This document is a design contract for the Reservoir South Embankment Rehabilitation project at the Stuttgart National Aquaculture Research Center (SNARC) in Stuttgart, Arkansas, administered by the U.S. Department of Agriculture Agricultural Research Service (USDA ARS). The contract number is 12405B21D0003, with Design Order No. 12405B23F0294.

The project scope involves rehabilitation of the south embankment of a reservoir facility through excavation of materials from the reservoir bottom and reuse of reclaimed materials as fill to raise and restore levee embankments to specified side slopes. Key construction activities include: draining the reservoir (government responsibility with contractor coordination); providing silt fencing and erosion control measures; scarifying and aerating soils for minimum five days without measurable rainfall; removing and preparing subgrades; placing reclaimed material in compacted lifts with maximum six-inch layer thickness; installing geotextile fabric; placing 18-inch R200 rip rap slope protection; installing three-inch crushed aggregate surfacing compacted to 95 percent maximum density per ASTM D698; and mulching and seeding all disturbed areas to establish minimum 95 percent turf coverage of actively growing vegetation one inch or taller. The design drawings specify the overall site plan, south embankment sections at multiple stations (0+50.00 through 12+00.00), typical new levee sections with rip rap and geotextile details, silt fence specifications, and embankment surface profiles. The project includes coordination with existing facilities including research ponds, pumphouses, pump sheds, deep wells, and drainage infrastructure that must be protected in place.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET NO.

INDEX OF DRAWINGS

TITLE

T-001 C-100 C-200 C-300

COVER SHEET

OVERALL SITE PLAN

SOUTH EMBANKMENT SECTIONS

TYPICAL DETAILS USDA

NO SCALEVICINITY MAP

NORTH

PROJECT

LOCATION

RUSSELLVILLE CONWAY

SEARCY

HOT SPRINGS STUTTGART

PINE BLUFF

FAYETTEVILLE

EL DORADO

FORT

SMITH

LOCKESBURG

TEXARKANA

LITTLE ROCK

DRAWING NO.

LOCATION MAP NO SCALE

NORTH

YODER

ALMYRA

153130

SNARC PROJECT

LOCATION

ARKANSAS

U.S. DEPARTMENT OF AGRICULTURE

AGRICULTURAL RESEARCH SERVICE

RESERVOIR SOUTH EMBANKMENT REHABILITATION

DESIGN CONTRACT NO: 12405B21D0003

DESIGN ORDER NO: 12405B23F0294

STUTTGART NATIONAL AQUACULTURE RESEARCH CENTER (SNARC)

STUTTGART, AR

GENERAL NOTE:

THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO PERFORMING WORK, FABRICATION OR PURCHASE OF ANY EQUIPMENT, MATERIALS, AND ASSEMBLIES. ANY DISCREPANCIES SHALL BE BROUGHT TO THE CONTRACTING OFFICER'S ATTENTION FOR RESOLUTION BEFORE PROCEEDING

WITH ANY CONSTRUCTION, FABRICATION, OR EQUIPMENT PURCHASE.

PPM

REVISIONS

Agricultural

Service Research

DESCRIPTION

SHEET

DATEc P.A.

FIRM

U

NO.

DEPM

SAFETY & HEALTH

REAL PROPERTY

A

DATE

PROJECT NO.

SUSDA

BY

AGRICULTURAL RESEARCH SERVICE

OF

THE

DESIGNER

PROJECT MANAGER

JOB #

CHECKED BY

A-E FIRM

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

Johnson M Adams

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

J:\ Gr ee nw oo d\G wd Da ta\

Jo bs \58

-E

U

SD

A Po nd S tab iliz ati on

F loo d S tud y -

S tut tga rt\

S ub mi tta ls\

P1 D

- S ou th\ Dr aw ing s\R

AW

\T -0

.dw g N ov

, 2

5 - 3:

pm

USDA AGRICULTURAL RESEARCH SERVICE

STUTTGART NATIONAL AQUACULTURE

RESEARCH CENTER

RESERVOIR SOUTH EMBANKMENT REHABILITATION

COVER SHEET

T-001 1 410/8/25

THT

JMD

DRL USDA ARS

141 EXPERIMENT STATION ROAD

STONEVILLE MS 38776

5823-E

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EO

P

EOP EOP EOP EOP

EOP

EOP

EO

P

EO

P

EO

P

EO

P

0'

150'

SCALE:

SITE PLAN

1" = 100'-0"

C-100

SCALE:1"=100'-0"

0 100'100' 50'

B18

B17

B16

B15

B14

B13

B12

B11

B10

B9

B8

B7

B6

B5

B4

B3

B2

B1

D18

D17

D16

D15

D14

D13

D12

D11

D10

D9

D8

D7

D6

D5

D4

D3

D2

D1 E1

E2

E3

E4

E5

E6

E7

E8

E9

PUMPHOUSE #1

(B12)

PUMPHOUSE #2

DEEP WELL (WATER SUPPLY

FOR FISH HATCHERY)

PUMP SHED

C18

C17

C16

C15

C14

C13

C12

C11

C10

C9

C8

C7

C6

C5

C4

C3

C2

C1

A18

A17

A16

A15

A14

A13

A12

A11

A10

A9

A8

A7

A6

A5

A4

A3

A2

A1

POND DRAINS

3A

BUNKERS

MAIN

OFFICE 1

1A

9A

DEEP WELL

(WATER SUPPLY

FOR PONDS)

APHIS

SEPTIC SAND FILTER BED

A15

EOP

LEGEND:

RESEARCH POND IDENTIFIER

BUILDING/STRUCTURE

DRAINAGE DITCH

EXISTING OVERHEAD POWER

CULVERT

STATE HIGHWAY IDENTIFIER

HAUL / ACCESS ROUTE

RESERVOIR

NORTH

EAST RESERVOIR LEVEE

C-200

LOADED TRUCK ENTRANCE

UNLOADED TRUCK EXIT

CONTRACTOR LAY

DOWN AREA.

PROVIDE SILT

FENCE PERIMETER.

SCOPE OF WORK & CONSTRUCTION SEQUENCE

1. THE GOVERNMENT IS RESPONSIBLE FOR DRAINING THE RESERVOIR TO FACILITATE EXCAVATION OF MATERIALS FROM THE

RESERVOIR BOTTOM. THE CONTRACTOR SHALL USE RECLAIMED MATERIALS FROM THE RESERVOIR BOTTOM AS FILL MATERIAL TO RAISE THE LEVEE EMBANKMENTS AND RE-ESTABLISH SIDE SLOPES AS INDICATED.

1.1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING RESERVOIR DRAINING WITH GOVERNMENT PERSONNEL.

THIS INCLUDES OBTAINING AND ABIDING BY ANY / ALL APPLICABLE LOCAL, STATE, AND / OR FEDERAL PERMITTING

FOR DRAINING THE RESERVOIR.

2. PROVIDE AND INSTALL SILT FENCING AND ANY OTHER REQUIRED EROSION CONTROL MEASURES.

3. SCARIFY SOILS TO BE RECLAIMED AND USED AS FILL MATERIAL AND ALLOW TO AERATE AND DRY A MINIMUM OF 5 DAYS

WITHOUT MEASURABLE RAINFALL BEFORE PLACING AS FILL AND COMPACTING.

4. REMOVE TOPSOILS OVER AREAS TO RECEIVE FILL. SCARIFY, AERATE, AND ALLOW SUBGRADE TO DRY A MINIMUM OF 5 DAYS

WITHOUT MEASURABLE RAINFALL BEFORE PLACING FILL.

5. PLACE RECLAIMED MATERIAL AS FILL AND COMPACT IN LIFTS AS REQUIRED. AREAS OUTSIDE OF THOSE TO RECEIVE

CRUSHED AGGREGATE SURFACING SHALL BE SEMI-COMPACTED AS DEFINED BELOW:

5.1. MAXIMUM LAYER THICKNESS BEFORE COMPACTION SHALL BE 6 INCHES. COMPACTION SHALL BE ACCOPMPLISHED BY ROUTING THE HAULING AND SPREADING EQUIPMENT OVER THE FILL IN SUCH A MANNER THAT EVERY POINT OF THE SURFACE OF EACH LAYER OF FILL WILL BE TRAVERSED NO LESS TWICE BY ONE TREAD TRACK OF THE EQUIPMENT

OR OTHER METHODS APPROVED BY THE CONTRACTING OFFICER'S REPRESENTAITVE.

6. PLACE TOPSOILS OVER AREAS NOT TO RECEIVE RIP RAP OR CRUSHED AGGREGATE SURFACING.

7. PROVIDE AND INSTALL GEOTEXTILE FABRIC AS INDICATED PRIOR TO RIP RAP INSTALLATION.

8. PROVIDE AND INSTALL RIP RAP SLOPE PROTECTION AS INDICATED.

9. PROVIDE, PLACE, AND COMPACT EMBANKMENT CRUSHED AGGREGATE SURFACING AS INDICATED.

10. REMOVE SILT FENCE AND OTHER EROSION CONTROL DEVICES.

11. MULCH AND SEED ALL DISTURBED AREAS. WATER AS REQUIRED TO ESTABLISH A TURF STAND (MIN. 95% COVERAGE OF

ACTIVELY GROWING GRASS / VEGETATION 1” OR TALLER).

PPM

REVISIONS

Agricultural

Service Research

DESCRIPTION

SHEET

DATEc P.A.

FIRM

U

NO.

DEPM

SAFETY & HEALTH

REAL PROPERTY

A

DATE

PROJECT NO.

SUSDA

BY

AGRICULTURAL RESEARCH SERVICE

OF

THE

DESIGNER

PROJECT MANAGER

JOB #

CHECKED BY

A-E FIRM

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

Johnson M Adams

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

J:\ Gr ee nw oo d\G wd Da ta\

Jo bs \58

-E

US

DA

Po nd

St ab iliz ati on

Flo od

St ud y - St utt ga rt\0 8 S ub mi tta ls\P

1D

- S ou th\

Dr aw ing s\R

AW

\C-

0.d wg O ct

, 2

5 -

:25 am

USDA AGRICULTURAL RESEARCH SERVICE

STUTTGART NATIONAL AQUACULTURE

RESEARCH CENTER

RESERVOIR SOUTH EMBANKMENT REHABILITATION

OVERALL SITE PLAN

C-100 2 410/8/25

THT

JMD

DRL USDA ARS

141 EXPERIMENT STATION ROAD

0+50

1+00

2+00

3+00

4+00

5+00

6+00

7+00

7+50

8+00

9+00

10+00 11+00

12+00

1+00.00

3+00.00

2+00.00

4+00.00

0+50.00

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

6+00.00

7+00.00

8+00.00

9+00.00

5+00.00

7+50.00

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

9+00.00

10+00.00

11+00.00

12+00.00

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

-50 -40 -30 -20 -10 0 10

20'

SCALE: 1"=10'-0"

0 10' 30'

30'60' 60'0

SCALE:1"=60'-0"

NORTH

SCALE:

RESERVOIR SOUTH EMBANKMENT

1" = 60'

C-200

SCALE:

SOUTH EMBANKMENT SECTIONS

HORI.: 1" = 10' VERTI.: 1" = 10'

C-200

LEGEND EXISTING THIS CONTRACT

MAJOR CONTOUR

MINOR CONTOUR

EMBANKMENT FILL MATERIAL

NEW EMBANKMENT SURFACE PROFILE

EXISTING EMBANKMENT SURFACE PROFILE

LIMITS OF RIP RAP SLOPE PROTECTION

EXISTING FACILITIES

SILT FENCE

R200 RIP RAP

GENERAL NOTES

1. FOR DRAWING CLARITY AGGREGATE ROADWAY SURFACING NOT SHOWN

THIS SHEET. SEE 1/C-300 FOR TYPICAL NEW LEVEE SECTION SHOWING

AGGREGATE ROADWAY SURFACING, RIPRAP KEY, AND SLOPE DETAIL.

2. GRADE ALL DISTURBED AREAS TO DRAIN, SEED, AND ESTABLISH TURF

STAND.

3. ALL EXISTING STRUCTURES TO BE PROTECTED IN PLACE.

SF

ALIGNMENT ORIGIN

STA.: 0+00

N: 1970149.39 E: 1489757.43

ALIGNMENT TERMINUS

STA.: 12+35.7

N: 1969898.32 E: 1490799.86

RESERVOIR

EDGE OF EXISTING

EMBANKMENT

CROWN

CONTINUE PROVISION OF LEVEE

SECTION SHOWN IN 12+00 SO

AS TO PROVIDE A SEAMLESS

TRANSITION IN EMBANKMENT

PROFILE, GRADES, AND SLOPE

PROTECTION FROM THE

SOUTHERN TO THE EASTERN

EMBANKMENT.

PPM

REVISIONS

Agricultural

Service Research

DESCRIPTION

SHEET

DATE

U

NO.

DEPM

SAFETY & HEALTH

REAL PROPERTY

A

DATE

PROJECT NO.

SUSDA

BY

AGRICULTURAL RESEARCH SERVICE

OF

DESIGNER

PROJECT MANAGER

JOB #

CHECKED BY

A-E FIRM

J:\ Gr ee nw oo d\G wd Da ta\

Jo bs \58

-E

U

SD

A Po nd S tab iliz ati on

F loo d S tud y -

S tut tga rt\

S ub mi tta ls\

P1 D

- S ou th\ Dr aw ing s\R

AW

\C -2

.dw g O ct

, 2

5 -

:26 am

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

Johnson M Adams

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

P.A.

FIRMTHE c

USDA AGRICULTURAL RESEARCH SERVICE

STUTTGART NATIONAL AQUACULTURE

RESEARCH CENTER

RESERVOIR SOUTH EMBANKMENT REHABILITATION

SOUTH EMBANKMENT SECTIONS

C-200 3 410/8/25

THT

JMD

DRL USDA ARS

141 EXPERIMENT STATION ROAD

STONEVILLE MS 38776

5823-E

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.8' 16' MIN.

CONTINUE PROVISION OF LEVEE

SECTION SHOWN IN 0+50 SO AS

TO PROVIDE A SEAMLESS

TRANSITION IN EMBANKMENT

PROFILE, GRADES, AND SLOPE

PROTECTION FROM THE

SOUTHERN TO THE WESTERN

EMBANKMENT.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.8' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.8' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.8' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.4' 16' MIN. 18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.3' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.5' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.7' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.5' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

202.6' 16' MIN. 18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

201.5' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

200.9' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

201.2' 16' MIN.

18" R200 RIP RAP OVER

GEOTEXTILE FABRIC.

201.0' 16' MIN.

ALIGNMENT PI

N: 1970179.21 E:1490533.86 R:50.03

ALIGNMENT PI

N: 1969907.85 E:1490596.02

R:45.88

SF SF SF SF SF

SF

SF

SF

SF

SF

SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF

SIDE ELEVATION

COMPACTED SOIL

FRONT ELEVATION

VARIABLE

6" MIN.

VARIABLE

(10'-0" MAX. OR AS DIRECTED BY THE ENGINEER)

LINE WIRES (MIN.

12 1/2 GAGE)

2'- 0"

M

IN

3'-

0"

3'- 0"

MI

N.

W

ID

TH

GE

OT

EX

TI

LE

FA

BR

IC

6" 2'-

2"

GEOTEXTILE FABRIC IN 6" X 6"

TRENCH. BACKFILL WITH SOIL AND COMPACT.

NOTES:

1. WIRE MUST BE MINIMUM OF 32" IN WIDTH AND MUST HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING.

2. GEOTEXTILE FABRIC MUST BE A MINIMUM OF 36" IN WIDTH AND MUST BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE ENGINEER.

3. STEEL POST MUST BE 5'-0" IN HEIGHT AND OF THE SELF-FASTENER ANGLE STEEL TYPE. WOOD POST MUST BE A MINIMUM OF 5'-0" IN HEIGHT AND

3" OR MORE IN DIAMETER. WIRE FENCE MUST BE FASTENED TO WOODEN POST WITH NOT LESS THAN 9 GAGE WIRE STAPLES 1" LONG.

4. GEOTEXTILE FABRIC MEETING THE TYPE II MATERIAL REQUIREMENTS AND INSTALLED ACCORDING TO SPECIFICATIONS MAY BE USED WITHOUT

WIRE FENCE.

X

X

X

X

X

X

XX

X

X

X

X

X 1'

1'

6"

1'

3'

1'- 6"

MUDLINE EL.: VARIES

ELEVATION VARIES

R200 RIP RAP

GEOTEXTILE FABRIC

AS SPECIFIED. PROVIDE 24"

OVERLAP AT SEAMS.

GEOTEXTILE FABRIC KEY

WITH COMPACTED BACKFILL

SCALE:

TYPICAL SILT FENCE DETAIL

N.T.S.

C-300

SCALE:

TYPICAL NEW LEVEE SECTION

N.T.S.

C-300

VARIES

IN-SITU SOILS, TYP.

EDGE OF EXISTING CROWN OF EMBANKMENT

FOR AREAS BENEATH CRUSHED

AGGREGATE SURFACING, PROVIDE 8"

OF SOIL (EXISTING OR FILL AS

REQUIRED) COMPACTED TO AT LEAST

95% OF MAXIMUM DENSITY AS

DETERMINED BY ASTM D698.

3" ARDOT CLASS 7 CRUSHED AGGREGATE SURFACING

COMPACTED TO AT LEAST 95% OF MAXIMUM

DENSITY AS DETERMINED BY ASTM D698.

16' MIN.

FOR FILL AREAS BENEATH RIP RAP, PLACE

AND SEMI-COMPACT DRIED MATERIAL

OBTAINED FROM RESERVOIR BOTTOM. SEE

GENERAL NOTES AND SPECIFICATIONS FOR

DRYING AND COMPACTION REQUIREMENTS.

EXISTING EMBANKMENT FORESLOPE FOR

RESEARCH PONDS

PPM

REVISIONS

Agricultural

Service Research

DESCRIPTION

SHEET

DATEc P.A.

FIRM

U

NO.

DEPM

SAFETY & HEALTH

REAL PROPERTY

A

DATE

PROJECT NO.

SUSDA

BY

AGRICULTURAL RESEARCH SERVICE

OF

THE

DESIGNER

PROJECT MANAGER

JOB #

CHECKED BY

A-E FIRM

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

Johnson M Adams

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

J:\ Gr ee nw oo d\G wd Da ta\

Jo bs \58

-E

US

DA

Po nd

St ab iliz ati on

Flo od

St ud y - St utt ga rt\0 8 S ub mi tta ls\P

1D

- S ou th\

Dr aw ing s\R

AW

\C-

0.d wg O ct

, 2

5 -

:26 am

USDA AGRICULTURAL RESEARCH SERVICE

STUTTGART NATIONAL AQUACULTURE

RESEARCH CENTER

RESERVOIR SOUTH EMBANKMENT REHABILITATION

TYPICAL DETAILS

C-300 4 410/8/25

THT

JMD

DRL USDA ARS