12385_-_Plans_with_Issue_Date.pdf
PDF 12 MB Posted
- Solicitation number
- 0000035700
- Issued by
- Imperial County, California
About this file
These contract drawings, prepared by the California Department of Fish and Wildlife's Facilities Engineering division, detail the Ramer Lake Repairs project located in Imperial County, California. The project involves a comprehensive civil/structural design for lake repairs, with a specific focus on a drop structure, Narcissus drain relocation, and associated infrastructure improvements. The project documents are dated with a contract issue date of May 14, 2025, and include detailed engineering plans for site layout, excavation, embankment, drainage systems, and structural components. The design encompasses multiple sections including outlet structures, drain relocations, and various civil engineering details across Region 6's Inland Deserts area.
The project appears to be funded through the California Department of Fish and Wildlife, with a project number 10311329. The design incorporates complex civil engineering elements such as concrete structures, drainage systems, guardrails, and precise elevation changes, with specific attention to geological and environmental considerations typical of inland desert regions. The drawings indicate extensive earthwork, with cut/fill calculations, over-excavation plans, and detailed structural reinforcement specifications. The project seems to involve significant infrastructure rehabilitation, with precise engineering drawings showing multiple cross-sections, structural details, and site-specific engineering solutions tailored to the unique geographical and environmental conditions of the Imperial County location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12385_-_Bid_Package_Documents.pdf | ||
| 12385_-_Project_Manual_Book_I_of_II.pdf | ||
| 12385_-_Project_Manual_Book_II_of_II.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12/26/2024 3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger Text Box 03/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
-190
-180
-170
-160
-190
-180
-170
-160
8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00
0.30%
VP
I S
TA
4+
.7
EL
-1
.7
0EXISTING GRADE
NARCISSUS DRAIN
CENTERLINE INVERT GRADE
APPROXIMATE
GRADE SHOWN
STA 8+25, EL -178.18
3.
0% 3.
0%
-1
-1
-2
-2
-1
4:
4:
3:
3:
2%
3:
3:
3:
9+00 10+00 11+00
12+00
13+00
14+00 14+54.44
3:
8.3%
3:
7.9%
-170 -170
-172
-171
-175 -177-176
-174
-175 -177-176
-174-175 -174
-175 -176
-174 -173
-172 -171
-168
-169
-170
-171
-167 -172 -171
-170 -169 -168
-172
-173
2%2.
0%
2.
0%
-167-168-169
R =2
'R
=2
PC
0+
.5
PT
1+
.6
PC
2+
.3
PT
3+
.5
14'
L-4
L-5
C-3
C-4
18'
N 1974930.08 E 6786531.15
N 1974832.40 E 6786739.97
STA 9+13.25, 35' L
STA 9+17.72, 53' L
STA 9+85.47, 36' L
STA 10+86.98, 67' L
STA 13+71.23, 62' L
STA 13+31.76, 34' L
STA 13+40.20, 18' L
STA 14+01.94, 55' L
STA 14+32.71, 45' L
STA 10+60.56, 4' L
STA 11+82.63, 4' L
STA 8+44.43, 72' L
STA 8+40, 54' L
DITCH END
STA 14+54.44,
N 1974825.30 E 6786825.05
-170 -170
-170 -170
-175 -175
-175
-175
-170
-165
-165 -165
-165
-165
-167
-170
-170
ALIGNMENT CURVE TABLE
CURVE NO.
C-3
C-4
029°14'35.50"
027°17'37.85"
RADIUS
200.00'
200.00'
TANGENT
52.18'
48.56'
LENGTH
102.08'
95.27'
ALIGNMENT LINE TABLE
LINE NO.
L-4
L-5
LENGTH
94.66
89.87
DIRECTION
S57° 56' 23"E
S85° 14' 01"E
P2299021
Sheet of 26
C21-xx
Drawing Number:Department of Fish and Wildlife
ACCESS COMPLIANCE:
APPROVED:
DESIGNED & DRAWN:
Facilities Engineering
The Natural Resources Agency
State of California
S. K. Murata
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERSAPPROVED
BY
CHIEF ENGINEER DATE
RAMER LAKE REPAIRS
IMPERIAL COUNTY
REGION 6 - INLAND DESERTS
BRYAN PALMA, PE
JANELLE MOYER, PE
PREPARED BY: APPROVED BY:
THE SCOPE OF WORK INVOLVED IN THIS PROJECT IS EXEMPT FROM THE
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS, 2022 CALIFORNIA BUILDING CODE.
W12-2022-001
80'0 40'
SCALE:1"=40'
M
AT
C H
LI
N
E
ST
A 8+
, S
EE
S
H
EE
T N
O
PLAN - STA 8+25 TO STA 13+90
SCALE: 1" = 40'
PROFILE - STA 8+25 TO STA 13+90
HORIZ SCALE: 1" = 40'
VERT SCALE: 1" = 4'
NARCISSUS DRAIN RELOCATION
PLAN AND PROFILE 2
ACCESS ROAD
ACCESS ROAD
LEVEE EMBANKMENT
GRADING SEE SHEET 7
TOP OF SLOPE
KEY NOTES: X
DRAIN FILTER NOT
SHOWN FOR CLARITY
SEE DETAIL 4, SHEET 16
DRAIN BEND PROTECTION
SEE DETAIL 6 ON SHEET 16
1. INSTALL 280' GUARDRAIL PER CALTRANS STANDARD
PLANS, DETAIL A77L1
2. 48" RCP, CLASS III PER TRENCH DETAIL 2 ON SHEET 16
3. VEHICULAR ACCESS RAMP PER DETAIL 8 ON SHEET 16
4. NARCISSUS DRAIN HEADWALL PER DETAIL 7 ON SHEET 16
CUT/FILL EARTHWORK SUMMARY TABLE
FROM STA TO STA CUT (CY) FILL (CY) NET (CY)
8+25 14+40 12,255 132 12,123
12/26/2024 3/25/2025
ISSUE DATE: MAY 14, 2025
AutoCAD SHX Text
NO. 65221
AutoCAD SHX Text
EXP. 09-30-25
AutoCAD SHX Text
NO. 59484
AutoCAD SHX Text
EXP. 12-31-25
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
-170
-160
-190
-180
-170
-160
2.00%
3:1
3:1
4.95%
18'
8'
2.00%
ACCESS
ROAD
4:1
3:1
4:1
8'
-196 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70
Note
FILTERED DRAIN, SEE
DETAIL 4 ON SHEET 16
NARCISSUS DRAIN
CENTERLINE
FINISHED
GRADE, TYP
MATCH EXISTING
GROUND
MITIGATION
BENCH
35'
15' 15'
OVER-EXCAVATION LINE
TOP OF SLOPE
-157.50 L, EL -182.56
TOP OF SLOPE
-183.70 L, EL -179.47±
TOE OF SLOPE
-175.50 L, EL -182.20
TOP OF SLOPE
-108.94 L, EL -178.04
TOE OF SLOPE
-27.36 L, EL -174.00
TOP OF SLOPE
-15.00 L, EL -169.90
TOP OF SLOPE
15.00 R, EL -170.50
TOE OF SLOPE
-144.00 L, EL -187.06
TOE OF SLOPE
-136.00 L, EL -187.06
TOP OF SLOPE
41.80 R, EL -175.20
3:1
LEVEE
EMBANKMENT
CENTERLINE
TOE OF SLOPE
33.80 R, EL -175.20
-190
-180
-170
-160
-190
-180
-170
-160
-210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60
2.00%
3:1 3:1
4.95%
3:1
8'
2.00%
18'
ACCESS
ROAD
4:1
3:1
4:1
8'
FILTERED DRAIN, SEE
DETAIL 4 ON SHEET 16
MATCH EXISTING
GROUND
MITIGATION
BENCH
35' MAX
15' 15'
OVER-EXCAVATION LINE
TOP OF SLOPE
-208.70 L, EL -175.95±
TOP OF SLOPE
-110.26 L, EL -178.10
TOE OF SLOPE
-175.50 L, EL -181.82
TOP OF SLOPE
-157.50 L, EL -182.18
TOP OF SLOPE
-15.00 L, EL -169.90
TOE OF SLOPE
-27.29 L, EL -174.00
TOE OF SLOPE
-144.00 L, EL -186.68
TOE OF SLOPE
-136.00 L, EL -186.68
TOP OF SLOPE
15.00 R, EL -170.50
TOP OF SLOPE
41.80 R, EL -175.20
TOE OF SLOPE
33.80 R, EL -175.20
VEHICULAR
ACCESS
RAMP
3:1
EXISTING
GROUND, TYP
FINISHED
GRADE, TYP
TOP OF SLOPE
-179.10 L, EL -180.55
TOP OF SLOPE
-197.72 L, EL -179.75
-4.31%
18"±
LEVEE
EMBANKMENT
CENTERLINE
NARCISSUS DRAIN
CENTERLINE
P2299021
Sheet of 26
C21-xx
Drawing Number:Department of Fish and Wildlife
ACCESS COMPLIANCE:
APPROVED:
DESIGNED & DRAWN:
Facilities Engineering
The Natural Resources Agency
State of California
S. K. Murata
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERSAPPROVED
BY
CHIEF ENGINEER DATE
RAMER LAKE REPAIRS
IMPERIAL COUNTY
REGION 6 - INLAND DESERTS
BRYAN PALMA, PE
JANELLE MOYER, PE
PREPARED BY: APPROVED BY:
THE SCOPE OF WORK INVOLVED IN THIS PROJECT IS EXEMPT FROM THE
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS, 2022 CALIFORNIA BUILDING CODE.
W12-2022-001
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 3+00
HORZ SCALE: 1" = 10'
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 4+25
HORZ SCALE: 1" = 10'
SCALE: 1"=10'
10 20 30
CROSS-SECTIONS - FINAL GRADING 1
12/26/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
AutoCAD SHX Text
NO. 65221
AutoCAD SHX Text
EXP. 09-30-25
AutoCAD SHX Text
NO. 59484
AutoCAD SHX Text
EXP. 12-31-25
GGeiger
-170
-160
-190
-180
-170
-160
-220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50
2.00% MATCH EXISTING
GROUND
EXISTING
GROUND, TYP
15' 15'
OVER-EXCAVATION LINE
TOP OF SLOPE
-178.54 L, EL -172.68
TOP OF SLOPE
15.00 L, EL -170.50
TOP OF SLOPE
-15.00 L, EL -169.90
STA -1+44, EL -178.55
STA -1+36, EL -178.55
STA -1+22, EL -172.80
STA -1+58, EL -172.80
EL -174.83
EL -174.77
EL -187.33
EL -189.33
STA -1+40, EL -186.33
STA -1+75.50, EL -173.69
STA -0+41.20, EL -174.00
STA -1+02.01, EL -175.68
STA -1+06.71, EL -175.35
STA -0+25.49, EL -173.40
STA 0+33.80, EL -175.20
STA 0+41.80, EL -175.20
DROP
STRUCTURE
SEE SHEET 19
4:13:1
2.76% 3.86%
FINISHED
GRADE, TYP
LEVEE
EMBANKMENT
CENTERLINE
NARCISSUS DRAIN
CENTERLINE
-180
-170
-160
-180
-170
-160
-230 -220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50
3:1 3:1
3.00%
2.00%
±32'
EXIST ACCESS
ROAD
8'
±3'
4.
4:1
2.00%
18'
ACCESS
ROAD
3:1
FILTERED DRAIN, SEE
DETAIL 4 ON SHEET 16
MATCH EXISTING
GROUND
EXISTING
NARCISSUS DRAINFINISHED GRADE, TYP
EXISTING
GROUND, TYP
15' 15'
TOP OF SLOPE
-184.51 L, EL -166.59±
TOP OF SLOPE
-114.49 L, EL -172.86
TOP OF SLOPE
-15.00 L, EL -169.90 TOP OF SLOPE
15.00 R, EL -170.50TOP OF SLOPE
-149.13 L, EL -172.74
TOE OF SLOPE
-167.12 L, EL -172.38
TOE OF SLOPE
-135.63 L, EL -177.24
TOE OF SLOPE
-127.64 L, EL -177.24
35'
GUARDRAIL
SEE NOTE 1, SHEET 9
LEVEE
EMBANKMENT
CENTERLINE
NARCISSUS DRAIN
CENTERLINE
P2299021
Sheet of 26
C21-xx
Drawing Number:Department of Fish and Wildlife
ACCESS COMPLIANCE:
APPROVED:
DESIGNED & DRAWN:
Facilities Engineering
The Natural Resources Agency
State of California
S. K. Murata
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERSAPPROVED
BY
CHIEF ENGINEER DATE
RAMER LAKE REPAIRS
IMPERIAL COUNTY
REGION 6 - INLAND DESERTS
BRYAN PALMA, PE
JANELLE MOYER, PE
PREPARED BY: APPROVED BY:
THE SCOPE OF WORK INVOLVED IN THIS PROJECT IS EXEMPT FROM THE
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS, 2022 CALIFORNIA BUILDING CODE.
W12-2022-001
SCALE: 1"=10'
10 20 30
NARCISSUS DRAIN STA 5+50
HORZ SCALE: 1" = 10'
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 11+40
HORZ SCALE: 1" = 10'
VERT SCALE: 1" = 5'
CROSS-SECTIONS - FINAL GRADING 2
KEY NOTES:
1. SURVEY UNABLE TO CAPTURE BOTTOM OF THE DRAIN,
CONTRACTOR TO NOTIFY ENGINEER IF THE BOTTOM OF
THE DRAIN IS LOWER THAN THE SHOWN EXCAVATION
LIMIT.
12/26/2024 3/25/2025
ISSUE DATE: MAY 14, 2025
AutoCAD SHX Text
NO. 65221
AutoCAD SHX Text
EXP. 09-30-25
AutoCAD SHX Text
NO. 59484
AutoCAD SHX Text
EXP. 12-31-25
GGeiger
-170
-160
-180
-170
-160
-160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50
3:13:1
2.00%
8'
4.
5'
4:1
EXIST ACCESS
ROAD
±13'
2.00%
18'
VEHICULAR
ACCESS
RAMP
3:1
FILTERED DRAIN, SEE
DETAIL 4 ON SHEET 16
MATCH EXISTING
GROUND
EXISTING
GROUND, TYP
FINISHED GRADE,
TYP EXISTING
NARCISSUS
DRAIN
15' 15'
TOP OF SLOPE
15.00 R, EL -170.50
TOP OF SLOPE
-15.00 L, EL -169.90TOP OF SLOPE
-96.41 L, EL -165.66±
TOP OF SLOPE
-68.94 L, EL -170.40
TOE OF SLOPE
-87.42 L, EL -169.33
TOE OF SLOPE
-46.75 L, EL -176.54
TOE OF SLOPE
-38.71 L, EL -176.54
TOP OF SLOPE
-60.27 L, EL -172.04
TOP OF SLOPE
-25.21 L, EL -172.04
TOP OF SLOPE
-60.94 L, EL -172.00
TOP OF SLOPE
-24.16 L, EL -172.00
LEVEE
EMBANKMENT
CENTERLINE
NARCISSUS DRAIN
CENTERLINE
-190
-180
-170
-190
-180
-170
-180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
8'
3:1
2.00% 3:1
EXISTING
GROUND,
TYP
FINISHED
GRADE, TYP
3:1
18'
FILTERED DRAIN, SEE
DETAIL 4 ON SHEET 16
15' 15'
2.00%
OVER-EXCAVATION LINE
3:1 MATCH EXISTING
GROUND
EXISTING GROUND, TYP.
TOE OF SLOPE
-169.62 R, EL -178.60
TOE OF SLOPE
-157.20 R, EL -182.74
TOE OF SLOPE
-125.70 R, EL -187.60
TOE OF SLOPE
-117.70 R, EL -187.60
TOE OF SLOPE
-85.23 R, EL -176.77
TOE OF SLOPE
-27.29 R, EL -174.00
TOP OF SLOPE
-15.00 R, EL -169.90 TOP OF SLOPE
15.00 R, EL -170.50
TOE OF SLOPE
-139.20 R, EL -183.10
2.00%
ACCESS
ROAD
4.34%
4.90%
NARCISSUS DRAIN
CENTERLINE
LEVEE
EMBANKMENT
CENTERLINE
-190
-180
-170
-190
-180
-170
-230 -220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70
PROPOSED
GROUND, TYP
STA -1+40, EL -186.37
EXISTING
GROUND, TYP
15' 15'
STA -1+80.93, EL -174.34
STA -1+07.08, EL -175.97
TOP OF SLOPE
15.00 R, EL -170.50
TOP OF SLOPE
-15.00 R, EL -169.90
TOE OF SLOPE
-27.30 R, EL -174.00
OVER-EXCAVATION LINE
MATCH EXISTING
GROUND
3:1
2.00%
4:1 8'
TOE OF SLOPE
33.80 R, EL -175.20
TOE OF SLOPE
41.80 R, EL -175.20
MATCH EXISTING GROUND
2.47%
LEVEE
EMBANKMENT
CENTERLINE
P2299021
Sheet of 26
C21-xx
Drawing Number:Department of Fish and Wildlife
ACCESS COMPLIANCE:
APPROVED:
DESIGNED & DRAWN:
Facilities Engineering
The Natural Resources Agency
State of California
S. K. Murata
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERSAPPROVED
BY
CHIEF ENGINEER DATE
RAMER LAKE REPAIRS
IMPERIAL COUNTY
REGION 6 - INLAND DESERTS
BRYAN PALMA, PE
JANELLE MOYER, PE
PREPARED BY: APPROVED BY:
THE SCOPE OF WORK INVOLVED IN THIS PROJECT IS EXEMPT FROM THE
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS, 2022 CALIFORNIA BUILDING CODE.
W12-2022-001
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 12+00
HORZ SCALE: 1" = 10'
SCALE: 1"=10'
10 20 30
CROSS-SECTIONS - FINAL GRADING 3
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 1+50
HORZ SCALE: 1" = 10'
VERT SCALE: 1" = 5'
NARCISSUS DRAIN STA 5+25
HORZ SCALE: 1" = 10'
KEY NOTES:
1. SURVEY UNABLE TO CAPTURE BOTTOM OF THE DRAIN,
CONTRACTOR TO NOTIFY ENGINEER IF THE BOTTOM OF
THE DRAIN IS LOWER THAN THE SHOWN EXCAVATION
LIMIT.
12/26/2024 3/25/2025
ISSUE DATE: MAY 14, 2025
AutoCAD SHX Text
NO. 65221
AutoCAD SHX Text
EXP. 09-30-25
AutoCAD SHX Text
NO. 59484
AutoCAD SHX Text
EXP. 12-31-25
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
ISSUE DATE: MAY 14, 2025
GGeiger
Department of Fish and Wildlife
ACCESS COMPLIANCE:
APPROVED:
DESIGNED & DRAWN:
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
BY
CHIEF ENGINEER DATE
PREPARED BY: APPROVED BY:
THE SCOPE OF WORK INVOLVED IN THIS PROJECT IS EXEMPT FROM THE
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
ACCESSIBILITY REQUIREMENTS IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS, 2022 CALIFORNIA BUILDING CODE.
W12-2022-001
GENERAL NOTES:
1. DIMENSIONS, ELEVATIONS, AND DETAILS OF EXISTING CONSTRUCTION
ARE BASED ON HISTORICAL DRAWINGS AND FIELD MEASUREMENTS. THE
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONAL AND DETAIL
INFORMATION FOR EXISTING STRUCTURES SHOWN ON THE DRAWINGS
PRIOR TO DETAILING, FABRICATION, AND CONSTRUCTION. ANY
DEVIATIONS FROM WHAT IS NOTED ON THE DRAWINGS SHALL BE
REPORTED IN WRITING TO THE ENGINEER.
2. SHOP DRAWINGS SHALL BE PREPARED BASED ON INFORMATION FIELD
VERIFIED BY THE CONTRACTOR AND DRAWINGS RELEASED FOR
CONSTRUCTION BY THE ENGINEER. SHOP DRAWINGS PREPARED USING
UNVERIFIED INFORMATION AND/OR DRAWINGS NOT RELEASED FOR
CONSTRUCTION MAY BE RETURNED WITHOUT REVIEW.
3. IN THE CASE OF CONFLICTS BETWEEN THE SPECIFICATIONS, THE
DRAWINGS, AND/OR VENDOR DRAWINGS, THE ENGINEER SHALL BE
NOTIFIED IN WRITING TO RESOLVE THE DISCREPANCY PRIOR TO
PROCEEDING WITH DETAILING, FABRICATION, OR CONSTRUCTION.
4. IF DEVIATIONS TO THE “APPROVED FOR CONSTRUCTION” DESIGN
DRAWINGS AND/OR “RELEASED FOR PRODUCTION” FABRICATION
DRAWINGS ARE NECESSARY DUE TO INTERFERENCES, FABRICATION
ERRORS, DISCOVERED CONDITIONS, OR OTHER CAUSES, THE ENGINEER
SHALL BE NOTIFIED IN WRITING. THE CONTRACTOR SHALL SUBMIT
PROPOSED CHANGES TO THE ENGINEER FOR REVIEW PRIOR TO MAKING
CHANGES. CHANGES MADE WITHOUT ENGINEER CONCURRENCE SHALL
BE SUBJECT TO REWORK AT NO COST TO THE OWNER.
5. THE CONTRACTOR SHALL CONDUCT THEIR OPERATIONS IN SUCH A
MANNER AS NOT TO INTERFERE WITH ACCESS TO OR OPERATIONS OF
OTHER PROJECT FACILITIES.
CONCRETE NOTES:
1. ALL CONCRETE WORK, INCLUDING BATCHING, MIXING, TRANSPORTING,
PLACING, FINISHING, CURING, AND REPAIR SHALL CONFORM TO THE
REQUIREMENTS OF THE PROJECT SPECIFICATIONS AND TO THE
FOLLOWING REQUIREMENTS:
2. 4" SLUMP BEFORE ADDITION OF SUPER PLASTICIZER TO 8" MAXIMUM WITH
ADDITION OF SUPER PLASTICIZER
3. CONCRETE MIX PROPORTIONS SHALL BE DEVELOPED IN ACCORDANCE
WITH ACI 301 AND SHALL BE SUBMITTED TO THE ENGINEER AND APPROVED
PRIOR TO ANY PLACEMENT.
4. PORTLAND CEMENT FOR CONCRETE SHALL BE TYPE II CONFORMING TO
ASTM C150 UNLESS OTHERWISE APPROVED BY THE ENGINEER.
5. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60 AND SHALL HAVE A
MINIMUM OF 3 INCH CLEAR. COVER UNLESS OTHERWISE NOTED. ALL
REINFORCING FABRICATION SHALL CONFORM TO THE CRSI “MANUAL OF
STANDARD PRACTICE” AND ACI 315. (DETAILING MANUAL.)
6. CONCRETE FINISHING REQUIREMENTS AND FINISH OF FORMED SURFACES:
a. THE CLASSES OF FINISH FOR FORMED CONCRETE SURFACES ARE
DESIGNATED BY USE OF SYMBOLS F1 AND F2.
b. NO SACK RUBBING OR SANDBLASTING EXCEPT AT VERTICAL
CONSTRUCTION JOINTS WILL BE REQUIRED ON FORMED SURFACES.
c. NO GRINDING OR RUBBING WILL BE REQUIRED ON FORMED SURFACES
OTHER THAN THAT NECESSARY FOR REPAIR OF SURFACE
IMPERFECTIONS.
d. THE CLASSES OF FINISH SHALL APPLY AS FOLLOWS:
F1. FINISH F1 APPLIES TO FORMED SURFACES UPON OR AGAINST
WHICH BACKFILL OR CONCRETE IS TO BE PLACED. THESE SURFACES
REQUIRE NO TREATMENT AFTER FORM REMOVAL EXCEPT REMOVAL
AND REPAIR OF DEFECTIVE CONCRETE AND THE SPECIFIED CURING.
CORRECTION OF SURFACE IRREGULARITIES WILL BE REQUIRED FOR
DEPRESSIONS ONLY AND ONLY FOR THOSE THAT EXCEED ONE INCH.
F2. FINISH F2 APPLIES TO ALL FORMED SURFACES NOT PERMANENTLY
CONCEALED BY BACKFILL OR CONCRETE, OR NOT REQUIRED TO
RECEIVE FINISHES AND SHALL INCLUDE FORMED SURFACES FOR
WHICH F2 FINISH IS SPECIFIED ON THE DRAWINGS. SURFACES FOR
WHICH FINISH F2 IS SPECIFIED WILL NEED NO FILLING OF PITS OR SACK
RUBBING AND NO GRINDING OTHER THAN THAT NEEDED FOR REPAIR
OF SURFACE IMPERFECTIONS. SURFACE IRREGULARITIES SHALL NOT
EXCEED ONE-FOURTH OF AN INCH FOR ABRUPT IRREGULARITIES AND
ONE-HALF OF AN INCH FOR GRADUAL IRREGULARITIES.
7. CONTRACTOR SHALL ROUGHEN EXISTING CONCRETE SURFACE TO A
MINIMUM 1/4" AMPLITUDE PRIOR TO PLACING ADJACENT CONCRETE.
8. CHAMFER ALL EXPOSED CORNERS 3/4 INCH.
9. CONCRETE TO BE NORMAL WEIGHT READY MIXED CONCRETE CONFORMING
TO ASTM C94. READY MIXED CONCRETE BATCH PLANT TO BE CERTIFIED BY
NRMCA.
10. CONCRETE MIX DESIGN SUBMITTAL TO INCLUDE: SIEVE ANALYSIS AND
SOURCE OF FINE AND COURSE AGGREGATES, TEST FOR AGGREGATE
ORGANIC IMPURITIES, TEST FOR DELETERIOUS AGGREGATE PER ASTM
C1293, PROPORTIONING OF ALL MATERIALS, MILL CERTIFICATE FOR
CEMENT, TYPE OF FLY ASH WITH CERTIFICATE OF CONFORMANCE TO
REQUIREMENTS, SLUMP, AIR CONTENT, AND 28-DAY CYLINDER
COMPRESSIVE TEST RESULTS OF TRIAL MIXES AS INDICATED BELOW. FOR
PROPOSED ADMIXTURES SUBMIT BRAND, TYPE, ASTM DESIGNATION, AND
QUANTITY OF EACH ADMIXTURE PROPOSED FOR USE. CONCRETE MIX
DESIGN SHALL BE STAMPED BY A LICENSED CALIFORNIA CIVIL ENGINEER.
11. SUBMIT REINFORCING STEEL SHOP DRAWINGS THAT SHOW GRADE, SIZE,
NUMBER, CONFIGURATION, SPACING, LOCATION, AND ALL FABRICATION
AND PLACEMENT DETAILS. SHOP DRAWINGS TO HAVE SUFFICIENT DETAIL
TO PERMIT INSTALLATION OF REINFORCING WITHOUT HAVING TO MAKE
REFERENCE TO CONTRACT DRAWINGS. OBTAIN APPROVAL OF SHOP
DRAWINGS BY ENGINEER BEFORE FABRICATION.
12. SUBMIT STRENGTH TEST RESULTS OF IN PLACE CONCRETE INCLUDING
SLUMP, AIR CONTENT, AND CONCRETE TEMPERATURE. TESTING
FREQUENCY IS ONCE PER 100 CUBIC YARD OR EACH DAY OF POUR,
WHICHEVER IS MORE FREQUENT, AS PROVIDED IN CA DOT SPEC SECTION
90-1.01D(10)(B)(IV) QUALITY CONTROL TESTING FREQUENCIES.
13. PREPARE A DELIVERY TICKET FOR EACH LOAD FOR READY-MIXED
CONCRETE. THE TICKET IS TO SHOW MIX IDENTIFICATION MARK, QUANTITY
DELIVERED, AMOUNT OF EACH MATERIAL IN BATCH, OUTDOOR TEMP IN THE
SHADE, TIME AT WHICH CEMENT WAS ADDED, NUMERICAL SEQUENCE OF
THE DELIVERY, AMOUNT OF WATER ADDED.
14. MIX WATER TO BE POTABLE, CLEAN, FREE OF OILS, ACIDS, AND ORGANIC
MATTER.
15. AGGREGATES TO BE PER ASTM C33, EXCEPT AS MODIFIED BY THE
FOLLOWING. FINE AGGREGATES TO BE CLEAN NATURAL SAND. NO
MANUFACTURED OR ARTIFICIAL SAND.COARSE AGGREGATE TO BE
CRUSHED ROCK, NATURAL GRAVEL, OR OTHER INERT GRANULAR
MATERIAL. MAXIMUM AMOUNT OF CLAY OR SHALE PARTICLES: 1%.
16. AIR CONTENT IS TO BE MEASURED IN ACCORDANCE WITH ASTM C231, ASTM
C173, OR ASTM C138.
17. SLUMP TO BE DETERMINED PER ASTM C143 AND MEASURED AT POINT OF
DISCHARGE OF THE CONCRETE INTO THE CONCRETE CONSTRUCTION
SLUMP MAY BE ADJUSTED IN THE FIELD THROUGH THE USE OF WATER
REDUCERS. COORDINATE DOSAGE AND MIXING REQUIREMENTS WITH
CONCRETE SUPPLIER.
18. CONTRACTOR IS RESPONSIBLE FOR DESIGN AND ERECTION OF
FORMWORK. FORMWORK IS TO BE CONSTRUCTED SO THAT CONCRETE
MEMBERS AND STRUCTURES ARE OF CORRECT SIZE, SHAPE, ALIGNMENT,
ELEVATION, AND POSITION. ALLOWABLE TOLERANCES TO BE PER THE
REQUIREMENTS OF ACI 347.
19. CLEAN AND ADJUST FORMS PRIOR TO CONCRETE PLACEMENT.
20. POSITION, SUPPORT, AND SECURE REINFORCEMENT AGAINST
DISPLACEMENT. LOCATE AND SUPPORT REINFORCEMENT WITH CHAIRS,
RUNNERS, BOLSTERS, SPACERS, AND HANGERS, AS REQUIRED. SET AND
BUILD IN ANCHORAGE DEVICES AND OTHER EMBEDDED ITEMS REQUIRED
FOR OTHER WORK THAT IS ATTACHED TO, OR SUPPORTED BY CONCRETE.
21. DO NOT WELD REINFORCING BARS.
22. PLACE CONCRETE IN COMPLIANCE WITH ACI 304R AND ACI 304.2R. PLACE IN
A CONTINUOUS OPERATION WITHIN PLANNED JOINTS, SECTIONS, OR
MEMBERS, AND IN SUCH A WAY THAT PREVENTS AGGREGATE
SEGREGATION. DO NOT ALLOW CONCRETE TO FALL MORE THAN 4 FEET.
23. CONSOLIDATE ALL CONCRETE USING MECHANICAL VIBRATORS
SUPPLEMENTED WITH HAND RODDING AND TAMPING, SO THAT CONCRETE
IS WORKED AROUND REINFORCEMENT AND EMBEDDED ITEMS INTO ALL
PARTS OF FORMS.
24. PROTECT CONCRETE FROM PHYSICAL DAMAGE OR REDUCED STRENGTH
DUE TO WEATHER EXTREMES. IN COLD WEATHER APPLY ACI 306.1 EXCEPT
AS MODIFIED HEREIN. DO NOT PLACE CONCRETE ON FROZEN GROUND OR
IN CONTACT WITH FORMS OR REINFORCING BARS COATED WITH FROST,
ICE, OR SNOW. DO NOT PLACE HEATED CONCRETE THAT IS WARMER THAN
80 DEGREES F (FAHRENHEIT) IF FREEZING TEMPERATURES ARE EXPECTED
DURING CURING, MAINTAIN THE CONCRETE TEMPERATURE AT OR ABOVE 50
DEGREES F FOR SEVEN DAYS OR 70 DEGREES F FOR 3 DAYS. DO NOT
ALLOW CONCRETE TO COOL SUDDENLY.
25. IN HOT WEATHER APPLY ACI 305.1 EXCEPT AS MODIFIED HEREIN. AT AIR
TEMPERATURES OF 90 DEGREES F AND ABOVE, KEEP CONCRETE AS COOL
AS POSSIBLE DURING PLACEMENT AND CURING. DO NOT ALLOW CONCRETE
TEMPERATURE TO EXCEED 90 DEGREES AT PLACEMENT. DO NOT PLACE
CONCRETE WHEN THE ACTUAL OR ANTICIPATED EVAPORATION RATE
EQUALS OR EXCEEDS 0.2 POUNDS/SF/HR AS DETERMINED FROM ACI 305.1,
FIGURE 2.1.5.
26. BEGIN CURING CONCRETE AS SOON AS FREE WATER HAS DISAPPEARED
FROM EXPOSED SURFACES, CURE CONCRETE BY USE OF MOISTURE
RETAINING COVER, BURLAP KEPT CONTINUOUSLY WET OR BY MEMBRANE
CURING COMPOUND. PROVIDE CURING FOR MINIMUM OF 14 DAYS.
27. LEAVE FORMS AND SHORING USED TO SUPPORT CONCRETE UNTIL IT HAS
REACHED ITS SPECIFIED 28-DAY COMPRESSIVE STRENGTH.
28. QA TESTING TO BE PERFORMED BY AN INDEPENDENT TESTING AGENCY. QA
TESTING TO CONSIST OF SLUMP, AIR CONTENT, TEMPERATURE, AND
COMPRESSIVE STRENGTH CYLINDERS PER ASTM C31, ASTM C39, ASTM
C143, ASTM C172, ASTM C231, AND ASTM C1064. MAKE 4 CYLINDERS FOR
EACH CONCRETE PLACEMENT. TEST 1 CYLINDER @ 7 DAYS, 2 @ 28 DAYS,
AND HOLD 1 IN RESERVE.
GROUT NOTES:
1. GROUT SHALL BE FIVE-STAR HIGH PERFORMANCE NON-SHRINK GROUT
WITH MINIMUM COMPRESSIVE STRENGTH AT THE END OF 28 DAYS OF 5,000
PSI MINIMUM WITH WATER CONSISTENT WITH PLACING REQUIREMENTS.
NON-SHRINK GROUT SHALL MEET THE PERFORMANCE REQUIREMENT OF
ASTM C1107.
2. WATER: WATER FOR MIXING OF GROUT SHALL BE CLEAN AND FREE OF OIL,
ACIDS, ORGANIC MATERIALS, ALKALIES AND OTHER SALTS. WATER SHALL
HAVE A PH OF 7.0 TO 9.0.
3. MIX GROUT IN PROPORTIONS AND ACCORDING TO THE PROCEDURES
RECOMMENDED BY THE MANUFACTURER FOR A FLOWABLE GROUT MIX
UNLESS OTHERWISE SPECIFIED.
4. THE AMBIENT TEMPERATURE OF GROUT AND SUBSTRATE MATERIALS
SHALL BE WITHIN THE RANGE REQUIRED PER THE GROUT
MANUFACTURER'S RECOMMENDATIONS.
5. ALL SURFACES SHALL BE CLEANED TO REMOVE ANY FOREIGN MATTER
LIKELY TO AFFECT THE BOND OR PERFORMANCE OF GROUT.
6. PRIOR TO PLACING GROUT, ALL SURFACES SHALL BE SATURATED WITH
CLEAN WATER PER THE GROUT MANUFACTURER'S RECOMMENDATIONS.
7. STORE, HANDLE AND PLACE IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE AMERICAN CONCRETE INSTITUTE FOR
CEMENT AND CEMENT PRODUCTS, AND MANUFACTURER'S
RECOMMENDATIONS.
8. DO NOT STORE PACKAGES OF GROUT IN CONTACT WITH THE GROUND FOR
ANY EXTENDED LENGTH OF TIME AND KEEP AWAY FROM ALL MOIST AND
HIGH HUMIDITY AREA.
POST-INSTALLED ANCHOR AND DOWEL NOTES:
1. POST-INSTALLED THREADED ANCHORS SHALL BE SS HILTI KWIK BOLT TZ2
ANCHORS (ICC-ES EVALUATION REPORT NO. ESR-4266) AND THE
INSTALLATION SHALL COMPLY WITH THE MPII REGARDING THE DRILLING
METHODS, HOLE DIAMETERS, AND CLEANING REQUIREMENTS, ANCHOR
INSTALLATION AND ANY OTHER REQUIREMENTS FOR THE DIAMETER AND
LENGTH OF ANCHOR EMBEDMENT SPECIFIED ON THE DRAWINGS.
2. ALL FIELD PERSONNEL INVOLVED WITH DRILLING, CLEANING, AND
INSTALLATION OF ANCHORS SHALL BE TRAINED BY THE MANUFACTURER'S
REPRESENTATIVE, OR AN EQUIVALENT PROGRAM ACCEPTABLE TO THE
OWNER.
3. IF UNSOUND CONCRETE, AS DETERMINED BY THE OWNER, IS
ENCOUNTERED PRIOR TO OR DURING ANCHOR OR DOWEL INSTALLATION,
NOTIFY THE ENGINEER IMMEDIATELY.
4. INSPECTION REQUIREMENTS FOR POST-INSTALLED ANCHORS ARE
PROVIDED IN CA DOT SPEC SECTION 75-3.02C ANCHOR DEVICES.
F'c (PSI) AGE (DAYS)
284000
SLUMP
(IN)
MAX COARSE
AGGREGATE
SIZE (IN)
1-1/2 6±1
AIRMIN STRENGTH
TYPE
SEE NOTE 2NORMAL
MAX WATER
0.45
STRUCTURAL STEEL NOTES:
1. ALL STRUCTURAL STEEL WORK IS TO BE IN ACCORDANCE WITH THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) CODE OF STANDARD
PRACTICE FOR BUILDINGS AND BRIDGES, AS WELL AS THESE DRAWINGS, AND
THE PROJECT SPECIFICATIONS.
2. MATERIALS
ROLLED WIDE FLANGE SHAPES: ASTM A992
OTHER ROLLED SHAPES, PLATES, AND BARS ASTM A36
ROUND AND SQUARE HSS: ASTM A500 GR. B
STRUCTURAL STEEL PIPE: ASTM A53 GR. B
HIGH STRENGTH BOLTS: ASTM A325, GALVANIZED
THREADED ANCHOR RODS: ASTM F1554 GR. 36, GALVANIZED
STAINLESS STEEL PLATE: ASTM A240, TYPE 304
WELD ELECTRODE E70XX
3. ALL CARBON STEEL IS TO BE GALVANIZED IN ACCORDANCE WITH ASTM A123.
4. ALL WELDING OF CARBON STEEL SHALL BE IN ACCORDANCE WITH AMERICAN
WELDING SOCIETY (AWS) D1.1 (LATEST EDITION). ALL WELDING OF STAINLESS
STEEL SHALL BE IN ACCORDANCE WITH AWS D1.6 (LATEST EDITION).
TIMBER NOTES:
1. TIMBER STOPLOGS SHALL BE FABRICATED FROM NO. 2 PRESSURE TREATED
SOUTHERN PINE. MATERIAL SHALL BE TREATED TO THE REQUIREMENTS FOR
A GROUND CONTACT/FRESH WATER, GENERAL USE SERVICE CONDITION
(UC4A) IN ACCORDANCE WITH AWPA STANDARDS U1 OR ICC-ES EVALUATION
REPORTS.
STRUCTURAL ABBREVIATIONS:
ACI - AMERICAN CONCRETE INSTITUTE
AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM - AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS - AMERICAN WELDING SOCIETY/ AMERICAN WOOD COUNCIL
AWPA - AMERICAN WOOD PROTECTION AGENCY
BOF - BOTTOM OF FOOTING
CA DOT - CALIFORNIA DEPARTMENT OF TRANSPORTATION
CBS - CALIFORNIA BUILDING CODE
CJ - CONSTRUCTION JOINT
CLR - CLEAR
GIR - GEOTECHNICAL INVESTIGATION REPORT
ICC-ES - INTERNATIONAL CODE COUNCIL - EVALUATION SERVICE
PSI - POUNDS PER SQUARE INCH
IN - INCH
SF - SQUARE FOOT
HR - HOUR
SC - SCHEDUEL
SS - STAINLESS STEEL
TOC - TOP OF CONCRETE
TOF - TOP OF FOOTING
STRUCTURAL NOTES
DESIGN CRITERIA NOTES:
1. DESIGN REFERENCES:
· AMERICAN CONCRETE INSTITUTE (ACI). ACI 318-19. BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE. 2019.
· AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE). ASCE 7-22. MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. 2022.
· AMERICAN WOOD COUNCIL (AWS). NATIONAL DESIGN SPECIFICATION FOR
WOOD CONSTRUCTION. 2018.
· CALIFORNIA BUILDING STANDARDS COMMISSION (CBSC). 2022 CALIFORNIA
BUILDING CODE (CBC). 2022.
2. ALLOWABLE BEARING PRESSURES FOR FOUNDATION DESIGN PROVIDED
PER THE GEOTECHNICAL INVESTIGATION REPORT (GIR) PREPARED BY HDR
DATED MAY 19, 2023:
· 1,600 PSF FOR DEAD LOADS (BASED ON FACTOR OF SAFETY OF 3.0)
· 1,920 PSF FOR DEAD LOADS PLUS LIVE LOADS (BASED ON FACTOR OF
SAFETY OF 2.5)
· 2,400 PSF FOR TOTAL LOADS INCLUDING WIND AND SEISMIC (BASED ON
FACTOR OF SAFETY OF 2.0)
3. BUOYANT UPLIFT:
PER THE GIR, AN AVERAGE SERVICE UPLIFT PRESSURE OF 500 PSF WILL BE
CONSIDERED, AND A TOTAL SOIL UNIT WEIGHT OF 120 PCF WILL BE USED IN
EVALUATING UPLIFT RESISTANCE.
4. SEISMIC LOADING:
THE SEISMIC PARAMETERS TO BE USED FOR THE DESIGN WERE PROVIDED
IN THE GIR AND ARE SUMMARIZED IN TABLE 1.
1. IN ACCORDANCE WITH EXCEPTION NO. 3 IN ASCE 7-16, SECTION 11.4.8
(SITE-SPECIFIC GROUND MOTION PROCEDURES), THE SEISMIC DESIGN
PARAMETERS IN THIS TABLE CAN ONLY BE USED WHEN THE FUNDAMENTAL
STRUCTURE PERIOD (T) IS LESS THAN OR EQUAL TO TS AND THE
EQUIVALENT STATIC FORCE PROCEDURE IS USED. IF THESE CRITERIA ARE
NOT MET, THEN SITE-SPECIFIC GROUND MOTION PROCEDURES SHALL BE
PERFORMED.
2. THE SITE IS LOCATED AT: LATITUDE: 33.0836 DEGREES, LONGITUDE:
-115.51734 DEGREES.
3. THE MCER IS THE RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE.
4. THE MCEG IS THE GEOMETRIC MEAN MAXIMUM CONSIDERED EARTHQUAKE.
PARAMETER/COEFFICIENT DESCRIPTION PARAMETER/COEFFICIENT VALUE
MAPPED MCE SPECTRAL
RESPONSE ACCELERATION
PARAMETER AT SHORT PERIODS
R Ss 1.50g
MAPPED MCE SPECTRAL RESPONSE
ACCELERATION PARAMETER AT
PERIOD OF 1 SECOND
R S1 0.60g
SITE CLASSIFICATION
(BASED ON SOIL CONDITIONS)
SITE CLASS E
SHORT-PERIOD SITE
AMPLIFICATION COEFFICIENT
F a 1.2
LONG-PERIOD SITE
AMPLIFICATION COEFFICIENT
F v 1.2
SMS 1.80g
TABLE 1. ASCE 7-16/2022 CBC SEISMIC DESIGN PARAMETERS
MCE SPECTRAL DESIGN
PARAMETERS ADJUSTED
FOR SITE CLASS
R
[3]
SM1 1.20g
DESIGN SPECTRAL
ACCELERATION PARAMETERS
SDS
SD1 0.80g
1.20g
SEISMIC DESIGN CATEGORY FOR RISK
CATEGORY III
D
PERIOD DEFINED BY THE
RATIO S / S
0.67s
D1 DS
TS
LONG-PERIOD TRANSITION 8sTL
MCE PEAK GROUND ACCELERATION
ADJUSTED FOR SITE CLASS
PGA M 0.60gG [4]
MCE , 5% DAMPED SPECTRAL
RESPONSE ACCELERATOIN PARAMETER
AT SHORT PERIOD ADJUSTED FOR SITE
CLASS
R
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
4'-0" 4'-0"
TYP1'-6"
GUARDRAIL, TYP
4'-0"
CUTOFF WALL 9
2'-0"
CULVERT HEADWALL
4'-0" 2'-0"
18'-0" 18'-0"
S T
A
.5
4'-0"
CLNARCISSUS
DRAIN
PLAN AT TOC EL -172.8
DROP STRUCTURE CONCRETE OUTLINE
SCALE: 3/8"=1'-0"
C
4'-0"
SLOPE
F A
C E
F L
A S
H B
O A
R D
W E
IR
TIMBER FLASHBOARD WEIR
EL -176.05
STILLING
BASIN
B
A
E
D
F
WALKWAY TOC
EL -172.8
SLOPE
DRAIN INVERT
WALKWAY
DRAIN SIDE SLOPE
SEE TYPICAL DRAIN SECTION
SHEET 16
CL CULVERT
1'-0"
TYP
FLOW
ROAD CROSSING
SEE SHEET 6
NARCISSUS DRAIN
TOP OF SLOPE
3:13:1
A C
C E
S S
R O
A D
S E
E S
H E
E T
SLOPE
SLOPE
SLOPE
SLOPE
NARCISSUS DRAIN
TOP OF SLOPE
135°2
48" RCP
WALKWAY DETAIL
SCALE: 3/4"=1'-0"
WALKWAY TOC
EL -172.8
CL NARCISSUS
DRAIN
8'-0"10" 10"
H
1/2"
TYP
G
/2
T Y
P
C L R
T Y
P
T Y
P T
Y P
T Y
P approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - PLAN
POST TO CONCRETE
GUARDRAIL
GUARDRAIL RETURN
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES
SEE SHEET 18.
LEGEND:
22 0 4
SCALE: 3/8"=1'-0"
11 0 2
SCALE: 3/4"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
N
18'-0" 18'-0"
2'-0" 2'-0"4'-0"4'-0"
C L R
#8@8" EF
TYP
CUT VERTICAL & HORIZONTAL
REINFORCEMENT AT PIPE PENETRATION.
HORIZONTAL REINFORCEMENT SIMILAR
NOT SHOWN FOR CLARITY
E F
#8@8" T&B
#8@8" T&B
A
SECTION
SCALE: 1/2"=1'-0"
CL
DROP STRUCTURE
TOC
EL -172.8
CONSTRUCTION JOINT
EL -178.55
#5@8"
TIE TO #8 VERT, TYP
INV EL -186.33
4' -0
" D
IA
TOF
EL -187.33
BOF
EL -189.33
EL -191.33
OVER EXCAVATE TO EL -191.33 AND REPLACE
WITH 24" LAYER OF ENGINEERED FILL, SEE NOTE 3
ADD (2) #5 BARS
DIAGONALLY, EF EW,
AS SHOWN
STRUCTURAL
BACKFILL
ADD (2) BARS EACH SIDE EACH FACE
#8 VERTICAL
#6 HORIZONTAL
E F
3"
C L R
3" CLR 4" CLR 3" CLR4" CLR
3"
STRUCTURAL
BACKFILL
APPROXIMATE ROAD CROSSING
GRADING BACKFILL PROFILE AGAINST
WEST SIDE OF WALL (BEYOND)FINISH F1
FINISH F1
ACCESS ROAD
FINISHED GRADE
EL -175.1FINISHED GRADE
EL -175.22
FINISHED GRADE
FINISHED GRADE
GUARDRAIL (BEYOND)
VERTICAL REINFORCEMENT IN
CULVERT HEADWALL WALL (BEYOND)
#8@8" EF
TYP
WATERSTOP TYP
HYDROPHILIC WATERSTOP
ALL AROUND
L A
P S
P L
IC
E T
Y P
S E
E N
O T
E
3" C
LR
GUARDRAIL
1/3
FOR REINFORCING
AND COVER SEE
PLAN AND SECTION
1/31/3
3/4" CHAMFER
TYP
WALL CONSTRUCTION JOINT DETAIL
SCALE: 1 1/2"=1'-0"
CJ
CLR CLR
WATERSTOP TYP
1/31/31/3
WALL TO WALL CONSTRUCTION JOINT SECTION
SCALE: 1 1/2"=1'-0"
N
C L R
C L R
CLR
#8@8
#6@8
FOR REINFORCING
AND COVER SEE
PLAN AND SECTION
CLR
F O
R R
E
IN
F O
R C
IN
G
A N
D C
O V
E R
S E
E
P L A
N A
N D
S E
C T
IO
N
L A
P S
P L
IC
E
S E
E N
O T
E
#6@8
WATERSTOP TYP
approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - SECTION A
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
2. WALL BAR SPLICE LENGTH FOR #8 BAR SHALL BE
96" AND #6 BAR SHALL BE 60".
3. ENGINEERED FILL SHALL BE PLACED AND
COMPACTED IN ACCORDANCE WITH SECTION 6.2
OF THE GEOTECHNICAL INVESTIGATION REPORT.
22 0 4
SCALE: 1/2"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
C L
R C
L R
F O
R R
E
IN
F O
R C
IN
G
A N
D C
O V
E R
S E
E
P L
A N
A N
D S
E C
T
IO
N
CLR
FOR REINFORCING
AND COVER SEE
PLAN AND SECTION
CLR
WALL TO WALL CONSTRUCTION JOINT SECTION
SCALE: 1 1/2"=1'-0"
P
1/31/31/3
#6@8
#8@8
WATERSTOP TYP
L A
P S
P L
IC
E
S E
E N
O T
E
L A
P S
P L
IC
E
S E
E N
O T
E
1/3
FOR REINFORCING
AND COVER SEE
PLAN AND SECTION
1/31/3
3/4" CHAMFER
TYP
WALL CONSTRUCTION JOINT DETAIL
SCALE: 1 1/2"=1'-0"
CJ
CLR CLR
WATERSTOP TYP
18'-0" 18'-0"
2'-0" 4'-0"
STRUCTURAL
BACKFILL
#8@8" DOWELS W/
STD 90° HOOK, TYP
#8@8" T&B
#8@8" T&B
B
SECTION
SCALE: 1/2"=1'-0"
CL
DROP STRUCTURE
OVER EXCAVATE TO EL -191.33 AND REPLACE
WITH 24" LAYER OF ENGINEERED FILL, SEE NOTE 3
BLOCKOUT FOR
STOPLOG SILL
SEE SHEET 23 & 25
8"X6"x8'-6" LONG FLASHBOARD TIMBERS, 6" NOMINAL DIMENSION HORIZONTAL, TYP
TOP OF BOARDS EL -176.05
FLASHBOARD LIFTING DEVICE BY OWNER
#8@8" EF, TYP
2'-0"4'-0"
#5@8"
TIE TO #8 VERT, TYP
3" CLR 4" CLR 3" CLR4" CLR
P
E F
3"
C L R
3"
C L R
TOC
EL -172.8
CONSTRUCTION JOINT
EL -178.55
TOF
EL -187.33
BOF
EL -189.33
EL -191.33
STRUCTURAL
BACKFILL
N
FINISHED GRADE
EL -174.47
ACCESS ROAD
FINISHED GRADE
EL -174.36
FINISH F1
FINISH F1
FINISH F2
FINISHED GRADE
FINISHED GRADE
#8@8" EF, TYP
WATERSTOP TYP
L A
P S
P L
IC
E T
Y P
S E
E N
O T
E
WALKWAY
(BEYOND)
GUARDRAIL (BEYOND)
GUARDRAIL
approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - SECTION B
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
2. WALL BAR SPLICE LENGTH FOR #8 BAR SHALL BE
94" AND #6 BAR SHALL BE 56".
3. ENGINEERED FILL SHALL BE PLACED AND
COMPACTED IN ACCORDANCE WITH SECTION 6.2
OF THE GEOTECHNICAL INVESTIGATION REPORT.
22 0 4
SCALE: 1/2"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at al l t imes.plans shall be available on the project site at al l t imes.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
2'-0" 2'-0"4'-0"4'-0"
TOC FIXED CREST &
DRAIN INV EL -178.55
C
SECTION
SCALE: 1/2"=1'-0"
CL
DROP STRUCTURE
TOC
EL -172.8
TOC
EL -172.8
CONSTRUCTION JOINT
EL -178.55
TOF
EL -187.33
BOF
EL -189.33
EL -191.33
SEE SHEET 20 FOR SUBGRADE
PREPARATION REQUIREMENTS
DRAIN CHANNEL
SECTION
ACCESS ROAD
FINISHED GRADE
EL -174.0
FINISHED GRADE
EL -174.0
CONCRETE FACE
CHANGE IN DIRECTION
GUARDRAIL GUARDRAIL
GUARDRAIL (BEYOND)
FLASHBOARDS
CONCRETE WALL
(BEYOND)
CONCRETE WALL
(BEYOND)
CONCRETE FACE
CHANGE IN DIRECTION
CONCRETE MAT
FOUNDATION
WALKWAY
(BEYOND)
approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - SECTION C
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
22 0 4
SCALE: 1/2"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
26'-0"
2'-0" 2'-0" 10'-6"10'-0"
48" RCP
9"
S T
A
.5
D E
E P
B L O
C K
O U
T
F O
R S
T O
P L O
G S
IL
L
4" CLR3" CLR
E F
C L R
INVERT
NARCISSUS DRAIN
D
SECTION
SCALE: 1/2"=1'-0"
TOC
EL -172.8
ACCESS ROAD (BEYOND)
FINISHED GRADE
EL -173.8
SLOPE 0.3%
CONSTRUCTION JOINT
EL -178.55
STRUCTURAL
BACKFILL
CONSTRUCTION JOINT
EL -178.55
EL -191.33
SEE SHEET 20 FOR SUBGRADE
PREPARATION REQUIREMENTS
TOF
EL -187.33
BOF
EL -189.33
T/O WEIR
EL -176.05
TOC FIXED CREST &
DRAIN INV EL -178.55
D/S FACE OF
FLASHBOARD WEIR
INV EL -186.33
#8@8" EF
#8@8" EF
#5@8"
TIE TO #8 VERT
C L R
1'-6"
#8@8" T&B
4" CLR
#8@8" T&B
E F
#6 ADDITIONAL
ADDITIONAL DIAGONAL
REINFORCEMENT NOT SHOWN.
PLACE IN THIRD LAYER
#8@8" DOWELS W/
STD 90° HOOK, TYP
ROAD CROSSING
FINISHED GRADE
EL -175.5
TOC
EL -172.8
(SEE DETAIL 1 ON SHEET 21)
#5@8"
TIE TO
#8 VERT
FINISH F2
FINISH F2
4" CLR
FINISH F2
FINISH F2
GUARDRAIL
(BEYOND)
WALKWAY
SEE SHEET 26
GUARDRAIL
(BEYOND)
WALL
(BEYOND)
HYDROPHILIC
WATERSTOP
ALL AROUND
135 DEGREE BEND IN WALL
2'-0" approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - SECTION D
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
2. WALL BAR SPLICE LENGTH FOR #8 BAR SHALL BE
94" AND #6 BAR SHALL BE 56".
3. ALL HOOKS ARE STD 90° HOOKS.
22 0 4
SCALE: 1/2"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger
FINISHED GRADE
EL -172.8' (INSIDE)
E F
E
SECTION
SCALE: 1/2"=1'-0"
26'-0"
C L R
EL -191.33
SEE SHEET 20 FOR SUBGRADE
PREPARATION REQUIREMENTS
TOF
EL -187.33
BOF
EL -189.33
C L R
#8@8" T&B
CONSTRUCTION JOINT
EL -178.55
STRUCTURAL
BACKFILL
C L R
T Y
P
#5@8"
TIE TO #8 VERT
TYP
E F
E F
#8@8" EF
#8@8" EF
3" CLR
#8@8" EW T&B
E F
FINISHED GRADE
EL -172.8' (INSIDE)
TOC
EL -172.8
#5@8"
TIE TO #8 VERT
TYP
#8@8" EF
CONSTRUCTION JOINT
EL -178.55
TOF
EL -187.33
BOF
EL -189.33
4" CLR
TYP
F
SECTION
SCALE: 1/2"=1'-0"
EL -191.33
SEE SHEET 20 FOR SUBGRADE
PREPARATION REQUIREMENTS
#8@8" EF
#8@8" EW T&B
#8@8" DOWELS W/
STD 90° HOOK, TYP
#8@8" DOWELS W/
STD 90° HOOK, TYP
TOC
EL -172.8
FINISHED GRADE
EL -176.88
ROAD CROSSING
FINISHED GRADE
EL -175.1
TOC
EL -172.8
4" CLR
TYP, THIS WALL
4" CLR
TYP, THIS WALL
4" CLR
(SEE DETAIL SHEET 21, TYP)
FINISH F1 FINISH F1
FINISH F1
FINISH F1
FINISH F2FINISHED GRADE
EL -174.55
GUARDRAIL GUARDRAIL
WATERSTOP TYP
FINISH F2
approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
DROP STRUCTURE - SECTION E & F
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
2. WALL BAR SPLICE LENGTH FOR #8 BAR SHALL BE
94" AND #6 BAR SHALL BE 56".
3. ALL HOOKS ARE STD 90° HOOKS.
22 0 4
SCALE: 1/2"=1'-0"
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALN
O T A
P P L
IC
A B L E
Approval of this plan does not authorize or approve anyApproval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Finalomission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approvedapproval is subject to field inspection.One set of approved plans shall be available on the project site at all times.plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHALCALIFORNIA STATE FIRE MARSHAL
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
ACCESS COMPLIANCE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
N O T A
P P L
IC
A B L E
IDENTIFICATION STAMPIDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECTDIV. OF THE STATE ARCHITECT
AC FLS SSAC FLS SS
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
N O T A
P P L
IC
A B L E
7/3/2024
3/25/2025
ISSUE DATE: MAY 14, 2025
GGeiger Text Box 03/25/2025
GGeiger
I
3"Ø GROUT ACCESS & VENT HOLE
C6 STOPLOG SILL
DETAIL
SCALE: 3"=1'-0"
STOPLOG SILL &
WALL CNST JT
EL -178.55
/4
TYP
3/16
PLACE NON-SHRINK GROUT AT
STOPLOG SILL CHANNEL PRIOR
TO PLACING WALL CONC ABOVE
CONSTRUCTION JOINT
1/2"Ø SS KWIK BOLT TZ2 W/ 3 1/4" MIN EMBD
INTO FLOOR OF THE BLOCKOUT W/ ADDITIONAL
FENDER WASHERS AND NUTS TOP AND
BOTTOM TO SECURE STOPLOG SILL
PL 3/8x6x0'-7" W/1"Ø HOLE CENTERED
AT THREE LOCATIONS, 3'-0" APART &
CENETERED ON STOPLOG OPENING
3"Ø GROUT ACCESS VENT
HOLE & SILL ANCHORAGE
STOPLOG
SLOT, SYM
TYP
3/16
TYP
4"
3"Ø GROUT ACCESS VENT
HOLE & SILL ANCHORAGE
CL CL
1'-0"
CL
3'-0" SPACING
4'-0"
1"Ø HOLE IN 3/8" PL
FOR SILL ANCHORAGE
TYP
C6
3/16
J
I
SECTION
SCALE: 3"=1'-0"
C6x13x9'-1"
STOPLOG SILL
L5x3x3/8 W/ 1/2"Øx8"@12" OC HEADED CONC
ANCHOR NELSON H4 OR EQUAL, TYP
STOPLOG SILL
EL -178.55
/2
1"
L5x3 3"Ø GROUT ACCESS VENT
HOLE & SILL ANCHORAGE
3"Ø GROUT ACCESS VENT
HOLE & SILL ANCHORAGE
CL CL
STOPLOG
SLOT, SYM
CL
J
SECTION
SCALE: 3"=1'-0"
C6 STOPLOG SILL
DOWNSTREAM FACE OF
FLASHBOARD WEIR
9"
EL -172.8
6"
DETAIL
SCALE: 3"=1'-0"
1'-1"
STOPLOG SILL
EL -178.55
K
TYP @ C6
FLANGES
CNST JT IN WALL
4" DEEP BLOCKOUT
IN WALLS
5 1/2"5 1/2"
B L O
C K
O U
T
EDGE OF WALL
EDGE OF WALL
#5 DOWEL W/ 90° STD HOOK
24" LONG AT12" OC, ORIENT
AS SHOWN, TYP
#5 TIE TO #5 HOOKS AS
SHOWN, EXTEND 24" INTO
WALLS AT EACH END, TYP
C L R
C6X13
K
SECTION
SCALE: 1 1/2"=1'-0"
6"9" 9"
2'-0"
C L R
C L R
#6@8" x 10'-0" LONG
#6@8" EF
#6@8" EF
4" CLR 4" CLR
#8@8" VERT, TYP
#8@8" VERT, TYP
approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
APPROVED
SFM#:
Reviewed by:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
AC FLS SS
DATE
REVISIONS:
DATENO. DESCRIPTION/SHEET NUMBERS
APPROVED
CALIFORNIA STATE FIRE MARSHAL AND DIVISION OF THE STATE ARCHITECT
1 0
SCALE: 3"=1'-0"
FLASHBOARD WEIR - SECTIONS
SCALE: 1 1/2"=1'-0"
0 1
NOTES:
1. FOR GENERAL NOTES AND MATERIAL NOTES SEE
SHEET 18.
2. CONTRACTOR TO FIELD ADJUST REBAR AROUND
WATERSTOP.
& DETAILS
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations. Final approval is subject to field inspection.One set of approved plans shall be available on the project site at all times.
CALIFORNIA STATE FIRE MARSHAL
Approval of this plan does not authorize or approve any omission or deviation f rom applicable regulations.
This is the start of the file's text. The full file is on GovTribe.