

NOTIFICATION SHALL BE TRUE AS IF DIRECTLY PLACED ON EACH DRAWING

EXHIBIT OR RENDERING ON THIS DOCUMENT AND SHALL NOT BE REMOVED

FROM THESE DOCUMENTS.

3.

Consultant:

AS-BUILT DRAWINGS

PHASE: DRAWN: REVIEWED: DATE:

U S

D A

In va si ve

P la nt R es ea rc h

La bo ra to ry

REVISIONS:

2.

5.

4.

1.

6.

FL AA0003316

architects lewis whitlock 501 east tennessee st. | suite D tallahassee. FL 32308 ph: 850 942 1718 | f: 850 942 2110 www.think3d.net

Seal:

Jo b

Ti tle

P ro je ct

P ha se

Ft . L au de rd al e, F

L

CS

C lie nt S he lto nD ea n, In c.

A s- -B ui lt

D ra w in gs

DC DC 3.25.11

PROJECT AREA

PROJECT LOCATION

STANDARD ABBREVIATIONS,

GENERAL NOTES, ARCHITECTURAL

SYMBOLS AND INDEX OF DRAWINGS

A1.1

A1.1

A1.1

A1.1

A1.1

A1.1

AS-BUILT DRAWINGS

Ft. Lauderdale, FL

AL+W Project #11192

Architectural General Notes: Index of Drawings:Legend of Architectural Symbols: Standard Abbreviations:

2) ALL DIMENSIONS ARE TO THE FACE OF STUD OR STUD TRACK, CENTER LINE OF STUD OR STUD TRACK, FACE OF MASONRY

AND TO THE CENTER LINE OF STRUCTURAL STEEL COLUMNS, UNLESS OTHERWISE INDICATED.

3) WHERE STRUCTURAL DESIGN LOADS ARE NOT PROVIDED FOR ANY COMPONENTS REQUIRING MANUFACTURER

OR FABRICATOR ENGINEERING, AND MINIMUM LOADING CONDITIONS ARE NOT PROVIDED IN APPLICABLE CODES

AND STANDARDS, CONSULT ARCHITECT PRIOR TO PROCEEDING.

13) THE CONTRACTOR SHALL ERECT AND MAINTAIN ALL REASONABLE SAFEGUARDS FOR SAFETY AND HEALTH, INCLUDING

POSTING DANGER SIGNS AND OTHER WARNING AGAINST HAZARDS, AS WELL AS PROMULGATING SAFETY STANDARDS.

4) DIMENSIONS FOR PATHS OF EGREES INCLUDING CORRIDORS AND STAIRS SHALL MEAN CLEAR WIDTH BETWEEN CORRIDOR

WALLS, AND AT STAIRS CLEAR WIDTH BETWEEN WALLS OR CURBS.

6) IF AN ORDER OF PRECEDENT FOR THE INTERPRETATION OF DOCUMENTS IS NOT PROVIDED IN THE PROJECT MANUAL (IF

PROVIDED), AND A CONFLICT OCCURS IN THE SPECIFICATIONS, ON THE DRAWINGS, OR BETWEEN THE DRAWINGS AND

SPECIFICATIONS, CONTACT THE ARCHITECT. ALL REQUEST FOR CLARIFICATION TO THE ARCHITECT SHALL BE MADE IN WRITING.

THE ARCHITECT'S RESPONSE SHALL BE MADE IN WRITING AND NO FORMAL INSTRUCTIONS SHALL BE GIVEN VERBALLY.

8) ALL FIRE RATED PARTITION OR WALL ASSEMBLIES SHALL EXTEND FROM THE FLOOR SLAB TO THE UNDERSIDE OF THE

BUILDING STRUCTURE AND/OR DECK ABOVE. ALL PENETRATIONS IN RATED CONSTRUCTION SHALL BE PROPERLY SEALED TO

INSURE THE RATING IS MAINTAINED.

15) THE CONTRACTOR SHALL MAINTAIN A CLEAN WORK PREMISE AT ALL TIMES AND SHALL CLEAN CONSTRUCTION SITE OF

ALL DEBRIS DAILY. THE WORK PREMISE SHALL BE CLEAN AT COMPLETION OF JOB AND BEFORE FINAL PAYMENT IS MADE.

9) ALL FIRE RATED FLOOR/CEILING OR ROOF/CEILING ASSEMBLIES SHALL BE CONTINUOUS BETWEEN PARTITIONS AND/OR WALLS

FOR THE SPACE OR HORIZONTAL AREA INDICATED. ALL PENETRATIONS IN RATED CONSTRUCTION SHALL BE PROPERLY SEALED

TO INSURE THE RATING IS MAINTAINED.

16) THE CONTRACTOR SHALL TAKE CARE NOT DAMAGE EXISTING SURFACES AND SHALL BE RESPONSIBLE FOR RESTORING

AREAS DAMAGED BY THE CONTRACTOR (MATERIALS, FINISHES, ETC.) TO THEIR ORIGINAL CONDITIONS. SURFACES SHALL BE

REPAINTED TO MATCH EXISTING ADJACENT FINISHES.

10) TYPICAL AND STANDARD DETAILS MAY BE PROVIDED IN THE DRAWINGS. IF A SPECIFIC DETAIL IS NOT PROVIDED

FOR CONDITION OF FABRICATION AND/OR INSTALLATION, CONTACT THE ARCHITECT PRIOR TO PROCEEDING.

11) THE INSTALLATION OF MECHANICAL, PLUMBING AND ELECTRICAL ITEMS (INCLUDING UTILITIES, ROUGH-INS, SYSTEM

COMPONENTS AND FINISHED FIXTURES) IN EXPOSED TO VIEW AREAS OR SPACES SHALL BE UNDERTAKEN WITH SKILL AND

CRAFTMANSHIP TO PROVIDE A FINISHED CONDITION ACCEPTABLE TO THE ARCHITECT. ALL EXPOSED TO VIEW ITEMS SHALL

BE FINISHED WITH PAINT UNLESS OTHERWISE SPECIFIED TO BE PREFINISHED OR NOT TO BE PAINTED.

12) THESE GENERAL NOTES HAVE THE SAME AUTHORITY AS OTHER NOTES AND REFERENCES IN THE DRAWINGS OR

SPECIFICATIONS AND SHALL NOT BE EXCLUDED IN THE EXECUTION OF THE WORK. THEY MAY REQUIRE COORDINATION

BETWEEN VARIOUS TRADE CONTRACTORS. IN ADDITION TO THESE GENERAL NOTES, REFER TO DEMOLITION AND

CONSTRUCTION NOTES SPECIFIC TO EACH DRAWING.

1) THESE DRAWINGS AND RENDERINGS ARE INSTRUMENTS OF SERVICE. THE DRAWINGS AND COPIES THEREOF, INCLUDING ELECTRONIC MEDIA AND CAD FILES, ARE THE PROPERTY OF ARCHITECTS: LEWIS + WHITLOCK, P.A. THEIR

USE, REPRESENTATION OR REPRODUCTION IN ACTUAL FORM OR CONTENT BY ANY ENTITY THAT POSSESSES THEM FOR

ANY PURPOSE EXCEPT BY WRITTEN AGREEMENT WITH THE ARCHITECT IS PROHIBITED. THE COPYRIGHT NOTIFICATION

SHALL BE TRUE AS IF DIRECTLY PLACED ON EACH DRAWING, DETAIL, EXHIBIT OR RENDERING ON THIS DOCUMENT AND

SHALL NOT BE REMOVED FROM THESE DOCUMENTS.

14) THE CONTRACTOR SHALL BE RESTRICTED TO AREAS SPECIFIED BY THE OWNER FOR ON-SITE STORAGE OF MATERIALS

5) DO NOT SCALE DRAWINGS, IF THERE IS A CONFLICT IN DIMENSIONS OR IF THERE IS INSUFFICIENT DIMENSIONING, CONTACT THE

ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING.

7) WHERE CLEAR DIMENSIONS ARE INDICATED, THIS SHALL MEAN CLEAR WIDTH FROM FINISHED WALL TO FINISHED

WALL OR CLEAR FLOOR AREA BETWEEN BUILDING COMPONENTS.

TO BREAK OFF PARTS OF DRAWING

FINISH COLOR

DEMOLITION NOTES

ALPHABETICAL

CONSTRUCTION NOTES

NUMERICAL

REVISION

DOUBLE DASHED LINE

PROPERTY LINES, BOUNDRY LINES

DASHED LINES

HIDDEN, FUTURE, OR EXIST. CONST. TO BE REMOVED

BREAK LINE

SINGLE DASH LINE

ELEVATION, SECTION

PROJECT NORTH

BUILDING SECTION REFERENCE

WALL SECTION REFERENCE

DETAIL REFERENCE

INTERIOR ELEVATION

ELEVATION REFERENCE

1A

C1

OR DETAIL IS DRAWN

SHEET NUMBER WHERE

A5.1

NUMBER INDICATES

SECTION, ELEVATION OR DETAIL

COLUMN LINES

ELEVATION

REFERENCE

POINT

DASH AND DOT

FIRE RATED WALLS

USDA Invasive Plant Research Laboratory for SheltonDean, Inc.

CS COVER SHEET

AB 1.1 AS-BUILT FLOOR PLAN, AS-BUILT REFLECTED CEILING

PLAN, LEGEND AND NOTES

AB1.2 AS-BUILT ELECTRICAL / MECHANICAL PLAN, AS-BUILT

PLUMBING PLAN, LEGENDS AND NOTES

March 25, 2011

Area Map

-AIR CONDITIONING

-AMERICAN CONCRETE INSTITUTE

-ACOUSTICAL CEILING TILE

-ADJACENT

-ABOVE FINISH FLOOR

-ALTERNATE

-ALUMINUM

-AMERICAN SOCIETY OF TSTG. & MTLS.

-BOARD

-BUILDING

-BOLT

-BEAM

-BOTTOM

-BEARING

-CENTER TO CENTER

-CEMENT

-CUBIC FEET

-CUBIC FEET PER MINUTE

-CORNER GUARD

-CIRCLE, CIRCULAR

-CAST-IN-PLACE

-CONTROL JOINT

-CEILING

-CLOSET

-CLEARANCE, CLEAR

-CONCRETE MASONRY UNIT

-COLUMN

-COMPRESSOR, COMPOSITE

-CONCRETE

-CONSTRUCTION

-CONTINUOUS

-CORRUGATED

-COUNTERSINK

-CENTER

-DOUBLE

-DIRECT APPLIED EXT FINISH SYSTEM

-DEGREES

-DETAIL

-DRINKING FOUNTAIN

-DIAMETER

-DIMENSION

-DOWN

-DOWNSPOUT

-DETAIL

-DRAWING

-EACH

-EXPANSION JOINT

-ELECTRICAL

-ELEVATOR, ELEVATION

-ENCLOSURE

-EQUAL

-EQUIPMENT

-ELECTRICAL WATERCOOLER

-EXHAUST

-EXISTING

-EXTERIOR

A/C

ACI

ACT

ADJ

AFF

ALT

ALUM

ASTM

BD

BLDG

BLT

BM

BOT

BRG

C/C

CEM

CF

CFM

CG

CIR

CIP

CJ

CLG

CLO

CLR

CMU

COL

COMP

CONC

CONSTR

CONT

CORR

CS

CTR

DBL

DEFS

DEG

DTL

DF

DIA

DIM

DN

DS

DTL

DWG

EA

EJ

ELEC

ELEV

ENCL

EQ

EQUIP

EWC

EXH

EX

EXT

FD

FEB

FEC

FF

FHC

FIN

FL

FLG

FT

FTG

GA

GALV

GEN

GND

GWB

GYP

HC

HDR

HDRL

HM

HORZ

HGT

ID

IN

INSUL

INT

JAN

JB

JT

K

KD

L

LAM

LAV

LBS

LH

LL

LLH

LLV

LTL

LTWT

LVR

-FLOOR DRAIN

-FIRE EXTINGUISHER W/ BRACKET

-FIRE EXTINGUISHER IN CABINET

-FINISH FLOOR

-FIRE HOSE CABINET

-FINISH

-FLOOR

-FLASHING

-FOOT OR FEET

-FOOTING

-GAUGE

-GALVANIZED

-GENERAL

-GROUND

-GYPSUM WALLBOARD

-GYPSUM

-HANDICAPPED ACCESSIBLE

-HEADER

-HANDRAIL

-HOLLOW METAL

-HORIZONTAL

-HEIGHT

-INSIDE DIAMETER (DIM.)

-INCHES

-INSULATION

-INTERIOR

-JANITOR

-JAMB

-JOINT

-KIPS (KILO POUND OR 1000LBS.)

-KILN DRIED

-STEEL ANGLE, LENGTH

-LAMINATED

-LAVATORY

-POUNDS

-LEFT HAND

-LIVE LOAD

-LONG LEG HORIZONTAL

-LONG LEG VERTICAL

-LINTEL

-LIGHTWEIGHT

-LOUVER

M

MATL

MAX

MC

MECH

MTL

MEZZ

MFR

MIN

MISC

MK

MO

MTD

MULL

N

NA

NIC

NOM

NS

NTS

OA

OC

OD

OH

OPP

OPPH

PCF

PKG

PL

PLAM

PLYWD

PNL

PR

PREFAB

PREP

PSF

PSI

PT

PVC

PVMT

QC

QT

REF

REINF

REQD

REV

RH

RM

RO

-METER

-MATERIAL

-MAXIMUM

-MEDICINE CABINET

-MECHANICAL

-METAL

-MEZZANINE

-MANUFACTURER

-MINIMUM

-MISCELLANEOUS

-MARK

-MASONRY OPENING

-MOUNTED

-MULLION

-NORTH

-NOT APPLICABLE

-NOT IN CONTRACT

-NOMINAL

-NON SHRINK

-NOT TO SCALE

-OVERALL

-ON CENTER

-OUTSIDE DIAMETER

-OVERHEAD

-OPPOSITE

-OPPOSITE HAND

-POUNDS PER CUBIC FOOT

-PARKING

-PLATE

-PLASTIC LAMINATE

-PLYWOOD

-PANEL

-PAIR

-PREFABRICATED

-PREPARATION

-POUNDS PER SQUARE FOOT

-POUNDS PER SQUARE INCH

-PRESSURE TREATED, PAINT, POINT

-POLYVINYL CHLORIDE

-PAVEMENT

-QUALITY CONTROL

-QUARRY TILE

-REFERENCE

-REINFORCED, REINFORCEMENT

-REQUIRED

-REVISION

-RIGHT HAND

-ROOM

-ROUGH OPENING

SAN

SC

SECT

SEW

SF

SGL

SIM

SJ

SPKLR

SQ

SST

STD

STL

STOR

STRUCT

SUSP

TBD

TEL

TEMP

T&G

THK

TOB

TOC

TOF

TOS

TS

TV

TYP

UNF

UON

UR

VCT

VB

VERT

VEST

VFY

VOL

VT

W/ W/C

WD

W/O

WP

WWF

-SANITARY

-SOLID CORE

-SECTION

-SEWER

-SQUARE FEET

-SINGLE

-SIMILAR

-SAWED JOINT

-SPRINKLER

-SQUARE

-STAINLESS STEEL

-STANDARD

-STEEL

-STORAGE

-STRUCTURAL

-SUSPENDED

-TO BE DETERMINED

-TELEPHONE

-TEMPORARY, TEMPERATURE

-TONGUE & GROOVE

-THICK

-TOP OF BEAM

-TOP OF CONCRETE

-TOP OF FOOTING

-TOP OF STEEL

-STRUCTURAL TUBE STEEL

-TELEVISION

-TYPICAL

-UNFINISHED

-UNLESS OTHERWISE NOTED

-URINAL

-VINYL COMPOSITION TILE

-VAPOR BARRIER

-VERTICAL

-VESTIBULE

-VERIFY

-VOLUME

-VINYL TILE

-WITH

-WATER CLOSET

-WOOD

-WITHOUT

-WATERPROOF, WORKING POINT

-WELDED WIRE FABRIC

Location Map

NORTH

NORTH

DRAWN: REVIEWED: DATE: Sheet No:Description:THESE DRAWINGS AND RENDERINGS ARE INSTRUMENTS OF SERVICE. THE

AND CADD FILES, ARE THE PROPERTY OF ARCHITECTS: LEWIS + WHITLOCK, P.A.

THEIR USE, REPRESENTATION OR REPRODUCTION IN ACTUAL OR CONTENT BY

ANY ENTITY THAT POSSESSES THEM FOR ANY PURPOSE EXCEPT BY WRITTEN

AGREEMENT WITH THE ARCHITECT IS PROHIBITED. THIS COPYRIGHT

NOTIFICATION SHALL BE TRUE AS IF DIRECTLY PLACED ON EACH DRAWING

EXHIBIT OR RENDERING ON THIS DOCUMENT AND SHALL NOT BE REMOVED

FROM THESE DOCUMENTS.

3.

Consultant:

AS-BUILT DRAWINGS

PHASE: DRAWN: REVIEWED: DATE:

U S

D A

In va si ve

P la nt R es ea rc h

La bo ra to ry

REVISIONS:

2.

5.

4.

1.

6.

FL AA0003316

architects lewis whitlock 501 east tennessee st. | suite D tallahassee. FL 32308 ph: 850 942 1718 | f: 850 942 2110 www.think3d.net

Seal:

Jo b

Ti tle

P ro je ct

P ha se

Ft . L au de rd al e, F

L

AB1.1

C lie nt S he lto nD ea n, In c.

A s- -B ui lt

D ra w in gs

DC DC 3.25.11

PLAN

NORTH

'-3

142'-2"

'-3

7'-

1/ 4"

9'-

3/

3'-

0" 3'-

5 1 /2"

5'-

9'-

5'-

142'-2" 16'-7" 3'-0" 15'-7" 3'-0" 9'-0" 3'-0"

1'-8 1/2" 3'-0" 12'-2" 3'-0" 21'-0" 3'-0" 3'-2 1/2" 3'-0" 32'-11" 3'-0" 6'-0"

7'-11" 3'-0" 5'-8" 3'-0" 15'-7" 3'-0" 6'-4 5/8" 3'-0" 6'-4" 3'-0" 11" 3'-0" 5'-4 1/4" 8'-0" 13'-6 1/2" 3'-0" 5'-11" 3'-0" 36'-5" 3'-0" 6'-1"

1'- 1"

3'- 4"

'-8

3'-

0" 6'-

2"

'-4

8 1 /2"

44'-10 1/2"

10'-9 1/2" 5'-6 1/2" 11'-1"

4'- 8 1

/2"

'-7 1/

2"

EQ

EQ

EQ

9'- 6 1

/2"

9'-3 1/2"

18'-10" 1'-1 3/4" 10'-4 1/2" 11 3/4" 8'-8"

3'- 1"

1'- 3 3

/4"

8 3/4"

40'-0"

'-9

7 1 /2"

7 1 /2"

11'-6 1/2"

'-4

27'-5"

4'- 4 3

/4"

9"

18'-10" 1'-1 3/4" 20'-0 1/4"

'-0

3'- 0 1

/2"

13'-9"

'-8

1'- 0"

2'-0" AFF

ACCESS PANELACCESS PANEL

CLEAN OUT

HOSE BIBB

THIS DOOR ABANDONED - PERIMETER

SEALED WITH DRYWALL INFILL ON

INTERIOR OF OPENING

THIS DOOR ABANDONED -

PERIMETER SEALED WITH

DRYWALL INFILL ON INTERIOR

OF OPENING

THIS DOOR ABANDONED - PERIMETER SEALED

WITH DRYWALL INFILL ON INTERIOR OF

OPENING

CONC. LOADING DOCK

METAL HANDRAIL

CONC. STEPS

CONCRETE RAMP

CONC. STOOP

ASPHALT RAMP

UTILITY PIT W/

STL. PLATE

COVER

ELECTRIC SERVICE / METER

HOSE BIBB

FLOOR DRAIN

FLOOR DRAIN

FLOOR DRAIN - FROM SINKSFLOOR DRAIN

ELECTRIC SERVICE / METER

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

TAPERED METAL COLUMN - TYP.

LAB SINK - TYP. OF 3

BUILT-IN STORAGE UNIT

ASPHALT PAVINGASPHALT PAVING

ASPHALT PAVINGASPHALT PAVING ASPHALT PAVINGASPHALT PAVING UTILITY PIT W/

STL. PLATE

COVER

TELE/COM PANEL

ELEC. PANEL

3" DIA. CONDUIT

THRU FLOOR

CONC. SIDEWALK CONC. SIDEWALK

COMMERCIAL METAL SINK

AND WORKTOP

COMMERCIAL METAL SINK

AND WORKTOP

ELEC. PANELELEC. PANEL

METAL STORAGE

ENCLOSURE

METAL STORAGE

ENCLOSURE

BUILT-IN LAB

WORKSTATION

- TYP.

BUILT-IN LAB

WORKSTATION

- TYP.

MODULAR

WORKSTATION

- TYP.

TILE SHOWER

3' -0

"x 3'

-0

S

IL

L@

" A

FF

3'-0"x3'-0"

SILL@48" AFF

3'-0"x3'-0"

SILL@48" AFF

3'-0"x3'-0"

SILL@48" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@48" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@60" AFF

3'-0"x3'-0"

SILL@48" AFF

3'-0"x3'-0"

SILL@48" AFF

WH

DW

3'-0"x7'-0"

9"

REF

3'-0"x7'-0"

REF

3'-0"x7'-0"

3' -0

"x 7'

-0

2'- 4" x7 '-0

EAST LAB

STORAGE

RR

WET LAB

CHAMBER

ROOM

WEST LAB

3'-6"x7'-0"

3' -0

"x 7'

-0

PA

IR

4' -0

"x 7'

-0

REF

3'-0"x6'-8"

REF

PAIR

4'-0"x7'-0"

REF

REF

REF

REF

REF

REF

REF

REF

HEAT

PUMP

HEAT

PUMP

WHREF

DUCT

SLOPE

6"

8-1/2"

2-1/2"

S

LO

P E

HVAC

UNIT

HVAC

UNIT

NOTE: AS -BUILT DRAWINGS ARE BASED SOLELY ON

FIELD MEASUREMENT AND VISUAL INSPECTION OF

THE EXISTING OCCUPIED BUILDING. FIELD

MEASUREMENT WAS DONE ON 3/15/11 - 3/16/11.

PLAN

NORTH

GYPSUM BULKHEAD

GYPSUM BULKHEAD

2X2 AIR DIFFUSER - SUPPLY - TYP.

2X4 FLUORESCENT LIGHT FIXTURE - TYP.

2X2 AIR DIFFUSER - RETURN - TYP.

EXIT LIGHT - TYP.

EXHAUST FAN - TYP.

1X4 FLUORESCENT LIGHT

FIXTURE - TYP.

ATTIC ACCESS HATCH - TYP.

6" DIA. RECESSED CAN LIGHT - TYP.

EAST LAB

STORAGE

RR

WET LAB

CHAMBER

ROOM

WEST LAB

8'-0" CLG. 8'-8" CLG. 8'-5" CLG.

8'-0" CLG.

7'-10 1/2" CLG.

8'-3 1/2" CLG.

NOTE: AS -BUILT DRAWINGS ARE BASED SOLELY ON

FIELD MEASUREMENT AND VISUAL INSPECTION OF

THE EXISTING OCCUPIED BUILDING. FIELD

MEASUREMENT WAS DONE ON 3/15/11 - 3/16/11.

2X4 FLUORESCENT LIGHT FIXTURE - RECESSED

2X2 FLUORESCENT LIGHT FIXTURE - SURFACE MT.

ATTIC ACCESS HATCH

EXIT LIGHT

6" DIA. RECESSED CAN LIGHT

EXHAUST FAN

AIR DIFFUSER - SUPPLY

AIR DIFFUSER - RETURN

GYPSUM CEILING

ACOUSTIC CEILING TILE AND GRID

1 As-Built Floor Plan 3/16" = 1'-0"

As-Built Reflected Ceiling Plan 3/16" = 1'-0"

RCP Legend

AS-BUILT FLOOR PLAN, AS-BUILT

REFLECTED CEILING PLAN, LEGEND

AND NOTES

DRAWN: REVIEWED: DATE: Sheet No:Description:THESE DRAWINGS AND RENDERINGS ARE INSTRUMENTS OF SERVICE. THE

AND CADD FILES, ARE THE PROPERTY OF ARCHITECTS: LEWIS + WHITLOCK, P.A.

THEIR USE, REPRESENTATION OR REPRODUCTION IN ACTUAL OR CONTENT BY

ANY ENTITY THAT POSSESSES THEM FOR ANY PURPOSE EXCEPT BY WRITTEN

AGREEMENT WITH THE ARCHITECT IS PROHIBITED. THIS COPYRIGHT

NOTIFICATION SHALL BE TRUE AS IF DIRECTLY PLACED ON EACH DRAWING

EXHIBIT OR RENDERING ON THIS DOCUMENT AND SHALL NOT BE REMOVED

FROM THESE DOCUMENTS.

3.

Consultant:

AS-BUILT DRAWINGS

PHASE: DRAWN: REVIEWED: DATE:

U S

D A

In va si ve

P la nt R es ea rc h

La bo ra to ry

REVISIONS:

2.

5.

4.

1.

6.

FL AA0003316

architects lewis whitlock 501 east tennessee st. | suite D tallahassee. FL 32308 ph: 850 942 1718 | f: 850 942 2110 www.think3d.net

Seal:

Jo b

Ti tle

P ro je ct

P ha se

Ft . L au de rd al e, F

L

AB1.2

C lie nt S he lto nD ea n, In c.

A s- -B ui lt

D ra w in gs

DC DC 3.25.11

SDSD

SD

PLAN

NORTH

TTSD

SD

INDOOR UNIT SPLIT SYSTEM #5INDOOR UNIT SPLIT SYSTEM #4INDOOR UNIT SPLIT SYSTEM #3

BLANK FACE PLATE

BLANK FACE PLATE

BLANK FACE PLATE

BLANK FACE PLATE

INDOOR UNIT SPLIT SYSTEM #2

INDOOR UNIT SPLIT SYSTEM #1

OUTDOOR UNIT SPLIT SYSTEM #5OUTDOOR UNIT SPLIT SYSTEM #4OUTDOOR UNIT SPLIT

SYSTEM #3

OUTDOOR UNIT SPLIT SYSTEM #2

OUTDOOR UNIT SPLIT SYSTEM #1

UTILITY PIT W/

STL. PLATE

COVER

UTILITY PIT W/

STL. PLATE

COVER

ELEC. METER / SERVICEELEC. METER / SERVICE

ELEC. PANELELEC. PANEL

ELEC. PANEL

TELE/COM PANEL

3" DIA. CONDUIT -

THRU FLOOR

2" CONDUIT

ALARM

KEYPAD

JUNCTION BOX WIRED TO MODULAR FURNITURE

HOSE BIBB

HOSE BIBB

CLEAN OUT

ACCESS PANELACCESS PANEL

WH

DW

REF

REF

EAST LAB

STORAGE

RR

WET LAB

CHAMBER

ROOM

WEST LAB

REF

REF

REF

REF

REF

REF

REF

REF

REF

REF

HEAT

PUMP

HEAT

PUMP

WHREF

DUCT

SLOPE

S

LO

P E

GFI

29-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

42-1/2"

6'-4" AFF6'-5" AFF6'-5" AFF

47"

47"

47"

47"

47"

47"47"

47"

GFI

27"

66"S

66"

34"S

66"S

34"S

66"S

34"S

66"S

34"S

S

S34" 66"

220V

27" 54"

SMSM

54"54"

18"

SM/220V

46"

50"

50"

50" 50"

GFI

6'-8" AFF

6'-8" AFF

66"S 66"S66"S

34"S 34"S34"S 66"

HVAC

UNIT

HVAC

UNIT

250V

250V

SM

SM

SM

220V

SM

SM

SM

52"

52"

250V

58"

58"

58"

58"

58"

58"

58"

58"

SM

18" 18"18"18" 18"18"

WP

NOTE: AS -BUILT DRAWINGS ARE BASED SOLELY ON

FIELD MEASUREMENT AND VISUAL INSPECTION OF

THE EXISTING OCCUPIED BUILDING. FIELD

MEASUREMENT WAS DONE ON 3/15/11 - 3/16/11.

BLANK FACE PLATE

SD

T

WH

GFI

WP

S

S

SM

220V

250V

NOTE: DIMENSION

SHOWN (EXAMPLE: 18")

ADJACENT TO DEVICES

INDICATES MOUNTING

HEIGHT AFF TO

CENTERLINE OF

DEVICE.

SWITCH

DOUBLE SWITCH

DUPLEX RECEPTACLE

SMOKE DETECTOR

WATER HEATER

BLANK FACE PLATE

DUAL RECEPTACLE - GFI

TELE/COM OUTLET

QUAD RECEPTACLE

DUAL RECEPTACLE - WP

DUPLEX RECEPTACLE - SWITCHABLE

SINGLE RECEPTACLE - SWITCHABLE

JUNCTION BOX

QUAD RECEPTACLE - SURFACE MOUNT

DUAL RECEPTACLE - 220V

THERMOSTAT

DUAL RECEPTACLE - 250V

SM

DUAL RECEPTACLE - SURFACE MOUNT

PLAN

NORTH

3" VENT - THRU ROOF

SEDIMENT TRAP

COLD WATER

FEED (OVERHEAD)

WATER LINE UNDER SLAB THIS LOC.WATER LINE UNDER SLAB THIS LOC.

WH

DW

REF

REF

EAST LAB

STORAGE

RR

WET LAB

CHAMBER

ROOM

WEST LAB

REF

REF

REF

REF

REF

REF

REF

REF

REF

REF

HEAT

PUMP

HEAT

PUMP

WHREF

DUCT

SLOPE

S

LO

P E

HVAC

UNIT

HVAC

UNIT

NOTE: AS -BUILT DRAWINGS ARE BASED SOLELY ON

FIELD MEASUREMENT AND VISUAL INSPECTION OF

THE EXISTING OCCUPIED BUILDING. FIELD

MEASUREMENT WAS DONE ON 3/15/11 - 3/16/11.

CO

FD

FD

FD

CO CO

CO

FD

HB

HB

WH

FD

CO

WATER HEATER

CLEAN OUT

FLOOR DRAIN

SANITARY SEWER LINE

HOT WATER LINE

COLD WATER LINE

HB HOSE BIBB

1 As-Built Elec/Mech Plan 3/16" = 1'-0"

Elec/Mech Legend

2 As-Built Plumbing Plan 3/16" = 1'-0"

Plumbing Legend

AS-BUILT ELECTRICAL /

MECHANICAL PLAN, AS-BUILT

PLUMBING PLAN, LEGENDS AND

NOTES

CS Cover Sheet
AB1.1 Floor Plan _ RCP.PDF
AB1.1 Floor Plan / RCP
AB1.2 Elec_Mech Plan.PDF
AB1.2 Elec/Mech Plan

File details come from the government source that posted it. Updated .