Attachment_1_Unit_Submittal.pdf
PDF 377 KB Posted
- Solicitation number
- 12343418Q0003
About this file
Unit Submittal
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Response_to_Questions___Gauley_Office_HVAC_Prequote_notes.docx | DOCX document | |
| SITE_VISIT_ATTENDANCE_SHEET.docx | DOCX document | |
| Amendment_SF30_Gauley_Heat_Pump.pdf | ||
| Location_maps.docx | DOCX document | |
| Pictures.docx | DOCX document | |
| Scope_of_Work_-_Gauley_District_Office_2018.docx | DOCX document | |
| RFQ_Solicitation.Gauley_Heat_Pump.rtf | RTF text file | |
| Attachment_2_Drawing.pdf | ||
| Wage_RatesWV21.txt | TXT text file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094 AAONEcat32 Ver. 4.252 (SN: 5463216-)
A
B
C
D
A
B
C 6 A
B
C
A
B
R N- 009- 8- 0-E6 0S -2F2:B EA C-E0 B- DSD- 0A A-0DKA HB Z-00 -0 0000 00 TB
Tag: AC-1 & 2
Job Name: US Forestry - Richwood, WV Unit Submittal For:
Job Number: 1 Unit Submittal Date: March 03, 2017
Base Option Description
R Series Roof Top Unit
N Generation Ninth Generation
009 Unit Size Nine
8 Voltage 208V/3Ø/60Hz
0 Interior Protection Standard
E Refrigerant Style R-410A VCC - High Efficiency
6 Unit Configuration Air-Source Heat Pump
0 Coil Coating Standard
S Cooling/Heat Pump Staging Modulating Heat Pump + 2 Stage Auxiliary Heat - 1 VCC + 1 On/Off Comp
2 Heating Type Natural Gas Aluminized
F Heating Designation Heat F - 195 MBtuh
2 Heating Staging 2 Stage
Feature Option Description
B 1A. RA/OA Section Economizer + Power Exhaust
E 1B. RA/EA Blower Configuration 1 Blower + Premium Efficiency Motor + 1 VFD
A 1C. RA/EA Blower 12" x 9" Forward Curved
C 1D. RA/EA Blower Motor 1.0 hp - 1760 rpm
E 2. OA Control DDC Actuator
0 3. Heat Options Standard – Aux./Emer. Heating Capacity shown in Heating Designation
B 4. Maintenance Options 115V Convenience Outlet - Factory Wired
D 5A. SA Blower Configuration 1 Blower + Premium Efficiency Motor + 1 VFD
S 5B. SA Blower 22'' Direct Drive Backward Curved Plenum - 70% Width
D 5C. SA Motor 2.0 hp - 1760 rpm
0 6A. Pre Filter Type Standard - None
A 6B. Unit Filter Type 2" Pleated - 30% Eff
A 6C. Filter Options Clogged Filter Switch
0 7. Refrigeration Control Standard - Fixed 55°F Comp. Cooling Lock Out + Adjustable Comp. Heating Lock Out
D 8. Refrigeration Options Modulating Hot Gas Reheat
K 9. Refrigeration Accessories ECM Condenser Fan - Head Pressure Control + Sight Glass
A 10. Power Options Non-fused Disconnect Power Switch - 100 Amps
H 11. Safety Options Remote Safety Shutdown Terminals
B 12. Controls Phase & Brown Out Protection
Z 13. Special Controls Constant Volume (CV) Heat Pump Unit Controller - CV Cool + CV Heat
0 14A. Preheat Configuration Standard - None
0 14B. Preheat Sizing Standard - None
0 15. Glycol Percent Water or No WSHP
0 16. Interior Cabinet Options Standard - Double Wall + R-13 Foam Insulation + Stainless Steel Drain Pan
0 17. Exterior Cabinet Options Standard
0 18. Customer Code Standard
0 19. Code Options Standard - ETL U.S.A. Listing
0 20. Crating Standard
0 21. Water-Cooled Cond. Standard - None
T 22. Control Vendors WattMaster VCB-X Controls + Integrated BACnet MSTP
B 23. Type Standard - Includes AAON Gray Paint
Unit Submittal
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:21 PM
A
B
C
B
C 6 A
B
A
B
Job Information Unit Information
Job Name: Approx. Op./Ship Weights:
Job Number: Supply CFM/ESP:
Site Altitude:
Refrigerant
Final Filter FV / Qty:
Exhaust CFM/ESP/TSP:
Outside CFM:
Ambient Temperature:
Return Temperature:
US Forestry - Richwood, WV 1951 / 1951 lbs. (±5%) 1 3100 / 1.25 in. wg.
0 ft R-410A
223.20 fpm / 4 3100 / 0.25 / 0.44 in. wg.
95 ºF DB / 75 ºF WB
75 ºF DB / 62 ºF WB
Static Pressure
External: Economizer:
Evaporator: Heating:
Filters Clean: Cabinet:
Dirt Allowance Re-Heat Coil:
Total:
1.25 in. wg. 0.12 in. wg.
0.11 in. wg. 0.02 in. wg.
0.04 in. wg. 0.06 in. wg.
0.35 in. wg. 0.02 in. wg.
1.97 in. wg.
Cooling Section Heating Section(**)
Gross Net Total Capacity:
Sensible Capacity:
Latent Capacity:
Mixed Air Temp:
Entering Air Temp:
Lv Air Temp (Coil):
Lv Air Temp (Unit) Digital Comp. Capacity Ratio:
Supply Air Fan:
SA Fan RPM / Width:
Exhaust Air Fan:
EA Fan RPM
Evaporator Coil:
Evaporator Face Velocity:
96.66 92.50 MBH
79.12 74.95 MBH
17.54 MBH
79.00 ºF DB 64.91 ºF WB
79.00 ºF DB 64.91 ºF WB
54.95 ºF DB 54.08 ºF WB
56.18 ºF DB 54.58 ºF WB
100% 1 x 220D70 @ 1.42 BHP 1258 / 3.416" 1 x RM12X9X2 @ 0.64 BHP 728 / 9.000"
14.6 ft² / 3 Rows / 14 FPI
212.6 fpm
Primary Heat Type: Heat Pump - Not operational @
0.0 ºF DB ambient
Auxiliary Heat Type:
Heating CFM:
Total Capacity:
OA Temp:
RA Temp:
Entering Air Temp:
Leaving Air Temp:
Input:
Heater Qty:
Consumption:
Fan Temp Rise:
Nat. Gas Heat
156.0 MBH
0.0 ºF DB / 0.0 ºF WB
68.0 ºF DB / 52.0 ºF WB
54.4 ºF DB / 44.2 ºF WB
101.0 ºF DB / 63.3 ºF WB
195.0 MBH
195.0 MBH
Re-Heat Coil:
Capacity: 57 MBH
LA DB / WB: 72.00 ºF / 60.63 ºF
RH: 52%
Rating Information
Application EER @ Op. Conditions: 10.5
Electrical Data
Rating: Minimum Circuit Amp:
Unit FLA: Maximum Overcurrent:
208/3/60 48 44 60
Qty HP VAC Phase RPM FLA RLA Compressor 1: 1 208 3 16.1 Compressor 2: 1 208 3 13.7 Condenser Fans: 2 0.333 208 1 1110 2.8 Supply Fan: 1 2.00 208 3 1760 7.5 Exhaust Fan: 1 1.00 208 3 1760 4.6 Combustion: 1 0.09 208 1 3010 1.3
Cabinet Sound Power Levels*
Octave Bands: 63 125 250 500 1000 2000 4000 8000 Discharge LW(dB): 86 86 88 79 73 71 68 62 Return LW(dB): 83 80 79 67 66 63 57 48 *Sound power levels are given for informational purposes only. The sound levels are not guaranteed.
(**)Fan motor temperature rise is not included in the heat capacity and temps.
Unit Rating
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:21 PM
A
B
C
B
C 6 A
B
A
B
R N - 0 0 9 - 8 - 0 - E 6 0 S - 2 F 2 : B E A C - E 0 B - D S D - 0 A A - 0 D K A H B Z - 0 0 - 0 0 0 0 0 0 0 T B
Job Information
Job Name: US Forestry - Richwood, WV Job Number: 1
OA CFM: 620 SA CFM: 3100
Performance Data Table
Outside Air Mixed Air Leaving Air Heat Pump Capacity Heat Pump Integrated Capacity
Heating COP
DB ºF WB ºF DB ºF WB ºF DB ºF WB ºF MBH MBH
62.0 56.2 66.8 52.9 102.0 65.8 118.3 118.3 4.32
57.0 51.6 65.8 51.9 98.9 64.4 111.6 111.6 4.19
52.0 47.1 64.8 51.1 96.0 63.1 105.3 105.3 4.07
47.0 42.6 63.8 50.2 93.0 61.7 99.0 99.0 3.93
42.0 38.0 62.8 49.5 90.2 60.5 92.9 92.9 3.80
37.0 33.5 61.8 48.7 83.9 57.9 87.3 75.0 3.17
32.0 28.8 60.8 48.0 81.7 56.8 81.4 71.1 3.10
27.0 24.3 59.8 47.3 79.6 55.8 76.2 67.6 3.02
22.0 19.7 58.8 46.7 77.5 54.8 71.2 64.0 2.94
17.0 15.0 57.8 46.1 75.4 53.8 66.0 60.1 2.84
12.0 10.4 56.8 45.5 73.1 52.8 61.1 56.1 2.72
7.0 5.7 55.8 44.9 * * * * *
2.0 0.1 54.8 44.3 * * * * *
*Invalid operating point - Compressor operating outside of operating envelope.
Unit Rating
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:21 PM
JOB INFORMATION: WHEEL SPECIFICATION:
Job Name: Max RPM:
Job Tag: Diameter x Qty:
Rep Firm: Width%:
Date: Tip Speed:
Inertia:
US Forestry - Richwood, WV 2,200 AC-1 & 2 22.0 in. x 1
03/03/2017 7,246 FPM
5 WR²
OPERATING CONDITIONS: MOTOR SELECTION:
Air Flow: Rated HP / Bypass:
Static Pressure: Frame Size:
Plenum DP: Nominal RPM:
Inlet Grill DP: VAC/PH/HZ:
TSP: Efficiency Site Altitude: Enclosure Type:
TSP @ Sea Level: Max Inertial Load:
3,100 CFM 2 / No
1.97 in. Wg. 145T
0.00 in. Wg. 1760
0.00 in. Wg. 208/3/60
1.97 in. Wg. Premium / 0.865
0.00 Ft ODP
1.97 in. Wg. 27 WR²
FAN PERFORMANCE: FAN SOUND POWER (Inlet/Outlet):
RPM: Octave Band: (Re 10^-12 watts)
BHP: 1 2 3 4 5 6 7 8
Efficiency:
In/Out Velocity:
Plenum Out Velocity: SOUND POWER A-Weighted: 87 / 87 dB
Max Duct SP with Blocked Airway: 2.4 in. Wg. @ 1258 rpm
1.42 68.0% 85 86 88 80 76 74 71 65
948/1044 FPM 85 86 88 80 76 74 71 65
52 FPM
RPM
BHP
SYSTEM
Efficiency
SP Surge
CFM Min
Supply Fan Model: 220D70 @ 1258 RPM and 99% Width Design Conditions: 3100 CFM @ 1.97" SP
CFM x 1000
S P
B H
P
60%
40%
20%
0%
RPM: 1258
BHP: 1.42
EFFICIENCY: 67.97
22.0" STAR Plenum
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:21 PM
JOB INFORMATION: WHEEL SPECIFICATION:
Job Name: Max RPM:
Job Tag: Diameter x Qty:
Rep Firm: CFM:
Date: Tip Speed:
Inertia:
US Forestry - Richwood, WV 1,440 AC-1 & 2 11.0 in. x 1
03/03/2017 2,096 FPM
3 WR²
OPERATING CONDITIONS: MOTOR SELECTION:
Air Flow: Rated HP / Bypass:
Static Pressure: Frame Size:
Relief Dampers DP: Nominal RPM:
VAC/PH/HZ:
TSP: Efficiency Site Altitude: Enclosure Type:
TSP @ Sea Level: Max Inertial Load:
3,100 CFM 1 / No
0.25 in. Wg. 143T
0.19 in. Wg. 1760
208/3/60
0.44 in. Wg. Premium / 0.855
0.00 Ft ODP
0.44 in. Wg. 15 WR²
FAN PERFORMANCE: FAN SOUND POWER (Inlet/Outlet):
RPM: Octave Band: (Re 10^-12 watts)
BHP: 1 2 3 4 5 6 7 8
Efficiency:
In/Out Velocity:
Plenum Out Velocity: SOUND POWER A-Weighted: 80 / 0 dB
0.64 33.8% 79 70 63 64 58 53 48 43
1574/1220 FPM 0 0 0 0 0 0 0 0
52 FPM
RPM
BHP
SYSTEM
Efficiency
SP Surge
CFM Min
Exhaust Fan Model: RM12X9X2 @ 728 RPM and 100% Width Design Conditions: 3100 CFM @ 0.44" SP
CFM x 1000
S P
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
B H
P
40%
20%
0%
RPM: 728
BHP: 0.64
EFFICIENCY: 33.76
12X9X2 FC Fan
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:21 PM
A
B
C
B
C 6 A
B
A
B
Job Name: US Forestry - Richwood, WV VCBX For:
Job Number: 1 VCBX Date: March 03, 2017
Hardware Included For VCBX Controller
Part # Included Parts Assigned Channel BACnet Point V28940 VCBX Controller R82890 Supply Temp Sensor VCBX control point AI2 AI:7 R81550 Outside Temp Sensor VCBX control point AI3 AI:10
Supply Fan 0-10VDC VCBX control point AO1 AI:33 Economizer VCBX control point AO2 AI:32 Safety Shut Down VCBX control point BI1 BI:25
R62330 Proof Of Flow VCBX control point BI2 BI:23 R64580 Dirty Filter Sensor VCBX control point BI3 BI:24 V12960 Defrost Coil Temp Switch VCBX control point BI4 AI:4=8
V12910 Suction Pressure Sensor VCBX EBUS1 communicating sensor AI:19
V09300 Space Temp/Hum (For Cables see controls and accessories)
VCBX EBUS3 communicating sensor AI:6, AI:15
Supply Fan Configured Relay point BI:37 Cooling 1 Configured Relay Point BI:38 Cooling 2 Configured Relay Point BI:39 Condenser Configured Relay Point BI:40 Exhaust Fan Configured Relay Point BI:41 Reversing Valve Configured Relay Point BI:42
V13010 VCBX EXPN EM1
V38410 Discharge Pressure Sensor 2 VCBX expansion point AI4 R37030 Building Pressure Sensor VCBX expansion point AI5 AI:18 V38410 Discharge Pressure Sensor 1 VCBX expansion point AI6 AI:20
Building Pressure Control VCBX expansion point AO1 AI:36 ECM Condender Fan Pwm Sig VCBX expansion PWM output AI:39 Heat 1 Configured Relay Point BI:43 Heat 2 Configured Relay Point BI:44
VCBX Components
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:22 PM
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:22 PM
Date Created/Modified: 3/3/2017 3:35:15 PM Using Ver 4.252 (OSN# 0123456) Date Printed: 3/3/2017 3:35:22 PM
File details come from the government source that posted it.