14.Exhibit J Inspection Checklists.pdf
PDF 2 MB Posted
- Solicitation number
- 1204N020Q0002
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 1.pdf | ||
| 5.Exhibit A PPE.doc | DOC document | |
| 11.Exhibit G ODF Interagency Firefighting Crew Agreement.pdf | ||
| 6.Exhibit B Training.doc | DOC document | |
| 1.Solicitation.doc | DOC document | |
| 2.Fire Clauses.pdf | ||
| 8.Exhibit D Engine Types.docx | DOCX document | |
| 9.Exhibit E Skidgens.docx | DOCX document | |
| 3.Wage Determination.pdf | ||
| 15.Exhibit K BPA Call Sample Template.doc | DOC document | |
| 13.Exhibit I OF-297_Emergency_Equipment_Shift_Ticket-fillable.pdf | ||
| 10.Exhibit F Dozers Excavators.docx | DOCX document | |
| 4.EQUIPMENT CLEANING form.doc | DOC document | |
| 7.Exhibit C Tenders.docx | DOCX document | |
| 12.Exhibit H Hand Crew Manifest.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
Equipment Inspection Checklist – RX Burn, Suppression Repair/BAER BPA NOV 2019
TRANSPORT INSPECTION CHECKLIST Date: Time:
PROJECT NAME:
COMPANY/CONTRACTOR:
EQUIPMENT MAKE: MODEL:
VIN/SERIAL #:
OPERATOR NAME:
EQUIPMENT and OPERATOR REQUIREMENTS --TRANSPORT
Type 1: Rated at loads over 70,000 lbs Type 2: Rated at loads 35,001-- 69,999 lbs Type 3: Rated at loads up to 35,000lbs
Minimum Requirements Yes No
1 Check-In Process Completed
2 RT-130 Fire Line Refresher including Fire Shelter (current):
Completed Date:
3 OF-296 Vehicle/Heavy Equipment Pre-use Inspection Checklist completed
4 Equipment arrived at project washed: (Debris and noxious weeds free)
5 Insurance: Current and valid carrier insurance and cargo insurance with types of cargo being hauled
6 Current Dept. of Transportation D.O.T. Certification
7 Seat belts
8 Flashlight
9 Water: At least 1 gallon drinking water
10 First aid kit: 10 person minimum
11 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection Headlamp with batteries
12 Fire Shelter: New generation
13 Flame Resistant Clothing: A minimum of two full sets of flame resistant shirt and pants certified to NFPA 1977 standard.
14 Shovel
15 *Spark Arrester if applicable Not Applicable Turbo Exhaust
16 Back-Up Alarm: Audible reverse warning device.
17 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the operator and with current annual inspection tag
18 Tire Tread Depth: minimum 2/32” for rear 4/32” for steering axle tires
Equipment Inspection Checklist – RX Burn, Suppression Repair/BAER BPA NOV 2019
Equipment meets agreement specifications Equipment does not meet agreement specifications
Inspector: Date:
(Print and sign)
Contractor:
Date:
Contractor given the opportunity to correct noted deficiencies (See Remarks)
Contactor successfully corrected noted deficiencies
REMARKS:
TRANSPORT INSPECTION CHECKLIST
Date:
REMARKS:
RX Burn, Supp. Repair and BAER BPA BACKHOE INSPECTION FORM NOV 2019
INSTALLED EQUIPMENT
CAB/ OROPS A/C 4X4 / 4X2
E-STICK GP/ MP BUCKET BUCKET SIZE
LOADER QC BACKHOE QC BACKHOE BUCKET
FRT AUX HYDS THUMB HAMMER
REAR AUX HYDS FORKS PILOT CONTROLS
COMP WHEEL PLATE COMP BROOM
OTHER:
CONDITION (E) EXCELLENT (G) GOOD (P) POOR
OPERATORS COMPARTMENT E G P NOTES
ROPS STRUCTURE INTEGRITY
CAB CONDITION OVERALL
STEERING WHEEL / COLUMN
SEAT CONDITION / OPERATION
SEAT BELT / ARMREST
INSTRUMENT GAUGES
INTERIOR LIGHTS
BACK UP ALARM
GLASS / WINDOWS OPERATION
REAR WINDOW OPERATION
DOOR (OPERATION/ HANDLES)
FLOOR MAT/ HEADLINER
WINDSHIELD WIPERS
HEATER/ AC
FANS/ VENTS
CAB CONTROLS
HORN/ STEREO
LOADER CONTROLS
BACKHOE CONTROLS
OPERATORS MANUAL
INSPECTOR:
LOCATION:
DATE OF INSPECTION: YEAR:
MAKE:
MODEL:
SERIAL NUMBER:
HOUR (METER):
TOTAL HOURS:
COSMETIC / EXTERIOR E G P NOTES
PLATFORMS
STEPS / GRAB IRON
FENDERS
HOOD CONDITION (OPEN/CLOSE)
PAINT/ DECALS
INSPECTION/ ENGINE DOORS
FRONT/ REAR LIGHTS
STRUCTURAL E G P NOTES
STRUCTURAL DAMAGE
FRAME CRACKS
BOOM/ STICK DAMAGE/ CRACKS
BOOM/ STICK PINS
BOOM/ STICK CYLINDER PINS
EXTENDABLE STICK CONDITION
LOADER BUCKET PINS
LOADER LIFT/ TILT PINS
LIFT CYLINDER PINS
BUCKET TILT LINK/ PINS
FRONT AXLE ARTICULATION PIN
LOADER QC CONDITION
BACKHOE QC CONDITION
OUTRIGGER CONDITION
OUTRIGGER PAD TYPE/ CONDITION
HYDRAULICS E G P NOTES
OIL LEVEL
PUMP NOISE / LEAKS
TANK
AUX VALVE/ LINES
VALVES
STEERING OPERATION
LIFT CYLINDERS
TILT CYLINDERS
LINE/ HOSE CONDITION
BOOM SWING CYLINDERS
BOOM/ STICK/ BUCKET CYLINDERS
EXTENDABLE STICK HYDS
OUTRIGGER CYLINDERS/ LINES
STEERING/ LIFT CYLINDERS
BACKHOE BUCKET E G P NOTES
BUCKET TYPE / SIZE
BUCKET MAKE
BUCKET OVERALL CONDITION
BUCKET TYPE / SIZE
BUCKET MAKE
BACKHOE ATTACHMENT TYPE
BACKHOE ATTACHMENT MAKE
ATTACHMENT CONDITION
LOADER BUCKET / ATTACHMENTS E G P NOTES
BUCKET MAKE / MODEL SIZE
BUCKET FLOOR
BUCKET EDGE
CUTTING EDGE/ TOOTH
LOADER ATTACHMENT TYPE
LOADER ATTACHMENT MAKE
LOADER ATTACHMENT CONDITION
HYDRAULICS E G P NOTES
OIL LEVEL
PUMP NOISE / LEAKS
TANK
AUX VALVE/ LINES
VALVES
STEERING OPERATION
LIFT CYLINDERS
TILT CYLINDERS
LINE/ HOSE CONDITION
BOOM SWING CYLINDERS
BOOM/ STICK/ BUCKET CYLINDERS
EXTENDABLE STICK HYDS
OUTRIGGER CYLINDERS/ LINES
STEERING/ LIFT CYLINDERS
CONDITION (E) EXCELLENT (G) GOOD (P) POOR
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER
NOV 2019
DOZER INSPECTION CHECKLIST Date: Time:
EQUIPMENT and OPERATOR REQUIREMENTS – DOZER
Type 1: 200+ HP Type 2: 100 → 199 HP Type 3: 50 → 99 HP
2 RT-130 Fire Line Refresher including Fire Shelter: Date:
4 Equipment arrived at project washed: (Debris and noxious weeds free) )
5 Backup Alarm
6 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the operator and with current annual inspection tag
7 Shovel
8 Flashlight
9 Water: (At least 1 gallon drinking water)
10 First aid kit: (10 person minimum)
11 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection
12 Fire Shelter: (New generation)
13 Flame Resistant Clothing: (Two full sets)
Operator Protection System installed, such as; Forestry cab with wire mesh or safety glazing providing equal protection (polycarbonate windows) and deflectors. Protection for operator on sides, top (canopy) and rear of dozer
15 Lighting: (2 lights forward, 2 lights rear. Lights provide illumination beyond the blade)
16 All factory guards in place and functional (i.e. engine compartment)
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER NOV 2019
Minimum Requirements (continued) Yes No 17 ROPS: Manufacturer’s nameplate or documentation certifying the operator’s enclosure meets ISO or
SAE safety requirements
18 Cab, rear: The rear portion of the cab shall be fully enclosed with open mesh material with openings such size as to reject the entrance of an object larger than 2 inches in diameter
19 *Seat Belts
20 *Spark Arrester (Not Applicable: Turbo exhaust)
21 Radiator Protection
22 Underbody protection: (belly pan, rock guards unless not recommended by manufacture)
Optional Equipment
23 6-Way Hydraulic Blade
24 282+ Flywheel Horsepower
25 Winch:
26 Ripper:
27 Grapple:
28 Low Ground Pressure:
*Item may be waived if inspection successfully performed on the OF-296.
Equipment meets specifications Equipment does not meet specifications
Contractor:
RX Burn, Supp Repair & BAER BPA Dump Truck Inspection Checklist NOV 2019
Date: Project:
Equipment ID Number: Mileage Hours:
Power On Items Cab 1st Aid Kit/Fire Ext.
Warning Triangles Seat Belts WS/Windows Wipers/Washers Horn (Air & Electric) Mirrors Reg. sticker/Inspection Fire Extinguisher
Brakes Emergency brake Operation
Bed Ladder Cover/tarp Loose Cargo Dump bed safety bar Bed Lock Lamp Lift Cylinder & Pin Tailgate Latch Bed Up Limit Cable
Lamps Head/Dimmer Parking Turn Signal Four Way Clearance Lamps Tail Lamps Reverse Lamps/Alarm License Lamp
√ = Condition safe for operation X = Discrepancy discovered
(X) = Discrepancy repaired
Comments:
Operator's Printed Name & Signature Date
Power Off Items Walk Around Leaks (fluid/air) General Condition
Under Hood Oil level Transmission Fluid Brake/PTO Fluid Power Steering Fluid Coolant/Radiator Belts Hoses Air Cleaner
Battery Cable Condition Mountings/Hold Down Cover Secured
Tires Tread/Match Tire Condition Tire PSI Wheel/Lugnuts
Side Lamps Marker Lamps Reflectors Conspicuity
Hydraulics Reservoir Level PTO Operation Hose Condition Cylinder Condition Leaks
Frame/Suspension Loose bolts Cracks Springs/U‐bolts Mud flaps
Air Brakes Air Press. Buzzer & Lamp Tank‐Drain Air Test/Brake on/off Slack Adjuster Glad‐hands/hoses
RX Burn, Supp Repair & BAER BPA Dump Truck Inspection Checklist NOV 2019
Comments:
RX Burn/ Suppression Repair/BAER BPA - Equipment Inspection Checklist NOV 2019
ENGINE INSPECTION CHECKLIST Date: Time:
VIN #: Tank Capacity (Gallons):
OPERATOR NAME: CDL LICENSE: NO YES Endorsements:
EQUIPMENT and PERSONNEL REQUIREMENTS – WILDLAND FIRE ENGINE
Type 3 Type 4 Type 5 Type 6
RT-130 Fire Line Refresher including Fire Shelter (current):
Completed Dates: ENGB FFT1/2 FFT1/2
Engine Staffing / Personnel: Minimum of 3 crew members (unless otherwise ordered and documented) . All crew members have valid and current qualification cards and government pictured I.D.
Engine Boss (Name):
FFT1 / FFT2 (Name):
Additional Personnel; see remarks
6 Company Name and Unique Identification #: Affixed to both sides of truck cab
7 Type 6 Engine, All-wheel drive (Type 3,4,5 engines all-wheel drive optional)
8 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the
9 2 Wheel chocks
10 *Reflective Triangles, bi-directional, set of 3
11 *Seat Belts: for all passengers
RX Burn/ Suppression Repair/BAER BPA - Equipment Inspection Checklist
12 Back-Up Alarm: in accordance with SAE J994; 87 decibels, and 2 back up lights
13 Tires: All season or mud and snow tires. 4x4’s must have mud and snow tires on all wheels, tire tread depth of a minimum of 2/32” for rear tires and 4/32” for steering axle tires
14 Spare Tire: Full size spare tire, spare is securely mounted to vehicle. Has adequate tire changing equipment
15 1 Gallon Container for drinking water
16 1 – First Aid Kit (10 person minimum)
17 Programmable Radios: Minimum of 2. One must be Handheld. Two fully charged battery packs per radio, and one programming cable
18 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection
19 Flame Resistant Clothing: A minimum of two full sets of flame resistant shirt and pants certified to NFPA 1977 standard (per crewmember)
20 Fire Shelter: New generation
21 3 – Line Gear (Day Packs): Min. of one per crew member
All Inventory Permanently Engraved: Required to permanently mark their equipment inventory with vendor/company information. Acceptable markings shall be etched or engraved. Painting or marking the equipment with permanent markers is not acceptable. In addition, the vendor is to maintain a complete inventory list, including any extra items they may be carrying
23 1 – Live reel with minimum of 100’ hose, non-collapsible ¾” inside diameter
24 1” Hose (see table for min. quantity)
25 1 ½ ” Hose (see table for min. quantity)
26 ¾” Hose (see table for min. quantity)
27 2 Nozzles, combination Fog/Straight Stream, 1” NH female
28 2 Nozzles, combination Fog/Straight Stream, 1 ½” NPSH female
29 2 Nozzles, adjustable ¾ inch (garden hose)
30 20’ Suction hose with strainer or screened foot valve
31 3 – Shovels, size “0”
32 3 – Pulaski’s
33 1 – Forestry, Fire Hose Clamp
34 4 – Spanner wrenches, combination, 2 ea. 1” & 1 ½”
35 1 – Double Male 1 ½” NH
36 1– Double Female 1 ½” NH
37 1 – Double Male 1” NPSH
38 1 – Double Female 1” NPSH
39 2 – Gated Wyes, 1 ½” NH
40 2 – Gated Wyes 1” NPSH
41 1 – Gated Wye ¾” (garden hose)
42 4 – Reducers, 1 ½” NH Female to 1” NPSH Male
43 1 – Reducer 1” NPSH to ¾” Garden Hose
44 2 – Adapters 1 ½” NH Female to 1 ½” NPSH Male
45 2 – Adapters 1 ½” NPSH Female to 1 ½” NH Male
46 1 - Mop Up Wand, ¾ inch receptor, with ¾ inch nozzle tip:
47 5 – Inline Ball Valves ¾”
48 2 – Backpack pumps
49 10 – Fusee’s (fire starter)
50 3 – Mill Bastard Files
51 1 Chainsaw with fuel (3.0 cubic in. min w/18” bar, chaps, hearing protection gas/oil, and accessories (OSHA Approved Fuel Containers)
52 Auxiliary pump (if equipped) w/spark arrester: Min. 12 Hours fuel.
53 Pump starts and pumps min. 250 psi (T3) 100 psi (T4,5,6)
54 Pump Discharge Pressure Gauge
55 Pump and Roll capable
56 Foam Proportioner System: All Engines shall be equipped with a foam proportioner system Manually Regulated Automatically Regulating
57 Foam: Minimum of 5 gallons
58 1 ea. 1 ½” discharge valve full flow, rapid shut off
59 Water Tank: Firmly attached to frame or structurally sound flatbed
Tank meets baffling requirements One longitudinal baffle and one transverse baffle every 52” OR free floating baffle system with data sheet that validates baffling is sufficient to meet manufacturer’s recommendation.
Pump Accessories (If Pump Powered by Auxiliary Engine) 61 Wrench, Adjustable 10”
62 Wrench, Spark Plug (Unless adjustable wrench is suitable)
63 1 Pliers (Slip Joint)
64 2 Quarts Crankcase Oil
65 1 Screwdriver (Standard Blade)
66 1 Screwdriver (Phillips)
67 1 Spare Starter Rope (if required)
68 1 Grease Gun (with grease)
69 Spark Plugs (Sufficient to replace all plugs on auxiliary pump) (Optional/Attributes)
Contractor: Date:
70 Compressed Air Foam System (CAFS)
Wildland Fire Engine Requirements
STRUCTURE
ENGINES
WILDLAND
ENGINES
Components 1 2 3 4 5 6 7 Pump Rating minimum flow (gpm) 1000+ 500+ 150 50 50 50 10 at rated pressure (psi) 150 150 250 100 100 100 100
Tank Capacity Range (gal) 300+ 300+ 500+ 750+ 400–750 150–400 50–200 Hose (feet)
2-1/2 inch 1200 1000 ~ ~ ~ ~ ~ 1-1/2 inch 500 500 1000 300 300 300 ~ 1 inch ~ ~ 500 300 300 300 200
Ladders (ft) 48 48 ~ ~ ~ ~ ~ Master Stream (GPM) 500 ~ ~ ~ ~ ~ ~ Personnel (minimum) 4 3 3 2 2 2 2
CHAINSAW and CHAINSAW KIT INSPECTION CHECKLIST (Wildland Engines Only)
MANUFACTURER:
MODEL NUMBER:
SERIAL NUMBER:
CHAINSAW ( Minimum Engine Power required is 3.0 cubic inches) Yes No
Any Visible Parts Broken
All visible nuts and bolts tight
Oil in chain reservoir
Proper Exhaust System and spark arrester
Started and checked the engine: Idles evenly, runs smoothly, satisfactory power
Guide Bar: Minimum of 18 inches, not bent, or damaged
Pull / Starter Rope: Functions properly
Chain Brake: Functions properly
CHAINSAW KIT
1 Chainsaw Kit: Bag or box to store complement
1 Wrench: Combination; bar and sparkplug wrench
1 Spark Plug: Spare spark plug that works (fits) in saw
1 pint Engine Oil (2 stroke/cycle mix)
1 pair Chaps: Wrap around leg safety chaps – OSHA approved
1 Chain: Extra chain to fit saw-bar combo
1 Chain File: Appropriate size for chain on saw
1 Felling Axe
1 Felling Wedge
1 Fuel container: OSHA approved fuel container to hold chainsaw fuel and guide bar oil.
Properly secured on vehicle.
2 pair Ear Plugs
Note: Contractor is required to have both the chainsaw and OSHA approved container(s) full of proper fuel mixture and oil at time of inspection.
EQUIPMENT and PERSONNEL REQUIREMENTS – WILDLAND FIRE ENGINE
Minimum Requirements (continued) Yes No
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER BPA NOV 2019
EXCAVATOR INSPECTION CHECKLIST Date: Time:
EQUIPMENTMAKE: MODEL:
EQUIPMENT and OPERATOR REQUIREMENTS – EXCAVATOR
Type 1: 156+ HP Type 2: 111 → 155 HP Type 3: 81 → 110 HP Type 4: 60 → 80 HP
4 Equipment arrived at incident washed: (Debris and noxious weeds free)
5 Back-Up Alarm:
Cab: Factory or aftermarket enclosed cab constructed to OSHA standards at the time of manufacture. Must protect operator from injury due to falling trees, limbs, saplings or branches which might enter the compartment side areas and from snapping winch lines or other objects.
Deflectors: Installed in front of the operator area to deflect whipping saplings and branches. Deflectors shall be located so as not to impede visibility and access to the cab (may be part of the cab)
8 Operator Protection: Protective screen or bars over the front of the cab acting as a deflector of brush and branches.
9 All factory guards in place and functional (i.e. engine compartment)
10 Radiator Protection
11 Underbody protection: Unless not recommended by manufacturer. (i.e. belly pan, rock guards)
12 *Spark Arrester (Not Applicable: Turbo exhaust)
13 *Seat Belts
14 Steel Tracks
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER
Minimum Requirements – continued Yes No 15 Lighting: (2 lights forward, both work. Mounted to the equipment in such a way to provide protection from damage and provide illumination beyond the bucket/thumb)
16 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the
17 Water: (At least 1 gallon drinking water)
18 First aid kit: (10 person minimum)
19 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection
20 Fire Shelter: New generation
21 Flame Resistant Clothing: A minimum of two full sets of flame resistant shirt and pants certified to NFPA 1977 standard.
22 Shovel
23 Flashlight Optional Equipment
24 Clamshell Bucket
25 Up Down Blade or Dozer Blade
26 Steep Ground Excavator (note: self-leveling cab)
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER BPA NOV 2019
Front End Loader Pre-use Inspection Checklist PROJECT NAME: Make & Model:
Company: Hour Meter Reading:
VIN# Date:
POWER OFF CHECKS
OK
NO
N/A
POWER ON CHECKS
OK
NO
N/A
1) Underneath machine: 11) Unit starts and runs properly
a) Wheels & Tires 12) Instruments/Gauges
b) Axles 13) Hour Meter
2) Lights/Strobes 14) Warning lights/audible alarms
3) Mirrors/Visibility aids 15) Fuel level
4) Engine/Engine compartment: 16) Horn/audible warning device(s)
a) Belts/Hoses 17) Function controls:
b) Cables/Wires a) Drive – forward/reverse
c) Debris b) Steer – left/right
5) Battery/Batteries: c) Bucket/Attachment – All movements
a) Terminals tight d) Accessories
b) Clean/Dry/Secure 18) Emergency/auxiliary controls
6) Hydraulics: 19) Wipers
a) Cylinders/Rods 20) Seatbelt inspected & fastened
b) Hoses/Lines/Fittings GENERAL OK NO N/A
c) Pins/Locks 21) Equipment arrived at the project washed
7) Fluids: 22) Manufacturer's operating manuals
a) Engine oil Level Leaks 23) Decals/Warnings/Placards
b) Engine coolant Level Leaks 24) Misc. parts – loose/missing/broken
c) Hydraulic oil Level Leaks
d) Fuel/Battery Level Leaks
8) Chassis:
a) Cab/Glass/Doors
b) Emergency Exit
c) Entry/exit steps
d) ROPS/FOPS
e) Counterweight/Counterweight bolt(s)
f) Fire Extinguisher/Suppression System
g) Articulated frame lock present/functional
9) Digging Assembly:
a) Bucket & cutting edge/work attachment
b) Loader arms & pins
10) Other:
Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER BPA
ROAD GRADER INSPECTION CHECKLIST Date: Time
PROJECT NAME: ___________________________________________
EQUIPMENT MAKE:
MODEL: VIN/SERIAL#:
Type 1: 165+ HP Type 2: 120-164 HP
EQUIPMENT and OPERATOR REQUIREMENTS – ROAD GRADER
2 RT-130 Annual Fire Line Refresher including Fire Shelter
5 12 foot Mold Board (Minimum)
6 Cab: Factory installed cab with ROPS
7 Lighting (Min. 2 rear, 2 forward)
8 PPE: Boots Hard Had ( Hardhat meeting NFPA Standard 1977) Gloves Headlamp with batteries Hearing Protection Eye Protection
9 Fire Shelter: New Generation
10 Tire Chains: not required to be mounted but must be available for use within the next operational period.
NOV 2019 Equipment Inspection Checklist - RX Burn/Suppression Repair/BAER BPA
SKIDGEN INSPECTION CHECKLIST Date: Time:
VIN/SERIAL #: VEHICLE I.D. #:
EQUIPMENT and OPERATOR REQUIREMENTS SKIDGEN
Type 1: Type 2: Type 3: Type 4:
(see table below for minimum requirements)
Vehicle Identification: All equipment shall have the company’s name and unique identification number affixed to the transport vehicle (not the piece of equipment). The company name and unique ID shall be on each Side of the cab.
6 Machines manufactured after Aug. 1, 1996 ROPS meeting SAE J1040 and FOPS meeting SAE J231 is required
7 Machines manufactured after Aug. 1, 1996 Fully enclosed cab with wire mesh or safety glazing required
Machines manufactured before Aug. 1, 1996 Protective canopy is constructed to protect the operator from injury due to falling trees, limbs, saplings or branches which might enter the compartment side areas and from snapping winch lines or other objects
Lower portion of the cab is fully enclosed with solid material, except at entrances, to prevent the operator from being injured from obstacles entering the cab
Equipment Inspection Checklist NOV 2019
Upper rear portion of the cab fully enclosed with open mesh material with openings of such size as to reject the entrance of an object larger than 2 inches in diameter
Open mesh extended forward as far as possible from the rear corners of the cab sides so as to give the maximum protection against obstacles, branches, etc., entering the cab area
12 Cab: Each machine shall have a second means of egress.
13 Tank: Securely attached to the chassis. Fiberglass or plastic tanks must be surrounded by steel to prevent puncture damage
14 Fill Pipe: 4 inch minimum
15 Dump Valve: 3 inch minimum. Capable of dumping into a port-a-tank
16 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the operator and with current annual inspection tag
17 Flashlight 18 Water: At least 1 gallon drinking water 19 First aid kit: 10 person minimum
20 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection Headlamp with batteries
21 Fire Shelter: New generation
22 Flame Resistant Clothing: A minimum of two full sets of flame-resistant shirt and pants certified to NFPA 1977 standard.
Equipment Inventory
Inventory: Permanently mark their equipment inventory with vendor/company information. Acceptable markings shall be etched or engraved. Painting or marking the equipment with permanent markers is not acceptable.
24 Hose Reel: Operational, minimum 150 feet of 1 inch hard line hose with ¾” inside diameter
25 Hose, 1 ½ inch: 300 ft (Type 1 and 2 ONLY) 26 Hose, 1 inch: 300 ft (Type 1 and 2) 200 ft (Type 3 and 4) 27 1 Shovel 28 1 Pulaski 29 1 Hose Clamp: Forestry type 30 1 Spanner Wrench: Combination 1 inch to 2 inch 31 2 Nozzles: Combination fog / straight stream, 1 inch NPSH Female 32 1 Fitting: Double Male, 1 inch NPSH 33 1 Fitting: Double Female, 1 inch NPSH 34 1 Reducer: 1 ½ inch NH Female to 1 inch NPSH Male 35 1 Reducer: 1 inch NPSH to ¾ inch (garden hose) 36 1 Adapter: 1 inch NH Female to 1 inch NPSH Male 37 1 Adapter: 1 inch NPSH Female to 1 inch NH Male
38 Pump Type Auxiliary Power Take Off (PTO)
39 Auxiliary pump (if equipped): Fuel to operate pump, minimum 5 gallons and pump accessories (i.e. Pliers, Oil, Screwdrivers etc.)
40 Pump: Discharge Pressure Gauge
41 Pump: 20 foot suction hose
42 Discharge Outlet: 1 inch NPSH
Lighting: Minimum 2 rear, 2 forward Operational, lights must be mounted to the equipment in such a way to provide illumination beyond the blade or working area
44 Back-Up Alarm: 87 decibel Optional Items
45 Winch or Grapple: Operable
46 Foam Proportioner System: Manual Automatic
47 Compressed Air Foam System:
48 Drop Tank Skidgen: Type 3 or 4 only and must also have a grapple
SKIDGINE
REQUIREMENTS TYPE 1 TYPE 2 TYPE 3 TYPE 4
Tank Capacity (gallons) Minimum Maximum
1,200
NONE
1,199
Pump Min Flow (gpm) @ rated pressure (psi)
1” hard line with ¾” inside diameter hose on reel
150 feet
1 ½ inch linen hose 300 feet 300 feet - - 1 inch linen hose 300 feet 300 feet 200 feet 200 feet Discharge Outlet 1 ½ inch NH 1 ½ inch NH 1 inch NPSH 1 inch NPSH Pump and Roll Yes Yes Yes Yes Foam Proportioner System Optional Optional Optional Optional
Winch Not required Not required Optional Optional Grapple Not required Not required Optional Optional Drop tank with Grapple Optional Optional Optional Optional Personnel Required 1 1 1 1
EQUIPMENT and OPERATOR REQUIREMENTS SKIDGEN
SKIDGINE
Equipment Inspection Checklist - RX Burn/ Suppression Repair/BAER BPA NOV 2019
SUPPORT WATER TENDER INSPECTION CHECKLIST Date: Time:
EQUIPMENT MAKE: MODEL: YEAR:
VIN #:
OPERATOR NAME: Driver’s License#
State _________Expiration date:_ Class: Endorsements:
EQUIPMENT and OPERATOR REQUIREMENTS SUPPORT WATER TENDER
Type 1: 4,000+ gallons Type 2: 2,500 → 3,999 gallons Type 3: 1,000 → 2,499 gallons
2 Annual Fire Line Safety Refresher Training including Fire Shelter (current)
5 Annual DOT/Commercial Vehicle Safety Alliance (CVSA) Inspection certification
DOT# CVSA#
6 Brakes on all axles.
All vehicles 36,000 GVWR or greater shall be installed with an operator-controlled auxiliary braking system in addition to the service brakes (i.e., engine retarder, transmission retarder, driveline retarder, or exhaust retarder)
8 Company Name and Equipment I.D. #: Permanently affixed to both sides of truck
9 Seat Belts: For all passengers
10 Reflective Triangles, Bi-directional, set of 3
11 Programmable Radio: At least 2 fully charged battery packs per radio
12 First aid kit: 10 person minimum
13 Flashlight
14 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the operator and with current annual inspection tag
15 PPE: Boots Hard Hat
Gloves Eye Protection Hearing Protection
16 Fire Shelter: New generation
Equipment Inspection Checklist - RX Burn/ Suppression Repair/BAER BPA
17 Flame Resistant Clothing (Shirt and Pants): Minimum of two Full Sets
Equipment Inventory: Permanently marked with vendor/company identification.
Markings should be etched or engraved, painting or marking with permanent markers is not acceptable
19 Inventory List: Maintain a complete inventory list, including any extra items they may be carrying
20 1 - Nozzle combination Fog/Strait Stream (1 ½ NH female)
21 1 - Reducer, 1 ½ inch NH female to 1 inch NPSH male
22 2 - Reducers 2 ½ inch NH female to 1 ½ inch NH male
23 2 - Adapters 1 ½ inch NPSH female to 1 ½ inch NH male
24 2 - Adapters 1 ½ inch NH female to 1 ½ inch NPSH male
25 1 - Double male 1 ½ inch NH
26 1 - Double Female 1 ½ inch NH
27 1 - Gated “Y” 1 ½ NH
28 1 - Fire Hose Clamp 2 ½ inch
29 1 - Spanner Wrench, Combination 1 ½ inch to 2 ½ inch
30 1 - Adjustable Hydrant Wrench
31 1 - Shovel – Size 0 or 1
32 1 - Pulaski
33 100 foot – 1 ½ inch Cotton/Synthetic Hose NH thread
34 50 Foot – 2 ½ inch Cotton/Synthetic Hose NH thread
35 Suction hose with strainer or screened foot valve: 20 foot minimum
36 1 - 2 ½ inch Discharge Outlet, NH thread
37 2 - 1 ½ inch Discharge Outlet, NH thread
38 Wheel Chocks: At least one pair, meeting specifications
Tank Baffling: (1) longitudinal baffle regardless of width and one (1) transverse baffle. The distance between vertical tank walls and baffles, or between parallel baffles, shall not exceed 52”.
Free Floating Baffle System (Baffle Balls) Note: Vendor must have data sheets which validates that the baffling is sufficient to meet the manufacturers recommendation.
40 Dump Valve: Minimum 4 inch, extends past rear of vehicle
41 Pump Discharge Pressure Gauge
42 Auxiliary pump (if equipped): Fuel to operate for at least 12 Hours
43 Spray Bar Configuration: Front Rear Both Gravity Pressure
44 Tire Tread Depth: Minimum 2/32” for rear and 4/32” for steering axle tires
45 Back-Up Alarm
Equipment Inspection Checklist - RX Burn/ Suppression Repair/BAER BPA
TACTICAL WATER TENDER-- INSPECTION CHECKLIST Date: Time:
EQUIPMENT MAKE: _ MODEL: _
LICENSE PLATE, State and #:
EQUIPMENT and PERSONNEL REQUIREMENTS – TACTICAL WATER TENDER
Type 1 2000+ gallons Type 2 1000-1999 gallons
2 Check-In Process Completed
3 Equipment VIN/Serial #
4 RT-130 Fire Line Refresher including Fire Shelter (current):
5 OF-296 Vehicle/Heavy Equipment Pre-use Inspection Checklist completed
6 Equipment arrived at incident washed: (Debris and noxious weeds free)
Staffing / Personnel: Minimum of 2 crew members. All crew members have valid and current qualification cards and government pictured I.D.
FFT1 (Name):
Additional Personnel; see remarks
6 Brakes on all axles
All vehicles 36,000 GVWR or greater shall be installed with an operator-controlled auxiliary braking system in addition to the service brakes (i.e., engine retarder, transmission retarder, driveline retarder, or exhaust retarder)
8 Company Name, Equipment I.D. # and DOT #: Affixed to both sides of truck cab
9 Programmable Radios: Minimum One Handheld. Also has two battery clamshells
10 Fire Extinguisher: 2A 10BC, securely mounted to the vehicle, accessible to the operator and with current annual inspection tag
11 Wheel Chocks: 2 Each
12 Audible reverse warning device (backup alarm)
13 First Aid Kit, 10 person minimum
14 Flashlight
15 *Seat Belts
16 Line Gear (I.A. Gear / Day Pack): Minimum of one per crew member
17 PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection
18 Flame Resistant Clothing: A minimum of two full sets of flame resistant shirt and pants certified to NFPA 1977 standard.
19 Tank: shall be firmly attached to chassis frame or structurally sound flat bed
Tank Baffling: (1) longitudinal baffle regardless of width and one (1) transverse baffle. The distance between vertical tank walls and baffles, or between parallel baffles, shall not exceed 52”.
Free Floating Baffle System (Baffle Balls) Note: Vendor must have data sheets which validates that the baffling is sufficient to meet the manufacturers recommendation.
Minimum Inventory
Equipment Inventory: Permanently marked with vendor/company identification.
Markings should be etched or engraved, painting or marking with permanent markers is not acceptable, in addition the vendor is to maintain a complete inventory list.
22 1 - Live Hose reel 100’ non-collapsible w/3/4” inside diameter
23 1 - Nozzle, combination Fog/Straight Stream, 1 ½ NH female
24 1 – Nozzle, Class A Foam, 1 ½” NH Female, min. 20 GPM at 100 PSI
25 2 - Shovels
26 2 - Pulaski’s
27 1 - Spanner Wrench, combination 1 inch to 1 ½ inch
28 1 - Adjustable Hydrant wrench
29 2 - Adapters, 1 ½ inch NH female to 1 ½ inch NPSH male
30 2 - Adapters, 1 ½ inch NPSH female to 1 ½ inch NH male
31 2 - Reducers, 2 ½ inch NH female to 1 ½ inch NH male
32 1 - Reducer, 1 ½ inch NH female to 1” inch NPSH male
33 1 – Double Male 1 ½” NH
34 1 – Double Female 1 ½” NH
35 1 – Gate Y 1 ½” NH
36 1 – Fire Hose Clamp 2 ½”
37 200’ 1 ½” cotton/synthetic hose NH thread
38 50” 2 ½” cotton/synthetic hose NH thread
39 10 – Fusee’s (Fire starter)
40 All Pumps shall have a discharge pressure gauge
41 Pump: Pump Type Auxiliary or Power Take Off (PTO)
42 20’ Suction Hose, with strainer or screened foot valve
43 Foam Proportioner System:
44 Foam: Minimum 5 gallons
45 Monitor: Manual Remote None *Item may be waived if inspection successfully performed on the OF-296
Spray Bar head(s) operational:
Spray Bar Configuration: Front Rear Both Gravity Pressure
47 1 – 2 ½” Discharge outlet NH thread
48 2 – 1 ½” Discharge outlet NH thread
49 4” Gravity Dump valve on rear of tank
50 2 ½” Valve at bottom of tank with NH threads
51 Full size spare tire: With minimum of 4/32 tread and wheel securely mounted to the vehicle. The spare tire shall be easily accessible
Optional Attributes 52 All-Wheel Drive