Requirement specifications 1232SA25Q0539.pdf
PDF 83 KB Posted
- Attached to
- Maxwell RSC System and Glomax Explorer - Davis, CA Federal contract opportunity
- Solicitation number
- 1232SA25Q0539
About this file
This document is a solicitation with detailed specifications for two scientific research instruments: the Maxwell RSC System automated purification instrument and the GloMax® Explorer System instrument. The Maxwell RSC System specifications require an automated nucleic acid extraction instrument capable of processing 1-16 samples per run, with broad sample type compatibility (including blood, serum, plasma, tissues, and wastewater), paramagnetic particle separation, compact design, and heated elution. The GloMax® Explorer System specifications call for a microplate assay instrument with integration with Promega protocols, a 9-log luminescence dynamic range, support for Dual Luciferase and NanoLuc Assays, and capabilities to read 6-384 well plate formats. Both instruments require global technical support and a one-year warranty. Delivery is specified as FOB to USDA/ARS at 3026 Bee Biology Rd., Davis, CA 95616, indicating this is a federal procurement for scientific research equipment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Clauses and Provisions_1232SA25Q0539 amd 0001.pdf | ||
| Requirement specifications 1232SA25Q0539.pdf | ||
| Combined Synopsis Solicitation_1232SA25Q0539.pdf | ||
| Solicitation Clauses and Provisions_1232SA25Q0539.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications – The “equal” item in accordance with the “Brand Name or Equal” of this solicitation must meet or exceed the following characteristics:
Minimum Requirement specifications – (1) Maxwell RSC System automated purification instrument - Brand name or Equal
The following requirements are essential to conduct mission critical research involving automated nucleic acid extractions and processing
• Automated purification of nucleic acids for use in PCR and NGS applications, isolated from a broad range of sample types, including blood, serum, plasma, viral transport media, cells, animal and plant tissues, formalin fixed and paraƯin embedded (FFPE) tissues, fecal samples, swabs, saliva, and wastewater samples
• sample lysis and binding to paramagnetic particles as the primary separation principle
• Machine must be compact to fit a small work space
• Utilization of a low elution volume format for sample processing allowing for maximum nucleic acid
• Automated processing of 1 to 16 samples per purification run
• Heated elution to improve yields
• Pre-filled reagent cartridges
• Pre-loaded extraction protocols associated for each sample type
• Global Instrument and Reagent Support by Technical Services
• One Year Warranty on Parts and Labor from date of purchase
Minimum Requirement specifications – (1) GloMax® Explorer System instrument specs
- Brand name or Equal
The following requirements are essential to conduct mission critical research involving microplate assays:
• Integration with Promega assay protocols, pre-loaded and ready to use out of the box
• Performance surpassing most dedicated single-mode instruments for luminescence, fluorescence, or UVVisible absorbance assays.
• Tablet PC and software interface providing simple navigation and a wide variety of data export options.
• Luminescence dynamic range of 9 logs without the use of filters or gain changes. Superior sensitivity with detection of 3 x 10-21 moles of luciferase using Luciferase Assay Reagent
• suitable for Dual Luciferase Assays (DLReady™) and NanoLuc Assays (NanoLuc™ Ready).
• Upgradable capabilities for UV and Visible absorbance, BRET, and FRET detection modes.
• Automatic data analysis.
• Configured with a factory-installed shaker that allows either linear or orbital shaking, as well as temperature control.
• Reads 6, 12, 24, 48, 96, and 384-well plate formats.
• Global Instrument and Reagent Support by Technical Services
Delivery must be FOB to USDA/ARS 3026 Bee Biology Rd., Davis, CA 95616