This is a Questions and Answers document (Amendment 5) for RFQ# 1232SA26Q0361 issued by USDA for the removal of a walk-in cooler located in room B1-SB36 at a facility in Athens, Georgia.
The document clarifies critical project specifications and scope details. The walk-in cooler has rough dimensions of 23 feet by 21 feet; manufacturer and model information are unknown. The removal scope includes associated compressor and condenser equipment, with supply lines to be capped with sufficient length for future connection. Fire sprinkler disconnects are not required; sprinklers should remain undisturbed in the space. The correct room location is B1-SB36 (not SB46 as referenced in some solicitation documents). No architectural plans, drawings, or floor plans are available for this project. The government requires complete removal of all equipment from the concrete floor to the steel decking and from the East wall to the West wall. Additionally, the West wall dividing B1-SB36 and B1-SB35 must be constructed with steel studs extending from the concrete floor to the steel decking, fully insulated, covered with 5/8-inch sheet rock on both sides, and finished with fire tape and mud. Photographs of the existing walk-in cooler space are included to provide visual reference for potential bidders.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment 5
RFQ# 1232SA26Q0361 - Remove Walk-in Cooler located in B1, SB46 (Athens, GA)
Questions and Answers:
1. Would USDA be able to provide:
• Dimensions of the existing walk-in cooler Answer: the rough dimensions are 23’x 21’
• Manufacturer/model information (if available) Answer: Unknown.
• Photos of the existing unit:
Answer: see below
• Confirmation whether associated compressor/condenser equipment is included in the removal scope
Answer: Yes, we would like them removed with the supply lines capped with enough length to make a future connection.
• Confirmation whether fire sprinkler disconnects are required Answer: Disconnects are not required. Simply leave the fire sprinklers where they are in the space. Undisturbed if possible.
• Clarification on room location (solicitation references SB46 while the SOW references SB36) Answer: The correct room number is B1-SB36.
• Any available drawings/layout information
Answer: There are no drawings. The government requires everything removed from the concrete floor to the steel decking and from the East wall to the West wall. The West wall (dividing B1-SB36 and B1-SB35) shall be built with steel studs from the concrete floor to the steel decking, insulated throughout, covered with 5/8 sheet rock on both sides, and fire taped and mudded.
2. The revised Statement of Work references work to be performed in accordance with project requirements, drawings, and applicable codes. We did not see a separate plan sheet, floor plan, sketch, or drawing file included in the solicitation attachments. Could you please confirm whether any plans, drawings, sketches, or room layout documents are available for this requirement?
a. ANSWER: There are no plans or drawings for this project.
3. Confirm whether the correct room number is B1, SB46 or B1, SB36, since both references appear in the solicitation documents.
a. ANSWER: The correct room number is B1-SB36