Asbestos Reports.pdf

PDF 5 MB Posted

Attached to
Remove Existing & Construct New Greenhouse Federal contract opportunity
Solicitation number
12405B21R0009
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery

About this file

This document includes a limited asbestos survey report and a federal contract opportunity solicitation. The asbestos survey report identifies asbestos containing materials found in various areas of two buildings on the USDA Agricultural Research Service property in Mississippi State, MS, including floor tile and mastic, thermal system insulation, and a transite flue vent pipe. It provides recommendations and notes that an asbestos abatement project will be required.

The federal contract opportunity solicitation is an 8(a) set-aside requesting proposals to remove an existing greenhouse and construct a new greenhouse at the USDA Agricultural Research Service Crop Science Research Laboratory in Mississippi State, MS. Interested contractors must attend a mandatory site visit by a specified date and submit proposals by 2:00pm Central on May 3, 2021. Proposals should include pricing breakdowns and be emailed to the points of contact listed. The solicitation will be amended to include site visit details. Questions are due by April 16, 2021.

View the file

Other files for this federal contract opportunity

Other files attached to Remove Existing & Construct New Greenhouse, newest first.
File Type Posted
Amendment 004 - 12405B21R0009.pdf PDF
Attachment IV - Davis Bacon Wage Determination - Oktibbeha County - Updated April 23 2021.pdf PDF
Amendment 003 - 12405B21R0009.pdf PDF
Photographs.pdf PDF
Amendment 002 - 12405B21R0009.pdf PDF
Site Visit Sign-In Sheets.pdf PDF
Attachment III - Construction RFP Provisions - Updated April 20 2021.pdf PDF
Attachment VII - Past Performance Questionnaire (PPQ) - Blank - Updated April 20 2021.docx DOCX document
Q-A Doc Ms. State Greenhouse - April 20 2021.pdf PDF
Attachment III - Construction RFP Provisions - Updated April 06 2021.pdf PDF
Amendment 001 - 12405B21R0009.pdf PDF
Attachment I - Final Specifications Demo and Construct Greenhouse - Mississippi State MS.pdf PDF
Attachment II - Final Drawings Demo and Construct Greenhouse - Mississippi State MS.pdf PDF
Attachment V - Certified Cost and Pricing Data Form - Blank.pdf PDF
Attachment VI - FAR 52.204-24 Declaration.pdf PDF
Request for Proposal - 12405B21R0009.pdf PDF
Attachment IV - Davis Bacon Wage Determination - Oktibbeha County.pdf PDF
Attachment VII - Past Performance Questionnaire (PPQ) - Blank.docx DOCX document
Attachment III - Construction RFP Provisions.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

rild•&IH•lii!IBtiii-liii.Lifu--iiifiA4◄Hii

PHONE: (001)940-4641 FAX:601-354-3133

P.O. Bol 16891 } \l.

JACKSON, 5 39236 ct ) 6 SJ}

USDA ARS

R.W. HARNED BIUILDING - B001

I

HEADHOUSE/GREENHOUSE- B002

s10 HIGHwlv 12 EAST

MISSISSIPPI STATE, MISSISSIPPI 39762

11t-@ii•t1■4Mii-HH.laa1¥1iii@•11A

PHONE: (001)940-4644 FAX:601-354-3133

P. 0 . Bo 16891

JACKSON, S 39236

LIMITED ASBESTOS ATERIAL SURVEY

Submit ed to:

Margi I Cook

Administra ive Officer Mississippi State, MS

Renovatio Property:

R.W. Harn .d Building

810 Hwy. 12 East - ississippi State, MS 8001 8002

Report prrared by:

Paul D. ~~derson

MS Certif~e:. :~{~~o;~nspector

ANDERSON ENVIRO~ MENTAL SERVICES

P.O. BOf 16891

JACKSON, IMS 39236

SEPTEMB R 5, 2017

TABLE OF 10NTENTS

ASBESTOS CERTIFICATION

1.0 INTRODUCTION

1.1 Authority

1.2 Work Performed

2.0 DEFINITIONS

3.0 METHODS

3.1 Field Survey

3.2 Laboratory Analysis

4.0 SURVEYS (INCLUDES BUILDINGS TESTED, BULK SAMPLE ANALYSIS, ESTIMATED

QUANTITIES & LAB REPORTS)

4.1 R.W. Harned Building (BOOl & BO 2)-810 Hwy. 12 East - Mississippi State, MS

5.0 CONCLUSION

6.0 LIMITATIONS

Project:

Date:

ASBESTOS INSPE

TION REPORT

CERTIFI 1ATION

USDA - ARS R. W. Harned Bl g. - 810 Hwy. 12 East - Renovation Project - (B001 & B002) - Mi sissippi State, MS

September 5, 2017

I hereby certify this report constitutes an accur~te presentation of a limited asbestos material survey, sample collection, and analysis conducted for 810 Highway 12 East in Mississippi State, Mississippi and their duly authorized rep esentative with the USDA - ARS to determine the presence and location of suspect asbestos-c ntaining materials.

Date 9/5/17

Paul Anderson lnsP,ector Cert fication No. ABl-00001686 Exp. 7/15/18

I have examined this report and hereby certify he accuracy and acceptability of its contents

EXECUTIVE SUMMARY:

Project: R.W. Harned Building- (B00l & 002)- Mississippi State, MS

Anderson Environmental was hired to conduct l n asbestos survey for the project listed above. Based on the asbestos inspection and subsequent lab results, Asbestos Containing

Materials (ACM) were detected. l

- 9 x 9 floor tile & black mastic througho t the ground floor of the structure - B00l.

- 9 x 9 floor tile & black mastic located i'1 storage area & lab in headhouse.

- All Thermal System Insulation (TSI) sh9uld be treated as Asbestos Containing

Material (ACM). This does not include lack brittle material with the silver foil (FART

ROCK).

- *****NOTE: AN ASBESTOS CONTAIN! G TRANSITE FLUE (VENT PIPE) EXTENDS FROM

BOILER TO PIPE, CAN BE LOCATED AT HE HEADHOUSE MECHANICAL ROOM.*****

RECOMMENDATIONS:

Please review the entire report for a full break own of the Survey.

111111

SEPTEMBER 5, 2017

PAUL D. ANDERSON

Industrial Hygienist/ Inspector

1.0 INTRODUCTION

1.1 Authority

On August 25, 2017, Anderson Environmental S rvices began conducting a limited asbestos material survey for the R.W. Harned Building co tracted. It's located at 810 Hwy. 12 East in

Mississippi State, Mississippi. The survey was p rformed to determine the presence and location of suspect asbestos containing materia (ACM) for the ground floor of Building 001 and the Headhouse areas of Building 002. The Jork was authorized by Ms. Margie Cook to provide asbestos inspection services for renovaj ion of the properties at Buildings: 1 & 2. The survey was performed by a Certified Asbestos I spector Paul Anderson MDEQ # ABI- 1686, Expiration 7/15/2018.

1.2 Work Performed

As outlined in the initial scope of services, I con ucted the following:

Step 1:

Preliminary walk-through and inspection of all ccessible & affected areas within the structures for the purpose of locating and docu.lnenting suspect ACM.

Step 2:

Development and implementation of a samplin scheme for all suspect ACM.

Step 3:

Performance of quality-assured analysis of the ulk samples obtained during the inspection, using polarized light microscopy (PLM).

Step 4:

Preparation and submission of this report.

a. Listing of all sampled homogeneous a eas suspected of ACM and all known ACM's based on the sample analysis

b. Listing of estimated quantities of confirmed ACM's

c. Observations and recommendation

d. Results from the sample analysis

2.0 DEFINITIONS

ABATEMENT-The removal, repair, encapsulatio

, or enclosure of ACM.

ASBESTOS- The asbestiform varieties of chrysot1·1e, crocidolite, amosite, anthophylite, tremolite and actinolite.

ASBESTOS CONTAINING MATERIAL {ACM)- any [ aterial which contains more than one percent asbestos by volume.

COMPOSITE SAMPLE- A bulk sample of suspect omogeneous building material that consist of a mixture of equal quantities of the material bollected from various locations within a homogenous or functional sampling area.

ENCAPSULATION- The application of a coating to friable or nonfriable asbestos to prevent release.

ENCLOSURE- The construction of an air-tight ba rier around friable and nonfriable asbestos to prevent fiber release.

FRIABLE- The condition of any ACM which whe dry may be crumbled or reduced to powder by hand pressure.

FUNCTIONAL SPACE- A room or specific area.

HOMOGENEOUS AREA- An area of surfacing m terial, thermal system insulation, or miscellaneous material that is uniform in textu, e and color and appears identical in every other respect including relative date of insulaticl>n.

HOMOGENEOUS MATERIAL- A material which + ay or may not extend through many areas, is uniform in color and texture and appears ident cal in all other respects, including relative date of installation.

HVAC- System and/or component equipment a sociated with the heating, ventilation and air conditioning of a building

MISCELLANEOUS MATERIAL-A classification for suspect ACM such as resilient floor coverings, acoustical ceiling tile, transite products, etc.

OPERATION AND MAINTENANCE PLAN (O&M)- set of procedures undertaken to clean up previously released asbestos fibers, prevent fut111re release of fibers by minimizing disturbance of damage to ACM, monitoring the I ondition of the ACM and retain all documentation relating to asbestos within the uilding.

POLARIZED LIGHT MICROSCOPY (PLM)- Method used to estimate the percent of asbestos by volume in a bulk sample.

REMOVAL- Removal of the ACM and replaceme t with a non asbestos-containing mater ial to provide the same function and fire rating, unless the removal is for the purpose of demolition.

RESPONSE ACTION- A method including remov~I, encapsulation, enclosure, repair, operation and maintenance that protects human health ar the environment from friable ACM.

SURFACING MATERIAL- A classification of suspe!ict ACM which is applied to walls, ceilings, or structural members by a sprayed-on, troweled-bn method such as fireproofing or decorative applications.

SUSPECT MATERIAL-A type of building component that is known, or has been known to contain asbestos minerals.

THERMAL SYSTEM INSULATION (TSI)- A classification of suspect ACM which covers piping, boilers, HVAC components, etc., to act as an inJulator, not as a coating or sealant.

3.0 METHODS

3.1 Field Survey

The survey procedure consisted of a complete visual and walk-through of the damaged areas and inspection of accessible interior & exterior surfaces, and subsequent formulation of a sampling scheme. Flooring, walls, domestic syst~m components, water heating systems and other interior surfaces were examined for the p~esence of ACM. The survey was conducted by

MDEQ certified asbestos inspector Paul AndersJn (MDEQ Certification #ABI- 1686).

All suspect materials were touched to determln~ their friablllty. If these materials could be broken and/or crumbled by hand pressure, it wfs deemed friable. Random and judgmental samples were collected from suspect materials throughout the structures. Survey and sampling procedures and protocols were condur ed in accordance with U.S. Environmental

Protection Agency (USEPA) specifications and recommendations, 40 CFR 763.107 - 763.109, 40 CFR 763.85 - 763.88, 1987, and EPA manuals r 5/2-78-014 (part 1 and II) and 560/5-85-024.

The Asbestos Hazard Emergency Response Act (IAHERA), 40 CFR 763, guidelines are considered by most regulatory agencies, USEP I and the Occupational Safety and Health

Administration (OSHA) to be state of the art fo conducting asbestos inspections and assessments.

3.2 Laboratory Analysis

Bulk samples of suspect homogeneous ACMs ere collected during the inspection and subsequently submitted to Environmental Hazards Services L.L.C. located in Richmond, Virginia to determine the presence of asbestos lminerals. The EPA recommended method of polarized light microscopy (PLM) and dispersion staining was used to determine the presence of type and contents.

4.1 R.W. Harned Bldg. (8001 & 8002)- Mississippi State, MS

BULK SAMPLE SUMMARY l Category: M-Miscellaneous, S-Surfacing, TSI-Ther al System Insulation, TJC-Tape Joint

Compound (K-KITCHEN, LR-LIVING RM, BR-BEDRI ,1, RR-RESTROOM, H-HALL, 0-DEN, P-PORCH, DR-DINING ROOM)

SAMPLE DESCRIPTION AND LOCATION ASBESTOS CATEGORY

NUMBER DETECTED

**** HEADHOUSE/GREENHOUSE - 8002

01 Pipe Joint Insulation - Boiler room YES TSI

02 Pipe Insulation - Boiler room YES TSI

03 Pipe Insulation - Boiler room YES TSI

04 Boiler Insulation - Boiler Interior YES TSI

OS Pipe Insulation- Boiler room YES TSI

06 Pipe Insulation - Boiler room YES TSI

07 Pipe Insulation - Boiler room YES TSI

08 Pipe Insulation - Boiler room YES TSI

09 Pipe Insulation - Boiler room YES TSI

010 Pipe Joint Insulation - Greenhouse arr a YES TSI

~ 011 12 x 12 floor tile - Storage area YES M

012A 12 x 12 floor tile - Lab area YES M

012B Mastic beneath sample 012A NAO M

012( 12 x 12 floor tile - Lab area YES M l 0120 Mastic beneath sample 012C NAO M

013 Pipe Insulation - Restroom (Fart Roel )(Black) NAO TSI

014 Pipe Insulation (Fart Rock)(Black) NAO TSI

-**** R.W. HARNED BUILDING 001- GROU~ D

~'o

FLOOR

015A 9 X 9 floor tile - West entry hall (Tan) YES M

015B Mastic beneath sample 015A YES M

· ~ 016 Covebase (Black) NAO M t<v~ 017A 9 x 9 floor t ile- Room C-22 (Olive grSen) YES M ~ I

0178 Mastic beneath sample 017A YES M

018A 9 x 9 floor tile - East hall {Tan/Green) YES M

018B Mastic beneath sample 018A YES M

NAO-NO ASBESTOS DETECTED

AREAS OF ASBESTOS FLOORING - GROUND FLOOR - B001

1,l, . ~ tleaJfil)ll5e/ JP'Q t}tfrl1Ao!ISB

AREAS OF ASBESTOS THERMAL SYSTEM INSULAT ON IN HEADHOUSE/GREENHOUSE B002:

ALL POSITIVE ACM SAMPLES ARE NOT PICTURED FOR B002

5.0 SUMMARY/CONCLUSION:

5.1 FINDINGS:

Based on the asbestos inspection and subseque t lab results, Asbestos Containing Materials

(ACM} were detected.

9 x 9 floor tile throughout GROUND FLO R of B00l

9 x 9 floor tile located in storage & lab a1ea of B002.

All THERMAL SYSTEM INSULATION locat din B002 should be considered ACM. This does not include (Fart Rock}.

******REMEMBER Transite Vent pipe extending from boiler should be assumed as

ACM.*******

5.2 RECOMMENDATIONS:

1. Prior to any renovation that may disturb the positive Asbestos Containing Materials, asbestos abatement plans and guideline specific~tions should be developed. The asbestos abatement actions (removal) should be accomp~· shed by an accredited and licensed asbestos abatement contractor and in a manner prescrib d by the Environmental Protection Agency

(EPA) Regulation 40 CFR parts 61.145 and 61.15 , and Occupational Safety and Health

Administration (OSHA), standard 29 CFR 1926.1~01. All work shall be conducted following

NESHAP removal guidelines. A 10 day removal/~emolition notification must be filed with the

Mississippi Department of Environmental QualitI (MDEQ). This can be filed by anyone familiar with the MDEQ guidelines for filing.

2. All asbestos abatement personnel should hav received proper training as required for certification of asbestos workers or supervisors • y the State of Mississippi.

3. Contractor shall obtain necessary permits an state license in conjunction with asbestos removal, hauling, and disposition, and furnish tifely notification of such actions required by federal, state, regional, and local authorities. N1tify the Mississippi Bureau of Pollution

Control, Air Division and the Environmental Engreer in writing 10 days prior to the commencement of work in accordance with 40 1 FR 61, Subpart M as mentioned in section 1

6.0 LIMITATION

This report has been prepared for the exclusive se for USDA -ARS in Mississippi State, MS and any other duly selected representative for t~e specific application to pending structure renovation. Copies of our report may be distribu~ed provided their use is consistent with the intent of our services. Our findings have been der eloped in accordance with generally accepted standards of practice, direct observati~ns of the designated areas made during the surveying period, available information, and ourlprofessional judgement. No other warranty is expressed or implied. The client recognizes that future changes in future use and construction within the building may affect the conclusions/fihdings presented in this report.

This report applies only to the samples analyzed The liability of Anderson Environmental

Services is limited to the amount paid for this re ort by the client. The client assumes all liability for the further distribution of this report or its contents and by making such distribution agrees to hold Anderson Environme tal Services harmless against all claims of persons so informed of the contents thereof.

It is intended that this report be utilized as a co I plete unit. Individual volumes, chapters, pages, etc., which are separated from the main ody of the report will not be complete, and , therefore should not be used in such fashion.

ASBESTOS INSPECTION REPORT

September 8, 2017

FOR

MISSISSIPPI STATE UNIVERSITY

P.O. BOX 5208

MISSISSIPPI STATE, MS 39762

Inspected Buildings Address

USDA Bldg 02 Greenhouse

Mississippi State, MS

PREPARED BY

JOE VENUS, JR

ENVIRONMENTAL SERVICES, LLC

253 DELK ROAD HATTIESBURG, MS 39401

OFFICE 601.582.2277 FAX 601.582.2276

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY 1

1.1 Asbestos Containing Material Summary 1

2.0 PROJECT SUMMARY 2

2.1 Asbestos Survey Protocol 2

2.2 Asbestos Survey Finding 3

2.3 Limitations 3

2.4 Sample Results 4

3.0 DATA SUMMARY 5

3.1 Assessment and Location of Survey Samples 5

3.2 Procedures for Renovation and Demolition 5,6

ENVIRONMENTAL SERVICES, LLC

253 Delk Road, Hattiesburg, MS 39401

1.0 EXECUTIVE SUMMARY

Environmental Services, LLC was retained by David Canterbury of Mississippi State

University Physical Plant, P.O. Box 5208, Mississippi State, MS 39762, to perform a Limited

Asbestos Containing Materials (ACM) inspection. The limited ACM inspection was performed the windows of the USDA Building 02 Greenhouse, on the campus of Mississippi State

University in Starkville MS 39762.

The surveyed was completed on September 8, 2017. Joe Venus, of Environmental Services, LLC did the inspection. The purpose of the survey was to verify the presence, extent, and condition of asbestos containing material (ACM), in the referenced buildings above. The asbestos survey was performed in accordance with applicable local, State and Federal regulations

During the survey, two (02) Homogeneous areas were found, with four (04) samples that were collected from the Site for laboratory analysis. The analytical results indicated that four

(04) samples detected concentrations of asbestos, from the referenced building above. The 3.0

Section entitled Data Summery covers locations of asbestos samples found.

1.1 Asbestos Containing Material Summary

The analytical results of the bulk samples collected during the site survey identified the following materials, with any concentrations of asbestos. Suspect materials with greater than 1% asbestos are considered to be an asbestos containing material by the Environmental Protection agency (EPA). OSHA references worker protection guidelines for exposure to any amounts of asbestos, even below the >1% recognized by the EPA and State Regulators.

Positive Asbestos Containing Materials (ACM), USDA Bldg 02 Greenhouse

Environmental Services, LLC

MSU

Homogeneous Area/Location

Sample Number

Material Sampled, Condition

Asbestos Content

NESHAP

Category

Square/Linera footage

Windows

HA-01

HA-02

01,02

03,04

Exterior glazing

Poor-Friable Interior glazing Poor-Friable

8% Chrysotile

5% Chrysotile

2.0 PROJECT SUMMARY

Joe Venus, a certified asbestos inspector, is accredited through the State of Mississippi

Department of Environmental Quality (MDEQ). He has successfully completed Environmental

Protection Agency approved training in asbestos inspection and removal, and participates in ongoing training offered by accredited associations. His MDEQ Certification Number is

ABI-00001353.

Upon arriving at the Site, Mr. Venus did a short tour of the overall Site. He observed the suspect ACM material to be sampled and assigned a Homogeneous Area (HA) number, description, and measurement to the suspect materials. Homogeneous Areas are defined as suspect materials similar in color, texture, and apparent age of application.

2.1 Asbestos Survey Protocol

The ACM inspection was preformed in accordance with the U.S. Environmental Protection

Agency (USEPA) requirements for implementation of the Asbestos Hazard Emergency

Response Act (AHERA), and the Asbestos School Hazard Reauthorization Act (ASHARA).

The technique used for sampling the suspected materials was designed to minimize possible fiber release and in turn possible contamination of surrounding areas. The MDEQ’s guide to suspect asbestos containing materials include, all building materials, except, unpainted glass, unpainted wood, and unpainted metals. All representative suspect materials sampled were collected in accordance with EPA’s AHERA and “Guidance for Controlling Asbestos

Containing Materials in Buildings” (EPA 560/66-85-024, June 1985).

The sample location is sprayed with amended soapy water mixture when applicable. Then, a core sample of material was collected and properly stored, in a labeled airtight bag. The chain of custody form was completed for a bulk samples collected and subsequently delivered to

Triangle Environmental Services Center, Inc (a certified NVLAP laboratory) for analysis using

Polarized Light Microscopy (PLM). Triangle Environmental Services Center, Inc utilizes the dispersion staining technique according the U. S. EPA method 600/M4-82/020 incorporating visual estimates of identified material percentages. This survey was to identify any of the six major types of asbestos, Chrysotile, Amosite, Crocidolite, Anthophylite, Tremolite, and

Actinolite in the materials sampled.

During the sampling activities, each suspect ACM was touched by the inspector to determine its friability and observed to determine the physical condition of the material. A

Friable Material is a material is defined as a material that can be crumbled, or reduced to a power by hand pressure. Friability of a material directly relates to a potential of the ACM to release airborne fibers. The inspector assessed the suspect ACM, according to its physical condition.

The results of this inspection may not be considered to be a product endorsement by

Environmental Services, LLC, NVLAP, or any agency of the U.S. Government.

Environmental Services, LLC recommends that the identified ACM should be either managed in place with an Operations and Maintenance (O&M) Plan, or abated by a licensed contractor in accordance with all applicable local, State and Federal rules and regulations.

Should additional suspect materials not included in this survey be discovered during maintenance or renovation activities, Environmental Services, LLC recommends that samples of these materials be tested for asbestos content.

2.2 Asbestos Survey Findings

The analytical results of the bulk samples collected during the site survey, September 8, 2017 identified the following materials with concentrations of asbestos. Suspect materials with greater than 1% asbestos are considered to be an asbestos containing material by Mississippi

Department of Environmental Quality (MDEQ) and the Environmental Protection Agency

(EPA). OSHA references worker protection guidelines for exposure to any amounts of asbestos, even below the >1% recognized by the EPA and State Regulators. Table 1 has the positive sample results of all samples collected.

During the survey, two (02) Homogeneous areas were found, with four (04) samples that were collected from the Site for laboratory analysis. The analytical results indicated that four

(04) samples detected concentrations of asbestos, from the referenced building above. The 3.0

Section entitled Data Summery covers locations of asbestos samples found.

2.3 Limitations

This survey was completed in accordance with Federal and State protocols for identifying the presence of asbestos-containing materials. Environmental Services, LLC or the inspector do not warrant that all asbestos containing materials have been located or identified during this inspection. Other areas of suspect ACM may be present in areas not visible or readily accessible to Environmental Services, LLC at the time of the survey. Additionally, prior renovation or repair activities may have altered building materials such that suspect ACM could not be properly identified by the inspector. Should additional suspect ACMs be identified, they should be assumed to contain asbestos and sampled for asbestos content.

The person or persons in charge of the facility should exercise care, any time a suspect material is to be disturbed, which has not been sampled or assumed to contain asbestos.

The liability of Environmental Services, LLC is limited to the amount paid by the client for this report. The client assumes all responsibility for the further distribution of this report and its contents. By making such distribution the client agrees to hold Environmental Services, LLC harmless against all claims of persons so informed of the contents hereof.

If an amount of ACM is listed in this report, it is an approximation based upon field observations and/or limited measurements. A Licensed Asbestos Management Planner prior to development of an O&M Plan should determine the actual quantity of ACM requiring management. Similarly, a Licensed Asbestos Consultant prior to initiation of abatement activities should verify the quantity of ACM requiring abatement.

The inspection date was September 8, 2017. Any changes occurring after this date can alter the data in this inspection report.

2.4 Positive Sample Results

Table 1 Results of samples taken from any location may be considered the same for identical materials in other areas of these buildings.

Mississippi State University 2nd Floor office

Sample # Description Results

01 Ext window glazing HA-01 Contains-asbestos

02 Ext window glazing Contains-asbestos

03 Int window glazing HA-02 Contains-asbestos

04 Int window glazing Contains-asbestos

3.0 DATA SUMMARY

Based on the Asbestos Inspection, Environmental Services, LLC, offers the following; One (1) asbestos-containing materials (ACM) was identified as a result of this investigation and is classified in this category:

Miscellaneous Materials–window glazing materials

3.1 Material, Location and Assessment of Survey Samples

USDA Bldg 02 Greenhouse

The window glazing interior and exterior in Building 02 greenhouse, contains asbestos and is in poor condition

Results of asbestos containing materials, taken from any location of the product may be considered the same for identical materials in other units.

3.2 Procedures for Renovation and Demolition

If renovation to the buildings' interior or exterior should occur and these actions directly affect the physical condition of any or all of the ACM’s, then abatement of these materials should be performed before such activities begin. If abatement (removal, repair, enclosure or encapsulation) actions should occur, the building owner or operator should comply with the following requirements:

a. Asbestos abatement actions should be performed by an accredited and licensed asbestos abatement contractor in a manner prescribed by the

Environmental Protection Agency (EPA) Regulation 40 CFR Parts 61.145, and

61.150 (November 20, 1990), the Mississippi Department of Labor, Occupational Safety and Health Administration (OSHA), Standard 29 CFR

1926.1101.

b. If reportable quantities of ACM’s are abated, the Mississippi Department of

Environmental Quality (MDEQ) should be notified of planned renovation, demolition, or asbestos abatement activities at least 10 working days prior to the scheduled start of these activities, as required by EPA 40 CFR Part

61.145(a) and (b)

3.2 Procedures for Renovation and Demolition, continued

c. All removed asbestos-containing waste material(s) should be transported and deposited at an EPA (MDEQ) approved landfill site, in accordance with EPA 40

CFR Part 61.150 (b)-(e). The disposal site shall be operated in accordance with EPA 40

CFR Part 61.154.

d. The Occupation Safety and Health Administration's (OSHA) Right-to-

Know regulation requires the contractor to advise all workers of the presence of asbestos in the area in which they are working and to inform them of the nature of the hazard involved with exposure to asbestos.

Should any regulated or non regulated ACM be allowed to remain in these buildings, an

Operational and Maintenance (O&M) Plan should be developed so that administration and maintenance personnel can monitor the physical condition of the ACM.

If you should have any questions about this limited asbestos inspection, please contact me at the letterhead address and phone number.

Joe Venus, Jr.